TianGong PCR产品类别规则

Electrical transformers

Electrical transformers: This PCR applies to the manufacture of complete electrical transformers, including liquid-immersed, dry-type, conventional…

Lifecycle status
Candidate
Content maturity
Authored methodology
Current version
No published version
Readiness
Review required
Last updated

Methodology and translation states come from the source record; publishing this website does not change their review status.

Content languages

zh-CN · Aligned
Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:46121 · exact

Source

1. Scope and Applicability

This PCR applies to the manufacture of complete electrical transformers, including liquid-immersed, dry-type, conventional electrical-steel-core, and amorphous-core designs. It provides a common factory-gate data-production rule across power, distribution, instrument, isolation, control, welding, testing, and other transformer applications when the product remains an electrical transformer.

The foreground boundary begins with purchased materials, purchased transformer subassemblies, water, fuels, gases, and electricity at the manufacturing site and ends with one finished, factory-tested transformer ready to leave the factory. Static converters, ballasts, stand-alone inductors, stand-alone transformer parts, installation, use-phase electricity losses, maintenance, refurbishment, and end-of-life treatment are outside this foreground dataset. A study may model those stages downstream, but it must not merge them into the factory manufacturing inventory.

The product-specific bill of materials and route determine which conditional rows apply. A foreground data package must add any further concrete atomic exchange that crosses the actual site boundary; this PCR's listed rows are the minimum common set and may not be replaced by umbrella labels.

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.metal-products-machinery-and-equipment.electrical-machinery-and-apparatus.electrical-transformers
classification_refsCPC 3.0: 46121 Electrical transformers
covered_productsComplete electrical transformers that transform voltage and current by electromagnetic induction, including liquid-immersed and dry-type products and application-specific transformer designs
excluded_productsStatic converters, ballasts, stand-alone inductors, stand-alone transformer parts, substations and construction works, and contract manufacturing services without ownership of the finished transformer
representative_productOne complete factory-tested electrical transformer configured to the declared rated power, voltage ratio, frequency, phase count, insulation and cooling system, and application
production_routePurchased material and subassembly receipt; core and winding manufacture; insulation and enclosure or tank assembly; route-specific drying, casting, liquid filling, cleaning and finishing; final assembly and factory testing
market_stateFinished, factory-tested, unpackaged transformer at the manufacturer's gate before outbound transport, installation, use, or end-of-life

3. Reference Flow

FieldValue
WhatTransform an alternating-voltage and current system into another declared alternating-voltage and current system by electromagnetic induction for transmission, distribution, supply, measurement, control, isolation, testing, welding, or another declared transformer application
How muchProvide the declared rated apparent power in kVA under the declared operating and loading profile
How wellMeet the declared voltage ratio, frequency, phase count, insulation and cooling technology, no-load loss, load loss, impedance, temperature-rise, and applicable performance or conformity requirements
How long or cycleOperate for the declared reference service life and declared lifetime operating hours or duty cycles; the manufacturing dataset itself ends at the factory gate
reference_flow_linkOne complete factory-tested transformer required to provide the declared function
FieldValue
Reference amount1 Item(s)
Reference product flowTransformer 734249ea-34e6-471b-a05a-f5b26b818167
Reference flow propertyNumber of items 01846770-4cfe-4a25-8ad9-919d8d378345
Reference unit groupUnits of items 5beb6eed-33a9-47b8-9ede-1dfe8f679159
Reference unitItem(s)
Required qualifierstransformer application; rated apparent power; primary and secondary rated voltages; frequency; phase count; winding conductor metal; magnetic-core technology and grade; liquid-immersed or dry-type insulation system; cooling method; no-load and load losses and their test conditions; impedance; total product mass; factory location and production period; reference service life; lifetime operating and loading profile; included accessories and unpackaged factory-gate state

When constructing a foreground data package, every required qualifier must be declared in dataset metadata, process notes, the reference flow comment, the product description, or an equivalent field. The Tiangong reference product supplies category identity only; it does not encode product rating, technology, geography, performance, or service life.

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
reference_item_countFinished transformer reference flowNumber of items 01846770-4cfe-4a25-8ad9-919d8d378345Item(s)Record exactly one accepted, factory-tested transformer as the quantitative reference; report its measured total mass separately as a required qualifier.
material_mass_balanceMaterial inputs and solid or liquid wastesMass 93a60a56-a3c8-11da-a746-0800200b9a66kgWeigh or derive mass from traceable receipts and product-specific issue and return records; reconcile input material with incorporated mass, recoverable scrap, other documented loss, and stock change without forcing unlike materials into one balance.
electricity_energy_basisPurchased electricityNet calorific value 93a60a56-a3c8-11da-a746-0800200b9a66MJPreserve metered electrical energy and convert kWh to MJ only by multiplying by 3.6; exclude use-phase transformer losses and state the meter boundary and loss treatment.
gas_volume_basisNatural gas and industrial oxygenVolume 93a60a56-a3c8-22da-a746-0800200c9a66m3Record delivered or metered volume at declared reference temperature and pressure; do not combine the two gases or convert mass and volume without a documented composition and conversion basis.
factory_test_separationFactory acceptance and routine testingMeasured energy and electrical test resultsMJ; W; kVA; V; HzRecord test-bay electricity in manufacturing electricity, while no-load and load-loss results remain product-performance metadata and must not be added as manufacturing energy.

5. System Boundary

Boundary Abstraction

FieldValue
declared_starting_conditionPurchased materials, purchased transformer subassemblies, water, fuels, gases, and electricity as received at the declared manufacturing site
starting_condition_roleUpstream production is represented by supplier or background datasets; the foreground starts when each input crosses the manufacturing-site boundary
product_classification_scopeComplete electrical transformers; not static converters, ballasts, stand-alone inductors, stand-alone parts, substations, or contract manufacturing services
recursive_input_ruleA purchased complete transformer entering the factory is recorded as an upstream transformer product only when it is physically incorporated or transformed; it must not be recursively remodelled inside this manufacturing process, and its supplier dataset and treatment must be disclosed
upstream_dataset_requirementUse geographically, technologically, temporally, and product-state-representative supplier or background datasets for every purchased input, with explicit treatment of recycled content and allocation
disclosureDeclare site, production period, transformer design and rating, bill-of-materials coverage, core and winding technologies, insulation and cooling system, included accessories, factory test scope, meter boundaries, stock changes, scrap destinations, direct emissions, and all exclusions
rule_idapplies_torulesource_ids
boundary_factory_gateforeground manufacturingInclude material preparation, core and winding manufacture, insulation and structural assembly, applicable drying or casting or liquid filling, cleaning and finishing, final assembly, and factory testing through acceptance of the finished transformer at the factory gate.ec-transformer-impact-assessment-2014
boundary_variant_disclosureproduct and route selectionDistinguish liquid-immersed and dry-type insulation systems and conventional electrical-steel and amorphous-core routes; include each conditional atomic exchange only when the declared product and site records demonstrate that route.eu-power-transformers-regulation-548-2014, ec-transformer-impact-assessment-2014
boundary_downstream_exclusiondownstream lifecycle stagesExclude outbound transport, installation, use-phase electricity losses, maintenance, refurbishment, and end-of-life from this factory-gate foreground inventory; model them as separate downstream processes when the study goal requires them.ec-transformer-impact-assessment-2014

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
transformer_manufacturingElectrical-transformer manufacturing and factory testingrequiredAlways included for a factory-gate transformer datasetForeground production1 accepted factory-tested transformer
transformer_useTransformer operationexcluded_by_defaultModel downstream only when the study goal extends beyond the factory gateDownstream useDeclared operating and loading profile
transformer_end_of_lifeTransformer decommissioning and treatmentexcluded_by_defaultModel downstream only when the study goal extends beyond the factory gateDownstream end-of-lifeDeclared treatment scenario

Process: Electrical-transformer manufacturing and factory testing (transformer_manufacturing)

Inputs

Product flows
Grain-oriented electrical steel for a conventional magnetic core (grain_oriented_electrical_steel)

Record one specific grain-oriented electrical-steel sheet or strip input used in the manufactured core. This row is conditional on a conventional grain-oriented electrical-steel core and is omitted for an amorphous-core design.

  • Selected flow: Grain-oriented electrical steel sheet
  • Flow property / unit: Mass / kg
  • Amount rule: Product-specific issued mass less traceable unused returns, normalized to one accepted transformer
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 accepted factory-tested transformer
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material_balance
  • Sources:
Amorphous magnetic-core strip (amorphous_alloy_strip)

Record amorphous alloy strip only for an amorphous-core design; do not also record grain-oriented electrical steel for the same core unless both are physically incorporated and separately documented.

  • Selected flow: Amorphous alloy strip db4d6a66-a479-428f-b005-f5efbee3106d
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg; unit group 93a60a57-a4c8-11da-a746-0800200c9a66
  • Amount rule: Product-specific issued mass less traceable unused returns, normalized to one accepted transformer
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 accepted factory-tested transformer
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material_balance
  • Sources:
Copper winding conductor (copper_wire)

Record copper wire when copper conductor is incorporated in transformer windings. Do not use this row for aluminum conductor or for mixed conductor stock.

  • Selected flow: copper wire da2d966d-fe62-44dc-ba0f-b1cd7c7cf33e
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg; unit group 93a60a57-a4c8-11da-a746-0800200c9a66
  • Amount rule: Product-specific issued copper-wire mass less traceable unused returns, normalized to one accepted transformer
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 accepted factory-tested transformer
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material_balance
  • Sources:
Aluminum winding conductor (aluminum_wire)

Record aluminum wire only when aluminum conductor is incorporated in transformer windings. Do not substitute unwrought aluminum or a conductor of unspecified metal.

  • Selected flow: Aluminum wire 89db8507-09bd-45f8-ba96-4e459058412c
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg; unit group 93a60a57-a4c8-11da-a746-0800200c9a66
  • Amount rule: Product-specific issued aluminum-wire mass less traceable unused returns, normalized to one accepted transformer
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 accepted factory-tested transformer
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material_balance
  • Sources:
Epoxy resin for a cast-resin insulation system (epoxy_resin)

Record formulated epoxy resin only when it is consumed in a cast-resin or resin-encapsulated transformer insulation system. Other distinct resin, hardener, filler, or solvent inputs must be added as separate atomic rows.

  • Selected flow: Epoxy resin
  • Flow property / unit: Mass / kg
  • Amount rule: Product-specific net resin mass issued to casting and curing, normalized to one accepted transformer
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 accepted factory-tested transformer
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material_balance
  • Sources:
Electrical insulation paper (electrical_insulation_paper)

Record electrical insulation paper when incorporated between turns, layers, windings, or core-and-coil components. Distinct pressboard or other insulation products must be added separately when used.

  • Selected flow: Electrical insulation paper
  • Flow property / unit: Mass / kg
  • Amount rule: Product-specific issued insulation-paper mass less traceable unused returns, normalized to one accepted transformer
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 accepted factory-tested transformer
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material_balance
  • Sources:
Transformer insulating oil (transformer_insulating_oil)

Record transformer insulating oil only for a liquid-filled design and include both the oil retained in the accepted product and documented manufacturing losses crossing the site boundary.

  • Selected flow: Transformer insulating oil 252efad6-76d5-55f4-a338-0ed8d03cf335
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg; unit group 93a60a57-a4c8-11da-a746-0800200c9a66
  • Amount rule: Product-specific delivered or issued oil mass less traceable unused return and stock change, normalized to one accepted transformer
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 accepted factory-tested transformer
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material_balance
  • Sources:
Purchased transformer structural components and casing (transformer_structural_components)

Record the purchased transformer-specific structural subassembly when it crosses the foreground boundary as one supplied product. If the site fabricates individual tank or enclosure materials, replace this subassembly row with separate concrete input rows and avoid double counting.

  • Selected flow: Transformer structural components and casing d4d9d3f9-9a57-4ca3-953c-f9bad98d5bc1
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg; unit group 93a60a57-a4c8-11da-a746-0800200c9a66
  • Amount rule: Product-specific received subassembly mass incorporated in one accepted transformer
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 accepted factory-tested transformer
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material_balance
  • Sources:
Factory electricity (electricity)

Record electricity delivered to the declared manufacturing and factory-test meter boundary. Exclude electricity attributable to downstream transformer operation.

  • Selected flow: Electricity 890a70b7-b677-4e2a-8a1b-7d017e0a10ae
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200b9a66 / MJ; unit group 93a60a57-a3c8-11da-a746-0800200c9a66
  • Amount rule: Metered manufacturing and factory-test electricity allocated by traceable submeter or documented causal allocation, normalized to one accepted transformer
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 accepted factory-tested transformer
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_utility_records
  • Sources:
Gaseous natural gas for on-site thermal operations (natural_gas)

Record gaseous natural gas only when it is burned or otherwise consumed on site for drying, curing, heating, or another declared manufacturing operation. Do not include upstream gas combustion embedded in purchased electricity or materials.

  • Selected flow: natural gas in the gaseous state 4f19ca0e-7b3b-11dd-ad8b-0800200c9a66
  • Flow property / unit: Volume 93a60a56-a3c8-22da-a746-0800200c9a66 / m3; unit group 93a60a57-a3c8-12da-a746-0800200c9a66
  • Amount rule: Metered or invoiced site consumption for included manufacturing operations, normalized to one accepted transformer and reported at declared reference conditions
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 accepted factory-tested transformer
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_utility_records
  • Sources:
Industrial oxygen for on-site oxy-fuel cutting (industrial_oxygen)

Record industrial oxygen only when oxy-fuel cutting or another identified manufacturing operation consumes purchased oxygen within the site boundary.

  • Selected flow: Industrial oxygen bd4b0f96-2090-4806-a648-335ab20ff401
  • Flow property / unit: Volume 93a60a56-a3c8-22da-a746-0800200c9a66 / m3; unit group 93a60a57-a3c8-12da-a746-0800200c9a66
  • Amount rule: Metered or cylinder-delivery oxygen volume consumed by included operations, normalized to one accepted transformer at declared reference conditions
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 accepted factory-tested transformer
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_utility_records
  • Sources:
Process water for cleaning or testing (process_water)

Record process water only when water crosses the site boundary for transformer-part cleaning, leak testing, or another identified manufacturing operation. Cooling water must be represented by a distinct row if it crosses the boundary.

  • Selected flow: Process Water 94a04f7e-2d5c-41f0-b182-d54a3b373a02
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg; unit group 93a60a57-a4c8-11da-a746-0800200c9a66
  • Amount rule: Metered or batch-record process-water mass consumed by included operations, normalized to one accepted transformer
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 accepted factory-tested transformer
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_water_chemical_records
  • Sources:
Sodium hydroxide for alkaline cleaning (sodium_hydroxide)

Record sodium hydroxide only when an alkaline cleaning bath consumes it within the foreground boundary. Report dry NaOH-equivalent mass and separately disclose supplied solution concentration.

  • Selected flow: Sodium hydroxide e0abcced-0611-4c24-9290-5a2c5a0c4169
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg; unit group 93a60a57-a4c8-11da-a746-0800200c9a66
  • Amount rule: Dry NaOH-equivalent mass from product mass multiplied by documented concentration, normalized to one accepted transformer
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 accepted factory-tested transformer
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_water_chemical_records
  • Sources:
Waste flows
Elementary flows

Outputs

Product flows
Accepted finished transformer (transformer_product)

Record the accepted reference product after factory tests and any rework required for acceptance. Rejected units are not counted as reference output.

  • Selected flow: Transformer 734249ea-34e6-471b-a05a-f5b26b818167
  • Flow property / unit: Number of items 01846770-4cfe-4a25-8ad9-919d8d378345 / Item(s); unit group 5beb6eed-33a9-47b8-9ede-1dfe8f679159
  • Amount rule: One accepted factory-tested transformer
  • Value mode: Fixed value (fixed_value)
  • Specificity: Generic (generic)
  • Normalization basis: 1 accepted factory-tested transformer
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_product_acceptance
  • Sources:
Waste flows
Post-industrial steel scrap (post_industrial_steel_scrap)

Record ferrous offcuts and rejected steel parts leaving the site as post-industrial steel scrap. Do not combine copper, aluminum, oil, or mixed hazardous residues in this row.

  • Selected flow: Post-industrial steel scrap c143745d-be4f-4d8f-b403-2dcbfe685349
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg; unit group 93a60a57-a4c8-11da-a746-0800200c9a66
  • Amount rule: Weighed shipment mass plus documented stock change attributable to the accepted transformer
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 accepted factory-tested transformer
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_waste_records
  • Sources:
Copper winding scrap (copper_scrap)

Record copper offcuts and rejected copper winding material leaving the site as copper scrap. Keep contaminated or mixed metal waste separate.

  • Selected flow: Copper Scrap 4fbbb5f1-560a-4052-ba0c-652c5dfc282e
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg; unit group 93a60a57-a4c8-11da-a746-0800200c9a66
  • Amount rule: Weighed shipment mass plus documented stock change attributable to the accepted transformer
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 accepted factory-tested transformer
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_waste_records
  • Sources:
Aluminum winding scrap (aluminum_scrap)

Record aluminum offcuts and rejected aluminum winding material only when the aluminum-conductor route applies. Keep contaminated or mixed metal waste separate.

  • Selected flow: Aluminium Scrap 96c5f842-ea53-419b-b1cd-c02c479efb45
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg; unit group 93a60a57-a4c8-11da-a746-0800200c9a66
  • Amount rule: Weighed shipment mass plus documented stock change attributable to the accepted transformer
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 accepted factory-tested transformer
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_waste_records
  • Sources:
Waste transformer insulating oil (waste_transformer_insulating_oil)

Record off-spec, spilled, drained, or otherwise discarded mineral transformer insulating oil that leaves the site for treatment. Do not use generic lubricating-oil identities or combine aqueous cleaning waste with this row.

  • Selected flow: Waste transformer insulating oil
  • Flow property / unit: Mass / kg
  • Amount rule: Weighed or volume-to-mass-converted shipment quantity attributable to the accepted liquid-filled transformer, with density and reference conditions documented
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 accepted factory-tested transformer
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_waste_records
  • Sources:
Elementary flows
Direct fossil carbon dioxide from on-site natural-gas combustion (fossil_carbon_dioxide)

Record only direct fossil carbon dioxide crossing from the foreground site to air when on-site natural-gas combustion occurs. Upstream emissions from purchased electricity, fuels, or materials remain in their upstream datasets.

  • Selected flow: carbon dioxide (fossil) 08a91e70-3ddc-11dd-923d-0050c2490048
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg; unit group 93a60a57-a4c8-11da-a746-0800200c9a66
  • Amount rule: Directly measured site emission attributable to included natural-gas combustion and normalized to one accepted transformer; if calculated instead, add a reviewed calculation rule and factor source before use
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 accepted factory-tested transformer
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_direct_emissions
  • Sources:

7. Allocation and Co-product Handling

rule_idapplies_torulesource_ids
allocation_subdivision_firstshared manufacturing operationsAvoid allocation by product-specific bills of materials, batch records, test records, and submetered utilities; subdivide production cells or time periods whenever the records permit.
allocation_causal_shared_inputsresidual shared utilities and consumablesWhen subdivision is not possible, use a documented causal driver such as machine time, oven occupancy, test duration, or measured throughput that reflects consumption; disclose the driver and test sensitivity to a reasonable alternative.
allocation_scrap_no_creditscrap and waste outputsReport scrap and waste as physical outputs at the factory gate. Do not subtract avoided virgin-material burdens or recycling credits from the foreground manufacturing inventory; downstream models may apply a separately disclosed end-of-life allocation convention.
allocation_rework_and_rejectsrework and rejected unitsAttribute rework inputs and the material and energy burden of rejected units to accepted output using the same production-period records; do not count a rejected transformer as reference output.

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_material_balancetransformer_manufacturingmaterial and purchased-subassembly inputspurchase, warehouse issue, return, stock and bill-of-material recordsmaterial identity; supplier; lot; received mass; issued mass; unused return; opening and closing stock; product serial or batch; route applicabilityReconcile purchasing and stores records to the product-specific bill of materials and production orderkgEach receipt and production orderRepresentative continuous production period, normally at least 12 months unless justifiedAll included manufacturing buildings and stores at the declared siteNet input equals receipts plus opening stock minus returns, closing stock and documented transfers; normalize to accepted unitsCalibrated scale records; invoices; material certificates; stock reconciliation; bill-of-material revision
cp_utility_recordstransformer_manufacturingelectricity, natural gas and industrial oxygen inputsmeter, invoice and cylinder-delivery recordsmeter id; opening and closing readings; energy or gas quantity; reference conditions; delivery quantity; process area; production period; allocation driverPrefer process or production-area submeters; reconcile to site invoices and delivery recordsMJ for electricity; m3 for gasesMeter interval or each delivery, aggregated monthlySame production period as accepted product outputAll included production and factory-test metersSubtract excluded loads, apply documented causal allocation, and divide by accepted transformer countMeter calibration; invoice reconciliation; meter map; excluded-load log
cp_water_chemical_recordstransformer_manufacturingprocess water and sodium hydroxide inputswater-meter, batch make-up and chemical issue recordswater volume or mass; chemical product mass; NaOH concentration; bath make-up; bath disposal; production order; density conversionRead meters and cleaning-bath records; calculate dry NaOH-equivalent from supplied product mass and concentrationkgEach batch or meter interval, aggregated monthlySame production period as accepted product outputIncluded cleaning and testing operationsSum net input, document reuse and stock change, and normalize to accepted transformer countMeter calibration; concentration certificate; batch sheet; stock reconciliation
cp_product_acceptancetransformer_manufacturingaccepted transformer outputproduction order and factory acceptance test recordserial number; product model; acceptance status; rated power; voltages; frequency; phases; losses; impedance; insulation and cooling system; total mass; accessoriesCount only units with completed acceptance records and link each unit to its product configurationItem(s) and kgEach unitSame production period as inventory recordsDeclared factory and test bayCount accepted units and retain product-level qualifiers; normalize inventory to one accepted unitSigned acceptance record; calibrated test equipment; weigh record; configuration release
cp_waste_recordstransformer_manufacturingsteel, copper, aluminum and waste insulating-oil outputswaste container, scale, shipment, stock and treatment recordswaste identity; source operation; container; gross and tare mass; stock change; shipment date; destination; treatment routeWeigh each shipment or container and reconcile opening and closing waste stockkgEach container or shipment, aggregated monthlySame production period as accepted product outputAll included production and waste-storage areasNet waste equals shipments plus closing stock minus opening stock and documented incoming transfers; allocate by source records and normalize to accepted unitsScale calibration; waste manifest; carrier receipt; stock reconciliation; photographs or contamination classification
cp_direct_emissionstransformer_manufacturingdirect fossil carbon dioxide outputstack or exhaust measurement recordsource id; fuel-consuming operation; concentration; flow rate; sampling duration; operating hours; fossil attribution; production periodUse calibrated direct measurement covering included on-site combustion; calculated values require a separately reviewed rule and factor sourcekgEach test or continuous interval according to monitoring systemRepresentative operating period aligned with productionEvery included combustion sourceIntegrate measured mass over operating time, apply documented production allocation, and normalize to accepted unitsCalibration; sampling report; operating log; source inventory; fossil-origin evidence

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
calc_normalize_per_transformerall foreground exchangesNormalized amount equals the net exchange assigned to the product configuration divided by the count of accepted transformers represented by the records.net exchange; accepted transformer countexchange per 1 accepted transformer
calc_electricity_conversionelectricity reported in kWhElectrical energy in MJ equals metered kWh multiplied by 3.6; retain the original meter value and conversion.metered kWhelectricity MJ
calc_naoh_dry_equivalentsodium hydroxide solutionDry NaOH-equivalent mass equals supplied solution mass multiplied by the supplier-certified NaOH mass fraction.solution mass; certified NaOH mass fractionkg dry NaOH equivalent
calc_inventory_reconciliationeach material familyNet material input must reconcile to incorporated product mass plus same-material waste, documented other loss, and stock change; investigate and disclose any residual rather than assigning it to an umbrella flow.net input; incorporated mass; waste mass; other loss; stock changematerial-specific reconciliation residual

Data Quality Requirements

requirement_idApplies toRequirementEvidence
dq_product_identityreference productLink every accepted item to a serial number or production order and retain all required reference-flow qualifiers.Product configuration, nameplate data, acceptance record and bill-of-material revision
dq_temporal_alignmentall foreground recordsUse one representative production period across inputs, outputs and accepted units; disclose shutdowns, commissioning, unusual rework and any shorter-than-12-month period.Dated meter, purchasing, stock, production, test and waste records
dq_completenesssite boundaryReconcile purchasing, utility, output and waste totals; disclose missing meters, estimates, excluded buildings and every actual atomic flow added beyond the minimum rows.Site flow map, reconciliation worksheet and signed completeness review
dq_variant_consistencyconditional routesApply mutually exclusive or combined core, conductor and insulation rows according to the actual bill of materials; do not infer route from the category name.Bill of materials, drawings, material certificates and production traveller
dq_source_representativenessupstream datasetsSelect upstream datasets matching material grade, product state, supplier technology, geography and period where possible; disclose proxies and sensitivity.Supplier declarations, dataset metadata and proxy log
dq_performance_metadatadownstream interpretationRetain rated power, voltage ratio, frequency, phase count, no-load and load losses, test conditions, impedance, cooling and insulation system, reference service life and loading profile because factory-gate mass alone does not describe transformer function.Nameplate, type or routine test report, technical specification and declared use scenario

9. Validation Rules

rule_idapplies_torulesource_ids
validation_reference_flowreference productFail validation unless the output is exactly one accepted Transformer item with the listed product, property and unit-group UUIDs and every required qualifier is populated.eu-power-transformers-regulation-548-2014
validation_inventory_identityinventory rowsFail validation when a selected flow combines multiple materials, utilities, wastes, or emissions, when an unresolved row is assigned a proxy UUID, or when a conditional row lacks route applicability.
validation_mass_reconciliationmaterial familiesRequire a documented material-specific reconciliation and investigate non-zero residuals; do not balance one material with another or silently assign a residual to other waste.
validation_boundary_separationmanufacturing energy and emissionsFail validation if use-phase transformer losses or upstream emissions from purchased electricity, fuels, or materials are counted as direct factory exchanges.ec-transformer-impact-assessment-2014
validation_bilingual_identitylocalized flow displaysRequire identical row ids, UUIDs and controlled values across languages and require the exact Tiangong Chinese baseName for every UUID-bearing flow.
validation_unresolved_evidencepublication readinessTreat the four unresolved flow UUIDs and every unresolved external range-evidence need as review blockers for publication, while retaining foreground collection requirements for candidate use.

10. Published Dataset Profile

FieldValue
dataset_roleProduct-specific factory-gate foreground manufacturing dataset for one accepted electrical transformer
downstream_usesecondary_dataset; background_dataset
allowed_useSupplier-specific or representative transformer manufacturing in product systems when the declared design, rating, technology, geography, period and factory-gate boundary match; linkage to separately modelled transport, installation, use, maintenance and end-of-life stages
excluded_useDirect comparison of transformer efficiency, lifetime performance or whole-life impacts without compatible rated power, voltage, loss, loading, service-life and downstream scenarios; representation of static converters, inductors, parts, substations or contract manufacturing services
required_metadataCanonical PCR id; product and UUID identity; all required reference-flow qualifiers; site and production period; bill-of-material revision; route applicability; collection protocols; allocation drivers; accepted-unit count; total mass; upstream dataset choices; exclusions and unresolved evidence
required_quality_disclosureTemporal and site coverage; meter and scale calibration; record completeness; material reconciliation residuals; data gaps and estimates; proxy upstream datasets; conditional rows; stock changes; scrap destinations; direct-emission measurement coverage; uncertainty and review status
update_triggerChange in transformer design, rated power family, core or conductor technology, insulation or cooling system, factory or production line, bill of materials, energy supply, cleaning or finishing route, allocation driver, upstream dataset, applicable performance specification, or evidence that materially changes the normalized inventory

11. Data Sources

Source idTypeReferenceUsed for
un-cpc-3-0-structure-2025Dataset (dataset)United Nations Statistics Division, CPC Version 3.0 Structure, 30 June 2025, https://unstats.un.org/unsd/classifications/Econ/Download/In%20Text/CPC_Ver_3.0_Structure_30Jun2025.csv, retrieved 2026-09-04Official CPC 46121 product classification identity and exclusions of neighbouring CPC products
eu-power-transformers-regulation-548-2014Standard (standard)Commission Regulation (EU) No 548/2014 of 21 May 2014 with regard to small, medium and large power transformers, https://eur-lex.europa.eu/legal-content/EN/TXT/PDF/?uri=CELEX%3A32014R0548, retrieved 2026-09-04Power-transformer definition; rated power, voltage, frequency, liquid-immersed and dry-type qualifiers; performance disclosure context
ec-transformer-impact-assessment-2014Official guidance (official_guidance)European Commission, Commission Staff Working Document Impact Assessment accompanying power-transformer ecodesign requirements, SWD(2014) 162, https://ec.europa.eu/smart-regulation/impact/ia_carried_out/docs/ia_2014/swd_2014_0162_en.pdf, retrieved 2026-09-04Transformer variant and lifecycle context; magnetic steel, copper or aluminum, resin and oil relevance; factory loss testing and downstream-stage separation
gbt-1094-1-2013Standard (standard)State Administration for Market Regulation and Standardization Administration of China, GB/T 1094.1-2013 Power transformers—Part 1: General, https://openstd.samr.gov.cn/bzgk/std/newGbInfo?hcno=C3539A02733314553221D30BB7A2A0DF, retrieved 2026-09-04Professional Chinese product title 电力变压器 and terminology alignment

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 3
Rule IDApplies toRuleSource IDs
boundary_factory_gateforeground manufacturingInclude material preparation, core and winding manufacture, insulation and structural assembly, applicable drying or casting or liquid filling, cleaning and finishing, final assembly, and factory testing through acceptance of the finished transformer at the factory gate.ec-transformer-impact-assessment-2014
boundary_variant_disclosureproduct and route selectionDistinguish liquid-immersed and dry-type insulation systems and conventional electrical-steel and amorphous-core routes; include each conditional atomic exchange only when the declared product and site records demonstrate that route.eu-power-transformers-regulation-548-2014, ec-transformer-impact-assessment-2014
boundary_downstream_exclusiondownstream lifecycle stagesExclude outbound transport, installation, use-phase electricity losses, maintenance, refurbishment, and end-of-life from this factory-gate foreground inventory; model them as separate downstream processes when the study goal requires them.ec-transformer-impact-assessment-2014
Allocation rules · 4
Rule IDApplies toRuleSource IDs
allocation_subdivision_firstshared manufacturing operationsAvoid allocation by product-specific bills of materials, batch records, test records, and submetered utilities; subdivide production cells or time periods whenever the records permit.
allocation_causal_shared_inputsresidual shared utilities and consumablesWhen subdivision is not possible, use a documented causal driver such as machine time, oven occupancy, test duration, or measured throughput that reflects consumption; disclose the driver and test sensitivity to a reasonable alternative.
allocation_scrap_no_creditscrap and waste outputsReport scrap and waste as physical outputs at the factory gate. Do not subtract avoided virgin-material burdens or recycling credits from the foreground manufacturing inventory; downstream models may apply a separately disclosed end-of-life allocation convention.
allocation_rework_and_rejectsrework and rejected unitsAttribute rework inputs and the material and energy burden of rejected units to accepted output using the same production-period records; do not count a rejected transformer as reference output.
Validation rules · 6
Rule IDApplies toRuleSource IDs
validation_reference_flowreference productFail validation unless the output is exactly one accepted Transformer item with the listed product, property and unit-group UUIDs and every required qualifier is populated.eu-power-transformers-regulation-548-2014
validation_inventory_identityinventory rowsFail validation when a selected flow combines multiple materials, utilities, wastes, or emissions, when an unresolved row is assigned a proxy UUID, or when a conditional row lacks route applicability.
validation_mass_reconciliationmaterial familiesRequire a documented material-specific reconciliation and investigate non-zero residuals; do not balance one material with another or silently assign a residual to other waste.
validation_boundary_separationmanufacturing energy and emissionsFail validation if use-phase transformer losses or upstream emissions from purchased electricity, fuels, or materials are counted as direct factory exchanges.ec-transformer-impact-assessment-2014
validation_bilingual_identitylocalized flow displaysRequire identical row ids, UUIDs and controlled values across languages and require the exact Tiangong Chinese baseName for every UUID-bearing flow.
validation_unresolved_evidencepublication readinessTreat the four unresolved flow UUIDs and every unresolved external range-evidence need as review blockers for publication, while retaining foreground collection requirements for candidate use.
Processes and inputs/outputs · 1
Process IDProcess nameInput flowsOutput flows
transformer_manufacturingElectrical-transformer manufacturing and factory testing136

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page

1. Scope and Applicability2. Product Category Identity3. Reference Flow4. Measurement and Unit Rules5. System BoundaryBoundary Abstraction6. Process Inventory StructureProcess MapProcess: Electrical-transformer manufacturing and factory testing (transformer_manufacturing)InputsProduct flowsGrain-oriented electrical steel for a conventional magnetic core (grain_oriented_electrical_steel)Amorphous magnetic-core strip (amorphous_alloy_strip)Copper winding conductor (copper_wire)Aluminum winding conductor (aluminum_wire)Epoxy resin for a cast-resin insulation system (epoxy_resin)Electrical insulation paper (electrical_insulation_paper)Transformer insulating oil (transformer_insulating_oil)Purchased transformer structural components and casing (transformer_structural_components)Factory electricity (electricity)Gaseous natural gas for on-site thermal operations (natural_gas)Industrial oxygen for on-site oxy-fuel cutting (industrial_oxygen)Process water for cleaning or testing (process_water)Sodium hydroxide for alkaline cleaning (sodium_hydroxide)Waste flowsElementary flowsOutputsProduct flowsAccepted finished transformer (transformer_product)Waste flowsPost-industrial steel scrap (post_industrial_steel_scrap)Copper winding scrap (copper_scrap)Aluminum winding scrap (aluminum_scrap)Waste transformer insulating oil (waste_transformer_insulating_oil)Elementary flowsDirect fossil carbon dioxide from on-site natural-gas combustion (fossil_carbon_dioxide)7. Allocation and Co-product Handling8. Foreground Data Collection, Calculation, and Quality RulesData Collection ProtocolsCalculation RulesData Quality Requirements9. Validation Rules10. Published Dataset Profile11. Data Sources