Edible offal of pigs, fresh, chilled or frozen · Process: Sanitation and wastewater management (sanitation_and_wastewater_management)
Edible offal of pigs, fresh, chilled or frozen · Process: Sanitation and wastewater management (sanitation_and_wastewater_management): Record sodium hydroxide as one…
- Lifecycle status
- Candidate
- Content maturity
- Authored methodology
- Current version
- No published version
- Readiness
- Review required
- Last updated
Methodology and translation states come from the source record; publishing this website does not change their review status.
Content languages
Status, classification and source details
Readiness
- Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.
Classification mapping
Source
Process: Sanitation and wastewater management (sanitation_and_wastewater_management)
Inputs
Product flows
sodium hydroxide input (sanitation_and_wastewater_management_sodium_hydroxide)
Record sodium hydroxide as one formulation-identity input from chemical issue or dosing records; do not aggregate it with another substance.
- Selected flow: Sodium hydroxide
- Flow property / unit: Mass / kg
- Amount rule: Measured formulated-product mass of sodium hydroxide used for cleaning, disinfection or treatment; record active concentration separately in the protocol fields.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_and_wastewater_management_chemical_dosing_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
nitric acid input (sanitation_and_wastewater_management_nitric_acid)
Record nitric acid as one formulation-identity input from chemical issue or dosing records; do not aggregate it with another substance.
- Selected flow: Nitric acid
- Flow property / unit: Mass / kg
- Amount rule: Measured formulated-product mass of nitric acid used for cleaning, disinfection or treatment; record active concentration separately in the protocol fields.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_and_wastewater_management_chemical_dosing_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
sodium hypochlorite input (sanitation_and_wastewater_management_sodium_hypochlorite)
Record sodium hypochlorite as one formulation-identity input from chemical issue or dosing records; do not aggregate it with another substance.
- Selected flow: Sodium hypochlorite
- Flow property / unit: Mass / kg
- Amount rule: Measured formulated-product mass of sodium hypochlorite used for cleaning, disinfection or treatment; record active concentration separately in the protocol fields.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_and_wastewater_management_chemical_dosing_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
peracetic acid input (sanitation_and_wastewater_management_peracetic_acid)
Record peracetic acid as one formulation-identity input from chemical issue or dosing records; do not aggregate it with another substance.
- Selected flow: Peracetic acid
- Flow property / unit: Mass / kg
- Amount rule: Measured formulated-product mass of peracetic acid used for cleaning, disinfection or treatment; record active concentration separately in the protocol fields.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_and_wastewater_management_chemical_dosing_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
hydrogen peroxide input (sanitation_and_wastewater_management_hydrogen_peroxide)
Record hydrogen peroxide as one formulation-identity input from chemical issue or dosing records; do not aggregate it with another substance.
- Selected flow: Hydrogen peroxide
- Flow property / unit: Mass / kg
- Amount rule: Measured formulated-product mass of hydrogen peroxide used for cleaning, disinfection or treatment; record active concentration separately in the protocol fields.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_and_wastewater_management_chemical_dosing_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
chlorine dioxide input (sanitation_and_wastewater_management_chlorine_dioxide)
Record chlorine dioxide as one formulation-identity input from chemical issue or dosing records; do not aggregate it with another substance.
- Selected flow: Chlorine dioxide
- Flow property / unit: Mass / kg
- Amount rule: Measured formulated-product mass of chlorine dioxide used for cleaning, disinfection or treatment; record active concentration separately in the protocol fields.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_and_wastewater_management_chemical_dosing_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
ferric chloride input (sanitation_and_wastewater_management_ferric_chloride)
Record ferric chloride as one formulation-identity input from chemical issue or dosing records; do not aggregate it with another substance.
- Selected flow: Ferric chloride
- Flow property / unit: Mass / kg
- Amount rule: Measured formulated-product mass of ferric chloride used for cleaning, disinfection or treatment; record active concentration separately in the protocol fields.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_and_wastewater_management_chemical_dosing_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
calcium hydroxide input (sanitation_and_wastewater_management_calcium_hydroxide)
Record calcium hydroxide as one formulation-identity input from chemical issue or dosing records; do not aggregate it with another substance.
- Selected flow: Calcium hydroxide
- Flow property / unit: Mass / kg
- Amount rule: Measured formulated-product mass of calcium hydroxide used for cleaning, disinfection or treatment; record active concentration separately in the protocol fields.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_and_wastewater_management_chemical_dosing_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
polyacrylamide flocculant input (sanitation_and_wastewater_management_polyacrylamide_flocculant)
Record polyacrylamide flocculant as one formulation-identity input from chemical issue or dosing records; do not aggregate it with another substance.
- Selected flow: Polyacrylamide flocculant
- Flow property / unit: Mass / kg
- Amount rule: Measured formulated-product mass of polyacrylamide flocculant used for cleaning, disinfection or treatment; record active concentration separately in the protocol fields.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_and_wastewater_management_chemical_dosing_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Sanitation and wastewater management potable mains water (sanitation_and_wastewater_management_potable_mains_water)
Record only potable mains water delivered to sanitation and wastewater management as a separately metered product input.
- Selected flow: Potable mains water
- Flow property / unit: Volume / m3
- Amount rule: Metered mains-water volume attributable to this stage; no category default is permitted.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_and_wastewater_management_water_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Sanitation and wastewater management grid electricity (sanitation_and_wastewater_management_grid_electricity)
Record grid electricity crossing the facility boundary and consumed specifically by sanitation and wastewater management; keep this carrier separate from every other carrier.
- Selected flow: Electricity, medium voltage, grid mix
- Flow property / unit: Energy / kWh
- Amount rule: Metered, invoiced or stock-balanced grid electricity attributable to this stage; no default is permitted.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_and_wastewater_management_electricity_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Sanitation and wastewater management purchased steam (sanitation_and_wastewater_management_purchased_steam)
Record purchased steam crossing the facility boundary and consumed specifically by sanitation and wastewater management; keep this carrier separate from every other carrier.
- Selected flow: Purchased steam
- Flow property / unit: Energy / MJ
- Amount rule: Metered, invoiced or stock-balanced purchased steam attributable to this stage; no default is permitted.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_and_wastewater_management_thermal_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Sanitation and wastewater management purchased hot water (sanitation_and_wastewater_management_purchased_hot_water)
Record purchased hot water crossing the facility boundary and consumed specifically by sanitation and wastewater management; keep this carrier separate from every other carrier.
- Selected flow: Purchased hot water
- Flow property / unit: Energy / MJ
- Amount rule: Metered, invoiced or stock-balanced purchased hot water attributable to this stage; no default is permitted.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_and_wastewater_management_thermal_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Sanitation and wastewater management natural gas (sanitation_and_wastewater_management_natural_gas)
Record natural gas crossing the facility boundary and consumed specifically by sanitation and wastewater management; keep this carrier separate from every other carrier.
- Selected flow: Natural gas
- Flow property / unit: Energy / MJ
- Amount rule: Metered, invoiced or stock-balanced natural gas attributable to this stage; no default is permitted.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_and_wastewater_management_fuel_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Sanitation and wastewater management diesel fuel (sanitation_and_wastewater_management_diesel_fuel)
Record diesel fuel crossing the facility boundary and consumed specifically by sanitation and wastewater management; keep this carrier separate from every other carrier.
- Selected flow: Diesel fuel
- Flow property / unit: Mass / kg
- Amount rule: Metered, invoiced or stock-balanced diesel fuel attributable to this stage; no default is permitted.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_and_wastewater_management_fuel_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Sanitation and wastewater management liquefied petroleum gas (sanitation_and_wastewater_management_liquefied_petroleum_gas)
Record liquefied petroleum gas crossing the facility boundary and consumed specifically by sanitation and wastewater management; keep this carrier separate from every other carrier.
- Selected flow: Liquefied petroleum gas
- Flow property / unit: Mass / kg
- Amount rule: Metered, invoiced or stock-balanced liquefied petroleum gas attributable to this stage; no default is permitted.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_and_wastewater_management_fuel_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Waste flows
Pig-slaughter wastewater entering wastewater management (sanitation_and_wastewater_management_pig_slaughter_wastewater)
Record this source-separated wastewater only when the corresponding process branch is included and the stream enters on-site management.
- Selected flow: Pig-slaughter wastewater
- Flow property / unit: Volume / m3
- Amount rule: Transferred wastewater volume reconciled to the originating process records.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_and_wastewater_management_wastewater_balance_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Pig-organ-preparation wastewater entering wastewater management (sanitation_and_wastewater_management_pig_organ_preparation_wastewater)
Record this source-separated wastewater only when the corresponding process branch is included and the stream enters on-site management.
- Selected flow: Pig-organ-preparation wastewater
- Flow property / unit: Volume / m3
- Amount rule: Transferred wastewater volume reconciled to the originating process records.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_and_wastewater_management_wastewater_balance_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Fresh-pig-organ-conditioning wastewater entering wastewater management (sanitation_and_wastewater_management_fresh_pig_organ_conditioning_wastewater)
Record this source-separated wastewater only when the corresponding process branch is included and the stream enters on-site management.
- Selected flow: Fresh-pig-organ-conditioning wastewater
- Flow property / unit: Volume / m3
- Amount rule: Transferred wastewater volume reconciled to the originating process records.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_and_wastewater_management_wastewater_balance_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Chilled-pig-organ-conditioning wastewater entering wastewater management (sanitation_and_wastewater_management_chilled_pig_organ_conditioning_wastewater)
Record this source-separated wastewater only when the corresponding process branch is included and the stream enters on-site management.
- Selected flow: Chilled-pig-organ-conditioning wastewater
- Flow property / unit: Volume / m3
- Amount rule: Transferred wastewater volume reconciled to the originating process records.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_and_wastewater_management_wastewater_balance_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Frozen-pig-organ-conditioning wastewater entering wastewater management (sanitation_and_wastewater_management_frozen_pig_organ_conditioning_wastewater)
Record this source-separated wastewater only when the corresponding process branch is included and the stream enters on-site management.
- Selected flow: Frozen-pig-organ-conditioning wastewater
- Flow property / unit: Volume / m3
- Amount rule: Transferred wastewater volume reconciled to the originating process records.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_and_wastewater_management_wastewater_balance_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Elementary flows
Sanitation and wastewater management groundwater abstraction (sanitation_and_wastewater_management_water_ground)
Record direct groundwater abstraction crossing the elementary boundary for sanitation and wastewater management; do not duplicate mains water.
- Selected flow: Water, ground
- Flow property / unit: Volume / m3
- Amount rule: Metered groundwater abstraction attributable to this stage.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_and_wastewater_management_water_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Sanitation and wastewater management surface-water abstraction (sanitation_and_wastewater_management_water_surface)
Record direct surface-water abstraction crossing the elementary boundary for sanitation and wastewater management; do not duplicate mains water.
- Selected flow: Water, surface
- Flow property / unit: Volume / m3
- Amount rule: Metered surface-water abstraction attributable to this stage.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_and_wastewater_management_water_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Outputs
Product flows
No atomic exchange is defined for this direction and flow type.
Waste flows
Segregated high-strength pig-organ-processing wastewater (sanitation_and_wastewater_management_segregated_high_strength_pig_organ_wastewater)
Record segregated high-strength pig-organ-processing wastewater as a separate output with the actual treatment or disposal destination; never net it against another stream.
- Selected flow: Segregated high-strength pig-organ-processing wastewater
- Flow property / unit: Volume / m3
- Amount rule: Measured volume and destination of segregated high-strength pig-organ-processing wastewater.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_and_wastewater_management_wastewater_output_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Segregated low-strength pig-organ-processing wastewater (sanitation_and_wastewater_management_segregated_low_strength_pig_organ_wastewater)
Record segregated low-strength pig-organ-processing wastewater as a separate output with the actual treatment or disposal destination; never net it against another stream.
- Selected flow: Segregated low-strength pig-organ-processing wastewater
- Flow property / unit: Volume / m3
- Amount rule: Measured volume and destination of segregated low-strength pig-organ-processing wastewater.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_and_wastewater_management_wastewater_output_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Treated pig-organ-processing effluent (sanitation_and_wastewater_management_treated_pig_organ_effluent)
Record treated pig-organ-processing effluent as a separate output with the actual treatment or disposal destination; never net it against another stream.
- Selected flow: Treated pig-organ-processing effluent
- Flow property / unit: Volume / m3
- Amount rule: Measured volume and destination of treated pig-organ-processing effluent.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_and_wastewater_management_wastewater_output_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Wastewater-treatment sludge (sanitation_and_wastewater_management_wastewater_treatment_sludge)
Record wastewater-treatment sludge as a separate output with the actual treatment or disposal destination; never net it against another stream.
- Selected flow: Wastewater-treatment sludge
- Flow property / unit: Volume / m3
- Amount rule: Measured volume and destination of wastewater-treatment sludge.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_and_wastewater_management_wastewater_output_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Pig-organ-processing screen residue (sanitation_and_wastewater_management_pig_organ_screen_residue)
Record pig-organ-processing screen residue as a separate output with the actual treatment or disposal destination; never net it against another stream.
- Selected flow: Pig-organ-processing screen residue
- Flow property / unit: Mass / kg
- Amount rule: Measured mass and destination of pig-organ-processing screen residue.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_and_wastewater_management_wastewater_output_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Waste pig fat from grease separation (sanitation_and_wastewater_management_grease_separation_pig_fat)
Record waste pig fat from grease separation as a separate output with the actual treatment or disposal destination; never net it against another stream.
- Selected flow: Waste pig fat from grease separation
- Flow property / unit: Mass / kg
- Amount rule: Measured mass and destination of waste pig fat from grease separation.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_and_wastewater_management_wastewater_output_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Elementary flows
chemical oxygen demand discharge (sanitation_and_wastewater_management_chemical_oxygen_demand_water)
Record chemical oxygen demand discharged to the receiving water compartment as its own elementary exchange after any on-site treatment.
- Selected flow: Chemical oxygen demand to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate discharged chemical oxygen demand under calc_wastewater_pollutant_load from matched effluent volume and concentration records; no default concentration is permitted.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_and_wastewater_management_effluent_sampling_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
biochemical oxygen demand discharge (sanitation_and_wastewater_management_biochemical_oxygen_demand_water)
Record biochemical oxygen demand discharged to the receiving water compartment as its own elementary exchange after any on-site treatment.
- Selected flow: Biochemical oxygen demand to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate discharged biochemical oxygen demand under calc_wastewater_pollutant_load from matched effluent volume and concentration records; no default concentration is permitted.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_and_wastewater_management_effluent_sampling_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
suspended solids discharge (sanitation_and_wastewater_management_suspended_solids_water)
Record suspended solids discharged to the receiving water compartment as its own elementary exchange after any on-site treatment.
- Selected flow: Suspended solids to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate discharged suspended solids under calc_wastewater_pollutant_load from matched effluent volume and concentration records; no default concentration is permitted.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_and_wastewater_management_effluent_sampling_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
ammonium as nitrogen discharge (sanitation_and_wastewater_management_ammonium_as_n_water)
Record ammonium as nitrogen discharged to the receiving water compartment as its own elementary exchange after any on-site treatment.
- Selected flow: Ammonium, as nitrogen, to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate discharged ammonium as nitrogen under calc_wastewater_pollutant_load from matched effluent volume and concentration records; no default concentration is permitted.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_and_wastewater_management_effluent_sampling_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
nitrate as nitrogen discharge (sanitation_and_wastewater_management_nitrate_as_n_water)
Record nitrate as nitrogen discharged to the receiving water compartment as its own elementary exchange after any on-site treatment.
- Selected flow: Nitrate, as nitrogen, to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate discharged nitrate as nitrogen under calc_wastewater_pollutant_load from matched effluent volume and concentration records; no default concentration is permitted.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_and_wastewater_management_effluent_sampling_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
nitrite as nitrogen discharge (sanitation_and_wastewater_management_nitrite_as_n_water)
Record nitrite as nitrogen discharged to the receiving water compartment as its own elementary exchange after any on-site treatment.
- Selected flow: Nitrite, as nitrogen, to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate discharged nitrite as nitrogen under calc_wastewater_pollutant_load from matched effluent volume and concentration records; no default concentration is permitted.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_and_wastewater_management_effluent_sampling_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
phosphate as phosphorus discharge (sanitation_and_wastewater_management_phosphate_as_p_water)
Record phosphate as phosphorus discharged to the receiving water compartment as its own elementary exchange after any on-site treatment.
- Selected flow: Phosphate, as phosphorus, to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate discharged phosphate as phosphorus under calc_wastewater_pollutant_load from matched effluent volume and concentration records; no default concentration is permitted.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_and_wastewater_management_effluent_sampling_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
chloride discharge (sanitation_and_wastewater_management_chloride_water)
Record chloride discharged to the receiving water compartment as its own elementary exchange after any on-site treatment.
- Selected flow: Chloride to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate discharged chloride under calc_wastewater_pollutant_load from matched effluent volume and concentration records; no default concentration is permitted.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_and_wastewater_management_effluent_sampling_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Sanitation and wastewater management direct fossil carbon dioxide (sanitation_and_wastewater_management_carbon_dioxide_fossil_air)
Record only direct fossil carbon dioxide released by on-site combustion assigned to sanitation and wastewater management; exclude upstream energy-supply emissions.
- Selected flow: Carbon dioxide, fossil, to air
- Flow property / unit: Mass / kg
- Amount rule: Calculated stage-specific direct emission under calc_combustion_air_emissions from monitored emissions or the recorded single-fuel input.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_and_wastewater_management_air_emission_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Sanitation and wastewater management direct carbon monoxide (sanitation_and_wastewater_management_carbon_monoxide_air)
Record only direct carbon monoxide released by on-site combustion assigned to sanitation and wastewater management; exclude upstream energy-supply emissions.
- Selected flow: Carbon monoxide to air
- Flow property / unit: Mass / kg
- Amount rule: Calculated stage-specific direct emission under calc_combustion_air_emissions from monitored emissions or the recorded single-fuel input.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_and_wastewater_management_air_emission_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Sanitation and wastewater management direct fossil methane (sanitation_and_wastewater_management_methane_fossil_air)
Record only direct fossil methane released by on-site combustion assigned to sanitation and wastewater management; exclude upstream energy-supply emissions.
- Selected flow: Methane, fossil, to air
- Flow property / unit: Mass / kg
- Amount rule: Calculated stage-specific direct emission under calc_combustion_air_emissions from monitored emissions or the recorded single-fuel input.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_and_wastewater_management_air_emission_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Sanitation and wastewater management direct nitrous oxide (sanitation_and_wastewater_management_nitrous_oxide_air)
Record only direct nitrous oxide released by on-site combustion assigned to sanitation and wastewater management; exclude upstream energy-supply emissions.
- Selected flow: Nitrous oxide to air
- Flow property / unit: Mass / kg
- Amount rule: Calculated stage-specific direct emission under calc_combustion_air_emissions from monitored emissions or the recorded single-fuel input.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_and_wastewater_management_air_emission_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Sanitation and wastewater management direct nitric oxide (sanitation_and_wastewater_management_nitric_oxide_air)
Record only direct nitric oxide released by on-site combustion assigned to sanitation and wastewater management; exclude upstream energy-supply emissions.
- Selected flow: Nitric oxide to air
- Flow property / unit: Mass / kg
- Amount rule: Calculated stage-specific direct emission under calc_combustion_air_emissions from monitored emissions or the recorded single-fuel input.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_and_wastewater_management_air_emission_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Sanitation and wastewater management direct nitrogen dioxide (sanitation_and_wastewater_management_nitrogen_dioxide_air)
Record only direct nitrogen dioxide released by on-site combustion assigned to sanitation and wastewater management; exclude upstream energy-supply emissions.
- Selected flow: Nitrogen dioxide to air
- Flow property / unit: Mass / kg
- Amount rule: Calculated stage-specific direct emission under calc_combustion_air_emissions from monitored emissions or the recorded single-fuel input.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_and_wastewater_management_air_emission_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Sanitation and wastewater management direct sulfur dioxide (sanitation_and_wastewater_management_sulfur_dioxide_air)
Record only direct sulfur dioxide released by on-site combustion assigned to sanitation and wastewater management; exclude upstream energy-supply emissions.
- Selected flow: Sulfur dioxide to air
- Flow property / unit: Mass / kg
- Amount rule: Calculated stage-specific direct emission under calc_combustion_air_emissions from monitored emissions or the recorded single-fuel input.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_and_wastewater_management_air_emission_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Sanitation and wastewater management direct particulate matter below 2.5 micrometres (sanitation_and_wastewater_management_pm_below_2_5_air)
Record only direct particulate matter below 2.5 micrometres released by on-site combustion assigned to sanitation and wastewater management; exclude upstream energy-supply emissions.
- Selected flow: Particulate matter below 2.5 micrometres to air
- Flow property / unit: Mass / kg
- Amount rule: Calculated stage-specific direct emission under calc_combustion_air_emissions from monitored emissions or the recorded single-fuel input.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_and_wastewater_management_air_emission_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
Sanitation and wastewater management direct particulate matter from 2.5 to 10 micrometres (sanitation_and_wastewater_management_pm_2_5_to_10_air)
Record only direct particulate matter from 2.5 to 10 micrometres released by on-site combustion assigned to sanitation and wastewater management; exclude upstream energy-supply emissions.
- Selected flow: Particulate matter from 2.5 to 10 micrometres to air
- Flow property / unit: Mass / kg
- Amount rule: Calculated stage-specific direct emission under calc_combustion_air_emissions from monitored emissions or the recorded single-fuel input.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_and_wastewater_management_air_emission_records - Sources:
eu-jrc-sa-bref;eu-pef-2021-2279
7. Allocation and Co-product Handling
| rule_id | Applies to | Rule | source_ids |
|---|---|---|---|
allocation_avoid | foreground burden allocation | Avoid allocation by subdividing independently measurable organ preparation, state conditioning, packaging, sanitation and treatment processes before applying any allocation key. | eu-pef-2021-2279 |
allocation_direct_assignment | direct process assignment | Assign metered electricity, thermal carriers, fuels, water, chemicals, packaging, wastes and emissions directly to the process and organ-state lot that caused them whenever records permit. | eu-pef-2021-2279 |
allocation_slaughter_coproducts | integrated slaughter | Treat the selected edible organ, pig carcass and each beneficially used named output as separate slaughter co-products; keep condemned or discarded outputs as wastes. | eu-jrc-sa-bref; eu-pef-2021-2279 |
allocation_slaughter_relation | residual slaughter burden | For residual inseparable slaughter burdens, use a documented physical causal relationship where it can be demonstrated; if it cannot, use reporting-period economic values for the exact co-products and disclose the sensitivity. | eu-pef-2021-2279 |
allocation_no_defaults | allocation factors | Calculate allocation shares from foreground co-product quantities and, where used, contemporaneous values; do not insert a PCR default share or price. | eu-pef-2021-2279 |
allocation_purchased_organ | purchased-organ route | Use the supplier slaughter dataset's disclosed organ allocation once and do not reallocate those upstream burdens again in the receiving preparation process. | eu-pef-2021-2279 |
allocation_waste_treatment | waste treatment | Assign treatment burdens to the process generating each named waste or wastewater stream unless an explicitly documented facility-wide causal key is required; do not credit a waste as a co-product without a documented beneficial product destination. | eu-jrc-sa-bref; eu-pef-2021-2279 |
allocation_mass_balance | allocation verification | Reconcile allocated process totals to unallocated facility totals and document any unassigned difference, shared-service key and organ-state denominator. | eu-pef-2021-2279 |
8. Foreground Data Collection, Calculation, and Quality Rules
Data Collection Protocols
| protocol_id | process_id | flow_role | record_type | raw_fields | collection_method | unit | frequency | temporal_coverage | site_scope | aggregation_rule | quality_evidence |
|---|---|---|---|---|---|---|---|---|---|---|---|
cp_pig_receipt_and_ante_mortem_animal_receipt_records | pig_receipt_and_ante_mortem | live-pig receipt and ante-mortem disposition | weighbridge and inspection record | lot_id; supplier_id; receipt_time; animal_count; gross_mass; tare_mass; acceptance_status; disposition | Reconcile calibrated weighbridge tickets with veterinary acceptance records by lot. | kg and count | each received lot | all lots in the reporting period | reporting facility | Sum accepted and rejected masses separately; retain lot identity. | weighbridge calibration; veterinary record; reconciliation sign-off |
cp_pig_receipt_and_ante_mortem_receipt_waste_records | pig_receipt_and_ante_mortem | receipt waste mass and destination | waste weighing and dispatch record | lot_id; waste_identity; measured_mass; container_tare; destination; dispatch_date | Weigh each named waste stream and reconcile dispatch records. | kg | each lot or dispatch | all included receipt operations | reporting facility | Sum by exact waste identity and destination before allocation. | scale calibration; waste transfer record; mass-balance review |
cp_pig_receipt_and_ante_mortem_water_records | pig_receipt_and_ante_mortem | single-source water consumption or abstraction | water meter and allocation record | meter_id; water_source_identity; opening_reading; closing_reading; timestamp; stage_allocation_key | Read calibrated source-specific meters and reconcile shared meters to operating records. | m3 | continuous or each production shift | all operating and cleaning periods assigned to the stage | reporting facility and stated source point | Subtract opening from closing reading and allocate only with a documented causal key. | meter calibration; meter map; reading log; reconciliation |
cp_pig_receipt_and_ante_mortem_electricity_records | pig_receipt_and_ante_mortem | grid-electricity consumption | electricity meter and invoice record | meter_id; supplier; tariff_or_grid_identity; opening_reading; closing_reading; timestamp; stage_allocation_key | Reconcile stage submeter readings with facility invoices. | kWh | continuous or each production shift | all operating periods assigned to the stage | reporting facility | Calculate net consumption by meter and assign shared use with a disclosed causal key. | meter calibration; invoice reconciliation; submeter coverage |
cp_pig_receipt_and_ante_mortem_thermal_records | pig_receipt_and_ante_mortem | single purchased thermal carrier consumption | thermal meter and supplier record | carrier_identity; meter_id; opening_reading; closing_reading; temperature; pressure; enthalpy_basis; timestamp; allocation_key | Meter steam and hot water separately and convert only with recorded thermodynamic conditions. | MJ with original meter unit retained | continuous or each production shift | all operating periods assigned to the stage | reporting facility | Sum each carrier separately; never combine steam and hot water. | meter calibration; supplier record; conversion worksheet |
cp_pig_receipt_and_ante_mortem_fuel_records | pig_receipt_and_ante_mortem | single fuel consumption | fuel meter, invoice and stock-balance record | fuel_identity; opening_stock; receipts; closing_stock; meter_reading; lower_heating_value_if_used; timestamp; stage_allocation_key | Reconcile each fuel identity independently from tank, meter and invoice records. | kg or MJ as recorded | each delivery and monthly reconciliation | all fuel assigned to the stage | reporting facility | Opening stock plus receipts minus closing stock, separated by fuel identity. | tank calibration; invoices; stock reconciliation; fuel specification |
cp_pig_receipt_and_ante_mortem_air_emission_records | pig_receipt_and_ante_mortem | single direct combustion emission | stack measurement or fuel-based calculation record | pollutant_identity; stack_id; concentration; exhaust_flow; monitoring_time; fuel_identity; fuel_quantity; approved_factor_if_used; allocation_key | Use matched stack measurements where available; otherwise calculate separately for each pollutant and fuel from recorded activity and a disclosed factor. | kg | monitoring event and reporting-period calculation | all on-site combustion assigned to the stage | reporting facility direct releases | Apply calc_combustion_air_emissions by pollutant and stage; do not include upstream emissions. | monitoring report; fuel record; factor provenance; calculation review |
cp_slaughter_and_organ_recovery_slaughter_mass_balance | slaughter_and_organ_recovery | slaughter input, recovered organ and co-product mass balance | lot-specific slaughter yield record | lot_id; accepted_live_mass; exact_output_identity; gross_output_mass; tare_mass; edible_status; destination; timestamp | Weigh each organ and each co-product separately and reconcile to accepted live-pig input. | kg | each slaughter lot | all integrated-slaughter lots in the reporting period | reporting slaughter line | Apply calc_slaughter_mass_balance by exact output identity; retain unaccounted-mass investigation. | scale calibration; veterinary disposition; signed mass-balance reconciliation |
cp_slaughter_and_organ_recovery_slaughter_waste_records | slaughter_and_organ_recovery | single slaughter waste mass and destination | waste weighing and dispatch record | lot_id; exact_waste_identity; measured_mass; destination; treatment_route; timestamp | Weigh each named slaughter waste separately and reconcile with dispatch or treatment records. | kg | each lot or dispatch | all integrated-slaughter lots | reporting slaughter line | Sum by exact waste identity and destination; prohibit product-waste double counting. | scale calibration; disposition record; mass-balance reconciliation |
cp_slaughter_and_organ_recovery_wastewater_records | slaughter_and_organ_recovery | process-specific wastewater generation | wastewater meter or batch wash record | source_process; stream_identity; meter_reading; batch_volume; start_time; end_time; organ_identity; state_identity | Meter the named process wastewater or calculate volume from verified batch wash records. | m3 | each batch or continuous meter interval | all included production lots | reporting facility | Apply the recorded source-process link and avoid double counting sanitation water. | meter calibration; wash-cycle log; source-stream reconciliation |
cp_slaughter_and_organ_recovery_water_records | slaughter_and_organ_recovery | single-source water consumption or abstraction | water meter and allocation record | meter_id; water_source_identity; opening_reading; closing_reading; timestamp; stage_allocation_key | Read calibrated source-specific meters and reconcile shared meters to operating records. | m3 | continuous or each production shift | all operating and cleaning periods assigned to the stage | reporting facility and stated source point | Subtract opening from closing reading and allocate only with a documented causal key. | meter calibration; meter map; reading log; reconciliation |
cp_slaughter_and_organ_recovery_electricity_records | slaughter_and_organ_recovery | grid-electricity consumption | electricity meter and invoice record | meter_id; supplier; tariff_or_grid_identity; opening_reading; closing_reading; timestamp; stage_allocation_key | Reconcile stage submeter readings with facility invoices. | kWh | continuous or each production shift | all operating periods assigned to the stage | reporting facility | Calculate net consumption by meter and assign shared use with a disclosed causal key. | meter calibration; invoice reconciliation; submeter coverage |
cp_slaughter_and_organ_recovery_thermal_records | slaughter_and_organ_recovery | single purchased thermal carrier consumption | thermal meter and supplier record | carrier_identity; meter_id; opening_reading; closing_reading; temperature; pressure; enthalpy_basis; timestamp; allocation_key | Meter steam and hot water separately and convert only with recorded thermodynamic conditions. | MJ with original meter unit retained | continuous or each production shift | all operating periods assigned to the stage | reporting facility | Sum each carrier separately; never combine steam and hot water. | meter calibration; supplier record; conversion worksheet |
cp_slaughter_and_organ_recovery_fuel_records | slaughter_and_organ_recovery | single fuel consumption | fuel meter, invoice and stock-balance record | fuel_identity; opening_stock; receipts; closing_stock; meter_reading; lower_heating_value_if_used; timestamp; stage_allocation_key | Reconcile each fuel identity independently from tank, meter and invoice records. | kg or MJ as recorded | each delivery and monthly reconciliation | all fuel assigned to the stage | reporting facility | Opening stock plus receipts minus closing stock, separated by fuel identity. | tank calibration; invoices; stock reconciliation; fuel specification |
cp_slaughter_and_organ_recovery_air_emission_records | slaughter_and_organ_recovery | single direct combustion emission | stack measurement or fuel-based calculation record | pollutant_identity; stack_id; concentration; exhaust_flow; monitoring_time; fuel_identity; fuel_quantity; approved_factor_if_used; allocation_key | Use matched stack measurements where available; otherwise calculate separately for each pollutant and fuel from recorded activity and a disclosed factor. | kg | monitoring event and reporting-period calculation | all on-site combustion assigned to the stage | reporting facility direct releases | Apply calc_combustion_air_emissions by pollutant and stage; do not include upstream emissions. | monitoring report; fuel record; factor provenance; calculation review |
cp_edible_organ_preparation_organ_mass_balance | edible_organ_preparation | received, prepared and trimmed organ mass | organ-lot mass-balance record | lot_id; exact_organ_identity; received_mass; prepared_mass; trimming_waste_mass; hold_or_drain_change; disposition | Weigh the one declared organ at receipt, after preparation and at each reject point. | kg | each organ lot | all prepared lots | reporting preparation line | Apply calc_organ_preparation_mass_balance for one organ identity at a time. | scale calibration; organ identity traceability; signed mass balance |
cp_edible_organ_preparation_preparation_waste_records | edible_organ_preparation | organ-specific preparation reject mass | reject weighing and destination record | lot_id; exact_organ_identity; reject_identity; measured_mass; destination; timestamp | Weigh trimmings separately for the declared organ and record final destination. | kg | each organ lot | all prepared lots | reporting preparation line | Sum by exact organ and waste identity; reconcile to organ mass balance. | scale calibration; disposition record; mass-balance review |
cp_edible_organ_preparation_wastewater_records | edible_organ_preparation | process-specific wastewater generation | wastewater meter or batch wash record | source_process; stream_identity; meter_reading; batch_volume; start_time; end_time; organ_identity; state_identity | Meter the named process wastewater or calculate volume from verified batch wash records. | m3 | each batch or continuous meter interval | all included production lots | reporting facility | Apply the recorded source-process link and avoid double counting sanitation water. | meter calibration; wash-cycle log; source-stream reconciliation |
cp_edible_organ_preparation_water_records | edible_organ_preparation | single-source water consumption or abstraction | water meter and allocation record | meter_id; water_source_identity; opening_reading; closing_reading; timestamp; stage_allocation_key | Read calibrated source-specific meters and reconcile shared meters to operating records. | m3 | continuous or each production shift | all operating and cleaning periods assigned to the stage | reporting facility and stated source point | Subtract opening from closing reading and allocate only with a documented causal key. | meter calibration; meter map; reading log; reconciliation |
cp_edible_organ_preparation_electricity_records | edible_organ_preparation | grid-electricity consumption | electricity meter and invoice record | meter_id; supplier; tariff_or_grid_identity; opening_reading; closing_reading; timestamp; stage_allocation_key | Reconcile stage submeter readings with facility invoices. | kWh | continuous or each production shift | all operating periods assigned to the stage | reporting facility | Calculate net consumption by meter and assign shared use with a disclosed causal key. | meter calibration; invoice reconciliation; submeter coverage |
cp_edible_organ_preparation_thermal_records | edible_organ_preparation | single purchased thermal carrier consumption | thermal meter and supplier record | carrier_identity; meter_id; opening_reading; closing_reading; temperature; pressure; enthalpy_basis; timestamp; allocation_key | Meter steam and hot water separately and convert only with recorded thermodynamic conditions. | MJ with original meter unit retained | continuous or each production shift | all operating periods assigned to the stage | reporting facility | Sum each carrier separately; never combine steam and hot water. | meter calibration; supplier record; conversion worksheet |
cp_edible_organ_preparation_fuel_records | edible_organ_preparation | single fuel consumption | fuel meter, invoice and stock-balance record | fuel_identity; opening_stock; receipts; closing_stock; meter_reading; lower_heating_value_if_used; timestamp; stage_allocation_key | Reconcile each fuel identity independently from tank, meter and invoice records. | kg or MJ as recorded | each delivery and monthly reconciliation | all fuel assigned to the stage | reporting facility | Opening stock plus receipts minus closing stock, separated by fuel identity. | tank calibration; invoices; stock reconciliation; fuel specification |
cp_edible_organ_preparation_air_emission_records | edible_organ_preparation | single direct combustion emission | stack measurement or fuel-based calculation record | pollutant_identity; stack_id; concentration; exhaust_flow; monitoring_time; fuel_identity; fuel_quantity; approved_factor_if_used; allocation_key | Use matched stack measurements where available; otherwise calculate separately for each pollutant and fuel from recorded activity and a disclosed factor. | kg | monitoring event and reporting-period calculation | all on-site combustion assigned to the stage | reporting facility direct releases | Apply calc_combustion_air_emissions by pollutant and stage; do not include upstream emissions. | monitoring report; fuel record; factor provenance; calculation review |
cp_fresh_state_conditioning_state_mass_balance | fresh_state_conditioning | single-organ state-conditioning mass balance | state-conditioning batch record | lot_id; exact_organ_identity; declared_state; input_mass; conforming_output_mass; reject_mass; start_time; end_time; temperature_record | Weigh one organ entering and leaving exactly one declared state branch and retain the temperature-time record. | kg and degrees Celsius with time | each state-conditioning lot | all lots in the selected state branch | reporting state-conditioning line | Apply calc_state_conditioning_mass_balance only within the selected organ-state combination. | scale calibration; calibrated temperature logger; branch-selection review |
cp_fresh_state_conditioning_state_waste_records | fresh_state_conditioning | organ-state-specific reject mass | reject weighing and destination record | lot_id; exact_organ_identity; declared_state; measured_reject_mass; rejection_reason; destination | Weigh rejected product separately for the exact organ-state combination. | kg | each conditioning lot | all lots in the selected state branch | reporting state-conditioning line | Sum by exact organ, state and destination; reconcile to the state mass balance. | scale calibration; rejection record; destination evidence |
cp_fresh_state_conditioning_wastewater_records | fresh_state_conditioning | process-specific wastewater generation | wastewater meter or batch wash record | source_process; stream_identity; meter_reading; batch_volume; start_time; end_time; organ_identity; state_identity | Meter the named process wastewater or calculate volume from verified batch wash records. | m3 | each batch or continuous meter interval | all included production lots | reporting facility | Apply the recorded source-process link and avoid double counting sanitation water. | meter calibration; wash-cycle log; source-stream reconciliation |
cp_fresh_state_conditioning_water_records | fresh_state_conditioning | single-source water consumption or abstraction | water meter and allocation record | meter_id; water_source_identity; opening_reading; closing_reading; timestamp; stage_allocation_key | Read calibrated source-specific meters and reconcile shared meters to operating records. | m3 | continuous or each production shift | all operating and cleaning periods assigned to the stage | reporting facility and stated source point | Subtract opening from closing reading and allocate only with a documented causal key. | meter calibration; meter map; reading log; reconciliation |
cp_fresh_state_conditioning_electricity_records | fresh_state_conditioning | grid-electricity consumption | electricity meter and invoice record | meter_id; supplier; tariff_or_grid_identity; opening_reading; closing_reading; timestamp; stage_allocation_key | Reconcile stage submeter readings with facility invoices. | kWh | continuous or each production shift | all operating periods assigned to the stage | reporting facility | Calculate net consumption by meter and assign shared use with a disclosed causal key. | meter calibration; invoice reconciliation; submeter coverage |
cp_fresh_state_conditioning_thermal_records | fresh_state_conditioning | single purchased thermal carrier consumption | thermal meter and supplier record | carrier_identity; meter_id; opening_reading; closing_reading; temperature; pressure; enthalpy_basis; timestamp; allocation_key | Meter steam and hot water separately and convert only with recorded thermodynamic conditions. | MJ with original meter unit retained | continuous or each production shift | all operating periods assigned to the stage | reporting facility | Sum each carrier separately; never combine steam and hot water. | meter calibration; supplier record; conversion worksheet |
cp_fresh_state_conditioning_fuel_records | fresh_state_conditioning | single fuel consumption | fuel meter, invoice and stock-balance record | fuel_identity; opening_stock; receipts; closing_stock; meter_reading; lower_heating_value_if_used; timestamp; stage_allocation_key | Reconcile each fuel identity independently from tank, meter and invoice records. | kg or MJ as recorded | each delivery and monthly reconciliation | all fuel assigned to the stage | reporting facility | Opening stock plus receipts minus closing stock, separated by fuel identity. | tank calibration; invoices; stock reconciliation; fuel specification |
cp_fresh_state_conditioning_air_emission_records | fresh_state_conditioning | single direct combustion emission | stack measurement or fuel-based calculation record | pollutant_identity; stack_id; concentration; exhaust_flow; monitoring_time; fuel_identity; fuel_quantity; approved_factor_if_used; allocation_key | Use matched stack measurements where available; otherwise calculate separately for each pollutant and fuel from recorded activity and a disclosed factor. | kg | monitoring event and reporting-period calculation | all on-site combustion assigned to the stage | reporting facility direct releases | Apply calc_combustion_air_emissions by pollutant and stage; do not include upstream emissions. | monitoring report; fuel record; factor provenance; calculation review |
cp_chilled_state_conditioning_state_mass_balance | chilled_state_conditioning | single-organ state-conditioning mass balance | state-conditioning batch record | lot_id; exact_organ_identity; declared_state; input_mass; conforming_output_mass; reject_mass; start_time; end_time; temperature_record | Weigh one organ entering and leaving exactly one declared state branch and retain the temperature-time record. | kg and degrees Celsius with time | each state-conditioning lot | all lots in the selected state branch | reporting state-conditioning line | Apply calc_state_conditioning_mass_balance only within the selected organ-state combination. | scale calibration; calibrated temperature logger; branch-selection review |
cp_chilled_state_conditioning_state_waste_records | chilled_state_conditioning | organ-state-specific reject mass | reject weighing and destination record | lot_id; exact_organ_identity; declared_state; measured_reject_mass; rejection_reason; destination | Weigh rejected product separately for the exact organ-state combination. | kg | each conditioning lot | all lots in the selected state branch | reporting state-conditioning line | Sum by exact organ, state and destination; reconcile to the state mass balance. | scale calibration; rejection record; destination evidence |
cp_chilled_state_conditioning_wastewater_records | chilled_state_conditioning | process-specific wastewater generation | wastewater meter or batch wash record | source_process; stream_identity; meter_reading; batch_volume; start_time; end_time; organ_identity; state_identity | Meter the named process wastewater or calculate volume from verified batch wash records. | m3 | each batch or continuous meter interval | all included production lots | reporting facility | Apply the recorded source-process link and avoid double counting sanitation water. | meter calibration; wash-cycle log; source-stream reconciliation |
cp_chilled_state_conditioning_water_records | chilled_state_conditioning | single-source water consumption or abstraction | water meter and allocation record | meter_id; water_source_identity; opening_reading; closing_reading; timestamp; stage_allocation_key | Read calibrated source-specific meters and reconcile shared meters to operating records. | m3 | continuous or each production shift | all operating and cleaning periods assigned to the stage | reporting facility and stated source point | Subtract opening from closing reading and allocate only with a documented causal key. | meter calibration; meter map; reading log; reconciliation |
cp_chilled_state_conditioning_electricity_records | chilled_state_conditioning | grid-electricity consumption | electricity meter and invoice record | meter_id; supplier; tariff_or_grid_identity; opening_reading; closing_reading; timestamp; stage_allocation_key | Reconcile stage submeter readings with facility invoices. | kWh | continuous or each production shift | all operating periods assigned to the stage | reporting facility | Calculate net consumption by meter and assign shared use with a disclosed causal key. | meter calibration; invoice reconciliation; submeter coverage |
cp_chilled_state_conditioning_thermal_records | chilled_state_conditioning | single purchased thermal carrier consumption | thermal meter and supplier record | carrier_identity; meter_id; opening_reading; closing_reading; temperature; pressure; enthalpy_basis; timestamp; allocation_key | Meter steam and hot water separately and convert only with recorded thermodynamic conditions. | MJ with original meter unit retained | continuous or each production shift | all operating periods assigned to the stage | reporting facility | Sum each carrier separately; never combine steam and hot water. | meter calibration; supplier record; conversion worksheet |
cp_chilled_state_conditioning_fuel_records | chilled_state_conditioning | single fuel consumption | fuel meter, invoice and stock-balance record | fuel_identity; opening_stock; receipts; closing_stock; meter_reading; lower_heating_value_if_used; timestamp; stage_allocation_key | Reconcile each fuel identity independently from tank, meter and invoice records. | kg or MJ as recorded | each delivery and monthly reconciliation | all fuel assigned to the stage | reporting facility | Opening stock plus receipts minus closing stock, separated by fuel identity. | tank calibration; invoices; stock reconciliation; fuel specification |
cp_chilled_state_conditioning_air_emission_records | chilled_state_conditioning | single direct combustion emission | stack measurement or fuel-based calculation record | pollutant_identity; stack_id; concentration; exhaust_flow; monitoring_time; fuel_identity; fuel_quantity; approved_factor_if_used; allocation_key | Use matched stack measurements where available; otherwise calculate separately for each pollutant and fuel from recorded activity and a disclosed factor. | kg | monitoring event and reporting-period calculation | all on-site combustion assigned to the stage | reporting facility direct releases | Apply calc_combustion_air_emissions by pollutant and stage; do not include upstream emissions. | monitoring report; fuel record; factor provenance; calculation review |
cp_chilled_state_conditioning_refrigerant_records | chilled_state_conditioning | single refrigerant charge, make-up, recovery and release balance | refrigeration service and stock record | equipment_id; exact_refrigerant_identity; opening_charge; make_up_mass; recovered_mass; closing_charge; service_date; supplier_composition | Reconcile each installed refrigerant separately from service logs and stock records. | kg | each service event and annual reconciliation | all refrigeration equipment assigned to the stage | reporting facility | Apply calc_refrigerant_mass_balance per exact substance; use supplier composition for R-404A constituents. | service certificate; calibrated cylinder scale; stock reconciliation; supplier specification |
cp_frozen_state_conditioning_state_mass_balance | frozen_state_conditioning | single-organ state-conditioning mass balance | state-conditioning batch record | lot_id; exact_organ_identity; declared_state; input_mass; conforming_output_mass; reject_mass; start_time; end_time; temperature_record | Weigh one organ entering and leaving exactly one declared state branch and retain the temperature-time record. | kg and degrees Celsius with time | each state-conditioning lot | all lots in the selected state branch | reporting state-conditioning line | Apply calc_state_conditioning_mass_balance only within the selected organ-state combination. | scale calibration; calibrated temperature logger; branch-selection review |
cp_frozen_state_conditioning_state_waste_records | frozen_state_conditioning | organ-state-specific reject mass | reject weighing and destination record | lot_id; exact_organ_identity; declared_state; measured_reject_mass; rejection_reason; destination | Weigh rejected product separately for the exact organ-state combination. | kg | each conditioning lot | all lots in the selected state branch | reporting state-conditioning line | Sum by exact organ, state and destination; reconcile to the state mass balance. | scale calibration; rejection record; destination evidence |
cp_frozen_state_conditioning_wastewater_records | frozen_state_conditioning | process-specific wastewater generation | wastewater meter or batch wash record | source_process; stream_identity; meter_reading; batch_volume; start_time; end_time; organ_identity; state_identity | Meter the named process wastewater or calculate volume from verified batch wash records. | m3 | each batch or continuous meter interval | all included production lots | reporting facility | Apply the recorded source-process link and avoid double counting sanitation water. | meter calibration; wash-cycle log; source-stream reconciliation |
cp_frozen_state_conditioning_water_records | frozen_state_conditioning | single-source water consumption or abstraction | water meter and allocation record | meter_id; water_source_identity; opening_reading; closing_reading; timestamp; stage_allocation_key | Read calibrated source-specific meters and reconcile shared meters to operating records. | m3 | continuous or each production shift | all operating and cleaning periods assigned to the stage | reporting facility and stated source point | Subtract opening from closing reading and allocate only with a documented causal key. | meter calibration; meter map; reading log; reconciliation |
cp_frozen_state_conditioning_electricity_records | frozen_state_conditioning | grid-electricity consumption | electricity meter and invoice record | meter_id; supplier; tariff_or_grid_identity; opening_reading; closing_reading; timestamp; stage_allocation_key | Reconcile stage submeter readings with facility invoices. | kWh | continuous or each production shift | all operating periods assigned to the stage | reporting facility | Calculate net consumption by meter and assign shared use with a disclosed causal key. | meter calibration; invoice reconciliation; submeter coverage |
cp_frozen_state_conditioning_thermal_records | frozen_state_conditioning | single purchased thermal carrier consumption | thermal meter and supplier record | carrier_identity; meter_id; opening_reading; closing_reading; temperature; pressure; enthalpy_basis; timestamp; allocation_key | Meter steam and hot water separately and convert only with recorded thermodynamic conditions. | MJ with original meter unit retained | continuous or each production shift | all operating periods assigned to the stage | reporting facility | Sum each carrier separately; never combine steam and hot water. | meter calibration; supplier record; conversion worksheet |
cp_frozen_state_conditioning_fuel_records | frozen_state_conditioning | single fuel consumption | fuel meter, invoice and stock-balance record | fuel_identity; opening_stock; receipts; closing_stock; meter_reading; lower_heating_value_if_used; timestamp; stage_allocation_key | Reconcile each fuel identity independently from tank, meter and invoice records. | kg or MJ as recorded | each delivery and monthly reconciliation | all fuel assigned to the stage | reporting facility | Opening stock plus receipts minus closing stock, separated by fuel identity. | tank calibration; invoices; stock reconciliation; fuel specification |
cp_frozen_state_conditioning_air_emission_records | frozen_state_conditioning | single direct combustion emission | stack measurement or fuel-based calculation record | pollutant_identity; stack_id; concentration; exhaust_flow; monitoring_time; fuel_identity; fuel_quantity; approved_factor_if_used; allocation_key | Use matched stack measurements where available; otherwise calculate separately for each pollutant and fuel from recorded activity and a disclosed factor. | kg | monitoring event and reporting-period calculation | all on-site combustion assigned to the stage | reporting facility direct releases | Apply calc_combustion_air_emissions by pollutant and stage; do not include upstream emissions. | monitoring report; fuel record; factor provenance; calculation review |
cp_frozen_state_conditioning_refrigerant_records | frozen_state_conditioning | single refrigerant charge, make-up, recovery and release balance | refrigeration service and stock record | equipment_id; exact_refrigerant_identity; opening_charge; make_up_mass; recovered_mass; closing_charge; service_date; supplier_composition | Reconcile each installed refrigerant separately from service logs and stock records. | kg | each service event and annual reconciliation | all refrigeration equipment assigned to the stage | reporting facility | Apply calc_refrigerant_mass_balance per exact substance; use supplier composition for R-404A constituents. | service certificate; calibrated cylinder scale; stock reconciliation; supplier specification |
cp_packaging_storage_and_release_release_mass_records | packaging_storage_and_release | one organ-state product entering packaging and release | lot release and weighing record | lot_id; exact_organ_identity; declared_state; input_net_mass; reject_mass; released_net_mass; packaging_mass; release_time | Weigh the exact organ-state product and packaging separately at release. | kg | each released lot | all reference-product lots | reporting packaging and release line | Apply calc_reference_product_normalization to net product mass only. | scale calibration; lot release certificate; product-packaging tare record |
cp_packaging_storage_and_release_release_waste_records | packaging_storage_and_release | organ-state-specific release reject mass | release reject and destination record | lot_id; exact_organ_identity; declared_state; reject_mass; rejection_reason; destination | Weigh release rejects separately for the exact organ-state combination. | kg | each released lot | all reference-product lots | reporting packaging and release line | Sum by exact organ, state and destination; reconcile with released mass. | scale calibration; release record; destination evidence |
cp_packaging_storage_and_release_packaging_bom_records | packaging_storage_and_release | single packaging component input | product-specific packaging bill of materials and issue record | lot_id; packaging_component_identity; supplier; item_count; unit_mass; total_mass; recycled_content_if_claimed | Reconcile issued packaging with a product-specific bill of materials and measured or supplier-declared unit mass. | kg and item count | each packaging specification and released lot | all packaging used for the reference product | reporting packaging line | Calculate mass separately for each named component; exclude packaging from reference-product net mass. | approved BOM; supplier specification; scale or item-count reconciliation |
cp_packaging_storage_and_release_packaging_waste_records | packaging_storage_and_release | single packaging-component waste mass | packaging reject and waste dispatch record | lot_id; exact_component_identity; measured_waste_mass; destination; timestamp | Weigh discarded packaging separately by exact component identity. | kg | each shift or dispatch | all packaging operations | reporting packaging line | Sum by exact component and destination; reconcile with packaging issued. | scale calibration; dispatch record; packaging mass balance |
cp_packaging_storage_and_release_reference_release_records | packaging_storage_and_release | reference-product net release and normalization | final release and normalization record | lot_id; exact_organ_identity; declared_state; conforming_net_mass; packaging_mass; reference_normalization_factor; release_specification | Verify one organ and one state, exclude packaging mass, then normalize the conforming net mass to 1 kg. | kg | each released lot and reporting-period aggregation | all reference-product lots | reporting packaging and release line | Apply calc_reference_product_normalization without pooling organ or state identities. | release certificate; calibrated scale; branch-selection check; normalization worksheet |
cp_packaging_storage_and_release_water_records | packaging_storage_and_release | single-source water consumption or abstraction | water meter and allocation record | meter_id; water_source_identity; opening_reading; closing_reading; timestamp; stage_allocation_key | Read calibrated source-specific meters and reconcile shared meters to operating records. | m3 | continuous or each production shift | all operating and cleaning periods assigned to the stage | reporting facility and stated source point | Subtract opening from closing reading and allocate only with a documented causal key. | meter calibration; meter map; reading log; reconciliation |
cp_packaging_storage_and_release_electricity_records | packaging_storage_and_release | grid-electricity consumption | electricity meter and invoice record | meter_id; supplier; tariff_or_grid_identity; opening_reading; closing_reading; timestamp; stage_allocation_key | Reconcile stage submeter readings with facility invoices. | kWh | continuous or each production shift | all operating periods assigned to the stage | reporting facility | Calculate net consumption by meter and assign shared use with a disclosed causal key. | meter calibration; invoice reconciliation; submeter coverage |
cp_packaging_storage_and_release_thermal_records | packaging_storage_and_release | single purchased thermal carrier consumption | thermal meter and supplier record | carrier_identity; meter_id; opening_reading; closing_reading; temperature; pressure; enthalpy_basis; timestamp; allocation_key | Meter steam and hot water separately and convert only with recorded thermodynamic conditions. | MJ with original meter unit retained | continuous or each production shift | all operating periods assigned to the stage | reporting facility | Sum each carrier separately; never combine steam and hot water. | meter calibration; supplier record; conversion worksheet |
cp_packaging_storage_and_release_fuel_records | packaging_storage_and_release | single fuel consumption | fuel meter, invoice and stock-balance record | fuel_identity; opening_stock; receipts; closing_stock; meter_reading; lower_heating_value_if_used; timestamp; stage_allocation_key | Reconcile each fuel identity independently from tank, meter and invoice records. | kg or MJ as recorded | each delivery and monthly reconciliation | all fuel assigned to the stage | reporting facility | Opening stock plus receipts minus closing stock, separated by fuel identity. | tank calibration; invoices; stock reconciliation; fuel specification |
cp_packaging_storage_and_release_air_emission_records | packaging_storage_and_release | single direct combustion emission | stack measurement or fuel-based calculation record | pollutant_identity; stack_id; concentration; exhaust_flow; monitoring_time; fuel_identity; fuel_quantity; approved_factor_if_used; allocation_key | Use matched stack measurements where available; otherwise calculate separately for each pollutant and fuel from recorded activity and a disclosed factor. | kg | monitoring event and reporting-period calculation | all on-site combustion assigned to the stage | reporting facility direct releases | Apply calc_combustion_air_emissions by pollutant and stage; do not include upstream emissions. | monitoring report; fuel record; factor provenance; calculation review |
cp_packaging_storage_and_release_refrigerant_records | packaging_storage_and_release | single refrigerant charge, make-up, recovery and release balance | refrigeration service and stock record | equipment_id; exact_refrigerant_identity; opening_charge; make_up_mass; recovered_mass; closing_charge; service_date; supplier_composition | Reconcile each installed refrigerant separately from service logs and stock records. | kg | each service event and annual reconciliation | all refrigeration equipment assigned to the stage | reporting facility | Apply calc_refrigerant_mass_balance per exact substance; use supplier composition for R-404A constituents. | service certificate; calibrated cylinder scale; stock reconciliation; supplier specification |
cp_sanitation_and_wastewater_management_wastewater_balance_records | sanitation_and_wastewater_management | source-separated wastewater transfer balance | source-stream meter and transfer record | source_process; exact_stream_identity; source_volume; transferred_volume; bypass_volume; destination; timestamp | Reconcile each named source stream between generation and on-site management. | m3 | each batch or continuous interval | all included wastewater streams | reporting facility | Balance each source stream separately and investigate discrepancies. | meter calibration; flow diagram; transfer reconciliation |
cp_sanitation_and_wastewater_management_chemical_dosing_records | sanitation_and_wastewater_management | single cleaning, disinfection or treatment chemical dose | chemical issue and dosing record | exact_chemical_identity; formulation_concentration; batch_or_meter_id; issued_mass; returned_mass; dose_time; target_operation | Reconcile each formulation identity separately from store issue, return and dosing records. | kg formulated product | each dose and monthly stock reconciliation | all cleaning, disinfection and on-site treatment operations | reporting facility | Issued minus returned mass by exact formulation; retain active concentration as metadata. | supplier SDS or specification; dosing calibration; stock reconciliation |
cp_sanitation_and_wastewater_management_wastewater_output_records | sanitation_and_wastewater_management | single wastewater-treatment output mass or volume | treatment output and destination record | exact_output_identity; measured_mass_or_volume; sampling_or_dispatch_time; destination; treatment_status | Measure each output independently at the treatment or dispatch point. | kg or m3 as applicable | each batch, sampling event or dispatch | all on-site wastewater management | reporting facility | Sum by exact output identity and destination; do not net separate streams. | meter or scale calibration; dispatch record; treatment log |
cp_sanitation_and_wastewater_management_effluent_sampling_records | sanitation_and_wastewater_management | single effluent pollutant load | matched effluent flow and laboratory result | sample_id; pollutant_identity; concentration; concentration_unit; effluent_volume; discharge_compartment; sample_time; laboratory_method | Match representative pollutant concentration with the corresponding discharged effluent volume. | kg after conversion | each required sampling event and reporting-period calculation | all discharged treated or untreated effluent | reporting facility discharge point | Apply calc_wastewater_pollutant_load separately for each pollutant and receiving compartment. | accredited laboratory report; chain of custody; flow-meter calibration; calculation review |
cp_sanitation_and_wastewater_management_water_records | sanitation_and_wastewater_management | single-source water consumption or abstraction | water meter and allocation record | meter_id; water_source_identity; opening_reading; closing_reading; timestamp; stage_allocation_key | Read calibrated source-specific meters and reconcile shared meters to operating records. | m3 | continuous or each production shift | all operating and cleaning periods assigned to the stage | reporting facility and stated source point | Subtract opening from closing reading and allocate only with a documented causal key. | meter calibration; meter map; reading log; reconciliation |
cp_sanitation_and_wastewater_management_electricity_records | sanitation_and_wastewater_management | grid-electricity consumption | electricity meter and invoice record | meter_id; supplier; tariff_or_grid_identity; opening_reading; closing_reading; timestamp; stage_allocation_key | Reconcile stage submeter readings with facility invoices. | kWh | continuous or each production shift | all operating periods assigned to the stage | reporting facility | Calculate net consumption by meter and assign shared use with a disclosed causal key. | meter calibration; invoice reconciliation; submeter coverage |
cp_sanitation_and_wastewater_management_thermal_records | sanitation_and_wastewater_management | single purchased thermal carrier consumption | thermal meter and supplier record | carrier_identity; meter_id; opening_reading; closing_reading; temperature; pressure; enthalpy_basis; timestamp; allocation_key | Meter steam and hot water separately and convert only with recorded thermodynamic conditions. | MJ with original meter unit retained | continuous or each production shift | all operating periods assigned to the stage | reporting facility | Sum each carrier separately; never combine steam and hot water. | meter calibration; supplier record; conversion worksheet |
cp_sanitation_and_wastewater_management_fuel_records | sanitation_and_wastewater_management | single fuel consumption | fuel meter, invoice and stock-balance record | fuel_identity; opening_stock; receipts; closing_stock; meter_reading; lower_heating_value_if_used; timestamp; stage_allocation_key | Reconcile each fuel identity independently from tank, meter and invoice records. | kg or MJ as recorded | each delivery and monthly reconciliation | all fuel assigned to the stage | reporting facility | Opening stock plus receipts minus closing stock, separated by fuel identity. | tank calibration; invoices; stock reconciliation; fuel specification |
cp_sanitation_and_wastewater_management_air_emission_records | sanitation_and_wastewater_management | single direct combustion emission | stack measurement or fuel-based calculation record | pollutant_identity; stack_id; concentration; exhaust_flow; monitoring_time; fuel_identity; fuel_quantity; approved_factor_if_used; allocation_key | Use matched stack measurements where available; otherwise calculate separately for each pollutant and fuel from recorded activity and a disclosed factor. | kg | monitoring event and reporting-period calculation | all on-site combustion assigned to the stage | reporting facility direct releases | Apply calc_combustion_air_emissions by pollutant and stage; do not include upstream emissions. | monitoring report; fuel record; factor provenance; calculation review |
Raw downloads
These files are byte-identical to the canonical files for this revision in the repository.
Complete field inspector
Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.