1. Scope and Applicability

This PCR covers factory production of physical parts designed principally for electrical transformers, static converters, or inductors: magnetic cores, windings and coil subassemblies, dedicated insulation and terminals, converter-specific busbars and populated boards, housings, cooling parts, and dedicated subassemblies. Finished apparatus, generic upstream materials or components, manufacturing services, installation, maintenance, use losses, and end-of-life are excluded. Declare the concrete part family and include only route operations and atomic exchanges that apply.

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.metal-products-machinery-and-equipment.electrical-machinery-and-apparatus.parts-of-electrical-transformers-static-converters-and-inductors
classification_refsCPC 3.0: 46132, Parts of electrical transformers, static converters and inductors
covered_productsDedicated cores, windings, coil subassemblies, converter busbars, power modules, populated boards, enclosures, terminals, insulation and cooling parts
excluded_productsComplete transformers, ballasts, static converters or inductors; generic materials and electronic components; distribution/control apparatus; services
representative_productOne declared market-ready part or homogeneous lot within CPC 46132
production_routeRoute-qualified core forming, winding, metalworking, board assembly, molding, surface treatment, testing and packing
market_stateConforming, dry, saleable part at factory gate, with shipment packaging where applied; not installed in complete apparatus

3. Reference Flow

FieldValue
WhatProduction and provision of a conforming market-ready part for an electrical transformer, static converter, or inductor
How much1 kg net conforming product, excluding removable shipment packaging
How wellMeets declared drawing, part number, material/insulation specification, acceptance criteria, and quality plan
How long or cycleOne production lot at factory gate; no use-stage duration
reference_flow_linkOutput row reference_product_output, normalized to 1 kg
FieldValue
Reference amount1 kg
Reference product flowParts of electrical transformers, static converters and inductors d4ea4c05-fc8a-4f2b-b6e9-0ecae8795a95
Reference flow propertyMass 93a60a56-a3c8-11da-a746-0800200b9a66
Reference unit groupUnits of mass 93a60a57-a4c8-11da-a746-0800200c9a66
Reference unitkg
Required qualifierspart family/number; recipient apparatus; conductor/core material; insulation system; board population state; route; treatment; site; period; packaging; net-mass basis

Required qualifiers must appear in the foreground data package; otherwise its reference flow is incomplete.

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
reference_product_massreference product and mass rowsMass 93a60a56-a3c8-11da-a746-0800200b9a66kgUse dry net mass; exclude removable shipment packaging and report it separately.
electricity_energyelectricity_inputNet calorific value 93a60a56-a3c8-11da-a746-0800200b9a66MJPreserve meter records and convert kWh using 1 kWh = 3.6 MJ; disclose grid, voltage, and included losses.
gas_volumenatural_gas_inputVolume 93a60a56-a3c8-22da-a746-0800200c9a66m3Declare temperature, pressure, moisture, and standard/actual conditions.
industrial_gas_volumeindustrial_oxygen_inputVolume 93a60a56-a3c8-22da-a746-0800200c9a66m3Declare purity and reference conditions.

5. System Boundary

Boundary Abstraction

FieldValue
declared_starting_conditionPurchased materials, components, chemicals, utilities and packaging received at the manufacturing site
starting_condition_roleForeground gate-to-gate start linked to upstream supply and inbound-transport datasets
product_classification_scopePhysical CPC 46132 parts, independent of upstream input classifications
recursive_input_ruleRecord a purchased CPC 46132 input once and link its upstream dataset; do not recreate its production recursively
upstream_dataset_requirementLink every purchased product and energy input to geographically and technologically representative upstream data
disclosurePart family; recipient apparatus; BOM; materials; board state; route; treatment; site/period; yield; allocation; packaging; exclusions
rule_idApplies toRulesource_ids
boundary_rule_1foregroundInclude applicable forming, winding, board assembly, molding, joining, treatment, testing, rejects, utilities, direct emissions and packing through factory gate.oria-et-al-transformer-lca-review-2026; iea-pvps-lci-photovoltaic-systems-2020
boundary_rule_2upstream linkageUse linked upstream datasets for purchased inputs and inbound transport; never hide them in an aggregate input.iea-pvps-lci-photovoltaic-systems-2020
boundary_rule_3exclusionsExclude complete apparatus manufacture/use, losses, installation, distribution and end-of-life unless separately expanded and reported.eu-transformer-regulation-548-2014; oria-et-al-transformer-lca-review-2026

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
part_fabrication_assemblyRoute-qualified part fabrication, assembly, testing and packingrequiredInclude only operations and atomic exchanges for the declared part routeforeground production1 kg conforming reference product

Process: Route-qualified part fabrication, assembly, testing and packing (part_fabrication_assembly)

Inputs

Product flows
Electrical steel sheet for laminated cores (electrical_steel_input)

Only for laminated or wound steel cores; declare grade and coating.

  • Selected flow: Electrical steel sheet
  • Flow property / unit: Mass / kg
  • Amount rule: Measured net issued mass minus returns
  • Value mode: Foreground record (foreground_record)
  • Specificity: product specific (product_specific)
  • Normalization basis: per 1 kg conforming reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material_component_mass
  • Sources: oria-et-al-transformer-lca-review-2026
Insulated conductor for windings (magnet_wire_input)

Only for winding routes; declare copper or aluminium conductor, insulation chemistry, thermal class, and form.

  • Selected flow: Magnet wire 2bf8a4db-b29e-404a-ae6c-402adbb77af4
  • Flow property / unit: Mass / kg
  • Amount rule: Measured net issued magnet-wire mass minus returns
  • Value mode: Foreground record (foreground_record)
  • Specificity: product specific (product_specific)
  • Normalization basis: per 1 kg conforming reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material_component_mass
  • Sources: eu-transformer-regulation-548-2014; oria-et-al-transformer-lca-review-2026
Ferrite core for high-frequency magnetic parts (ferrite_core_input)

Only for ferrite-based parts; declare material family, geometry, and state.

  • Selected flow: Ferrite magnetic core
  • Flow property / unit: Mass / kg
  • Amount rule: Measured ferrite-core mass consumed
  • Value mode: Foreground record (foreground_record)
  • Specificity: product specific (product_specific)
  • Normalization basis: per 1 kg conforming reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material_component_mass
  • Sources: iea-pvps-lci-photovoltaic-systems-2020
Cellulose electrical insulation paper (electrical_insulation_paper_input)

Only when retained as insulation; declare grade, thickness, treatment, and moisture basis.

  • Selected flow: Cellulose electrical insulation paper
  • Flow property / unit: Mass / kg
  • Amount rule: Measured net issued dry mass minus returns
  • Value mode: Foreground record (foreground_record)
  • Specificity: product specific (product_specific)
  • Normalization basis: per 1 kg conforming reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material_component_mass
  • Sources: oria-et-al-transformer-lca-review-2026
Non-alloy steel for enclosure or hardware (non_alloy_steel_input)

Only when fabricated into the declared enclosure, bracket, terminal, or cooling part.

  • Selected flow: Non-Alloy Steel ce3ac926-5d6f-4558-9edc-67179d93dde4
  • Flow property / unit: Mass / kg
  • Amount rule: Measured net issued steel mass minus returns
  • Value mode: Foreground record (foreground_record)
  • Specificity: product specific (product_specific)
  • Normalization basis: per 1 kg conforming reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material_component_mass
  • Sources: oria-et-al-transformer-lca-review-2026; iea-pvps-lci-photovoltaic-systems-2020
Printed wire board for converter assembly (printed_wire_board_input)

Only when populated or integrated on site; declare area, layer count, substrate, and finish.

  • Selected flow: Printed Wire Board a8bd954c-59b3-4317-b4de-02a17d6da5ca
  • Flow property / unit: Mass / kg
  • Amount rule: Measured mass of boards issued
  • Value mode: Foreground record (foreground_record)
  • Specificity: product specific (product_specific)
  • Normalization basis: per 1 kg conforming reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material_component_mass
  • Sources: iea-pvps-lci-photovoltaic-systems-2020
Lead-free flux-free solder (lead_free_solder_input)

Only for flux-free lead-free joining; other solder states require separate rows.

  • Selected flow: Lead-free solder, flux-free a78ab927-44b9-4978-a3e3-2b9fb20d3648
  • Flow property / unit: Mass / kg
  • Amount rule: Measured net solder consumption
  • Value mode: Foreground record (foreground_record)
  • Specificity: technology specific (technology_specific)
  • Normalization basis: per 1 kg conforming reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material_component_mass
  • Sources: iea-pvps-lci-photovoltaic-systems-2020
Power semiconductor device (power_semiconductor_input)

Only for converter parts; declare one actual device family per data package.

  • Selected flow: Insulated-gate bipolar transistor power semiconductor device
  • Flow property / unit: Mass / kg
  • Amount rule: Measured mass of the declared device family
  • Value mode: Foreground record (foreground_record)
  • Specificity: product specific (product_specific)
  • Normalization basis: per 1 kg conforming reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material_component_mass
  • Sources: iea-pvps-lci-photovoltaic-systems-2020
Glass-fibre-reinforced polyamide granulate (glass_fibre_polyamide_input)

Only for on-site molding; declare polymer grade, fibre fraction, and recycled content.

  • Selected flow: Glass-fibre-reinforced polyamide granulate
  • Flow property / unit: Mass / kg
  • Amount rule: Measured dry granulate issued
  • Value mode: Foreground record (foreground_record)
  • Specificity: product specific (product_specific)
  • Normalization basis: per 1 kg conforming reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material_component_mass
  • Sources: iea-pvps-lci-photovoltaic-systems-2020
Purchased electricity (electricity_input)

Include applicable fabrication, assembly, testing, ventilation, and packing electricity.

  • Selected flow: Electricity 890a70b7-b677-4e2a-8a1b-7d017e0a10ae
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Submetered electricity converted to MJ and causally allocated
  • Value mode: Foreground record (foreground_record)
  • Specificity: site specific (site_specific)
  • Normalization basis: per 1 kg conforming reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_utility_records
  • Sources: iea-pvps-lci-photovoltaic-systems-2020
Gaseous natural gas (natural_gas_input)

Only for direct on-site drying, curing, or heating; purchased heat is separate.

  • Selected flow: natural gas in the gaseous state 4f19ca0e-7b3b-11dd-ad8b-0800200c9a66
  • Flow property / unit: Volume / m3
  • Amount rule: Metered gas allocated and corrected to declared conditions
  • Value mode: Foreground record (foreground_record)
  • Specificity: site specific (site_specific)
  • Normalization basis: per 1 kg conforming reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_utility_records
  • Sources: iea-pvps-lci-photovoltaic-systems-2020
Industrial oxygen (industrial_oxygen_input)

Only for oxygen-assisted cutting or joining; declare purity and reference conditions.

  • Selected flow: Industrial oxygen bd4b0f96-2090-4806-a648-335ab20ff401
  • Flow property / unit: Volume / m3
  • Amount rule: Metered or cylinder-inventory consumption
  • Value mode: Foreground record (foreground_record)
  • Specificity: technology specific (technology_specific)
  • Normalization basis: per 1 kg conforming reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_utility_records
  • Sources:
Process water (process_water_input)

Only for applicable cleaning, rinsing, or alkaline treatment; cooling water is separate.

  • Selected flow: Process Water 94a04f7e-2d5c-41f0-b182-d54a3b373a02
  • Flow property / unit: Mass / kg
  • Amount rule: Metered mass allocated to the treatment lot
  • Value mode: Foreground record (foreground_record)
  • Specificity: site specific (site_specific)
  • Normalization basis: per 1 kg conforming reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_utility_records
  • Sources: iea-pvps-lci-photovoltaic-systems-2020
Sodium hydroxide (sodium_hydroxide_input)

Only for an applicable treatment bath; declare supplied state and concentration.

  • Selected flow: Sodium hydroxide e0abcced-0611-4c24-9290-5a2c5a0c4169
  • Flow property / unit: Mass / kg
  • Amount rule: Measured product mass consumed
  • Value mode: Foreground record (foreground_record)
  • Specificity: technology specific (technology_specific)
  • Normalization basis: per 1 kg conforming reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material_component_mass
  • Sources:
Corrugated board boxes (corrugated_box_input)

Only when applied before the factory gate; exclude from reference-product mass.

  • Selected flow: corrugated board boxes 4f197bec-7b3b-11dd-ad8b-0800200c9a66
  • Flow property / unit: Mass / kg
  • Amount rule: Measured box mass issued
  • Value mode: Foreground record (foreground_record)
  • Specificity: product specific (product_specific)
  • Normalization basis: per 1 kg conforming reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_packaging_mass
  • Sources: iea-pvps-lci-photovoltaic-systems-2020
Low-density polyethylene protective film (ldpe_film_input)

Only when applied before the factory gate; exclude from reference-product mass.

  • Selected flow: Low-density polyethylene foil (PE-LD) 2cecd3a7-d90e-44b4-aec5-1d9dfb907477
  • Flow property / unit: Mass / kg
  • Amount rule: Measured film mass issued
  • Value mode: Foreground record (foreground_record)
  • Specificity: product specific (product_specific)
  • Normalization basis: per 1 kg conforming reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_packaging_mass
  • Sources: iea-pvps-lci-photovoltaic-systems-2020
Waste flows
Elementary flows

Outputs

Product flows
Conforming parts reference product (reference_product_output)

Record only conforming parts; removable shipment packaging is excluded.

  • Selected flow: Parts of electrical transformers, static converters and inductors d4ea4c05-fc8a-4f2b-b6e9-0ecae8795a95
  • Flow property / unit: Mass / kg
  • Amount rule: Measured dry net conforming mass, normalized to exactly 1 kg
  • Value mode: Fixed value (fixed_value)
  • Specificity: Generic (generic)
  • Normalization basis: 1 kg conforming reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_output_waste_mass
  • Sources: un-cpc-3-0-structure-2025
Waste flows
Ferrous steel fabrication scrap (steel_scrap_output)

Separately collect and retain alloy and coating composition.

  • Selected flow: Steel scrap 8658611f-0588-4eb7-9490-46bcd02b3c2f
  • Flow property / unit: Mass / kg
  • Amount rule: Weighed ferrous scrap
  • Value mode: Foreground record (foreground_record)
  • Specificity: product specific (product_specific)
  • Normalization basis: per 1 kg conforming reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_output_waste_mass
  • Sources:
Copper winding-wire offcuts (copper_scrap_output)

Keep separate from aluminium and mixed metal; retain insulation details.

  • Selected flow: Copper Scrap 4fbbb5f1-560a-4052-ba0c-652c5dfc282e
  • Flow property / unit: Mass / kg
  • Amount rule: Weighed copper scrap
  • Value mode: Foreground record (foreground_record)
  • Specificity: product specific (product_specific)
  • Normalization basis: per 1 kg conforming reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_output_waste_mass
  • Sources:
Aluminium winding-wire offcuts (aluminium_scrap_output)

Keep separate from copper, steel, and mixed metal.

  • Selected flow: Aluminium winding-wire offcuts
  • Flow property / unit: Mass / kg
  • Amount rule: Weighed aluminium offcuts
  • Value mode: Foreground record (foreground_record)
  • Specificity: product specific (product_specific)
  • Normalization basis: per 1 kg conforming reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_output_waste_mass
  • Sources:
Rejected populated printed wiring boards (populated_pwb_waste_output)

Use only after population; bare-board scrap is separate.

  • Selected flow: Waste populated printed wiring board eb5ffe4a-49af-450c-9a31-3efdfd343f8a
  • Flow property / unit: Mass / kg
  • Amount rule: Weighed populated-board rejects
  • Value mode: Foreground record (foreground_record)
  • Specificity: product specific (product_specific)
  • Normalization basis: per 1 kg conforming reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_output_waste_mass
  • Sources: iea-pvps-lci-photovoltaic-systems-2020
Spent alkaline treatment liquor (waste_alkaline_liquor_output)

Keep separate from rinse water; declare pH, NaOH and metal content.

  • Selected flow: Waste Alkaline Liquor ca310225-50c8-4d41-8353-4338b41e19a1
  • Flow property / unit: Mass / kg
  • Amount rule: Measured purge mass
  • Value mode: Foreground record (foreground_record)
  • Specificity: product specific (product_specific)
  • Normalization basis: per 1 kg conforming reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_output_waste_mass
  • Sources:
Elementary flows
Direct fossil carbon dioxide (fossil_co2_output)

Record only direct fossil CO2 from on-site combustion attributable to the lot; exclude upstream electricity and biogenic CO2.

  • Selected flow: carbon dioxide (fossil) 08a91e70-3ddc-11dd-923d-0050c2490048
  • Flow property / unit: Mass / kg
  • Amount rule: Measured stack emission or verified site direct-emission record
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg conforming reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_direct_emission_records
  • Sources:

7. Allocation and Co-product Handling

rule_idApplies toRulesource_ids
allocation_rule_1multiple part families/routesSubdivide independently metered lots before allocation; do not average unlike routes without declaring the production mix.
allocation_rule_2shared recordsAllocate using a causal driver such as machine time, thermal load, board area, or treated area; use mass only when demonstrated.
allocation_rule_3scrap/rejectsKeep scrap as waste without avoided-production credit inside the gate result; disclose any separately modeled co-product.

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_material_component_masspart_fabrication_assemblymaterials/components/chemicalsERP issues/returns; supplier/BOMidentity; lot; issued/returned mass; state; routeReconcile issue minus return to lotkgeach lot; monthly reconcile12 months or full campaignall controlled facilitiessum atomic net input / conforming massspecifications; scales; transactions; BOM log
cp_utility_recordspart_fabrication_assemblyelectricity/gas/oxygen/watermeters; invoices; cylinders; logsreadings; unit; conditions; hours; route; driversubtract readings, correct conditions, causally allocatenative and normalized unitscontinuous/lot; monthlysame as outputall facilitiessum and normalize after allocationcalibration; invoice reconcile; coverage map
cp_packaging_masspart_fabrication_assemblyshipment packagingissues; specificationsmaterial; count; unit mass; returnabilityweigh or count × verified unit masskgconfiguration/lotsame as outputpacking sitessum non-returnable packaging / net productscale; drawing; purchase spec
cp_output_waste_masspart_fabrication_assemblyproduct/wastescales; reject log; waste ticketspart; lot; product/waste mass; composition; destinationweigh and reconcile each atomic outputkglot/dispatchsame as inputsall facilitiessum by output / conforming masscalibration; release; transfer note; mass balance
cp_direct_emission_recordspart_fabrication_assemblyfossil CO2stack or verified inventorysource; fuel; mass; period; route; driveruse verified direct emissions and causally allocatekg CO2monitoring interval; annual reconcilesame as fuel/outputon-site combustionsum by source / conforming massmonitoring; verification; fuel reconcile

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
calculation_rule_1all rowsnormalized amount = lot flow / dry net conforming product massatomic record; output massamount per 1 kg
calculation_rule_2electricityMJ = kWh × 3.6meter recordMJ
calculation_rule_3shared recordsallocated flow = shared amount × causal-driver share; shares sum to 1shared record; driverlot flow
calculation_rule_4mass balanceresidual = mass inputs - product - measured wastes - direct mass emissions; investigate, never force-balanceconsistent mass recordsresidual/explanation

Data Quality Requirements

requirement_idApplies toRequirementEvidence
quality_requirement_1identityRetain part/drawing/BOM, recipient apparatus, acceptance, and CPC scope.drawing; BOM; release; un-cpc-3-0-structure-2025; eu-transformer-regulation-548-2014
quality_requirement_2completenessReconcile route with material, utility, reject, and packaging records; explain omissions.traveler; meter map; oria-et-al-transformer-lca-review-2026; iea-pvps-lci-photovoltaic-systems-2020
quality_requirement_3representativenessUse a common period/site and disclose outsourcing, mix, and obsolete data.period reconciliation; facility/supplier records
quality_requirement_4measurementRetain calibration, gas conditions, allocation coverage, uncertainty, and residuals.certificates; invoices; worksheets
quality_requirement_5flow identityVerify public state-100 UUIDs and retain exact atomic names for unresolved flows.receipts; row audit; unresolved list

9. Validation Rules

rule_idApplies toRulesource_ids
validation_rule_1categoryReject complete apparatus, generic material, or service outputs.un-cpc-3-0-structure-2025; eu-transformer-regulation-548-2014
validation_rule_2reference flowConfirm exactly 1 kg dry net conforming part; exclude and separately report removable packaging.
validation_rule_3completenessConfirm each applicable material, utility, waste, and direct emission is one atomic row; support absent routes.oria-et-al-transformer-lca-review-2026; iea-pvps-lci-photovoltaic-systems-2020
validation_rule_4calculationRecalculate normalization, conversion, allocation shares, and residual; reject unexplained differences.
validation_rule_5identity/unitVerify UUID, flow type, property, unit group, Chinese baseName, and condition; never use a proxy for unresolved identity.
validation_rule_6disclosureConfirm sources, records, site, period, part family, materials, board state, treatment, and packaging.

10. Published Dataset Profile

FieldValue
dataset_roleforeground manufacturing dataset eligible as secondary_dataset or background_dataset after review
downstream_usecradle-to-gate footprints and upstream input to complete-apparatus processes/lifecycle models
allowed_usematching part family, BOM, route, site, period, state, and allocation basis
excluded_usecomplete-apparatus losses, installation, maintenance, end-of-life, or unmatched part/board state
required_metadataPCR; part/recipient; BOM/drawing; materials; insulation; board state; route/treatment; site/period; mass; packaging; UUIDs; allocation
required_quality_disclosuresource/meter coverage; supplier share; period; calibration; residual; allocation/sensitivity; unresolved evidence; exclusions/outsourcing
update_triggermaterial/BOM/route/board/site/energy/treatment/packaging/allocation change; obsolete data; resolved identity

11. Data Sources

Source idTypeReferenceUsed for
un-cpc-3-0-structure-2025official_guidanceUN Statistics Division, CPC 3.0 Structure, 30 June 2025, https://unstats.un.org/unsd/classifications/Econ/Download/In%20Text/CPC_Ver_3.0_Structure_30Jun2025.csv (retrieved 2026-09-04)CPC 46132 identity/hierarchy
eu-transformer-regulation-548-2014official_guidanceCommission Regulation (EU) No 548/2014, CELEX 32014R0548, https://eur-lex.europa.eu/legal-content/EN/ALL/?uri=CELEX:32014R0548 (accessed 2026-09-04)Finished-transformer and winding definitions
oria-et-al-transformer-lca-review-2026literatureOria et al., LCA of transformers: a systematic review of methods, dominant contributors and research gaps (2026), https://doi.org/10.1007/s11367-026-02664-7Transformer components, materials, scope, quality
iea-pvps-lci-photovoltaic-systems-2020datasetFrischknecht et al., IEA PVPS T12-19:2020, ISBN 978-3-907281-14-7, https://www.iea-pvps.org/wp-content/uploads/2020/12/IEA-PVPS-LCI-report-2020.pdfOriginal inverter LCI: components, utilities, processing, packaging, water, waste

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 3
Rule IDApplies toRuleSource IDs
boundary_rule_1foregroundInclude applicable forming, winding, board assembly, molding, joining, treatment, testing, rejects, utilities, direct emissions and packing through factory gate.oria-et-al-transformer-lca-review-2026, iea-pvps-lci-photovoltaic-systems-2020
boundary_rule_2upstream linkageUse linked upstream datasets for purchased inputs and inbound transport; never hide them in an aggregate input.iea-pvps-lci-photovoltaic-systems-2020
boundary_rule_3exclusionsExclude complete apparatus manufacture/use, losses, installation, distribution and end-of-life unless separately expanded and reported.eu-transformer-regulation-548-2014, oria-et-al-transformer-lca-review-2026
Allocation rules · 3
Rule IDApplies toRuleSource IDs
allocation_rule_1multiple part families/routesSubdivide independently metered lots before allocation; do not average unlike routes without declaring the production mix.
allocation_rule_2shared recordsAllocate using a causal driver such as machine time, thermal load, board area, or treated area; use mass only when demonstrated.
allocation_rule_3scrap/rejectsKeep scrap as waste without avoided-production credit inside the gate result; disclose any separately modeled co-product.
Validation rules · 6
Rule IDApplies toRuleSource IDs
validation_rule_1categoryReject complete apparatus, generic material, or service outputs.un-cpc-3-0-structure-2025, eu-transformer-regulation-548-2014
validation_rule_2reference flowConfirm exactly 1 kg dry net conforming part; exclude and separately report removable packaging.
validation_rule_3completenessConfirm each applicable material, utility, waste, and direct emission is one atomic row; support absent routes.oria-et-al-transformer-lca-review-2026, iea-pvps-lci-photovoltaic-systems-2020
validation_rule_4calculationRecalculate normalization, conversion, allocation shares, and residual; reject unexplained differences.
validation_rule_5identity/unitVerify UUID, flow type, property, unit group, Chinese baseName, and condition; never use a proxy for unresolved identity.
validation_rule_6disclosureConfirm sources, records, site, period, part family, materials, board state, treatment, and packaging.
Processes and inputs/outputs · 1
Process IDProcess nameInput flowsOutput flows
part_fabrication_assemblyRoute-qualified part fabrication, assembly, testing and packing167

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page

1. Scope and Applicability2. Product Category Identity3. Reference Flow4. Measurement and Unit Rules5. System BoundaryBoundary Abstraction6. Process Inventory StructureProcess MapProcess: Route-qualified part fabrication, assembly, testing and packing (part_fabrication_assembly)InputsProduct flowsElectrical steel sheet for laminated cores (electrical_steel_input)Insulated conductor for windings (magnet_wire_input)Ferrite core for high-frequency magnetic parts (ferrite_core_input)Cellulose electrical insulation paper (electrical_insulation_paper_input)Non-alloy steel for enclosure or hardware (non_alloy_steel_input)Printed wire board for converter assembly (printed_wire_board_input)Lead-free flux-free solder (lead_free_solder_input)Power semiconductor device (power_semiconductor_input)Glass-fibre-reinforced polyamide granulate (glass_fibre_polyamide_input)Purchased electricity (electricity_input)Gaseous natural gas (natural_gas_input)Industrial oxygen (industrial_oxygen_input)Process water (process_water_input)Sodium hydroxide (sodium_hydroxide_input)Corrugated board boxes (corrugated_box_input)Low-density polyethylene protective film (ldpe_film_input)Waste flowsElementary flowsOutputsProduct flowsConforming parts reference product (reference_product_output)Waste flowsFerrous steel fabrication scrap (steel_scrap_output)Copper winding-wire offcuts (copper_scrap_output)Aluminium winding-wire offcuts (aluminium_scrap_output)Rejected populated printed wiring boards (populated_pwb_waste_output)Spent alkaline treatment liquor (waste_alkaline_liquor_output)Elementary flowsDirect fossil carbon dioxide (fossil_co2_output)7. Allocation and Co-product Handling8. Foreground Data Collection, Calculation, and Quality RulesData Collection ProtocolsCalculation RulesData Quality Requirements9. Validation Rules10. Published Dataset Profile11. Data Sources