Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:36972 · narrower

Source

7. Allocation and Co-product Handling

rule_idApplies toRulesource_ids
allocation_scopeall inventory rowsThis method uses attributional allocation only where the study situation requires allocation. Establish that scope first; industrial manufacturing sources do not authorize a consequential substitution or automatic recycling credit. Respect applicable ILCD situation/recycling provisions when a different question is asked.jrc-ilcd-2010
allocation_exclusiveall inventory rowsFirst subdivide actual distinguishable stages/lines or use evidenced virtual subdivision. Assign each whole formulation, dedicated machine meter, test, failure, cleanup, package and FG service directly to its causing lot/product when possible. Retain burden-bearing stock transfers and shared idle loads; no total-output shortcut before exclusive attribution.jrc-ilcd-2010
allocation_causalityall inventory rowsFor each still-shared exchange independently identify the determining physical cause and actual measured driver, e.g. heater duty with temperature/time/configuration, cooling duty with measured flow/enthalpy, or handling with actual operations. Mass/count alone is not universal causality. Validate each driver and allocation total/uncertainty; different exchanges may need different causal drivers.jrc-ilcd-2010
allocation_residualall inventory rowsOnly the genuine residual lacking a determining physical assignment uses relative market value of actual cofunctions at the common process exit/entry gate in their real state and period. Derive same-gate values transparently by removing later transport/conditioning/packaging costs where necessary; record quantity, currency, date and sensitivity. Unknown causal/value evidence holds that dataset incomplete; no fixed ratio or free choice between physical/economic keys.jrc-ilcd-2010
allocation_returnsall packaging rows; fg_out; fg_return; waste_fgPhysical custody remains unchanged by burden allocation. Internal reuse carries inherited burden once; external waste/recovery follows actual treatment/ownership and applicable recycling model. No automatic negative flow, avoided virgin credit or erasure of old cap production from a return, retest or lost lot.jrc-ilcd-2010
asset_manufacture_conservationexisting capital/reusable manufacture attributionWithin the applicable allocation decision context, original manufacture burden attributed across uses of actual capital equipment or reusable articles already included in foreground production, packaging or observed services uses one persistent same-asset ledger across all crops, products, cohorts, manufacturing/postrelease services, owners and observation periods. D is its supported whole installed service: all realized historical service plus supported remaining service in the same units as actual beneficiary use u; D must be finite and positive. Period capacity, remaining-only capacity, the physical asset/article mass alone, or current-period product Q alone is not D; supported whole-service throughput in mass units may be used when it demonstrates the causal service and matches u. This does not amortize the manufactured reference product over downstream life or change its declared reference gate/Q. The fractions u/D and all previously assigned manufacture shares together must never exceed 1. Changes of window, custody, provider or repair never restart the original manufacture balance. Replacements have distinct identities and only their real new manufacture vectors; actual repair and treatment increments remain separately accounted. Revised capacity evidence requires transparent reconciliation of prior shares and sensitivity, not a fresh ledger. Keep full physical mass and stock movements independent of burden shares. Unknown D, prior shares or beneficiary coverage requires review and no final manufacture-attributed amount; no assumed lifetime, utilization, zero or arbitrary division is permitted. For each existing collection protocol that attributes manufacture of included production, packaging or observed-service assets across uses in this route (excluding amortization of the manufactured reference product itself), additionally retain a durable asset identity, its measured full physical mass and acquisition/installation/retirement stock history, original manufacture burden vector, all historical and current beneficiaries, matched-unit service readings, the evidenced whole installed-service denominator D, supported remaining-service basis and uncertainty, prior assigned shares and remaining original manufacture balance. Carry the ledger across reporting windows and custody/provider changes. Collect actual repair, replacement, recovery and treatment separately; these records do not normalize physical movements or create an additional asset purchase. These are added fields and conservation obligations for the existing applicable protocols, not a new assumed capital inventory.

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

For each existing collection protocol that attributes manufacture of included production, packaging or observed-service assets across uses in this route (excluding amortization of the manufactured reference product itself), additionally retain a durable asset identity, its measured full physical mass and acquisition/installation/retirement stock history, original manufacture burden vector, all historical and current beneficiaries, matched-unit service readings, the evidenced whole installed-service denominator D, supported remaining-service basis and uncertainty, prior assigned shares and remaining original manufacture balance. Carry the ledger across reporting windows and custody/provider changes. Collect actual repair, replacement, recovery and treatment separately; these records do not normalize physical movements or create an additional asset purchase. These are added fields and conservation obligations for the existing applicable protocols, not a new assumed capital inventory.

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_materialcap_productionWhole preparations and actual auxiliariespurchase/stock/issuelot; supplied preparation; composition assay; measured receipts; opening/closing raw and WIP; equipment location; losses; upstream linksReconcile calibrated weighing, invoices, issue/return and actual A/B dosing/mixing logs; assays are child accounts only. Retain undivided raw entries by lot and state; attribution and stock-vector reconciliation precede report_once.kgeach lot/event and meter intervalfull declared period including zero-output and historical opening lotsactual site equipment and lotper 1 kg reference flowScale calibration and supplier formulation/compatibility documents
cp_energycap_productionManufacturing electricitymeterequipment; meter; raw kWh; interval; warmup idle failure cleanup rework; cause driver; voltage geography providerSubmeter actual mould heaters/drives/cooling/air/vacuum/postcure and shared services; retain raw intervals and exclude duplicate provider services. Retain undivided raw entries by lot and state; attribution and stock-vector reconciliation precede report_once.kWheach lot/event and meter intervalfull declared period including zero-output and historical opening lotsactual site equipment and lotper 1 kg reference flowMeter calibration and electrical supply-boundary evidence
cp_watercap_productionWater loops cleaning and external returnsmeter/sample/stockwater identity; original volume/mass/rate; interval; density; temperature pressure; loop opening/closing; inlet return effluent evaporation; enthalpyMeasure each boundary separately; independently sample composition/phase and loop stock; verify supplier energy/water agreement and calibrations. Retain undivided raw entries by lot and state; attribution and stock-vector reconciliation precede report_once.original uniteach lot/event and meter intervalfull declared period including zero-output and historical opening lotsactual site equipment and lotper 1 kg reference flowWater/state/effluent analyses and supplier agreement
cp_chargecap_productionHydraulic oil and R134a chargesstock/servicematerial; equipment; charge location; opening/closing; additions; recovery return; waste; leak; density/state; inherited vectorMeasure each actual charge and movement independently; preserve all inherited exchanges; reconcile without double counting raw/WIP. Retain undivided raw entries by lot and state; attribution and stock-vector reconciliation precede report_once.original uniteach lot/event and meter intervalfull declared period including zero-output and historical opening lotsactual site equipment and lotper 1 kg reference flowService/weighing logs and independent substance density
cp_aircap_productionActual gas intake and dischargemeter/speciationintake origin; purchased air; integrated volume or actual rate; interval; P T humidity; nitrogen oxygen argon CO2 composition; outlet; uptakeUse calibrated state-bound gas meters and independent composition/humidity; distinguish onsite resource and purchased carrier child accounts, no repeated time integration. Retain undivided raw entries by lot and state; attribution and stock-vector reconciliation precede report_once.original uniteach lot/event and meter intervalfull declared period including zero-output and historical opening lotsactual site equipment and lotper 1 kg reference flowGas-meter calibration and actual composition/state records
cp_speciescap_productionEach actual emission speciessample/fluxspecies CAS; compartment; raw concentration; actual integrated flow or rate; interval; detection limit; control; captured mass; uncertaintyMeasure actual species after controls with consistent wet/dry and state bases; collect independent input/retained/wastewater/residue chemistry and phase evidence. Retain undivided raw entries by lot and state; attribution and stock-vector reconciliation precede report_once.original uniteach lot/event and meter intervalfull declared period including zero-output and historical opening lotsactual site equipment and lotper 1 kg reference flowLaboratory chain calibration detection limits and destination records
cp_wastecap_productionEach real wasteweigh/manifestsingle waste identity; uncured/cured state; gross mass; dry solids; water; contamination; destination; lot vectorWeigh each actual material/outlet separately; reconcile collection/treatment handoff and retained contents; no aggregate waste/species substitution. Retain undivided raw entries by lot and state; attribution and stock-vector reconciliation precede report_once.kgeach lot/event and meter intervalfull declared period including zero-output and historical opening lotsactual site equipment and lotper 1 kg reference flowWaste manifests scale calibration and actual assays
cp_qualitycap_productionUnique new first-release capweigh/test/releaselot; configuration; cure/postcure logs; test methods/limits; net accepted kg; first-release IDs; reject test and WIP kgWeigh complete accepted caps with calibrated scale after declared conditioning excluding packaging; reconcile new unique release IDs and measured count if collected; retain all failures and destructive samples. Retain undivided raw entries by lot and state; attribution and stock-vector reconciliation precede report_once.kgeach lot/event and meter intervalfull declared period including zero-output and historical opening lotsactual site equipment and lotper 1 kg reference flowRelease authorization geometry/cure test and weighing records
cp_fgcap_productionFG stock and physical custodylot ledgerlot; original Q and numerator/vector; opening/closingFG; new release; gross outward; external return; reversal; disposal; service periodTrace actual lot custody and original denominator/history; reconcile physical movements and separately attribute incremental return work; no fabricated new production. Retain undivided raw entries by lot and state; attribution and stock-vector reconciliation precede report_once.kgeach lot/event and meter intervalfull declared period including zero-output and historical opening lotsactual site equipment and lotper 1 kg reference flowWarehouse dispatch return and historic burden records
cp_fg_energycap_productionActual FG service powermeter/driverlot; original denominator; service period; raw kWh; shared meter; actual causal driver; idle and return workSeparate service meters and actual lot drivers from manufacturing and from other cohorts; retain old-cohort numerator and denominator. Retain undivided raw entries by lot and state; attribution and stock-vector reconciliation precede report_once.kWheach lot/event and meter intervalfull declared period including zero-output and historical opening lotsactual site equipment and lotper 1 kg reference flowMeters service driver measurements and stock-cohort history
cp_packcap_productionEvery separate packaging articlearticle stock/custodyarticle composition; lot; tare; opening/closing empty attachedWIP attachedFG reusable; new purchase/receipt; return received; gross shipment; return sent; waste; contentCount and independently weigh actual article tare with real composition and complete directional custody; reuse does not alter measured gross outward mass. Retain undivided raw entries by lot and state; attribution and stock-vector reconciliation precede report_once.kgeach lot/event and meter intervalfull declared period including zero-output and historical opening lotsactual site equipment and lotper 1 kg reference flowSupplier packaging declarations tare weighing custody and waste records
cp_transportcap_productionActual road transporttriptrip; article and cap lot; actual payload including packaging; distance; loaded/return legs; provider boundaryMeasure trip mass and distance and check carrier records/provider boundary; retain distinct actual outbound/return service attribution. Retain undivided raw entries by lot and state; attribution and stock-vector reconciliation precede report_once.t.kmeach lot/event and meter intervalfull declared period including zero-output and historical opening lotsactual site equipment and lotper 1 kg reference flowWeighbridge trip and carrier records
cp_allocationcap_productionall inventory rowsallocation evidence ledgerexchange; cofunction; exclusive meter; virtual subdivision; determining causal hypothesis; measured driver; residual shared amount; common gate; actual state; contemporaneous quantity price currency date; downstream cost adjustment; uncertaintyCollect independent proof for each hierarchy step and each exchange. Preserve raw undivided allocations and stock/cohort vectors; do not normalize here. Unknown causality/value evidence keeps the actual dataset incomplete.each exchange original uniteach attribution period and configuration changesame complete operating and value periodactual shared process gateper 1 kg reference flowdedicated-meter proof; causal study; same-gate price evidence; full allocated-sum conservation

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
convert_rawall inventory rowsConvert calibrated raw values to the declared atomic numerator unit before attribution; integrate only actual rates once. Use independent material state/density/composition, never a screening property coefficient. Preserve original records and uncertainty.raw_value; raw_unit; interval; measured_state; density; compositionraw_numerator
quality_quantityreleased_capQ = sum of unique new first-accepted net complete-cap kg; exclude packaging and previously released lots. No delivery or reinspection count enters Q.cp_quality; accepted_lot_mass; first_release_idQjerry-swim-cap-production
stock_vectorsall inventory rowsBy each actual raw/WIP/loop/equipment lot conserve physical amount and every inherited exchange vector: opening plus real increments/transfers equals closing plus actual exits/consumption; preserve source cohort denominator and eliminate overlapping stock accounts.cp_material; cp_water; cp_charge; opening_vector; current_increment; closing_vectorattributed_lot_vector
exchange_attributionall inventory rowsExclusive/virtual subdivision precedes exchange-specific determining physical causality; only the genuine remaining shared residual uses same-period actual common-gate market values. Preserve Q=0 loads for explicit burden transfer/disclosure, not arbitrary future amortization.raw_numerator; attributed_lot_vector; causal_driver; residual_gate_valueA_ijrc-ilcd-2010
fg_cohortsfg_in; fg_return; fg_out; fg_power; waste_fgRetain original manufacturing A_i and original Q for old FG/returns; add only measured attributable incremental service numerator to the same cohort. Reconcile physical FG gate and original dispatch reversals independently; do not allocate old-cohort services onto unrelated current Q.cp_fg; cp_fg_energy; original_numerator; original_Q; actual_service_incrementcohort_A_i; cohort_Q
pack_balanceall packaging rowsApply the full boundary_pack equation to each whole physical article independently; keep all actual external directions at measured gross article mass and internal reuse cancelling only inside custody. Burden allocation cannot alter physical movement.cp_pack; article_stock; article_purchase; return_received; gross_outward; return_sent; article_wastearticle_balance
species_balanceall elementary rowsClose total mass/elements and independently measured actual species/phase balances, including carrier gas and separate external water/equipment stocks. Never fit multiple unknown species to one residual or convert COD/TVOC to a specific chemical.cp_species; cp_air; cp_water; cp_charge; independent_assaysspecies_balancewacker-silicone-processing
report_onceall inventory rowsq_i = A_i / Q, once for the identified new first-release cohort after raw conversion, attribution and inherited-vector reconciliation. For old cohorts use their own cohort_A_i and original cohort_Q in this same operation. Q=0 retains loads and produces no unit result. Reference output is 1 kg by definition; cards and aggregation only refer to this operation.A_i; Q; cohort_A_i; cohort_Qq_i
asset_manufacture_shareexisting capital/reusable manufacture attributionFor each included original asset manufacture vector B, f_current = u_current / D only after the persistent ledger verifies the supported whole installed-service denominator, all beneficiaries and prior assigned shares. Attribute f_current * B once to the actual beneficiary before the existing single reference normalization. Check prior_shares + all current/new beneficiary shares <= 1; carry the remaining original balance. Capacity revisions reconcile the historical ledger. Full physical asset/packaging mass and actual gross stocks/returns never receive f_current. Unknown D or history leaves the final attributed result unavailable, without suppressing actual repair/replacement/service burdens.asset_id; original_B; u_current; D; historical_beneficiaries; prior_shares; capacity_evidenceconserved attributed manufacture vector

Data Quality Requirements

requirement_idApplies toRequirementEvidence
dq_identityall inventory rowsMatch whole preparations/grades, complete native names/qualifiers/CAS/geography/type/all properties/reference units and actual provider. Empty auxiliary UUIDs need identity resolution; generic family records never override a hard chemical/form/route contradiction.Supplier/native originals and compatibility measurements
dq_completeall inventory rowsRetain all three physical gates, whole preparations, raw/WIP/FG and separate loop/charge stocks with every inherited exchange vector; include all failed/idle/rework events, actual species and package directions.Full stock and operating-period reconciliation
dq_basisall inventory rowsUse unnormalized raw numerator records and only report_once for the matching actual Q; original old-cohort denominators persist. No fabricated weight, density, threshold, emission factor, ratio, life or activity range.Calibrations original units formulas and cohort history
dq_scopeall processesPrimary manufacturer capabilities and supplier guide are independent technical synthesis, not same-SKU factory evidence. No source marketing rates or grade-chart values become cap defaults; qualify actual site/period and uncertainty.wacker-silicone-processing; jerry-swim-cap-production; ukong-swim-cap-supply
dq_missingall processesA real missing terminal, route or basis prevents an authored method claim; a critical missing measurement/species/history makes the concrete dataset incomplete. Ordinary auxiliary UUID/provider/future factory-data requirements alone do not imply an invented numeric result or universal scientific approval.Explicit missing-data and uncertainty register

9. Validation Rules

rule_idApplies toRulesource_ids
validate_referencereleased_capRequire the actual complete unprinted nonprotective LSR cap and every qualifier; 1 kg net new first-release basis must select this sole linked reference row in both languages. Do not infer per-cap weight or let generic native headgear identity replace route evidence.jerry-swim-cap-production; ukong-swim-cap-supply; un-cpc3-2025
validate_measurementall inventory rowsVerify raw units/rates and measured state, unique Q, whole formulation count, complete stock vectors and original cohort denominators; report_once executes once only. Q=0, unsupported conversion or missing critical relationships cannot yield a passing concrete dataset.
validate_physicalall processesIndependently reconcile manufacturing, FG and combined physical mass/elements, actual species/phase data, separate water/equipment charges and every package article/direction; cancel only internal transfers. Do not solve two unknowns from one residual or erase gross dispatch through reuse/allocation.
validate_nativeall inventory rowsAdopted Product/Waste/resource/emission type, CAS, material state, particle structure, supply geography/voltage and actual compartment must agree with original native restrictions. Distinguish ordinary air from long-term/indoor/water outlets; a family name or taxonomic correction is not compatibility proof.
validate_allocationall inventory rowsDemonstrate exclusive/virtual subdivision and per-exchange determining physical cause before any genuine residual common-gate market-value allocation. Preserve exact full-period failures, zero-output and historical stock burdens; missing evidence stays explicit.jrc-ilcd-2010
validate_qualityreleased_capRequire actual geometry/visual/fit/cure and declared strength acceptance, A/B storage compatibility and real finishing/postcure evidence. No performance, certification or lifetime can be inferred from a manufacturer page or a supplier example chart.wacker-silicone-processing; jerry-swim-cap-production; ukong-swim-cap-supply
validate_asset_manufacture_conservationexisting capital/reusable manufacture attributionFor every included capital/reusable manufacture attribution verify same-asset continuity, whole installed service in matched units, all historical/current beneficiaries, prior assigned manufacture shares and cumulative share <= 1. Reject a reset by period, cohort, provider, owner or repair. Check distinct real replacement and incremental repair/treatment vectors separately and preserve gross physical mass. A missing denominator, unexplained previous allocation or incomplete beneficiary ledger requires explicit review and an unavailable final attributed amount; structural inspection cannot claim empirical completeness.

10. Published Dataset Profile

FieldValue
dataset_rolesecondary_dataset; background_dataset
downstream_useActual compatible cap supply in a larger LCA with declared geography/period and lot basis
allowed_useQualified complete unprinted LSR cap production; include only observed attributed FG services and disclose remaining service scope
excluded_useWhole leaf coverage; safety helmets; textile/latex/HCR routes; printed/laminated caps; protective claims; unmeasured product footprints
required_metadataEvery reference qualifier; original lot denominators; full unit/source/provider/stock/physical gate history
required_quality_disclosureActual measured scope uncertainty missing auxiliary identities future services and pending scientific/translation review
update_triggerChanged A/B formulation geometry cure method electricity boundary supplier site period acceptance or evidence

11. Data Sources

Source idTypeReferenceUsed for
un-cpc3-2025official_guidancehttps://unstats.un.org/unsd/classifications/Econ/Download/In%20Text/CPC_Ver_3.0_Structure_30Jun2025.csvUN CPC3 structure of30June2025; classification boundary context only
wacker-silicone-processinghandbookhttps://www.wacker.com/h/medias/6709-EN.pdfSolid and Liquid Silicone Rubber — Material and Processing Guidelines; complete pp10/12/13/36/37/48-59/66-68; whole preparations and addition-cure/LSR injection/finishing context with peroxide/HCR/2K counterexamples; no numerical cap defaults or LCA allocation
jerry-swim-cap-productionliteraturehttps://jerrygoggles.com/swim-caps/Independent primary swim-cap manufacturing capability from material/mixing/vulcanization through moulding finishing/QC and packaging; alternative textile/latex/printing claims excluded; no audited quantities or certification adoption
ukong-swim-cap-supplyliteraturehttps://www.ukongtech.com/product-detail/customswimcaps/Independent primary plain/blank silicone swim-cap supply endpoint and general moulding capability; printing/marketing/use-care instructions not production defaults
jrc-ilcd-2010official_guidancehttps://eplca.jrc.ec.europa.eu/uploads/ILCD-Handbook-General-guide-for-LCA-DETAILED-GUIDANCE-12March2010-ISBN-fin-v1.0-EN.pdfFirst edition March2010, complete §§7.9.2-7.9.3 pp255-272/PDF275-292 including situation/attributional/recycling limitations; exclusive/virtual subdivision then determining physical causality then genuine residual common-gate actual-state market value, no fixed factors

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page