1. Scope and Applicability

Gate-to-gate production of tin or declared tin-alloy bars, rods, solid profiles and wire from received metal feedstock through casting and/or extrusion, rolling, drawing, straightening, cutting and finishing. Excludes unwrought tin, sheet, strip, foil, powder, tubes, fabricated articles, use and end-of-life.

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.metal-products-machinery-and-equipment.basic-metals.tin-bars-rods-profiles-and-wire
classification_refsCPC 3.0 41547
covered_productsTin and declared tin-alloy bars, rods, solid profiles and wire
excluded_productsUnwrought tin; sheet, strip, foil, powder, tubes and fabricated articles
representative_productTin rod
production_routeDeclared casting/forming/finishing route
market_stateSaleable semi-finished solid product at factory gate

3. Reference Flow

FieldValue
WhatConforming saleable covered product
How much1 kg net saleable product
How wellComposition, form, dimensions, temper, surface and specification declared
How long or cycleReporting-period production campaign
reference_flow_linkNet factory-gate mass after internal returns and rejects
FieldValue
Reference amount1
Reference product flowTin Rod e9c72b13-0d60-4d67-a1c9-b0c963ec62cf
Reference flow propertyMass 93a60a56-a3c8-11da-a746-0800200b9a66
Reference unit groupUnits of mass 93a60a57-a4c8-11da-a746-0800200c9a66
Reference unitkg
Required qualifiersform; composition; dimensions; temper; surface; route; geography; period

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
reference_massmass flowsMass 93a60a56-a3c8-11da-a746-0800200b9a66kgUse a consistent mass basis and normalize net output to 1 kg.

5. System Boundary

Boundary Abstraction

FieldValue
declared_starting_conditionReceived refined tin or declared tin-alloy feedstock
starting_condition_roleUpstream production represented by linked input datasets
product_classification_scopeCovered solid semi-finished forms
recursive_input_ruleRecord same-category off-site feedstock once; internal scrap does not cross the boundary
upstream_dataset_requirementRepresentative datasets for purchased inputs
disclosureDeclare route, alloy, internal scrap loop and surface treatment
rule_idApplies toRulesource_ids
boundary_gate_to_gateforeground systemInclude on-site forming and finishing; exclude use and end-of-life.un-cpc-3-0-structure-2025

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
tin_semifabricationTin semi-fabricationrequiredAlwaysforeground production1 kg net product

Process: Tin semi-fabrication (tin_semifabrication)

Inputs

Product flows
Tin feedstock (tin_feedstock)

Record the received mass of the declared feedstock grade crossing the factory boundary.

  • Selected flow: Tin metal feedstock
  • Flow property / unit: Mass / kg
  • Amount rule: measured received mass
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg net product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_mass
  • Sources:
Purchased electricity (electricity)

Record electricity consumed by included production equipment and allocated auxiliaries.

  • Selected flow: Electricity 890a70b7-b677-4e2a-8a1b-7d017e0a10ae
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: metered attributable electricity
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_energy
  • Sources:
Waste flows
Elementary flows

Outputs

Product flows
Reference product (reference_product)

Record net conforming product mass after internal returns and rejects.

  • Selected flow: Tin Rod e9c72b13-0d60-4d67-a1c9-b0c963ec62cf
  • Flow property / unit: Mass / kg
  • Amount rule: fixed reference amount
  • Value mode: Fixed value (fixed_value)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: 1 kg net product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Identity reference (identity_reference)
  • Collection protocol:
  • Sources:
Waste flows
Tin-bearing process scrap (process_scrap)

Record only segregated scrap leaving the foreground boundary; exclude internal returns.

  • Selected flow: Tin scrap 72bbff5c-c26f-4b7b-971e-df634b72ea28
  • Flow property / unit: Mass / kg
  • Amount rule: weighed off-site mass; exclude internal returns
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_mass
  • Sources:
Elementary flows

7. Allocation and Co-product Handling

rule_idApplies toRulesource_ids
allocation_subdivisionshared productionSubdivide first; allocate residual shared burdens by net mass and disclose sensitivity.

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_masstin_semifabricationmaterial massscale recordstime; grade; gross; tare; dispositioncalibrated scaleskgeach lotrepresentative 12 months or disclosed campaignincluded linessum and normalizecalibration and reconciliation
cp_energytin_semifabricationelectricitymeter recordsmeter; period; energysubmeter or documented allocationkWh or MJmonthlyproduction periodincluded equipmentsubtract exclusions and normalizeinvoices and meter checks

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
normalizeall rowsallocated quantity divided by net product massquantity; net massper kg quantity

Data Quality Requirements

requirement_idApplies toRequirementEvidence
dq_balancemetal flowsReconcile feedstock, product, scrap, stock change and internal returns.scale records and reconciliation

9. Validation Rules

rule_idApplies toRulesource_ids
validate_referencereference flowRequire 1 kg and all qualifiers.
validate_inventoryinventoryRequire atomic flows, UUID status, aligned periods and mass balance.

10. Published Dataset Profile

FieldValue
dataset_roleforeground production dataset
downstream_useprocess and lifecyclemodel construction
allowed_usedeclared covered product and route
excluded_useupstream refining, use and end-of-life
required_metadataform; composition; dimensions; route; geography; period; allocation
required_quality_disclosuremetering, mass balance, unresolved UUIDs and gaps
update_triggermaterial boundary, route, alloy, energy or yield change

11. Data Sources

Source idTypeReferenceUsed for
un-cpc-3-0-structure-2025Official guidance (official_guidance)CPC Version 3.0 Structure, 30 June 2025; https://unstats.un.org/unsd/classifications/Econ/Download/In%20Text/CPC_Ver_3.0_Structure_30Jun2025.csv; retrieved 2026-09-04Verified original product identity text

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 1
Rule IDApplies toRuleSource IDs
boundary_gate_to_gateforeground systemInclude on-site forming and finishing; exclude use and end-of-life.un-cpc-3-0-structure-2025
Allocation rules · 1
Rule IDApplies toRuleSource IDs
allocation_subdivisionshared productionSubdivide first; allocate residual shared burdens by net mass and disclose sensitivity.
Validation rules · 2
Rule IDApplies toRuleSource IDs
validate_referencereference flowRequire 1 kg and all qualifiers.
validate_inventoryinventoryRequire atomic flows, UUID status, aligned periods and mass balance.