1. Scope and Applicability

This rule produces a factory-gate foreground data package for one accepted, complete, non-electric domestic cooking appliance or plate warmer whose principal body is iron or steel. Gas-fired domestic hobs and cookers are representative routes; the declared configuration may instead be another non-electric cooking or warming design. Record its fuel, burner or heater design, material bill, surface finish and sale state. Manufacture of loose replacement parts, electric appliances, copper-bodied appliances, use-stage cooking fuel and end-of-life treatment are outside this factory-gate package. The category distinction follows un-cpc-3-2025; product-specific bill-of-material collection follows eu-jrc-cooking-appliances-2020.

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.metal-products-machinery-and-equipment.special-purpose-machinery.cooking-appliances-and-plate-warmers-non-electric-domestic-of-iron-or-steel
classification_refsCPC 3.0 44821, classification context only; no accepted mapping is asserted
covered_productsComplete non-electric domestic iron or steel cooking appliances and plate warmers, including gas-fired domestic hobs and cookers
excluded_productsElectric cooking appliances; non-cooking space heaters of CPC 44822; separately sold parts of CPC 44832; copper-bodied cooking or heating appliances of CPC 42912; commercial cooking equipment
representative_productAccepted, complete iron or steel domestic gas hob with installed burner and controls
production_routeSteel housing fabrication, route-specific surface finishing, purchased functional component assembly, acceptance testing and factory-gate packaging
market_stateFinished and accepted appliance at factory gate, with declared sales packaging; transport packaging is excluded from net product mass

3. Reference Flow

FieldValue
WhatA complete domestic appliance that cooks food or warms plates without electric heat
How muchOne accepted finished appliance of the declared model and configuration
How wellMeets the manufacturer's declared cooking or warming performance and applicable acceptance test; fuel and installed components are identified
How long or cycleAt factory acceptance; no assumed service life or cooking cycle is embedded in this production reference
reference_flow_linkfinished_appliance
FieldValue
Reference amountM
Reference product flowCooking appliances and plate warmers, non-electric, domestic, of iron or steel 6cc6000a-58ba-4ba3-bfa1-94ee239070ff
Reference flow propertyMass 93a60a56-a3c8-11da-a746-0800200b9a66
Reference unit groupUnits of mass 93a60a57-a4c8-11da-a746-0800200c9a66
Reference unitkg
Required qualifiersmodel; configuration; fuel or heat source; iron or steel body grade; installed burner or warming assembly; coating route; sales packaging state; manufacturing site and period

The foreground producer measures M for the same accepted configuration. Inventory is collected per one accepted finished unit and delivered with M kg as the reference product; no universal appliance mass is assumed.

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
reference_massreference productMass 93a60a56-a3c8-11da-a746-0800200b9a66kgM = accepted net mass of one complete unit of the same configuration in kg; collect using cp_mass.
electricity_energyfabrication_electricityNet calorific valueMJRecord alternating-current electricity consumed by the declared fabrication and assembly processes in MJ; convert a metered kWh record using 1 kWh = 3.6 MJ, and retain the original reading.

5. System Boundary

Boundary Abstraction

FieldValue
declared_starting_conditionIron or steel sheet and purchased burner components enter the foreground factory; their upstream production is linked as separate background datasets
starting_condition_rolePurchased product inputs at the gate of the first included factory process
product_classification_scopeFinished CPC 44821 appliance; separately supplied CPC 44832 parts remain input components
recursive_input_ruleIf a complete same-category appliance is purchased as an input, disclose and link its upstream dataset rather than recursively modelling it as fresh factory output
upstream_dataset_requirementLink upstream datasets for purchased metal, functional components, coating material, gas, electricity and packaging, with geography and technology recorded
disclosureDeclare site, period, model, configuration, fuel, process route, purchased-versus-in-house components, mass M and all exclusions
rule_idapplies_torulesource_ids
boundary_gatefactory-gate foreground packageInclude fabrication, route-specific finishing, final assembly, acceptance testing, attributable factory energy, scrap and packaging up to release of the accepted appliance.eu-jrc-cooking-appliances-2020; us-epa-metal-fabrication-2007
boundary_exclusionsdownstream stagesExclude customer cooking fuel, distribution, installation and end-of-life from this factory-gate inventory; disclose any separately modelled downstream scenarios.eu-jrc-cooking-appliances-2020

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
housing_fabricationSteel housing fabricationconditionalInclude when sheet-metal housing cutting and forming occur at the declared factoryForeground cutting, forming and joiningper one accepted finished unit
surface_coatingPowder coatingconditionalInclude when powder coating is applied to the housing at the declared factoryForeground finishingper one accepted finished unit
final_assembly_testFinal assembly and acceptance testrequiredEvery accepted complete appliance is assembled and testedForeground assembly and testper one accepted finished unit
sales_packagingCorrugated-box packagingconditionalInclude when a corrugated board box is supplied with the factory-gate sale unitForeground packagingper one accepted finished unit

Process: Steel housing fabrication (housing_fabrication)

Inputs

Product flows
Cold-rolled steel sheet for housing (steel_sheet_input)

For the sheet-fabrication route, record the mass of non-alloy cold-rolled steel sheet entering the housing line, including sheet that becomes measured offcut. Supplier grade and coating state must be declared; its Tiangong flow identity remains unresolved.

  • Selected flow: Cold-rolled non-alloy steel sheet
  • Flow property / unit: Mass / kg
  • Amount rule: Measured sheet issued per one accepted finished unit; record supplier mass and reconcile stock changes.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_materials
  • Sources: eu-jrc-cooking-appliances-2020; us-epa-metal-fabrication-2007
Alternating-current fabrication electricity (fabrication_electricity)

Meter or allocate the electricity used by cutting, forming, joining and installed finishing and assembly equipment; avoid double counting shared meters.

  • Selected flow: Alternating current 949661a5-2af6-4e66-adf8-74f5fca306a9
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Measured attributable alternating-current electricity in MJ per one accepted finished unit; convert recorded kWh using electricity_energy.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_electricity
  • Sources: us-epa-metal-fabrication-2007
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Steel sheet offcut scrap (steel_scrap_output)

Weigh clean steel offcuts leaving the fabrication line. Record contaminated swarf separately in the produced dataset if present; the selected flow here is only steel scrap.

  • Selected flow: Steel scrap 37997e0e-e34b-4ab9-a642-5d86f4333919
  • Flow property / unit: Mass / kg
  • Amount rule: Measured steel scrap dispatched or stock-adjusted per one accepted finished unit.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_scrap
  • Sources: us-epa-metal-fabrication-2007
Elementary flows

Process: Powder coating (surface_coating)

Inputs

Product flows
Powder paint applied to housing (powder_coating_input)

Include only when the declared factory uses powder paint; record purchased and consumed coating powder, with losses assigned to this line.

  • Selected flow: Powder Coating 6e3010f9-fbd3-48f6-95fc-c1b38d2800d2
  • Flow property / unit: Mass / kg
  • Amount rule: Measured powder paint consumed per one accepted finished unit when powder coating is used.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_coating
  • Sources: us-epa-metal-fabrication-2007
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Elementary flows

Process: Final assembly and acceptance test (final_assembly_test)

Inputs

Product flows
Purchased domestic gas burner assembly (domestic_gas_burner_input)

Include for a gas-fired configuration with a purchased domestic hob burner assembly; record its supplier identity and delivered mass. The searched industrial burner records are not this product.

  • Selected flow: Domestic gas hob burner assembly
  • Flow property / unit: Mass / kg
  • Amount rule: Measured mass of purchased domestic burner assemblies per one accepted gas-fired finished unit.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_components
  • Sources: eu-jrc-cooking-appliances-2020
Natural gas for gas-fired acceptance test (acceptance_test_natural_gas)

Include only when natural gas is actually burned during the factory acceptance test; use a separate atomic fuel row in the produced dataset for any other test fuel.

  • Selected flow: natural gas in the gaseous state 4f19ca0e-7b3b-11dd-ad8b-0800200c9a66
  • Flow property / unit: Volume / m3
  • Amount rule: Metered natural gas consumed in acceptance testing per one accepted finished unit when this fuel is used.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_test_gas
  • Sources: eu-jrc-cooking-appliances-2020
Waste flows
Elementary flows

Outputs

Product flows
Accepted finished cooking appliance or plate warmer (finished_appliance)

The reference product is one accepted complete unit. Its net mass M excludes the transport package and is weighed for the same configuration.

  • Selected flow: Cooking appliances and plate warmers, non-electric, domestic, of iron or steel 6cc6000a-58ba-4ba3-bfa1-94ee239070ff
  • Flow property / unit: Mass / kg
  • Amount rule: M kg
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_mass
  • Sources: un-cpc-3-2025; eu-jrc-cooking-appliances-2020
Waste flows
Elementary flows

Process: Corrugated-box packaging (sales_packaging)

Inputs

Product flows
Corrugated board sale box (corrugated_box_input)

Include only when a corrugated board sale box accompanies the accepted appliance at the declared factory gate. This box is outside the measured net product mass M.

  • Selected flow: corrugated board boxes 4f197bec-7b3b-11dd-ad8b-0800200c9a66
  • Flow property / unit: Mass / kg
  • Amount rule: Measured mass of corrugated sale boxes issued per one accepted finished unit when boxed.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per one accepted finished unit
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_packaging
  • Sources: eu-jrc-cooking-appliances-2020
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Elementary flows

7. Allocation and Co-product Handling

rule_idapplies_torulesource_ids
allocation_subdivideshared factory processesFirst separate metered process lines, production periods and product configurations; retain directly traceable sheet, scrap, coating, burner, test gas and box records.us-epa-metal-fabrication-2007; eu-jrc-cooking-appliances-2020
allocation_sharedremaining shared energy and wasteIf direct measurement cannot separate a shared process, allocate by a documented physical driver tied to that process, such as measured machine time; disclose the driver, denominator and sensitivity.us-epa-metal-fabrication-2007
scrap_no_creditsteel scrap outputRecord steel scrap as an output; do not subtract an assumed recycling credit inside the factory-gate foreground inventory.us-epa-metal-fabrication-2007

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_massfinal_assembly_testaccepted reference productcalibrated scale recordmodel; configuration; serial number; accepted net mass MWeigh the accepted complete unit on a calibrated scale, excluding transport packaging; reconcile the same configuration and acceptance record.kgeach accepted model or production lotdeclared production perioddeclared factoryaccepted net mass per unitcalibration certificate; acceptance record
cp_materialshousing_fabricationsteel sheet inputsupplier and issue ledgersteel grade; sheet form; received mass; issued mass; opening and closing stock; accepted unitsReconcile supplier and issue records with stock change for the declared configuration.kgeach lotdeclared production periodhousing lineissued sheet mass / accepted unitssupplier invoice; stock ledger
cp_electricityhousing_fabricationalternating-current inputmeter recordmeter id; kWh reading; period; line allocation driver; accepted unitsRead the calibrated meter and convert kWh to MJ; document allocation of shared electricity.MJmonthly or batchdeclared production periodincluded factory linesattributable MJ / accepted unitsmeter readings; allocation worksheet
cp_scraphousing_fabricationsteel offcut outputweighbridge and stock recordscrap type; dispatched mass; opening and closing stock; accepted unitsWeigh clean steel offcuts and reconcile stock change.kgeach dispatch or batchdeclared production periodhousing linesteel scrap mass / accepted unitsweighbridge ticket; stock ledger
cp_coatingsurface_coatingpowder paint inputcoating issue recordpowder type; issued mass; returned mass; accepted unitsReconcile powder issues and returns when this route is used.kgeach batchdeclared production periodcoating lineconsumed powder mass / accepted unitsissue ledger; route record
cp_componentsfinal_assembly_testburner assembly inputsupplier BoM and receiptburner model; supplier; receipt mass; installed count; accepted unitsReconcile received domestic burner assemblies with installed components and rejected units.kgeach model or lotdeclared production periodassembly lineinstalled burner mass / accepted unitssupplier BoM; receipt; assembly traveler
cp_test_gasfinal_assembly_testnatural gas test inputgas meter and test recordgas meter id; m3 reading; gas type; test duration; accepted unitsMeter natural gas attributable to acceptance tests for the declared gas configuration.m3each test batchdeclared production periodtest lineattributable natural gas m3 / accepted unitsgas meter record; test log
cp_packagingsales_packagingcorrugated sale box inputpackaging issue recordbox specification; issued mass; accepted unitsReconcile corrugated boxes issued to accepted units when boxed.kgeach lotdeclared production periodpacking lineissued box mass / accepted unitspackaging ledger; supplier specification

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids

Data Quality Requirements

requirement_idApplies toRequirementEvidence
dq_configurationall included rowsKeep model, fuel, coating route and accepted configuration consistent with M and the bill of materials.eu-jrc-cooking-appliances-2020; acceptance and supplier records
dq_periodall collected rowsUse one declared production period; reconcile shared meter and stock boundaries to accepted output.meter, ledger and acceptance dates
dq_identityunresolved UUID rowsPreserve the concrete physical name and leave UUID blank until an exact public TianGong flow is verified.flow identity review

9. Validation Rules

rule_idapplies_torulesource_ids
validate_massreference and material balanceConfirm M is measured for the accepted configuration and the finished output equals M kg; reconcile sheet issued, component mass, scrap and stock movements without forcing equality across unlike materials.eu-jrc-cooking-appliances-2020; us-epa-metal-fabrication-2007
validate_routesconditional process rowsConfirm powder paint, domestic burner, natural gas and corrugated box are included only when their declared routes apply; require an explicit absence reason otherwise.eu-jrc-cooking-appliances-2020
validate_sourcesforeground data packageRequire meter, supplier, weighbridge, BoM and acceptance records for nonzero rows; disclose geography, technology, time and unresolved UUIDs.eu-jrc-cooking-appliances-2020; us-epa-metal-fabrication-2007

10. Published Dataset Profile

FieldValue
dataset_roleFactory-gate foreground data package for an accepted complete appliance
downstream_useMay become a reviewed secondary_dataset or background_dataset and support process or lifecyclemodel projections
allowed_useUse for the declared model, site, period, fuel and finish route, with upstream links and disclosed UUID gaps
excluded_useDo not treat this production package as a use-stage cooking or end-of-life result; do not transfer it to electric, copper-bodied or industrial equipment
required_metadatamodel; configuration; fuel; iron or steel grade; site; period; M and measurement evidence; BoM; process routes; packaging state; upstream dataset geography
required_quality_disclosuredirect measurements; allocation drivers; excluded stages; unmatched flow UUIDs; unresolved range evidence; data coverage
update_triggerReissue when material design, burner, fuel, coating route, supplier, site or measurement protocol changes materially

11. Data Sources

Source idTypeReferenceUsed for
un-cpc-3-2025official_guidanceCPC Version 3.0 Structure, United Nations Statistics Division, 30 June 2025, https://unstats.un.org/unsd/classifications/Econ/Download/In%20Text/CPC_Ver_3.0_Structure_30Jun2025.csvProduct class and adjacent exclusions only
eu-jrc-cooking-appliances-2020official_guidanceReview study of Ecodesign and Energy Labelling for Cooking appliances, first draft, February 2020, https://susproc.jrc.ec.europa.eu/product-bureau/sites/default/files/2020-07/CA_%20Prep%20Study_draft1_Feb2020.pdfDomestic gas appliance scope; product-specific BoM and component collection; no empirical PCR range
us-epa-metal-fabrication-2007official_guidanceClean Lines: Strategies for Reducing Your Environmental Footprint, U.S. Environmental Protection Agency, November 2007, https://www.epa.gov/sites/default/files/2015-03/documents/fabrication.pdfFabrication process map, steel scrap and machining-fluid separation

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 2
Rule IDApplies toRuleSource IDs
boundary_gatefactory-gate foreground packageInclude fabrication, route-specific finishing, final assembly, acceptance testing, attributable factory energy, scrap and packaging up to release of the accepted appliance.eu-jrc-cooking-appliances-2020, us-epa-metal-fabrication-2007
boundary_exclusionsdownstream stagesExclude customer cooking fuel, distribution, installation and end-of-life from this factory-gate inventory; disclose any separately modelled downstream scenarios.eu-jrc-cooking-appliances-2020
Allocation rules · 3
Rule IDApplies toRuleSource IDs
allocation_subdivideshared factory processesFirst separate metered process lines, production periods and product configurations; retain directly traceable sheet, scrap, coating, burner, test gas and box records.us-epa-metal-fabrication-2007, eu-jrc-cooking-appliances-2020
allocation_sharedremaining shared energy and wasteIf direct measurement cannot separate a shared process, allocate by a documented physical driver tied to that process, such as measured machine time; disclose the driver, denominator and sensitivity.us-epa-metal-fabrication-2007
scrap_no_creditsteel scrap outputRecord steel scrap as an output; do not subtract an assumed recycling credit inside the factory-gate foreground inventory.us-epa-metal-fabrication-2007
Validation rules · 3
Rule IDApplies toRuleSource IDs
validate_massreference and material balanceConfirm M is measured for the accepted configuration and the finished output equals M kg; reconcile sheet issued, component mass, scrap and stock movements without forcing equality across unlike materials.eu-jrc-cooking-appliances-2020, us-epa-metal-fabrication-2007
validate_routesconditional process rowsConfirm powder paint, domestic burner, natural gas and corrugated box are included only when their declared routes apply; require an explicit absence reason otherwise.eu-jrc-cooking-appliances-2020
validate_sourcesforeground data packageRequire meter, supplier, weighbridge, BoM and acceptance records for nonzero rows; disclose geography, technology, time and unresolved UUIDs.eu-jrc-cooking-appliances-2020, us-epa-metal-fabrication-2007
Processes and inputs/outputs · 4
Process IDProcess nameInput flowsOutput flows
housing_fabricationSteel housing fabrication21
surface_coatingPowder coating10
final_assembly_testFinal assembly and acceptance test21
sales_packagingCorrugated-box packaging10

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page