1. Scope and Applicability

This bounded method manufactures complete unprinted single-layer solid LSR silicone swimming caps by metering two purchased compatible whole A/B preparations, mixing, injection into an electrically heated mould, platinum-catalyzed addition cure, demoulding, actual trimming/conditioning and inspection to unique first quality release. Retain actual optional electric postcure and all real storage, packaging, handling and dispatch services. The selected electricity identity is limited to actual compatible Chinese less-than1kV user-side grid supply. [wacker-silicone-processing; jerry-swim-cap-production; ukong-swim-cap-supply]

WACKER supplies the complete material/processing context, Jerry independently describes silicone swim-cap mixing/vulcanization, compression/injection, finishing/QC and packaging, and UKONG independently offers plain/blank moulded silicone caps. This is an explicit technical synthesis, not proof of one common SKU, factory, current order or WACKER grade at either cap producer. Capability/marketing figures, numerical mould settings, A/B ratios, material properties, certification, chlorine/tear performance, cap weight, yield, emissions and lifetime are not adopted as defaults. [wacker-silicone-processing; jerry-swim-cap-production; ukong-swim-cap-supply]

Exclude safety helmets, textile/lycra caps, latex-dipped caps, HCR compression/extrusion, peroxide/condensation cure, foam, bonded inserts/multicomponent construction, printing/coating and purchased-finished-cap repacking. The reviewed platinum-cured VMQ tube-coil method ends at extruded HCR tubing and cannot replace the cap-specific LSR metering/cold-runner/hot-mould/geometry/release method. Shared curing principles alone do not make these product/route boundaries identical. Any actual changed operation requires complete atomic inventory and renewed applicability review. [wacker-silicone-processing; jerry-swim-cap-production; ukong-swim-cap-supply]

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.other-transportable-goods-except-metal-products-machinery-and-equipment.rubber-and-plastics-products.other-headgear-of-rubber-or-plastics
classification_refsCPC3.0 36972; narrower proposed context only
covered_productsComplete unprinted single-layer platinum-addition-cured LSR swim caps
excluded_productsAll exclusions in section1; a cap is neither protective helmet nor tube coil
representative_productOne actual declared cap geometry and compatible A/B formulation pair
production_routePurchased whole A/B; metering/mixing; injection/electric hot mould cure; demould/trim/actual conditioning; tests/first release
market_stateNewly first-released complete net cap; all removable packaging excluded; actual FG services separate

The retained UN structure lists other rubber/plastic headgear beside safety headgear and insulating fittings. It defines scope context, not a silicone recipe or accepted PCR mapping. [un-cpc3-2025]

3. Reference Flow

FieldValue
WhatProvide the declared complete flexible swimming cap
How much1 kg reference flow
How wellActual dimensional/fit/visual/cure and specified stretch/tear acceptance; no universal performance or safety claim
How long or cycleOne unique new first-quality-release event; actual use life is not inferred
reference_flow_linkreleased_cap
FieldValue
Reference amount1
Reference product flowOther headgear of rubber or plastics 242b7130-c930-4bbc-b859-0790c44ef2cd
Reference flow propertyMass 93a60a56-a3c8-11da-a746-0800200b9a66
Reference unit groupUnits of mass 93a60a57-a4c8-11da-a746-0800200c9a66
Reference unitkg
Required qualifierswhole A/B grade and supplier composition; compatible batch pairing and storage/pot-life history; actual polymer filler catalyst and residual assays; cap shape thickness size and layer configuration; unprinted nonprotective product function; real cure and optional postcure recipe; geometry-specific first-release test methods and limits; conditioning and net cap mass excluding tare; electricity voltage geography and provider boundary; raw WIP water-loop and equipment stock locations; every inherited exchange vector by stock lot; unique first-release lot IDs and Q; FG gross dispatch return and original denominator history; each packaging article complete custody and tare; actual gas species media and measurement conditions; full period failed idle cleanup and rework loads; supplier upstream links uncertainty and missing scope

Declare all qualifiers in the concrete data package. Native Product flow is finished manufactured rubber/plastic headgear at plant with Mass reference factor1. It supplies no CAS, polymer grade, particular cap geometry, technology, lifetime, certification or supply geography; there are no synonyms or other properties. The Chinese general comment loosely says head protection whereas the English identity and leaf distinguish other headgear from safety headgear: this record establishes no protective function. Use only the independently qualified complete unprinted single-layer platinum-addition-cured LSR swim cap specified here, excluding safety helmets and textile caps. Actual formulation, geometry, cure, fit and first-release tests remain required.

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
reference_massreference productMass 93a60a56-a3c8-11da-a746-0800200b9a66kgUse actual accepted complete net cap mass at first release after conditioning. Count and dimensional data never imply a fixed kg per cap; any optional count-to-mass conversion needs paired calibrated net weighing by the same grade/geometry/configuration lot and separate measured counts.
whole_preparationlsr_a; lsr_b; release_agentMasskgEach complete purchased preparation counts once. Actual polymer/filler/catalyst/carrier assays are child balances; onsite formulation beyond compatible A/B dosing requires separate actual purchased ingredients and actual mixing energy/loss with route review.
raw_conversionall inventory rowsActual numerator propertyoriginal unitConvert raw units before allocation: actual kWh times3.6 gives MJ; integrate actual rates over measured intervals, but never multiply an already integrated gas/liquid volume by time again. Convert volume to mass only with independent density/composition of that actual material at measured state; no water density for oil and no secondary property coefficient treated as density.
raw_not_unit_resultall inventory rowsActual numerator propertyoriginal unitCollect undivided raw numerators. Unit conversion, exclusive attribution and inherited-stock-vector reconciliation precede the sole report_once calculation. Cards and collection aggregation point to that same calculation and never divide a unit result again.

5. System Boundary

Boundary Abstraction

FieldValue
declared_starting_conditionPurchased whole uncured compatible LSR A/B and actual auxiliaries; real lot/site/stock supply states
starting_condition_roleforeground_gate_to_gate
product_classification_scopeNarrow non-textile nonprotective silicone swim-cap subset
recursive_input_ruleAlready finished caps are not raw LSR. Returned released caps retain original lot histories; internal material transfers are neither purchases nor fresh production.
upstream_dataset_requirementLink actual whole A/B formulations and each actual utility/auxiliary/packaging supply and waste treatment once; retain supplier manufacture upstream
disclosureSeparate manufacturing first release, FG service and combined physical gates; disclose missing conditions and incomplete future services
rule_idApplies toRulesource_ids
boundary_routeall processesInclude receipt/storage, paired dosing/mixing, real cold-runner and hot-mould injection/cure, demould, actual flash/sprue trim, cleaning, conditioning/testing and unique first release. Include actual optional electric postcure, cooling, air, vacuum, maintenance, storage/packing/dispatch services and failure/idle loads. No boiler, external steam, fuel firing or peroxide reaction is presumed; changed actual operations require full single-material/species inventory and applicability review.wacker-silicone-processing; jerry-swim-cap-production
boundary_qreleased_capQ is the sum of uniquely identified NEW first-accepted complete net cap kg. Reinspection, delivery, returns, reopening or redelivery creates no new Q. Closing released FG already belongs to Q once; do not add it as an extra manufacturing output. Q=0 retains all actual loads and yields no unit result.jerry-swim-cap-production
boundary_stockall inventory rowsKeep separate raw A, raw B, mixed material in feed/mixer/runner, uncured/cured unaccepted WIP and retained tests by actual location/lot/state. Opening stock plus actual receipts/transfers equals closing stock plus actual consumption/exports/losses. For EVERY exchange carry opening inherited burden vector, add real current increments, transfer internal vectors once, retain closing vector and original denominator/history. Preserve all failed/zero-output/start-stop/idle/cleanup/rework burdens. Keep cooling-loop water, hydraulic charge, refrigerant charge and other equipment stocks with their own physical quantity AND inherited exchange vectors wherever outside raw/WIP; name locations and eliminate overlap.
boundary_fgfg_in; fg_return; fg_out; fg_power; waste_fgFG gate: openingFG + newFirstReleaseQ + externalReturnedCaps = closingFG + grossOutwardCapsG + actualFGWaste. Preserve each old FG/return cohort original production numerator, original Q and delivery reversal history. Attribute actual storage/packing/handling/dispatch and incremental rework services to that lot with its own historical denominator, never unrelated current Q. Manufacturing and FG combined gates cancel internal Q transfers; they do not add first release and closing FG twice. Future services not yet observed stay disclosed incomplete.
boundary_packall packaging rowsFor EACH separate article: opening empty + opening attachedWIP + opening attachedFG + opening reusable + new external purchase/receipt + externalReturnReceived = closing empty + closing attachedWIP + closing attachedFG + closing reusable + article accompanying gross physical dispatch + externalReturnSent + waste. Distinguish purchase from attached supplier receipts to prevent duplicate entries; track residual contents independently. All five external directions have separate cards. Internal reuse cancels and never reduces gross outward mass, raises net product Q, creates new purchase or earns automatic coproduct/avoided-burden credit. Add each genuinely used different article/material before modelling.
boundary_waterwater_makeup; wash_water; external_cooling_in; external_cooling_out; water_vapourClose physical total mass and relevant Si/C/H/O balances independently from analytical species/phase evidence at manufacturing, FG and combined gates. Separate free moisture, emulsion carrier, ambient moisture, retained water, actual evaporation/condensate/effluent and independently evidenced reaction/structural water. Addition hydrosilylation does not justify inventing water byproduct; no two unknown masses from one residual, and no species mass from COD/TVOC. External water returns remain real Product outputs with measured state/enthalpy and supplier energy/water convention; internal cooling recirculation is not purchase.wacker-silicone-processing
boundary_speciesall elementary rowsActual ventilation/pneumatic gas carries individually measured nitrogen, oxygen, argon, atmospheric-origin CO2 and water plus each genuine process species. Purchased compressed-air species are child carrier accounts, not duplicate resource intake. Quantify actual D4/D5/D6 and other siloxanes separately only if detected/otherwise evidenced; addition cure is not proof of zero volatile release. Species leaving with wastewater or waste remains in that outlet, not also emitted to air. Add each actual new species/size fraction/compartment and capture-residue destination; no unspecified VOC/PM surrogate mass.wacker-silicone-processing
boundary_qualitylsr_a; lsr_b; released_capIndependently verify matching A/B formulation, storage/pot life and inhibitor/cross-contamination controls; actual acceptance covers complete cap geometry, surface, cure and declared service tests. Compression/HCR, peroxide, textile or printed cap evidence is not an LSR production recipe. Postcure depends on actual supplier/product qualification; retain genuine postcure electricity, ventilated species and failures, never enforce a universal temperature/time from a thick-sheet chart.wacker-silicone-processing; jerry-swim-cap-production; ukong-swim-cap-supply

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
cap_productionComplete cap manufacture and separately accounted actual FG servicesrequireddeclared LSR routeforeground1 kg net new first-release cap; lot-specific FG services separately retained

The integrated process contains manufacturing and FG custody/service subledgers with separate physical gates. Q is an internal first-release reference; all real outside movements remain visible. Conditional cards do not establish presence/absence: verify applicability and add every actual unlisted single input, waste and species before dataset use.

Process: Complete LSR swimming-cap production (cap_production)

Inputs

Product flows
Whole LSR component A preparation (lsr_a)

Purchase the complete qualified filled LSR A component in its real supplied state. Catalyst, polymer, silica, inhibitor and residuals already inside that preparation remain child composition accounts. Pair the actual compatible A/B grade and lot; no pure silicone, organic-silicone family or latex UUID is interchangeable.

  • Selected flow: Whole LSR component A preparation
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_material
  • Sources: wacker-silicone-processing
Whole LSR component B preparation (lsr_b)

Purchase the complete matching B preparation with its actual crosslinker/polymer/filler content. Meter raw A and B separately, retain mixing loss and pot-life failures; take the approved supplier ratio from the real grade, not a universal prescribed fraction.

  • Selected flow: Whole LSR component B preparation
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_material
  • Sources: wacker-silicone-processing
Manufacturing electricity (power_mfg)

Meter receiving, dosing, mixer, injection drive, electric mould heating, cooling pumps/chiller, compressor, vacuum, ventilation, optional actual electric postcure, trimming, quality tests, all failed starts/idle/cleanup/rework. Separate FG services and shared meters before attribution. Native Product flow is alternating current with fixed CN supply geography, less-than1kV consumption mix delivered to user and grid-average supply. Its only reference property is Net calorific value with factor1 on MJ basis; this is the platform energy convention, not combustion of electricity. AC is the synonym; its comment describes mixed fossil/nuclear/renewable generation and production/transmission to consumer, not a dedicated renewable source or a supplier emission factor. Use this UUID only when actual Chinese low-voltage grid supply, delivery boundary and provider are compatible; other voltage/geography/onsite generation needs a separate verified flow. Avoid double counting grid losses or compressor/chiller electricity.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_energy
  • Sources: wacker-silicone-processing
Cooling-loop makeup water (water_makeup)

Only actual external makeup enters the inventory; pump circulation is internal. Record independent loop opening/closing charge and inherited burden, blowdown, evaporation and leaks without overlap with raw/WIP water. Native Process water is Product/Mass with reference factor1 and no CAS, synonyms, composition, purification route, supply geography or other properties. The retained older source classification says other goods; the current water classification does not establish treatment or provider quality. Qualify actual purchased industrial water and its upstream supply. Do not use it for raw environmental abstraction, return heat-transfer water, steam, wastewater or another whole chemical preparation. Volume-to-mass needs this water actual measured state/density, never an assumed secondary property.

  • Selected flow: Process water bedc466a-fd2e-4a6d-9f93-f334f0cd552c
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_water
  • Sources: wacker-silicone-processing
Cleaning water (wash_water)

Measure actual external cleaning/rinse water separately from cooling makeup and water already contained in any preparation. Actual cleaning effluent and phase loss are separately measured. Native Process water is Product/Mass with reference factor1 and no CAS, synonyms, composition, purification route, supply geography or other properties. The retained older source classification says other goods; the current water classification does not establish treatment or provider quality. Qualify actual purchased industrial water and its upstream supply. Do not use it for raw environmental abstraction, return heat-transfer water, steam, wastewater or another whole chemical preparation. Volume-to-mass needs this water actual measured state/density, never an assumed secondary property.

  • Selected flow: Process water bedc466a-fd2e-4a6d-9f93-f334f0cd552c
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_water
  • Sources: wacker-silicone-processing
External heat-transfer cooling water supply (external_cooling_in)

Conditional on a real external water loop; preserve supplied liquid mass, temperature, pressure and enthalpy with the actual supplier water/energy accounting agreement. It is not fresh makeup nor a presumed steam supply.

  • Selected flow: External heat-transfer cooling water supply
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_water
  • Sources: wacker-silicone-processing
Whole emulsified mould-release preparation (release_agent)

Conditional actual startup/demould use; record compatibility, application and loss. No automatic routine dose is imposed. Native Release agent is one Product/Mass preparation with factor1, at-plant production mix and the explicit emulsified surface-active-agent-modification route. Synonyms describe mould separation/release coating; the general comment is a descriptive template and supplies no formulation, CAS, active fraction, supplier or fixed geography. Use only one actual compatible emulsified mould-release preparation for this silicone route, confirmed by complete supplier SDS/composition and inhibition tests. Whole emulsion is purchased once; carrier water and active silicone are child assays. Non-emulsified solvent/other chemistry needs another flow and route review.

  • Selected flow: Release agent 5fcf34f0-05a0-4892-84cd-be4173fffa48
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_material
  • Sources: wacker-silicone-processing
Hydraulic oil makeup (hydraulic_oil)

Conditional on actual hydraulic equipment; meter charge/makeup and drained oil separately. Electric drives do not justify an invented oil consumption. Native Hydraulic Fluid is Product with Volume as its sole reference property and factor1. Hydraulic oil synonyms and comment describe a formulated mineral-or-synthetic base oil with additives for hydraulic power transfer, lubrication and heat transfer. No CAS, grade, supply geography or mass property is declared; lubricant classification alone does not identify the base oil. Use only actual compatible hydraulic oil as one whole preparation, in measured m3 at declared temperature; independently measure that oil density for the physical mass ledger. Charge opening/closing and inherited burdens persist; no assumed kg per litre.

  • Selected flow: Hydraulic Fluid 30691a38-a947-4b41-991e-194f6c9aa88f
  • Flow property / unit: Volume / m3
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_charge
  • Sources: wacker-silicone-processing
Purchased compressed air (air_service)

Conditional purchased pneumatic supply; preserve measured gross carrier-gas mass in species subaccounts and actual liquid/oil carryover. Native Compressed air is Product/Volume with reference factor1; synonyms and comment identify above-atmospheric-pressure air for pneumatic power or atomization, with no CAS, supply geography, purity, drying class, pressure/temperature basis or mass property. Use only externally supplied compatible compressed air and declared meter reference conditions. Onsite compression uses actual electricity and atmospheric intake instead; never purchase the same air twice. Derive species mass only from independently measured composition and state; its supply already includes carrier mass, not a second atmospheric-resource input.

  • Selected flow: Compressed air 46e2b1e4-5a4e-4579-b6a2-65b03f9ce825
  • Flow property / unit: Volume / m3
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_air
  • Sources: wacker-silicone-processing
Isopropanol cleaning liquid (ipa)

Conditional actual IPA cleaning; record whole supplied purity/water and contamination state. Other cleaning formulations require their own complete single-material cards.

  • Selected flow: Isopropanol cleaning liquid
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_material
  • Sources: wacker-silicone-processing
R134a refrigerant charge (r134a_in)

Only for an actual R134a cooling circuit, with identified charge, recovered stock, leak and service records. Another refrigerant is a distinct exchange, not an R134a default.

  • Selected flow: R134a refrigerant charge
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_charge
  • Sources: wacker-silicone-processing
Polypropylene filter cartridge (filter_in)

Conditional actual water-treatment filter; identify the complete supplied cartridge and replace polymer/structure if the real cartridge differs. Track retained water/solids separately from dry cartridge.

  • Selected flow: Polypropylene filter cartridge
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_material
  • Sources: wacker-silicone-processing
Road freight transport service (freight)

Actual inbound and foreground intersite/return carriage by identified trip and article, including real packaging mass; measure loaded mass and distance. No assumed truck capacity, distance, backhaul or factor. Avoid repeating transport already included by a supply provider.

  • Selected flow: Road freight transport service
  • Flow property / unit: Transport service / t.km
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_transport
  • Sources: wacker-silicone-processing
Newly released cap internal receipt (fg_in)

Internal transfer from released_cap into the FG service ledger; cancel this transfer when combining gates. It is neither bought cap nor an additional production burden. Native Product flow is finished manufactured rubber/plastic headgear at plant with Mass reference factor1. It supplies no CAS, polymer grade, particular cap geometry, technology, lifetime, certification or supply geography; there are no synonyms or other properties. The Chinese general comment loosely says head protection whereas the English identity and leaf distinguish other headgear from safety headgear: this record establishes no protective function. Use only the independently qualified complete unprinted single-layer platinum-addition-cured LSR swim cap specified here, excluding safety helmets and textile caps. Actual formulation, geometry, cure, fit and first-release tests remain required.

  • Selected flow: Other headgear of rubber or plastics 242b7130-c930-4bbc-b859-0790c44ef2cd
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_fg
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
Externally returned released cap (fg_return)

Actual external return by original lot, original first-release denominator/history and physical condition. Retest or redelivery adds no production Q; record real extra work in its old cohort service account. Native Product flow is finished manufactured rubber/plastic headgear at plant with Mass reference factor1. It supplies no CAS, polymer grade, particular cap geometry, technology, lifetime, certification or supply geography; there are no synonyms or other properties. The Chinese general comment loosely says head protection whereas the English identity and leaf distinguish other headgear from safety headgear: this record establishes no protective function. Use only the independently qualified complete unprinted single-layer platinum-addition-cured LSR swim cap specified here, excluding safety helmets and textile caps. Actual formulation, geometry, cure, fit and first-release tests remain required.

  • Selected flow: Other headgear of rubber or plastics 242b7130-c930-4bbc-b859-0790c44ef2cd
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_fg
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
Post-release service electricity (fg_power)

Retain real FG warehouse, packing, handling and dispatch electricity and incremental return work by lot and service period. Services of old FG and returned lots retain their own original denominator; do not transfer their burdens to unrelated current Q. Native Product flow is alternating current with fixed CN supply geography, less-than1kV consumption mix delivered to user and grid-average supply. Its only reference property is Net calorific value with factor1 on MJ basis; this is the platform energy convention, not combustion of electricity. AC is the synonym; its comment describes mixed fossil/nuclear/renewable generation and production/transmission to consumer, not a dedicated renewable source or a supplier emission factor. Use this UUID only when actual Chinese low-voltage grid supply, delivery boundary and provider are compatible; other voltage/geography/onsite generation needs a separate verified flow. Avoid double counting grid losses or compressor/chiller electricity.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_fg_energy
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
External receipt of Whole steel supply drum (drum_in)

One actual whole whole steel supply drum. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record actual new external purchase or supplier-attached article receipt once; no repeated purchase for internal reuse. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: External receipt of Whole steel supply drum
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
External return received of Whole steel supply drum (drum_return_received)

One actual whole whole steel supply drum. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record actual external returned article by original custody lot; not a new purchase. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: External return received of Whole steel supply drum
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
External receipt of LDPE cap bag (pe_bag_in)

One actual whole ldpe cap bag. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record actual new external purchase or supplier-attached article receipt once; no repeated purchase for internal reuse. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: External receipt of LDPE cap bag
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
External return received of LDPE cap bag (pe_bag_return_received)

One actual whole ldpe cap bag. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record actual external returned article by original custody lot; not a new purchase. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: External return received of LDPE cap bag
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
External receipt of Corrugated shipping carton (carton_in)

One actual whole corrugated shipping carton. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record actual new external purchase or supplier-attached article receipt once; no repeated purchase for internal reuse. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: External receipt of Corrugated shipping carton
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
External return received of Corrugated shipping carton (carton_return_received)

One actual whole corrugated shipping carton. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record actual external returned article by original custody lot; not a new purchase. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: External return received of Corrugated shipping carton
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
External receipt of Whole polypropylene pressure-sensitive sealing tape (tape_in)

One actual whole whole polypropylene pressure-sensitive sealing tape. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record actual new external purchase or supplier-attached article receipt once; no repeated purchase for internal reuse. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: External receipt of Whole polypropylene pressure-sensitive sealing tape
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
External return received of Whole polypropylene pressure-sensitive sealing tape (tape_return_received)

One actual whole whole polypropylene pressure-sensitive sealing tape. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record actual external returned article by original custody lot; not a new purchase. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: External return received of Whole polypropylene pressure-sensitive sealing tape
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
External receipt of Softwood shipping pallet (pallet_in)

One actual whole softwood shipping pallet. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record actual new external purchase or supplier-attached article receipt once; no repeated purchase for internal reuse. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: External receipt of Softwood shipping pallet
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
External return received of Softwood shipping pallet (pallet_return_received)

One actual whole softwood shipping pallet. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record actual external returned article by original custody lot; not a new purchase. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: External return received of Softwood shipping pallet
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
External receipt of LLDPE pallet stretch film (wrap_in)

One actual whole lldpe pallet stretch film. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record actual new external purchase or supplier-attached article receipt once; no repeated purchase for internal reuse. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: External receipt of LLDPE pallet stretch film
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
External return received of LLDPE pallet stretch film (wrap_return_received)

One actual whole lldpe pallet stretch film. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record actual external returned article by original custody lot; not a new purchase. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: External return received of LLDPE pallet stretch film
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
Waste flows
Elementary flows
Nitrogen from ambient air (nitrogen_in)

Only actual onsite compressor/ventilation intake. This species is determined independently from measured gas composition and integrated intake/state. Purchased compressed-air carrier belongs to that product subaccount instead; do not count the same intake twice.

  • Selected flow: Nitrogen from ambient air
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_air
  • Sources: wacker-silicone-processing
Oxygen from ambient air (oxygen_in)

Only actual onsite compressor/ventilation intake. This species is determined independently from measured gas composition and integrated intake/state. Purchased compressed-air carrier belongs to that product subaccount instead; do not count the same intake twice.

  • Selected flow: Oxygen from ambient air
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_air
  • Sources: wacker-silicone-processing
Argon from ambient air (argon_in)

Only actual onsite compressor/ventilation intake. This species is determined independently from measured gas composition and integrated intake/state. Purchased compressed-air carrier belongs to that product subaccount instead; do not count the same intake twice.

  • Selected flow: Argon from ambient air
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_air
  • Sources: wacker-silicone-processing
Atmospheric-origin carbon dioxide from ambient air (co2_in)

Only actual onsite compressor/ventilation intake. This species is determined independently from measured gas composition and integrated intake/state. Purchased compressed-air carrier belongs to that product subaccount instead; do not count the same intake twice.

  • Selected flow: Atmospheric-origin carbon dioxide from ambient air
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_air
  • Sources: wacker-silicone-processing
Atmospheric water vapour intake (air_moisture_in)

Measure humidity and actual ambient-air intake to account for carrier moisture; it is not new process water nor evidence of reaction water.

  • Selected flow: Atmospheric water vapour intake
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_air
  • Sources: wacker-silicone-processing

Outputs

Product flows
New first-quality-released cap (released_cap)

Q is unique newly accepted complete net cap kg after real finishing/conditioning/inspection, before FG services. Rejects, destructive tests and unaccepted WIP are outside Q. Already released closing FG is included in Q once and is not a second output. Native Product flow is finished manufactured rubber/plastic headgear at plant with Mass reference factor1. It supplies no CAS, polymer grade, particular cap geometry, technology, lifetime, certification or supply geography; there are no synonyms or other properties. The Chinese general comment loosely says head protection whereas the English identity and leaf distinguish other headgear from safety headgear: this record establishes no protective function. Use only the independently qualified complete unprinted single-layer platinum-addition-cured LSR swim cap specified here, excluding safety helmets and textile caps. Actual formulation, geometry, cure, fit and first-release tests remain required.

  • Selected flow: Other headgear of rubber or plastics 242b7130-c930-4bbc-b859-0790c44ef2cd
  • Flow property / unit: Mass / kg
  • Amount rule: 1 kg
  • Value mode: fixed_value
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: source_rule
  • Collection protocol: cp_quality
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
Gross outward released-cap carriage (fg_out)

Gross physical shipment by actual lot includes old FG and redelivery, separate from new production Q. Maintain return/reversal history and actual packaging separately. Combining the gates cancels internal released_cap/fg_in, not gross outward physical mass. Native Product flow is finished manufactured rubber/plastic headgear at plant with Mass reference factor1. It supplies no CAS, polymer grade, particular cap geometry, technology, lifetime, certification or supply geography; there are no synonyms or other properties. The Chinese general comment loosely says head protection whereas the English identity and leaf distinguish other headgear from safety headgear: this record establishes no protective function. Use only the independently qualified complete unprinted single-layer platinum-addition-cured LSR swim cap specified here, excluding safety helmets and textile caps. Actual formulation, geometry, cure, fit and first-release tests remain required.

  • Selected flow: Other headgear of rubber or plastics 242b7130-c930-4bbc-b859-0790c44ef2cd
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_fg
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
External heat-transfer water return (external_cooling_out)

Actual return to the external supplier remains a Product physical output with measured mass/state/enthalpy and agreed energy-water boundary. It is not a waste effluent or a credit; close supply plus opening loop charge against return, other actual losses and closing charge.

  • Selected flow: External heat-transfer water return
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_water
  • Sources: wacker-silicone-processing
Recovered R134a for external return (r134a_recovered)

Actual separately recovered refrigerant physically sent to a supplier/reclaimer; identify purity, destination and ownership. Storage remains charge stock, waste disposition uses a separate waste card, and no virgin substitution credit is automatic.

  • Selected flow: Recovered R134a for external return
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_charge
  • Sources: wacker-silicone-processing
Gross outward carriage of Whole steel supply drum (drum_out)

One actual whole whole steel supply drum. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record article mass accompanying every gross outward physical cap shipment, including old FG and redelivery; allocation or reuse never reduces this real outward mass. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: Gross outward carriage of Whole steel supply drum
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
External return sent of Whole steel supply drum (drum_return)

One actual whole whole steel supply drum. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record actual separate return to supplier/pool/customer with destination; do not combine with dispatch or received returns. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: External return sent of Whole steel supply drum
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
Gross outward carriage of LDPE cap bag (pe_bag_out)

One actual whole ldpe cap bag. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record article mass accompanying every gross outward physical cap shipment, including old FG and redelivery; allocation or reuse never reduces this real outward mass. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: Gross outward carriage of LDPE cap bag
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
External return sent of LDPE cap bag (pe_bag_return)

One actual whole ldpe cap bag. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record actual separate return to supplier/pool/customer with destination; do not combine with dispatch or received returns. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: External return sent of LDPE cap bag
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
Gross outward carriage of Corrugated shipping carton (carton_out)

One actual whole corrugated shipping carton. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record article mass accompanying every gross outward physical cap shipment, including old FG and redelivery; allocation or reuse never reduces this real outward mass. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: Gross outward carriage of Corrugated shipping carton
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
External return sent of Corrugated shipping carton (carton_return)

One actual whole corrugated shipping carton. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record actual separate return to supplier/pool/customer with destination; do not combine with dispatch or received returns. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: External return sent of Corrugated shipping carton
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
Gross outward carriage of Whole polypropylene pressure-sensitive sealing tape (tape_out)

One actual whole whole polypropylene pressure-sensitive sealing tape. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record article mass accompanying every gross outward physical cap shipment, including old FG and redelivery; allocation or reuse never reduces this real outward mass. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: Gross outward carriage of Whole polypropylene pressure-sensitive sealing tape
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
External return sent of Whole polypropylene pressure-sensitive sealing tape (tape_return)

One actual whole whole polypropylene pressure-sensitive sealing tape. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record actual separate return to supplier/pool/customer with destination; do not combine with dispatch or received returns. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: External return sent of Whole polypropylene pressure-sensitive sealing tape
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
Gross outward carriage of Softwood shipping pallet (pallet_out)

One actual whole softwood shipping pallet. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record article mass accompanying every gross outward physical cap shipment, including old FG and redelivery; allocation or reuse never reduces this real outward mass. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: Gross outward carriage of Softwood shipping pallet
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
External return sent of Softwood shipping pallet (pallet_return)

One actual whole softwood shipping pallet. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record actual separate return to supplier/pool/customer with destination; do not combine with dispatch or received returns. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: External return sent of Softwood shipping pallet
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
Gross outward carriage of LLDPE pallet stretch film (wrap_out)

One actual whole lldpe pallet stretch film. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record article mass accompanying every gross outward physical cap shipment, including old FG and redelivery; allocation or reuse never reduces this real outward mass. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: Gross outward carriage of LLDPE pallet stretch film
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
External return sent of LLDPE pallet stretch film (wrap_return)

One actual whole lldpe pallet stretch film. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record actual separate return to supplier/pool/customer with destination; do not combine with dispatch or received returns. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: External return sent of LLDPE pallet stretch film
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
Waste flows
Uncured mixed LSR purge waste (lsr_purge)

Actual A/B mixed expired/purged residue; retain whole preparation mass and composition, destination and original burden. It is not cured scrap and never automatically recyclable.

  • Selected flow: Uncured mixed LSR purge waste
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_waste
  • Sources: wacker-silicone-processing; jerry-swim-cap-production
Cured silicone cap trim and reject waste (cured_scrap)

Measure actual same-material cured sprues, flash, failed caps and destructive-test pieces at separate generation points; combine only verified identical material/destination without hiding other materials. No remelt regrind loop is presumed for crosslinked silicone.

  • Selected flow: Cured silicone cap trim and reject waste
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_waste
  • Sources: wacker-silicone-processing; jerry-swim-cap-production
Spent hydraulic oil (spent_oil)

Actual drained whole used oil, including assayed contamination; reconcile equipment charge and any true leakage separately.

  • Selected flow: Spent hydraulic oil
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_charge
  • Sources: wacker-silicone-processing; jerry-swim-cap-production
Spent isopropanol cleaning liquid (spent_ipa)

Measure actual whole collected IPA cleaning residue with water and contaminants; do not equate residue mass to pure emitted IPA.

  • Selected flow: Spent isopropanol cleaning liquid
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_waste
  • Sources: wacker-silicone-processing; jerry-swim-cap-production
Silicone-moulding cleaning wastewater (water_effluent)

Actual collected liquid wastewater to an identified external treatment system, with separately measured volume/mass and actual dissolved/suspended composition. COD/TVOC are indicators, not named chemical masses.

  • Selected flow: Silicone-moulding cleaning wastewater
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_water
  • Sources: wacker-silicone-processing; jerry-swim-cap-production
Cooling-loop blowdown wastewater (water_blowdown)

Actual separate external blowdown; not circulating flow or supplier return. Preserve dissolved treatment chemicals and independently evidenced contamination; add each real treatment purchase first.

  • Selected flow: Cooling-loop blowdown wastewater
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_water
  • Sources: wacker-silicone-processing; jerry-swim-cap-production
Spent polypropylene filter cartridge (waste_filter)

The actual complete spent cartridge, including separate measured retained water/residue subaccounts and destination; not generic mixed plastic waste or purchased new filter.

  • Selected flow: Spent polypropylene filter cartridge
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_waste
  • Sources: wacker-silicone-processing; jerry-swim-cap-production
Post-release discarded silicone cap (waste_fg)

Actual FG loss/returned cap disposal retains original cohort history; it does not erase the historical production event or become new Q.

  • Selected flow: Post-release discarded silicone cap
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_fg
  • Sources: wacker-silicone-processing; jerry-swim-cap-production
Waste Whole steel supply drum (drum_waste)

One actual whole whole steel supply drum. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record actual whole discarded article and destination, separate from product flow and contents; no automatic coproduct/virgin-material credit. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: Waste Whole steel supply drum
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
Waste LDPE cap bag (pe_bag_waste)

One actual whole ldpe cap bag. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record actual whole discarded article and destination, separate from product flow and contents; no automatic coproduct/virgin-material credit. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: Waste LDPE cap bag
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
Waste Corrugated shipping carton (carton_waste)

One actual whole corrugated shipping carton. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record actual whole discarded article and destination, separate from product flow and contents; no automatic coproduct/virgin-material credit. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: Waste Corrugated shipping carton
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
Waste Whole polypropylene pressure-sensitive sealing tape (tape_waste)

One actual whole whole polypropylene pressure-sensitive sealing tape. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record actual whole discarded article and destination, separate from product flow and contents; no automatic coproduct/virgin-material credit. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: Waste Whole polypropylene pressure-sensitive sealing tape
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
Waste Softwood shipping pallet (pallet_waste)

One actual whole softwood shipping pallet. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record actual whole discarded article and destination, separate from product flow and contents; no automatic coproduct/virgin-material credit. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: Waste Softwood shipping pallet
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
Waste LLDPE pallet stretch film (wrap_waste)

One actual whole lldpe pallet stretch film. Identify complete composition, dry tare, any retained contents and provider; this specific material is conditional, not proof that a manufacturer uses it. Record actual whole discarded article and destination, separate from product flow and contents; no automatic coproduct/virgin-material credit. Apply the independent per-article full stock equation in boundary_pack, including empty, attached WIP/FG and reusable stocks; never add packaging to net cap Q. If composition differs, add the actual single article instead.

  • Selected flow: Waste LLDPE pallet stretch film
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: jerry-swim-cap-production; ukong-swim-cap-supply
Elementary flows
Gross external water-vapour outlet (water_vapour)

Measure the actual gross gaseous ordinary-H2O outlet after controls, including the uncondensed water-vapour fraction of atmospheric or purchased-air carrier moisture and actual cooling/cleaning/emulsion-carrier evaporation. Keep independently measured origin subaccounts within this one outlet; do not report process evaporation again as a second output. Do not assume all intake moisture leaves as vapour: independently reconcile condensation, retained water and stock changes. Liquid droplets, condensate and aqueous aerosols are different physical phases and need their own actual atomic outlet identities and destinations; never include them under this vapour UUID or fit unknown phase masses from one residual. Native Elementary flow is ordinary water vapour CAS7732-18-5 emitted to air unspecified, Mass reference factor1 and no geographic/technology restriction or extra property. Its broad registry synonyms include ice, isotope and bound-water words; those strings do not authorize an isotope, liquid water, structural water or reaction-water substitution. Quantify actual ordinary H2O evaporation by measured phase/species evidence, excluding internally condensed/recycled water and independently separating atmospheric moisture intake from new process-water evaporation. Reclassify actual identified emission compartment when available.

  • Selected flow: water vapour fe0acd60-3ddc-11dd-ac04-0050c2490048
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_species
  • Sources: wacker-silicone-processing
D4 emission to air (d4_air)

Conditional only when this actual species/outlet is established by chemistry and measurement; preserve detection limits and real control destination. Never infer its mass from total VOC, cap weight loss or total particulate. Missing critical speciation makes the concrete dataset incomplete; not a declared zero. Native Elementary flow identifies D4 CAS556-67-2 and EC209-136-7 with cyclic dimethylsiloxane-tetramer/OMCTS and supplier-name synonyms, ordinary emissions to air unspecified and sole Mass reference factor1. No geography, technology or grade is fixed. Supplier trade aliases do not make a whole silicone formulation equivalent to pure D4. Use only measured D4 species reaching the external atmosphere after real capture; no long-term, indoor, water, total-VOC or aggregate-siloxane substitution, and no default presence or amount.

  • Selected flow: octamethylcyclotetrasiloxane 06e8ead2-e79f-4c88-88f4-f6dddf8b6fc8
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_species
  • Sources: wacker-silicone-processing
Decamethylcyclopentasiloxane emission to air (d5_air)

Conditional only when this actual species/outlet is established by chemistry and measurement; preserve detection limits and real control destination. Never infer its mass from total VOC, cap weight loss or total particulate. Missing critical speciation makes the concrete dataset incomplete; not a declared zero.

  • Selected flow: Decamethylcyclopentasiloxane emission to air
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_species
  • Sources: wacker-silicone-processing
D6 emission to air (d6_air)

Conditional only when this actual species/outlet is established by chemistry and measurement; preserve detection limits and real control destination. Never infer its mass from total VOC, cap weight loss or total particulate. Missing critical speciation makes the concrete dataset incomplete; not a declared zero. Native Elementary flow identifies D6 CAS540-97-6 and EC208-762-8, ordinary emissions to air unspecified and sole Mass reference factor1; no geography or technology is fixed. Registry organometallic wording and named commercial-fluid synonyms are broad aliases, not metal content, a different particle structure or whole-mixture permission. Use only analytically identified D6 reaching external air after actual controls, not other cyclic siloxanes, total VOC, long-term/indoor/water emissions. Its identity provides no emission rate or recipe fraction.

  • Selected flow: dodecamethylcyclohexasiloxane 8d7827eb-ee42-48da-85af-8f22a2b291a8
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_species
  • Sources: wacker-silicone-processing
Isopropanol emission to air (ipa_air)

Conditional only when this actual species/outlet is established by chemistry and measurement; preserve detection limits and real control destination. Never infer its mass from total VOC, cap weight loss or total particulate. Missing critical speciation makes the concrete dataset incomplete; not a declared zero. Native Elementary flow is isopropanol CAS67-63-0 and EC200-661-7 to air unspecified with only Mass reference factor1, no geography/technology restriction. Its large synonym registry contains commercial rubbing-alcohol names, strong-acid-manufacturing labels and ambiguous isopropenol wording; these do not supersede the CAS-bound propan-2-ol molecule. Use only independently identified IPA emitted after real cleaning/capture, not purchased whole cleaner, n-propanol, isopropenol, total VOC or an assumed evaporated fraction. Other known compartments require another identity.

  • Selected flow: isopropanol fe0acd60-3ddc-11dd-a843-0050c2490048
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_species
  • Sources: wacker-silicone-processing
1,1,1,2-Tetrafluoroethane emission to air (r134a_air)

Conditional only when this actual species/outlet is established by chemistry and measurement; preserve detection limits and real control destination. Never infer its mass from total VOC, cap weight loss or total particulate. Missing critical speciation makes the concrete dataset incomplete; not a declared zero.

  • Selected flow: 1,1,1,2-Tetrafluoroethane emission to air
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_species
  • Sources: wacker-silicone-processing
Cured silicone rubber particulate to air (silicone_dust)

Conditional only when this actual species/outlet is established by chemistry and measurement; preserve detection limits and real control destination. Never infer its mass from total VOC, cap weight loss or total particulate. Missing critical speciation makes the concrete dataset incomplete; not a declared zero.

  • Selected flow: Cured silicone rubber particulate to air
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_species
  • Sources: wacker-silicone-processing
Nitrogen to external air (nitrogen_out)

Record actual gross carrier species discharged from ventilation and pneumatic use, distinguishing purchased carrier subaccounts and onsite atmospheric intake. Atmospheric carbon dioxide passing through is not new fossil CO2 generation; independently evidence any reaction or uptake and no automatic credit.

  • Selected flow: Nitrogen to external air
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_air
  • Sources: wacker-silicone-processing
Oxygen to external air (oxygen_out)

Record actual gross carrier species discharged from ventilation and pneumatic use, distinguishing purchased carrier subaccounts and onsite atmospheric intake. Atmospheric carbon dioxide passing through is not new fossil CO2 generation; independently evidence any reaction or uptake and no automatic credit.

  • Selected flow: Oxygen to external air
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_air
  • Sources: wacker-silicone-processing
Argon to external air (argon_out)

Record actual gross carrier species discharged from ventilation and pneumatic use, distinguishing purchased carrier subaccounts and onsite atmospheric intake. Atmospheric carbon dioxide passing through is not new fossil CO2 generation; independently evidence any reaction or uptake and no automatic credit.

  • Selected flow: Argon to external air
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_air
  • Sources: wacker-silicone-processing
Atmospheric-origin carbon dioxide to external air (co2_out)

Record actual gross carrier species discharged from ventilation and pneumatic use, distinguishing purchased carrier subaccounts and onsite atmospheric intake. Atmospheric carbon dioxide passing through is not new fossil CO2 generation; independently evidence any reaction or uptake and no automatic credit.

  • Selected flow: Atmospheric-origin carbon dioxide to external air
  • Flow property / unit: Mass / kg
  • Amount rule: Measured undivided raw cohort numerator; use the sole section8 reporting operation after conversion and attribution. Preserve this card scope and original unit.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_air
  • Sources: wacker-silicone-processing

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 8
Rule IDApplies toRuleSource IDs
boundary_routeall processesInclude receipt/storage, paired dosing/mixing, real cold-runner and hot-mould injection/cure, demould, actual flash/sprue trim, cleaning, conditioning/testing and unique first release. Include actual optional electric postcure, cooling, air, vacuum, maintenance, storage/packing/dispatch services and failure/idle loads. No boiler, external steam, fuel firing or peroxide reaction is presumed; changed actual operations require full single-material/species inventory and applicability review.wacker-silicone-processing, jerry-swim-cap-production
boundary_qreleased_capQ is the sum of uniquely identified NEW first-accepted complete net cap kg. Reinspection, delivery, returns, reopening or redelivery creates no new Q. Closing released FG already belongs to Q once; do not add it as an extra manufacturing output. Q=0 retains all actual loads and yields no unit result.jerry-swim-cap-production
boundary_stockall inventory rowsKeep separate raw A, raw B, mixed material in feed/mixer/runner, uncured/cured unaccepted WIP and retained tests by actual location/lot/state. Opening stock plus actual receipts/transfers equals closing stock plus actual consumption/exports/losses. For EVERY exchange carry opening inherited burden vector, add real current increments, transfer internal vectors once, retain closing vector and original denominator/history. Preserve all failed/zero-output/start-stop/idle/cleanup/rework burdens. Keep cooling-loop water, hydraulic charge, refrigerant charge and other equipment stocks with their own physical quantity AND inherited exchange vectors wherever outside raw/WIP; name locations and eliminate overlap.
boundary_fgfg_in; fg_return; fg_out; fg_power; waste_fgFG gate: openingFG + newFirstReleaseQ + externalReturnedCaps = closingFG + grossOutwardCapsG + actualFGWaste. Preserve each old FG/return cohort original production numerator, original Q and delivery reversal history. Attribute actual storage/packing/handling/dispatch and incremental rework services to that lot with its own historical denominator, never unrelated current Q. Manufacturing and FG combined gates cancel internal Q transfers; they do not add first release and closing FG twice. Future services not yet observed stay disclosed incomplete.
boundary_packall packaging rowsFor EACH separate article: opening empty + opening attachedWIP + opening attachedFG + opening reusable + new external purchase/receipt + externalReturnReceived = closing empty + closing attachedWIP + closing attachedFG + closing reusable + article accompanying gross physical dispatch + externalReturnSent + waste. Distinguish purchase from attached supplier receipts to prevent duplicate entries; track residual contents independently. All five external directions have separate cards. Internal reuse cancels and never reduces gross outward mass, raises net product Q, creates new purchase or earns automatic coproduct/avoided-burden credit. Add each genuinely used different article/material before modelling.
boundary_waterwater_makeup; wash_water; external_cooling_in; external_cooling_out; water_vapourClose physical total mass and relevant Si/C/H/O balances independently from analytical species/phase evidence at manufacturing, FG and combined gates. Separate free moisture, emulsion carrier, ambient moisture, retained water, actual evaporation/condensate/effluent and independently evidenced reaction/structural water. Addition hydrosilylation does not justify inventing water byproduct; no two unknown masses from one residual, and no species mass from COD/TVOC. External water returns remain real Product outputs with measured state/enthalpy and supplier energy/water convention; internal cooling recirculation is not purchase.wacker-silicone-processing
boundary_speciesall elementary rowsActual ventilation/pneumatic gas carries individually measured nitrogen, oxygen, argon, atmospheric-origin CO2 and water plus each genuine process species. Purchased compressed-air species are child carrier accounts, not duplicate resource intake. Quantify actual D4/D5/D6 and other siloxanes separately only if detected/otherwise evidenced; addition cure is not proof of zero volatile release. Species leaving with wastewater or waste remains in that outlet, not also emitted to air. Add each actual new species/size fraction/compartment and capture-residue destination; no unspecified VOC/PM surrogate mass.wacker-silicone-processing
boundary_qualitylsr_a; lsr_b; released_capIndependently verify matching A/B formulation, storage/pot life and inhibitor/cross-contamination controls; actual acceptance covers complete cap geometry, surface, cure and declared service tests. Compression/HCR, peroxide, textile or printed cap evidence is not an LSR production recipe. Postcure depends on actual supplier/product qualification; retain genuine postcure electricity, ventilated species and failures, never enforce a universal temperature/time from a thick-sheet chart.wacker-silicone-processing, jerry-swim-cap-production, ukong-swim-cap-supply
Allocation rules · 6
Rule IDApplies toRuleSource IDs
allocation_scopeall inventory rowsThis method uses attributional allocation only where the study situation requires allocation. Establish that scope first; industrial manufacturing sources do not authorize a consequential substitution or automatic recycling credit. Respect applicable ILCD situation/recycling provisions when a different question is asked.jrc-ilcd-2010
allocation_exclusiveall inventory rowsFirst subdivide actual distinguishable stages/lines or use evidenced virtual subdivision. Assign each whole formulation, dedicated machine meter, test, failure, cleanup, package and FG service directly to its causing lot/product when possible. Retain burden-bearing stock transfers and shared idle loads; no total-output shortcut before exclusive attribution.jrc-ilcd-2010
allocation_causalityall inventory rowsFor each still-shared exchange independently identify the determining physical cause and actual measured driver, e.g. heater duty with temperature/time/configuration, cooling duty with measured flow/enthalpy, or handling with actual operations. Mass/count alone is not universal causality. Validate each driver and allocation total/uncertainty; different exchanges may need different causal drivers.jrc-ilcd-2010
allocation_residualall inventory rowsOnly the genuine residual lacking a determining physical assignment uses relative market value of actual cofunctions at the common process exit/entry gate in their real state and period. Derive same-gate values transparently by removing later transport/conditioning/packaging costs where necessary; record quantity, currency, date and sensitivity. Unknown causal/value evidence holds that dataset incomplete; no fixed ratio or free choice between physical/economic keys.jrc-ilcd-2010
allocation_returnsall packaging rows; fg_out; fg_return; waste_fgPhysical custody remains unchanged by burden allocation. Internal reuse carries inherited burden once; external waste/recovery follows actual treatment/ownership and applicable recycling model. No automatic negative flow, avoided virgin credit or erasure of old cap production from a return, retest or lost lot.jrc-ilcd-2010
asset_manufacture_conservationexisting capital/reusable manufacture attributionWithin the applicable allocation decision context, original manufacture burden attributed across uses of actual capital equipment or reusable articles already included in foreground production, packaging or observed services uses one persistent same-asset ledger across all crops, products, cohorts, manufacturing/postrelease services, owners and observation periods. D is its supported whole installed service: all realized historical service plus supported remaining service in the same units as actual beneficiary use u; D must be finite and positive. Period capacity, remaining-only capacity, the physical asset/article mass alone, or current-period product Q alone is not D; supported whole-service throughput in mass units may be used when it demonstrates the causal service and matches u. This does not amortize the manufactured reference product over downstream life or change its declared reference gate/Q. The fractions u/D and all previously assigned manufacture shares together must never exceed 1. Changes of window, custody, provider or repair never restart the original manufacture balance. Replacements have distinct identities and only their real new manufacture vectors; actual repair and treatment increments remain separately accounted. Revised capacity evidence requires transparent reconciliation of prior shares and sensitivity, not a fresh ledger. Keep full physical mass and stock movements independent of burden shares. Unknown D, prior shares or beneficiary coverage requires review and no final manufacture-attributed amount; no assumed lifetime, utilization, zero or arbitrary division is permitted. For each existing collection protocol that attributes manufacture of included production, packaging or observed-service assets across uses in this route (excluding amortization of the manufactured reference product itself), additionally retain a durable asset identity, its measured full physical mass and acquisition/installation/retirement stock history, original manufacture burden vector, all historical and current beneficiaries, matched-unit service readings, the evidenced whole installed-service denominator D, supported remaining-service basis and uncertainty, prior assigned shares and remaining original manufacture balance. Carry the ledger across reporting windows and custody/provider changes. Collect actual repair, replacement, recovery and treatment separately; these records do not normalize physical movements or create an additional asset purchase. These are added fields and conservation obligations for the existing applicable protocols, not a new assumed capital inventory.
Validation rules · 7
Rule IDApplies toRuleSource IDs
validate_referencereleased_capRequire the actual complete unprinted nonprotective LSR cap and every qualifier; 1 kg net new first-release basis must select this sole linked reference row in both languages. Do not infer per-cap weight or let generic native headgear identity replace route evidence.jerry-swim-cap-production, ukong-swim-cap-supply, un-cpc3-2025
validate_measurementall inventory rowsVerify raw units/rates and measured state, unique Q, whole formulation count, complete stock vectors and original cohort denominators; report_once executes once only. Q=0, unsupported conversion or missing critical relationships cannot yield a passing concrete dataset.
validate_physicalall processesIndependently reconcile manufacturing, FG and combined physical mass/elements, actual species/phase data, separate water/equipment charges and every package article/direction; cancel only internal transfers. Do not solve two unknowns from one residual or erase gross dispatch through reuse/allocation.
validate_nativeall inventory rowsAdopted Product/Waste/resource/emission type, CAS, material state, particle structure, supply geography/voltage and actual compartment must agree with original native restrictions. Distinguish ordinary air from long-term/indoor/water outlets; a family name or taxonomic correction is not compatibility proof.
validate_allocationall inventory rowsDemonstrate exclusive/virtual subdivision and per-exchange determining physical cause before any genuine residual common-gate market-value allocation. Preserve exact full-period failures, zero-output and historical stock burdens; missing evidence stays explicit.jrc-ilcd-2010
validate_qualityreleased_capRequire actual geometry/visual/fit/cure and declared strength acceptance, A/B storage compatibility and real finishing/postcure evidence. No performance, certification or lifetime can be inferred from a manufacturer page or a supplier example chart.wacker-silicone-processing, jerry-swim-cap-production, ukong-swim-cap-supply
validate_asset_manufacture_conservationexisting capital/reusable manufacture attributionFor every included capital/reusable manufacture attribution verify same-asset continuity, whole installed service in matched units, all historical/current beneficiaries, prior assigned manufacture shares and cumulative share <= 1. Reject a reset by period, cohort, provider, owner or repair. Check distinct real replacement and incremental repair/treatment vectors separately and preserve gross physical mass. A missing denominator, unexplained previous allocation or incomplete beneficiary ledger requires explicit review and an unavailable final attributed amount; structural inspection cannot claim empirical completeness.
Processes and inputs/outputs · 1
Process IDProcess nameInput flowsOutput flows
cap_productionComplete cap manufacture and separately accounted actual FG services3341

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.