1. Scope and Applicability

This PCR governs production of a separately delivered genuine dedicated part for a line telephone with cordless handset, cellular/other wireless telephone, or other telephone/network communication apparatus. Determine the delivered article from its drawing, fit/interface, BOM, completion state and remaining assembly; marketing as a spare and host dependence do not establish part identity. Functionality alone does not decide the boundary. [cpc3-telecom; apple-enclosure]

Complete telephone sets, completed replacement cordless handsets, routers, modems and completed communication apparatus remain outside, even if they need registration, a cable, power, software or a host chassis to operate. Panasonic optional handset listings are counterevidence against treating compatibility as proof of incomplete parts. ADP network cards are separately classified; generic ICs, bare PCBs, standalone connectors, microphones, batteries, resin and metal stock are upstream inputs, not output parts under this PCR. [cpc3-telecom; panasonic-handset; census-electronics]

Enclosures, handset constituent shells, shields, mounting pieces, dedicated connector flexes and passive antenna assemblies may qualify when the actual host and dedicated delivered state are demonstrated. Electronic/RF/network modules are not excluded because they contain electronics or lack UUIDs: include only a genuine dedicated incomplete constituent, with actual remaining host assembly documented and a classification review ruling out completed apparatus or a separately classified generic component. Cisco active uplink modules support real modular interfaces but do not themselves prove parts classification; its blank module illustrates host-specific mechanical fit and airflow requirements. [apple-enclosure; apple-connector; taoglas-cellular; cisco-network-module]

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.metal-products-machinery-and-equipment.radio-television-and-communication-equipment-and-apparatus.parts-for-the-goods-of-subclasses-47221-to-47223
classification_refsCPC 3.0 47401
covered_productsDrawing-defined dedicated incomplete parts for qualifying telephone or network hosts; bounded conditional mechanical, polymer, connector, passive antenna and electronic/RF subassembly routes
excluded_productsCompleted telephone/communication apparatus; ADP network cards; generic separately classified electronic components and material stock
representative_productOne drawing/revision-defined telephone enclosure delivered without the host logic board, battery and display; no assumed grade or weight
production_routeActual make/buy route: purchase completed part inputs or fabricate specified mechanical/polymer/electronic constituents; then actual finish, part assembly and acceptance
market_stateAccepted separately delivered dedicated part at factory gate; host assembly remains outside

3. Reference Flow

FieldValue
WhatProvide the specified constituent fit, containment, mounting or electrical/RF interface in the identified host
How much1 kg of accepted net part of one drawing/revision and delivered state
How wellMeet actual drawing tolerances, grade/BOM and specified part acceptance tests; no invented generic RF performance
How long or cycleOne production and factory acceptance cycle; no assumed host operating life
reference_flow_linkfinal_part
FieldValue
Reference amount1
Reference product flowParts for the goods of subclasses 47221 to 47223 bf7766aa-8f63-4869-bd70-2090483f4437
Reference flow propertyMass 93a60a56-a3c8-11da-a746-0800200b9a66
Reference unit groupUnits of mass 93a60a57-a4c8-11da-a746-0800200c9a66
Reference unitkg
Required qualifiershost model/function; drawing/part number/revision; delivered completion state; remaining host assembly; classification review; grade/formulation/BOM; make/buy and included operations; test specification; accepted net batch mass; calibration/tare; site/period; supplier and utility interface; waste fate

All qualifiers must be declared in foreground package metadata or equivalent product/process notes. A mass unit compares the same part specification and state, not functional equivalence of different telecom components.

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
reference_massreference productMasskgCollect accepted net part batch mass using cp_mass on calibrated scales, same drawing/revision/BOM/state; exclude transport packaging and non-delivered tooling. Inventory and collection use per 1 kg reference flow.
count_masscounted physical part and material recordsMasskgCount records require calibrated measured accepted batch net mass for the identical counted population; do not infer mass from nominal handset weight, housing percentage or an unrelated revision. Divide batch exchanges by that measured accepted kg; individual weighing/count conversion must reproduce the same net batch basis.
species_basismaterial, chemical, residual and emitted-species mass balancesMasskgKeep gross material and contained-element masses separate; assays must match grade, solution concentration, wet/dry state and sampling period.
energy_unitstest_power; factory_power; natural_gasNet calorific valueMJEnergy stays MJ; calibrated kWh converts by 3.6 MJ/kWh. Gas volume requires supplier calorific value and measured conditions.

5. System Boundary

Boundary Abstraction

FieldValue
declared_starting_conditionReceived certified stock or purchased completed constituent at declared supplier gate and delivery state
starting_condition_rolePurchased upstream intermediate/component interface
product_classification_scopeDedicated parts for CPC3 hosts47221–47223; classification of the actual delivered part reviewed independently
recursive_input_ruleTreat purchased same-category part as an upstream cut interface with completed operations recorded; do not recursively add its manufacturing again
upstream_dataset_requirementMatch physical state/grade, geography/time and supplier gate; include supplier production once, flag absent provider coverage; a product UUID is not an upstream burden dataset
disclosureDelivery state, included/excluded operations, actual route gates, supplier coverage and residual identity/quantity gaps
rule_idApplies toRulesource_ids
boundary_deliveryall processesRequire documented incomplete constituent identity. Host fit alone and absence of stand-alone operation are insufficient; completed apparatus and separately classified components stay outside final output.cpc3-telecom; panasonic-handset; census-electronics
boundary_make_buyall processesFor every BOM line record make/buy, incoming completion, upstream provider coverage and operations performed here. If bought board/antenna/enclosure already embeds copper, polymer and IC manufacture, do not add embedded inputs or operations again. If made here include actual materials, chemistry, waste and energy.apple-enclosure; taoglas-cellular
boundary_factoryall processesInclude attributable fabrication, finish, assembly, rework, acceptance testing, utilities, treatment and packing. Factory RF/continuity tests are production; later telephone calls, data traffic, host installation, repair and end-of-life are outside this production package and require separate declared lifecycle stages.apple-enclosure; cisco-network-module

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
p_receiptReceipt and upstream interfacerequiredEvery selected partforegroundfinal_part
p_mechanicalMechanical forming and machiningconditionalDrawing-specific metal enclosure, shield or mounting member made on siteforegroundfinal_part
p_polymerPolymer molding and trimmingconditionalDrawing-specific polymer enclosure, insert or handset shell made on siteforegroundfinal_part
p_electronicDedicated electronic or RF subassembly fabricationconditionalGenuine incomplete dedicated part requiring host integration; actual board/antenna/connector operations performed on siteforegroundfinal_part
p_finishSurface finishing and cleaningconditionalActually applied drawing-specified coating, bonding or cleaningforegroundfinal_part
p_assemblyPart assembly and acceptancerequiredActual assembly, dimensional/continuity/RF acceptance as appropriate to delivered partforegroundfinal_part
p_utilitiesUtilities and pollution controlrequiredAttributable actual utilities and treatment; combustion only when presentforegroundfinal_part
p_dispatchPacking and dispatchrequiredAccepted net part at supplier gatereferencefinal_part

Rows below are atomic route candidates, not a universal BOM or recipe. Apply only the actual certified grade/formulation and delivered interface stated on each card; add a separate named row for every actual different material, component, chemical, fuel, waste or species. Missing UUID does not exclude a genuine route. Record not_applicable only with route evidence; zero, unknown and not_applicable are distinct. Internal process transfers are paired and cancel at the aggregate gate, while their repeated processing remains.

Process: Receipt and upstream interface (p_receipt)

Inputs

Product flows
Drawing-specific molded telephone handset shell (bought_shell)

Only when bought complete as this shell; supplier production included once, no average housing-share proxy.

  • Selected flow: Drawing-specific molded telephone handset shell
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_bom
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_bom
  • Sources: apple-enclosure; protolabs-molding
Host-dedicated populated telephone circuit board subassembly (bought_board)

Only when actual dedicated subassembly is purchased; finished-apparatus and generic bare-board classification review still required.

  • Selected flow: Host-dedicated populated telephone circuit board subassembly
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_bom
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_bom
  • Sources: cpc3-telecom
Host-dedicated flexible cellular antenna assembly (bought_antenna)

Only when host drawing, feed/connector and installed state establish dedicated part status; bought antenna production covered once.

  • Selected flow: Host-dedicated flexible cellular antenna assembly
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_bom
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_bom
  • Sources: taoglas-cellular
Drawing-specific telephone USB-C flex connector assembly (bought_connector)

Only for a dedicated connector assembly fitted to host drawing; generic standalone connector belongs to its own category.

  • Selected flow: Drawing-specific telephone USB-C flex connector assembly
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_bom
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_bom
  • Sources: apple-connector

Process: Mechanical forming and machining (p_mechanical)

Inputs

Product flows
EN AW-6061 aluminum billet (aluminum_stock)

Conditional candidate grade only when actual certificate and drawing match; separately add each other certified grade used.

  • Selected flow: EN AW-6061 aluminum billet
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_material
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_material
  • Sources: apple-enclosure
C11000 copper strip (copper_stock)

Only when actual shield or conductor is formed from certified C11000 strip; do not infer alloy from host identity.

  • Selected flow: C11000 copper strip
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_material
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_material
  • Sources: cpc3-telecom
Mineral-oil cutting fluid concentrate (cutting_oil)

Only when this formulation is used; record concentration, active species, dilution water and supplier formulation.

  • Selected flow: Mineral-oil cutting fluid concentrate
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_chem
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_chem
  • Sources: apple-enclosure

Outputs

Waste flows
EN AW-6061 machining scrap (aluminum_scrap)

External scrap only; opening/closing scrap and internal remelt transfers remain distinct.

  • Selected flow: EN AW-6061 machining scrap
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_residual
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_residual
  • Sources: apple-enclosure
C11000 copper stamping scrap (copper_scrap)

When copper route is present; grade and actual treatment provider required.

  • Selected flow: C11000 copper stamping scrap
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_residual
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_residual
  • Sources: cpc3-telecom

Process: Polymer molding and trimming (p_polymer)

Inputs

Product flows
ABS molding resin granulate (abs_resin)

Only when exact supplier ABS grade is specified; actual additives, recycled content and drying records required.

  • Selected flow: ABS molding resin granulate
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_material
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_material
  • Sources: protolabs-molding
PC/ABS molding resin granulate (pcabs_resin)

Alternative actual resin route, not additional mandatory resin; retain declared blend/grade and drying/regrind records.

  • Selected flow: PC/ABS molding resin granulate
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_material
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_material
  • Sources: protolabs-molding

Outputs

Waste flows
ABS molding reject (abs_reject)

When ABS route occurs; do not count internally returned sprues again as external input or waste.

  • Selected flow: ABS molding reject
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_residual
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_residual
  • Sources: protolabs-molding

Process: Dedicated electronic or RF subassembly fabrication (p_electronic)

Inputs

Product flows
Polyimide flexible copper-clad circuit substrate (bare_flex)

Only for actual on-site dedicated flex/antenna pattern manufacture; bought completed flex has embedded burden instead.

  • Selected flow: Polyimide flexible copper-clad circuit substrate
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_bom
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_bom
  • Sources: taoglas-cellular
Packaged radio-frequency integrated circuit (mounted_ic)

Only when this purchased package is mounted here in genuine dedicated incomplete telecom subassembly; no mandatory chip fabrication.

  • Selected flow: Packaged radio-frequency integrated circuit
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_bom
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_bom
  • Sources: cpc3-telecom
SAC305 solder paste (solder)

Actual tin-silver-copper alloy assay and flux fraction; distinguish gross paste from contained Sn,Ag,Cu.

  • Selected flow: SAC305 solder paste
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_chem
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_chem
  • Sources: apple-connector
Aqueous ferric chloride etchant (etchant)

Only if actual on-site copper etching uses this solution; concentration and bath stock required; no recipe inferred from antenna datasheet.

  • Selected flow: Aqueous ferric chloride etchant
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_chem
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_chem
  • Sources: taoglas-cellular

Outputs

Waste flows
Copper-bearing spent ferric chloride etchant (etchant_waste)

Only from this etch route; gross liquid mass and matched copper/iron assay separate, licensed treatment interface.

  • Selected flow: Copper-bearing spent ferric chloride etchant
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_residual
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_residual
  • Sources: taoglas-cellular

Process: Surface finishing and cleaning (p_finish)

Inputs

Product flows
Isopropyl alcohol cleaning solvent (ipa)

Only if actual factory cleaning uses IPA; repair-source mention is evidence of solvent identity, not a factory consumption default.

  • Selected flow: Isopropyl alcohol cleaning solvent
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_chem
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_chem
  • Sources: apple-connector
Acrylic pressure-sensitive adhesive film (adhesive)

Only if actual drawing/supplier composition confirms this film; Taoglas adhesive trade name alone cannot establish polymer composition.

  • Selected flow: Acrylic pressure-sensitive adhesive film
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_chem
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_chem
  • Sources: taoglas-cellular

Outputs

Elementary flows
Isopropyl alcohol to air (ipa_air)

Measured or species-specific calculated post-control release only; retain recovery and solvent stock changes.

  • Selected flow: Isopropyl alcohol to air
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_emission
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_emission
  • Sources: apple-connector

Process: Part assembly and acceptance (p_assembly)

Inputs

Product flows
Alternating current (test_power)

Only for CN customer-side 1–35 kV grid supply, allocated actual factory acceptance/test consumption; other country/voltage requires matching identity.

  • Selected flow: Alternating current 3d76981f-964a-4865-b588-0e067a2a1163
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_energy
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_energy
  • Sources: cpc3-telecom

Process: Utilities and pollution control (p_utilities)

Inputs

Product flows
Alternating current (factory_power)

Same verified CN1–35kV customer interface, excluding test_power already metered; no incineration-specific power substituted as grid supply.

  • Selected flow: Alternating current 3d76981f-964a-4865-b588-0e067a2a1163
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_energy
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_energy
  • Sources: protolabs-molding
Industrial process water (water)

Actual purchased supply; internal cooling circulation is not repeated purchased input.

  • Selected flow: Industrial process water
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_water
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_water
  • Sources: protolabs-molding
Pipeline natural gas (natural_gas)

Only actual on-site gas heating/drying; measured volume needs supplier calorific value and conditions; no combustion in electric-only route.

  • Selected flow: Pipeline natural gas
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_energy
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_energy
  • Sources: protolabs-molding

Outputs

Waste flows
Copper-bearing industrial wastewater (wastewater)

Only actual aqueous metal route; record separate suspended/dissolved species and receiving treatment; add separate other effluent streams.

  • Selected flow: Copper-bearing industrial wastewater
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_water
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_water
  • Sources: taoglas-cellular
Copper-bearing wastewater treatment sludge (sludge)

Only actual treatment output; wet/dry basis, copper assay and treatment fate required.

  • Selected flow: Copper-bearing wastewater treatment sludge
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_residual
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_residual
  • Sources: taoglas-cellular
Elementary flows
Fossil carbon dioxide to air (co2)

Only actual combustion, with fuel carbon and oxidation evidence and separation from upstream purchased electricity.

  • Selected flow: Fossil carbon dioxide to air
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_emission
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_emission
  • Sources: protolabs-molding
Carbon monoxide to air (co)

Only species-specific actual measured or applicable factor evidence; fuel-carbon balance alone cannot determine CO.

  • Selected flow: Carbon monoxide to air
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_emission
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_emission
  • Sources: protolabs-molding
Nitrogen dioxide to air (no2)

Only evidence identifying NO2 species; aggregate NOx as NO2 equivalent is not automatically pure NO2.

  • Selected flow: Nitrogen dioxide to air
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_emission
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_emission
  • Sources: protolabs-molding

Process: Packing and dispatch (p_dispatch)

Inputs

Product flows
Corrugated cardboard carton (box)

Actual outgoing part carton only, separately from accepted part net mass.

  • Selected flow: Corrugated cardboard carton
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_pack
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: apple-enclosure
Static-shielding metallized polyethylene bag (esd_bag)

Only actual bag for electronic/RF part; composition and supplier coverage required.

  • Selected flow: Static-shielding metallized polyethylene bag
  • Flow property / unit: Mass / kg
  • Amount rule: Measured attributable exchange divided by accepted net part batch mass in kg; cp_pack
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_pack
  • Sources: cisco-network-module

Outputs

Product flows
Accepted drawing-defined dedicated telephone or network apparatus part (final_part)

Exactly the delivered part state and drawing/revision; completed apparatus excluded.

  • Selected flow: Parts for the goods of subclasses 47221 to 47223 bf7766aa-8f63-4869-bd70-2090483f4437
  • Flow property / unit: Mass / kg
  • Amount rule: 1 kg
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_mass
  • Sources: cpc3-telecom; apple-enclosure

7. Allocation and Co-product Handling

rule_idApplies toRulesource_ids
allocation_causalityshared factory operationsInvestigate subdivision/system expansion first. If unavoidable, retain total inventories and choose demonstrated physical causality; use actual molding shot/cavity loading, machining time, reflow loading or measured testing demand as appropriate, not part mass merely because output is kg. Other relationships need justification and sensitivity.ef-allocation-2021
allocation_residualscrap and reworkDo not assume sold scrap is a co-product or avoided-primary-material credit. Disclose selected recycling/treatment allocation, provider and fate; cancel internal regrind/return transfers but retain repeated energy and losses. Rejected parts and retests contribute to the accepted output denominator.ef-allocation-2021

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_massp_dispatchaccepted net partforeground_recorddrawing; revision; host; delivered state; batch; tare; calibrated accepted net kg; accepted countWeigh the identical accepted part population on calibrated scales excluding transport packaging; retain traceable batch/count pairing and acceptance record.kgeach batch and reporting periodsame production period and drawing revisionactual site and traceable supplierper 1 kg reference flowcalibration; traceability; uncertainty; reconciliation
cp_bomp_receiptpurchased constituentforeground_recordpart number; state; make/buy; supplier; provider scope; delivery mass; stock changeReconcile receipt/issue/BOM and supplier scope with actual drawing; weigh components when counts supplied.kgeach batch and reporting periodsame production period and drawing revisionactual site and traceable supplierper 1 kg reference flowcalibration; traceability; uncertainty; reconciliation
cp_materialp_mechanicalcertified stockforeground_recordgrade; formulation; dry basis; batch; received/issued mass; accepted mass; stockUse calibrated weighbridge or scale and certificate; reconcile scrap/regrind and opening/closing stocks without a fixed yield.kgeach batch and reporting periodsame production period and drawing revisionactual site and traceable supplierper 1 kg reference flowcalibration; traceability; uncertainty; reconciliation
cp_chemp_finishspecific chemicalforeground_recordspecies; grade; concentration; active fraction; supplier; weighed consumption; bath stock; reaction; recoveryReconcile metered additions, assay and stock records; distinguish gross formulation mass from each active chemical.kgeach batch and reporting periodsame production period and drawing revisionactual site and traceable supplierper 1 kg reference flowcalibration; traceability; uncertainty; reconciliation
cp_energyp_utilitiesactual energy interfaceforeground_recordmeter; voltage; country; provider; process/load; test duration; kWh; fuel volume; calorific valueSubmeter actual process/test energy, retain load allocation and supplier interface; convert electricity kWh to MJ and fuel volume using actual conditions and calorific value.MJeach batch and reporting periodsame production period and drawing revisionactual site and traceable supplierper 1 kg reference flowcalibration; traceability; uncertainty; reconciliation
cp_residualp_utilitiesone residual streamforeground_recordnamed stream; wet/dry mass; assay; stocks; return; external destination; treatment providerWeigh each segregated waste stream and sample its composition; reconcile internal returns independently of outgoing residuals.kgeach batch and reporting periodsame production period and drawing revisionactual site and traceable supplierper 1 kg reference flowcalibration; traceability; uncertainty; reconciliation
cp_waterp_utilitieswater and effluentforeground_recordsupply; flowmeter; density; copper species; concentration; volume; stock; evaporation; providerUse calibrated meters and matching timed concentration samples; distinguish makeup, internal circulation and actual discharge.kgeach batch and reporting periodsame production period and drawing revisionactual site and traceable supplierper 1 kg reference flowcalibration; traceability; uncertainty; reconciliation
cp_emissionp_utilitiesone emitted speciesforeground_recordspecies; compartment; control state; flow; concentration; measurement duration; factor scope; stock recoveryMeasure post-control discharge or apply a justified species-specific factor with matching activity; retain uncertainty and do not infer CO/NO2 from fuel carbon alone.kgeach batch and reporting periodsame production period and drawing revisionactual site and traceable supplierper 1 kg reference flowcalibration; traceability; uncertainty; reconciliation
cp_packp_dispatchone packing componentforeground_recordcarton/bag identity; composition; received/used mass; supplier; return rateWeigh each actual packing component and reconcile consumed batch packaging; keep it outside reference part net mass.kgeach batch and reporting periodsame production period and drawing revisionactual site and traceable supplierper 1 kg reference flowcalibration; traceability; uncertainty; reconciliation

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
batch_normalizationall inventory rowsDivide attributable batch exchange by calibrated accepted net part batch mass in kg; keep original numerator unit and reject nonpositive denominator. Reference output remains 1 kg.cp_mass; actual batch exchangeexchange per 1 kg reference flow
energy_conversiontest_power; factory_powerMetered kWh multiplied by 3.6 yields MJ before division by accepted net kg. Preserve actual country/voltage/provider and exclude duplicated test consumption.cp_energy; cp_massMJ per kg
contained_speciesmaterial, chemical, residual and emitted-species mass balancesFor each material and chemical use its measured gross amount times matched assay/concentration for contained species; retain opening/closing stocks, reaction retention and actual releases, not a generic common assay.cp_material; cp_chem; cp_residual; cp_emissionseparate species balance

Data Quality Requirements

requirement_idApplies toRequirementEvidence
dq_identityall flowsActual drawing/interface/state and exact supplier grade; UUID type/property/unit/geography checked before adoption. The category-level flow does not supply drawing, site, supplier, geography or specific part qualifications; collect these explicitly.drawing; direct-read identity; supplier scope
dq_coverageall processesRoute ledger records included, not_applicable, zero and unknown separately; candidate source examples establish no universal empirical ranges.route evidence; measured period totals

9. Validation Rules

rule_idApplies toRulesource_ids
validate_scopefinal_partVerify qualifying host and delivered incomplete part, exact revision and remaining assembly; completed optional handsets, modems/routers and ADP network cards cannot be passed as dedicated parts by compatibility alone.cpc3-telecom; panasonic-handset
validate_massall inventory rowsCheck positive calibrated accepted net batch kg, same drawing/BOM/state/period and counted population; reconcile acceptance, reject and rework. Exclude packaging from reference mass and retain numerator units.
validate_balanceall processesClose external gross material inputs plus opening stocks against accepted constituents, external scrap/waste, emissions and closing stocks; cancel paired internal transfers. Separately close each actual Cu,Al,Sn,Ag,Fe and other species using its own matched assay on every term. Include reactions, oxidation, dissolved releases and wet/dry moisture; gross scrap is not contained copper. Close water makeup/stock, discharge, evaporation and carryover; chemical additions/stock, recovery, reaction and residuals. Investigate imbalance against measured uncertainty; no invented fixed tolerances or yields. Fuel carbon may support CO2 with evidence but not establish CO or NO2.
validate_completenessdatasetCheck all real conditional operations and atomic exchanges, make/buy upstream burden once, utility provider/voltage, actual waste fate and emitted species/compartment. Unknown mandatory quantity, unresolved required UUID/provider or unsupported conversion blocks a complete dataset; methodology measurement pass is not apparatus conformity or evidence completion.

10. Published Dataset Profile

FieldValue
dataset_roleforeground_dataset
downstream_usesecondary_dataset; background_dataset
allowed_useMatched part specification/state upstream interface for foreground packages and downstream process/lifecyclemodel construction
excluded_useGeneric complete handset/router model; host use-phase electricity; cross-part functional comparison by kg; unqualified material substitution
required_metadataAll reference qualifiers, actual routes, supplier coverage and allocation
required_quality_disclosureUnresolved identities/providers, measured uncertainties, missing source/range coverage and exact boundaries
update_triggerDrawing/BOM/revision, delivered state, make/buy, supplier, material grade, factory route/test or utility change

11. Data Sources

Source idTypeReferenceUsed for
cpc3-telecomofficial_guidanceUNSD CPC3.0 Explanatory Notes, 30 June 2025, pp257/259; https://unstats.un.org/unsd/classifications/Econ/Download/In%20Text/CPC_Ver_3.0_Exp_Notes_30Jun2025.pdfHost and part taxonomy, complete apparatus and ADP card counter-boundary; no material recipe
apple-enclosurehandbookApple iPhone15/15Plus Enclosure, 10 April2025, Before You Begin/Reassembly; https://support.apple.com/en-gb/120605Delivered enclosure requires logic board, battery, display and other remaining host assembly; example only
apple-connectorhandbookApple iPhone15 USB-C Connector, 3 June2025, Removal/Reassembly; https://support.apple.com/en-gb/122386Dedicated connector flex, host assembly and cleaning identity; not factory quantity factors
cisco-network-modulehandbookCisco Catalyst9500 Hardware Installation Guide, Installing a Network Module; https://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst9500/hardware/install/b_catalyst_9500_hig/9500_installing-network-module.htmlSpecific slot/blank airflow and modular interfaces; active module classification unresolved without completion review
panasonic-handsethandbookPanasonic handset part-number/model compatibility list; https://help.na.panasonic.com/answers/parts-and-accessories-telephone-handset-part-number-to-model-number-compatibility-list/Optional operational handset counterexample: compatibility does not prove incomplete part
taoglas-cellularhandbookTaoglas FXP14.07.0100A Flexible PCB Cellular Antenna, SPE-12-8-050-G, p1; https://cdn.taoglas.com/datasheets/FXP14.07.0100A.pdfPassive cellular flex antenna cable/connector/adhesive integration example, not universal dedication or manufacturing recipe
protolabs-moldinghandbookProtolabs Injection Molding Services, tooling/materials/quality sections; https://www.protolabs.com/services/injection-molding/Conditional plastic forming, resin alternatives and inspection capability; actual supplier grade and operations must be collected
census-electronicsofficial_guidanceUS Census Schedule B2022 Chapter85, headings8517/8534/8536/8541/8542; https://www.census.gov/foreign-trade/schedules/b/2022/c85.htmlIndependent counterevidence for apparatus/parts and separately described generic electronic components; not an automatic CPC mapping
ef-allocation-2021official_guidanceCommission Recommendation(EU)2021/2279, section4.5 pp87–88; https://eur-lex.europa.eu/legal-content/EN/TXT/PDF/?uri=CELEX%3A02021H2279-20211230Allocation hierarchy and demonstrable physical relationship

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 3
Rule IDApplies toRuleSource IDs
boundary_deliveryall processesRequire documented incomplete constituent identity. Host fit alone and absence of stand-alone operation are insufficient; completed apparatus and separately classified components stay outside final output.cpc3-telecom, panasonic-handset, census-electronics
boundary_make_buyall processesFor every BOM line record make/buy, incoming completion, upstream provider coverage and operations performed here. If bought board/antenna/enclosure already embeds copper, polymer and IC manufacture, do not add embedded inputs or operations again. If made here include actual materials, chemistry, waste and energy.apple-enclosure, taoglas-cellular
boundary_factoryall processesInclude attributable fabrication, finish, assembly, rework, acceptance testing, utilities, treatment and packing. Factory RF/continuity tests are production; later telephone calls, data traffic, host installation, repair and end-of-life are outside this production package and require separate declared lifecycle stages.apple-enclosure, cisco-network-module
Allocation rules · 2
Rule IDApplies toRuleSource IDs
allocation_causalityshared factory operationsInvestigate subdivision/system expansion first. If unavoidable, retain total inventories and choose demonstrated physical causality; use actual molding shot/cavity loading, machining time, reflow loading or measured testing demand as appropriate, not part mass merely because output is kg. Other relationships need justification and sensitivity.ef-allocation-2021
allocation_residualscrap and reworkDo not assume sold scrap is a co-product or avoided-primary-material credit. Disclose selected recycling/treatment allocation, provider and fate; cancel internal regrind/return transfers but retain repeated energy and losses. Rejected parts and retests contribute to the accepted output denominator.ef-allocation-2021
Validation rules · 4
Rule IDApplies toRuleSource IDs
validate_scopefinal_partVerify qualifying host and delivered incomplete part, exact revision and remaining assembly; completed optional handsets, modems/routers and ADP network cards cannot be passed as dedicated parts by compatibility alone.cpc3-telecom, panasonic-handset
validate_massall inventory rowsCheck positive calibrated accepted net batch kg, same drawing/BOM/state/period and counted population; reconcile acceptance, reject and rework. Exclude packaging from reference mass and retain numerator units.
validate_balanceall processesClose external gross material inputs plus opening stocks against accepted constituents, external scrap/waste, emissions and closing stocks; cancel paired internal transfers. Separately close each actual Cu,Al,Sn,Ag,Fe and other species using its own matched assay on every term. Include reactions, oxidation, dissolved releases and wet/dry moisture; gross scrap is not contained copper. Close water makeup/stock, discharge, evaporation and carryover; chemical additions/stock, recovery, reaction and residuals. Investigate imbalance against measured uncertainty; no invented fixed tolerances or yields. Fuel carbon may support CO2 with evidence but not establish CO or NO2.
validate_completenessdatasetCheck all real conditional operations and atomic exchanges, make/buy upstream burden once, utility provider/voltage, actual waste fate and emitted species/compartment. Unknown mandatory quantity, unresolved required UUID/provider or unsupported conversion blocks a complete dataset; methodology measurement pass is not apparatus conformity or evidence completion.
Processes and inputs/outputs · 8
Process IDProcess nameInput flowsOutput flows
p_receiptReceipt and upstream interface40
p_mechanicalMechanical forming and machining32
p_polymerPolymer molding and trimming21
p_electronicDedicated electronic or RF subassembly fabrication41
p_finishSurface finishing and cleaning21
p_assemblyPart assembly and acceptance10
p_utilitiesUtilities and pollution control35
p_dispatchPacking and dispatch21

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page