TianGong PCR

Gas works gas (and other manufactured gases for distribution)

Lifecycle status
Candidate
Content maturity
Authored methodology
Current version
No published versionLast updated
Readiness
Review required

Methodology and translation states come from the source record; publishing this website does not change their review status.

Content languages

zh-CN · Aligned
Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:17202 · exact

Source

1. Scope and Applicability

This PCR governs foreground data packages for gas works converting, purifying or blending feedstocks into manufactured gaseous fuel for distribution, measured at the plant delivery meter. Distribution fuel is the main gas works product, rather than a recovered steelmaking gas. Carbonisation, gasification, reforming and blending are covered; declare the actual route. The official CPC structure distinguishes gas works gas, coke oven gas and recovered gases. The IEA 2008 definition supports multiple routes; the narrower CBS coal-derived town-gas definition supports the representative subclass without restricting all routes to coal. Sources: unsd-cpc-2025, iea-gasworks-2008, cbs-town-gas.

Exclude mere natural-gas extraction or distribution, gas by-products at standalone steelmaking coke ovens, untreated blast-furnace or converter gas, synthesis gas dedicated to chemical synthesis, pure hydrogen and end-use combustion. When such gases enter gas works as feedstocks, retain their actual input identities and upstream burdens; entry into a network alone does not change their origin. Purification, gas holders, compression and plant-outlet metering belong to production here; municipal network delivery needs a separate data package.

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.ores-and-minerals-electricity-gas-and-water.electricity-town-gas-steam-and-hot-water.gas-works-gas-and-other-manufactured-gases-for-distribution
classification_refsCPC 3.0:17202
covered_productsManufactured distribution fuel gas from gas works; declared carbonisation, gasification, reforming or blending route
excluded_productsDirect natural gas supply; recovered steelworks gas; chemical synthesis gas; pure hydrogen
representative_productPurified coal-derived town gas ready for distribution
production_routeActual site-specific manufacture, purification and final mixing; do not add alternative route inventories
market_stateGaseous fuel at plant outlet; declared composition, pressure, temperature, wet/dry basis and quality acceptance

3. Reference Flow

FieldValue
WhatSupply manufactured gaseous distribution fuel
How much1 m3 accepted gas at plant outlet
How wellDeclared supply quality; composition, calorific value, impurities and interchangeability indicators
How long or cycleDeclared annual operating period including startup, shutdown and abnormal operation
reference_flow_linkreference_gas
FieldValue
Reference amount1
Reference product flowGas 084a3bc0-51e3-4c71-bd26-236efaeba2b5
Reference flow propertyVolume 93a60a56-a3c8-22da-a746-0800200c9a66
Reference unit groupUnits of volume 93a60a57-a3c8-12da-a746-0800200c9a66
Reference unitm3
Required qualifierssite; period; manufacture route; feedstocks and blend shares; delivery meter; volume reference temperature and absolute pressure; wet/dry basis; compressibility and meter correction method; composition; gross and net calorific values and test method; sulfur and tar content; delivery pressure; acceptance specification; upstream input boundaries

Declare every required qualifier in metadata, process notes or reference-flow comments. One m3 at different reference conditions is not directly comparable; provide traceable conversions, not generic heating values or densities.

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
volume_basisreference productVolumem3Use corrected delivery volume collected with cp_gas; retain traceability from metering conditions to declared reference conditions.
electricity_unitsmake_electricity; clean_electricity; export_electricityNet calorific valueMJConvert meter kWh using the unit identity 1 kWh = 3.6 MJ; preserve electricity energy rather than substitute gas heating value.
steam_qualitysteam_feedMasskgRecord steam mass and thermodynamic state; match upstream steam pressure, temperature and condensate return.
chemical_basiscaustic; iron_sorbentMasskgCollect solid sodium hydroxide mass and formulated sorbent mass. Solutions require concentration-specific flows; avoid counting solvent water twice.

5. System Boundary

Boundary Abstraction

FieldValue
declared_starting_conditionFeedstocks and incoming gases received at site with declared identity and upstream boundary
starting_condition_roleForeground production entry with accounted upstream supply
product_classification_scopeGas works manufactured distribution fuel; coke oven or recovered inputs retain their incoming category
recursive_input_ruleMeter purchased same-category gas separately and link supplier data; internal recirculation and own-gas firing stay in internal ledgers without repeated product input
upstream_dataset_requirementMatch datasets for each purchased feedstock, electricity, steam, water, chemical and external waste treatment; disclose missing supply-chain coverage
disclosureSite boundary, flowsheet, origins, upstream starting points, internal transfers, holder-stock changes, flaring, venting and excluded network delivery
rule_idapplies_torulesource_ids
boundary_operationsforegroundInclude feed preparation, actual conversion or mixing, cooling and purification, holders, final compression and metering, energy supply and abatement; select the actual route and retain startup and loss records.iea-gasworks-2008
boundary_transfersincoming_gasesFor coke oven and recovered feed gases retain supplier boundaries and burdens; record incremental gas works processing and prevent duplication of production burdens.unsd-cpc-2025; iea-gasworks-2008
boundary_internalall inventory rowsDo not repeat internal gas, water or steam circulation as external exchanges; include own-gas combustion and flare emissions. Disclose external delivery, end use and infrastructure separately; a plant-outlet inventory is not a complete life cycle.

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
makeFeed preparation and manufacture or initial mixingrequiredActual declared routeforeground production1 m3 reference gas
cleanCooling, purification and co-product separationconditionalGas needs cooling, impurity removal or co-product separationconditioning1 m3 reference gas
exportHolders, final mixing, compression and outlet meteringrequiredActual delivery conditionsconditioning1 m3 reference gas

Processes are collection groups within one integrated gas works. Record internal raw-gas transfers in the flowsheet ledger without repeating them as external exchanges. Include each row only under its stated condition; declare absent technologies not applicable instead of summing alternatives. Add an individual exchange in the data package for every additional solvent, catalyst, waste stream or emitted species actually present, with identity, amount, conditions and fate.

Process: Feed preparation and gas manufacture (make)

Inputs

Product flows
Gas coal feedstock (coal_feed)

When gas coal is carbonised or gasified; add an exact individual flow for every other coal grade used.

  • Selected flow: hard coal, gas coal ec4b882e-3ec8-4756-9689-fa8760c16811
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66; unit group Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 / kg
  • Amount rule: Use traceable measured records from cp_feed, attributed to the delivered reference flow.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_feed
  • Sources:
Gas coke (coke_feed)

When purchased gas coke is gasified; internal coke recycling is excluded from purchased input.

  • Selected flow: Gas coke
  • Flow property / unit: Mass / kg
  • Amount rule: Use traceable measured records from cp_feed, attributed to the delivered reference flow.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_feed
  • Sources:
Natural gas, gaseous (natural_gas_feed)

When natural gas is reformed or used as a blending component; identify feedstock and thermal-use shares separately.

  • Selected flow: natural gas in the gaseous state 4f19ca0e-7b3b-11dd-ad8b-0800200c9a66
  • Flow property / unit: Volume 93a60a56-a3c8-22da-a746-0800200c9a66; unit group Units of volume 93a60a57-a3c8-12da-a746-0800200c9a66 / m3
  • Amount rule: Use traceable measured records from cp_feed, attributed to the delivered reference flow.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_feed
  • Sources:
Naphtha (naphtha_feed)

When naphtha is reformed or used for enrichment.

  • Selected flow: Naphtha 91cc5451-cf5d-48c7-9dcc-b054eda6fbb0
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66; unit group Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 / kg
  • Amount rule: Use traceable measured records from cp_feed, attributed to the delivered reference flow.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_feed
  • Sources:
Liquefied petroleum gas (lpg_feed)

When propane/butane LPG is vaporised for enrichment or mixing.

  • Selected flow: Liquefied petroleum gas 3786072f-d3ce-4941-9249-ed5d346b21a6
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66; unit group Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 / kg
  • Amount rule: Use traceable measured records from cp_feed, attributed to the delivered reference flow.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_feed
  • Sources:
Residual fuel oil (oil_feed)

When residual fuel oil is gasified or used for enrichment; disclose sulfur and water content.

  • Selected flow: heavy fuel oil 9490cf0e-a790-44a1-9c2f-3793bbdb452d
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66; unit group Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 / kg
  • Amount rule: Use traceable measured records from cp_feed, attributed to the delivered reference flow.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_feed
  • Sources:
Coke oven gas (coke_oven_gas_feed)

When external coke oven gas is received for conversion into the gas works distribution product; retain its upstream burden.

  • Selected flow: coke oven gas 32ab44a2-c912-4c1f-98cf-856a24b3f99a
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66; unit group Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 / kg
  • Amount rule: Use traceable measured records from cp_feed, attributed to the delivered reference flow.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_feed
  • Sources:
Electricity (make_electricity)

This purchased electricity exchange requires independently confirmed actual supplier, consumption or production interface, geography, voltage, generation attributes and energy property/unit; its UUID remains unresolved until a compatible direct-read identity is confirmed. A waste-incineration generation flow must not represent arbitrary site power.

For metered manufacture and feed preparation electricity; separate grid imports from self-generation.

  • Selected flow: Electricity
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66; unit group Units of energy 93a60a57-a3c8-11da-a746-0800200c9a66 / MJ
  • Amount rule: Use traceable measured records from cp_energy, attributed to the delivered reference flow.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_energy
  • Sources:
Steam (steam_feed)

When external steam supplies a reactant or heat; disclose pressure, temperature and condensate return.

  • Selected flow: Steam 293f9fd9-5182-4d35-8aa5-ce73d4f322b7
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66; unit group Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 / kg
  • Amount rule: Use traceable measured records from cp_energy, attributed to the delivered reference flow.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_energy
  • Sources:
Gaseous oxygen (oxygen_feed)

When oxygen-blown gasification operates; state purity and gas reference conditions.

  • Selected flow: oxygen f804eb52-65c3-4db0-9d2d-e463b29e6e4b
  • Flow property / unit: Volume 93a60a56-a3c8-22da-a746-0800200c9a66; unit group Units of volume 93a60a57-a3c8-12da-a746-0800200c9a66 / m3
  • Amount rule: Use traceable measured records from cp_feed, attributed to the delivered reference flow.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_feed
  • Sources:
Waste flows

No scheduled exchange of this type; record actual additional exchanges individually.

Elementary flows
Air, atmospheric (air_feed)

When atmospheric air is drawn into gasification or dilution; keep this distinct from purchased oxygen.

  • Selected flow: air fe0acd60-3ddc-11dd-aaa4-0050c2490048
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66; unit group Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 / kg
  • Amount rule: Use traceable measured records from cp_feed, attributed to the delivered reference flow.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_feed
  • Sources:

Outputs

Product flows
Gas coke (gas_coke_coproduct)

When marketable gas coke leaves coal-carbonisation operations; exclude internal recycle.

  • Selected flow: Gas coke
  • Flow property / unit: Mass / kg
  • Amount rule: Use traceable measured records from cp_products, attributed to the delivered reference flow.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_products
  • Sources:
Coal tar (coal_tar_coproduct)

When separated coal tar is sold; contaminated tar sent for disposal needs a distinct waste row in the data package.

  • Selected flow: Coal tar 176de006-c7be-47ad-be03-2ce15e99c6ff
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66; unit group Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 / kg
  • Amount rule: Use traceable measured records from cp_products, attributed to the delivered reference flow.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_products
  • Sources:
Waste flows
Coal gasification ash (gasification_ash)

When ash crosses the facility boundary; record dry mass, moisture and treatment destination.

  • Selected flow: Coal gasification ash
  • Flow property / unit: Mass / kg
  • Amount rule: Use traceable measured records from cp_waste, attributed to the delivered reference flow.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_waste
  • Sources:
Elementary flows
Carbon dioxide, fossil, to air (make_co2)

For fossil carbon released by process conversion, firing and flaring, after capture; separate process and combustion records.

  • Selected flow: carbon dioxide (fossil) 08a91e70-3ddc-11dd-923d-0050c2490048
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66; unit group Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 / kg
  • Amount rule: Use traceable measured records from cp_emissions, attributed to the delivered reference flow.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_emissions
  • Sources:
Carbon monoxide, to air (make_co)

When conversion or combustion releases carbon monoxide; distinguish it from the carbon monoxide retained in product gas.

  • Selected flow: carbon monoxide (fossil) 08a91e70-3ddc-11dd-924e-0050c2490048
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66; unit group Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 / kg
  • Amount rule: Use traceable measured records from cp_emissions, attributed to the delivered reference flow.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_emissions
  • Sources:
Sulfur dioxide, to air (make_so2)

When sulfur-bearing fuels are oxidised and sulfur dioxide is emitted after abatement.

  • Selected flow: Sulfur dioxide, to air
  • Flow property / unit: Mass / kg
  • Amount rule: Use traceable measured records from cp_emissions, attributed to the delivered reference flow.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_emissions
  • Sources:
Nitrogen dioxide, to air (make_no2)

When nitrogen dioxide is emitted; obtain species-specific results instead of duplicating a total NOx result.

  • Selected flow: Nitrogen dioxide, to air
  • Flow property / unit: Mass / kg
  • Amount rule: Use traceable measured records from cp_emissions, attributed to the delivered reference flow.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_emissions
  • Sources:
Nitrogen monoxide, to air (make_no)

When nitrogen monoxide is emitted; document analytical speciation separately from nitrogen dioxide.

  • Selected flow: Nitrogen monoxide, to air
  • Flow property / unit: Mass / kg
  • Amount rule: Use traceable measured records from cp_emissions, attributed to the delivered reference flow.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_emissions
  • Sources:

Process: Gas cooling and purification (clean)

Inputs

Product flows
Electricity (clean_electricity)

This purchased electricity exchange requires independently confirmed actual supplier, consumption or production interface, geography, voltage, generation attributes and energy property/unit; its UUID remains unresolved until a compatible direct-read identity is confirmed. A waste-incineration generation flow must not represent arbitrary site power.

For pumps, gas cooling and purification; meter separately or document attribution.

  • Selected flow: Electricity
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66; unit group Units of energy 93a60a57-a3c8-11da-a746-0800200c9a66 / MJ
  • Amount rule: Use traceable measured records from cp_energy, attributed to the delivered reference flow.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_energy
  • Sources:
Process water (process_water)

When fresh supplied water enters cooling or washing; exclude repeatedly circulated internal water.

  • Selected flow: Process Water 94a04f7e-2d5c-41f0-b182-d54a3b373a02
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66; unit group Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 / kg
  • Amount rule: Use traceable measured records from cp_water, attributed to the delivered reference flow.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_water
  • Sources:
Sodium hydroxide (caustic)

When solid sodium hydroxide is dissolved for acid-gas washing; purchased solutions require their own concentration-specific flow.

  • Selected flow: Sodium hydroxide e0abcced-0611-4c24-9290-5a2c5a0c4169
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66; unit group Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 / kg
  • Amount rule: Use traceable measured records from cp_chemicals, attributed to the delivered reference flow.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_chemicals
  • Sources:
Iron oxide desulfurisation sorbent (iron_sorbent)

When iron-oxide-based dry desulfurisation is used; record actual formulation rather than pure-oxide equivalents.

  • Selected flow: Iron oxide desulfurisation sorbent
  • Flow property / unit: Mass / kg
  • Amount rule: Use traceable measured records from cp_chemicals, attributed to the delivered reference flow.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_chemicals
  • Sources:
Waste flows

No scheduled exchange of this type; record actual additional exchanges individually.

Elementary flows

No scheduled exchange of this type; record actual additional exchanges individually.

Outputs

Product flows
Recovered sulfur (recovered_sulfur)

When crude recovered elemental sulfur is a saleable product.

  • Selected flow: Recovered elemental sulphur, crude 586e1b09-2904-4b0a-b1ef-fc012259004f
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66; unit group Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 / kg
  • Amount rule: Use traceable measured records from cp_products, attributed to the delivered reference flow.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_products
  • Sources:
Waste flows
Gas-washing wastewater (gas_liquor)

When contaminated gas-washing liquor is exported to treatment; onsite treatment requires separate discharge and sludge records in the data package.

  • Selected flow: Gas-washing wastewater
  • Flow property / unit: Mass / kg
  • Amount rule: Use traceable measured records from cp_waste, attributed to the delivered reference flow.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_waste
  • Sources:
Spent iron oxide desulfurisation sorbent (spent_sorbent)

When exhausted sorbent leaves the site; record sulfur loading, moisture and hazardous-waste classification.

  • Selected flow: Spent iron oxide desulfurisation sorbent
  • Flow property / unit: Mass / kg
  • Amount rule: Use traceable measured records from cp_waste, attributed to the delivered reference flow.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_waste
  • Sources:
Elementary flows
Hydrogen sulfide, to air (clean_h2s)

When hydrogen sulfide escapes washing or sulfur recovery; product sulfur content is not an emission.

  • Selected flow: hydrogen sulfide 08a91e70-3ddc-11dd-94a9-0050c2490048
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66; unit group Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 / kg
  • Amount rule: Use traceable measured records from cp_emissions, attributed to the delivered reference flow.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_emissions
  • Sources:

Process: Conditioning and outlet delivery (export)

Inputs

Product flows
Electricity (export_electricity)

This purchased electricity exchange requires independently confirmed actual supplier, consumption or production interface, geography, voltage, generation attributes and energy property/unit; its UUID remains unresolved until a compatible direct-read identity is confirmed. A waste-incineration generation flow must not represent arbitrary site power.

For final blending, compression, holders and outlet metering inside the site boundary.

  • Selected flow: Electricity
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66; unit group Units of energy 93a60a57-a3c8-11da-a746-0800200c9a66 / MJ
  • Amount rule: Use traceable measured records from cp_energy, attributed to the delivered reference flow.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_energy
  • Sources:
Waste flows

No scheduled exchange of this type; record actual additional exchanges individually.

Elementary flows

No scheduled exchange of this type; record actual additional exchanges individually.

Outputs

Product flows
Gas works gas (reference_gas)

Accepted distribution-ready gas at the plant outlet; exclude rejected gas, internal fuel use and recirculation.

  • Selected flow: Gas 084a3bc0-51e3-4c71-bd26-236efaeba2b5
  • Flow property / unit: Volume 93a60a56-a3c8-22da-a746-0800200c9a66; unit group Units of volume 93a60a57-a3c8-12da-a746-0800200c9a66 / m3
  • Amount rule: 1 m3
  • Value mode: Fixed value (fixed_value)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Source rule (source_rule)
  • Collection protocol: cp_gas
  • Sources: iea-gasworks-2008
Waste flows

No scheduled exchange of this type; record actual additional exchanges individually.

Elementary flows
Methane, fossil, to air (handling_methane)

For fugitive and vented methane from all gas-handling stages; reconcile equipment registers to avoid overlap with flares.

  • Selected flow: Methane, fossil, to air
  • Flow property / unit: Mass / kg
  • Amount rule: Use traceable measured records from cp_emissions, attributed to the delivered reference flow.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_emissions
  • Sources:
Carbon monoxide, to air (handling_co)

For carbon monoxide lost by venting and leaks from gas handling; keep separate from make_co combustion emissions.

  • Selected flow: carbon monoxide (fossil) 08a91e70-3ddc-11dd-924e-0050c2490048
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66; unit group Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 / kg
  • Amount rule: Use traceable measured records from cp_emissions, attributed to the delivered reference flow.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_emissions
  • Sources:

7. Allocation and Co-product Handling

rule_idapplies_torulesource_ids
allocation_avoidjoint operationsPrefer subdivision and independent metering to avoid allocation. Use system expansion only in a separate study declaring all expanded functions; do not combine allocation and substitution credits in a single-product supply dataset.ec-pef-2021
allocation_physicalgas; coke; tar; sulfurWhere subdivision is unavailable, document a defensible physical causal relationship with all co-products and parameters. Energy allocation needs evidence of fuel functions and a common gross/net calorific basis; never add gas volume and solid mass as an allocation basis.ec-pef-2021
allocation_otherjoint operationsIf a physical relationship cannot be supported, justify rejecting preceding methods and use relative economic value at a common period and market point if appropriate. Disclose prices, quantities, shares and sensitivity. Keep waste-treatment burdens with the generating process rather than treat disposal mass as co-product value.ec-pef-2021

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_gasexportreference productmeter and operating recordsoutlet volume; T; absolute P; wet/dry basis; correction factors; stock; composition; calorific values; acceptance certificateCalibrated flow meter and quality testing; retain the actual correction equations and method edition and recompute delivered quantities on common conditions.m3shift records with monthly reconciliationcomplete declared operating yearsame site and routeper reference flowcalibration, tests, transfer notes and ledgers
cp_feedmakefeedstockmeter and operating recordsmaterial receipts; stock; internal recycle; feedstock/thermal use; composition and moisture; gas metering conditionsWeighing, supplier records or gas meters; reconcile net external use with opening/closing stock and internal transfers.kg; m3shift records with monthly reconciliationcomplete declared operating yearsame site and routeper reference flowcalibration, tests, transfer notes and ledgers
cp_energymake; clean; exportelectricity; steammeter and operating recordsprocess electricity; steam mass and state; condensate return; own energy; purchased energyCollect submeter electricity and steam mass; document attribution where submeters are unavailable and express electricity in MJ.MJ; kgshift records with monthly reconciliationcomplete declared operating yearsame site and routeper reference flowcalibration, tests, transfer notes and ledgers
cp_watercleanfresh supplied watermeter and operating recordswater mass; makeup; circulation; discharge; evaporation; meter errorUse mass measurement or volume with measured density to reconcile new supplied water; do not repeat internal circulation.kgshift records with monthly reconciliationcomplete declared operating yearsame site and routeper reference flowcalibration, tests, transfer notes and ledgers
cp_chemicalscleanindividual chemicalmeter and operating recordsformulation; concentration; net consumption; stock; supplier; sorbent sulfur loadingWeigh each chemical and reconcile purchases, withdrawals and stock; create distinct flows for different solution concentrations.kgshift records with monthly reconciliationcomplete declared operating yearsame site and routeper reference flowcalibration, tests, transfer notes and ledgers
cp_productsmake; cleanindividual co-productmeter and operating recordsco-product mass; moisture; specification; fate; price; calorific valueWeigh and reconcile sales and stock; distinguish accepted sales, recycle and disposal.kgshift records with monthly reconciliationcomplete declared operating yearsame site and routeper reference flowcalibration, tests, transfer notes and ledgers
cp_wastemake; cleanindividual wastemeter and operating recordswaste mass; moisture; hazard classification; composition; transfer note; treatment operatorWeigh each waste and reconcile transfer notes; use measured density for liquids and disclose treatment boundaries.kgshift records with monthly reconciliationcomplete declared operating yearsame site and routeper reference flowcalibration, tests, transfer notes and ledgers
cp_emissionsmake; clean; exportindividual emitted substancemeter and operating recordsrelease point; species; concentration; flow; time; detection limit; leaks; flares; captureDetermine each substance from monitoring, material balance or documented engineering estimates; retain all inputs and uncertainty, not product-gas composition as an emitted amount.kgshift records with monthly reconciliationcomplete declared operating yearsame site and routeper reference flowcalibration, tests, transfer notes and ledgers

Every protocol uses net accepted delivered volume from the same period as denominator. Divide each attributable period exchange by net delivered gas volume at the same declared reference conditions to obtain its quantity per 1 m3 reference flow. Fixed output 1 m3 is a normalization definition, not a measured yield. Reconcile stock changes, own fuel and losses in internal ledgers without both subtracting them from delivery and repeating them as purchased gas.

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
period_normalizationall inventory rowsUse the collection normalization stated above, attributable period total divided by net delivered volume; retain both unallocated totals and allocated quantities.cp_gas; cp_feed; cp_energy; cp_water; cp_chemicals; cp_products; cp_waste; cp_emissionsexchange amount per reference flow
electricity_conversionmake_electricity; clean_electricity; export_electricity1 kWh = 3.6 MJ; dimensional unit identity.cp_energyMJ electricity per reference flow

Data Quality Requirements

requirement_idApplies toRequirementEvidence
route_qualityforegroundRetain actual flowsheet, all external exchanges, internal transfers and reasons for non-applicability; add atomic rows for additional materials and emissions.flowsheet and ledgers
volume_qualityreference_gasAlign conditions for delivery, incoming gas meters, holder stock and calorific values; prohibit comparison where conversion is not traceable.cp_gas; cp_feed
emission_qualitycp_emissionsDisclose monitoring coverage, detection limits, unmeasured species and estimate error; a total NOx measurement cannot be assigned in full to both NO and NO2.monitoring and analytical records
range_qualityall inventory rowsCollect actual quantities. This PCR supplies no generic inferred ranges or default emission factors; missing records are not zero. Engineering estimates in the data package must be marked modelled_estimate with justification and uncertainty.collection protocols and gap disclosure

9. Validation Rules

rule_idapplies_torulesource_ids
validate_identityreference_gasCheck route, delivery state, all required qualifiers and gas conditions; mere natural-gas distribution is outside scope.unsd-cpc-2025; iea-gasworks-2008
validate_measurementall inventory rowsEach row must agree with the same-period, same-condition 1 m3 accepted outlet gas; check properties, units, upstream compatibility, electricity conversion and steam state.
validate_balanceforegroundReconcile carbon, sulfur and energy ledgers with consistent moisture, stock and blend composition; do not repeat material inputs after converting them to energy. Explain non-closure by measurement or coverage evidence without invented tolerances.
validate_allocationjoint operationsCheck same-period co-products, method selection, prices or physical parameters and all shares; do not duplicate burdens across supplier inputs, internal circulation and site manufacture.ec-pef-2021
validate_completenessforegroundExpose unresolved UUIDs and identity, emitted-species, treatment and upstream-coverage gaps. Retain collection requirements where range evidence is insufficient; one case is not an industry range.

10. Published Dataset Profile

FieldValue
dataset_roleforeground_dataset
downstream_usesecondary_dataset; background_dataset
allowed_useGas works supply modelling at compatible product state and volume conditions; input to process or lifecyclemodel projections
excluded_useComplete delivery and combustion life cycle; natural gas extraction; pure hydrogen or chemical synthesis gas; cross-route comparisons without conversion
required_metadataall reference qualifiers; origins and upstream boundaries; flowsheet; allocation; internal transfers and stock; treatment destinations
required_quality_disclosureUUID and range gaps; estimates; monitoring coverage and errors; missing supply chains; excluded infrastructure, delivery and end-use stages
update_triggermaterial changes in feedstocks, route, supply quality, abatement, metering conditions or allocation market

11. Data Sources

Source idTypeReferenceUsed for
unsd-cpc-2025official_guidanceUN Statistics Division, CPC Version 3.0 structure, 30 June 2025. https://unstats.un.org/unsd/classifications/Econ/Download/In%20Text/CPC_Ver_3.0_Structure_30Jun2025.csvclassification identity, cells 17200–17203; original CSV verified, accessed 2026-10-01.
iea-gasworks-2008official_guidanceOECD/IEA, InterEnerStat: Harmonisation of Definitions of Energy Products and Flows, Products: Coal (2008), PDF pages 17–20. https://iea.blob.core.windows.net/assets/imports/events/39/Coal.pdfroute scope, gas coke and coke oven gas distinction; historical definition supplies no current efficiency, emission factor or quality standard. Accessed 2026-10-01.
cbs-town-gasofficial_guidanceStatistics Netherlands (CBS), Gas works gas definition. https://www.cbs.nl/en-gb/our-services/methods/definitions/gas-works-gasrepresentative coal-derived town gas and scope comparison; narrower than IEA multi-route category. Accessed 2026-10-01.
ec-pef-2021official_guidanceCommission Recommendation (EU) 2021/2279, consolidated 30 December 2021, Annex I section 4.5, PDF pages 87–88. https://eur-lex.europa.eu/legal-content/EN/TXT/PDF/?uri=CELEX%3A02021H2279-20211230general multifunctional allocation hierarchy; methodological guidance, not a gas-specific factor or PEF conformance claim. Accessed 2026-10-01.

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 3
Rule IDApplies toRuleSource IDs
boundary_operationsforegroundInclude feed preparation, actual conversion or mixing, cooling and purification, holders, final compression and metering, energy supply and abatement; select the actual route and retain startup and loss records.iea-gasworks-2008
boundary_transfersincoming_gasesFor coke oven and recovered feed gases retain supplier boundaries and burdens; record incremental gas works processing and prevent duplication of production burdens.unsd-cpc-2025, iea-gasworks-2008
boundary_internalall inventory rowsDo not repeat internal gas, water or steam circulation as external exchanges; include own-gas combustion and flare emissions. Disclose external delivery, end use and infrastructure separately; a plant-outlet inventory is not a complete life cycle.
Allocation rules · 3
Rule IDApplies toRuleSource IDs
allocation_avoidjoint operationsPrefer subdivision and independent metering to avoid allocation. Use system expansion only in a separate study declaring all expanded functions; do not combine allocation and substitution credits in a single-product supply dataset.ec-pef-2021
allocation_physicalgas; coke; tar; sulfurWhere subdivision is unavailable, document a defensible physical causal relationship with all co-products and parameters. Energy allocation needs evidence of fuel functions and a common gross/net calorific basis; never add gas volume and solid mass as an allocation basis.ec-pef-2021
allocation_otherjoint operationsIf a physical relationship cannot be supported, justify rejecting preceding methods and use relative economic value at a common period and market point if appropriate. Disclose prices, quantities, shares and sensitivity. Keep waste-treatment burdens with the generating process rather than treat disposal mass as co-product value.ec-pef-2021
Validation rules · 5
Rule IDApplies toRuleSource IDs
validate_identityreference_gasCheck route, delivery state, all required qualifiers and gas conditions; mere natural-gas distribution is outside scope.unsd-cpc-2025, iea-gasworks-2008
validate_measurementall inventory rowsEach row must agree with the same-period, same-condition 1 m3 accepted outlet gas; check properties, units, upstream compatibility, electricity conversion and steam state.
validate_balanceforegroundReconcile carbon, sulfur and energy ledgers with consistent moisture, stock and blend composition; do not repeat material inputs after converting them to energy. Explain non-closure by measurement or coverage evidence without invented tolerances.
validate_allocationjoint operationsCheck same-period co-products, method selection, prices or physical parameters and all shares; do not duplicate burdens across supplier inputs, internal circulation and site manufacture.ec-pef-2021
validate_completenessforegroundExpose unresolved UUIDs and identity, emitted-species, treatment and upstream-coverage gaps. Retain collection requirements where range evidence is insufficient; one case is not an industry range.
Processes and inputs/outputs · 3
Process IDProcess nameInput flowsOutput flows
makeFeed preparation and manufacture or initial mixing118
cleanCooling, purification and co-product separation44
exportHolders, final mixing, compression and outlet metering13

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page