Sausages and similar products of meat, offal or blood · Process: Hygiene cleaning and sanitation (hygiene_cleaning_sanitation)
Sausages and similar products of meat, offal or blood · Process: Hygiene cleaning and sanitation (hygiene_cleaning_sanitation): Foreground cleaning, rinsing, sanitation…
- Lifecycle status
- Candidate
- Content maturity
- Authored methodology
- Current version
- No published version
- Readiness
- Review required
- Last updated
Methodology and translation states come from the source record; publishing this website does not change their review status.
Content languages
Status, classification and source details
Readiness
- Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.
Classification mapping
Source
Process: Hygiene cleaning and sanitation (hygiene_cleaning_sanitation)
Foreground cleaning, rinsing, sanitation, and residue removal. Always include product-contact and area cleaning attributable to the locked production campaign.
Inputs
Product flows
Use Potable cleaning water (hygiene_input_water)
Potable cleaning water is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Potable cleaning water
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_cleaning_water_mass - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Potable cleaning water physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Use Grid electricity, medium voltage (hygiene_input_electricity)
Grid electricity, medium voltage is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Grid electricity, medium voltage
- Flow property / unit: Energy / kWh
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_stage_electricity - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Grid electricity, medium voltage physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain meter resolution, calibration status, meter coverage, time interval, and any batch attribution calculation.
Use Purchased steam (hygiene_input_purchased_steam)
Purchased steam is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Purchased steam
- Flow property / unit: Energy / MJ
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_purchased_heat - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Purchased steam physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain meter resolution, calibration status, meter coverage, time interval, and any batch attribution calculation.
Use Purchased hot water (hygiene_input_purchased_hot_water)
Purchased hot water is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Purchased hot water
- Flow property / unit: Energy / MJ
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_purchased_heat - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Purchased hot water physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain meter resolution, calibration status, meter coverage, time interval, and any batch attribution calculation.
Use Onsite-generated steam (hygiene_input_onsite_steam)
Onsite-generated steam is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Onsite-generated steam
- Flow property / unit: Energy / MJ
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_internal_heat_output - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Onsite-generated steam physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain meter resolution, calibration status, meter coverage, time interval, and any batch attribution calculation.
Use Onsite-generated hot water (hygiene_input_onsite_hot_water)
Onsite-generated hot water is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Onsite-generated hot water
- Flow property / unit: Energy / MJ
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_internal_heat_output - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Onsite-generated hot water physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain meter resolution, calibration status, meter coverage, time interval, and any batch attribution calculation.
Use Natural gas (hygiene_input_natural_gas)
Natural gas is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Natural gas
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_fuel_inventory - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Natural gas physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Use Diesel fuel (hygiene_input_diesel)
Diesel fuel is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Diesel fuel
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_fuel_inventory - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Diesel fuel physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Use Liquefied petroleum gas (hygiene_input_lpg)
Liquefied petroleum gas is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Liquefied petroleum gas
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_fuel_inventory - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Liquefied petroleum gas physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Use Sodium hydroxide (hygiene_input_sodium_hydroxide)
Sodium hydroxide is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Sodium hydroxide
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_cleaning_chemical_mass - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Sodium hydroxide physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Use Nitric acid (hygiene_input_nitric_acid)
Nitric acid is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Nitric acid
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_cleaning_chemical_mass - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Nitric acid physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Use Phosphoric acid (hygiene_input_phosphoric_acid)
Phosphoric acid is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Phosphoric acid
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_cleaning_chemical_mass - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Phosphoric acid physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Use Peracetic acid (hygiene_input_peracetic_acid)
Peracetic acid is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Peracetic acid
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_cleaning_chemical_mass - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Peracetic acid physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Use Sodium hypochlorite (hygiene_input_sodium_hypochlorite)
Sodium hypochlorite is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Sodium hypochlorite
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_cleaning_chemical_mass - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Sodium hypochlorite physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Waste flows
Elementary flows
Outputs
Product flows
Waste flows
Remove High-strength sausage-processing cleaning wastewater (hygiene_output_high_strength)
High-strength sausage-processing cleaning wastewater is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: High-strength sausage-processing cleaning wastewater
- Flow property / unit: Volume / m3
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wastewater_volume - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when High-strength sausage-processing cleaning wastewater physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain meter resolution, calibration status, sampling interval, density conversion where used, and temporal coverage.
Remove Low-strength final-rinse wastewater (hygiene_output_final_rinse)
Low-strength final-rinse wastewater is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Low-strength final-rinse wastewater
- Flow property / unit: Volume / m3
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wastewater_volume - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Low-strength final-rinse wastewater physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain meter resolution, calibration status, sampling interval, density conversion where used, and temporal coverage.
Remove Pork sausage meat floor residue (hygiene_output_pork_residue)
Pork sausage meat floor residue is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Pork sausage meat floor residue
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_material_waste_mass - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Pork sausage meat floor residue physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Remove Beef sausage meat floor residue (hygiene_output_beef_residue)
Beef sausage meat floor residue is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Beef sausage meat floor residue
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_material_waste_mass - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Beef sausage meat floor residue physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Remove Pig blood product floor residue (hygiene_output_pig_blood_residue)
Pig blood product floor residue is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Pig blood product floor residue
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_material_waste_mass - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Pig blood product floor residue physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Remove Pork liver product floor residue (hygiene_output_pork_liver_residue)
Pork liver product floor residue is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Pork liver product floor residue
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_material_waste_mass - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Pork liver product floor residue physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Remove Chicken galantine floor residue (hygiene_output_chicken_galantine_residue)
Chicken galantine floor residue is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Chicken galantine floor residue
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_material_waste_mass - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Chicken galantine floor residue physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Remove Spent sodium hydroxide cleaning solution (hygiene_output_spent_caustic)
Spent sodium hydroxide cleaning solution is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Spent sodium hydroxide cleaning solution
- Flow property / unit: Volume / m3
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wastewater_volume - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Spent sodium hydroxide cleaning solution physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain meter resolution, calibration status, sampling interval, density conversion where used, and temporal coverage.
Remove Spent nitric acid cleaning solution (hygiene_output_spent_nitric)
Spent nitric acid cleaning solution is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Spent nitric acid cleaning solution
- Flow property / unit: Volume / m3
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wastewater_volume - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Spent nitric acid cleaning solution physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain meter resolution, calibration status, sampling interval, density conversion where used, and temporal coverage.
Remove Spent phosphoric acid cleaning solution (hygiene_output_spent_phosphoric)
Spent phosphoric acid cleaning solution is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Spent phosphoric acid cleaning solution
- Flow property / unit: Volume / m3
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wastewater_volume - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Spent phosphoric acid cleaning solution physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain meter resolution, calibration status, sampling interval, density conversion where used, and temporal coverage.
Remove Spent peracetic acid sanitising solution (hygiene_output_spent_peracetic)
Spent peracetic acid sanitising solution is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Spent peracetic acid sanitising solution
- Flow property / unit: Volume / m3
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wastewater_volume - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Spent peracetic acid sanitising solution physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain meter resolution, calibration status, sampling interval, density conversion where used, and temporal coverage.
Remove Spent sodium hypochlorite sanitising solution (hygiene_output_spent_hypochlorite)
Spent sodium hypochlorite sanitising solution is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Spent sodium hypochlorite sanitising solution
- Flow property / unit: Volume / m3
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wastewater_volume - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024,codex-cxc-58-2005 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Spent sodium hypochlorite sanitising solution physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain meter resolution, calibration status, sampling interval, density conversion where used, and temporal coverage.
Elementary flows
Process: Onsite heat generation (onsite_heat_generation)
Foreground boiler or heater operation for internally supplied steam or hot water. Include only when steam or hot water is generated within the foreground facility.
Inputs
Product flows
Use Natural gas (heat_input_natural_gas)
Natural gas is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Natural gas
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_fuel_inventory - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Natural gas physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Use Diesel fuel (heat_input_diesel)
Diesel fuel is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Diesel fuel
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_fuel_inventory - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Diesel fuel physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Use Liquefied petroleum gas (heat_input_lpg)
Liquefied petroleum gas is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Liquefied petroleum gas
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_fuel_inventory - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Liquefied petroleum gas physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Use Grid electricity, medium voltage (heat_input_electricity)
Grid electricity, medium voltage is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Grid electricity, medium voltage
- Flow property / unit: Energy / kWh
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_stage_electricity - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Grid electricity, medium voltage physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain meter resolution, calibration status, meter coverage, time interval, and any batch attribution calculation.
Use Boiler feedwater (heat_input_feedwater)
Boiler feedwater is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Boiler feedwater
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_process_water_mass - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Boiler feedwater physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Waste flows
Elementary flows
Outputs
Product flows
Produce Onsite-generated steam (heat_output_steam)
Onsite-generated steam is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Onsite-generated steam
- Flow property / unit: Energy / MJ
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per measured onsite heat-output campaign attributable to the locked product batch
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_internal_heat_output - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Onsite-generated steam physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain meter resolution, calibration status, meter coverage, time interval, and any batch attribution calculation.
Produce Onsite-generated hot water (heat_output_hot_water)
Onsite-generated hot water is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Onsite-generated hot water
- Flow property / unit: Energy / MJ
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per measured onsite heat-output campaign attributable to the locked product batch
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_internal_heat_output - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Onsite-generated hot water physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain meter resolution, calibration status, meter coverage, time interval, and any batch attribution calculation.
Waste flows
Remove Boiler blowdown wastewater (heat_waste_blowdown)
Boiler blowdown wastewater is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Boiler blowdown wastewater
- Flow property / unit: Volume / m3
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wastewater_volume - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Boiler blowdown wastewater physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain meter resolution, calibration status, sampling interval, density conversion where used, and temporal coverage.
Remove Spent ion-exchange resin (heat_waste_resin)
Spent ion-exchange resin is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Spent ion-exchange resin
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_material_waste_mass - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Spent ion-exchange resin physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Elementary flows
Release Fossil carbon dioxide to air (heat_release_co2)
Fossil carbon dioxide to air is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Fossil carbon dioxide to air
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_direct_emission_measurement - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Fossil carbon dioxide to air physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain sampling or mass-balance method, detection limit, temporal representativeness, conversion records, and analytical uncertainty.
Release Nitrogen oxides (NOx) to air (heat_release_nox)
Nitrogen oxides (NOx) to air is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Nitrogen oxides (NOx) to air
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_direct_emission_measurement - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Nitrogen oxides (NOx) to air physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain sampling or mass-balance method, detection limit, temporal representativeness, conversion records, and analytical uncertainty.
Release Sulfur oxides (SOx) to air (heat_release_sox)
Sulfur oxides (SOx) to air is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Sulfur oxides (SOx) to air
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_direct_emission_measurement - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Sulfur oxides (SOx) to air physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain sampling or mass-balance method, detection limit, temporal representativeness, conversion records, and analytical uncertainty.
Release Particulate matter, ≤2.5 µm, to air (heat_release_pm25)
Particulate matter, ≤2.5 µm, to air is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Particulate matter, ≤2.5 µm, to air
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_direct_emission_measurement - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Particulate matter, ≤2.5 µm, to air physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain sampling or mass-balance method, detection limit, temporal representativeness, conversion records, and analytical uncertainty.
Release Carbon monoxide to air (heat_release_co)
Carbon monoxide to air is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Carbon monoxide to air
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_direct_emission_measurement - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Carbon monoxide to air physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain sampling or mass-balance method, detection limit, temporal representativeness, conversion records, and analytical uncertainty.
Process: Onsite wastewater treatment (onsite_wastewater_treatment)
Foreground physical, chemical, and biological treatment of the two named wastewater streams. Include only when wastewater is treated inside the foreground facility boundary.
Inputs
Product flows
Use Grid electricity, medium voltage (wwtp_input_electricity)
Grid electricity, medium voltage is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Grid electricity, medium voltage
- Flow property / unit: Energy / kWh
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_stage_electricity - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Grid electricity, medium voltage physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain meter resolution, calibration status, meter coverage, time interval, and any batch attribution calculation.
Use Ferric chloride (wwtp_input_ferric_chloride)
Ferric chloride is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Ferric chloride
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwtp_chemical_mass - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Ferric chloride physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Use Aluminium sulfate (wwtp_input_aluminium_sulfate)
Aluminium sulfate is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Aluminium sulfate
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwtp_chemical_mass - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Aluminium sulfate physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Use Polyacrylamide flocculant (wwtp_input_polyacrylamide)
Polyacrylamide flocculant is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Polyacrylamide flocculant
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwtp_chemical_mass - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Polyacrylamide flocculant physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Use Sodium hydroxide (wwtp_input_sodium_hydroxide)
Sodium hydroxide is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Sodium hydroxide
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwtp_chemical_mass - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Sodium hydroxide physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Use Calcium hydroxide (wwtp_input_calcium_hydroxide)
Calcium hydroxide is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Calcium hydroxide
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwtp_chemical_mass - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Calcium hydroxide physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Waste flows
Treat High-strength sausage-processing cleaning wastewater (wwtp_input_high_strength)
High-strength sausage-processing cleaning wastewater is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: High-strength sausage-processing cleaning wastewater
- Flow property / unit: Volume / m3
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wastewater_volume - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when High-strength sausage-processing cleaning wastewater physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain meter resolution, calibration status, sampling interval, density conversion where used, and temporal coverage.
Treat Low-strength final-rinse wastewater (wwtp_input_final_rinse)
Low-strength final-rinse wastewater is recorded as one atomic input exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Low-strength final-rinse wastewater
- Flow property / unit: Volume / m3
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wastewater_volume - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Low-strength final-rinse wastewater physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain meter resolution, calibration status, sampling interval, density conversion where used, and temporal coverage.
Elementary flows
Outputs
Product flows
Waste flows
Remove Treated sausage-processing wastewater (wwtp_output_treated_effluent)
Treated sausage-processing wastewater is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Treated sausage-processing wastewater
- Flow property / unit: Volume / m3
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wastewater_volume - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Treated sausage-processing wastewater physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain meter resolution, calibration status, sampling interval, density conversion where used, and temporal coverage.
Remove Dissolved-air-flotation sludge (wwtp_output_daf_sludge)
Dissolved-air-flotation sludge is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Dissolved-air-flotation sludge
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sludge_mass - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Dissolved-air-flotation sludge physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Remove Biological wastewater-treatment sludge (wwtp_output_biological_sludge)
Biological wastewater-treatment sludge is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Biological wastewater-treatment sludge
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sludge_mass - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Biological wastewater-treatment sludge physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Remove Wastewater bar-screen solids (wwtp_output_screenings)
Wastewater bar-screen solids is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Wastewater bar-screen solids
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_material_waste_mass - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Wastewater bar-screen solids physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Remove Separated pork-fat scum (wwtp_output_pork_fat_scum)
Separated pork-fat scum is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Separated pork-fat scum
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_material_waste_mass - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Separated pork-fat scum physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Remove Separated beef-fat scum (wwtp_output_beef_fat_scum)
Separated beef-fat scum is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Separated beef-fat scum
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_material_waste_mass - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Separated beef-fat scum physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Remove Spent activated carbon (wwtp_output_activated_carbon)
Spent activated carbon is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Spent activated carbon
- Flow property / unit: Mass / kg
- Amount rule: Record the measured foreground amount crossing this process boundary for the locked batch.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_material_waste_mass - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Spent activated carbon physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain scale resolution, calibration status, tare method, moisture basis where relevant, and batch reconciliation difference.
Elementary flows
Release Chemical oxygen demand to water (wwtp_release_cod)
Chemical oxygen demand to water is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Chemical oxygen demand to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate the batch-attributable amount only from the foreground records defined by the linked protocol.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wastewater_pollutant_load - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Chemical oxygen demand to water physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain sampling or mass-balance method, detection limit, temporal representativeness, conversion records, and analytical uncertainty.
Release Biochemical oxygen demand, 5-day, to water (wwtp_release_bod5)
Biochemical oxygen demand, 5-day, to water is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Biochemical oxygen demand, 5-day, to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate the batch-attributable amount only from the foreground records defined by the linked protocol.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wastewater_pollutant_load - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Biochemical oxygen demand, 5-day, to water physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain sampling or mass-balance method, detection limit, temporal representativeness, conversion records, and analytical uncertainty.
Release Total suspended solids to water (wwtp_release_tss)
Total suspended solids to water is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Total suspended solids to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate the batch-attributable amount only from the foreground records defined by the linked protocol.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wastewater_pollutant_load - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Total suspended solids to water physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain sampling or mass-balance method, detection limit, temporal representativeness, conversion records, and analytical uncertainty.
Release Ammonium nitrogen to water (wwtp_release_ammonium)
Ammonium nitrogen to water is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Ammonium nitrogen to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate the batch-attributable amount only from the foreground records defined by the linked protocol.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wastewater_pollutant_load - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Ammonium nitrogen to water physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain sampling or mass-balance method, detection limit, temporal representativeness, conversion records, and analytical uncertainty.
Release Nitrate nitrogen to water (wwtp_release_nitrate)
Nitrate nitrogen to water is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Nitrate nitrogen to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate the batch-attributable amount only from the foreground records defined by the linked protocol.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wastewater_pollutant_load - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Nitrate nitrogen to water physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain sampling or mass-balance method, detection limit, temporal representativeness, conversion records, and analytical uncertainty.
Release Phosphate phosphorus to water (wwtp_release_phosphate)
Phosphate phosphorus to water is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Phosphate phosphorus to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate the batch-attributable amount only from the foreground records defined by the linked protocol.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wastewater_pollutant_load - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Phosphate phosphorus to water physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain sampling or mass-balance method, detection limit, temporal representativeness, conversion records, and analytical uncertainty.
Release Chloride to water (wwtp_release_chloride)
Chloride to water is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Chloride to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate the batch-attributable amount only from the foreground records defined by the linked protocol.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wastewater_pollutant_load - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Chloride to water physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain sampling or mass-balance method, detection limit, temporal representativeness, conversion records, and analytical uncertainty.
Release Pork fat to water (wwtp_release_pork_fat)
Pork fat to water is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Pork fat to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate the batch-attributable amount only from the foreground records defined by the linked protocol.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wastewater_pollutant_load - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Pork fat to water physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain sampling or mass-balance method, detection limit, temporal representativeness, conversion records, and analytical uncertainty.
Release Beef fat to water (wwtp_release_beef_fat)
Beef fat to water is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Beef fat to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate the batch-attributable amount only from the foreground records defined by the linked protocol.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wastewater_pollutant_load - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Beef fat to water physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain sampling or mass-balance method, detection limit, temporal representativeness, conversion records, and analytical uncertainty.
Release Methane to air (wwtp_release_methane)
Methane to air is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Methane to air
- Flow property / unit: Mass / kg
- Amount rule: Calculate the batch-attributable amount only from the foreground records defined by the linked protocol.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wastewater_pollutant_load - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Methane to air physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain sampling or mass-balance method, detection limit, temporal representativeness, conversion records, and analytical uncertainty.
Release Nitrous oxide to air (wwtp_release_nitrous_oxide)
Nitrous oxide to air is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Nitrous oxide to air
- Flow property / unit: Mass / kg
- Amount rule: Calculate the batch-attributable amount only from the foreground records defined by the linked protocol.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wastewater_pollutant_load - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Nitrous oxide to air physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain sampling or mass-balance method, detection limit, temporal representativeness, conversion records, and analytical uncertainty.
Release Biogenic carbon dioxide to air (wwtp_release_biogenic_co2)
Biogenic carbon dioxide to air is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Biogenic carbon dioxide to air
- Flow property / unit: Mass / kg
- Amount rule: Calculate the batch-attributable amount only from the foreground records defined by the linked protocol.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wastewater_pollutant_load - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Biogenic carbon dioxide to air physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain sampling or mass-balance method, detection limit, temporal representativeness, conversion records, and analytical uncertainty.
Release Ammonia to air (wwtp_release_ammonia)
Ammonia to air is recorded as one atomic output exchange in this process; it is not a proxy for any other material, carrier, waste, or emission.
- Selected flow: Ammonia to air
- Flow property / unit: Mass / kg
- Amount rule: Calculate the batch-attributable amount only from the foreground records defined by the linked protocol.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming saleable reference product at the facility gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wastewater_pollutant_load - Sources:
eu-pef-2021-2279,jrc-sa-bref-2024 - UUID status: Unresolved; blank pending exact dual-kernel verification.
- Applicability: Record only when Ammonia to air physically crosses the process boundary for the single locked product formulation and treatment sequence; otherwise mark this atomic row not applicable.
- Uncertainty: Retain sampling or mass-balance method, detection limit, temporal representativeness, conversion records, and analytical uncertainty.
7. Allocation and Co-product Handling
| rule_id | Applies to | Rule | source_ids |
|---|---|---|---|
avoid_allocation | all processes | Use batch-specific recipe, submeter, production-time, equipment-state, and waste records to avoid allocation wherever possible. | eu-pef-2021-2279 |
recipe_partition | shared formulation records | Partition material inputs by the actual locked batch recipe and scale tickets; do not use a category-average formula. | eu-pef-2021-2279 |
utility_partition | shared utilities | Partition shared electricity, heat, refrigeration, cleaning, and wastewater records using measured process time, meter intervals, mass throughput, or another documented causal driver. | eu-pef-2021-2279 |
physical_relation | multi-output processes | Use a physical causal relation when it explains resource use or emission generation; document the relation and calculation. | eu-pef-2021-2279 |
mass_allocation | unresolved physical split | Use mass allocation only when no more direct physical relation is available and all output masses share the same campaign basis. | eu-pef-2021-2279 |
economic_residual | residual multifunctionality | Use economic allocation only as a documented residual method when physical relations cannot represent the function; retain price period, geography, and sensitivity disclosure. | eu-pef-2021-2279 |
rework_once | internal rework | Do not allocate a second burden to internal rework that remains within the same locked batch mass balance. | eu-pef-2021-2279 |
waste_no_credit | waste outputs | Do not assign an avoided-product credit to a waste stream without a separately evidenced downstream substitution model outside this foreground package. | eu-pef-2021-2279 |
route_no_average | product families | Do not average fresh, cooked, fermented, dried, smoked, chilled, frozen, meat, organ, or blood routes into one reference output. | un-cpc-3-2025, eu-pef-2021-2279, codex-cxs-192-1995 |
Raw downloads
These files are byte-identical to the canonical files for this revision in the repository.
Complete field inspector
Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.