TianGong PCR产品类别规则

Edible offal of pigs, fresh, chilled or frozen · Process: Sanitation and wastewater management (sanitation_and_wastewater_management)

Edible offal of pigs, fresh, chilled or frozen · Process: Sanitation and wastewater management (sanitation_and_wastewater_management): Record sodium hydroxide as one…

Lifecycle status
Candidate
Content maturity
Authored methodology
Current version
No published version
Readiness
Review required
Last updated

Methodology and translation states come from the source record; publishing this website does not change their review status.

Content languages

zh-CN · Aligned
Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:21153 · exact

Source

Process: Sanitation and wastewater management (sanitation_and_wastewater_management)

Inputs

Product flows
sodium hydroxide input (sanitation_and_wastewater_management_sodium_hydroxide)

Record sodium hydroxide as one formulation-identity input from chemical issue or dosing records; do not aggregate it with another substance.

  • Selected flow: Sodium hydroxide
  • Flow property / unit: Mass / kg
  • Amount rule: Measured formulated-product mass of sodium hydroxide used for cleaning, disinfection or treatment; record active concentration separately in the protocol fields.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_sanitation_and_wastewater_management_chemical_dosing_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
nitric acid input (sanitation_and_wastewater_management_nitric_acid)

Record nitric acid as one formulation-identity input from chemical issue or dosing records; do not aggregate it with another substance.

  • Selected flow: Nitric acid
  • Flow property / unit: Mass / kg
  • Amount rule: Measured formulated-product mass of nitric acid used for cleaning, disinfection or treatment; record active concentration separately in the protocol fields.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_sanitation_and_wastewater_management_chemical_dosing_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
sodium hypochlorite input (sanitation_and_wastewater_management_sodium_hypochlorite)

Record sodium hypochlorite as one formulation-identity input from chemical issue or dosing records; do not aggregate it with another substance.

  • Selected flow: Sodium hypochlorite
  • Flow property / unit: Mass / kg
  • Amount rule: Measured formulated-product mass of sodium hypochlorite used for cleaning, disinfection or treatment; record active concentration separately in the protocol fields.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_sanitation_and_wastewater_management_chemical_dosing_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
peracetic acid input (sanitation_and_wastewater_management_peracetic_acid)

Record peracetic acid as one formulation-identity input from chemical issue or dosing records; do not aggregate it with another substance.

  • Selected flow: Peracetic acid
  • Flow property / unit: Mass / kg
  • Amount rule: Measured formulated-product mass of peracetic acid used for cleaning, disinfection or treatment; record active concentration separately in the protocol fields.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_sanitation_and_wastewater_management_chemical_dosing_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
hydrogen peroxide input (sanitation_and_wastewater_management_hydrogen_peroxide)

Record hydrogen peroxide as one formulation-identity input from chemical issue or dosing records; do not aggregate it with another substance.

  • Selected flow: Hydrogen peroxide
  • Flow property / unit: Mass / kg
  • Amount rule: Measured formulated-product mass of hydrogen peroxide used for cleaning, disinfection or treatment; record active concentration separately in the protocol fields.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_sanitation_and_wastewater_management_chemical_dosing_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
chlorine dioxide input (sanitation_and_wastewater_management_chlorine_dioxide)

Record chlorine dioxide as one formulation-identity input from chemical issue or dosing records; do not aggregate it with another substance.

  • Selected flow: Chlorine dioxide
  • Flow property / unit: Mass / kg
  • Amount rule: Measured formulated-product mass of chlorine dioxide used for cleaning, disinfection or treatment; record active concentration separately in the protocol fields.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_sanitation_and_wastewater_management_chemical_dosing_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
ferric chloride input (sanitation_and_wastewater_management_ferric_chloride)

Record ferric chloride as one formulation-identity input from chemical issue or dosing records; do not aggregate it with another substance.

  • Selected flow: Ferric chloride
  • Flow property / unit: Mass / kg
  • Amount rule: Measured formulated-product mass of ferric chloride used for cleaning, disinfection or treatment; record active concentration separately in the protocol fields.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_sanitation_and_wastewater_management_chemical_dosing_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
calcium hydroxide input (sanitation_and_wastewater_management_calcium_hydroxide)

Record calcium hydroxide as one formulation-identity input from chemical issue or dosing records; do not aggregate it with another substance.

  • Selected flow: Calcium hydroxide
  • Flow property / unit: Mass / kg
  • Amount rule: Measured formulated-product mass of calcium hydroxide used for cleaning, disinfection or treatment; record active concentration separately in the protocol fields.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_sanitation_and_wastewater_management_chemical_dosing_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
polyacrylamide flocculant input (sanitation_and_wastewater_management_polyacrylamide_flocculant)

Record polyacrylamide flocculant as one formulation-identity input from chemical issue or dosing records; do not aggregate it with another substance.

  • Selected flow: Polyacrylamide flocculant
  • Flow property / unit: Mass / kg
  • Amount rule: Measured formulated-product mass of polyacrylamide flocculant used for cleaning, disinfection or treatment; record active concentration separately in the protocol fields.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_sanitation_and_wastewater_management_chemical_dosing_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Sanitation and wastewater management potable mains water (sanitation_and_wastewater_management_potable_mains_water)

Record only potable mains water delivered to sanitation and wastewater management as a separately metered product input.

  • Selected flow: Potable mains water
  • Flow property / unit: Volume / m3
  • Amount rule: Metered mains-water volume attributable to this stage; no category default is permitted.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_sanitation_and_wastewater_management_water_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Sanitation and wastewater management grid electricity (sanitation_and_wastewater_management_grid_electricity)

Record grid electricity crossing the facility boundary and consumed specifically by sanitation and wastewater management; keep this carrier separate from every other carrier.

  • Selected flow: Electricity, medium voltage, grid mix
  • Flow property / unit: Energy / kWh
  • Amount rule: Metered, invoiced or stock-balanced grid electricity attributable to this stage; no default is permitted.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_sanitation_and_wastewater_management_electricity_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Sanitation and wastewater management purchased steam (sanitation_and_wastewater_management_purchased_steam)

Record purchased steam crossing the facility boundary and consumed specifically by sanitation and wastewater management; keep this carrier separate from every other carrier.

  • Selected flow: Purchased steam
  • Flow property / unit: Energy / MJ
  • Amount rule: Metered, invoiced or stock-balanced purchased steam attributable to this stage; no default is permitted.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_sanitation_and_wastewater_management_thermal_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Sanitation and wastewater management purchased hot water (sanitation_and_wastewater_management_purchased_hot_water)

Record purchased hot water crossing the facility boundary and consumed specifically by sanitation and wastewater management; keep this carrier separate from every other carrier.

  • Selected flow: Purchased hot water
  • Flow property / unit: Energy / MJ
  • Amount rule: Metered, invoiced or stock-balanced purchased hot water attributable to this stage; no default is permitted.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_sanitation_and_wastewater_management_thermal_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Sanitation and wastewater management natural gas (sanitation_and_wastewater_management_natural_gas)

Record natural gas crossing the facility boundary and consumed specifically by sanitation and wastewater management; keep this carrier separate from every other carrier.

  • Selected flow: Natural gas
  • Flow property / unit: Energy / MJ
  • Amount rule: Metered, invoiced or stock-balanced natural gas attributable to this stage; no default is permitted.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_sanitation_and_wastewater_management_fuel_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Sanitation and wastewater management diesel fuel (sanitation_and_wastewater_management_diesel_fuel)

Record diesel fuel crossing the facility boundary and consumed specifically by sanitation and wastewater management; keep this carrier separate from every other carrier.

  • Selected flow: Diesel fuel
  • Flow property / unit: Mass / kg
  • Amount rule: Metered, invoiced or stock-balanced diesel fuel attributable to this stage; no default is permitted.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_sanitation_and_wastewater_management_fuel_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Sanitation and wastewater management liquefied petroleum gas (sanitation_and_wastewater_management_liquefied_petroleum_gas)

Record liquefied petroleum gas crossing the facility boundary and consumed specifically by sanitation and wastewater management; keep this carrier separate from every other carrier.

  • Selected flow: Liquefied petroleum gas
  • Flow property / unit: Mass / kg
  • Amount rule: Metered, invoiced or stock-balanced liquefied petroleum gas attributable to this stage; no default is permitted.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_sanitation_and_wastewater_management_fuel_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Waste flows
Pig-slaughter wastewater entering wastewater management (sanitation_and_wastewater_management_pig_slaughter_wastewater)

Record this source-separated wastewater only when the corresponding process branch is included and the stream enters on-site management.

  • Selected flow: Pig-slaughter wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Transferred wastewater volume reconciled to the originating process records.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_sanitation_and_wastewater_management_wastewater_balance_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Pig-organ-preparation wastewater entering wastewater management (sanitation_and_wastewater_management_pig_organ_preparation_wastewater)

Record this source-separated wastewater only when the corresponding process branch is included and the stream enters on-site management.

  • Selected flow: Pig-organ-preparation wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Transferred wastewater volume reconciled to the originating process records.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_sanitation_and_wastewater_management_wastewater_balance_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Fresh-pig-organ-conditioning wastewater entering wastewater management (sanitation_and_wastewater_management_fresh_pig_organ_conditioning_wastewater)

Record this source-separated wastewater only when the corresponding process branch is included and the stream enters on-site management.

  • Selected flow: Fresh-pig-organ-conditioning wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Transferred wastewater volume reconciled to the originating process records.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_sanitation_and_wastewater_management_wastewater_balance_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Chilled-pig-organ-conditioning wastewater entering wastewater management (sanitation_and_wastewater_management_chilled_pig_organ_conditioning_wastewater)

Record this source-separated wastewater only when the corresponding process branch is included and the stream enters on-site management.

  • Selected flow: Chilled-pig-organ-conditioning wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Transferred wastewater volume reconciled to the originating process records.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_sanitation_and_wastewater_management_wastewater_balance_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Frozen-pig-organ-conditioning wastewater entering wastewater management (sanitation_and_wastewater_management_frozen_pig_organ_conditioning_wastewater)

Record this source-separated wastewater only when the corresponding process branch is included and the stream enters on-site management.

  • Selected flow: Frozen-pig-organ-conditioning wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Transferred wastewater volume reconciled to the originating process records.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_sanitation_and_wastewater_management_wastewater_balance_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Elementary flows
Sanitation and wastewater management groundwater abstraction (sanitation_and_wastewater_management_water_ground)

Record direct groundwater abstraction crossing the elementary boundary for sanitation and wastewater management; do not duplicate mains water.

  • Selected flow: Water, ground
  • Flow property / unit: Volume / m3
  • Amount rule: Metered groundwater abstraction attributable to this stage.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_sanitation_and_wastewater_management_water_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Sanitation and wastewater management surface-water abstraction (sanitation_and_wastewater_management_water_surface)

Record direct surface-water abstraction crossing the elementary boundary for sanitation and wastewater management; do not duplicate mains water.

  • Selected flow: Water, surface
  • Flow property / unit: Volume / m3
  • Amount rule: Metered surface-water abstraction attributable to this stage.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_sanitation_and_wastewater_management_water_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279

Outputs

Product flows

No atomic exchange is defined for this direction and flow type.

Waste flows
Segregated high-strength pig-organ-processing wastewater (sanitation_and_wastewater_management_segregated_high_strength_pig_organ_wastewater)

Record segregated high-strength pig-organ-processing wastewater as a separate output with the actual treatment or disposal destination; never net it against another stream.

  • Selected flow: Segregated high-strength pig-organ-processing wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Measured volume and destination of segregated high-strength pig-organ-processing wastewater.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_sanitation_and_wastewater_management_wastewater_output_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Segregated low-strength pig-organ-processing wastewater (sanitation_and_wastewater_management_segregated_low_strength_pig_organ_wastewater)

Record segregated low-strength pig-organ-processing wastewater as a separate output with the actual treatment or disposal destination; never net it against another stream.

  • Selected flow: Segregated low-strength pig-organ-processing wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Measured volume and destination of segregated low-strength pig-organ-processing wastewater.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_sanitation_and_wastewater_management_wastewater_output_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Treated pig-organ-processing effluent (sanitation_and_wastewater_management_treated_pig_organ_effluent)

Record treated pig-organ-processing effluent as a separate output with the actual treatment or disposal destination; never net it against another stream.

  • Selected flow: Treated pig-organ-processing effluent
  • Flow property / unit: Volume / m3
  • Amount rule: Measured volume and destination of treated pig-organ-processing effluent.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_sanitation_and_wastewater_management_wastewater_output_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Wastewater-treatment sludge (sanitation_and_wastewater_management_wastewater_treatment_sludge)

Record wastewater-treatment sludge as a separate output with the actual treatment or disposal destination; never net it against another stream.

  • Selected flow: Wastewater-treatment sludge
  • Flow property / unit: Volume / m3
  • Amount rule: Measured volume and destination of wastewater-treatment sludge.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_sanitation_and_wastewater_management_wastewater_output_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Pig-organ-processing screen residue (sanitation_and_wastewater_management_pig_organ_screen_residue)

Record pig-organ-processing screen residue as a separate output with the actual treatment or disposal destination; never net it against another stream.

  • Selected flow: Pig-organ-processing screen residue
  • Flow property / unit: Mass / kg
  • Amount rule: Measured mass and destination of pig-organ-processing screen residue.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_sanitation_and_wastewater_management_wastewater_output_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Waste pig fat from grease separation (sanitation_and_wastewater_management_grease_separation_pig_fat)

Record waste pig fat from grease separation as a separate output with the actual treatment or disposal destination; never net it against another stream.

  • Selected flow: Waste pig fat from grease separation
  • Flow property / unit: Mass / kg
  • Amount rule: Measured mass and destination of waste pig fat from grease separation.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_sanitation_and_wastewater_management_wastewater_output_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Elementary flows
chemical oxygen demand discharge (sanitation_and_wastewater_management_chemical_oxygen_demand_water)

Record chemical oxygen demand discharged to the receiving water compartment as its own elementary exchange after any on-site treatment.

  • Selected flow: Chemical oxygen demand to water
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate discharged chemical oxygen demand under calc_wastewater_pollutant_load from matched effluent volume and concentration records; no default concentration is permitted.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_sanitation_and_wastewater_management_effluent_sampling_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
biochemical oxygen demand discharge (sanitation_and_wastewater_management_biochemical_oxygen_demand_water)

Record biochemical oxygen demand discharged to the receiving water compartment as its own elementary exchange after any on-site treatment.

  • Selected flow: Biochemical oxygen demand to water
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate discharged biochemical oxygen demand under calc_wastewater_pollutant_load from matched effluent volume and concentration records; no default concentration is permitted.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_sanitation_and_wastewater_management_effluent_sampling_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
suspended solids discharge (sanitation_and_wastewater_management_suspended_solids_water)

Record suspended solids discharged to the receiving water compartment as its own elementary exchange after any on-site treatment.

  • Selected flow: Suspended solids to water
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate discharged suspended solids under calc_wastewater_pollutant_load from matched effluent volume and concentration records; no default concentration is permitted.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_sanitation_and_wastewater_management_effluent_sampling_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
ammonium as nitrogen discharge (sanitation_and_wastewater_management_ammonium_as_n_water)

Record ammonium as nitrogen discharged to the receiving water compartment as its own elementary exchange after any on-site treatment.

  • Selected flow: Ammonium, as nitrogen, to water
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate discharged ammonium as nitrogen under calc_wastewater_pollutant_load from matched effluent volume and concentration records; no default concentration is permitted.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_sanitation_and_wastewater_management_effluent_sampling_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
nitrate as nitrogen discharge (sanitation_and_wastewater_management_nitrate_as_n_water)

Record nitrate as nitrogen discharged to the receiving water compartment as its own elementary exchange after any on-site treatment.

  • Selected flow: Nitrate, as nitrogen, to water
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate discharged nitrate as nitrogen under calc_wastewater_pollutant_load from matched effluent volume and concentration records; no default concentration is permitted.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_sanitation_and_wastewater_management_effluent_sampling_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
nitrite as nitrogen discharge (sanitation_and_wastewater_management_nitrite_as_n_water)

Record nitrite as nitrogen discharged to the receiving water compartment as its own elementary exchange after any on-site treatment.

  • Selected flow: Nitrite, as nitrogen, to water
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate discharged nitrite as nitrogen under calc_wastewater_pollutant_load from matched effluent volume and concentration records; no default concentration is permitted.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_sanitation_and_wastewater_management_effluent_sampling_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
phosphate as phosphorus discharge (sanitation_and_wastewater_management_phosphate_as_p_water)

Record phosphate as phosphorus discharged to the receiving water compartment as its own elementary exchange after any on-site treatment.

  • Selected flow: Phosphate, as phosphorus, to water
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate discharged phosphate as phosphorus under calc_wastewater_pollutant_load from matched effluent volume and concentration records; no default concentration is permitted.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_sanitation_and_wastewater_management_effluent_sampling_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
chloride discharge (sanitation_and_wastewater_management_chloride_water)

Record chloride discharged to the receiving water compartment as its own elementary exchange after any on-site treatment.

  • Selected flow: Chloride to water
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate discharged chloride under calc_wastewater_pollutant_load from matched effluent volume and concentration records; no default concentration is permitted.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_sanitation_and_wastewater_management_effluent_sampling_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Sanitation and wastewater management direct fossil carbon dioxide (sanitation_and_wastewater_management_carbon_dioxide_fossil_air)

Record only direct fossil carbon dioxide released by on-site combustion assigned to sanitation and wastewater management; exclude upstream energy-supply emissions.

  • Selected flow: Carbon dioxide, fossil, to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculated stage-specific direct emission under calc_combustion_air_emissions from monitored emissions or the recorded single-fuel input.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_sanitation_and_wastewater_management_air_emission_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Sanitation and wastewater management direct carbon monoxide (sanitation_and_wastewater_management_carbon_monoxide_air)

Record only direct carbon monoxide released by on-site combustion assigned to sanitation and wastewater management; exclude upstream energy-supply emissions.

  • Selected flow: Carbon monoxide to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculated stage-specific direct emission under calc_combustion_air_emissions from monitored emissions or the recorded single-fuel input.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_sanitation_and_wastewater_management_air_emission_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Sanitation and wastewater management direct fossil methane (sanitation_and_wastewater_management_methane_fossil_air)

Record only direct fossil methane released by on-site combustion assigned to sanitation and wastewater management; exclude upstream energy-supply emissions.

  • Selected flow: Methane, fossil, to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculated stage-specific direct emission under calc_combustion_air_emissions from monitored emissions or the recorded single-fuel input.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_sanitation_and_wastewater_management_air_emission_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Sanitation and wastewater management direct nitrous oxide (sanitation_and_wastewater_management_nitrous_oxide_air)

Record only direct nitrous oxide released by on-site combustion assigned to sanitation and wastewater management; exclude upstream energy-supply emissions.

  • Selected flow: Nitrous oxide to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculated stage-specific direct emission under calc_combustion_air_emissions from monitored emissions or the recorded single-fuel input.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_sanitation_and_wastewater_management_air_emission_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Sanitation and wastewater management direct nitric oxide (sanitation_and_wastewater_management_nitric_oxide_air)

Record only direct nitric oxide released by on-site combustion assigned to sanitation and wastewater management; exclude upstream energy-supply emissions.

  • Selected flow: Nitric oxide to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculated stage-specific direct emission under calc_combustion_air_emissions from monitored emissions or the recorded single-fuel input.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_sanitation_and_wastewater_management_air_emission_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Sanitation and wastewater management direct nitrogen dioxide (sanitation_and_wastewater_management_nitrogen_dioxide_air)

Record only direct nitrogen dioxide released by on-site combustion assigned to sanitation and wastewater management; exclude upstream energy-supply emissions.

  • Selected flow: Nitrogen dioxide to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculated stage-specific direct emission under calc_combustion_air_emissions from monitored emissions or the recorded single-fuel input.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_sanitation_and_wastewater_management_air_emission_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Sanitation and wastewater management direct sulfur dioxide (sanitation_and_wastewater_management_sulfur_dioxide_air)

Record only direct sulfur dioxide released by on-site combustion assigned to sanitation and wastewater management; exclude upstream energy-supply emissions.

  • Selected flow: Sulfur dioxide to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculated stage-specific direct emission under calc_combustion_air_emissions from monitored emissions or the recorded single-fuel input.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_sanitation_and_wastewater_management_air_emission_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Sanitation and wastewater management direct particulate matter below 2.5 micrometres (sanitation_and_wastewater_management_pm_below_2_5_air)

Record only direct particulate matter below 2.5 micrometres released by on-site combustion assigned to sanitation and wastewater management; exclude upstream energy-supply emissions.

  • Selected flow: Particulate matter below 2.5 micrometres to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculated stage-specific direct emission under calc_combustion_air_emissions from monitored emissions or the recorded single-fuel input.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_sanitation_and_wastewater_management_air_emission_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279
Sanitation and wastewater management direct particulate matter from 2.5 to 10 micrometres (sanitation_and_wastewater_management_pm_2_5_to_10_air)

Record only direct particulate matter from 2.5 to 10 micrometres released by on-site combustion assigned to sanitation and wastewater management; exclude upstream energy-supply emissions.

  • Selected flow: Particulate matter from 2.5 to 10 micrometres to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculated stage-specific direct emission under calc_combustion_air_emissions from monitored emissions or the recorded single-fuel input.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product after allocation to the declared organ and market state
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_sanitation_and_wastewater_management_air_emission_records
  • Sources: eu-jrc-sa-bref; eu-pef-2021-2279

7. Allocation and Co-product Handling

rule_idApplies toRulesource_ids
allocation_avoidforeground burden allocationAvoid allocation by subdividing independently measurable organ preparation, state conditioning, packaging, sanitation and treatment processes before applying any allocation key.eu-pef-2021-2279
allocation_direct_assignmentdirect process assignmentAssign metered electricity, thermal carriers, fuels, water, chemicals, packaging, wastes and emissions directly to the process and organ-state lot that caused them whenever records permit.eu-pef-2021-2279
allocation_slaughter_coproductsintegrated slaughterTreat the selected edible organ, pig carcass and each beneficially used named output as separate slaughter co-products; keep condemned or discarded outputs as wastes.eu-jrc-sa-bref; eu-pef-2021-2279
allocation_slaughter_relationresidual slaughter burdenFor residual inseparable slaughter burdens, use a documented physical causal relationship where it can be demonstrated; if it cannot, use reporting-period economic values for the exact co-products and disclose the sensitivity.eu-pef-2021-2279
allocation_no_defaultsallocation factorsCalculate allocation shares from foreground co-product quantities and, where used, contemporaneous values; do not insert a PCR default share or price.eu-pef-2021-2279
allocation_purchased_organpurchased-organ routeUse the supplier slaughter dataset's disclosed organ allocation once and do not reallocate those upstream burdens again in the receiving preparation process.eu-pef-2021-2279
allocation_waste_treatmentwaste treatmentAssign treatment burdens to the process generating each named waste or wastewater stream unless an explicitly documented facility-wide causal key is required; do not credit a waste as a co-product without a documented beneficial product destination.eu-jrc-sa-bref; eu-pef-2021-2279
allocation_mass_balanceallocation verificationReconcile allocated process totals to unallocated facility totals and document any unassigned difference, shared-service key and organ-state denominator.eu-pef-2021-2279

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_pig_receipt_and_ante_mortem_animal_receipt_recordspig_receipt_and_ante_mortemlive-pig receipt and ante-mortem dispositionweighbridge and inspection recordlot_id; supplier_id; receipt_time; animal_count; gross_mass; tare_mass; acceptance_status; dispositionReconcile calibrated weighbridge tickets with veterinary acceptance records by lot.kg and counteach received lotall lots in the reporting periodreporting facilitySum accepted and rejected masses separately; retain lot identity.weighbridge calibration; veterinary record; reconciliation sign-off
cp_pig_receipt_and_ante_mortem_receipt_waste_recordspig_receipt_and_ante_mortemreceipt waste mass and destinationwaste weighing and dispatch recordlot_id; waste_identity; measured_mass; container_tare; destination; dispatch_dateWeigh each named waste stream and reconcile dispatch records.kgeach lot or dispatchall included receipt operationsreporting facilitySum by exact waste identity and destination before allocation.scale calibration; waste transfer record; mass-balance review
cp_pig_receipt_and_ante_mortem_water_recordspig_receipt_and_ante_mortemsingle-source water consumption or abstractionwater meter and allocation recordmeter_id; water_source_identity; opening_reading; closing_reading; timestamp; stage_allocation_keyRead calibrated source-specific meters and reconcile shared meters to operating records.m3continuous or each production shiftall operating and cleaning periods assigned to the stagereporting facility and stated source pointSubtract opening from closing reading and allocate only with a documented causal key.meter calibration; meter map; reading log; reconciliation
cp_pig_receipt_and_ante_mortem_electricity_recordspig_receipt_and_ante_mortemgrid-electricity consumptionelectricity meter and invoice recordmeter_id; supplier; tariff_or_grid_identity; opening_reading; closing_reading; timestamp; stage_allocation_keyReconcile stage submeter readings with facility invoices.kWhcontinuous or each production shiftall operating periods assigned to the stagereporting facilityCalculate net consumption by meter and assign shared use with a disclosed causal key.meter calibration; invoice reconciliation; submeter coverage
cp_pig_receipt_and_ante_mortem_thermal_recordspig_receipt_and_ante_mortemsingle purchased thermal carrier consumptionthermal meter and supplier recordcarrier_identity; meter_id; opening_reading; closing_reading; temperature; pressure; enthalpy_basis; timestamp; allocation_keyMeter steam and hot water separately and convert only with recorded thermodynamic conditions.MJ with original meter unit retainedcontinuous or each production shiftall operating periods assigned to the stagereporting facilitySum each carrier separately; never combine steam and hot water.meter calibration; supplier record; conversion worksheet
cp_pig_receipt_and_ante_mortem_fuel_recordspig_receipt_and_ante_mortemsingle fuel consumptionfuel meter, invoice and stock-balance recordfuel_identity; opening_stock; receipts; closing_stock; meter_reading; lower_heating_value_if_used; timestamp; stage_allocation_keyReconcile each fuel identity independently from tank, meter and invoice records.kg or MJ as recordedeach delivery and monthly reconciliationall fuel assigned to the stagereporting facilityOpening stock plus receipts minus closing stock, separated by fuel identity.tank calibration; invoices; stock reconciliation; fuel specification
cp_pig_receipt_and_ante_mortem_air_emission_recordspig_receipt_and_ante_mortemsingle direct combustion emissionstack measurement or fuel-based calculation recordpollutant_identity; stack_id; concentration; exhaust_flow; monitoring_time; fuel_identity; fuel_quantity; approved_factor_if_used; allocation_keyUse matched stack measurements where available; otherwise calculate separately for each pollutant and fuel from recorded activity and a disclosed factor.kgmonitoring event and reporting-period calculationall on-site combustion assigned to the stagereporting facility direct releasesApply calc_combustion_air_emissions by pollutant and stage; do not include upstream emissions.monitoring report; fuel record; factor provenance; calculation review
cp_slaughter_and_organ_recovery_slaughter_mass_balanceslaughter_and_organ_recoveryslaughter input, recovered organ and co-product mass balancelot-specific slaughter yield recordlot_id; accepted_live_mass; exact_output_identity; gross_output_mass; tare_mass; edible_status; destination; timestampWeigh each organ and each co-product separately and reconcile to accepted live-pig input.kgeach slaughter lotall integrated-slaughter lots in the reporting periodreporting slaughter lineApply calc_slaughter_mass_balance by exact output identity; retain unaccounted-mass investigation.scale calibration; veterinary disposition; signed mass-balance reconciliation
cp_slaughter_and_organ_recovery_slaughter_waste_recordsslaughter_and_organ_recoverysingle slaughter waste mass and destinationwaste weighing and dispatch recordlot_id; exact_waste_identity; measured_mass; destination; treatment_route; timestampWeigh each named slaughter waste separately and reconcile with dispatch or treatment records.kgeach lot or dispatchall integrated-slaughter lotsreporting slaughter lineSum by exact waste identity and destination; prohibit product-waste double counting.scale calibration; disposition record; mass-balance reconciliation
cp_slaughter_and_organ_recovery_wastewater_recordsslaughter_and_organ_recoveryprocess-specific wastewater generationwastewater meter or batch wash recordsource_process; stream_identity; meter_reading; batch_volume; start_time; end_time; organ_identity; state_identityMeter the named process wastewater or calculate volume from verified batch wash records.m3each batch or continuous meter intervalall included production lotsreporting facilityApply the recorded source-process link and avoid double counting sanitation water.meter calibration; wash-cycle log; source-stream reconciliation
cp_slaughter_and_organ_recovery_water_recordsslaughter_and_organ_recoverysingle-source water consumption or abstractionwater meter and allocation recordmeter_id; water_source_identity; opening_reading; closing_reading; timestamp; stage_allocation_keyRead calibrated source-specific meters and reconcile shared meters to operating records.m3continuous or each production shiftall operating and cleaning periods assigned to the stagereporting facility and stated source pointSubtract opening from closing reading and allocate only with a documented causal key.meter calibration; meter map; reading log; reconciliation
cp_slaughter_and_organ_recovery_electricity_recordsslaughter_and_organ_recoverygrid-electricity consumptionelectricity meter and invoice recordmeter_id; supplier; tariff_or_grid_identity; opening_reading; closing_reading; timestamp; stage_allocation_keyReconcile stage submeter readings with facility invoices.kWhcontinuous or each production shiftall operating periods assigned to the stagereporting facilityCalculate net consumption by meter and assign shared use with a disclosed causal key.meter calibration; invoice reconciliation; submeter coverage
cp_slaughter_and_organ_recovery_thermal_recordsslaughter_and_organ_recoverysingle purchased thermal carrier consumptionthermal meter and supplier recordcarrier_identity; meter_id; opening_reading; closing_reading; temperature; pressure; enthalpy_basis; timestamp; allocation_keyMeter steam and hot water separately and convert only with recorded thermodynamic conditions.MJ with original meter unit retainedcontinuous or each production shiftall operating periods assigned to the stagereporting facilitySum each carrier separately; never combine steam and hot water.meter calibration; supplier record; conversion worksheet
cp_slaughter_and_organ_recovery_fuel_recordsslaughter_and_organ_recoverysingle fuel consumptionfuel meter, invoice and stock-balance recordfuel_identity; opening_stock; receipts; closing_stock; meter_reading; lower_heating_value_if_used; timestamp; stage_allocation_keyReconcile each fuel identity independently from tank, meter and invoice records.kg or MJ as recordedeach delivery and monthly reconciliationall fuel assigned to the stagereporting facilityOpening stock plus receipts minus closing stock, separated by fuel identity.tank calibration; invoices; stock reconciliation; fuel specification
cp_slaughter_and_organ_recovery_air_emission_recordsslaughter_and_organ_recoverysingle direct combustion emissionstack measurement or fuel-based calculation recordpollutant_identity; stack_id; concentration; exhaust_flow; monitoring_time; fuel_identity; fuel_quantity; approved_factor_if_used; allocation_keyUse matched stack measurements where available; otherwise calculate separately for each pollutant and fuel from recorded activity and a disclosed factor.kgmonitoring event and reporting-period calculationall on-site combustion assigned to the stagereporting facility direct releasesApply calc_combustion_air_emissions by pollutant and stage; do not include upstream emissions.monitoring report; fuel record; factor provenance; calculation review
cp_edible_organ_preparation_organ_mass_balanceedible_organ_preparationreceived, prepared and trimmed organ massorgan-lot mass-balance recordlot_id; exact_organ_identity; received_mass; prepared_mass; trimming_waste_mass; hold_or_drain_change; dispositionWeigh the one declared organ at receipt, after preparation and at each reject point.kgeach organ lotall prepared lotsreporting preparation lineApply calc_organ_preparation_mass_balance for one organ identity at a time.scale calibration; organ identity traceability; signed mass balance
cp_edible_organ_preparation_preparation_waste_recordsedible_organ_preparationorgan-specific preparation reject massreject weighing and destination recordlot_id; exact_organ_identity; reject_identity; measured_mass; destination; timestampWeigh trimmings separately for the declared organ and record final destination.kgeach organ lotall prepared lotsreporting preparation lineSum by exact organ and waste identity; reconcile to organ mass balance.scale calibration; disposition record; mass-balance review
cp_edible_organ_preparation_wastewater_recordsedible_organ_preparationprocess-specific wastewater generationwastewater meter or batch wash recordsource_process; stream_identity; meter_reading; batch_volume; start_time; end_time; organ_identity; state_identityMeter the named process wastewater or calculate volume from verified batch wash records.m3each batch or continuous meter intervalall included production lotsreporting facilityApply the recorded source-process link and avoid double counting sanitation water.meter calibration; wash-cycle log; source-stream reconciliation
cp_edible_organ_preparation_water_recordsedible_organ_preparationsingle-source water consumption or abstractionwater meter and allocation recordmeter_id; water_source_identity; opening_reading; closing_reading; timestamp; stage_allocation_keyRead calibrated source-specific meters and reconcile shared meters to operating records.m3continuous or each production shiftall operating and cleaning periods assigned to the stagereporting facility and stated source pointSubtract opening from closing reading and allocate only with a documented causal key.meter calibration; meter map; reading log; reconciliation
cp_edible_organ_preparation_electricity_recordsedible_organ_preparationgrid-electricity consumptionelectricity meter and invoice recordmeter_id; supplier; tariff_or_grid_identity; opening_reading; closing_reading; timestamp; stage_allocation_keyReconcile stage submeter readings with facility invoices.kWhcontinuous or each production shiftall operating periods assigned to the stagereporting facilityCalculate net consumption by meter and assign shared use with a disclosed causal key.meter calibration; invoice reconciliation; submeter coverage
cp_edible_organ_preparation_thermal_recordsedible_organ_preparationsingle purchased thermal carrier consumptionthermal meter and supplier recordcarrier_identity; meter_id; opening_reading; closing_reading; temperature; pressure; enthalpy_basis; timestamp; allocation_keyMeter steam and hot water separately and convert only with recorded thermodynamic conditions.MJ with original meter unit retainedcontinuous or each production shiftall operating periods assigned to the stagereporting facilitySum each carrier separately; never combine steam and hot water.meter calibration; supplier record; conversion worksheet
cp_edible_organ_preparation_fuel_recordsedible_organ_preparationsingle fuel consumptionfuel meter, invoice and stock-balance recordfuel_identity; opening_stock; receipts; closing_stock; meter_reading; lower_heating_value_if_used; timestamp; stage_allocation_keyReconcile each fuel identity independently from tank, meter and invoice records.kg or MJ as recordedeach delivery and monthly reconciliationall fuel assigned to the stagereporting facilityOpening stock plus receipts minus closing stock, separated by fuel identity.tank calibration; invoices; stock reconciliation; fuel specification
cp_edible_organ_preparation_air_emission_recordsedible_organ_preparationsingle direct combustion emissionstack measurement or fuel-based calculation recordpollutant_identity; stack_id; concentration; exhaust_flow; monitoring_time; fuel_identity; fuel_quantity; approved_factor_if_used; allocation_keyUse matched stack measurements where available; otherwise calculate separately for each pollutant and fuel from recorded activity and a disclosed factor.kgmonitoring event and reporting-period calculationall on-site combustion assigned to the stagereporting facility direct releasesApply calc_combustion_air_emissions by pollutant and stage; do not include upstream emissions.monitoring report; fuel record; factor provenance; calculation review
cp_fresh_state_conditioning_state_mass_balancefresh_state_conditioningsingle-organ state-conditioning mass balancestate-conditioning batch recordlot_id; exact_organ_identity; declared_state; input_mass; conforming_output_mass; reject_mass; start_time; end_time; temperature_recordWeigh one organ entering and leaving exactly one declared state branch and retain the temperature-time record.kg and degrees Celsius with timeeach state-conditioning lotall lots in the selected state branchreporting state-conditioning lineApply calc_state_conditioning_mass_balance only within the selected organ-state combination.scale calibration; calibrated temperature logger; branch-selection review
cp_fresh_state_conditioning_state_waste_recordsfresh_state_conditioningorgan-state-specific reject massreject weighing and destination recordlot_id; exact_organ_identity; declared_state; measured_reject_mass; rejection_reason; destinationWeigh rejected product separately for the exact organ-state combination.kgeach conditioning lotall lots in the selected state branchreporting state-conditioning lineSum by exact organ, state and destination; reconcile to the state mass balance.scale calibration; rejection record; destination evidence
cp_fresh_state_conditioning_wastewater_recordsfresh_state_conditioningprocess-specific wastewater generationwastewater meter or batch wash recordsource_process; stream_identity; meter_reading; batch_volume; start_time; end_time; organ_identity; state_identityMeter the named process wastewater or calculate volume from verified batch wash records.m3each batch or continuous meter intervalall included production lotsreporting facilityApply the recorded source-process link and avoid double counting sanitation water.meter calibration; wash-cycle log; source-stream reconciliation
cp_fresh_state_conditioning_water_recordsfresh_state_conditioningsingle-source water consumption or abstractionwater meter and allocation recordmeter_id; water_source_identity; opening_reading; closing_reading; timestamp; stage_allocation_keyRead calibrated source-specific meters and reconcile shared meters to operating records.m3continuous or each production shiftall operating and cleaning periods assigned to the stagereporting facility and stated source pointSubtract opening from closing reading and allocate only with a documented causal key.meter calibration; meter map; reading log; reconciliation
cp_fresh_state_conditioning_electricity_recordsfresh_state_conditioninggrid-electricity consumptionelectricity meter and invoice recordmeter_id; supplier; tariff_or_grid_identity; opening_reading; closing_reading; timestamp; stage_allocation_keyReconcile stage submeter readings with facility invoices.kWhcontinuous or each production shiftall operating periods assigned to the stagereporting facilityCalculate net consumption by meter and assign shared use with a disclosed causal key.meter calibration; invoice reconciliation; submeter coverage
cp_fresh_state_conditioning_thermal_recordsfresh_state_conditioningsingle purchased thermal carrier consumptionthermal meter and supplier recordcarrier_identity; meter_id; opening_reading; closing_reading; temperature; pressure; enthalpy_basis; timestamp; allocation_keyMeter steam and hot water separately and convert only with recorded thermodynamic conditions.MJ with original meter unit retainedcontinuous or each production shiftall operating periods assigned to the stagereporting facilitySum each carrier separately; never combine steam and hot water.meter calibration; supplier record; conversion worksheet
cp_fresh_state_conditioning_fuel_recordsfresh_state_conditioningsingle fuel consumptionfuel meter, invoice and stock-balance recordfuel_identity; opening_stock; receipts; closing_stock; meter_reading; lower_heating_value_if_used; timestamp; stage_allocation_keyReconcile each fuel identity independently from tank, meter and invoice records.kg or MJ as recordedeach delivery and monthly reconciliationall fuel assigned to the stagereporting facilityOpening stock plus receipts minus closing stock, separated by fuel identity.tank calibration; invoices; stock reconciliation; fuel specification
cp_fresh_state_conditioning_air_emission_recordsfresh_state_conditioningsingle direct combustion emissionstack measurement or fuel-based calculation recordpollutant_identity; stack_id; concentration; exhaust_flow; monitoring_time; fuel_identity; fuel_quantity; approved_factor_if_used; allocation_keyUse matched stack measurements where available; otherwise calculate separately for each pollutant and fuel from recorded activity and a disclosed factor.kgmonitoring event and reporting-period calculationall on-site combustion assigned to the stagereporting facility direct releasesApply calc_combustion_air_emissions by pollutant and stage; do not include upstream emissions.monitoring report; fuel record; factor provenance; calculation review
cp_chilled_state_conditioning_state_mass_balancechilled_state_conditioningsingle-organ state-conditioning mass balancestate-conditioning batch recordlot_id; exact_organ_identity; declared_state; input_mass; conforming_output_mass; reject_mass; start_time; end_time; temperature_recordWeigh one organ entering and leaving exactly one declared state branch and retain the temperature-time record.kg and degrees Celsius with timeeach state-conditioning lotall lots in the selected state branchreporting state-conditioning lineApply calc_state_conditioning_mass_balance only within the selected organ-state combination.scale calibration; calibrated temperature logger; branch-selection review
cp_chilled_state_conditioning_state_waste_recordschilled_state_conditioningorgan-state-specific reject massreject weighing and destination recordlot_id; exact_organ_identity; declared_state; measured_reject_mass; rejection_reason; destinationWeigh rejected product separately for the exact organ-state combination.kgeach conditioning lotall lots in the selected state branchreporting state-conditioning lineSum by exact organ, state and destination; reconcile to the state mass balance.scale calibration; rejection record; destination evidence
cp_chilled_state_conditioning_wastewater_recordschilled_state_conditioningprocess-specific wastewater generationwastewater meter or batch wash recordsource_process; stream_identity; meter_reading; batch_volume; start_time; end_time; organ_identity; state_identityMeter the named process wastewater or calculate volume from verified batch wash records.m3each batch or continuous meter intervalall included production lotsreporting facilityApply the recorded source-process link and avoid double counting sanitation water.meter calibration; wash-cycle log; source-stream reconciliation
cp_chilled_state_conditioning_water_recordschilled_state_conditioningsingle-source water consumption or abstractionwater meter and allocation recordmeter_id; water_source_identity; opening_reading; closing_reading; timestamp; stage_allocation_keyRead calibrated source-specific meters and reconcile shared meters to operating records.m3continuous or each production shiftall operating and cleaning periods assigned to the stagereporting facility and stated source pointSubtract opening from closing reading and allocate only with a documented causal key.meter calibration; meter map; reading log; reconciliation
cp_chilled_state_conditioning_electricity_recordschilled_state_conditioninggrid-electricity consumptionelectricity meter and invoice recordmeter_id; supplier; tariff_or_grid_identity; opening_reading; closing_reading; timestamp; stage_allocation_keyReconcile stage submeter readings with facility invoices.kWhcontinuous or each production shiftall operating periods assigned to the stagereporting facilityCalculate net consumption by meter and assign shared use with a disclosed causal key.meter calibration; invoice reconciliation; submeter coverage
cp_chilled_state_conditioning_thermal_recordschilled_state_conditioningsingle purchased thermal carrier consumptionthermal meter and supplier recordcarrier_identity; meter_id; opening_reading; closing_reading; temperature; pressure; enthalpy_basis; timestamp; allocation_keyMeter steam and hot water separately and convert only with recorded thermodynamic conditions.MJ with original meter unit retainedcontinuous or each production shiftall operating periods assigned to the stagereporting facilitySum each carrier separately; never combine steam and hot water.meter calibration; supplier record; conversion worksheet
cp_chilled_state_conditioning_fuel_recordschilled_state_conditioningsingle fuel consumptionfuel meter, invoice and stock-balance recordfuel_identity; opening_stock; receipts; closing_stock; meter_reading; lower_heating_value_if_used; timestamp; stage_allocation_keyReconcile each fuel identity independently from tank, meter and invoice records.kg or MJ as recordedeach delivery and monthly reconciliationall fuel assigned to the stagereporting facilityOpening stock plus receipts minus closing stock, separated by fuel identity.tank calibration; invoices; stock reconciliation; fuel specification
cp_chilled_state_conditioning_air_emission_recordschilled_state_conditioningsingle direct combustion emissionstack measurement or fuel-based calculation recordpollutant_identity; stack_id; concentration; exhaust_flow; monitoring_time; fuel_identity; fuel_quantity; approved_factor_if_used; allocation_keyUse matched stack measurements where available; otherwise calculate separately for each pollutant and fuel from recorded activity and a disclosed factor.kgmonitoring event and reporting-period calculationall on-site combustion assigned to the stagereporting facility direct releasesApply calc_combustion_air_emissions by pollutant and stage; do not include upstream emissions.monitoring report; fuel record; factor provenance; calculation review
cp_chilled_state_conditioning_refrigerant_recordschilled_state_conditioningsingle refrigerant charge, make-up, recovery and release balancerefrigeration service and stock recordequipment_id; exact_refrigerant_identity; opening_charge; make_up_mass; recovered_mass; closing_charge; service_date; supplier_compositionReconcile each installed refrigerant separately from service logs and stock records.kgeach service event and annual reconciliationall refrigeration equipment assigned to the stagereporting facilityApply calc_refrigerant_mass_balance per exact substance; use supplier composition for R-404A constituents.service certificate; calibrated cylinder scale; stock reconciliation; supplier specification
cp_frozen_state_conditioning_state_mass_balancefrozen_state_conditioningsingle-organ state-conditioning mass balancestate-conditioning batch recordlot_id; exact_organ_identity; declared_state; input_mass; conforming_output_mass; reject_mass; start_time; end_time; temperature_recordWeigh one organ entering and leaving exactly one declared state branch and retain the temperature-time record.kg and degrees Celsius with timeeach state-conditioning lotall lots in the selected state branchreporting state-conditioning lineApply calc_state_conditioning_mass_balance only within the selected organ-state combination.scale calibration; calibrated temperature logger; branch-selection review
cp_frozen_state_conditioning_state_waste_recordsfrozen_state_conditioningorgan-state-specific reject massreject weighing and destination recordlot_id; exact_organ_identity; declared_state; measured_reject_mass; rejection_reason; destinationWeigh rejected product separately for the exact organ-state combination.kgeach conditioning lotall lots in the selected state branchreporting state-conditioning lineSum by exact organ, state and destination; reconcile to the state mass balance.scale calibration; rejection record; destination evidence
cp_frozen_state_conditioning_wastewater_recordsfrozen_state_conditioningprocess-specific wastewater generationwastewater meter or batch wash recordsource_process; stream_identity; meter_reading; batch_volume; start_time; end_time; organ_identity; state_identityMeter the named process wastewater or calculate volume from verified batch wash records.m3each batch or continuous meter intervalall included production lotsreporting facilityApply the recorded source-process link and avoid double counting sanitation water.meter calibration; wash-cycle log; source-stream reconciliation
cp_frozen_state_conditioning_water_recordsfrozen_state_conditioningsingle-source water consumption or abstractionwater meter and allocation recordmeter_id; water_source_identity; opening_reading; closing_reading; timestamp; stage_allocation_keyRead calibrated source-specific meters and reconcile shared meters to operating records.m3continuous or each production shiftall operating and cleaning periods assigned to the stagereporting facility and stated source pointSubtract opening from closing reading and allocate only with a documented causal key.meter calibration; meter map; reading log; reconciliation
cp_frozen_state_conditioning_electricity_recordsfrozen_state_conditioninggrid-electricity consumptionelectricity meter and invoice recordmeter_id; supplier; tariff_or_grid_identity; opening_reading; closing_reading; timestamp; stage_allocation_keyReconcile stage submeter readings with facility invoices.kWhcontinuous or each production shiftall operating periods assigned to the stagereporting facilityCalculate net consumption by meter and assign shared use with a disclosed causal key.meter calibration; invoice reconciliation; submeter coverage
cp_frozen_state_conditioning_thermal_recordsfrozen_state_conditioningsingle purchased thermal carrier consumptionthermal meter and supplier recordcarrier_identity; meter_id; opening_reading; closing_reading; temperature; pressure; enthalpy_basis; timestamp; allocation_keyMeter steam and hot water separately and convert only with recorded thermodynamic conditions.MJ with original meter unit retainedcontinuous or each production shiftall operating periods assigned to the stagereporting facilitySum each carrier separately; never combine steam and hot water.meter calibration; supplier record; conversion worksheet
cp_frozen_state_conditioning_fuel_recordsfrozen_state_conditioningsingle fuel consumptionfuel meter, invoice and stock-balance recordfuel_identity; opening_stock; receipts; closing_stock; meter_reading; lower_heating_value_if_used; timestamp; stage_allocation_keyReconcile each fuel identity independently from tank, meter and invoice records.kg or MJ as recordedeach delivery and monthly reconciliationall fuel assigned to the stagereporting facilityOpening stock plus receipts minus closing stock, separated by fuel identity.tank calibration; invoices; stock reconciliation; fuel specification
cp_frozen_state_conditioning_air_emission_recordsfrozen_state_conditioningsingle direct combustion emissionstack measurement or fuel-based calculation recordpollutant_identity; stack_id; concentration; exhaust_flow; monitoring_time; fuel_identity; fuel_quantity; approved_factor_if_used; allocation_keyUse matched stack measurements where available; otherwise calculate separately for each pollutant and fuel from recorded activity and a disclosed factor.kgmonitoring event and reporting-period calculationall on-site combustion assigned to the stagereporting facility direct releasesApply calc_combustion_air_emissions by pollutant and stage; do not include upstream emissions.monitoring report; fuel record; factor provenance; calculation review
cp_frozen_state_conditioning_refrigerant_recordsfrozen_state_conditioningsingle refrigerant charge, make-up, recovery and release balancerefrigeration service and stock recordequipment_id; exact_refrigerant_identity; opening_charge; make_up_mass; recovered_mass; closing_charge; service_date; supplier_compositionReconcile each installed refrigerant separately from service logs and stock records.kgeach service event and annual reconciliationall refrigeration equipment assigned to the stagereporting facilityApply calc_refrigerant_mass_balance per exact substance; use supplier composition for R-404A constituents.service certificate; calibrated cylinder scale; stock reconciliation; supplier specification
cp_packaging_storage_and_release_release_mass_recordspackaging_storage_and_releaseone organ-state product entering packaging and releaselot release and weighing recordlot_id; exact_organ_identity; declared_state; input_net_mass; reject_mass; released_net_mass; packaging_mass; release_timeWeigh the exact organ-state product and packaging separately at release.kgeach released lotall reference-product lotsreporting packaging and release lineApply calc_reference_product_normalization to net product mass only.scale calibration; lot release certificate; product-packaging tare record
cp_packaging_storage_and_release_release_waste_recordspackaging_storage_and_releaseorgan-state-specific release reject massrelease reject and destination recordlot_id; exact_organ_identity; declared_state; reject_mass; rejection_reason; destinationWeigh release rejects separately for the exact organ-state combination.kgeach released lotall reference-product lotsreporting packaging and release lineSum by exact organ, state and destination; reconcile with released mass.scale calibration; release record; destination evidence
cp_packaging_storage_and_release_packaging_bom_recordspackaging_storage_and_releasesingle packaging component inputproduct-specific packaging bill of materials and issue recordlot_id; packaging_component_identity; supplier; item_count; unit_mass; total_mass; recycled_content_if_claimedReconcile issued packaging with a product-specific bill of materials and measured or supplier-declared unit mass.kg and item counteach packaging specification and released lotall packaging used for the reference productreporting packaging lineCalculate mass separately for each named component; exclude packaging from reference-product net mass.approved BOM; supplier specification; scale or item-count reconciliation
cp_packaging_storage_and_release_packaging_waste_recordspackaging_storage_and_releasesingle packaging-component waste masspackaging reject and waste dispatch recordlot_id; exact_component_identity; measured_waste_mass; destination; timestampWeigh discarded packaging separately by exact component identity.kgeach shift or dispatchall packaging operationsreporting packaging lineSum by exact component and destination; reconcile with packaging issued.scale calibration; dispatch record; packaging mass balance
cp_packaging_storage_and_release_reference_release_recordspackaging_storage_and_releasereference-product net release and normalizationfinal release and normalization recordlot_id; exact_organ_identity; declared_state; conforming_net_mass; packaging_mass; reference_normalization_factor; release_specificationVerify one organ and one state, exclude packaging mass, then normalize the conforming net mass to 1 kg.kgeach released lot and reporting-period aggregationall reference-product lotsreporting packaging and release lineApply calc_reference_product_normalization without pooling organ or state identities.release certificate; calibrated scale; branch-selection check; normalization worksheet
cp_packaging_storage_and_release_water_recordspackaging_storage_and_releasesingle-source water consumption or abstractionwater meter and allocation recordmeter_id; water_source_identity; opening_reading; closing_reading; timestamp; stage_allocation_keyRead calibrated source-specific meters and reconcile shared meters to operating records.m3continuous or each production shiftall operating and cleaning periods assigned to the stagereporting facility and stated source pointSubtract opening from closing reading and allocate only with a documented causal key.meter calibration; meter map; reading log; reconciliation
cp_packaging_storage_and_release_electricity_recordspackaging_storage_and_releasegrid-electricity consumptionelectricity meter and invoice recordmeter_id; supplier; tariff_or_grid_identity; opening_reading; closing_reading; timestamp; stage_allocation_keyReconcile stage submeter readings with facility invoices.kWhcontinuous or each production shiftall operating periods assigned to the stagereporting facilityCalculate net consumption by meter and assign shared use with a disclosed causal key.meter calibration; invoice reconciliation; submeter coverage
cp_packaging_storage_and_release_thermal_recordspackaging_storage_and_releasesingle purchased thermal carrier consumptionthermal meter and supplier recordcarrier_identity; meter_id; opening_reading; closing_reading; temperature; pressure; enthalpy_basis; timestamp; allocation_keyMeter steam and hot water separately and convert only with recorded thermodynamic conditions.MJ with original meter unit retainedcontinuous or each production shiftall operating periods assigned to the stagereporting facilitySum each carrier separately; never combine steam and hot water.meter calibration; supplier record; conversion worksheet
cp_packaging_storage_and_release_fuel_recordspackaging_storage_and_releasesingle fuel consumptionfuel meter, invoice and stock-balance recordfuel_identity; opening_stock; receipts; closing_stock; meter_reading; lower_heating_value_if_used; timestamp; stage_allocation_keyReconcile each fuel identity independently from tank, meter and invoice records.kg or MJ as recordedeach delivery and monthly reconciliationall fuel assigned to the stagereporting facilityOpening stock plus receipts minus closing stock, separated by fuel identity.tank calibration; invoices; stock reconciliation; fuel specification
cp_packaging_storage_and_release_air_emission_recordspackaging_storage_and_releasesingle direct combustion emissionstack measurement or fuel-based calculation recordpollutant_identity; stack_id; concentration; exhaust_flow; monitoring_time; fuel_identity; fuel_quantity; approved_factor_if_used; allocation_keyUse matched stack measurements where available; otherwise calculate separately for each pollutant and fuel from recorded activity and a disclosed factor.kgmonitoring event and reporting-period calculationall on-site combustion assigned to the stagereporting facility direct releasesApply calc_combustion_air_emissions by pollutant and stage; do not include upstream emissions.monitoring report; fuel record; factor provenance; calculation review
cp_packaging_storage_and_release_refrigerant_recordspackaging_storage_and_releasesingle refrigerant charge, make-up, recovery and release balancerefrigeration service and stock recordequipment_id; exact_refrigerant_identity; opening_charge; make_up_mass; recovered_mass; closing_charge; service_date; supplier_compositionReconcile each installed refrigerant separately from service logs and stock records.kgeach service event and annual reconciliationall refrigeration equipment assigned to the stagereporting facilityApply calc_refrigerant_mass_balance per exact substance; use supplier composition for R-404A constituents.service certificate; calibrated cylinder scale; stock reconciliation; supplier specification
cp_sanitation_and_wastewater_management_wastewater_balance_recordssanitation_and_wastewater_managementsource-separated wastewater transfer balancesource-stream meter and transfer recordsource_process; exact_stream_identity; source_volume; transferred_volume; bypass_volume; destination; timestampReconcile each named source stream between generation and on-site management.m3each batch or continuous intervalall included wastewater streamsreporting facilityBalance each source stream separately and investigate discrepancies.meter calibration; flow diagram; transfer reconciliation
cp_sanitation_and_wastewater_management_chemical_dosing_recordssanitation_and_wastewater_managementsingle cleaning, disinfection or treatment chemical dosechemical issue and dosing recordexact_chemical_identity; formulation_concentration; batch_or_meter_id; issued_mass; returned_mass; dose_time; target_operationReconcile each formulation identity separately from store issue, return and dosing records.kg formulated producteach dose and monthly stock reconciliationall cleaning, disinfection and on-site treatment operationsreporting facilityIssued minus returned mass by exact formulation; retain active concentration as metadata.supplier SDS or specification; dosing calibration; stock reconciliation
cp_sanitation_and_wastewater_management_wastewater_output_recordssanitation_and_wastewater_managementsingle wastewater-treatment output mass or volumetreatment output and destination recordexact_output_identity; measured_mass_or_volume; sampling_or_dispatch_time; destination; treatment_statusMeasure each output independently at the treatment or dispatch point.kg or m3 as applicableeach batch, sampling event or dispatchall on-site wastewater managementreporting facilitySum by exact output identity and destination; do not net separate streams.meter or scale calibration; dispatch record; treatment log
cp_sanitation_and_wastewater_management_effluent_sampling_recordssanitation_and_wastewater_managementsingle effluent pollutant loadmatched effluent flow and laboratory resultsample_id; pollutant_identity; concentration; concentration_unit; effluent_volume; discharge_compartment; sample_time; laboratory_methodMatch representative pollutant concentration with the corresponding discharged effluent volume.kg after conversioneach required sampling event and reporting-period calculationall discharged treated or untreated effluentreporting facility discharge pointApply calc_wastewater_pollutant_load separately for each pollutant and receiving compartment.accredited laboratory report; chain of custody; flow-meter calibration; calculation review
cp_sanitation_and_wastewater_management_water_recordssanitation_and_wastewater_managementsingle-source water consumption or abstractionwater meter and allocation recordmeter_id; water_source_identity; opening_reading; closing_reading; timestamp; stage_allocation_keyRead calibrated source-specific meters and reconcile shared meters to operating records.m3continuous or each production shiftall operating and cleaning periods assigned to the stagereporting facility and stated source pointSubtract opening from closing reading and allocate only with a documented causal key.meter calibration; meter map; reading log; reconciliation
cp_sanitation_and_wastewater_management_electricity_recordssanitation_and_wastewater_managementgrid-electricity consumptionelectricity meter and invoice recordmeter_id; supplier; tariff_or_grid_identity; opening_reading; closing_reading; timestamp; stage_allocation_keyReconcile stage submeter readings with facility invoices.kWhcontinuous or each production shiftall operating periods assigned to the stagereporting facilityCalculate net consumption by meter and assign shared use with a disclosed causal key.meter calibration; invoice reconciliation; submeter coverage
cp_sanitation_and_wastewater_management_thermal_recordssanitation_and_wastewater_managementsingle purchased thermal carrier consumptionthermal meter and supplier recordcarrier_identity; meter_id; opening_reading; closing_reading; temperature; pressure; enthalpy_basis; timestamp; allocation_keyMeter steam and hot water separately and convert only with recorded thermodynamic conditions.MJ with original meter unit retainedcontinuous or each production shiftall operating periods assigned to the stagereporting facilitySum each carrier separately; never combine steam and hot water.meter calibration; supplier record; conversion worksheet
cp_sanitation_and_wastewater_management_fuel_recordssanitation_and_wastewater_managementsingle fuel consumptionfuel meter, invoice and stock-balance recordfuel_identity; opening_stock; receipts; closing_stock; meter_reading; lower_heating_value_if_used; timestamp; stage_allocation_keyReconcile each fuel identity independently from tank, meter and invoice records.kg or MJ as recordedeach delivery and monthly reconciliationall fuel assigned to the stagereporting facilityOpening stock plus receipts minus closing stock, separated by fuel identity.tank calibration; invoices; stock reconciliation; fuel specification
cp_sanitation_and_wastewater_management_air_emission_recordssanitation_and_wastewater_managementsingle direct combustion emissionstack measurement or fuel-based calculation recordpollutant_identity; stack_id; concentration; exhaust_flow; monitoring_time; fuel_identity; fuel_quantity; approved_factor_if_used; allocation_keyUse matched stack measurements where available; otherwise calculate separately for each pollutant and fuel from recorded activity and a disclosed factor.kgmonitoring event and reporting-period calculationall on-site combustion assigned to the stagereporting facility direct releasesApply calc_combustion_air_emissions by pollutant and stage; do not include upstream emissions.monitoring report; fuel record; factor provenance; calculation review

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page

Process: Sanitation and wastewater management (sanitation_and_wastewater_management)InputsProduct flowssodium hydroxide input (sanitation_and_wastewater_management_sodium_hydroxide)nitric acid input (sanitation_and_wastewater_management_nitric_acid)sodium hypochlorite input (sanitation_and_wastewater_management_sodium_hypochlorite)peracetic acid input (sanitation_and_wastewater_management_peracetic_acid)hydrogen peroxide input (sanitation_and_wastewater_management_hydrogen_peroxide)chlorine dioxide input (sanitation_and_wastewater_management_chlorine_dioxide)ferric chloride input (sanitation_and_wastewater_management_ferric_chloride)calcium hydroxide input (sanitation_and_wastewater_management_calcium_hydroxide)polyacrylamide flocculant input (sanitation_and_wastewater_management_polyacrylamide_flocculant)Sanitation and wastewater management potable mains water (sanitation_and_wastewater_management_potable_mains_water)Sanitation and wastewater management grid electricity (sanitation_and_wastewater_management_grid_electricity)Sanitation and wastewater management purchased steam (sanitation_and_wastewater_management_purchased_steam)Sanitation and wastewater management purchased hot water (sanitation_and_wastewater_management_purchased_hot_water)Sanitation and wastewater management natural gas (sanitation_and_wastewater_management_natural_gas)Sanitation and wastewater management diesel fuel (sanitation_and_wastewater_management_diesel_fuel)Sanitation and wastewater management liquefied petroleum gas (sanitation_and_wastewater_management_liquefied_petroleum_gas)Waste flowsPig-slaughter wastewater entering wastewater management (sanitation_and_wastewater_management_pig_slaughter_wastewater)Pig-organ-preparation wastewater entering wastewater management (sanitation_and_wastewater_management_pig_organ_preparation_wastewater)Fresh-pig-organ-conditioning wastewater entering wastewater management (sanitation_and_wastewater_management_fresh_pig_organ_conditioning_wastewater)Chilled-pig-organ-conditioning wastewater entering wastewater management (sanitation_and_wastewater_management_chilled_pig_organ_conditioning_wastewater)Frozen-pig-organ-conditioning wastewater entering wastewater management (sanitation_and_wastewater_management_frozen_pig_organ_conditioning_wastewater)Elementary flowsSanitation and wastewater management groundwater abstraction (sanitation_and_wastewater_management_water_ground)Sanitation and wastewater management surface-water abstraction (sanitation_and_wastewater_management_water_surface)OutputsProduct flowsWaste flowsSegregated high-strength pig-organ-processing wastewater (sanitation_and_wastewater_management_segregated_high_strength_pig_organ_wastewater)Segregated low-strength pig-organ-processing wastewater (sanitation_and_wastewater_management_segregated_low_strength_pig_organ_wastewater)Treated pig-organ-processing effluent (sanitation_and_wastewater_management_treated_pig_organ_effluent)Wastewater-treatment sludge (sanitation_and_wastewater_management_wastewater_treatment_sludge)Pig-organ-processing screen residue (sanitation_and_wastewater_management_pig_organ_screen_residue)Waste pig fat from grease separation (sanitation_and_wastewater_management_grease_separation_pig_fat)Elementary flowschemical oxygen demand discharge (sanitation_and_wastewater_management_chemical_oxygen_demand_water)biochemical oxygen demand discharge (sanitation_and_wastewater_management_biochemical_oxygen_demand_water)suspended solids discharge (sanitation_and_wastewater_management_suspended_solids_water)ammonium as nitrogen discharge (sanitation_and_wastewater_management_ammonium_as_n_water)nitrate as nitrogen discharge (sanitation_and_wastewater_management_nitrate_as_n_water)nitrite as nitrogen discharge (sanitation_and_wastewater_management_nitrite_as_n_water)phosphate as phosphorus discharge (sanitation_and_wastewater_management_phosphate_as_p_water)chloride discharge (sanitation_and_wastewater_management_chloride_water)Sanitation and wastewater management direct fossil carbon dioxide (sanitation_and_wastewater_management_carbon_dioxide_fossil_air)Sanitation and wastewater management direct carbon monoxide (sanitation_and_wastewater_management_carbon_monoxide_air)Sanitation and wastewater management direct fossil methane (sanitation_and_wastewater_management_methane_fossil_air)Sanitation and wastewater management direct nitrous oxide (sanitation_and_wastewater_management_nitrous_oxide_air)Sanitation and wastewater management direct nitric oxide (sanitation_and_wastewater_management_nitric_oxide_air)Sanitation and wastewater management direct nitrogen dioxide (sanitation_and_wastewater_management_nitrogen_dioxide_air)Sanitation and wastewater management direct sulfur dioxide (sanitation_and_wastewater_management_sulfur_dioxide_air)Sanitation and wastewater management direct particulate matter below 2.5 micrometres (sanitation_and_wastewater_management_pm_below_2_5_air)Sanitation and wastewater management direct particulate matter from 2.5 to 10 micrometres (sanitation_and_wastewater_management_pm_2_5_to_10_air)7. Allocation and Co-product Handling8. Foreground Data Collection, Calculation, and Quality RulesData Collection Protocols