TianGong PCR产品类别规则

Parts of electricity distribution or control apparatus

Parts of electricity distribution or control apparatus: This PCR covers factory-gate production of discrete parts designed solely or principally for electricity…

Lifecycle status
Candidate
Content maturity
Authored methodology
Current version
No published version
Readiness
Review required
Last updated

Methodology and translation states come from the source record; publishing this website does not change their review status.

Content languages

zh-CN · Aligned
Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:46220 · exact

Source

1. Scope and Applicability

This PCR covers factory-gate production of discrete parts designed solely or principally for electricity distribution or control apparatus. Covered examples include conductive connections and contacts, busbar links, terminals, mechanical operating parts, dedicated housings, mounting pieces, and insulating supports supplied as parts rather than complete apparatus.

The foreground boundary begins with production-ready purchased inputs at the factory gate and ends with a conforming finished part ready for dispatch. It includes applicable forming, moulding, machining, joining, assembly, inspection and testing, aqueous surface treatment, coating preparation, and on-site thermal energy. Upstream production of purchased inputs must be represented by linked datasets.

Complete apparatus, equipped boards or cabinets, optical-fibre connectors, general-purpose fasteners, buildings, capital equipment, installation, use, distribution after the factory gate, and end of life are excluded. Packaging is outside the reference-product mass; when included in study scope, each actual packaging component must be added as a separate atomic exchange.

Because CPC 46220 spans materially different parts, each dataset must represent one declared part or homogeneous family. Unlike functions, materials, voltage classes, or routes must not be averaged without disclosure and production-weighted aggregation.

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.metal-products-machinery-and-equipment.electrical-machinery-and-apparatus.parts-of-electricity-distribution-or-control-apparatus
classification_refsCPC 3.0: 46220, Parts of electricity distribution or control apparatus
covered_productsDiscrete conductive, mechanical, enclosure, mounting and insulating parts designed solely or principally for electricity distribution or control apparatus and supplied as parts
excluded_productsComplete apparatus in CPC 4621; equipped boards, consoles or cabinets; optical-fibre connectors; generic fasteners; transformers and transformer parts; cables; buildings; capital equipment; installation, use and end-of-life services
representative_productA conforming, production-ready connection, contact, terminal, busbar link, mechanism, housing, mounting piece or insulating support supplied as a part
production_routePurchased production-ready inputs; forming, moulding or machining; optional surface treatment or oxygen-assisted cutting; joining or assembly; inspection and testing; factory-gate release
market_stateFinished part at factory gate, with specification revision, function, material grade, voltage class where relevant, surface or insulation specification, mass, route and geography declared

3. Reference Flow

FieldValue
WhatProvision of a conforming part designed solely or principally for electricity distribution or control apparatus
How much1 kg net mass of finished conforming part, excluding packaging
How wellMeets the declared drawing, material grade, tolerances, function, voltage class where relevant, and surface-finish or insulation specification
How long or cycleOne production lot released at the factory gate; no use-stage service life is credited
reference_flow_linkExactly 1 kg of the declared reference product flow realizes the functional unit
FieldValue
Reference amount1 kg
Reference product flowParts of electricity distribution or control apparatus a7efcaee-e37f-42ab-8b39-2ae4d572bb2b
Reference flow propertyMass 93a60a56-a3c8-11da-a746-0800200b9a66
Reference unit groupUnits of mass 93a60a57-a4c8-11da-a746-0800200c9a66
Reference unitkg
Required qualifierspart number or homogeneous family; drawing or specification revision; part function; material grade and purchased form; net part mass; voltage class where relevant; surface or insulation specification; manufacturing route, technology, geography and reporting period; recycled-content claim if used; packaging exclusion; rejects and scrap treatment

When constructing a foreground data package, the items listed in Required qualifiers must be declared in dataset metadata, process notes, reference flow comment, product description, or an equivalent data package field. Missing required qualifiers make the reference flow definition incomplete for that data package.

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
reference_massreference product and mass-based rowsMass 93a60a56-a3c8-11da-a746-0800200b9a66kgNormalize inventory to 1 kg net mass of accepted finished parts. Use dry or as-received mass consistently as declared; exclude packaging and rejects from the denominator.
electricity_conversionpurchased electricityNet calorific value 93a60a56-a3c8-11da-a746-0800200b9a66MJPreserve the meter basis and convert kWh to MJ with 1 kWh = 3.6 MJ. Do not include upstream grid emissions as direct elementary flows.
gas_volume_basisgaseous natural gas and industrial oxygenVolume 93a60a56-a3c8-22da-a746-0800200c9a66m3Report metered volume at declared temperature and pressure; retain any normal- or standard-cubic-metre reference condition and conversion.
water_mass_basisprocess water and aqueous wastewaterMass 93a60a56-a3c8-11da-a746-0800200b9a66kgPrefer mass metering. Convert volume only with recorded volume, density assumption, temperature and formula.

5. System Boundary

Boundary Abstraction

FieldValue
declared_starting_conditionProduction-ready purchased materials, components, chemicals and energy carriers received at the foreground factory gate
starting_condition_roleForeground manufacturing starts at receipt; extraction, refining and manufacture of purchased inputs are represented by upstream datasets
product_classification_scopeDedicated parts supplied separately for electricity distribution or control apparatus; complete apparatus and general-purpose items are excluded
recursive_input_ruleA purchased CPC 46220 input is recorded once with its upstream dataset and is not recursively remanufactured inside this foreground boundary
upstream_dataset_requirementEach purchased product or energy input links to a geographically and technologically representative dataset with declared state and delivery boundary
disclosureDeclare product definition, composition, purchased forms, included and subcontracted operations, geography, period, energy supply, scrap destinations, wastewater and sludge hand-off, and omissions
rule_idApplies toRulesource_ids
boundary_factory_gateforeground manufacturingInclude all on-site operations from receipt through release of the conforming part; exclude distribution, installation, use, maintenance and end of life.schneider-electric-masterpact-rear-connection-pep-2024
boundary_surface_treatmentaqueous surface treatmentInclude water, each chemical, electricity and heat, bath losses, wastewater, sludge, and directly measured emissions when aqueous treatment applies; otherwise document each row as not applicable.eu-jrc-stm-bref-2006
boundary_actual_materialspurchased inputsAdd one atomic product-input row for every actual purchased material or component; never substitute an umbrella material-family row.schneider-electric-masterpact-rear-connection-pep-2024

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
part_manufacturingPart manufacturing, finishing and releaserequiredAlways included; route-conditional exchanges are identified on their atomic cardsForeground forming, moulding, machining, optional treatment, joining, assembly, inspection and testing1 kg net mass of conforming finished part at factory gate

Process: Part manufacturing, finishing and release (part_manufacturing)

Inputs

Product flows
Refined copper stock (refined_copper_input)

Record refined copper only when consumed in the declared part; declare grade, alloy, form, recycled content and supplier boundary.

  • Selected flow: Refined copper 176d7abf-4f6c-4584-a720-f9a518ce7d2d
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 / kg
  • Amount rule: accepted copper stock issued to the lot minus documented unopened returns
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg net mass of conforming finished part
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material_mass
  • Sources: schneider-electric-masterpact-rear-connection-pep-2024
Cold-rolled steel sheet (steel_sheet_input)

Record this row only for a steel-sheet route. Its UUID remains unresolved after bounded state-100 review.

  • Selected flow: Cold-rolled steel sheet
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 / kg
  • Amount rule: accepted cold-rolled steel sheet issued to the lot minus documented unopened returns
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg net mass of conforming finished part
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material_mass
  • Sources: schneider-electric-masterpact-rear-connection-pep-2024
Purchased electricity (manufacturing_electricity_input)

Record electricity delivered to all included production and allocated site-support equipment. Exclude upstream generation emissions from direct outputs.

  • Selected flow: Electricity 890a70b7-b677-4e2a-8a1b-7d017e0a10ae
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200b9a66 / Units of energy 93a60a57-a3c8-11da-a746-0800200c9a66 / MJ
  • Amount rule: metered or production-accounted purchased electricity attributable to the lot
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net mass of conforming finished part
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_energy_records
  • Sources:
Process water (process_water_input)

Record process water for applicable cleaning, rinsing, surface treatment or testing; declare quality, source and delivery boundary.

  • Selected flow: Process Water 94a04f7e-2d5c-41f0-b182-d54a3b373a02
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 / kg
  • Amount rule: metered or tank-balance process water; not applicable when no water-using operation is included
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net mass of conforming finished part
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_water_chemical_records
  • Sources: eu-jrc-stm-bref-2006
Sodium hydroxide (sodium_hydroxide_input)

Record sodium hydroxide only when consumed by the declared cleaning or treatment bath; retain supplied state and concentration.

  • Selected flow: Sodium hydroxide e0abcced-0611-4c24-9290-5a2c5a0c4169
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 / kg
  • Amount rule: active sodium-hydroxide mass charged or replenished; not applicable when absent from the chemistry
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net mass of conforming finished part
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_water_chemical_records
  • Sources: eu-jrc-stm-bref-2006
Industrial oxygen (industrial_oxygen_input)

Record supplied oxygen only for an applicable oxygen-assisted operation; declare purity, pressure and volume reference conditions.

  • Selected flow: Industrial oxygen bd4b0f96-2090-4806-a648-335ab20ff401
  • Flow property / unit: Volume 93a60a56-a3c8-22da-a746-0800200c9a66 / Units of volume 93a60a57-a3c8-12da-a746-0800200c9a66 / m3
  • Amount rule: metered or cylinder-inventory oxygen consumed; not applicable when oxygen-assisted processing is absent
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net mass of conforming finished part
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_energy_records
  • Sources:
Gaseous natural gas (natural_gas_input)

Record natural gas only when on-site combustion supplies attributable process heat; declare composition, supply geography and reference conditions.

  • Selected flow: natural gas in the gaseous state 4f19ca0e-7b3b-11dd-ad8b-0800200c9a66
  • Flow property / unit: Volume 93a60a56-a3c8-22da-a746-0800200c9a66 / Units of volume 93a60a57-a3c8-12da-a746-0800200c9a66 / m3
  • Amount rule: metered or invoice-balanced natural gas; not applicable when natural gas is absent
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net mass of conforming finished part
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_energy_records
  • Sources:
Waste flows
Elementary flows

Outputs

Product flows
Conforming finished part (reference_product_output)

Record only accepted finished-part mass; exclude rejected parts, packaging and dispatch accessories.

  • Selected flow: Parts of electricity distribution or control apparatus a7efcaee-e37f-42ab-8b39-2ae4d572bb2b
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 / kg
  • Amount rule: fixed reference output of 1 kg net mass of conforming finished part
  • Value mode: Fixed value (fixed_value)
  • Specificity: Generic (generic)
  • Normalization basis: 1 kg reference product output
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Identity reference (identity_reference)
  • Collection protocol:
  • Sources:
Waste flows
Post-industrial steel scrap (steel_scrap_output)

Record segregated steel offcuts, punchings and rejected pieces leaving as waste; do not net scrap against material input.

  • Selected flow: Post-industrial steel scrap c143745d-be4f-4d8f-b403-2dcbfe685349
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 / kg
  • Amount rule: measured steel scrap dispatched or accumulated; not applicable when no steel is processed
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg net mass of conforming finished part
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_output_mass
  • Sources:
Copper scrap (copper_scrap_output)

Record segregated copper offcuts, punchings, turnings and rejected pieces; declare sorting, contamination and destination.

  • Selected flow: Copper Scrap 4fbbb5f1-560a-4052-ba0c-652c5dfc282e
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 / kg
  • Amount rule: measured copper scrap dispatched or accumulated; not applicable when no copper is processed
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg net mass of conforming finished part
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_output_mass
  • Sources:
Surface-treatment wastewater (surface_treatment_wastewater_output)

Record aqueous wastewater from rinsing, bath dumps and cleaning; declare composition, water basis and treatment hand-off. Its UUID remains unresolved.

  • Selected flow: Wastewater from metal surface treatment
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 / kg
  • Amount rule: metered or tank-balance wastewater leaving the foreground boundary; not applicable when none is generated
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net mass of conforming finished part
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_output_mass
  • Sources: eu-jrc-stm-bref-2006
Metal-bearing surface-treatment sludge (surface_treatment_sludge_output)

Record bath-maintenance or wastewater-treatment sludge; declare wet or dry basis, metals, hazardous classification and destination. Its UUID remains unresolved.

  • Selected flow: Metal-bearing surface-treatment sludge
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 / kg
  • Amount rule: measured sludge leaving the boundary on the declared basis; not applicable when none is generated
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net mass of conforming finished part
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_output_mass
  • Sources: eu-jrc-stm-bref-2006
Elementary flows
Direct fossil carbon dioxide (fossil_carbon_dioxide_output)

Record only fossil CO2 emitted directly from foreground combustion; exclude upstream electricity, fuel-supply and material emissions.

  • Selected flow: carbon dioxide (fossil) 08a91e70-3ddc-11dd-923d-0050c2490048
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 / kg
  • Amount rule: measured or fuel-balance-calculated direct fossil CO2; not applicable when no fossil fuel is combusted
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net mass of conforming finished part
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_direct_emission
  • Sources:

7. Allocation and Co-product Handling

rule_idApplies toRulesource_ids
allocation_avoidshared lines and servicesFirst avoid allocation through lot-, line- or equipment-level metering and subdivision.
allocation_physicalunavoidable shared exchangesAllocate using a documented causal physical driver such as machine time, metered energy, processed mass, bath loading or occupied volume; do not default to revenue.
allocation_scraprecoverable scrapReport gross inputs and gross scrap outputs without netting. Declare the end-of-waste boundary and recycling method; do not credit avoided production inside this foreground inventory unless explicitly required by goal and scope.
allocation_qualityfamily datasetsAllow production-weighted family averages only for sufficiently homogeneous functions, specifications, materials and routes; otherwise publish separate datasets.

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_material_masspart_manufacturingpurchased material inputERP issues, returns and weigh ticketsidentity; grade; form; supplier; lot; issued and returned mass; recycled contentreconcile ERP movements, lot travellers and calibrated scaleskgeach lot; monthly reconciliationat least 12 representative months or full shorter campaignall included lines and subcontracted additionsissued mass minus documented unopened returns; normalize by accepted outputspecification; supplier declaration; traveller; calibration; reconciliation
cp_energy_recordspart_manufacturingelectricity and gas inputmeter, invoice, cylinder or tank inventorycarrier; readings; quantity; reference conditions; allocation driverdedicated meters where available; otherwise reconcile commercial or inventory recordsMJ; m3meter or delivery interval; monthly reconciliationproduction reporting periodincluded operations and allocated supportremove unrelated loads; allocate with declared driver; normalize by outputcalibration; invoice; inventory reconciliation; allocation worksheet
cp_water_chemical_recordspart_manufacturingwater and chemical inputmeter, tank balance, batch sheet, concentration certificatewater quantity; density; solution mass; active concentration; bath charge and replenishmentreconcile meters and batches; calculate active chemical masskgeach charge or meter interval; monthly reconciliationproduction reporting periodeach included aqueous linesum attributable input; convert volume with documented density; normalize by outputcalibration; certificate; batch sheet; tank reconciliation
cp_output_masspart_manufacturingproduct and waste outputinspection release, scale, manifest, tank recordproduct mass; waste identity; wet or dry basis; composition; destination; dispatch massweigh accepted product and segregated wastes; reconcile tanks and manifestskgeach lot or dispatch; monthly reconciliationproduction reporting periodall included operations and hand-off pointssum atomic outputs separately; normalize by output; no scrap nettingrelease; calibration; manifest; analysis; mass balance
cp_direct_emissionpart_manufacturingdirect fossil CO2stack or fuel recordemission; fuel; carbon content; fossil fraction; oxidation basis; drivercompliant measurement or disclosed calculation from collected fuel datakgtest or accounting interval; monthly reconciliationproduction reporting periodincluded combustion sourcessum attributable direct fossil CO2; normalize by outputstack report or fuel certificate; worksheet; fuel balance

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
calc_reference_normalizationevery inventory rownormalized amount = attributable exchange / net accepted finished-part massexchange quantity; accepted output massamount per 1 kg reference product
calc_electricitypurchased electricityMJ = metered kWh × 3.6kWhMJ electricity
calc_active_naohsodium-hydroxide solutionactive NaOH mass = solution mass × certified mass fractionsolution mass; fractionkg active sodium hydroxide
calc_water_masswater measured by volumewater mass = volume × documented density at declared temperaturevolume; density; temperaturekg water or wastewater
calc_direct_fossil_co2on-site combustionUse direct measurement or a disclosed calculation from collected fuel quantity, carbon content, fossil fraction and oxidation basisstack or fuel recordskg direct fossil CO2

Data Quality Requirements

requirement_idApplies toRequirementEvidence
dq_identityproduct and materialsRetain family rule, drawing revision, function, voltage class where relevant, grade, purchased form and surface or insulation specification.specification; drawing; bill of materials; supplier certificate
dq_timeforeground recordsUse one representative reporting period; justify abnormal batches and periods shorter than 12 months.calendar; monthly reconciliation; exception log
dq_measurementquantitiesUse calibrated instruments or reconciled commercial records; retain units, reference conditions, conversions and allocation drivers.calibration; invoices; meter extracts; workbook
dq_completenessinventoryReconcile accepted output, major inputs and wastes; document exclusions and each not-applicable conditional row.mass balance; manifests; route checklist
dq_geography_technologyupstream and foreground dataMatch declared material state, geography, energy supply and technology or explain substitutions.dataset metadata; supplier geography; justification
dq_uncertaintyrows without rangesPreserve foreground evidence and do not invent benchmark ranges; retain unresolved two-source range needs for review.unresolved range-evidence register; review record

9. Validation Rules

rule_idApplies toRulesource_ids
validate_referencereference flowConfirm one 1 kg CPC 46220 reference output and all required qualifiers.un-cpc-3-0-structure-2025
validate_atomic_rowsinventoryConfirm every selected flow is one atomic exchange; reject umbrella material, energy, utility, packaging, waste or emission rows.
validate_applicabilityconditional exchangesRequire a collected value or documented not-applicable determination tied to the route.eu-jrc-stm-bref-2006
validate_mass_balanceforeground manufacturingCheck accepted output plus wastes against mass inputs on consistent bases; investigate differences.
validate_energy_boundaryelectricity and fuelsKeep purchased electricity and on-site fuel separate; report only foreground direct combustion emissions as elementary outputs.
validate_uuid_semanticsUUID rowsReconfirm state-100 identity, names, flow type, classification, property, unit group, state and general comment.
validate_unresolvedUUID and range gapsKeep gaps visible; never substitute proxy UUIDs or invented ranges.

10. Published Dataset Profile

FieldValue
dataset_rolesecondary_dataset or background_dataset after review and publication
downstream_useCradle-to-gate input for a specified electricity distribution or control apparatus, assembly, process or lifecycle model
allowed_useDeclared part or homogeneous family, site and period while qualifiers, route, composition, allocation, upstream links and quality remain representative
excluded_useComplete apparatus; dissimilar families; undisclosed function or voltage change; installation, use or end-of-life claims; unweighted cross-site or cross-route averages
required_metadataPCR id; CPC ref; product definition; revision; function; voltage; materials; net mass; surface or insulation specification; route; site; geography; period; energy; allocation; waste destinations; unresolved items
required_quality_disclosureforeground share; coverage; measurement quality; bill-of-materials completeness; upstream substitutions; allocation; mass balance; not-applicable rows; subcontracting; uncertainty
update_triggermaterial, drawing, function, voltage, finish, insulation, route, supplier, site, energy, allocation or period change that materially alters inventory; UUID or range resolution

11. Data Sources

Source idTypeReferenceUsed for
un-cpc-3-0-structure-2025Official guidance (official_guidance)United Nations Statistics Division, CPC Version 3.0 Structure, 30 June 2025, https://unstats.un.org/unsd/classifications/Econ/Download/In%20Text/CPC_Ver_3.0_Structure_30Jun2025.csv (retrieved 2026-09-04)Classification identity and separation of parts in 4622/46220 from complete apparatus in 4621
schneider-electric-masterpact-rear-connection-pep-2024Dataset (dataset)Schneider Electric, PEP ecopassport SCHN-01170-V01.01-EN: Rear horizontal connection, MasterPact MTZ2 fixed/drawout, 3P, top connection, 2500A-3200A, September 2024, https://download.se.com/files?p_Doc_Ref=ENVPEP2404003EN&p_File_Name=PEP+ecopassport+SCHN-01170-V01.01-EN.pdf&p_enDocType=Environmental+Disclosure (retrieved 2026-09-04)Separate connection-part identity, copper and steel constituents, and manufacturing-stage separation
eu-jrc-stm-bref-2006Official guidance (official_guidance)European Commission Joint Research Centre, Surface Treatment of Metals and Plastics BREF, adopted August 2006, https://bureau-industrial-transformation.jrc.ec.europa.eu/reference/surface-treatment-metals-and-plastics (retrieved 2026-09-04)Conditional electrolytic or chemical treatment boundary, water-based operations and associated activities

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 3
Rule IDApplies toRuleSource IDs
boundary_factory_gateforeground manufacturingInclude all on-site operations from receipt through release of the conforming part; exclude distribution, installation, use, maintenance and end of life.schneider-electric-masterpact-rear-connection-pep-2024
boundary_surface_treatmentaqueous surface treatmentInclude water, each chemical, electricity and heat, bath losses, wastewater, sludge, and directly measured emissions when aqueous treatment applies; otherwise document each row as not applicable.eu-jrc-stm-bref-2006
boundary_actual_materialspurchased inputsAdd one atomic product-input row for every actual purchased material or component; never substitute an umbrella material-family row.schneider-electric-masterpact-rear-connection-pep-2024
Allocation rules · 4
Rule IDApplies toRuleSource IDs
allocation_avoidshared lines and servicesFirst avoid allocation through lot-, line- or equipment-level metering and subdivision.
allocation_physicalunavoidable shared exchangesAllocate using a documented causal physical driver such as machine time, metered energy, processed mass, bath loading or occupied volume; do not default to revenue.
allocation_scraprecoverable scrapReport gross inputs and gross scrap outputs without netting. Declare the end-of-waste boundary and recycling method; do not credit avoided production inside this foreground inventory unless explicitly required by goal and scope.
allocation_qualityfamily datasetsAllow production-weighted family averages only for sufficiently homogeneous functions, specifications, materials and routes; otherwise publish separate datasets.
Validation rules · 7
Rule IDApplies toRuleSource IDs
validate_referencereference flowConfirm one 1 kg CPC 46220 reference output and all required qualifiers.un-cpc-3-0-structure-2025
validate_atomic_rowsinventoryConfirm every selected flow is one atomic exchange; reject umbrella material, energy, utility, packaging, waste or emission rows.
validate_applicabilityconditional exchangesRequire a collected value or documented not-applicable determination tied to the route.eu-jrc-stm-bref-2006
validate_mass_balanceforeground manufacturingCheck accepted output plus wastes against mass inputs on consistent bases; investigate differences.
validate_energy_boundaryelectricity and fuelsKeep purchased electricity and on-site fuel separate; report only foreground direct combustion emissions as elementary outputs.
validate_uuid_semanticsUUID rowsReconfirm state-100 identity, names, flow type, classification, property, unit group, state and general comment.
validate_unresolvedUUID and range gapsKeep gaps visible; never substitute proxy UUIDs or invented ranges.
Processes and inputs/outputs · 1
Process IDProcess nameInput flowsOutput flows
part_manufacturingPart manufacturing, finishing and release76

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page