TianGong PCR

Dedicated parts for electronic tubes, semiconductor devices and integrated circuits

Lifecycle status
Candidate
Content maturity
Authored methodology
Current version
No published versionLast updated
Readiness
Review required

Methodology and translation states come from the source record; publishing this website does not change their review status.

Content languages

en-US · canonicalzh-CN · Aligned
Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:47173 · exact

Source

1. Scope and Applicability

This methodology covers externally supplied, dedicated constituent parts for electronic valves/tubes, semiconductor devices including photosensitive/LED devices and mounted piezoelectric crystals, and electronic integrated circuits. Product identity requires a host-use drawing, part number, delivered state and evidence of independent supply. It includes tube electrodes, dispenser cathodes and getters; IC/device leadframes, package substrates and qualified package/feedthrough subassemblies. Functionality or an active surface does not itself exclude a part.

Exclude complete tubes, devices and ICs, generic raw wafers/stock, generic printed circuit boards and manufacturing/test equipment. An unmounted die or wafer is not automatically a part: review whether a completed semiconductor/IC function already exists. Incomplete functional elements remain eligible only with specific part-boundary evidence. Standalone glass envelopes/preforms may belong to a separate glass category; distinguish them from an accepted glass-metal electrical subassembly. Ambiguous glass, die, package substrate/printed circuit, interposer or resonator identities require individual classification and completion-state review, not scope deletion or assumed mapping. Dedicated host fit or SHINKO sale alone does not establish parts-category membership; a substrate that is independently a printed circuit follows its own category. Sources: unsd-cpc3-parts; unsd-cpc21-correspondence; census-semiconductor-state; shinko-package; saes-cathodes.

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.metal-products-machinery-and-equipment.radio-television-and-communication-equipment-and-apparatus.parts-for-the-goods-of-subclasses-47140-to-47160
classification_refsCPC 3.0:47173
covered_productsDedicated parts for electronic tubes, semiconductor devices and integrated circuits
excluded_productsCompleted host devices; generic stock; machinery; independently classified articles
representative_productDrawing-defined accepted IC leadframe; other qualified part types use their own declared identity
production_routeActual metal, laminate/ceramic, powder/getter/cathode or hermetic route with conditional surface operations
market_stateOne independently supplied accepted part state at factory gate

3. Reference Flow

FieldValue
WhatDedicated parts for electronic tubes, semiconductor devices and integrated circuits
How much1 kg
How wellhost product family and principal dedicated use; part number and drawing revision; delivered completion state; material grade and assay; geometry, finish and tolerances; electrical/thermal/vacuum requirements applicable to this part; accepted lot and count; net mass; make/buy route; supplier completed operations; site, period and gate
How long or cycleOne supply at manufacturing gate; no host service life or use-stage performance claim
reference_flow_linkfinal_product
FieldValue
Reference amount1
Reference product flowAccepted drawing-defined dedicated electronic part
Reference flow propertyMass 93a60a56-a3c8-11da-a746-0800200b9a66
Reference unit groupUnits of mass 93a60a57-a4c8-11da-a746-0800200c9a66
Reference unitkg
Required qualifiershost product family and principal dedicated use; part number and drawing revision; delivered completion state; material grade and assay; geometry, finish and tolerances; electrical/thermal/vacuum requirements applicable to this part; accepted lot and count; net mass; make/buy route; supplier completed operations; site, period and gate

D is the positive measured accepted net mass of the same drawing revision and delivered completion state for the reporting period. Exclude shipping carriers, rejected units, test consumables and packaging. Retained metallization, sealing glass and constituent subparts belong in D. One dataset never averages incompatible part identities by mass. A count-based order is converted using measured lot net mass and matched accepted count; no assumed per-part weight is allowed. Reference-product UUID must be resolved for the actual part before interoperable publication.

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
reference_massfinal_productMasskgcp_final_product measures D on calibrated balance; normalize every attributable interval exchange by D.
count_crosscheckfinal_productMasskgRecord accepted count and measured mass for the identical lot/drawing/completion state. Divide lot net mass by its accepted count for order conversion; never use package gross mass or a different part revision.
species_basismaterial and species mass balancesMasskgDistinguish solution/powder/product mass from contained element; retain assay, moisture and active content for every balance term. Preserve electricity energy units; 1 kWh = 3.6 MJ.

5. System Boundary

Boundary Abstraction

FieldValue
declared_starting_conditionReceived stock/powder/laminate/preform or dedicated purchased subpart; disclose completed supplier operations
starting_condition_roleExplicit supplier-to-foreground interface
product_classification_scopeDedicated parts for electronic tubes, semiconductor devices and integrated circuits
recursive_input_rulePurchased same-family parts carry upstream provider burdens once; internal transfers cancel, without deleting repeated processing consumption
upstream_dataset_requirementTrace every feed and purchased utility to actual provider, state, geography/year and represented operations; unresolved links are gaps, never zero
disclosurehost product family and principal dedicated use; part number and drawing revision; delivered completion state; material grade and assay; geometry, finish and tolerances; electrical/thermal/vacuum requirements applicable to this part; accepted lot and count; net mass; make/buy route; supplier completed operations; site, period and gate
rule_idApplies toRulesource_ids
boundary_make_buyall processesCreate a make/buy matrix by part/BOM revision: purchased complete subpart includes embedded materials and supplier operations; in-house route instead collects actual constituent inputs and operations. Outsourced processing includes transport and provider service exactly once.shinko-package; saes-cathodes
boundary_routesall processesInclude actual forming, cleanroom/vacuum, deposition/plating, firing/sealing, rework, part acceptance and controls through gate. Semiconductor wafer fabrication is included only for a proven dedicated-part route or linked upstream provider, never forced onto all leadframes or tube parts.shinko-business; saes-metallurgy
boundary_later_useall processesHost assembly, host operation, customer activation/firing and end of life are outside factory production unless actually performed to deliver the stated part. Disclose capital/maintenance and transport treatment. Add each actual omitted chemical, fuel, gas, waste and species as a separate atomic exchange before dataset completion.

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
receiptDedicated identity, make/buy and receiptrequiredTrace each purchased subpart or raw feed through its drawing and supplier interface.Foreground productionper 1 kg reference flow
metal_formMetal forming and patterningconditionalActual leadframe/electrode/cap: stamping, etching, machining, drawing, cleaning and internal rework.Foreground productionper 1 kg reference flow
substratePackage substrate and insulating bodyconditionalActual organic multilayer or ceramic body: laminate or powder preparation, forming, drilling, patterning and firing; distinguish a purchased finished substrate.Foreground productionper 1 kg reference flow
tube_partTube cathode, getter and sealed componentconditionalActual electrode/getter powder forming, sintering, impregnation/coating, glass preform forming/annealing, glass-metal joining and vacuum preparation as applicable to delivered part.Foreground productionper 1 kg reference flow
finishSurface metallization, plating and joiningconditionalOnly actual part-state operations: deposition, plating, rinse, drying, cure, braze or weld. Record recipe and abatement, not a universal wafer-fabrication chain.Foreground productionper 1 kg reference flow
acceptancePart acceptance and dispatchrequiredDimensional/finish, conductivity, continuity/insulation, hermeticity or emission tests specified for the part; segregate rejects, test consumption and packaging.Foreground productionper 1 kg reference flow
utilitiesFactory utilities and pollution controlsrequiredAttributable purchased energy, water loops, ventilation, vacuum, treatment and maintenance; reconcile shared meters.Foreground productionper 1 kg reference flow

Process: Dedicated identity, make/buy and receipt (receipt)

Inputs

Product flows
Leadframe (purchased_leadframe)

Only externally purchased IC-packaging leadframe matching the declared drawing/material/finish. GLO product identity is not a site provider. Do not adopt a database suggested mass-share estimate or use this UUID for cathodes/substrates.

  • Selected flow: Leadframe 7246f723-e925-4cb4-a861-02b5368fac6d
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_purchased_leadframe
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_purchased_leadframe
  • Sources: shinko-package
Purchased fired alumina ceramic IC-package body (purchased_alumina_body)

Purchase path: supplier already provides forming/firing; add supplier burden and transport once, bypass only completed operations.

  • Selected flow: Purchased fired alumina ceramic IC-package body
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_purchased_alumina_body
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_purchased_alumina_body
  • Sources: shinko-business
Purchased dispenser cathode for microwave tube (purchased_cathode)

Applicable only when present in the actual recipe/BOM; verify absence separately from unknown.

  • Selected flow: Purchased dispenser cathode for microwave tube
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_purchased_cathode
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_purchased_cathode
  • Sources: saes-cathodes
Alternating current (receipt_electricity)

Qualified example for China 1–35 kV consumption mix supplied to user only. Use actual region, voltage and year provider; other interfaces require another verified identity. Never substitute source-specific incinerator or biomass power.

  • Selected flow: Alternating current 3d76981f-964a-4865-b588-0e067a2a1163
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Collected attributable period quantity divided by D; cp_receipt_electricity
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_receipt_electricity
  • Sources: shinko-business
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Elementary flows

Process: Metal forming and patterning (metal_form)

Inputs

Product flows
Copper alloy C19400 strip (c19400_strip)

Example concrete feed only when specified by the actual leadframe drawing; not a mandatory grade or proxy for Alloy42, nickel or molybdenum. Add each actual grade separately.

  • Selected flow: Copper alloy C19400 strip
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_c19400_strip
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_c19400_strip
  • Sources: shinko-business
Iron-nickel Alloy42 strip (alloy42_strip)

Applicable only when present in the actual recipe/BOM; verify absence separately from unknown.

  • Selected flow: Iron-nickel Alloy42 strip
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_alloy42_strip
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_alloy42_strip
  • Sources: shinko-business
Nickel sheet for tube electrode (nickel_sheet)

Applicable only when present in the actual recipe/BOM; verify absence separately from unknown.

  • Selected flow: Nickel sheet for tube electrode
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_nickel_sheet
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_nickel_sheet
  • Sources: shinko-business
Ferric chloride aqueous etchant (ferric_chloride)

Ferric-chloride etch route only; declare solution concentration, dissolved copper/nickel loading and regeneration. Another etchant needs its own chemical row.

  • Selected flow: Ferric chloride aqueous etchant
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_ferric_chloride
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_ferric_chloride
  • Sources: shinko-business
Alternating current (metal_form_electricity)

Qualified example for China 1–35 kV consumption mix supplied to user only. Use actual region, voltage and year provider; other interfaces require another verified identity. Never substitute source-specific incinerator or biomass power.

  • Selected flow: Alternating current 3d76981f-964a-4865-b588-0e067a2a1163
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Collected attributable period quantity divided by D; cp_metal_form_electricity
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_metal_form_electricity
  • Sources: shinko-business
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Copper-alloy C19400 stamping scrap (metal_scrap)

Applicable only when present in the actual recipe/BOM; verify absence separately from unknown.

  • Selected flow: Copper-alloy C19400 stamping scrap
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_metal_scrap
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_metal_scrap
  • Sources: shinko-business
Elementary flows

Process: Package substrate and insulating body (substrate)

Inputs

Product flows
Alumina powder for ceramic package body (alumina_powder)

Applicable only when present in the actual recipe/BOM; verify absence separately from unknown.

  • Selected flow: Alumina powder for ceramic package body
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_alumina_powder
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_alumina_powder
  • Sources: shinko-business
Copper-clad epoxy glass laminate for IC package substrate (epoxy_glass_laminate)

Purchased laminate includes supplier copper/resin/glass production; in-house layup replaces it with separate actual copper foil, resin and reinforcement inputs. No duplicate embedded-material entries.

  • Selected flow: Copper-clad epoxy glass laminate for IC package substrate
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_epoxy_glass_laminate
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_epoxy_glass_laminate
  • Sources: shinko-business
Copper foil for package substrate wiring (copper_foil)

Applicable only when present in the actual recipe/BOM; verify absence separately from unknown.

  • Selected flow: Copper foil for package substrate wiring
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_copper_foil
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_copper_foil
  • Sources: shinko-business
Epoxy resin for package substrate dielectric (epoxy_resin)

Applicable only when present in the actual recipe/BOM; verify absence separately from unknown.

  • Selected flow: Epoxy resin for package substrate dielectric
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_epoxy_resin
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_epoxy_resin
  • Sources: shinko-business
Alternating current (substrate_electricity)

Qualified example for China 1–35 kV consumption mix supplied to user only. Use actual region, voltage and year provider; other interfaces require another verified identity. Never substitute source-specific incinerator or biomass power.

  • Selected flow: Alternating current 3d76981f-964a-4865-b588-0e067a2a1163
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Collected attributable period quantity divided by D; cp_substrate_electricity
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_substrate_electricity
  • Sources: shinko-business
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Elementary flows

Process: Tube cathode, getter and sealed component (tube_part)

Inputs

Product flows
Tungsten powder for porous cathode body (tungsten_powder)

Applicable only when present in the actual recipe/BOM; verify absence separately from unknown.

  • Selected flow: Tungsten powder for porous cathode body
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_tungsten_powder
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_tungsten_powder
  • Sources: saes-metallurgy
Zirconium-vanadium-iron getter alloy powder (getter_alloy)

Only if actual getter formulation specifies this alloy; record constituent fractions and oxygen contamination; barium-based evaporative getter is a separate route and flow.

  • Selected flow: Zirconium-vanadium-iron getter alloy powder
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_getter_alloy
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_getter_alloy
  • Sources: saes-metallurgy
Barium-calcium aluminate cathode impregnant (barium_aluminate)

Only supplier-defined formulated impregnant in actual dispenser-cathode recipe; obtain assay, binder and batch composition rather than guessing stoichiometry.

  • Selected flow: Barium-calcium aluminate cathode impregnant
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_barium_aluminate
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_barium_aluminate
  • Sources: saes-metallurgy
Borosilicate glass sealing preform (glass_preform)

Purchased preform for actual hermetic component; declare glass grade, expansion compatibility and supplier completed melting/forming. If made on site, replace with each actual batch ingredient and retain melt/anneal burdens. Standalone glass envelope is not automatically a mapped device part.

  • Selected flow: Borosilicate glass sealing preform
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_glass_preform
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_glass_preform
  • Sources: saes-metallurgy
Iron-nickel-cobalt Kovar pin for hermetic feedthrough (kovar_pin)

Applicable only when present in the actual recipe/BOM; verify absence separately from unknown.

  • Selected flow: Iron-nickel-cobalt Kovar pin for hermetic feedthrough
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_kovar_pin
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_kovar_pin
  • Sources: saes-metallurgy
Alternating current (tube_part_electricity)

Qualified example for China 1–35 kV consumption mix supplied to user only. Use actual region, voltage and year provider; other interfaces require another verified identity. Never substitute source-specific incinerator or biomass power.

  • Selected flow: Alternating current 3d76981f-964a-4865-b588-0e067a2a1163
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Collected attributable period quantity divided by D; cp_tube_part_electricity
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_tube_part_electricity
  • Sources: saes-metallurgy
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Elementary flows

Process: Surface metallization, plating and joining (finish)

Inputs

Product flows
Nickel sulfate aqueous plating solution (nickel_sulfate)

Only actual nickel plating; separate nickel salt, additives and anode when supplied separately; measure nickel species balance without equating solution mass with nickel.

  • Selected flow: Nickel sulfate aqueous plating solution
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_nickel_sulfate
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_nickel_sulfate
  • Sources: shinko-business
Silver deposition target (silver_target)

Applicable only when present in the actual recipe/BOM; verify absence separately from unknown.

  • Selected flow: Silver deposition target
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_silver_target
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_silver_target
  • Sources: shinko-business
Hydrochloric acid aqueous cleaning solution (hydrochloric_acid)

Applicable only when present in the actual recipe/BOM; verify absence separately from unknown.

  • Selected flow: Hydrochloric acid aqueous cleaning solution
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_hydrochloric_acid
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_hydrochloric_acid
  • Sources: shinko-business
Isopropanol cleaning solvent (isopropanol)

Applicable only when present in the actual recipe/BOM; verify absence separately from unknown.

  • Selected flow: Isopropanol cleaning solvent
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_isopropanol
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_isopropanol
  • Sources: shinko-business
Nitrogen process gas (nitrogen)

Applicable only when present in the actual recipe/BOM; verify absence separately from unknown.

  • Selected flow: Nitrogen process gas
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_nitrogen
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_nitrogen
  • Sources: shinko-business
Alternating current (finish_electricity)

Qualified example for China 1–35 kV consumption mix supplied to user only. Use actual region, voltage and year provider; other interfaces require another verified identity. Never substitute source-specific incinerator or biomass power.

  • Selected flow: Alternating current 3d76981f-964a-4865-b588-0e067a2a1163
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Collected attributable period quantity divided by D; cp_finish_electricity
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_finish_electricity
  • Sources: shinko-business
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Nickel-bearing plating sludge (plating_sludge)

Applicable only when present in the actual recipe/BOM; verify absence separately from unknown.

  • Selected flow: Nickel-bearing plating sludge
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_plating_sludge
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_plating_sludge
  • Sources: shinko-business
Elementary flows
Isopropanol to air (ipa_air)

Applicable only when present in the actual recipe/BOM; verify absence separately from unknown.

  • Selected flow: Isopropanol to air
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_ipa_air
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_ipa_air
  • Sources: shinko-business

Process: Part acceptance and dispatch (acceptance)

Inputs

Product flows
Helium leak-test gas (helium)

Only actual hermetic part tests; include consumed gas and failed/destructively tested parts, not a fictitious complete-tube lifetime test.

  • Selected flow: Helium leak-test gas
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_helium
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_helium
  • Sources: shinko-business
Polyethylene antistatic shipping bag (polyethylene_bag)

Applicable only when present in the actual recipe/BOM; verify absence separately from unknown.

  • Selected flow: Polyethylene antistatic shipping bag
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_polyethylene_bag
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_polyethylene_bag
  • Sources: shinko-business
Corrugated fibreboard shipping box (corrugated_box)

Applicable only when present in the actual recipe/BOM; verify absence separately from unknown.

  • Selected flow: Corrugated fibreboard shipping box
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_corrugated_box
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_corrugated_box
  • Sources: shinko-business
Alternating current (acceptance_electricity)

Qualified example for China 1–35 kV consumption mix supplied to user only. Use actual region, voltage and year provider; other interfaces require another verified identity. Never substitute source-specific incinerator or biomass power.

  • Selected flow: Alternating current 3d76981f-964a-4865-b588-0e067a2a1163
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Collected attributable period quantity divided by D; cp_acceptance_electricity
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_acceptance_electricity
  • Sources: shinko-business
Waste flows
Elementary flows

Outputs

Product flows
Accepted drawing-defined dedicated electronic part (final_product)

Bind this output to exactly one actual drawing-defined part identity and its actual delivered state in the concrete dataset. A leadframe, substrate, electrode/cathode, getter assembly or hermetic subassembly each requires its own verified reference identity. Split different part numbers/completion states into separate output rows and datasets; this row is not a material basket or a licence to use a leadframe UUID for the family.

  • Selected flow: Accepted drawing-defined dedicated electronic part
  • Flow property / unit: Mass / kg
  • Amount rule: 1 kg
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_final_product
  • Sources: shinko-package
Waste flows
Elementary flows

Process: Factory utilities and pollution controls (utilities)

Inputs

Product flows
Alternating current (utilities_electricity)

Qualified example for China 1–35 kV consumption mix supplied to user only. Use actual region, voltage and year provider; other interfaces require another verified identity. Never substitute source-specific incinerator or biomass power.

  • Selected flow: Alternating current 3d76981f-964a-4865-b588-0e067a2a1163
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Collected attributable period quantity divided by D; cp_utilities_electricity
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_utilities_electricity
  • Sources: shinko-business
Natural gas for furnace combustion (natural_gas)

Applicable only when present in the actual recipe/BOM; verify absence separately from unknown.

  • Selected flow: Natural gas for furnace combustion
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Collected attributable period quantity divided by D; cp_natural_gas
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_natural_gas
  • Sources: shinko-business
Purchased process steam (steam)

Applicable only when present in the actual recipe/BOM; verify absence separately from unknown.

  • Selected flow: Purchased process steam
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Collected attributable period quantity divided by D; cp_steam
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_steam
  • Sources: shinko-business
Purchased deionized process water (water)

Applicable only when present in the actual recipe/BOM; verify absence separately from unknown.

  • Selected flow: Purchased deionized process water
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_water
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_water
  • Sources: shinko-business
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Copper-bearing process wastewater to treatment (wastewater)

Applicable only when present in the actual recipe/BOM; verify absence separately from unknown.

  • Selected flow: Copper-bearing process wastewater to treatment
  • Flow property / unit: Volume / m3
  • Amount rule: Collected attributable period quantity divided by D; cp_wastewater
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_wastewater
  • Sources: shinko-business
Elementary flows
Carbon dioxide, fossil, to air (co2_air)

Applicable only when present in the actual recipe/BOM; verify absence separately from unknown.

  • Selected flow: Carbon dioxide, fossil, to air
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_co2_air
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_co2_air
  • Sources: shinko-business
Nitrogen oxides, as NO2, to air (nox_air)

Applicable only when present in the actual recipe/BOM; verify absence separately from unknown.

  • Selected flow: Nitrogen oxides, as NO2, to air
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_nox_air
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_nox_air
  • Sources: shinko-business
Carbon monoxide to air (co_air)

Applicable only when present in the actual recipe/BOM; verify absence separately from unknown.

  • Selected flow: Carbon monoxide to air
  • Flow property / unit: Mass / kg
  • Amount rule: Collected attributable period quantity divided by D; cp_co_air
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_co_air
  • Sources: shinko-business

7. Allocation and Co-product Handling

rule_idApplies toRulesource_ids
allocation_subdivideall processesSeparate dedicated lots/operations before allocation. Assign shared furnace, cleanroom, vacuum and treatment demand using measured machine occupancy/load, area-time or pollutant load that explains consumption; disclose causal basis and uncertainty. Avoid mass allocation between unrelated part technologies.
allocation_reworkall processesRetain rejects, destructive tests and repeated processing in attributable inputs; only accepted net saleable parts enter D. Recovered metal/solvent is not a burden-free product or automatic avoided-production credit. Declare waste versus co-product status and chosen modelling convention without mixing them.

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_purchased_leadframereceiptpurchased_leadframeproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh receipts, issue and return, reconcile opening/closing stocks and lot assay; record actual grade, state and provider.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_purchased_alumina_bodyreceiptpurchased_alumina_bodyproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh receipts, issue and return, reconcile opening/closing stocks and lot assay; record actual grade, state and provider.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_purchased_cathodereceiptpurchased_cathodeproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh receipts, issue and return, reconcile opening/closing stocks and lot assay; record actual grade, state and provider.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_c19400_stripmetal_formc19400_stripproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh receipts, issue and return, reconcile opening/closing stocks and lot assay; record actual grade, state and provider.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_alloy42_stripmetal_formalloy42_stripproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh receipts, issue and return, reconcile opening/closing stocks and lot assay; record actual grade, state and provider.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_nickel_sheetmetal_formnickel_sheetproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh receipts, issue and return, reconcile opening/closing stocks and lot assay; record actual grade, state and provider.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_ferric_chloridemetal_formferric_chlorideproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh receipts, issue and return, reconcile opening/closing stocks and lot assay; record actual grade, state and provider.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_alumina_powdersubstratealumina_powderproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh receipts, issue and return, reconcile opening/closing stocks and lot assay; record actual grade, state and provider.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_epoxy_glass_laminatesubstrateepoxy_glass_laminateproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh receipts, issue and return, reconcile opening/closing stocks and lot assay; record actual grade, state and provider.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_copper_foilsubstratecopper_foilproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh receipts, issue and return, reconcile opening/closing stocks and lot assay; record actual grade, state and provider.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_epoxy_resinsubstrateepoxy_resinproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh receipts, issue and return, reconcile opening/closing stocks and lot assay; record actual grade, state and provider.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_tungsten_powdertube_parttungsten_powderproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh receipts, issue and return, reconcile opening/closing stocks and lot assay; record actual grade, state and provider.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_getter_alloytube_partgetter_alloyproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh receipts, issue and return, reconcile opening/closing stocks and lot assay; record actual grade, state and provider.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_barium_aluminatetube_partbarium_aluminateproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh receipts, issue and return, reconcile opening/closing stocks and lot assay; record actual grade, state and provider.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_glass_preformtube_partglass_preformproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh receipts, issue and return, reconcile opening/closing stocks and lot assay; record actual grade, state and provider.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_kovar_pintube_partkovar_pinproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh receipts, issue and return, reconcile opening/closing stocks and lot assay; record actual grade, state and provider.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_nickel_sulfatefinishnickel_sulfateproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh receipts, issue and return, reconcile opening/closing stocks and lot assay; record actual grade, state and provider.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_silver_targetfinishsilver_targetproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh receipts, issue and return, reconcile opening/closing stocks and lot assay; record actual grade, state and provider.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_hydrochloric_acidfinishhydrochloric_acidproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh receipts, issue and return, reconcile opening/closing stocks and lot assay; record actual grade, state and provider.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_isopropanolfinishisopropanolproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh receipts, issue and return, reconcile opening/closing stocks and lot assay; record actual grade, state and provider.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_nitrogenfinishnitrogenproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh receipts, issue and return, reconcile opening/closing stocks and lot assay; record actual grade, state and provider.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_heliumacceptanceheliumproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh receipts, issue and return, reconcile opening/closing stocks and lot assay; record actual grade, state and provider.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_polyethylene_bagacceptancepolyethylene_bagproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh receipts, issue and return, reconcile opening/closing stocks and lot assay; record actual grade, state and provider.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_corrugated_boxacceptancecorrugated_boxproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh receipts, issue and return, reconcile opening/closing stocks and lot assay; record actual grade, state and provider.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_receipt_electricityreceiptreceipt_electricityproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DSubmeter actual operation, idle and rework consumption; reconcile total purchased electricity and allocate measured shared load once. Keep kWh record and convert exactly to MJ.MJEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_metal_form_electricitymetal_formmetal_form_electricityproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DSubmeter actual operation, idle and rework consumption; reconcile total purchased electricity and allocate measured shared load once. Keep kWh record and convert exactly to MJ.MJEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_substrate_electricitysubstratesubstrate_electricityproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DSubmeter actual operation, idle and rework consumption; reconcile total purchased electricity and allocate measured shared load once. Keep kWh record and convert exactly to MJ.MJEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_tube_part_electricitytube_parttube_part_electricityproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DSubmeter actual operation, idle and rework consumption; reconcile total purchased electricity and allocate measured shared load once. Keep kWh record and convert exactly to MJ.MJEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_finish_electricityfinishfinish_electricityproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DSubmeter actual operation, idle and rework consumption; reconcile total purchased electricity and allocate measured shared load once. Keep kWh record and convert exactly to MJ.MJEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_acceptance_electricityacceptanceacceptance_electricityproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DSubmeter actual operation, idle and rework consumption; reconcile total purchased electricity and allocate measured shared load once. Keep kWh record and convert exactly to MJ.MJEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_utilities_electricityutilitiesutilities_electricityproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DSubmeter actual operation, idle and rework consumption; reconcile total purchased electricity and allocate measured shared load once. Keep kWh record and convert exactly to MJ.MJEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_natural_gasutilitiesnatural_gasproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DMeter supplier volume at recorded conditions and use measured net calorific value; separate purchased heat from own furnace gas.MJEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_steamutilitiessteamproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DMeasure steam flow and inlet/return enthalpy; retain pressure, temperature and condensate return boundary.MJEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_waterutilitieswaterproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DMeter fresh supply and separately record internal circulation, treatment and blowdown; do not multiply loop circulation as purchased demand.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_metal_scrapmetal_formmetal_scrapproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh external scrap by grade, oxidation/coating and destination; internal return cancels in site balance and retains reprocessing burdens.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_plating_sludgefinishplating_sludgeproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh wet sludge; measure dry solids and nickel assay on same moisture basis, destination and treatment.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_wastewaterutilitieswastewaterproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DMeasure external treatment transfer volume and matched copper/chemical assays. If treated on site, record treatment inputs and residuals, then actual elementary discharges separately.m3Each lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_ipa_airfinishipa_airproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DSpecies-specific exhaust/fugitive monitoring or validated solvent balance with recovered stocks and controls; do not turn total VOC into this species.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_co2_airutilitiesco2_airproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DUse actual fuel carbon assays, oxidation and captured/other carbon streams or matched stack measurements; fossil carbon only.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_nox_airutilitiesnox_airproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DMatched concentration, gas flow, operating hours and reporting species after controls; fuel carbon balance cannot establish NOx.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_co_airutilitiesco_airproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DMatched species monitoring after controls; fuel carbon balance alone cannot establish CO.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation
cp_final_productacceptancefinal_productproduction_recordlot; drawing revision; completion state; amount; unit; assay/conditions; opening/closing stock; accepted net output DWeigh accepted net parts on calibrated balance by drawing revision/lot; tare transport carrier/reel/packaging unless physically retained in sold part. Reconcile count and acceptance register.kgEach lot and meter intervalMatched representative reporting period with startup, idle, reject and rework coverageDeclared process and attributable shared servicesper 1 kg reference flowCalibration; assay; supplier interface; acceptance and stock reconciliation

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
period_normalizationall inventory rowsDivide each attributable interval exchange by matched positive accepted net output D; output reference is 1 kg.D; interval quantity; applicable protocolExchange per 1 kg reference flow
count_conversionfinal_productMatched lot net mass / matched accepted count gives order conversion mass; do not use a catalog typical weight.cp_final_product; count; drawing revisionMeasured same-state count-to-mass relation
element_balancemetal_form; finish; tube_partFor each element: external input plus opening stock equals product retention plus external residues/emissions plus closing stock within measured uncertainty. Use every stream mass times its matched elemental assay; cancel paired internal transfers. For chemical species, include measured reaction consumption/formation and recovered stocks.mass; matched assay; stocks; reaction; uncertaintyReviewed elemental/species closure
energy_conversionelectricity rowsMultiply measured kWh by 3.6 for MJ; separate purchased utilities from in-house generation and allocate own generation fuel/control burdens once.meter; unit; providerMJ on declared supply interface

Data Quality Requirements

requirement_idApplies toRequirementEvidence
identityfinal_producthost product family and principal dedicated use; part number and drawing revision; delivered completion state; material grade and assay; geometry, finish and tolerances; electrical/thermal/vacuum requirements applicable to this part; accepted lot and count; net mass; make/buy route; supplier completed operations; site, period and gateOrder; drawing; host use; supplier catalogue; acceptance
completenessall processesMaintain finite route/flow checklist: applicable measured, applicable unknown, verified not_applicable. Unknown never equals zero; include actual gases, emissions, cleaning and treatment rows beyond examples.Route traveller; BOM; meter; safety data; discharge audit
uncertaintyall exchangesNo universal yield, mass, energy, emissions, lifetime or GWP range is prescribed. Use actual foreground distributions and uncertainty; disclose missing empirical bounds.Calibrated records and explicit gap register

9. Validation Rules

rule_idApplies toRulesource_ids
validate_partfinal_productConfirm dedicated host/part use, drawing revision and delivered completion state. Review finished die/device and glass/equipment counterexamples individually; reject unresolved classification assumptions for a concrete dataset.unsd-cpc3-parts; census-semiconductor-state
validate_denominatorall inventory rowsRequire positive calibrated accepted D, identical reporting scope and per-kg basis in both languages; reconcile counts, test rejects, carrier tare and retained finish.
validate_balanceall processesCheck elemental/species/water/stock closure with documented measurement uncertainty; gross sludge or bath mass cannot equal contained metal. Retain reaction and internal-transfer evidence. CO and NOx require independent species evidence.
validate_providerall exchangesVerify product/waste/elementary type, specific identity, property/unit and provider interface; UUID name alone does not justify grade, mass share, geography or process burden. Unresolved actual-part UUID and missing empirical ranges remain disclosed publication gaps.
validate_routeall processesConfirm every make/buy operation once, actual part-state tests and factory-only utilities; distinguish verified absence from zero measurement and unknown. A skipped applicable route or missing provider means incomplete data.

10. Published Dataset Profile

FieldValue
dataset_roleForeground production package for one qualified dedicated part
downstream_usesecondary_dataset; background_dataset; process; lifecyclemodel
allowed_useSupply of same declared part identity/state for host assembly
excluded_useUnqualified category average; completed device production; host lifetime/use impact
required_metadatahost product family and principal dedicated use; part number and drawing revision; delivered completion state; material grade and assay; geometry, finish and tolerances; electrical/thermal/vacuum requirements applicable to this part; accepted lot and count; net mass; make/buy route; supplier completed operations; site, period and gate
required_quality_disclosureProvider/UUID, range, route, balance and measurement gaps; source scope; conditional absences; allocation uncertainty
update_triggerDrawing/material/state/route/provider change, measured yield or process-control change

11. Data Sources

Source idTypeReferenceUsed for
unsd-cpc3-partsofficial_guidanceUNSD CPC 3.0 Explanatory Notes, 30 June 2025, printed pages255–256, classes4714–4717. https://unstats.un.org/unsd/classifications/Econ/Download/In%20Text/CPC_Ver_3.0_Exp_Notes_30Jun2025.pdf; current detail https://unstats.un.org/unsd/classifications/Econ/Structure/Detail/EN/2100/47173Current host titles and parts category; PDF and online record contain no detailed inclusion/exclusion prose for47173.
unsd-cpc21-correspondenceofficial_guidanceUNSD CPC 2.1, subclass 47173, correspondence to HS 2012/2017. https://unstats.un.org/unsd/classifications/Econ/Detail/EN/1074/47173Historical parts-heading corroboration, HS854091/854099/854190/854290; not asserted to be a current CPC3 correspondence table.
census-semiconductor-stateofficial_guidanceUS Census, Schedule B 2022, Chapter 85, notes and headings 8540–8542. https://www.census.gov/foreign-trade/schedules/b/2022/c85.htmlCounterevidence: unmounted chips/dice/wafers can already be devices; standalone glass articles and manufacturing equipment require separate classification. Historical US schedule, not current legal advice.
shinko-packageextension_guidanceSHINKO, Semiconductor Package, product catalogue, undated. https://www.shinko.co.jp/english/product/package/Sold leadframe, package-substrate and hermetic component interfaces; IC assembly is distinct.
shinko-businessextension_guidanceSHINKO, Our Business, products and core technologies, undated. https://www.shinko.co.jp/english/corporate/business/Conditional stamping/etching, plating, multilayer, ceramic and sealing routes; chucks are equipment parts, not automatically device parts. No intensity, recipe or universal route inferred.
saes-cathodesextension_guidanceSAES/Spectra-Mat, Thermal Management and Cathodes, undated. https://www.saesgetters.com/industrial-thermal-management-cathodes/Independent evidence for functional dispenser cathodes, getter and thermal components with several end uses; tube/semiconductor dedication must be documented.
saes-metallurgyextension_guidanceSAES Industrial, metallurgy capabilities, undated. https://www.saesgetters.com/industrial/Conditional powder forming, sintering and alloy routes only; supplier capability does not establish a particular part recipe or firing schedule.

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 3
Rule IDApplies toRuleSource IDs
boundary_make_buyall processesCreate a make/buy matrix by part/BOM revision: purchased complete subpart includes embedded materials and supplier operations; in-house route instead collects actual constituent inputs and operations. Outsourced processing includes transport and provider service exactly once.shinko-package, saes-cathodes
boundary_routesall processesInclude actual forming, cleanroom/vacuum, deposition/plating, firing/sealing, rework, part acceptance and controls through gate. Semiconductor wafer fabrication is included only for a proven dedicated-part route or linked upstream provider, never forced onto all leadframes or tube parts.shinko-business, saes-metallurgy
boundary_later_useall processesHost assembly, host operation, customer activation/firing and end of life are outside factory production unless actually performed to deliver the stated part. Disclose capital/maintenance and transport treatment. Add each actual omitted chemical, fuel, gas, waste and species as a separate atomic exchange before dataset completion.
Allocation rules · 2
Rule IDApplies toRuleSource IDs
allocation_subdivideall processesSeparate dedicated lots/operations before allocation. Assign shared furnace, cleanroom, vacuum and treatment demand using measured machine occupancy/load, area-time or pollutant load that explains consumption; disclose causal basis and uncertainty. Avoid mass allocation between unrelated part technologies.
allocation_reworkall processesRetain rejects, destructive tests and repeated processing in attributable inputs; only accepted net saleable parts enter D. Recovered metal/solvent is not a burden-free product or automatic avoided-production credit. Declare waste versus co-product status and chosen modelling convention without mixing them.
Validation rules · 5
Rule IDApplies toRuleSource IDs
validate_partfinal_productConfirm dedicated host/part use, drawing revision and delivered completion state. Review finished die/device and glass/equipment counterexamples individually; reject unresolved classification assumptions for a concrete dataset.unsd-cpc3-parts, census-semiconductor-state
validate_denominatorall inventory rowsRequire positive calibrated accepted D, identical reporting scope and per-kg basis in both languages; reconcile counts, test rejects, carrier tare and retained finish.
validate_balanceall processesCheck elemental/species/water/stock closure with documented measurement uncertainty; gross sludge or bath mass cannot equal contained metal. Retain reaction and internal-transfer evidence. CO and NOx require independent species evidence.
validate_providerall exchangesVerify product/waste/elementary type, specific identity, property/unit and provider interface; UUID name alone does not justify grade, mass share, geography or process burden. Unresolved actual-part UUID and missing empirical ranges remain disclosed publication gaps.
validate_routeall processesConfirm every make/buy operation once, actual part-state tests and factory-only utilities; distinguish verified absence from zero measurement and unknown. A skipped applicable route or missing provider means incomplete data.
Processes and inputs/outputs · 7
Process IDProcess nameInput flowsOutput flows
receiptDedicated identity, make/buy and receipt40
metal_formMetal forming and patterning51
substratePackage substrate and insulating body50
tube_partTube cathode, getter and sealed component60
finishSurface metallization, plating and joining62
acceptancePart acceptance and dispatch41
utilitiesFactory utilities and pollution controls44

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.