Domestic non-electric iron or steel cooking appliances and plate warmers · Calculation Rules
- Lifecycle status
- Candidate
- Content maturity
- Authored methodology
- Current version
- No published versionLast updated
- Readiness
- Review required
Methodology and translation states come from the source record; publishing this website does not change their review status.
Content languages
en-US · canonicalzh-CN · Aligned
Status, classification and source details
Readiness
- Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.
Classification mapping
CPC 3.0:44821 · exact
Source
Calculation Rules
| rule_id | Applies to | Formula or rule | Inputs | Output | source_ids |
|---|---|---|---|---|---|
| period_normalization | all inventory rows | Use each attributable period exchange Q / D; preserve original numerator units; reference_product = 1 kg. | Q; D; cp_mass | q_ref | rangemaster-manufacture |
Data Quality Requirements
| requirement_id | Applies to | Requirement | Evidence |
|---|---|---|---|
| identity | all applicable rows | Confirm actual UUID/property/unit, grade/formulation, fuel, supply state/geography and downstream waste treatment interface; unresolved is explicit, not a generic substitute. | Actual supplier/site records and direct identity reads |
| coverage | all exchanges | Same configuration/BOM/period and tests; actual route absence documented. Missing actual quantities, ranges or recipes remain unknown, not zero; no factory default inferred from brochure use specifications. | Measured raw records, route matrix and uncertainty |
9. Validation Rules
| rule_id | Applies to | Rule | source_ids |
|---|---|---|---|
| reference_check | reference_product | Require positive D and N, calibrated accepted net same-configuration mass, and same-period Q including rejects/rework; 1 kg output and Q/D must reconcile. Cooking/heating hybrids require principal-function/classification authority evidence. | esse-cookers; aga-rayburn |
| water_closure | physical water and moisture records | Each wet stream uses its own measured moisture and wet/dry basis, including product, sludge, wastewater and residuals. External water plus input moisture plus beginning stock and reaction-generated water equal retained product moisture plus end stock, evaporation, discharge and reaction consumption. Pair internal returns; do not count circulation repeatedly. Investigate residual using actual combined meter/sampling/allocation uncertainty, not universal tolerance. | rangemaster-manufacture; jrc-foundry-2024 |
| metal_species_closure | physical material and species records | For each actual element/species, every input, product, scrap, slag, sludge, wastewater and release uses its OWN matched assay and wet/dry basis. Include beginning/end stocks, reaction transformations, retention and paired internal return cancellation. Gross material mass is not contained iron/chromium/nickel; investigate closure with actual combined measurement, sampling and allocation uncertainty. | jrc-foundry-2024 |
| solvent_closure | physical solvent records | For each actual solvent, reconcile fresh input and beginning stock against end stock, retained product, recovered solvent, solvent in capture media, verified destruction, air releases and non-air residues. Unknown solvent residual is not automatically an air emission. Recovery/capture is not destruction; paired returned solvent cancels once. Investigate residual against actual combined uncertainty; no assumed solvent for absent route. | rangemaster-manufacture |
| utility_closure | utility records | Process and shared-service rows reconcile SAME measured site period and units; shared service is only the unassigned residual. Do not add whole-factory meter totals to assigned submeters. Reconcile imports, actual onsite generation, exports, storage changes and steam/condensate returns; investigate negative residual using matched meter, sampling, period, stock and allocation uncertainty, never clip. Bought power is not source-specific incineration output; generation fuel is not purchased power. | rangemaster-manufacture |
| emission_evidence | elementary emissions and fuel records | Factory combustion/firing releases remain production; customer use remains separate. Fuel carbon closes total carbon but cannot prove CO, NO or NO2 amounts. Require species-specific measured/factor evidence, actual compartments and fossil/biogenic split. NOx as NO2 equivalent is a convention, not pure NO2; measured size-resolved PM10/PM2.5 are distinct, do not infer from unsized dust. Capture media and treatment residues need their own assays. | jrc-foundry-2024; esse-cookers |
10. Published Dataset Profile
| Field | Value |
|---|---|
| dataset_role | foreground_dataset |
| downstream_use | secondary_dataset; background_dataset |
| allowed_use | Manufacturing supply of declared configuration; downstream process/lifecyclemodel projection with independently defined cooking service |
| excluded_use | Universal cooker fuel/lifetime or equivalence defaults; unresolved hybrid classification; use-phase claims from factory mass |
| required_metadata | Qualifiers, D/N/M and raw Q, period, make/buy, actual routes, provider links, acceptance and downstream service boundary |
| required_quality_disclosure | Unresolved UUIDs, recipes, quantities, standalone plate-warmer evidence and classification hybrids; measurement/allocation uncertainty and completeness |
| update_trigger | Model/BOM/fuel/finish/supplier/test/route change or resolved evidence/identity gap |
11. Data Sources
| Source id | Type | Reference | Used for |
|---|---|---|---|
| un-cpc-3-0 | official_guidance | UNSD CPC Version 3.0 Explanatory Notes, 30 June 2025, p.240, 4482/44821/44822 https://unstats.un.org/unsd/classifications/Econ/Download/In%20Text/CPC_Ver_3.0_Exp_Notes_30Jun2025.pdf | Category and adjacent classification boundaries only |
| esse-cookers | handbook | ESSE Range Cookers, COOK1023 ©2023, pp.9,23–27 https://www.esse.com/wp-content/themes/esse/media-library/brochures/esse-cooker-brochure.pdf | Actual wood cooking architecture, handmade assembly and cooking/heating counterexample; electric pages excluded; no factory quantities |
| rangemaster-gas | handbook | Rangemaster Built-In Appliances, undated inspected original, p.9 https://www.rangemaster.co.uk/sites/default/files/2019-05/RM_Built-In_Brochure_Sept2018_V1.pdf | Stainless gas hobs, cast-iron supports, LPG kit; neighboring electric models are counterevidence |
| rangemaster-manufacture | handbook | Rangemaster Quick Guide, undated inspected original, pp.2–3 https://www.rangemaster.co.uk/sites/default/files/2021-02/Rangemaster%20Quick%20Guide.pdf | Actual cooker steel press/cut/wash/polish/enamel, folded frame and testing; conditional routes only, no universal formulation or quantity |
| aga-sustainability | handbook | AGA Sustainability, publisher HTML https://old.agaliving.com/buying/sustainability | Actual cast-iron cooker melting and packaging; environmental marketing and percentages are not adopted factors |
| aga-rayburn | handbook | AGA Rayburn, publisher HTML https://www.agaliving.com/products/aga-rayburn/ | Oil/gas cast-iron cooking and warming ovens, vitreous enamel; combined heating needs actual principal-function review |
| jrc-foundry-2024 | official_guidance | JRC Smitheries and Foundries BREF, EUR 40127, 2024, section 2.2.1.1, pp.67–68, DOI 10.2760/4805267 https://bureau-industrial-transformation.jrc.ec.europa.eu/sites/default/files/2024-12/SF_BREF_2024-bref.pdf | Conditional actual foundry process decomposition only; not a domestic-cooker recipe, emission factor or universal process requirement |
Raw downloads
These files are byte-identical to the canonical files for this revision in the repository.
Complete field inspector