TianGong PCR

Special-purpose machinery n.e.c. (including machinery for isotopic separation, machines for assembling electric lamps in glass envelopes, machines for manufacturing glassware and rope making machines)

Lifecycle status
Candidate
Content maturity
Authored methodology
Current version
No published versionLast updated
Readiness
Review required

Methodology and translation states come from the source record; publishing this website does not change their review status.

Content languages

en-US · canonicalzh-CN · Aligned
Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:44930 · exact

Source

1. Scope and Applicability

This PCR develops manufacturing foreground data for complete special-purpose machinery n.e.c., preserving all explicitly named families: isotopic separation; assembling electric lamps/tubes/flashbulbs in glass envelopes; manufacturing or hot-working glass/glassware, including optical fibres/preforms and other glass; and making ropes or cables. Other residual machines require an actual principal-function review demonstrating no more-specific product category. CPC defines the full subclass; the retained Schedule B headings and note clarify functions, not alternative canonical identities.

SKLOSTROJ ISS documents servo-driven feeder/section/plunger architectures, an optional pneumatic plunger, conveyor, central lubrication, cooling and electrical distribution; its factory describes precision CNC/NC/conventional component manufacture and assembly. Servo versus pneumatic options and catalogue weight including moulds/conveyors/platforms cannot establish a default configured net mass or material recipe.

Grenzebach supplies float-glass tin-bath equipment with roof/casing/heaters/top rollers/cameras/cooling and utility interfaces. Xinniu fibre-drawing equipment describes a cast-iron turntable, high-strength aluminium head, bearings, direct or belt motor drive and PLC/DCS cabinets. Actual supplied alloy/finish and retained fill require their own proof. Glass-fibre machinery is not automatically optical-fibre machinery. Cold-end cutting and independent furnaces/utilities need separate function review. Customer molten tin, glass, fibre or gas recipes do not become equipment BOM.

The historical LRI brochure describes modular lamp-forming/mounting/jacket-sealing/exhaust equipment, factory machining and electrical assembly, and installation/operation before dispatch for debugging. Its historical readable observations support architecture and actual factory qualification; missing/corrupted text, catalogue lamp rates and customer lamp materials do not establish a current machine recipe. Each integrated machine or independent module needs supplied completion and principal-function review.

POURTIER explicitly describes steel-rope, submarine/control/umbilical cable stranding and armouring. Pioneer describes copper/aluminium/steel-wire stranding, bearing supports, oil-circulation pump/tank, optional band or hysteresis braking, independent AC servomotors and PLC/HMI. Rope/cable making may strand, twist or cable metal wire, textile yarn or combinations, but HERZOG explicitly also covers textile braiding: no complete HERZOG braider or its similar steel/rubber components proves this subclass. Textile lace/gimped-yarn machines require their own category review.

ETC public manufacturer evidence establishes supply/manufacture/installation of isotope-separation equipment and associated pipework/support services. This PCR uses only public supply and manufacturing LCA boundaries, measured materials/energy and accepted hardware; it does not prescribe separation operating design, enrichment conditions or process optimisation. Generic group carbon-fibre manufacturing capability is not evidence of every isotope machine construction. Independent support equipment and services are not automatically physical reference mass.

Reference output is 1 kg of calibrated accepted net physical machine of one declared configuration. Record actual cohort Dnet/Naccepted/M, purchased complete modules versus own manufacture, observed factory tests, actual retained supplied fills/accessories and transport packing separately. Consumed/rejected customer-type trial glass/envelopes/yarn/wire/fuel are manufacturing Qattr only when actually used in factory qualification, never Dnet. Retained first fill requires shipment evidence, not tank capacity. Stand-alone parts, general-purpose drives/pumps/control units, ordinary utility furnaces, customer glass/lamps/ropes and production services are not this finished reference; hybrid and whole-line modules require actual principal-function and physical-boundary review.

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.metal-products-machinery-and-equipment.special-purpose-machinery.special-purpose-machinery-n-e-c-including-machinery-for-isotopic-separation-machines-fo-66e15395
classification_refsCPC3.0 44930
covered_productsComplete isotopic-separation, glass-envelope lamp assembly, glass manufacture, rope/cable-making and actual reviewed residual machines n.e.c.
excluded_productsIndependent parts/general-purpose/utility furnaces/cold-glass-working/unclassified textile braiders/customer glass-lamp-rope products and services
representative_productActual complete accepted special-purpose machine of one supplied configuration
production_routeActual component manufacture or bought completion; mechanical/thermal/electrical/control integration; observed factory qualification/packing
market_stateComplete accepted supply; actual hardware and proven retained fills/accessories

3. Reference Flow

FieldValue
WhatActual declared configuration of complete accepted special-purpose machinery n.e.c.
How much1 kg accepted net physical output
How wellActual principal function/supplied completion/acceptance requirements; no default catalogue mass
How long or cycleManufacture through cohort accepted release; observed factory qualification, no customer lifetime recipe
reference_flow_linkreference_product
FieldValue
Reference amount1
Reference product flowComplete accepted special-purpose machinery n.e.c.
Reference flow propertyMass 93a60a56-a3c8-11da-a746-0800200b9a66
Reference unit groupUnits of mass 93a60a57-a4c8-11da-a746-0800200c9a66
Reference unitkg
Required qualifiersmodel/revision/size/serial cohort; full actual family and principal function; actual glass/lamp/rope-cable/isotope or reviewed residual scope; mechanical/thermal/control architecture; each complete supply/make-buy interface; installed retained fill species/state/quantity; excluded test consumption/rejects/packing/services/independent equipment; calibrated Dnet/Naccepted/M and common period; actual provider/geography/voltage; own assays/stocks/returns

Declare every required qualifier in dataset metadata or equivalent notes; missing qualifiers make the reference incomplete.

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
reference_massreference productMasskgM = accepted net mass of one complete unit of the same configuration in kg; collect using cp_mass.
native_numeratorall inventory rowsactual native reference propertykg; MJ; m; m3Preserve each native numerator; q_ref=q_item/M. Cable m uses own same-construction kg/m, hydraulic-oil m3 measured liquid-temperature density, compressed-gas m3 own absolute T/P/wet-dry density for physical balances only. No power/capacity-to-mass conversion. Additional solid volume needs own solid geometry/same-grade density, not gas T/P.
energy_conversionelectricity and actual heatEnergyMJElectricity kWh×3.6; actual matched voltage/geography. Supply/return heat own mass/enthalpy/common datum, gross/net return once; not rated power/customer production energy/supplier boiler fuel.

5. System Boundary

Boundary Abstraction

FieldValue
declared_starting_conditionActual external feedstock/completed components at factory by actual supply completion
starting_condition_roleforeground_start
product_classification_scopeComplete four explicit families and reviewed residual special-purpose machinery; independent parts/utilities/adjacent functions separately reviewed
recursive_input_ruleComplete bought input embeds upstream once; site-made actual inputs/operations; pair/cancel internal transfers
upstream_dataset_requirementActual matched supply completion/grade/formulation/geography/period/treatment
disclosureManufacturing foreground; incomplete upstream forbids complete cradle-to-gate footprint claim
rule_idApplies toRulesource_ids
gateforegroundInclude actual machine-component receipt/fabrication/finish, mechanical/thermal/control integration, observed factory qualification, attributable rejects/rework, packing/wastes/common services through accepted release.
make_buysupplier_interfaceEach retained module/component chooses actual bought completion versus own manufacture. Bought complete engine/housing/PCB/module includes upstream materials/processes once; site-made instead records separately measured queried raw inputs and site operations. Pair and cancel internal transfers.
factory_useproductionActual factory electrical/mechanical/thermal/alignment functional trials are manufacturing burden, not customer glass/lamp/rope production or separation service. Measured trial feedstock, rejects/rework/recovery/stocks outside Dnet; retained actual hardware/fills only with accepted shipment proof. Independent utility furnaces, cold-glass machines or general handling equipment not automatically machine mass, even in a marketed bundle.
bom_extensionrouteConditional atomic cards are not a universal BOM. Each actual missing alloy/polymer grade, abrasive/blast medium, release agent, coolant/refrigerant, gas, drive/control/heating part, retained accessory/fill, trial formulation, waste or emitted species requires its own bounded directed identity query and independent measurement. Unknown differs from zero/not_applicable; absence needs evidence.
upstreamlinksMatch actual supplied completion, grade/formulation, geography/voltage/period and external treatment route. Actual special-purpose principal function and complete machine versus intermediate module or independent ancillary require individual review. Missing upstream forbids full footprint claim.

Actual architecture and supplied variants

variantactual_configurationscope_condition
Isotopic separationPublic complete equipment supply/manufacture only; actual accepted configurationNo operating-design/optimisation recipes or group-capability-to-BOM assumption
Glass-envelope lamp assemblyActual forming/mounting/sealing/exhaust supplied completion and integrated functionHistorical LRI evidence conditional; customer lamp feed not equipment BOM
Glass manufactureActual hot glass/float/container/fibre and optical/preform function reviewedCold working44221 and independent utility equipment separate
Rope/cable makingActual stranding/twisting/cabling metal wire/textile yarn/combinationsPOURTIER/Pioneer support actual cable/steel rope; HERZOG textile braiding taxonomy unconfirmed
Residual and hybridOther actual complete special-purpose machine only with no more-specific categoryActual principal function and independent line modules reviewed individually

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
fabricationActual structural and component fabricationconditionalActual casting/machining/welding/finishing or operations after bought completed inputs; own verified material grades onlyforegroundper 1 kg reference flow
assemblyConfigured mechanical, thermal and control integrationrequiredActual retained drive, fluid, heating, electrical and control hardware, actual supplied configuration and make/buy interfacesforegroundper 1 kg reference flow
qualificationObserved factory qualificationrequiredActual alignment, electrical/mechanical/leak tests and observed functional trials; rejects/rework attributable, customer production excludedforegroundper 1 kg reference flow
dispatchAccepted configured machine release and packingrequiredActual complete accepted hardware configuration and proven retained fills; packing separately measured outside net outputforegroundper 1 kg reference flow
servicesUnassigned common manufacturing servicesconditionalOnly reconciled unassigned same-period energy/water residual after subprocess attributionforegroundper 1 kg reference flow

Process: Actual structural and component fabrication (fabrication)

Actual casting/machining/welding/finishing or operations after bought completed inputs; own verified material grades only.

Inputs

Product flows
Hot-rolled non-alloy steel coil (steel)

Actual BF hot-rolled NON-alloy coil, thickness2–7mm/width600–2100mm, supplied compatible steelmaking/rolling interface; not any structural plate, stainless steel or cast iron. Own received grade/cut stock/returns/installed mass.

  • Selected flow: steel hot rolled coil 4f1a1835-7b3b-11dd-ad8b-0800200c9a66
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Alloy steel bars for machined parts (steel_bar)

Actual hot-forged/rolled/drawn/extruded alloy steel bar under41244, excluding high-speed or silicomanganese steel; own grade/completion, not reinforcement bar or any metal.

  • Selected flow: Bars and rods of alloy steel, not further worked than forged, hot-rolled, hot-drawn or extruded (except bars or rods of high-speed steel or silico-manganese steel) c11c7e9a-d020-4b89-a50c-4a82c0f76943
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Stainless steel sheet (stainless)

Only actual separately measured supplied stainless steel sheet with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity.

  • Selected flow: Stainless steel sheet
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Structural aluminium profile (aluminium_profile)

Actual42190 prepared structural extruded aluminium profile, own alloy/temper/finish and installed/cut stock; not Xinniu cast aluminium head, unwrought metal or assumed6063.

  • Selected flow: Aluminium Profile d7de8999-a129-4f8b-8d6e-8856d87c470c
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: sklostroj-manufacture
Machined cast-iron base blank (cast_iron)

Only actual separately measured supplied machined cast-iron base blank with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity.

  • Selected flow: Machined cast-iron base blank
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: xinniu-fibre
Self-shielded carbon-steel welding wire (welding)

Actual completed self-shielded all-position single-pass carbon-steel flux-cored wire, own sheath/flux/grade and compatible route; not generic MIG solid wire. Any actual shielding gas requires an additional independent queried/measured row.

  • Selected flow: Flux Cored Wire 1b74a576-06e0-4764-97ce-11a73f8a4752
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Water-miscible metalworking fluid concentrate (cutting_fluid)

Only actual separately measured supplied water-miscible metalworking fluid concentrate with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity.

  • Selected flow: Cutting Fluid 576d250f-4f36-4385-939d-0f03b8f95a10
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Polyester powder coating compound (powder_coat)

Actual completed formulated powder coating under35110; use only with supplier-confirmed polyester resin/additives/colour/cure state matching this row. No generic polymer powder, fixed resin recipe or powder coating on every machine.

  • Selected flow: Powder Coating 6e3010f9-fbd3-48f6-95fc-c1b38d2800d2
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Process water (water)

Only actual separately measured supplied process water with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity.

  • Selected flow: Process Water 94a04f7e-2d5c-41f0-b182-d54a3b373a02
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Artificial corundum abrasive grains (abrasive)

Actual finished artificial-corundum abrasive grains under37960, own particle grade/assay and measured blasting/finishing recovery; not chemical alumina or customer glass composition.

  • Selected flow: Artificial corundum a6e3c50f-7479-4004-9825-dc60fb6e696d
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Electricity (fabrication_electricity)

Only actual CN user-side 1–35kV electricity delivery matching provider, voltage and period; not every geography. Native Energy/MJ, actual kWh converted by 3.6; process loads and common unassigned residual reconcile with imports, generation, exports and stocks, no rated-power-times-default-hours.

  • Selected flow: Alternating current 3d76981f-964a-4865-b588-0e067a2a1163
  • Flow property / unit: Delivered energy / MJ
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_energy.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_energy
  • Sources:
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Steel machining offcuts (steel_scrap)

Actual measured outgoing steel machining offcuts only: own species/assay/formulation, water fraction/contamination/state, transfer/stocks, paired internal returns and actual external receiver/treatment. Separate captured solvent and non-air fates; no fresh input, air residual or default recycling credit. Actual untreated steel offcuts39340, own assay/moisture/receiver; no universal credit.

  • Selected flow: Steel scrap, offcuts ae44c4ac-bcd5-4a16-b0a5-d674ffeaab6b
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_waste.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_waste
  • Sources:
Aluminium offcuts (al_scrap)

Actual measured outgoing aluminium offcuts only: own species/assay/formulation, water fraction/contamination/state, transfer/stocks, paired internal returns and actual external receiver/treatment. Separate captured solvent and non-air fates; no fresh input, air residual or default recycling credit. Actual cast/contaminated aluminium39363 and processing/recycling receiver must match.

  • Selected flow: Aluminium Scrap 96c5f842-ea53-419b-b1cd-c02c479efb45
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_waste.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_waste
  • Sources:
Spent metalworking oil (oil_waste)

Actual measured outgoing spent metalworking oil only: own species/assay/formulation, water fraction/contamination/state, transfer/stocks, paired internal returns and actual external receiver/treatment. Separate captured solvent and non-air fates; no fresh input, air residual or default recycling credit. The dataset comment1% is not a quantity factor.

  • Selected flow: Waste cutting oil 80d926e3-0f76-4a19-9b1e-ffec9deb1216
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_waste.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_waste
  • Sources:
Metal-cleaning wastewater sent for treatment (effluent)

Actual measured outgoing metal-cleaning wastewater sent for treatment only: own species/assay/formulation, water fraction/contamination/state, transfer/stocks, paired internal returns and actual external receiver/treatment. Separate captured solvent and non-air fates; no fresh input, air residual or default recycling credit.

  • Selected flow: Metal-cleaning wastewater sent for treatment
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_waste.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_waste
  • Sources:
Waste polyester coating powder (coating_waste)

Actual measured outgoing waste polyester coating powder only: own species/assay/formulation, water fraction/contamination/state, transfer/stocks, paired internal returns and actual external receiver/treatment. Separate captured solvent and non-air fates; no fresh input, air residual or default recycling credit.

  • Selected flow: Powder coating waste 9aa53a82-5462-400e-9096-efab7718201f
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_waste.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_waste
  • Sources:
Elementary flows

Process: Configured mechanical, thermal and control integration (assembly)

Actual retained drive, fluid, heating, electrical and control hardware, actual supplied configuration and make/buy interfaces.

Inputs

Product flows
AC servomotor (motor)

Only actual separately measured supplied ac servomotor with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity.

  • Selected flow: Electric drive, servo motor 89a4fdf2-5cce-4df3-b372-14407f92dd28
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: pioneer-strander; sklostroj-iss
Ball or roller bearing (bearing)

Only actual separately measured supplied ball or roller bearing with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity.

  • Selected flow: Ball or roller bearings 9b10184f-db9d-4cc7-94b5-02ab19ca370d
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: pioneer-strander; xinniu-fibre
Complete industrial reduction gearbox (gearbox)

Only actual separately measured supplied complete industrial reduction gearbox with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity.

  • Selected flow: Complete industrial reduction gearbox
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Complete lubricating-oil liquid pump (pump)

Actual complete liquid lubricating-oil pump with own compatible technology/model and provider; not vacuum pump, hydraulic service or generic rated capacity. Bought completed pump includes internal manufacture once.

  • Selected flow: Pump bbd91be4-dc00-44c2-8bc1-f67ee79174a7
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: pioneer-strander
Complete vacuum pump (vacuum_pump)

Only actual separately measured supplied complete vacuum pump with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity.

  • Selected flow: Air or vacuum pumps, air or other gas compressors 7c9988b6-d0cf-4a08-801a-097d31f374d7
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Complete pneumatic cylinder (pneumatic)

Only actual separately measured supplied complete pneumatic cylinder with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity.

  • Selected flow: Complete pneumatic cylinder
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: sklostroj-iss
Complete programmable logic controller (plc)

Only actual separately measured supplied complete programmable logic controller with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity.

  • Selected flow: Complete programmable logic controller
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: pioneer-strander; xinniu-fibre
Electrical heating resistor (heater)

Actual complete non-carbon electrical heating resistor under44818 with matched supplier element/construction, not carbon resistor, lamp, whole furnace or conversion from wattage to mass.

  • Selected flow: Electric heating resistors, except of carbon 991da6ee-1a8a-4e77-8f9c-c50615e255e7
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: grenzebach-glass
Complete industrial gas burner (burner)

Actual complete industrial gas burner under43410 with verified fuel/technology/supply completion; not pre-finishing/QA intermediate burner subassembly or whole furnace. Actual factory test fuel separately measured, no catalogue burner rate.

  • Selected flow: Furnace burners for liquid fuel, for pulverized solid fuel or for gas, mechanical stokers, mechanical grates, mechanical ash dischargers and similar appliances 25b61b3f-31a8-4618-9025-db11814c43e2
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Vulcanized NBR rubber sealing element (seal)

Actual completed vulcanized NBR sealing element under36270 with supplier formulation/fit; not all PTFE/TPU/metal seals or unspecified rubber.

  • Selected flow: Sealing elements a9943e4e-1a21-412c-859e-df09a2b5ee6f
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Steel screw (fastener)

Only actual separately measured supplied steel screw with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity.

  • Selected flow: Steel screw 895204f6-6425-4814-afc5-cb97e530e892
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Vulcanized rubber hose (hose)

Actual completed vulcanized-rubber hose under36230 with own reinforcement/construction/fluid/pressure compatibility; not TPU hose, metal pipe or every air/water tube.

  • Selected flow: Hydraulic hose e2fc1719-69dc-4281-8eae-383af8d9a405
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Insulated copper power cable (cable)

Actual completed0.6/1kV Cu/Al power cable under GB/T12706.1-2020 and supplier construction, not generic flex/signal cord. Native Length/m measured installed/cut/returned/stocks; own same-construction measured kg/m for physical balance only, no electrical-rating conversion.

  • Selected flow: Low-voltage cable 49101b44-20cc-46a0-adfb-af07e4cc8908
  • Flow property / unit: Length / m
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_length.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_length
  • Sources:
Furfural re-refined mineral lubricating oil (lubricant)

Actual furfural re-refined mineral lubricating oil from used oil, with supplier-confirmed refinery route, composition, viscosity and phase. A compatible finished-oil identity is not confirmed; a solvent CAS or PAO synthetic oil is not a substitute. Measure retained charge, factory consumption, returns and stocks separately; a bought charged module embeds its upstream fill once.

  • Selected flow: Furfural re-refined mineral lubricating oil
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: pioneer-strander; sklostroj-iss
Hydraulic oil (hydraulic_oil)

Actual petroleum-based hydraulic oil with≥70% petroleum oil basis, supplier grade/phase matching; native liquid Volume/m3. Measure actual liquid volume and corresponding temperature/own density for physical kg reconciliation, not gas T/P or bulk void volume. Retained/consumed/stocks separately tracked.

  • Selected flow: Hydraulic Fluid 30691a38-a947-4b41-991e-194f6c9aa88f
  • Flow property / unit: Volume / m3
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_liquid.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_liquid
  • Sources: pioneer-strander
Electricity (assembly_electricity)

Only actual CN user-side 1–35kV electricity delivery matching provider, voltage and period; not every geography. Native Energy/MJ, actual kWh converted by 3.6; process loads and common unassigned residual reconcile with imports, generation, exports and stocks, no rated-power-times-default-hours.

  • Selected flow: Alternating current 3d76981f-964a-4865-b588-0e067a2a1163
  • Flow property / unit: Delivered energy / MJ
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_energy.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_energy
  • Sources:
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Elementary flows

Process: Observed factory qualification (qualification)

Actual alignment, electrical/mechanical/leak tests and observed functional trials; rejects/rework attributable, customer production excluded.

Inputs

Product flows
Soda-lime glass gob for observed factory test (test_glass)

Only actual separately measured supplied soda-lime glass gob for observed factory test with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity.

  • Selected flow: Soda-lime glass gob for observed factory test
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Empty glass lamp envelope for observed factory assembly test (test_bulb)

Only actual separately measured supplied empty glass lamp envelope for observed factory assembly test with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity.

  • Selected flow: Empty glass lamp envelope for observed factory assembly test
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Polyester multifilament yarn for observed rope test (test_yarn)

Actual PET continuous filament yarn CAS25038-59-9, not sewing/multiple/cabled or retail yarn, with verified multifilament construction and actual rope/cable host function. Actual observed factory test only; issued/returned/stocks/assay separately measured, consumed yarn outside Dnet. HERZOG textile brochure alone does not prove this host or test.

  • Selected flow: Polyester Filament 30173859-61d4-4518-ba9e-6846b8491c1b
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Copper wire for observed stranding test (test_copper)

Actual bare drawn copper wire under41513 with own grade/purity/diameter/supply interface and measured observed factory stranding trials/returns/stocks. Not wire rod, solder or insulated power cable; consumed wire not Dnet.

  • Selected flow: copper wire 4f197beb-7b3b-11dd-ad8b-0800200c9a66
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Gaseous oxygen (oxygen)

Actual gaseous air-separation O2, verified purity/provider/phase, separately measured kg in observed factory thermal qualification only. No catalogue customer glass combustion recipe, liquid O2 or unpublished/mixed gas substitute.

  • Selected flow: oxygen 4f19ca15-7b3b-11dd-ad8b-0800200c9a66
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Natural gas (natural_gas)

Actual observed factory thermal-test fuel, own composition/phase/interface/assay and calibrated mass; no compatible published identity confirmed. Native volume if actual supplier interface requires its own absolute T/P/wet-dry/standard basis and matched density/calorific basis; no generic LNG or unpublished substitute.

  • Selected flow: Natural gas
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Gaseous nitrogen (nitrogen)

Actual gaseous N2 air-separation supply matching purity/provider/phase/pressure, separately measured kg; actual factory trial or shipment-proven retained charge only. Property mean1.25 is not density or quantity factor. No customer float-bath recipe or assumed isotope working gas.

  • Selected flow: Nitrogen 67bb2ea6-2fd8-43c5-b227-bca12040b773
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Process water (water_test)

Only actual separately measured supplied process water with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity.

  • Selected flow: Process Water 94a04f7e-2d5c-41f0-b182-d54a3b373a02
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Isopropanol cleaning solvent (ipa)

Actual CN chemical isopropanol at plant with verified supplied assay/formulation, not a cleaning mixture inferred pure. Independent issue, retained product, recovered/captured liquid or media, wastewater and actual species air release use their own assays/stocks; unknown residual never becomes air.

  • Selected flow: Isopropanol a4a75541-e156-4e30-947c-ba067a682afd
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Compressed air (compressed_air)

Actual supplied compressed air, native Volume/m3 at declared absolute pressure/temperature and wet/dry or standard conditions; own corresponding density for physical mass only. Purchased import versus own compressor generation reconciled without double import+electricity burden.

  • Selected flow: Compressed air 46e2b1e4-5a4e-4579-b6a2-65b03f9ce825
  • Flow property / unit: Volume / m3
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_gas.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_gas
  • Sources:
Electricity (qualification_electricity)

Only actual CN user-side 1–35kV electricity delivery matching provider, voltage and period; not every geography. Native Energy/MJ, actual kWh converted by 3.6; process loads and common unassigned residual reconcile with imports, generation, exports and stocks, no rated-power-times-default-hours.

  • Selected flow: Alternating current 3d76981f-964a-4865-b588-0e067a2a1163
  • Flow property / unit: Delivered energy / MJ
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_energy.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_energy
  • Sources:
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Waste glass test pieces (glass_waste)

Actual measured outgoing waste glass test pieces only: own species/assay/formulation, water fraction/contamination/state, transfer/stocks, paired internal returns and actual external receiver/treatment. Separate captured solvent and non-air fates; no fresh input, air residual or default recycling credit.

  • Selected flow: Waste glass test pieces
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_waste.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_waste
  • Sources:
Waste polyester test yarn (yarn_waste)

Actual measured outgoing waste polyester test yarn only: own species/assay/formulation, water fraction/contamination/state, transfer/stocks, paired internal returns and actual external receiver/treatment. Separate captured solvent and non-air fates; no fresh input, air residual or default recycling credit.

  • Selected flow: Waste polyester test yarn
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_waste.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_waste
  • Sources:
Copper wire test scrap (copper_waste)

Actual measured outgoing copper wire test scrap only: own species/assay/formulation, water fraction/contamination/state, transfer/stocks, paired internal returns and actual external receiver/treatment. Separate captured solvent and non-air fates; no fresh input, air residual or default recycling credit.

  • Selected flow: Copper wire test scrap
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_waste.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_waste
  • Sources:
Spent isopropanol cleaning solvent (solvent_waste)

Actual measured outgoing spent isopropanol cleaning solvent only: own species/assay/formulation, water fraction/contamination/state, transfer/stocks, paired internal returns and actual external receiver/treatment. Separate captured solvent and non-air fates; no fresh input, air residual or default recycling credit.

  • Selected flow: Spent isopropanol cleaning solvent
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_waste.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_waste
  • Sources:
Elementary flows
Carbon dioxide fossil (co2)

Only independently measured carbon dioxide fossil to ordinary unspecified air with matched species/origin: post-control species concentration times same-period gas flow/time and actual T/P/wet-dry/unit basis plus measured fugitives, or demonstrated species balance including all non-air fates. Capture not destruction; unknown residual not air.

  • Selected flow: carbon dioxide (fossil) 08a91e70-3ddc-11dd-923d-0050c2490048
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_emission.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_emission
  • Sources:
Carbon monoxide fossil (co)

Only independently measured carbon monoxide fossil to ordinary unspecified air with matched species/origin: post-control species concentration times same-period gas flow/time and actual T/P/wet-dry/unit basis plus measured fugitives, or demonstrated species balance including all non-air fates. Capture not destruction; unknown residual not air.

  • Selected flow: carbon monoxide (fossil) 08a91e70-3ddc-11dd-924e-0050c2490048
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_emission.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_emission
  • Sources:
Isopropanol to air (ipa_air)

Only independently measured isopropanol to air to ordinary unspecified air with matched species/origin: post-control species concentration times same-period gas flow/time and actual T/P/wet-dry/unit basis plus measured fugitives, or demonstrated species balance including all non-air fates. Capture not destruction; unknown residual not air.

  • Selected flow: isopropanol fe0acd60-3ddc-11dd-a843-0050c2490048
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_emission.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_emission
  • Sources:
Water vapour to air (vapour)

Only independently measured water vapour to air to ordinary unspecified air with matched species/origin: post-control species concentration times same-period gas flow/time and actual T/P/wet-dry/unit basis plus measured fugitives, or demonstrated species balance including all non-air fates. Capture not destruction; unknown residual not air.

  • Selected flow: water vapour fe0acd60-3ddc-11dd-ac04-0050c2490048
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_emission.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_emission
  • Sources:
Particulate matter PM10 to air (dust)

Only independently measured particulate matter pm10 to air to ordinary unspecified air with matched species/origin: post-control species concentration times same-period gas flow/time and actual T/P/wet-dry/unit basis plus measured fugitives, or demonstrated species balance including all non-air fates. Capture not destruction; unknown residual not air.

  • Selected flow: particles (PM10) 08a91e70-3ddc-11dd-91be-0050c2490048
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_emission.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_emission
  • Sources:

Process: Accepted configured machine release and packing (dispatch)

Actual complete accepted hardware configuration and proven retained fills; packing separately measured outside net output.

Inputs

Product flows
Corrugated paperboard packing sheet (cardboard)

Actual corrugated C/E/F paperboard sheet under32151 with cellulose fibre≥80% and actual own recycled share;≥80% does not mean recycled content. Sheet distinct from completed carton32153, each actual packing net mass measured.

  • Selected flow: Corrugated cardboard 8bde297e-98df-463f-bcb4-0db52bf6e0b5
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
LDPE packaging film (film)

Actual non-self-adhesive, non-cellular, non-reinforced, non-laminated unsupported LDPE film under36330, own formulation/thickness/pack mass; not generic plastic, PVAc or wrong film identity.

  • Selected flow: Low-density polyethylene foil (PE-LD) 2cecd3a7-d90e-44b4-aec5-1d9dfb907477
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Wooden EURO pallet (pallet)

Only actual separately measured supplied wooden euro pallet with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity.

  • Selected flow: Wooden pallet (EURO) 96b2b9ac-cfb6-46bf-8ad1-c056e338950a
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Waste flows
Elementary flows

Outputs

Product flows
Complete accepted special-purpose machinery n.e.c. (reference_product)

Selected complete accepted configuration includes actual retained fills/accessories, excluding packaging and rejects.

  • Selected flow: Complete accepted special-purpose machinery n.e.c.
  • Flow property / unit: Mass / kg
  • Amount rule: 1 kg
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_mass
  • Sources: un-cpc-44930; census-special
Waste flows
Elementary flows

Process: Unassigned common manufacturing services (services)

Only reconciled unassigned same-period energy/water residual after subprocess attribution.

Inputs

Product flows
Electricity (electricity)

Only actual CN user-side 1–35kV electricity delivery matching provider, voltage and period; not every geography. Native Energy/MJ, actual kWh converted by 3.6; process loads and common unassigned residual reconcile with imports, generation, exports and stocks, no rated-power-times-default-hours.

  • Selected flow: Alternating current 3d76981f-964a-4865-b588-0e067a2a1163
  • Flow property / unit: Delivered energy / MJ
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_energy.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_energy
  • Sources:
Purchased heat (heat)

Actual CN natural-gas district/industrial heat only with matching delivery provider and Gross calorific value Energy/MJ interface; no onsite supplier boiler fuel invented. Each steam supply/return uses own measured kg and MJ/kg common datum, deduct return once; already-net supply never double deducted.

  • Selected flow: Heat, district or industrial, natural gas eb581eb3-c707-41a0-b4e6-ee1854551714
  • Flow property / unit: Delivered energy / MJ
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_energy.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_energy
  • Sources:
Tap water (tap_water)

Only actual separately measured supplied tap water with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity.

  • Selected flow: Tap water d1e0e36c-07f0-4a75-bdcb-efb5d9e2ac36
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources:
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Elementary flows

7. Allocation and Co-product Handling

rule_idApplies toRulesource_ids
causalsiteSeparate configurations and subdivisions first; allocate common residual by measured causal load, operating time or appropriate physical driver, retain numerator and denominator records and uncertainty. Do not average unrelated machining functions or different supplied configurations or use machine mass automatically for every utility.
rejectsacceptedInclude actual rejects, rework and qualification burdens in attributable Q for accepted output; only accepted net mass/count enters denominator. Segregate recycling transfer and treatment; do not assume avoided-product credits or zero upstream recycled burden.

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_massdispatchreference productweighingmodel; configuration; serial number; accepted net mass MWeigh the accepted complete unit on a calibrated scale, excluding transport packaging; reconcile the same configuration and acceptance record.kgeach accepted lotcommon manufacturing periodsame configuration/siteaccepted net mass per unitcalibration/tare/included accessories/acceptance
cp_materialallactual inputsmeter_issuespecific species/grade; supplied state; issue; each moisture/density/assay; make/buy; stocks; Q; NReconcile each exchange metering/stores/recipe and paired returns in common period; Q includes rejects/rework and each term own assay.kgeach batch or continuous metercommon manufacturing periodsame configuration/site and supplierattributable quantity / accepted unitsgrade/composition tests/meters/stocks
cp_energyallelectricity and heatmeterprocess meters; gross imports; actual generation; exports; storage; each supply/return steam mass pressure temperature enthalpy; net invoice; Q; NReconcile process meters in same period/units; shared services only unassigned residual, investigate negative residual. Each steam supply/return uses own kg and MJ/kg/common zero, return deducted once.MJcontinuous meters/each testcommon manufacturing periodsame configuration/siteattributable energy / accepted unitscalibrated meters/delivery interface/thermodynamics/allocation uncertainty
cp_wasteallspecific wastetransfereach stream mass and own moisture/assay; beginning/end stocks; internal return; external treatment; Q; NWeigh/sample treatment transfers, distinguish return/reuse/recycling/disposal without assumed substitution credit.kgeach transfer lotcommon manufacturing periodsame configuration/site and treatment interfaceattributable waste / accepted unitswaste tickets/sampling/stocks
cp_emissionallspecific species/compartmentspecies_measurementactual species/compartment; concentration; exhaust or liquid flow; wet/dry temperature/pressure; capture/destruction; own assays; Q; NUse matched species/compartment measured or verified actual technology factors; investigate closure, capture not destruction, residual not air emission.kgactual tests/emission periodscommon manufacturing periodsame configuration/site boundaryattributable emission / accepted unitssampling/flow/combined uncertainty
cp_gasallspecific supplied gasmetercompressed-air identity; delivered volume; actual T/P or standard conditions; density; Q; NMeter compressed-air volume at actual state; mass conversion uses corresponding measured density, not a generic gas factor.m3each batch/continuous metercommon manufacturing periodsame configuration/supply interfaceattributable volume / accepted unitsT/P/flow/density/calibration
cp_lengthassemblyspecific native-length cablelength_measurementcable construction; conductor/insulation; supplier; issued/cut/installed/returned length; own kg/m; Q; NMeasure actual matching cable length, paired returns and stocks; same-construction measured kg/m only for physical mass balance. Native m retained, never infer mass from electrical rating.meach installation lotcommon manufacturing periodsame component configuration/site and supplierattributable length / accepted unitsconstruction/length/stock/mass records
cp_liquidassemblyspecific supplied liquidvolume_measurementliquid grade/phase; actual volume/temperature; own density; stocks/retained/consumed/returns; Q; NMeasure actual liquid volume and corresponding supplier-grade density at measured temperature; native m3 retained, only own density converts physical mass. Not gas T/P or bulk void volume.m3each fill/transfer lotcommon manufacturing periodsame liquid supply interfaceattributable volume / accepted unitsactual liquid temperature/volume/density/stocks

Raw-period protocol: N is accepted count of the same configuration, D the sum of calibrated accepted net masses, M=D/N. Each Q is the attributable common-period exchange including reject, rework and factory-test burden; first q_item=Q/N then q_ref=Q/D. Packaging/reject mass stays out of D. Retain actual original units, own composition, stocks and reaction records.

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
normalize_massall inventory rowsq_ref = q_item / M; q_item = exchange amount per one accepted finished unit; q_ref = exchange amount per 1 kg reference flow.q_item; M; cp_massq_ref

Data Quality Requirements

requirement_idApplies toRequirementEvidence
complete_bomactual configurationCover all actual exchanges; separate make/buy/accessories/fills/test charges; gaps explicitactual BOM/routes/suppliers
supplied_reference_configactual special-purpose configurationAccepted complete machine has actual isotope-separation, glass-envelope-lamp assembly, glass manufacture or rope/cable function; other residual only with no more-specific category. Declare principal function/model/size/serial cohort, mechanical/thermal/control architecture, completed supply and each installed physical interface. Dnet calibrated accepted hardware and proven retained fill only; packing/reject/consumed trial media/software/services excluded. No catalogue netmass.actual function/shipment/calibrated net weighing
mass_periodcohortSame configuration/period/acceptance, calibrated mass/stocks; no cross-family meancalibration/period ledger
balance_uncertaintyphysical balancesOwn water fraction/density/assay/reactions/paired returns; compare combined uncertaintymeasurement/sampling/reaction/allocation evidence
cohort_rawcohortNaccepted, Dnet and Qattr share configuration/period. Dnet sums calibrated accepted net masses; M=Dnet/Naccepted, q_item=Qattr/Naccepted, q_ref=Qattr/Dnet. Qattr includes rejects/rework/factory tests; Dnet excludes packing/rejects/consumed trial charge. Preserve each native numerator unit.calibration/actual-period ledgers
species_samplingemissionsPost-control species concentration times matched same-period gas/liquid flow and duration with T/P/wet-dry/unit corrections; fugitives independently measured. Unknown residual not air release, capture not destruction; each metal/chemical/water term uses own assay/water fraction/density/stocks/reactions/paired returns.actual concentration/flow/period/state records
contained_assayphysical balancesEach input/product/scrap/sludge/liquid/release uses own measured gross mass times own assay and wet/dry basis; gross alloy/sludge is not contained metal. Every water term uses own water fraction and density at actual temperature, including product retention/reaction/evaporation/discharge/beginning-end stocks; internal returns pair/cancel.term-specific measurement/assay/moisture/stocks
solvent_fatessolvent recordsRecord recovered return/product retention/captured liquid or media/demonstrated destruction/wastewater separately. Recovered/retained/captured and wastewater/media are non-air fates; capture not destruction. Investigate unknown residual, never turn it into air release.actual material/sampling/abatement records
utility_residualenergyReconcile common-period imports plus actual generation minus exports/storage changes against fabrication/finish/integration/test/dispatch loads; shared row ONLY unassigned residual. Investigate negative residual against period/units/combined uncertainty without clipping.calibrated subprocess/site meters
heat_returnthermal interfaceGross heat equals measured supply kg times own MJ/kg minus independently measured return kg times return own MJ/kg, with common datum and actual T/P. Gross supply deducts return once; already-net bill never deducts again. Physical steam/condensate mass separate from heat; supplier boiler fuel not onsite combustion.separate supply/return metering/thermodynamic state/invoice
dust_overlapactual particulate releasesPM10 is measured gross particulate mass of the specified size fraction. When actually present, independently measure contained crystalline silica or another species; that contained mass is not additional gross particulate mass. Each actual species needs its own identity and measurement row; declare LCIA reporting conventions and prevent repeated full characterization of the same release, without inventing silica release.actual test-media species/size-fraction sampling and LCIA reporting convention
machine_architectureactual reference objectPreserve all four explicit machine families and reviewed residual functions, not just hot-glass equipment. SKLOSTROJ servo/pneumatic variants, LRI modular lamp equipment, Grenzebach float hardware, Xinniu glass-fibre equipment and POURTIER/Pioneer stranding are actual conditional architectures. HERZOG rope/textile braiding is an adjacent classification counterexample, not proof of44930 or a default BOM. Independent cold-glass/utility/general-purpose machines and44949 parts require their own boundary; hybrids actual principal function.un-cpc-44930; census-special; actual manufacturer function
test_install_rolesactual factory recordsOwn measured factory test media include trial glass/envelope/yarn/wire/gas/fuel only when actually used for this cohort, with issue/recovery/stocks/cured state and waste or non-air fate separately measured; no catalogue recipe. None of consumed or rejected specimens enters Dnet. Retained first fill/included consumable requires actual accepted shipment/physical state/quantity evidence, not tank capacity. Bought charged module already includes its upstream charge once.actual trial/acceptance/retained shipment/stock records
provider_gapslinksEach actual upstream/treatment matches state/geography/period; unverified not complete footprintdirect records/substitution disclosure

PM10 is measured gross particulate mass of the specified size fraction; a separately measured contained chemical species is not additional gross particulate mass. Add each actual species according to tested medium and release, declare LCIA reporting conventions and prevent repeated full characterization.

requirement_idApplies toRequirementEvidence
optical_acceptanceactual technical evidenceETC public supply/manufacture evidence supports only manufacturing LCA boundaries and actual measured materials/energy, not separation operating design/optimisation or a universal carbon-fibre recipe. Glass-machine rated power/catalogue mass/utility flow, rope reel counts, customer recipes and historical lamp rates are not factory quantities. Optional servo/pneumatic, direct/belt drives and braking architectures require actual configuration. Only measured actual factory trials contribute Qattr; retained supplied fills/accessories require shipment proof.actual source-limited function/drawings/supplier completion/factory records

Supplied identity and native measurement conditions

requirement_idApplies toRequirementEvidence
qualified_steelsteelActual BF hot-rolled NON-alloy coil, thickness2–7mm/width600–2100mm, supplied compatible steelmaking/rolling interface; not any structural plate, stainless steel or cast iron. Own received grade/cut stock/returns/installed mass. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_steel_barsteel_barActual hot-forged/rolled/drawn/extruded alloy steel bar under41244, excluding high-speed or silicomanganese steel; own grade/completion, not reinforcement bar or any metal. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_aluminium_profilealuminium_profileActual42190 prepared structural extruded aluminium profile, own alloy/temper/finish and installed/cut stock; not Xinniu cast aluminium head, unwrought metal or assumed6063. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_weldingweldingActual completed self-shielded all-position single-pass carbon-steel flux-cored wire, own sheath/flux/grade and compatible route; not generic MIG solid wire. Any actual shielding gas requires an additional independent queried/measured row. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_cutting_fluidcutting_fluidOnly actual separately measured supplied water-miscible metalworking fluid concentrate with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_waterwaterOnly actual separately measured supplied process water with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_abrasiveabrasiveActual finished artificial-corundum abrasive grains under37960, own particle grade/assay and measured blasting/finishing recovery; not chemical alumina or customer glass composition. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_steel_scrapsteel_scrapActual measured outgoing steel machining offcuts only: own species/assay/formulation, water fraction/contamination/state, transfer/stocks, paired internal returns and actual external receiver/treatment. Separate captured solvent and non-air fates; no fresh input, air residual or default recycling credit. Actual untreated steel offcuts39340, own assay/moisture/receiver; no universal credit. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_al_scrapal_scrapActual measured outgoing aluminium offcuts only: own species/assay/formulation, water fraction/contamination/state, transfer/stocks, paired internal returns and actual external receiver/treatment. Separate captured solvent and non-air fates; no fresh input, air residual or default recycling credit. Actual cast/contaminated aluminium39363 and processing/recycling receiver must match. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_oil_wasteoil_wasteActual measured outgoing spent metalworking oil only: own species/assay/formulation, water fraction/contamination/state, transfer/stocks, paired internal returns and actual external receiver/treatment. Separate captured solvent and non-air fates; no fresh input, air residual or default recycling credit. The dataset comment1% is not a quantity factor. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_coating_wastecoating_wasteActual measured outgoing waste polyester coating powder only: own species/assay/formulation, water fraction/contamination/state, transfer/stocks, paired internal returns and actual external receiver/treatment. Separate captured solvent and non-air fates; no fresh input, air residual or default recycling credit. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_motormotorOnly actual separately measured supplied ac servomotor with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_bearingbearingOnly actual separately measured supplied ball or roller bearing with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_pumppumpActual complete liquid lubricating-oil pump with own compatible technology/model and provider; not vacuum pump, hydraulic service or generic rated capacity. Bought completed pump includes internal manufacture once. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_vacuum_pumpvacuum_pumpOnly actual separately measured supplied complete vacuum pump with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_heaterheaterActual complete non-carbon electrical heating resistor under44818 with matched supplier element/construction, not carbon resistor, lamp, whole furnace or conversion from wattage to mass. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_burnerburnerActual complete industrial gas burner under43410 with verified fuel/technology/supply completion; not pre-finishing/QA intermediate burner subassembly or whole furnace. Actual factory test fuel separately measured, no catalogue burner rate. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_sealsealActual completed vulcanized NBR sealing element under36270 with supplier formulation/fit; not all PTFE/TPU/metal seals or unspecified rubber. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_fastenerfastenerOnly actual separately measured supplied steel screw with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_hosehoseActual completed vulcanized-rubber hose under36230 with own reinforcement/construction/fluid/pressure compatibility; not TPU hose, metal pipe or every air/water tube. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_cablecableActual completed0.6/1kV Cu/Al power cable under GB/T12706.1-2020 and supplier construction, not generic flex/signal cord. Native Length/m measured installed/cut/returned/stocks; own same-construction measured kg/m for physical balance only, no electrical-rating conversion. Native property/unit group: 838aaa23-0117-11db-92e3-0800200c9a66; 838aaa22-0117-11db-92e3-0800200c9a66supplier specification/actual native metering
qualified_hydraulic_oilhydraulic_oilActual petroleum-based hydraulic oil with≥70% petroleum oil basis, supplier grade/phase matching; native liquid Volume/m3. Measure actual liquid volume and corresponding temperature/own density for physical kg reconciliation, not gas T/P or bulk void volume. Retained/consumed/stocks separately tracked. Native property/unit group: 93a60a56-a3c8-22da-a746-0800200c9a66; 93a60a57-a3c8-12da-a746-0800200c9a66supplier specification/actual native metering
unconfirmed_lubricantlubricantActual furfural re-refined mineral lubricating oil from used oil, with supplier-confirmed refinery route, composition, viscosity and phase. A compatible finished-oil identity is not confirmed; a solvent CAS or PAO synthetic oil is not a substitute. Measure retained charge, factory consumption, returns and stocks separately; a bought charged module embeds its upstream fill once. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_test_yarntest_yarnActual PET continuous filament yarn CAS25038-59-9, not sewing/multiple/cabled or retail yarn, with verified multifilament construction and actual rope/cable host function. Actual observed factory test only; issued/returned/stocks/assay separately measured, consumed yarn outside Dnet. HERZOG textile brochure alone does not prove this host or test. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_test_coppertest_copperActual bare drawn copper wire under41513 with own grade/purity/diameter/supply interface and measured observed factory stranding trials/returns/stocks. Not wire rod, solder or insulated power cable; consumed wire not Dnet. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_nitrogennitrogenActual gaseous N2 air-separation supply matching purity/provider/phase/pressure, separately measured kg; actual factory trial or shipment-proven retained charge only. Property mean1.25 is not density or quantity factor. No customer float-bath recipe or assumed isotope working gas. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_oxygenoxygenActual gaseous air-separation O2, verified purity/provider/phase, separately measured kg in observed factory thermal qualification only. No catalogue customer glass combustion recipe, liquid O2 or unpublished/mixed gas substitute. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_ipaipaActual CN chemical isopropanol at plant with verified supplied assay/formulation, not a cleaning mixture inferred pure. Independent issue, retained product, recovered/captured liquid or media, wastewater and actual species air release use their own assays/stocks; unknown residual never becomes air. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_compressed_aircompressed_airActual supplied compressed air, native Volume/m3 at declared absolute pressure/temperature and wet/dry or standard conditions; own corresponding density for physical mass only. Purchased import versus own compressor generation reconciled without double import+electricity burden. Native property/unit group: 93a60a56-a3c8-22da-a746-0800200c9a66; 93a60a57-a3c8-12da-a746-0800200c9a66supplier specification/actual native metering
qualified_co2co2Only independently measured carbon dioxide fossil to ordinary unspecified air with matched species/origin: post-control species concentration times same-period gas flow/time and actual T/P/wet-dry/unit basis plus measured fugitives, or demonstrated species balance including all non-air fates. Capture not destruction; unknown residual not air. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_cocoOnly independently measured carbon monoxide fossil to ordinary unspecified air with matched species/origin: post-control species concentration times same-period gas flow/time and actual T/P/wet-dry/unit basis plus measured fugitives, or demonstrated species balance including all non-air fates. Capture not destruction; unknown residual not air. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_ipa_airipa_airOnly independently measured isopropanol to air to ordinary unspecified air with matched species/origin: post-control species concentration times same-period gas flow/time and actual T/P/wet-dry/unit basis plus measured fugitives, or demonstrated species balance including all non-air fates. Capture not destruction; unknown residual not air. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_vapourvapourOnly independently measured water vapour to air to ordinary unspecified air with matched species/origin: post-control species concentration times same-period gas flow/time and actual T/P/wet-dry/unit basis plus measured fugitives, or demonstrated species balance including all non-air fates. Capture not destruction; unknown residual not air. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_dustdustOnly independently measured particulate matter pm10 to air to ordinary unspecified air with matched species/origin: post-control species concentration times same-period gas flow/time and actual T/P/wet-dry/unit basis plus measured fugitives, or demonstrated species balance including all non-air fates. Capture not destruction; unknown residual not air. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_cardboardcardboardActual corrugated C/E/F paperboard sheet under32151 with cellulose fibre≥80% and actual own recycled share;≥80% does not mean recycled content. Sheet distinct from completed carton32153, each actual packing net mass measured. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_filmfilmActual non-self-adhesive, non-cellular, non-reinforced, non-laminated unsupported LDPE film under36330, own formulation/thickness/pack mass; not generic plastic, PVAc or wrong film identity. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_palletpalletOnly actual separately measured supplied wooden euro pallet with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_electricityelectricityOnly actual CN user-side 1–35kV electricity delivery matching provider, voltage and period; not every geography. Native Energy/MJ, actual kWh converted by 3.6; process loads and common unassigned residual reconcile with imports, generation, exports and stocks, no rated-power-times-default-hours. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200c9a66; 93a60a57-a3c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_heatheatActual CN natural-gas district/industrial heat only with matching delivery provider and Gross calorific value Energy/MJ interface; no onsite supplier boiler fuel invented. Each steam supply/return uses own measured kg and MJ/kg common datum, deduct return once; already-net supply never double deducted. Native property/unit group: 93a60a56-a3c8-14da-a746-0800200c9a66; 93a60a57-a3c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_tap_watertap_waterOnly actual separately measured supplied tap water with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_powder_coatpowder_coatActual completed formulated powder coating under35110; use only with supplier-confirmed polyester resin/additives/colour/cure state matching this row. No generic polymer powder, fixed resin recipe or powder coating on every machine. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_water_testwater_testOnly actual separately measured supplied process water with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity. Native property/unit group: 93a60a56-a3c8-11da-a746-0800200b9a66; 93a60a57-a4c8-11da-a746-0800200c9a66supplier specification/actual native metering
qualified_fabrication_electricityfabrication_electricityOnly actual CN user-side 1–35kV electricity delivery matching provider, voltage and period; not every geography. Native Energy/MJ, actual kWh converted by 3.6; process loads and common unassigned residual reconcile with imports, generation, exports and stocks, no rated-power-times-default-hours.matched delivery interface/submeter records
qualified_assembly_electricityassembly_electricityOnly actual CN user-side 1–35kV electricity delivery matching provider, voltage and period; not every geography. Native Energy/MJ, actual kWh converted by 3.6; process loads and common unassigned residual reconcile with imports, generation, exports and stocks, no rated-power-times-default-hours.matched delivery interface/submeter records
qualified_qualification_electricityqualification_electricityOnly actual CN user-side 1–35kV electricity delivery matching provider, voltage and period; not every geography. Native Energy/MJ, actual kWh converted by 3.6; process loads and common unassigned residual reconcile with imports, generation, exports and stocks, no rated-power-times-default-hours.matched delivery interface/submeter records
outgoing_effluenteffluentActual measured outgoing metal-cleaning wastewater sent for treatment only: own species/assay/formulation, water fraction/contamination/state, transfer/stocks, paired internal returns and actual external receiver/treatment. Separate captured solvent and non-air fates; no fresh input, air residual or default recycling credit.sampling/weighing/stocks/actual receiver tickets
outgoing_glass_wasteglass_wasteActual measured outgoing waste glass test pieces only: own species/assay/formulation, water fraction/contamination/state, transfer/stocks, paired internal returns and actual external receiver/treatment. Separate captured solvent and non-air fates; no fresh input, air residual or default recycling credit.sampling/weighing/stocks/actual receiver tickets
outgoing_yarn_wasteyarn_wasteActual measured outgoing waste polyester test yarn only: own species/assay/formulation, water fraction/contamination/state, transfer/stocks, paired internal returns and actual external receiver/treatment. Separate captured solvent and non-air fates; no fresh input, air residual or default recycling credit.sampling/weighing/stocks/actual receiver tickets
outgoing_copper_wastecopper_wasteActual measured outgoing copper wire test scrap only: own species/assay/formulation, water fraction/contamination/state, transfer/stocks, paired internal returns and actual external receiver/treatment. Separate captured solvent and non-air fates; no fresh input, air residual or default recycling credit.sampling/weighing/stocks/actual receiver tickets
outgoing_solvent_wastesolvent_wasteActual measured outgoing spent isopropanol cleaning solvent only: own species/assay/formulation, water fraction/contamination/state, transfer/stocks, paired internal returns and actual external receiver/treatment. Separate captured solvent and non-air fates; no fresh input, air residual or default recycling credit.sampling/weighing/stocks/actual receiver tickets
requirement_idApplies toRequirementEvidence
unconfirmed_stainlessstainlessOnly actual separately measured supplied stainless steel sheet with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity.own supplied-state/specification/measurement
unconfirmed_cast_ironcast_ironOnly actual separately measured supplied machined cast-iron base blank with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity.own supplied-state/specification/measurement
unconfirmed_gearboxgearboxOnly actual separately measured supplied complete industrial reduction gearbox with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity.own supplied-state/specification/measurement
unconfirmed_pneumaticpneumaticOnly actual separately measured supplied complete pneumatic cylinder with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity.own supplied-state/specification/measurement
unconfirmed_plcplcOnly actual separately measured supplied complete programmable logic controller with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity.own supplied-state/specification/measurement
unconfirmed_test_glasstest_glassOnly actual separately measured supplied soda-lime glass gob for observed factory test with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity.own supplied-state/specification/measurement
unconfirmed_test_bulbtest_bulbOnly actual separately measured supplied empty glass lamp envelope for observed factory assembly test with verified specific grade/formulation, completion, model fit and provider. Complete bought component embeds upstream manufacture once; own fabrication instead requires independently queried actual raw inputs/operations. Source architecture is not proof of any grade or universal quantity.own supplied-state/specification/measurement
unconfirmed_natural_gasnatural_gasActual observed factory thermal-test fuel, own composition/phase/interface/assay and calibrated mass; no compatible published identity confirmed. Native volume if actual supplier interface requires its own absolute T/P/wet-dry/standard basis and matched density/calorific basis; no generic LNG or unpublished substitute.own supplied-state/specification/measurement
unconfirmed_reference_productreference_productReference output is 1 kg of calibrated accepted net physical machine of one declared configuration. Record actual cohort Dnet/Naccepted/M, purchased complete modules versus own manufacture, observed factory tests, actual retained supplied fills/accessories and transport packing separately. Consumed/rejected customer-type trial glass/envelopes/yarn/wire/fuel are manufacturing Qattr only when actually used in factory qualification, never Dnet. Retained first fill requires shipment evidence, not tank capacity. Stand-alone parts, general-purpose drives/pumps/control units, ordinary utility furnaces, customer glass/lamps/ropes and production services are not this finished reference; hybrid and whole-line modules require actual principal-function and physical-boundary review.own supplied-state/specification/measurement

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 5
Rule IDApplies toRuleSource IDs
gateforegroundInclude actual machine-component receipt/fabrication/finish, mechanical/thermal/control integration, observed factory qualification, attributable rejects/rework, packing/wastes/common services through accepted release.
make_buysupplier_interfaceEach retained module/component chooses actual bought completion versus own manufacture. Bought complete engine/housing/PCB/module includes upstream materials/processes once; site-made instead records separately measured queried raw inputs and site operations. Pair and cancel internal transfers.
factory_useproductionActual factory electrical/mechanical/thermal/alignment functional trials are manufacturing burden, not customer glass/lamp/rope production or separation service. Measured trial feedstock, rejects/rework/recovery/stocks outside Dnet; retained actual hardware/fills only with accepted shipment proof. Independent utility furnaces, cold-glass machines or general handling equipment not automatically machine mass, even in a marketed bundle.
bom_extensionrouteConditional atomic cards are not a universal BOM. Each actual missing alloy/polymer grade, abrasive/blast medium, release agent, coolant/refrigerant, gas, drive/control/heating part, retained accessory/fill, trial formulation, waste or emitted species requires its own bounded directed identity query and independent measurement. Unknown differs from zero/not_applicable; absence needs evidence.
upstreamlinksMatch actual supplied completion, grade/formulation, geography/voltage/period and external treatment route. Actual special-purpose principal function and complete machine versus intermediate module or independent ancillary require individual review. Missing upstream forbids full footprint claim.
Allocation rules · 2
Rule IDApplies toRuleSource IDs
causalsiteSeparate configurations and subdivisions first; allocate common residual by measured causal load, operating time or appropriate physical driver, retain numerator and denominator records and uncertainty. Do not average unrelated machining functions or different supplied configurations or use machine mass automatically for every utility.
rejectsacceptedInclude actual rejects, rework and qualification burdens in attributable Q for accepted output; only accepted net mass/count enters denominator. Segregate recycling transfer and treatment; do not assume avoided-product credits or zero upstream recycled burden.
Validation rules · 9
Rule IDApplies toRuleSource IDs
identitydatasetVerify complete special-purpose machinery n.e.c., full explicit isotope/glass-envelope-lamp/glass/rope-cable or reviewed residual family, principal function and delivered configuration. Reference finished44930 excludes intermediate structures/components, customer products/services, partial machines and automatically included independent ancillary equipment. Each exchange needs own species/grade/completion/state/native quantity/provider; zero/absent/unknown distinct.un-cpc-44930, census-special
denominatorall inventory rowsAll inventory uses the same accepted cohort and common period. Verify calibrated accepted net mass and N; reject and packaging mass excluded. Check q_item=Q/N then normalization by same mean M; mixed configurations are invalid.
double_countmake_buyReconcile complete bought modules versus own materials and operations, retained fills/accessories versus factory consumption, paired internal transfers and external inputs. Count each actual burden once.
water_closephysical water recordsFor each term use its own measured water fraction, density and wet/dry basis: fresh and input moisture plus reaction water and beginning stocks minus final stocks, retained product, discharge and evaporation; internal returns cancel paired. Investigate measured closure against combined sampling/meter/allocation uncertainty; no universal tolerance.
species_closematerial and chemical recordsClose each contained metal/chemical separately using each input, product, scrap, sludge, liquid and release own matched assay and dry/wet basis, reaction stoichiometry and stocks. Gross mass is not contained element. No all-inventory mass rule applies to energy or transport.
solvent_closesolvent recordsDistinguish retained solvent, recovered return, captured liquid/media, demonstrated destruction, wastewater/non-air residual and actual species air release. Capture is not destruction; an unexplained residual must be investigated, not assigned to air.
utility_closeenergy recordsReconcile purchased imports, actual on-site generation, exports and storage changes with assigned fabrication/finish/integration/test/dispatch loads in the same period and units. Shared row ONLY unassigned residual; investigate negative residual against period, unit and combined measurement uncertainty without clipping.
steam_closesteam and condensateUse supply kg times supply own MJ/kg and return kg times return own MJ/kg at measured pressure/temperature relative to common zero. If gross supply, subtract return once; if already-net invoice, do not subtract again. Keep physical steam/condensate mass balance independent from energy.
species_emissionsair releasesValidate every emitted species and compartment independently. Fuel carbon balance cannot alone establish CO or NOx. NO2 mass is not NOx reported as NO2 equivalent; keep reporting conventions and actual species identities distinct.
Processes and inputs/outputs · 5
Process IDProcess nameInput flowsOutput flows
fabricationActual structural and component fabrication115
assemblyConfigured mechanical, thermal and control integration160
qualificationObserved factory qualification119
dispatchAccepted configured machine release and packing31
servicesUnassigned common manufacturing services30

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page