TianGong PCR产品类别规则

Groats, meal and pellets of wheat and other cereals · Process: Dust collection and control (dust_collection_control)

Groats, meal and pellets of wheat and other cereals · Process: Dust collection and control (dust_collection_control): Grid electricity, medium voltage is recorded as…

Lifecycle status
Candidate
Content maturity
Authored methodology
Current version
No published version
Readiness
Review required
Last updated

Methodology and translation states come from the source record; publishing this website does not change their review status.

Content languages

zh-CN · Aligned
Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:23130 · exact

Source

Process: Dust collection and control (dust_collection_control)

Inputs

Product flows
Supply grid electricity to dust control (dust_control_grid_electricity)

Grid electricity, medium voltage is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Grid electricity, medium voltage
  • Flow property / unit: Energy / kWh
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_dust_inputs
  • Sources: us-epa-ap42-grain-2003, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Grid electricity, medium voltage physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Supply compressed air to fabric-filter cleaning (dust_control_compressed_air)

Compressed air is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Compressed air
  • Flow property / unit: Volume / m3
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_dust_inputs
  • Sources: us-epa-ap42-grain-2003, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Compressed air physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Supply polyester needle-felt filter fabric (dust_control_filter_fabric)

Polyester needle-felt filter fabric is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Polyester needle-felt filter fabric
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_dust_inputs
  • Sources: us-epa-ap42-grain-2003, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Polyester needle-felt filter fabric physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Supply process water to wet scrubber (dust_control_scrubber_water)

Process water for wet scrubbing is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Process water for wet scrubbing
  • Flow property / unit: Volume / m3
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_dust_inputs
  • Sources: us-epa-ap42-grain-2003, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Process water for wet scrubbing physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Waste flows

No atomic exchange is declared in this group for the current PCR.

Elementary flows

No atomic exchange is declared in this group for the current PCR.

Outputs

Product flows

No atomic exchange is declared in this group for the current PCR.

Waste flows
Remove captured common wheat dust (captured_dust_common_wheat)

Captured common wheat dust is recorded as one atomic output waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Captured common wheat dust
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_dust_outputs
  • Sources: us-epa-ap42-grain-2003, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Captured common wheat dust physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Remove captured durum wheat dust (captured_dust_durum_wheat)

Captured durum wheat dust is recorded as one atomic output waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Captured durum wheat dust
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_dust_outputs
  • Sources: us-epa-ap42-grain-2003, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Captured durum wheat dust physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Remove captured rye dust (captured_dust_rye)

Captured rye dust is recorded as one atomic output waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Captured rye dust
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_dust_outputs
  • Sources: us-epa-ap42-grain-2003, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Captured rye dust physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Remove captured barley dust (captured_dust_barley)

Captured barley dust is recorded as one atomic output waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Captured barley dust
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_dust_outputs
  • Sources: us-epa-ap42-grain-2003, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Captured barley dust physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Remove captured oats dust (captured_dust_oats)

Captured oats dust is recorded as one atomic output waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Captured oats dust
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_dust_outputs
  • Sources: us-epa-ap42-grain-2003, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Captured oats dust physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Remove captured maize dust (captured_dust_maize)

Captured maize dust is recorded as one atomic output waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Captured maize dust
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_dust_outputs
  • Sources: us-epa-ap42-grain-2003, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Captured maize dust physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Remove captured sorghum dust (captured_dust_sorghum)

Captured sorghum dust is recorded as one atomic output waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Captured sorghum dust
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_dust_outputs
  • Sources: us-epa-ap42-grain-2003, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Captured sorghum dust physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Remove captured pearl millet dust (captured_dust_pearl_millet)

Captured pearl millet dust is recorded as one atomic output waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Captured pearl millet dust
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_dust_outputs
  • Sources: us-epa-ap42-grain-2003, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Captured pearl millet dust physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Remove spent polyester filter fabric (spent_filter_fabric)

Spent polyester filter fabric is recorded as one atomic output waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Spent polyester filter fabric
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_dust_outputs
  • Sources: us-epa-ap42-grain-2003, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Spent polyester filter fabric physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Remove grain-dust scrubber wastewater (scrubber_wastewater)

Grain-dust scrubber wastewater is recorded as one atomic output waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Grain-dust scrubber wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_dust_outputs
  • Sources: us-epa-ap42-grain-2003, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Grain-dust scrubber wastewater physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Elementary flows
Release residual particulate matter below 10 µm (controlled_pm10)

Particulate matter below 10 µm to air is recorded as one atomic output elementary exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Particulate matter below 10 µm to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate the batch-attributable amount from the foreground records defined by the linked protocol.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_dust_outputs
  • Sources: us-epa-ap42-grain-2003, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Particulate matter below 10 µm to air physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Release residual particulate matter below 2.5 µm (controlled_pm25)

Particulate matter below 2.5 µm to air is recorded as one atomic output elementary exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Particulate matter below 2.5 µm to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate the batch-attributable amount from the foreground records defined by the linked protocol.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_dust_outputs
  • Sources: us-epa-ap42-grain-2003, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Particulate matter below 2.5 µm to air physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.

Process: Hygiene and equipment cleaning (hygiene_cleaning)

Inputs

Product flows
Supply grid electricity to hygiene cleaning (hygiene_grid_electricity)

Grid electricity, medium voltage is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Grid electricity, medium voltage
  • Flow property / unit: Energy / kWh
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_hygiene_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Grid electricity, medium voltage physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Supply compressed air to dry cleaning (hygiene_compressed_air)

Compressed air is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Compressed air
  • Flow property / unit: Volume / m3
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_hygiene_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Compressed air physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Supply process water to hygiene cleaning (hygiene_process_water)

Process water for hygiene cleaning is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Process water for hygiene cleaning
  • Flow property / unit: Volume / m3
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_hygiene_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Process water for hygiene cleaning physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Supply purchased hot water to hygiene cleaning (hygiene_purchased_hot_water)

Purchased hot water is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Purchased hot water
  • Flow property / unit: Energy / MJ
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_hygiene_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Purchased hot water physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Supply purchased steam to hygiene cleaning (hygiene_purchased_steam)

Purchased steam is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Purchased steam
  • Flow property / unit: Energy / MJ
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_hygiene_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Purchased steam physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Supply sodium hydroxide (hygiene_sodium_hydroxide)

Sodium hydroxide is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Sodium hydroxide
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_hygiene_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Sodium hydroxide physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Supply nitric acid (hygiene_nitric_acid)

Nitric acid is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Nitric acid
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_hygiene_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Nitric acid physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Supply phosphoric acid (hygiene_phosphoric_acid)

Phosphoric acid is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Phosphoric acid
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_hygiene_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Phosphoric acid physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Supply peracetic acid (hygiene_peracetic_acid)

Peracetic acid is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Peracetic acid
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_hygiene_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Peracetic acid physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Supply sodium hypochlorite (hygiene_sodium_hypochlorite)

Sodium hypochlorite is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Sodium hypochlorite
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_hygiene_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Sodium hypochlorite physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Waste flows

No atomic exchange is declared in this group for the current PCR.

Elementary flows

No atomic exchange is declared in this group for the current PCR.

Outputs

Product flows

No atomic exchange is declared in this group for the current PCR.

Waste flows
Remove common wheat dry sweepings (dry_sweepings_common_wheat)

Common wheat dry sweepings is recorded as one atomic output waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Common wheat dry sweepings
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_hygiene_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Common wheat dry sweepings physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Remove durum wheat dry sweepings (dry_sweepings_durum_wheat)

Durum wheat dry sweepings is recorded as one atomic output waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Durum wheat dry sweepings
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_hygiene_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Durum wheat dry sweepings physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Remove rye dry sweepings (dry_sweepings_rye)

Rye dry sweepings is recorded as one atomic output waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Rye dry sweepings
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_hygiene_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Rye dry sweepings physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Remove barley dry sweepings (dry_sweepings_barley)

Barley dry sweepings is recorded as one atomic output waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Barley dry sweepings
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_hygiene_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Barley dry sweepings physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Remove oats dry sweepings (dry_sweepings_oats)

Oats dry sweepings is recorded as one atomic output waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Oats dry sweepings
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_hygiene_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Oats dry sweepings physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Remove maize dry sweepings (dry_sweepings_maize)

Maize dry sweepings is recorded as one atomic output waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Maize dry sweepings
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_hygiene_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Maize dry sweepings physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Remove sorghum dry sweepings (dry_sweepings_sorghum)

Sorghum dry sweepings is recorded as one atomic output waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Sorghum dry sweepings
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_hygiene_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Sorghum dry sweepings physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Remove pearl millet dry sweepings (dry_sweepings_pearl_millet)

Pearl millet dry sweepings is recorded as one atomic output waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Pearl millet dry sweepings
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_hygiene_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Pearl millet dry sweepings physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Remove hygiene cleaning wastewater (hygiene_wastewater)

Hygiene cleaning wastewater is recorded as one atomic output waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Hygiene cleaning wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_hygiene_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Hygiene cleaning wastewater physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Remove polypropylene cleaning-wipe waste (hygiene_wipe_waste)

Polypropylene cleaning-wipe waste is recorded as one atomic output waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Polypropylene cleaning-wipe waste
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_hygiene_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Polypropylene cleaning-wipe waste physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Elementary flows

No atomic exchange is declared in this group for the current PCR.

Process: Onsite heat generation (onsite_heat_generation)

Inputs

Product flows
Supply grid electricity to onsite heat generation (heat_grid_electricity)

Grid electricity, medium voltage is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Grid electricity, medium voltage
  • Flow property / unit: Energy / kWh
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_heat_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Grid electricity, medium voltage physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Supply boiler feedwater (boiler_feedwater)

Boiler feedwater is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Boiler feedwater
  • Flow property / unit: Volume / m3
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_heat_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Boiler feedwater physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Supply natural gas (heat_natural_gas)

Natural gas is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Natural gas
  • Flow property / unit: Energy / MJ
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_heat_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Natural gas physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Supply diesel fuel (heat_diesel)

Diesel fuel is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Diesel fuel
  • Flow property / unit: Energy / MJ
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_heat_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Diesel fuel physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Supply liquefied petroleum gas (heat_lpg)

Liquefied petroleum gas is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Liquefied petroleum gas
  • Flow property / unit: Energy / MJ
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_heat_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Liquefied petroleum gas physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Supply light fuel oil (heat_light_fuel_oil)

Light fuel oil is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Light fuel oil
  • Flow property / unit: Energy / MJ
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_heat_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Light fuel oil physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Waste flows

No atomic exchange is declared in this group for the current PCR.

Elementary flows

No atomic exchange is declared in this group for the current PCR.

Outputs

Product flows
Produce onsite steam (onsite_steam)

Onsite steam is recorded as one atomic output product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Onsite steam
  • Flow property / unit: Energy / MJ
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_heat_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Onsite steam physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Produce onsite hot water (onsite_hot_water)

Onsite hot water is recorded as one atomic output product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Onsite hot water
  • Flow property / unit: Energy / MJ
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_heat_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Onsite hot water physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Waste flows
Remove boiler blowdown wastewater (boiler_blowdown)

Boiler blowdown wastewater is recorded as one atomic output waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Boiler blowdown wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_heat_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Boiler blowdown wastewater physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Remove light fuel oil tank sludge (fuel_oil_tank_sludge)

Light fuel oil tank sludge is recorded as one atomic output waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Light fuel oil tank sludge
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_heat_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Light fuel oil tank sludge physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Elementary flows
Release fossil carbon dioxide (combustion_co2)

Carbon dioxide, fossil, to air is recorded as one atomic output elementary exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Carbon dioxide, fossil, to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate the batch-attributable amount from the foreground records defined by the linked protocol.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_heat_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Carbon dioxide, fossil, to air physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Release nitrogen oxides (combustion_nox)

Nitrogen oxides to air is recorded as one atomic output elementary exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Nitrogen oxides to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate the batch-attributable amount from the foreground records defined by the linked protocol.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_heat_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Nitrogen oxides to air physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Release sulfur oxides (combustion_sox)

Sulfur oxides to air is recorded as one atomic output elementary exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Sulfur oxides to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate the batch-attributable amount from the foreground records defined by the linked protocol.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_heat_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Sulfur oxides to air physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Release carbon monoxide (combustion_co)

Carbon monoxide to air is recorded as one atomic output elementary exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Carbon monoxide to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate the batch-attributable amount from the foreground records defined by the linked protocol.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_heat_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Carbon monoxide to air physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Release particulate matter below 10 µm (combustion_pm10)

Particulate matter below 10 µm to air is recorded as one atomic output elementary exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Particulate matter below 10 µm to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate the batch-attributable amount from the foreground records defined by the linked protocol.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_heat_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Particulate matter below 10 µm to air physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Release particulate matter below 2.5 µm (combustion_pm25)

Particulate matter below 2.5 µm to air is recorded as one atomic output elementary exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Particulate matter below 2.5 µm to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate the batch-attributable amount from the foreground records defined by the linked protocol.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_heat_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Particulate matter below 2.5 µm to air physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Release methane (combustion_ch4)

Methane to air is recorded as one atomic output elementary exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Methane to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate the batch-attributable amount from the foreground records defined by the linked protocol.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_heat_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Methane to air physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Release nitrous oxide (combustion_n2o)

Nitrous oxide to air is recorded as one atomic output elementary exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Nitrous oxide to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate the batch-attributable amount from the foreground records defined by the linked protocol.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_heat_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Nitrous oxide to air physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.

Process: Onsite wastewater treatment (onsite_wastewater_treatment)

Inputs

Product flows
Supply grid electricity to wastewater treatment (wwt_grid_electricity)

Grid electricity, medium voltage is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Grid electricity, medium voltage
  • Flow property / unit: Energy / kWh
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwt_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Grid electricity, medium voltage physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Supply sodium hydroxide to wastewater treatment (wwt_sodium_hydroxide)

Sodium hydroxide is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Sodium hydroxide
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwt_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Sodium hydroxide physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Supply sulfuric acid to wastewater treatment (wwt_sulfuric_acid)

Sulfuric acid is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Sulfuric acid
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwt_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Sulfuric acid physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Supply ferric chloride to wastewater treatment (wwt_ferric_chloride)

Ferric chloride is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Ferric chloride
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwt_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Ferric chloride physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Supply calcium hydroxide to wastewater treatment (wwt_calcium_hydroxide)

Calcium hydroxide is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Calcium hydroxide
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwt_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Calcium hydroxide physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Supply anionic polyacrylamide to wastewater treatment (wwt_polyacrylamide)

Anionic polyacrylamide is recorded as one atomic input product exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Anionic polyacrylamide
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwt_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Anionic polyacrylamide physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Waste flows
Treat wet grain cleaning wastewater (wwt_grain_washwater)

Wet grain cleaning wastewater is recorded as one atomic input waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Wet grain cleaning wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwt_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Wet grain cleaning wastewater physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Treat grain conditioning condensate (wwt_conditioning_condensate)

Grain conditioning condensate is recorded as one atomic input waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Grain conditioning condensate
  • Flow property / unit: Volume / m3
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwt_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Grain conditioning condensate physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Treat milling cooling wastewater (wwt_milling_cooling_water)

Milling cooling wastewater is recorded as one atomic input waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Milling cooling wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwt_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Milling cooling wastewater physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Treat pellet conditioning condensate (wwt_pellet_condensate)

Pellet conditioning condensate is recorded as one atomic input waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Pellet conditioning condensate
  • Flow property / unit: Volume / m3
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwt_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Pellet conditioning condensate physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Treat grain-dust scrubber wastewater (wwt_scrubber_water)

Grain-dust scrubber wastewater is recorded as one atomic input waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Grain-dust scrubber wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwt_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Grain-dust scrubber wastewater physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Treat hygiene cleaning wastewater (wwt_hygiene_water)

Hygiene cleaning wastewater is recorded as one atomic input waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Hygiene cleaning wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwt_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Hygiene cleaning wastewater physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Treat boiler blowdown wastewater (wwt_boiler_blowdown)

Boiler blowdown wastewater is recorded as one atomic input waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Boiler blowdown wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwt_inputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Boiler blowdown wastewater physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Elementary flows

No atomic exchange is declared in this group for the current PCR.

Outputs

Product flows

No atomic exchange is declared in this group for the current PCR.

Waste flows
Transfer treated cereal-mill wastewater (treated_wastewater)

Treated cereal-mill wastewater is recorded as one atomic output waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Treated cereal-mill wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwt_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Treated cereal-mill wastewater physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Remove cereal-mill wastewater-treatment sludge (wwt_sludge)

Cereal-mill wastewater-treatment sludge is recorded as one atomic output waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Cereal-mill wastewater-treatment sludge
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwt_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Cereal-mill wastewater-treatment sludge physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Remove cereal-mill wastewater-treatment grit (wwt_grit)

Cereal-mill wastewater-treatment grit is recorded as one atomic output waste exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Cereal-mill wastewater-treatment grit
  • Flow property / unit: Mass / kg
  • Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwt_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Cereal-mill wastewater-treatment grit physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Elementary flows
Release biochemical oxygen demand (wwt_bod5)

Biochemical oxygen demand to water is recorded as one atomic output elementary exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Biochemical oxygen demand to water
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate the batch-attributable amount from the foreground records defined by the linked protocol.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_wwt_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Biochemical oxygen demand to water physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Release chemical oxygen demand (wwt_cod)

Chemical oxygen demand to water is recorded as one atomic output elementary exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Chemical oxygen demand to water
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate the batch-attributable amount from the foreground records defined by the linked protocol.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_wwt_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Chemical oxygen demand to water physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Release total suspended solids (wwt_tss)

Total suspended solids to water is recorded as one atomic output elementary exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Total suspended solids to water
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate the batch-attributable amount from the foreground records defined by the linked protocol.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_wwt_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Total suspended solids to water physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Release total nitrogen (wwt_total_n)

Total nitrogen to water is recorded as one atomic output elementary exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Total nitrogen to water
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate the batch-attributable amount from the foreground records defined by the linked protocol.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_wwt_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Total nitrogen to water physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Release total phosphorus (wwt_total_p)

Total phosphorus to water is recorded as one atomic output elementary exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Total phosphorus to water
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate the batch-attributable amount from the foreground records defined by the linked protocol.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_wwt_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Total phosphorus to water physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Release oil content (wwt_oil_grease)

Oil content to water is recorded as one atomic output elementary exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Oil content to water
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate the batch-attributable amount from the foreground records defined by the linked protocol.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_wwt_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Oil content to water physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Release methane from wastewater treatment (wwt_methane)

Methane to air is recorded as one atomic output elementary exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Methane to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate the batch-attributable amount from the foreground records defined by the linked protocol.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_wwt_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Methane to air physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.
Release nitrous oxide from wastewater treatment (wwt_n2o)

Nitrous oxide to air is recorded as one atomic output elementary exchange in this process; it does not represent any other grain, material, carrier, waste, pollutant, or emission.

  • Selected flow: Nitrous oxide to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate the batch-attributable amount from the foreground records defined by the linked protocol.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming reference product at the manufacturing facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_wwt_outputs
  • Sources: ec-jrc-fdm-bref-2019, eu-fdm-bat-2019-2031, eu-pef-2021-2279
  • UUID status: Unresolved; blank pending exact flow-hybrid-search and public state-100 direct-read confirmation.
  • Applicability: Record only when Nitrous oxide to air physically crosses this process boundary for the locked cereal species, product form, and actual route; otherwise mark this atomic row not applicable.
  • Uncertainty: Retain instrument resolution, calibration status, sampling basis, temporal coverage, and the batch reconciliation difference.

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page

Process: Dust collection and control (dust_collection_control)InputsProduct flowsSupply grid electricity to dust control (dust_control_grid_electricity)Supply compressed air to fabric-filter cleaning (dust_control_compressed_air)Supply polyester needle-felt filter fabric (dust_control_filter_fabric)Supply process water to wet scrubber (dust_control_scrubber_water)Waste flowsElementary flowsOutputsProduct flowsWaste flowsRemove captured common wheat dust (captured_dust_common_wheat)Remove captured durum wheat dust (captured_dust_durum_wheat)Remove captured rye dust (captured_dust_rye)Remove captured barley dust (captured_dust_barley)Remove captured oats dust (captured_dust_oats)Remove captured maize dust (captured_dust_maize)Remove captured sorghum dust (captured_dust_sorghum)Remove captured pearl millet dust (captured_dust_pearl_millet)Remove spent polyester filter fabric (spent_filter_fabric)Remove grain-dust scrubber wastewater (scrubber_wastewater)Elementary flowsRelease residual particulate matter below 10 µm (controlled_pm10)Release residual particulate matter below 2.5 µm (controlled_pm25)Process: Hygiene and equipment cleaning (hygiene_cleaning)InputsProduct flowsSupply grid electricity to hygiene cleaning (hygiene_grid_electricity)Supply compressed air to dry cleaning (hygiene_compressed_air)Supply process water to hygiene cleaning (hygiene_process_water)Supply purchased hot water to hygiene cleaning (hygiene_purchased_hot_water)Supply purchased steam to hygiene cleaning (hygiene_purchased_steam)Supply sodium hydroxide (hygiene_sodium_hydroxide)Supply nitric acid (hygiene_nitric_acid)Supply phosphoric acid (hygiene_phosphoric_acid)Supply peracetic acid (hygiene_peracetic_acid)Supply sodium hypochlorite (hygiene_sodium_hypochlorite)Waste flowsElementary flowsOutputsProduct flowsWaste flowsRemove common wheat dry sweepings (dry_sweepings_common_wheat)Remove durum wheat dry sweepings (dry_sweepings_durum_wheat)Remove rye dry sweepings (dry_sweepings_rye)Remove barley dry sweepings (dry_sweepings_barley)Remove oats dry sweepings (dry_sweepings_oats)Remove maize dry sweepings (dry_sweepings_maize)Remove sorghum dry sweepings (dry_sweepings_sorghum)Remove pearl millet dry sweepings (dry_sweepings_pearl_millet)Remove hygiene cleaning wastewater (hygiene_wastewater)Remove polypropylene cleaning-wipe waste (hygiene_wipe_waste)Elementary flowsProcess: Onsite heat generation (onsite_heat_generation)InputsProduct flowsSupply grid electricity to onsite heat generation (heat_grid_electricity)Supply boiler feedwater (boiler_feedwater)Supply natural gas (heat_natural_gas)Supply diesel fuel (heat_diesel)Supply liquefied petroleum gas (heat_lpg)Supply light fuel oil (heat_light_fuel_oil)Waste flowsElementary flowsOutputsProduct flowsProduce onsite steam (onsite_steam)Produce onsite hot water (onsite_hot_water)Waste flowsRemove boiler blowdown wastewater (boiler_blowdown)Remove light fuel oil tank sludge (fuel_oil_tank_sludge)Elementary flowsRelease fossil carbon dioxide (combustion_co2)Release nitrogen oxides (combustion_nox)Release sulfur oxides (combustion_sox)Release carbon monoxide (combustion_co)Release particulate matter below 10 µm (combustion_pm10)Release particulate matter below 2.5 µm (combustion_pm25)Release methane (combustion_ch4)Release nitrous oxide (combustion_n2o)Process: Onsite wastewater treatment (onsite_wastewater_treatment)InputsProduct flowsSupply grid electricity to wastewater treatment (wwt_grid_electricity)Supply sodium hydroxide to wastewater treatment (wwt_sodium_hydroxide)Supply sulfuric acid to wastewater treatment (wwt_sulfuric_acid)Supply ferric chloride to wastewater treatment (wwt_ferric_chloride)Supply calcium hydroxide to wastewater treatment (wwt_calcium_hydroxide)Supply anionic polyacrylamide to wastewater treatment (wwt_polyacrylamide)Waste flowsTreat wet grain cleaning wastewater (wwt_grain_washwater)Treat grain conditioning condensate (wwt_conditioning_condensate)Treat milling cooling wastewater (wwt_milling_cooling_water)Treat pellet conditioning condensate (wwt_pellet_condensate)Treat grain-dust scrubber wastewater (wwt_scrubber_water)Treat hygiene cleaning wastewater (wwt_hygiene_water)Treat boiler blowdown wastewater (wwt_boiler_blowdown)Elementary flowsOutputsProduct flowsWaste flowsTransfer treated cereal-mill wastewater (treated_wastewater)Remove cereal-mill wastewater-treatment sludge (wwt_sludge)Remove cereal-mill wastewater-treatment grit (wwt_grit)Elementary flowsRelease biochemical oxygen demand (wwt_bod5)Release chemical oxygen demand (wwt_cod)Release total suspended solids (wwt_tss)Release total nitrogen (wwt_total_n)Release total phosphorus (wwt_total_p)Release oil content (wwt_oil_grease)Release methane from wastewater treatment (wwt_methane)Release nitrous oxide from wastewater treatment (wwt_n2o)