Meat of guinea fowl, frozen · Process: Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch (frozen_packaging_storage)
Meat of guinea fowl, frozen · Process: Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch (frozen_packaging_storage): Frozen…
- Lifecycle status
- Candidate
- Content maturity
- Authored methodology
- Current version
- No published version
- Readiness
- Review required
- Last updated
Methodology and translation states come from the source record; publishing this website does not change their review status.
Content languages
Status, classification and source details
Readiness
- Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.
Classification mapping
Source
Process: Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch (frozen_packaging_storage)
Inputs
Product flows
Frozen guinea fowl meat (packaging_frozen_meat_input)
Frozen guinea fowl meat enters the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Frozen guinea fowl meat
- Flow property / unit: Mass / kg
- Amount rule: Use released-lot net mass after documented quality, frozen-state and product-temperature checks.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_product_release - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Electricity, facility supply (frozen_storage_electricity)
Electricity, facility supply enters the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Electricity, facility supply
- Flow property / unit: Energy / kWh
- Amount rule: Use a dedicated meter or a documented causal share of the reconciled facility energy balance for this exact utility.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_energy_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Corrugated paperboard box (packaging_corrugated_box)
Corrugated paperboard box enters the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Corrugated paperboard box
- Flow property / unit: Mass / kg
- Amount rule: Calculate issued units multiplied by verified unit mass, adjusted for returns, closing stock and separately recorded scrap for this exact material.
- Value mode: Calculated value (
calculated_value) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging_inventory - Sources:
eu-pef-method-2021
High-density polyethylene crate (packaging_hdpe_crate)
High-density polyethylene crate enters the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: High-density polyethylene crate
- Flow property / unit: Mass / kg
- Amount rule: Calculate issued units multiplied by verified unit mass, adjusted for returns, closing stock and separately recorded scrap for this exact material.
- Value mode: Calculated value (
calculated_value) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging_inventory - Sources:
eu-pef-method-2021
Low-density polyethylene bag (packaging_ldpe_bag)
Low-density polyethylene bag enters the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Low-density polyethylene bag
- Flow property / unit: Mass / kg
- Amount rule: Calculate issued units multiplied by verified unit mass, adjusted for returns, closing stock and separately recorded scrap for this exact material.
- Value mode: Calculated value (
calculated_value) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging_inventory - Sources:
eu-pef-method-2021
Low-density polyethylene packaging film (packaging_ldpe_film)
Low-density polyethylene packaging film enters the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Low-density polyethylene packaging film
- Flow property / unit: Mass / kg
- Amount rule: Calculate issued units multiplied by verified unit mass, adjusted for returns, closing stock and separately recorded scrap for this exact material.
- Value mode: Calculated value (
calculated_value) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging_inventory - Sources:
eu-pef-method-2021
Polyamide packaging film (packaging_polyamide_film)
Polyamide packaging film enters the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Polyamide packaging film
- Flow property / unit: Mass / kg
- Amount rule: Calculate issued units multiplied by verified unit mass, adjusted for returns, closing stock and separately recorded scrap for this exact material.
- Value mode: Calculated value (
calculated_value) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging_inventory - Sources:
eu-pef-method-2021
Expanded polystyrene insulated box (packaging_eps_box)
Expanded polystyrene insulated box enters the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Expanded polystyrene insulated box
- Flow property / unit: Mass / kg
- Amount rule: Calculate issued units multiplied by verified unit mass, adjusted for returns, closing stock and separately recorded scrap for this exact material.
- Value mode: Calculated value (
calculated_value) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging_inventory - Sources:
eu-pef-method-2021
Polypropylene packaging strap (packaging_pp_strap)
Polypropylene packaging strap enters the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Polypropylene packaging strap
- Flow property / unit: Mass / kg
- Amount rule: Calculate issued units multiplied by verified unit mass, adjusted for returns, closing stock and separately recorded scrap for this exact material.
- Value mode: Calculated value (
calculated_value) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging_inventory - Sources:
eu-pef-method-2021
Paper label (packaging_paper_label)
Paper label enters the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Paper label
- Flow property / unit: Mass / kg
- Amount rule: Calculate issued units multiplied by verified unit mass, adjusted for returns, closing stock and separately recorded scrap for this exact material.
- Value mode: Calculated value (
calculated_value) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging_inventory - Sources:
eu-pef-method-2021
Silicone-coated release paper (packaging_release_paper)
Silicone-coated release paper enters the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Silicone-coated release paper
- Flow property / unit: Mass / kg
- Amount rule: Calculate issued units multiplied by verified unit mass, adjusted for returns, closing stock and separately recorded scrap for this exact material.
- Value mode: Calculated value (
calculated_value) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging_inventory - Sources:
eu-pef-method-2021
Wood pallet (packaging_wood_pallet)
Wood pallet enters the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Wood pallet
- Flow property / unit: Mass / kg
- Amount rule: Calculate issued units multiplied by verified unit mass, adjusted for returns, closing stock and separately recorded scrap for this exact material.
- Value mode: Calculated value (
calculated_value) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging_inventory - Sources:
eu-pef-method-2021
Aluminium closure clip (packaging_aluminium_clip)
Aluminium closure clip enters the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Aluminium closure clip
- Flow property / unit: Mass / kg
- Amount rule: Calculate issued units multiplied by verified unit mass, adjusted for returns, closing stock and separately recorded scrap for this exact material.
- Value mode: Calculated value (
calculated_value) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging_inventory - Sources:
eu-pef-method-2021
Carbon dioxide, food grade (packaging_carbon_dioxide)
Carbon dioxide, food grade enters the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Carbon dioxide, food grade
- Flow property / unit: Mass / kg
- Amount rule: Use purchase, opening-stock, issue, return and closing-stock records for this exact material.
- Value mode: Foreground record (
foreground_record) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_material_inventory - Sources:
eu-pef-method-2021
Nitrogen, food grade (packaging_nitrogen)
Nitrogen, food grade enters the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Nitrogen, food grade
- Flow property / unit: Mass / kg
- Amount rule: Use purchase, opening-stock, issue, return and closing-stock records for this exact material.
- Value mode: Foreground record (
foreground_record) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_material_inventory - Sources:
eu-pef-method-2021
Waste flows
No direct exchanges of this type are expected; record any exception as a separate atomic card.
Elementary flows
No direct exchanges of this type are expected; record any exception as a separate atomic card.
Outputs
Product flows
Meat of guinea fowl, frozen (reference_frozen_guinea_fowl_meat)
Meat of guinea fowl, frozen leaves the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified product exchange. This is the only UUID-bearing inventory row and the sole quantitative reference.
- Selected flow: Meat of guinea fowl, frozen
4671befd-6e3d-446b-a29e-d8db90e539ef - Flow property / unit: Mass
93a60a56-a3c8-11da-a746-0800200b9a66/ kg93a60a57-a4c8-11da-a746-0800200c9a66 - Amount rule: Fixed at 1 kg net conforming frozen guinea fowl meat; exclude packaging, retained gas, free ice and pallet mass.
- Value mode: Fixed value (
fixed_value) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Identity reference (
identity_reference) - Collection protocol:
cp_product_release - Sources:
Waste flows
Off-specification packaged frozen guinea fowl meat (offspec_packaged_frozen_meat_waste)
Off-specification packaged frozen guinea fowl meat leaves the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified waste exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Off-specification packaged frozen guinea fowl meat
- Flow property / unit: Mass / kg
- Amount rule: Use weighed container, dispatch, treatment and destination records for this exact stream.
- Value mode: Foreground record (
foreground_record) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_waste_byproduct_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Waste corrugated paperboard box (waste_corrugated_box)
Waste corrugated paperboard box leaves the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified waste exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Waste corrugated paperboard box
- Flow property / unit: Mass / kg
- Amount rule: Calculate issued units multiplied by verified unit mass, adjusted for returns, closing stock and separately recorded scrap for this exact material.
- Value mode: Calculated value (
calculated_value) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging_inventory - Sources:
eu-pef-method-2021
Waste high-density polyethylene crate (waste_hdpe_crate)
Waste high-density polyethylene crate leaves the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified waste exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Waste high-density polyethylene crate
- Flow property / unit: Mass / kg
- Amount rule: Calculate issued units multiplied by verified unit mass, adjusted for returns, closing stock and separately recorded scrap for this exact material.
- Value mode: Calculated value (
calculated_value) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging_inventory - Sources:
eu-pef-method-2021
Waste low-density polyethylene bag (waste_ldpe_bag)
Waste low-density polyethylene bag leaves the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified waste exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Waste low-density polyethylene bag
- Flow property / unit: Mass / kg
- Amount rule: Calculate issued units multiplied by verified unit mass, adjusted for returns, closing stock and separately recorded scrap for this exact material.
- Value mode: Calculated value (
calculated_value) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging_inventory - Sources:
eu-pef-method-2021
Waste low-density polyethylene packaging film (waste_ldpe_film)
Waste low-density polyethylene packaging film leaves the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified waste exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Waste low-density polyethylene packaging film
- Flow property / unit: Mass / kg
- Amount rule: Calculate issued units multiplied by verified unit mass, adjusted for returns, closing stock and separately recorded scrap for this exact material.
- Value mode: Calculated value (
calculated_value) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging_inventory - Sources:
eu-pef-method-2021
Waste polyamide packaging film (waste_polyamide_film)
Waste polyamide packaging film leaves the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified waste exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Waste polyamide packaging film
- Flow property / unit: Mass / kg
- Amount rule: Calculate issued units multiplied by verified unit mass, adjusted for returns, closing stock and separately recorded scrap for this exact material.
- Value mode: Calculated value (
calculated_value) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging_inventory - Sources:
eu-pef-method-2021
Waste expanded polystyrene insulated box (waste_eps_box)
Waste expanded polystyrene insulated box leaves the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified waste exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Waste expanded polystyrene insulated box
- Flow property / unit: Mass / kg
- Amount rule: Calculate issued units multiplied by verified unit mass, adjusted for returns, closing stock and separately recorded scrap for this exact material.
- Value mode: Calculated value (
calculated_value) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging_inventory - Sources:
eu-pef-method-2021
Waste polypropylene packaging strap (waste_pp_strap)
Waste polypropylene packaging strap leaves the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified waste exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Waste polypropylene packaging strap
- Flow property / unit: Mass / kg
- Amount rule: Calculate issued units multiplied by verified unit mass, adjusted for returns, closing stock and separately recorded scrap for this exact material.
- Value mode: Calculated value (
calculated_value) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging_inventory - Sources:
eu-pef-method-2021
Waste paper label (waste_paper_label)
Waste paper label leaves the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified waste exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Waste paper label
- Flow property / unit: Mass / kg
- Amount rule: Calculate issued units multiplied by verified unit mass, adjusted for returns, closing stock and separately recorded scrap for this exact material.
- Value mode: Calculated value (
calculated_value) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging_inventory - Sources:
eu-pef-method-2021
Waste silicone-coated release paper (waste_release_paper)
Waste silicone-coated release paper leaves the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified waste exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Waste silicone-coated release paper
- Flow property / unit: Mass / kg
- Amount rule: Calculate issued units multiplied by verified unit mass, adjusted for returns, closing stock and separately recorded scrap for this exact material.
- Value mode: Calculated value (
calculated_value) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging_inventory - Sources:
eu-pef-method-2021
Waste wood pallet (waste_wood_pallet)
Waste wood pallet leaves the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified waste exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Waste wood pallet
- Flow property / unit: Mass / kg
- Amount rule: Calculate issued units multiplied by verified unit mass, adjusted for returns, closing stock and separately recorded scrap for this exact material.
- Value mode: Calculated value (
calculated_value) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging_inventory - Sources:
eu-pef-method-2021
Waste aluminium closure clip (waste_aluminium_clip)
Waste aluminium closure clip leaves the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary as one separately quantified waste exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Waste aluminium closure clip
- Flow property / unit: Mass / kg
- Amount rule: Calculate issued units multiplied by verified unit mass, adjusted for returns, closing stock and separately recorded scrap for this exact material.
- Value mode: Calculated value (
calculated_value) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging_inventory - Sources:
eu-pef-method-2021
Elementary flows
Carbon dioxide, fossil, to air (packaging_carbon_dioxide_air)
Carbon dioxide, fossil, to air crosses from the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary to the environment as one separately quantified elementary exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Carbon dioxide, fossil, to air
- Flow property / unit: Mass / kg
- Amount rule: Use direct monitoring or a documented calculation from collected activity, composition, service and loss records for this exact release.
- Value mode: Calculated value (
calculated_value) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_air_emissions - Sources:
eu-pef-method-2021
Nitrogen, to air (packaging_nitrogen_air)
Nitrogen, to air crosses from the Frozen-product packaging, labelling, palletising, frozen storage and factory-gate dispatch boundary to the environment as one separately quantified elementary exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Nitrogen, to air
- Flow property / unit: Mass / kg
- Amount rule: Use direct monitoring or a documented calculation from collected activity, composition, service and loss records for this exact release.
- Value mode: Calculated value (
calculated_value) - Specificity: Product-specific (
product_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_air_emissions - Sources:
eu-pef-method-2021
Process: Cleaning, disinfection and wastewater management (sanitation_wastewater_management)
Inputs
Product flows
Process water (sanitation_process_water)
Process water enters the Cleaning, disinfection and wastewater management boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Process water
- Flow property / unit: Volume / m3
- Amount rule: Use a dedicated water meter or a documented process water balance for this exact stream.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_water_balance - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Electricity, facility supply (sanitation_electricity)
Electricity, facility supply enters the Cleaning, disinfection and wastewater management boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Electricity, facility supply
- Flow property / unit: Energy / kWh
- Amount rule: Use a dedicated meter or a documented causal share of the reconciled facility energy balance for this exact utility.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_energy_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Hot water (sanitation_hot_water)
Hot water enters the Cleaning, disinfection and wastewater management boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Hot water
- Flow property / unit: Energy / MJ
- Amount rule: Use a dedicated meter or a documented causal share of the reconciled facility energy balance for this exact utility.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_energy_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Steam (sanitation_steam)
Steam enters the Cleaning, disinfection and wastewater management boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Steam
- Flow property / unit: Energy / MJ
- Amount rule: Use a dedicated meter or a documented causal share of the reconciled facility energy balance for this exact utility.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_energy_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Sodium hydroxide (sanitation_sodium_hydroxide)
Sodium hydroxide enters the Cleaning, disinfection and wastewater management boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Sodium hydroxide
- Flow property / unit: Mass / kg
- Amount rule: Use purchase, issue, solution-concentration and stock records to calculate the pure-substance-equivalent amount for this exact chemical.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_chemical_inventory - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Nitric acid (sanitation_nitric_acid)
Nitric acid enters the Cleaning, disinfection and wastewater management boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Nitric acid
- Flow property / unit: Mass / kg
- Amount rule: Use purchase, issue, solution-concentration and stock records to calculate the pure-substance-equivalent amount for this exact chemical.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_chemical_inventory - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Sodium hypochlorite (sanitation_sodium_hypochlorite)
Sodium hypochlorite enters the Cleaning, disinfection and wastewater management boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Sodium hypochlorite
- Flow property / unit: Mass / kg
- Amount rule: Use purchase, issue, solution-concentration and stock records to calculate the pure-substance-equivalent amount for this exact chemical.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_chemical_inventory - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Peracetic acid (sanitation_peracetic_acid)
Peracetic acid enters the Cleaning, disinfection and wastewater management boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Peracetic acid
- Flow property / unit: Mass / kg
- Amount rule: Use purchase, issue, solution-concentration and stock records to calculate the pure-substance-equivalent amount for this exact chemical.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_chemical_inventory - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Hydrogen peroxide (sanitation_hydrogen_peroxide)
Hydrogen peroxide enters the Cleaning, disinfection and wastewater management boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Hydrogen peroxide
- Flow property / unit: Mass / kg
- Amount rule: Use purchase, issue, solution-concentration and stock records to calculate the pure-substance-equivalent amount for this exact chemical.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_chemical_inventory - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Benzalkonium chloride (sanitation_benzalkonium_chloride)
Benzalkonium chloride enters the Cleaning, disinfection and wastewater management boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Benzalkonium chloride
- Flow property / unit: Mass / kg
- Amount rule: Use purchase, issue, solution-concentration and stock records to calculate the pure-substance-equivalent amount for this exact chemical.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_chemical_inventory - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Sodium carbonate (sanitation_sodium_carbonate)
Sodium carbonate enters the Cleaning, disinfection and wastewater management boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Sodium carbonate
- Flow property / unit: Mass / kg
- Amount rule: Use purchase, issue, solution-concentration and stock records to calculate the pure-substance-equivalent amount for this exact chemical.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_chemical_inventory - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Ferric chloride (wastewater_ferric_chloride)
Ferric chloride enters the Cleaning, disinfection and wastewater management boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Ferric chloride
- Flow property / unit: Mass / kg
- Amount rule: Use purchase, issue, solution-concentration and stock records to calculate the pure-substance-equivalent amount for this exact chemical.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_chemical_inventory - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Calcium hydroxide (wastewater_calcium_hydroxide)
Calcium hydroxide enters the Cleaning, disinfection and wastewater management boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Calcium hydroxide
- Flow property / unit: Mass / kg
- Amount rule: Use purchase, issue, solution-concentration and stock records to calculate the pure-substance-equivalent amount for this exact chemical.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_chemical_inventory - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Anionic polyacrylamide (wastewater_anionic_polyacrylamide)
Anionic polyacrylamide enters the Cleaning, disinfection and wastewater management boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Anionic polyacrylamide
- Flow property / unit: Mass / kg
- Amount rule: Use purchase, issue, solution-concentration and stock records to calculate the pure-substance-equivalent amount for this exact chemical.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_chemical_inventory - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Waste flows
Live-guinea-fowl reception wastewater (treatment_reception_wastewater)
Live-guinea-fowl reception wastewater enters the Cleaning, disinfection and wastewater management boundary as one separately quantified waste exchange for treatment. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Live-guinea-fowl reception wastewater
- Flow property / unit: Volume / m3
- Amount rule: Use matched flow-meter, transfer, treatment and destination records for this exact stream.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wastewater_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Guinea-fowl-slaughter wastewater (treatment_slaughter_wastewater)
Guinea-fowl-slaughter wastewater enters the Cleaning, disinfection and wastewater management boundary as one separately quantified waste exchange for treatment. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Guinea-fowl-slaughter wastewater
- Flow property / unit: Volume / m3
- Amount rule: Use matched flow-meter, transfer, treatment and destination records for this exact stream.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wastewater_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Guinea-fowl-meat cutting wastewater (treatment_cutting_wastewater)
Guinea-fowl-meat cutting wastewater enters the Cleaning, disinfection and wastewater management boundary as one separately quantified waste exchange for treatment. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Guinea-fowl-meat cutting wastewater
- Flow property / unit: Volume / m3
- Amount rule: Use matched flow-meter, transfer, treatment and destination records for this exact stream.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wastewater_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Freezer defrost wastewater (treatment_freezer_defrost_wastewater)
Freezer defrost wastewater enters the Cleaning, disinfection and wastewater management boundary as one separately quantified waste exchange for treatment. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Freezer defrost wastewater
- Flow property / unit: Volume / m3
- Amount rule: Use matched flow-meter, transfer, treatment and destination records for this exact stream.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wastewater_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Elementary flows
No direct exchanges of this type are expected; record any exception as a separate atomic card.
Outputs
Product flows
Treated process water (treated_process_water)
Treated process water leaves the Cleaning, disinfection and wastewater management boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Treated process water
- Flow property / unit: Volume / m3
- Amount rule: Use matched flow-meter, transfer, treatment and destination records for this exact stream.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wastewater_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Recovered biogas (recovered_biogas)
Recovered biogas leaves the Cleaning, disinfection and wastewater management boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Recovered biogas
- Flow property / unit: Energy / MJ
- Amount rule: Use matched flow-meter, transfer, treatment and destination records for this exact stream.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wastewater_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Waste flows
Guinea-fowl-meat processing wastewater (offsite_treatment_wastewater)
Guinea-fowl-meat processing wastewater leaves the Cleaning, disinfection and wastewater management boundary as one separately quantified waste exchange. Use only for net wastewater handed to an external treatment operator.
- Selected flow: Guinea-fowl-meat processing wastewater
- Flow property / unit: Volume / m3
- Amount rule: Use matched flow-meter, transfer, treatment and destination records for this exact stream.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wastewater_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Wastewater-treatment sludge (wastewater_treatment_sludge)
Wastewater-treatment sludge leaves the Cleaning, disinfection and wastewater management boundary as one separately quantified waste exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Wastewater-treatment sludge
- Flow property / unit: Mass / kg
- Amount rule: Use weighed container, dispatch, treatment and destination records for this exact stream.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_waste_byproduct_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Wastewater-screened solids (wastewater_screened_solids)
Wastewater-screened solids leaves the Cleaning, disinfection and wastewater management boundary as one separately quantified waste exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Wastewater-screened solids
- Flow property / unit: Mass / kg
- Amount rule: Use weighed container, dispatch, treatment and destination records for this exact stream.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_waste_byproduct_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Dissolved-air-flotation grease sludge (wastewater_daf_grease_sludge)
Dissolved-air-flotation grease sludge leaves the Cleaning, disinfection and wastewater management boundary as one separately quantified waste exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Dissolved-air-flotation grease sludge
- Flow property / unit: Mass / kg
- Amount rule: Use weighed container, dispatch, treatment and destination records for this exact stream.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_waste_byproduct_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Elementary flows
Biochemical oxygen demand BOD5, to water (effluent_bod5_water)
Biochemical oxygen demand BOD5, to water crosses from the Cleaning, disinfection and wastewater management boundary to the environment as one separately quantified elementary exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Biochemical oxygen demand BOD5, to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate the discharged load from matched effluent-volume and laboratory-concentration records for this exact parameter.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wastewater_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Chemical oxygen demand, to water (effluent_cod_water)
Chemical oxygen demand, to water crosses from the Cleaning, disinfection and wastewater management boundary to the environment as one separately quantified elementary exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Chemical oxygen demand, to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate the discharged load from matched effluent-volume and laboratory-concentration records for this exact parameter.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wastewater_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Suspended solids, to water (effluent_suspended_solids_water)
Suspended solids, to water crosses from the Cleaning, disinfection and wastewater management boundary to the environment as one separately quantified elementary exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Suspended solids, to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate the discharged load from matched effluent-volume and laboratory-concentration records for this exact parameter.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wastewater_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Nitrogen total, to water (effluent_total_nitrogen_water)
Nitrogen total, to water crosses from the Cleaning, disinfection and wastewater management boundary to the environment as one separately quantified elementary exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Nitrogen total, to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate the discharged load from matched effluent-volume and laboratory-concentration records for this exact parameter.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wastewater_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Phosphorus total, to water (effluent_total_phosphorus_water)
Phosphorus total, to water crosses from the Cleaning, disinfection and wastewater management boundary to the environment as one separately quantified elementary exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Phosphorus total, to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate the discharged load from matched effluent-volume and laboratory-concentration records for this exact parameter.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wastewater_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Chloride, to water (effluent_chloride_water)
Chloride, to water crosses from the Cleaning, disinfection and wastewater management boundary to the environment as one separately quantified elementary exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Chloride, to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate the discharged load from matched effluent-volume and laboratory-concentration records for this exact parameter.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wastewater_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Methane, to air (wastewater_methane_air)
Methane, to air crosses from the Cleaning, disinfection and wastewater management boundary to the environment as one separately quantified elementary exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Methane, to air
- Flow property / unit: Mass / kg
- Amount rule: Use direct monitoring or a documented calculation from collected activity, composition, service and loss records for this exact release.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_air_emissions - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Ammonia, to air (wastewater_ammonia_air)
Ammonia, to air crosses from the Cleaning, disinfection and wastewater management boundary to the environment as one separately quantified elementary exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Ammonia, to air
- Flow property / unit: Mass / kg
- Amount rule: Use direct monitoring or a documented calculation from collected activity, composition, service and loss records for this exact release.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_air_emissions - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Process: On-site fuel combustion and utility generation (onsite_energy_generation)
Inputs
Product flows
Process water (boiler_process_water)
Process water enters the On-site fuel combustion and utility generation boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Process water
- Flow property / unit: Volume / m3
- Amount rule: Use a dedicated water meter or a documented process water balance for this exact stream.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_water_balance - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Electricity, facility supply (onsite_auxiliary_electricity)
Electricity, facility supply enters the On-site fuel combustion and utility generation boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Electricity, facility supply
- Flow property / unit: Energy / kWh
- Amount rule: Use a dedicated meter or a documented causal share of the reconciled facility energy balance for this exact utility.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_energy_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Natural gas (onsite_natural_gas)
Natural gas enters the On-site fuel combustion and utility generation boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Natural gas
- Flow property / unit: Energy / MJ
- Amount rule: Use calibrated fuel meters or purchase, tank, issue and closing-stock records for this exact fuel on a declared energy basis.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_fuel_inventory - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Diesel fuel (onsite_diesel)
Diesel fuel enters the On-site fuel combustion and utility generation boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Diesel fuel
- Flow property / unit: Energy / MJ
- Amount rule: Use calibrated fuel meters or purchase, tank, issue and closing-stock records for this exact fuel on a declared energy basis.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_fuel_inventory - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Liquefied petroleum gas (onsite_lpg)
Liquefied petroleum gas enters the On-site fuel combustion and utility generation boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Liquefied petroleum gas
- Flow property / unit: Energy / MJ
- Amount rule: Use calibrated fuel meters or purchase, tank, issue and closing-stock records for this exact fuel on a declared energy basis.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_fuel_inventory - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Recovered biogas (onsite_recovered_biogas)
Recovered biogas enters the On-site fuel combustion and utility generation boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Recovered biogas
- Flow property / unit: Energy / MJ
- Amount rule: Use calibrated fuel meters or purchase, tank, issue and closing-stock records for this exact fuel on a declared energy basis.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_fuel_inventory - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Sodium hydroxide (boiler_sodium_hydroxide)
Sodium hydroxide enters the On-site fuel combustion and utility generation boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Sodium hydroxide
- Flow property / unit: Mass / kg
- Amount rule: Use purchase, issue, solution-concentration and stock records to calculate the pure-substance-equivalent amount for this exact chemical.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_chemical_inventory - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Trisodium phosphate (boiler_trisodium_phosphate)
Trisodium phosphate enters the On-site fuel combustion and utility generation boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Trisodium phosphate
- Flow property / unit: Mass / kg
- Amount rule: Use purchase, issue, solution-concentration and stock records to calculate the pure-substance-equivalent amount for this exact chemical.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_chemical_inventory - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Waste flows
No direct exchanges of this type are expected; record any exception as a separate atomic card.
Elementary flows
No direct exchanges of this type are expected; record any exception as a separate atomic card.
Outputs
Product flows
Steam (onsite_steam_output)
Steam leaves the On-site fuel combustion and utility generation boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Steam
- Flow property / unit: Energy / MJ
- Amount rule: Use a dedicated meter or a documented causal share of the reconciled facility energy balance for this exact utility.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_energy_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Hot water (onsite_hot_water_output)
Hot water leaves the On-site fuel combustion and utility generation boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Hot water
- Flow property / unit: Energy / MJ
- Amount rule: Use a dedicated meter or a documented causal share of the reconciled facility energy balance for this exact utility.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_energy_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Electricity (onsite_electricity_output)
Electricity leaves the On-site fuel combustion and utility generation boundary as one separately quantified product exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Electricity
- Flow property / unit: Energy / kWh
- Amount rule: Use a dedicated meter or a documented causal share of the reconciled facility energy balance for this exact utility.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_energy_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Waste flows
Boiler blowdown wastewater (boiler_blowdown_wastewater)
Boiler blowdown wastewater leaves the On-site fuel combustion and utility generation boundary as one separately quantified waste exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Boiler blowdown wastewater
- Flow property / unit: Volume / m3
- Amount rule: Use matched flow-meter, transfer, treatment and destination records for this exact stream.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wastewater_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Spent lubricating oil (spent_lubricating_oil_waste)
Spent lubricating oil leaves the On-site fuel combustion and utility generation boundary as one separately quantified waste exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Spent lubricating oil
- Flow property / unit: Mass / kg
- Amount rule: Use weighed container, dispatch, treatment and destination records for this exact stream.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_waste_byproduct_records - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Elementary flows
Carbon dioxide, fossil, to air (onsite_carbon_dioxide_fossil_air)
Carbon dioxide, fossil, to air crosses from the On-site fuel combustion and utility generation boundary to the environment as one separately quantified elementary exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Carbon dioxide, fossil, to air
- Flow property / unit: Mass / kg
- Amount rule: Use direct monitoring or a documented calculation from collected activity, composition, service and loss records for this exact release.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_air_emissions - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Carbon dioxide, biogenic, to air (onsite_carbon_dioxide_biogenic_air)
Carbon dioxide, biogenic, to air crosses from the On-site fuel combustion and utility generation boundary to the environment as one separately quantified elementary exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Carbon dioxide, biogenic, to air
- Flow property / unit: Mass / kg
- Amount rule: Use direct monitoring or a documented calculation from collected activity, composition, service and loss records for this exact release.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_air_emissions - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Nitrogen oxides expressed as nitrogen dioxide, to air (onsite_nitrogen_oxides_air)
Nitrogen oxides expressed as nitrogen dioxide, to air crosses from the On-site fuel combustion and utility generation boundary to the environment as one separately quantified elementary exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Nitrogen oxides expressed as nitrogen dioxide, to air
- Flow property / unit: Mass / kg
- Amount rule: Use direct monitoring or a documented calculation from collected activity, composition, service and loss records for this exact release.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_air_emissions - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Sulfur oxides expressed as sulfur dioxide, to air (onsite_sulfur_oxides_air)
Sulfur oxides expressed as sulfur dioxide, to air crosses from the On-site fuel combustion and utility generation boundary to the environment as one separately quantified elementary exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Sulfur oxides expressed as sulfur dioxide, to air
- Flow property / unit: Mass / kg
- Amount rule: Use direct monitoring or a documented calculation from collected activity, composition, service and loss records for this exact release.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_air_emissions - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Carbon monoxide, to air (onsite_carbon_monoxide_air)
Carbon monoxide, to air crosses from the On-site fuel combustion and utility generation boundary to the environment as one separately quantified elementary exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Carbon monoxide, to air
- Flow property / unit: Mass / kg
- Amount rule: Use direct monitoring or a documented calculation from collected activity, composition, service and loss records for this exact release.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_air_emissions - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
Particulate matter PM10, to air (onsite_pm10_air)
Particulate matter PM10, to air crosses from the On-site fuel combustion and utility generation boundary to the environment as one separately quantified elementary exchange. Keep its identity, quantity, source or destination separate from every alternative exchange.
- Selected flow: Particulate matter PM10, to air
- Flow property / unit: Mass / kg
- Amount rule: Use direct monitoring or a documented calculation from collected activity, composition, service and loss records for this exact release.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg net conforming meat of guinea fowl, frozen at factory gate
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_air_emissions - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-method-2021
7. Allocation and Co-product Handling
| rule_id | Applies to | Rule | Sources |
|---|---|---|---|
alloc_subdivision_first | slaughter, dressing and cutting | Use subdivision and direct process measurement before allocation wherever separate operations and records are available. | eu-pef-method-2021 |
alloc_co_product_status | feathers, blood, organs, fat, skin, bones, heads and feet | Determine product or waste status at the actual hand-off point and use only the matching product or waste row; never count the same physical mass in both. | ec-jrc-sa-bref-jrc135916; eu-pef-method-2021 |
alloc_physical_relation | unavoidable joint co-products | When subdivision is not possible, use an evidence-backed physical causal relation only when it reflects how inputs and emissions change with co-product production. | eu-pef-method-2021 |
alloc_economic_fallback | remaining joint co-products | If no defensible physical relation exists, use a documented economic allocation consistent with the applicable study programme and reporting period; do not invent a default factor. | eu-pef-method-2021 |
alloc_waste_no_credit | waste streams | Assign treatment burdens to the declared hand-off without an avoided-product credit unless the applicable downstream model explicitly requires and documents that scenario. | eu-pef-method-2021 |
alloc_internal_recovery | treated water, biogas, steam, hot water and electricity | Treat internal recovery as a linked transfer; do not allocate or credit the same recovered quantity twice. | eu-pef-method-2021 |
8. Foreground Data Collection, Calculation, and Quality Rules
Data Collection Protocols
| protocol_id | process_id | flow_role | record_type | raw_fields | collection_method | unit | frequency | temporal_coverage | site_scope | aggregation_rule | quality_evidence |
|---|---|---|---|---|---|---|---|---|---|---|---|
cp_live_bird_mass | live_guinea_fowl_reception | live-bird receipt and disposition | weighbridge and lot records | lot_id; supplier; origin; arrival_time; gross_mass; tare_mass; accepted_mass; rejected_mass; dead_on_arrival_mass | calibrated weighbridge or batch scale reconciled to receiving records | kg | each lot | full reporting period | all represented receipts | sum by lot and reconcile accepted plus rejected dispositions | calibration record; signed receipt; disposition log |
cp_process_mass_balance | all slaughter and meat processes | carcasses, meat, organs and intermediates | production and scale records | batch_id; input_mass; output_mass; product_state; trim_mass; bone_mass; organ_mass; inventory_change | calibrated scales and line-production records | kg | each batch or shift | full reporting period | all represented lines | reconcile inputs, outputs, inventory changes and documented losses before normalization | calibration; batch sheet; balance exception log |
cp_energy_records | all processes | electricity, steam and hot water | meter and utility records | meter_id; timestamp; opening_reading; closing_reading; energy_carrier; generated_amount; transferred_amount | dedicated meters or documented causal allocation from reconciled site meters | kWh; MJ | continuous or each billing period | full reporting period | all represented equipment and utilities | aggregate exact carriers separately and reconcile imports, generation and internal transfers | meter calibration; invoice; reconciliation |
cp_fuel_inventory | onsite_energy_generation | individual fuels | fuel meter, invoice and tank records | fuel_identity; quantity; unit; energy_basis; opening_stock; purchases; issues; closing_stock | meter or stock reconciliation for each fuel | MJ | each delivery and reporting period | full reporting period | all on-site combustion units | calculate consumption separately by fuel and declared energy basis | invoice; tank calibration; fuel specification |
cp_water_balance | all processes | process, pre-chilling and utility water | water-meter records | meter_id; source; destination; opening_reading; closing_reading; recirculation; discharge | dedicated meters and documented water balance | m3 | continuous or daily | full reporting period | all represented water circuits | separate external make-up, internal reuse and discharged water | meter calibration; balance reconciliation |
cp_material_inventory | applicable processes | named processing materials, ice, gases and coolants | purchase and stock records | material_identity; concentration; opening_stock; purchases; issues; returns; closing_stock | material-specific stock reconciliation | kg | each issue and reporting period | full reporting period | all represented materials | calculate each exact material separately | invoice; specification; inventory record |
cp_chemical_inventory | sanitation and utilities | named chemicals | chemical issue and concentration records | chemical_identity; formulation; active_fraction; opening_stock; purchases; issues; closing_stock | material balance converted to pure-substance-equivalent mass | kg | each issue and reporting period | full reporting period | all represented chemical stores and dosing points | no aggregation across chemical identities | safety data sheet; concentration test; stock reconciliation |
cp_refrigerant_balance | prechilling_freezing | each refrigerant and fugitive component | equipment and service records | equipment_id; refrigerant_identity; blend_composition; opening_stock; purchases; charge; recovery; returns; closing_stock; service_loss | reporting-period refrigerant mass balance | kg | each service event and reporting period | full reporting period | every represented refrigeration circuit | calculate each refrigerant input and each emitted component separately | service invoice; cylinder weights; composition specification |
cp_packaging_inventory | frozen_packaging_storage | each packaging material and scrap | bill of materials, issue and scrap records | material_identity; units_issued; unit_mass; returns; scrap_mass; reusable_cycles | item count multiplied by verified unit mass plus stock reconciliation | kg | each production batch and reporting period | full reporting period | every represented packaging line | calculate each material separately and exclude packaging from product net mass | supplier specification; scale check; issue record |
cp_product_release | freezing and frozen dispatch | conforming reference product | lot-release records | lot_id; net_mass; product_form; bone_status; skin_status; product_temperature; frozen_state; glazing_status; packaging_format; release_decision | calibrated final scale plus quality and temperature review | kg | each lot | full reporting period | all reference-product lots | sum released net product only; exclude nonconforming and non-product mass | calibration; temperature log; release certificate |
cp_waste_byproduct_records | all processes | individual co-products and wastes | weighed dispatch and treatment records | stream_identity; container_tare; gross_mass; net_mass; product_or_waste_status; destination; date | calibrated scale or documented container mass | kg | each transfer | full reporting period | every declared stream and destination | keep each physical stream and status separate | weigh ticket; consignment note; destination evidence |
cp_wastewater_records | sanitation_wastewater_management | wastewater, treatment outputs and water emissions | flow meter and laboratory records | stream_identity; volume; sample_time; concentration; parameter; treatment_route; sludge_mass; destination | matched flow measurement and representative sampling | m3; kg | continuous flow and risk-based sampling | full reporting period | every discharge and treatment route | calculate load as matched volume times concentration; reconcile sludge and off-site transfers | meter calibration; laboratory report; permit record |
cp_air_emissions | refrigeration, packaging, wastewater and energy | direct air emissions | monitoring, mass-balance and service records | emission_identity; source; activity; concentration; flow_rate; duration; composition; calculated_loss | direct monitoring or documented calculation from collected source records | kg | continuous, campaign or service event as applicable | full reporting period | every direct emission source | calculate and report each elementary flow separately | monitoring report; service record; calculation worksheet |
Raw downloads
These files are byte-identical to the canonical files for this revision in the repository.
Complete field inspector
Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.