Other prepared or preserved meat, meat offal or blood · Process: Sanitation and conditional on-site wastewater treatment (sanitation_wastewater)
Other prepared or preserved meat, meat offal or blood · Process: Sanitation and conditional on-site wastewater treatment (sanitation_wastewater): This process uses…
- Lifecycle status
- Candidate
- Content maturity
- Authored methodology
- Current version
- No published version
- Readiness
- Review required
- Last updated
Methodology and translation states come from the source record; publishing this website does not change their review status.
Content languages
Status, classification and source details
Readiness
- Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.
Classification mapping
Source
Process: Sanitation and conditional on-site wastewater treatment (sanitation_wastewater)
This process uses Sanitation records allocated to the same production lot as its quantitative reference. Apply only its concrete cards that match the locked bill of materials, package, equipment, destination, and route; absence must be demonstrated from records rather than replaced by a pooled exchange.
Inputs
Product flows
Grid electricity input (sanitation_wastewater_grid_electricity)
Grid electricity is an individual purchased resource for this process. It remains a distinct card even when a shared meter requires a documented allocation.
- Selected flow: Grid electricity
- Flow property / unit: Energy / kWh
- Amount rule: Record the separately metered or invoiced grid electricity used by this process; do not combine it with another energy carrier.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_resource - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Purchased steam input (sanitation_wastewater_purchased_steam)
Purchased steam is an individual purchased resource for this process. It remains a distinct card even when a shared meter requires a documented allocation.
- Selected flow: Purchased steam
- Flow property / unit: Energy / MJ
- Amount rule: Record the separately metered or invoiced purchased steam used by this process; do not combine it with another energy carrier.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_resource - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Purchased hot water input (sanitation_wastewater_purchased_hot_water)
Purchased hot water is an individual purchased resource for this process. It remains a distinct card even when a shared meter requires a documented allocation.
- Selected flow: Purchased hot water
- Flow property / unit: Energy / MJ
- Amount rule: Record the separately metered or invoiced purchased hot water used by this process; do not combine it with another energy carrier.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_resource - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Natural gas input (sanitation_wastewater_natural_gas)
Natural gas is an individual purchased resource for this process. It remains a distinct card even when a shared meter requires a documented allocation.
- Selected flow: Natural gas
- Flow property / unit: Energy / MJ
- Amount rule: Record the separately metered or invoiced natural gas used by this process; do not combine it with another energy carrier.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_resource - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Diesel input (sanitation_wastewater_diesel)
Diesel is an individual purchased resource for this process. It remains a distinct card even when a shared meter requires a documented allocation.
- Selected flow: Diesel
- Flow property / unit: Energy / MJ
- Amount rule: Record the separately metered or invoiced diesel used by this process; do not combine it with another energy carrier.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_resource - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Liquefied petroleum gas input (sanitation_wastewater_liquefied_petroleum_gas)
Liquefied petroleum gas is an individual purchased resource for this process. It remains a distinct card even when a shared meter requires a documented allocation.
- Selected flow: Liquefied petroleum gas
- Flow property / unit: Energy / MJ
- Amount rule: Record the separately metered or invoiced liquefied petroleum gas used by this process; do not combine it with another energy carrier.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_resource - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Purchased compressed air input (sanitation_wastewater_purchased_compressed_air)
Purchased compressed air is an individual purchased resource for this process. It remains a distinct card even when a shared meter requires a documented allocation.
- Selected flow: Purchased compressed air
- Flow property / unit: Volume / m3
- Amount rule: Record the separately metered or invoiced purchased compressed air used by this process; do not combine it with another energy carrier.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_resource - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Potable mains water input (sanitation_wastewater_potable_mains_water)
Potable mains water is one distinct water-source exchange for this process and is not pooled with another water source.
- Selected flow: Potable mains water
- Flow property / unit: Mass / kg
- Amount rule: Record potable mains water withdrawn or supplied to this process from a calibrated meter; keep this source separate from the other water sources.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_resource - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
sodium hydroxide input (sanitation_wastewater_sodium_hydroxide)
Sodium hydroxide is one exact cleaning, disinfection, or wastewater-treatment chemical applicable only when actually dosed.
- Selected flow: Sodium hydroxide
- Flow property / unit: Mass / kg
- Amount rule: Record the actual sodium hydroxide issue mass from concentration-specific purchase and dosing records; do not combine it with another cleaning, disinfection, or treatment chemical.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_material - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
nitric acid input (sanitation_wastewater_nitric_acid)
Nitric acid is one exact cleaning, disinfection, or wastewater-treatment chemical applicable only when actually dosed.
- Selected flow: Nitric acid
- Flow property / unit: Mass / kg
- Amount rule: Record the actual nitric acid issue mass from concentration-specific purchase and dosing records; do not combine it with another cleaning, disinfection, or treatment chemical.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_material - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
phosphoric acid input (sanitation_wastewater_phosphoric_acid)
Phosphoric acid is one exact cleaning, disinfection, or wastewater-treatment chemical applicable only when actually dosed.
- Selected flow: Phosphoric acid
- Flow property / unit: Mass / kg
- Amount rule: Record the actual phosphoric acid issue mass from concentration-specific purchase and dosing records; do not combine it with another cleaning, disinfection, or treatment chemical.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_material - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
sodium hypochlorite input (sanitation_wastewater_sodium_hypochlorite)
Sodium hypochlorite is one exact cleaning, disinfection, or wastewater-treatment chemical applicable only when actually dosed.
- Selected flow: Sodium hypochlorite
- Flow property / unit: Mass / kg
- Amount rule: Record the actual sodium hypochlorite issue mass from concentration-specific purchase and dosing records; do not combine it with another cleaning, disinfection, or treatment chemical.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_material - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
peracetic acid input (sanitation_wastewater_peracetic_acid)
Peracetic acid is one exact cleaning, disinfection, or wastewater-treatment chemical applicable only when actually dosed.
- Selected flow: Peracetic acid
- Flow property / unit: Mass / kg
- Amount rule: Record the actual peracetic acid issue mass from concentration-specific purchase and dosing records; do not combine it with another cleaning, disinfection, or treatment chemical.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_material - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
hydrogen peroxide input (sanitation_wastewater_hydrogen_peroxide)
Hydrogen peroxide is one exact cleaning, disinfection, or wastewater-treatment chemical applicable only when actually dosed.
- Selected flow: Hydrogen peroxide
- Flow property / unit: Mass / kg
- Amount rule: Record the actual hydrogen peroxide issue mass from concentration-specific purchase and dosing records; do not combine it with another cleaning, disinfection, or treatment chemical.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_material - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
benzalkonium chloride input (sanitation_wastewater_benzalkonium_chloride)
Benzalkonium chloride is one exact cleaning, disinfection, or wastewater-treatment chemical applicable only when actually dosed.
- Selected flow: Benzalkonium chloride
- Flow property / unit: Mass / kg
- Amount rule: Record the actual benzalkonium chloride issue mass from concentration-specific purchase and dosing records; do not combine it with another cleaning, disinfection, or treatment chemical.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_material - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
ethanol input (sanitation_wastewater_ethanol)
Ethanol is one exact cleaning, disinfection, or wastewater-treatment chemical applicable only when actually dosed.
- Selected flow: Ethanol
- Flow property / unit: Mass / kg
- Amount rule: Record the actual ethanol issue mass from concentration-specific purchase and dosing records; do not combine it with another cleaning, disinfection, or treatment chemical.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_material - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
ferric chloride input (sanitation_wastewater_ferric_chloride)
Ferric chloride is one exact cleaning, disinfection, or wastewater-treatment chemical applicable only when actually dosed.
- Selected flow: Ferric chloride
- Flow property / unit: Mass / kg
- Amount rule: Record the actual ferric chloride issue mass from concentration-specific purchase and dosing records; do not combine it with another cleaning, disinfection, or treatment chemical.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_material - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
aluminium sulfate input (sanitation_wastewater_aluminium_sulfate)
Aluminium sulfate is one exact cleaning, disinfection, or wastewater-treatment chemical applicable only when actually dosed.
- Selected flow: Aluminium sulfate
- Flow property / unit: Mass / kg
- Amount rule: Record the actual aluminium sulfate issue mass from concentration-specific purchase and dosing records; do not combine it with another cleaning, disinfection, or treatment chemical.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_material - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
calcium hydroxide input (sanitation_wastewater_calcium_hydroxide)
Calcium hydroxide is one exact cleaning, disinfection, or wastewater-treatment chemical applicable only when actually dosed.
- Selected flow: Calcium hydroxide
- Flow property / unit: Mass / kg
- Amount rule: Record the actual calcium hydroxide issue mass from concentration-specific purchase and dosing records; do not combine it with another cleaning, disinfection, or treatment chemical.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_material - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
anionic polyacrylamide input (sanitation_wastewater_anionic_polyacrylamide)
Anionic polyacrylamide is one exact cleaning, disinfection, or wastewater-treatment chemical applicable only when actually dosed.
- Selected flow: Anionic polyacrylamide
- Flow property / unit: Mass / kg
- Amount rule: Record the actual anionic polyacrylamide issue mass from concentration-specific purchase and dosing records; do not combine it with another cleaning, disinfection, or treatment chemical.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_material - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Waste flows
raw-material thawing wastewater treatment input (sanitation_wastewater_input_raw_material_receipt_raw_material_thawing_wastewater)
Raw-material thawing wastewater is one traceable point-of-generation waste input to conditional on-site treatment.
- Selected flow: Raw-material thawing wastewater
- Flow property / unit: Mass / kg
- Amount rule: Record only the mass transferred to on-site treatment from the matching point-of-generation record; omit this treatment input when sent directly to external management.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
raw-material drip-loss wastewater treatment input (sanitation_wastewater_input_raw_material_receipt_raw_material_drip_loss_wastewater)
Raw-material drip-loss wastewater is one traceable point-of-generation waste input to conditional on-site treatment.
- Selected flow: Raw-material drip-loss wastewater
- Flow property / unit: Mass / kg
- Amount rule: Record only the mass transferred to on-site treatment from the matching point-of-generation record; omit this treatment input when sent directly to external management.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
cutting-equipment wash wastewater treatment input (sanitation_wastewater_input_preparation_formulation_cutting_equipment_wash_wastewater)
Cutting-equipment wash wastewater is one traceable point-of-generation waste input to conditional on-site treatment.
- Selected flow: Cutting-equipment wash wastewater
- Flow property / unit: Mass / kg
- Amount rule: Record only the mass transferred to on-site treatment from the matching point-of-generation record; omit this treatment input when sent directly to external management.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
mincing-equipment wash wastewater treatment input (sanitation_wastewater_input_preparation_formulation_mincing_equipment_wash_wastewater)
Mincing-equipment wash wastewater is one traceable point-of-generation waste input to conditional on-site treatment.
- Selected flow: Mincing-equipment wash wastewater
- Flow property / unit: Mass / kg
- Amount rule: Record only the mass transferred to on-site treatment from the matching point-of-generation record; omit this treatment input when sent directly to external management.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
formulation-equipment wash wastewater treatment input (sanitation_wastewater_input_preparation_formulation_formulation_equipment_wash_wastewater)
Formulation-equipment wash wastewater is one traceable point-of-generation waste input to conditional on-site treatment.
- Selected flow: Formulation-equipment wash wastewater
- Flow property / unit: Mass / kg
- Amount rule: Record only the mass transferred to on-site treatment from the matching point-of-generation record; omit this treatment input when sent directly to external management.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
spent beef cooking liquor treatment input (sanitation_wastewater_input_thermal_preservation_spent_beef_cooking_liquor)
Spent beef cooking liquor is one traceable point-of-generation waste input to conditional on-site treatment.
- Selected flow: Spent beef cooking liquor
- Flow property / unit: Mass / kg
- Amount rule: Record only the mass transferred to on-site treatment from the matching point-of-generation record; omit this treatment input when sent directly to external management.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
spent pork-liver cooking liquor treatment input (sanitation_wastewater_input_thermal_preservation_spent_pork_liver_cooking_liquor)
Spent pork-liver cooking liquor is one traceable point-of-generation waste input to conditional on-site treatment.
- Selected flow: Spent pork-liver cooking liquor
- Flow property / unit: Mass / kg
- Amount rule: Record only the mass transferred to on-site treatment from the matching point-of-generation record; omit this treatment input when sent directly to external management.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
spent chicken cooking liquor treatment input (sanitation_wastewater_input_thermal_preservation_spent_chicken_cooking_liquor)
Spent chicken cooking liquor is one traceable point-of-generation waste input to conditional on-site treatment.
- Selected flow: Spent chicken cooking liquor
- Flow property / unit: Mass / kg
- Amount rule: Record only the mass transferred to on-site treatment from the matching point-of-generation record; omit this treatment input when sent directly to external management.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
cooking-kettle wastewater treatment input (sanitation_wastewater_input_thermal_preservation_cooking_kettle_wastewater)
Cooking-kettle wastewater is one traceable point-of-generation waste input to conditional on-site treatment.
- Selected flow: Cooking-kettle wastewater
- Flow property / unit: Mass / kg
- Amount rule: Record only the mass transferred to on-site treatment from the matching point-of-generation record; omit this treatment input when sent directly to external management.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
fryer-cleaning wastewater treatment input (sanitation_wastewater_input_thermal_preservation_fryer_cleaning_wastewater)
Fryer-cleaning wastewater is one traceable point-of-generation waste input to conditional on-site treatment.
- Selected flow: Fryer-cleaning wastewater
- Flow property / unit: Mass / kg
- Amount rule: Record only the mass transferred to on-site treatment from the matching point-of-generation record; omit this treatment input when sent directly to external management.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
roasting-oven wash wastewater treatment input (sanitation_wastewater_input_thermal_preservation_roasting_oven_wash_wastewater)
Roasting-oven wash wastewater is one traceable point-of-generation waste input to conditional on-site treatment.
- Selected flow: Roasting-oven wash wastewater
- Flow property / unit: Mass / kg
- Amount rule: Record only the mass transferred to on-site treatment from the matching point-of-generation record; omit this treatment input when sent directly to external management.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
steam-cooker condensate wastewater treatment input (sanitation_wastewater_input_thermal_preservation_steam_cooker_condensate_wastewater)
Steam-cooker condensate wastewater is one traceable point-of-generation waste input to conditional on-site treatment.
- Selected flow: Steam-cooker condensate wastewater
- Flow property / unit: Mass / kg
- Amount rule: Record only the mass transferred to on-site treatment from the matching point-of-generation record; omit this treatment input when sent directly to external management.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
container-rinse wastewater treatment input (sanitation_wastewater_input_hermetic_canning_container_rinse_wastewater)
Container-rinse wastewater is one traceable point-of-generation waste input to conditional on-site treatment.
- Selected flow: Container-rinse wastewater
- Flow property / unit: Mass / kg
- Amount rule: Record only the mass transferred to on-site treatment from the matching point-of-generation record; omit this treatment input when sent directly to external management.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
retort-cooling wastewater treatment input (sanitation_wastewater_input_hermetic_canning_retort_cooling_wastewater)
Retort-cooling wastewater is one traceable point-of-generation waste input to conditional on-site treatment.
- Selected flow: Retort-cooling wastewater
- Flow property / unit: Mass / kg
- Amount rule: Record only the mass transferred to on-site treatment from the matching point-of-generation record; omit this treatment input when sent directly to external management.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
spent vinegar liquor treatment input (sanitation_wastewater_input_pickling_seasoning_spent_vinegar_liquor)
Spent vinegar liquor is one traceable point-of-generation waste input to conditional on-site treatment.
- Selected flow: Spent vinegar liquor
- Flow property / unit: Mass / kg
- Amount rule: Record only the mass transferred to on-site treatment from the matching point-of-generation record; omit this treatment input when sent directly to external management.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
pickling-vessel wash wastewater treatment input (sanitation_wastewater_input_pickling_seasoning_pickling_vessel_wash_wastewater)
Pickling-vessel wash wastewater is one traceable point-of-generation waste input to conditional on-site treatment.
- Selected flow: Pickling-vessel wash wastewater
- Flow property / unit: Mass / kg
- Amount rule: Record only the mass transferred to on-site treatment from the matching point-of-generation record; omit this treatment input when sent directly to external management.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
packaging-line wash wastewater treatment input (sanitation_wastewater_input_packaging_storage_release_packaging_line_wash_wastewater)
Packaging-line wash wastewater is one traceable point-of-generation waste input to conditional on-site treatment.
- Selected flow: Packaging-line wash wastewater
- Flow property / unit: Mass / kg
- Amount rule: Record only the mass transferred to on-site treatment from the matching point-of-generation record; omit this treatment input when sent directly to external management.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Elementary flows
Groundwater input (sanitation_wastewater_groundwater)
Groundwater is one distinct water-source exchange for this process and is not pooled with another water source.
- Selected flow: Groundwater
- Flow property / unit: Mass / kg
- Amount rule: Record groundwater withdrawn or supplied to this process from a calibrated meter; keep this source separate from the other water sources.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_resource - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Surface water input (sanitation_wastewater_surface_water)
Surface water is one distinct water-source exchange for this process and is not pooled with another water source.
- Selected flow: Surface water
- Flow property / unit: Mass / kg
- Amount rule: Record surface water withdrawn or supplied to this process from a calibrated meter; keep this source separate from the other water sources.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_resource - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Outputs
Product flows
No exchange is prescribed in this flow-type group for this process.
Waste flows
Spent sodium-hydroxide cleaning solution (sanitation_wastewater_spent_sodium_hydroxide_cleaning_solution)
Spent sodium-hydroxide cleaning solution is one active-chemical-specific sanitation waste stream.
- Selected flow: Spent sodium-hydroxide cleaning solution
- Flow property / unit: Mass / kg
- Amount rule: Record the separately measured spent solution mass and its on-site treatment or external management destination.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Spent nitric-acid cleaning solution (sanitation_wastewater_spent_nitric_acid_cleaning_solution)
Spent nitric-acid cleaning solution is one active-chemical-specific sanitation waste stream.
- Selected flow: Spent nitric-acid cleaning solution
- Flow property / unit: Mass / kg
- Amount rule: Record the separately measured spent solution mass and its on-site treatment or external management destination.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Spent phosphoric-acid cleaning solution (sanitation_wastewater_spent_phosphoric_acid_cleaning_solution)
Spent phosphoric-acid cleaning solution is one active-chemical-specific sanitation waste stream.
- Selected flow: Spent phosphoric-acid cleaning solution
- Flow property / unit: Mass / kg
- Amount rule: Record the separately measured spent solution mass and its on-site treatment or external management destination.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Spent sodium-hypochlorite sanitising solution (sanitation_wastewater_spent_sodium_hypochlorite_sanitising_solution)
Spent sodium-hypochlorite sanitising solution is one active-chemical-specific sanitation waste stream.
- Selected flow: Spent sodium-hypochlorite sanitising solution
- Flow property / unit: Mass / kg
- Amount rule: Record the separately measured spent solution mass and its on-site treatment or external management destination.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Spent peracetic-acid sanitising solution (sanitation_wastewater_spent_peracetic_acid_sanitising_solution)
Spent peracetic-acid sanitising solution is one active-chemical-specific sanitation waste stream.
- Selected flow: Spent peracetic-acid sanitising solution
- Flow property / unit: Mass / kg
- Amount rule: Record the separately measured spent solution mass and its on-site treatment or external management destination.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Spent hydrogen-peroxide sanitising solution (sanitation_wastewater_spent_hydrogen_peroxide_sanitising_solution)
Spent hydrogen-peroxide sanitising solution is one active-chemical-specific sanitation waste stream.
- Selected flow: Spent hydrogen-peroxide sanitising solution
- Flow property / unit: Mass / kg
- Amount rule: Record the separately measured spent solution mass and its on-site treatment or external management destination.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Spent benzalkonium-chloride sanitising solution (sanitation_wastewater_spent_benzalkonium_chloride_sanitising_solution)
Spent benzalkonium-chloride sanitising solution is one active-chemical-specific sanitation waste stream.
- Selected flow: Spent benzalkonium-chloride sanitising solution
- Flow property / unit: Mass / kg
- Amount rule: Record the separately measured spent solution mass and its on-site treatment or external management destination.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Spent ethanol sanitising solution (sanitation_wastewater_spent_ethanol_sanitising_solution)
Spent ethanol sanitising solution is one active-chemical-specific sanitation waste stream.
- Selected flow: Spent ethanol sanitising solution
- Flow property / unit: Mass / kg
- Amount rule: Record the separately measured spent solution mass and its on-site treatment or external management destination.
- Value mode: Foreground record (
foreground_record) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Treated prepared-meat effluent sent to sewer (sanitation_wastewater_treated_prepared_meat_effluent_sent_to_sewer)
Treated prepared-meat effluent sent to sewer is one named treatment-output waste stream and remains separate from every other residue.
- Selected flow: Treated prepared-meat effluent sent to sewer
- Flow property / unit: Mass / kg
- Amount rule: Record separately measured mass leaving the declared treatment operation and its documented destination; do not net it against removed pollutant load.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Wastewater inlet-screen residue (sanitation_wastewater_wastewater_inlet_screen_residue)
Wastewater inlet-screen residue is one named treatment-output waste stream and remains separate from every other residue.
- Selected flow: Wastewater inlet-screen residue
- Flow property / unit: Mass / kg
- Amount rule: Record separately measured mass leaving the declared treatment operation and its documented destination; do not net it against removed pollutant load.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Dissolved-air-flotation sludge (sanitation_wastewater_dissolved_air_flotation_sludge)
Dissolved-air-flotation sludge is one named treatment-output waste stream and remains separate from every other residue.
- Selected flow: Dissolved-air-flotation sludge
- Flow property / unit: Mass / kg
- Amount rule: Record separately measured mass leaving the declared treatment operation and its documented destination; do not net it against removed pollutant load.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Biological wastewater-treatment sludge (sanitation_wastewater_biological_wastewater_treatment_sludge)
Biological wastewater-treatment sludge is one named treatment-output waste stream and remains separate from every other residue.
- Selected flow: Biological wastewater-treatment sludge
- Flow property / unit: Mass / kg
- Amount rule: Record separately measured mass leaving the declared treatment operation and its documented destination; do not net it against removed pollutant load.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Wastewater-treatment spent activated carbon (sanitation_wastewater_wastewater_treatment_spent_activated_carbon)
Wastewater-treatment spent activated carbon is one named treatment-output waste stream and remains separate from every other residue.
- Selected flow: Wastewater-treatment spent activated carbon
- Flow property / unit: Mass / kg
- Amount rule: Record separately measured mass leaving the declared treatment operation and its documented destination; do not net it against removed pollutant load.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Discarded polymeric wastewater-treatment membrane (sanitation_wastewater_discarded_polymeric_wastewater_treatment_membrane)
Discarded polymeric wastewater-treatment membrane is one named treatment-output waste stream and remains separate from every other residue.
- Selected flow: Discarded polymeric wastewater-treatment membrane
- Flow property / unit: Mass / kg
- Amount rule: Record separately measured mass leaving the declared treatment operation and its documented destination; do not net it against removed pollutant load.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Wastewater-treatment grit (sanitation_wastewater_wastewater_treatment_grit)
Wastewater-treatment grit is one named treatment-output waste stream and remains separate from every other residue.
- Selected flow: Wastewater-treatment grit
- Flow property / unit: Mass / kg
- Amount rule: Record separately measured mass leaving the declared treatment operation and its documented destination; do not net it against removed pollutant load.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_sanitation_wastewater_residue - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Elementary flows
Carbon dioxide, fossil to air (sanitation_wastewater_carbon_dioxide_fossil_to_air)
Carbon dioxide, fossil to air is reported as one direct elementary exchange from on-site combustion assigned to this process.
- Selected flow: Carbon dioxide, fossil to air
- Flow property / unit: Mass / kg
- Amount rule: Calculate the mass of this single emitted substance from the separately metered fuel use and a documented facility-, equipment-, or supplier-specific factor; do not use an uncited PCR default.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,eu-pef-2021-2279
Nitrogen monoxide to air (sanitation_wastewater_nitrogen_monoxide_to_air)
Nitrogen monoxide to air is reported as one direct elementary exchange from on-site combustion assigned to this process.
- Selected flow: Nitrogen monoxide to air
- Flow property / unit: Mass / kg
- Amount rule: Calculate the mass of this single emitted substance from the separately metered fuel use and a documented facility-, equipment-, or supplier-specific factor; do not use an uncited PCR default.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,eu-pef-2021-2279
Nitrogen dioxide to air (sanitation_wastewater_nitrogen_dioxide_to_air)
Nitrogen dioxide to air is reported as one direct elementary exchange from on-site combustion assigned to this process.
- Selected flow: Nitrogen dioxide to air
- Flow property / unit: Mass / kg
- Amount rule: Calculate the mass of this single emitted substance from the separately metered fuel use and a documented facility-, equipment-, or supplier-specific factor; do not use an uncited PCR default.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,eu-pef-2021-2279
Sulfur dioxide to air (sanitation_wastewater_sulfur_dioxide_to_air)
Sulfur dioxide to air is reported as one direct elementary exchange from on-site combustion assigned to this process.
- Selected flow: Sulfur dioxide to air
- Flow property / unit: Mass / kg
- Amount rule: Calculate the mass of this single emitted substance from the separately metered fuel use and a documented facility-, equipment-, or supplier-specific factor; do not use an uncited PCR default.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,eu-pef-2021-2279
Particulate matter below 2.5 micrometres to air (sanitation_wastewater_particulate_matter_below_2_5_micrometres_to_air)
Particulate matter below 2.5 micrometres to air is reported as one direct elementary exchange from on-site combustion assigned to this process.
- Selected flow: Particulate matter below 2.5 micrometres to air
- Flow property / unit: Mass / kg
- Amount rule: Calculate the mass of this single emitted substance from the separately metered fuel use and a documented facility-, equipment-, or supplier-specific factor; do not use an uncited PCR default.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,eu-pef-2021-2279
Particulate matter from 2.5 to 10 micrometres to air (sanitation_wastewater_particulate_matter_from_2_5_to_10_micrometres_to_air)
Particulate matter from 2.5 to 10 micrometres to air is reported as one direct elementary exchange from on-site combustion assigned to this process.
- Selected flow: Particulate matter from 2.5 to 10 micrometres to air
- Flow property / unit: Mass / kg
- Amount rule: Calculate the mass of this single emitted substance from the separately metered fuel use and a documented facility-, equipment-, or supplier-specific factor; do not use an uncited PCR default.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,eu-pef-2021-2279
Chemical oxygen demand to freshwater (sanitation_wastewater_chemical_oxygen_demand_to_freshwater)
Chemical oxygen demand to freshwater is one separately quantified elementary exchange from a documented direct discharge. It is not reported when the effluent goes to sewer without a direct freshwater release.
- Selected flow: Chemical oxygen demand to freshwater
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single discharged substance or water quantity from matched effluent-flow and sampling records for the reporting period; use non-detect treatment and units stated by the laboratory, with no PCR default concentration.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Biochemical oxygen demand to freshwater (sanitation_wastewater_biochemical_oxygen_demand_to_freshwater)
Biochemical oxygen demand to freshwater is one separately quantified elementary exchange from a documented direct discharge. It is not reported when the effluent goes to sewer without a direct freshwater release.
- Selected flow: Biochemical oxygen demand to freshwater
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single discharged substance or water quantity from matched effluent-flow and sampling records for the reporting period; use non-detect treatment and units stated by the laboratory, with no PCR default concentration.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Suspended solids to freshwater (sanitation_wastewater_suspended_solids_to_freshwater)
Suspended solids to freshwater is one separately quantified elementary exchange from a documented direct discharge. It is not reported when the effluent goes to sewer without a direct freshwater release.
- Selected flow: Suspended solids to freshwater
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single discharged substance or water quantity from matched effluent-flow and sampling records for the reporting period; use non-detect treatment and units stated by the laboratory, with no PCR default concentration.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Ammonium to freshwater (sanitation_wastewater_ammonium_to_freshwater)
Ammonium to freshwater is one separately quantified elementary exchange from a documented direct discharge. It is not reported when the effluent goes to sewer without a direct freshwater release.
- Selected flow: Ammonium to freshwater
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single discharged substance or water quantity from matched effluent-flow and sampling records for the reporting period; use non-detect treatment and units stated by the laboratory, with no PCR default concentration.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Nitrate to freshwater (sanitation_wastewater_nitrate_to_freshwater)
Nitrate to freshwater is one separately quantified elementary exchange from a documented direct discharge. It is not reported when the effluent goes to sewer without a direct freshwater release.
- Selected flow: Nitrate to freshwater
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single discharged substance or water quantity from matched effluent-flow and sampling records for the reporting period; use non-detect treatment and units stated by the laboratory, with no PCR default concentration.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Nitrite to freshwater (sanitation_wastewater_nitrite_to_freshwater)
Nitrite to freshwater is one separately quantified elementary exchange from a documented direct discharge. It is not reported when the effluent goes to sewer without a direct freshwater release.
- Selected flow: Nitrite to freshwater
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single discharged substance or water quantity from matched effluent-flow and sampling records for the reporting period; use non-detect treatment and units stated by the laboratory, with no PCR default concentration.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Phosphate to freshwater (sanitation_wastewater_phosphate_to_freshwater)
Phosphate to freshwater is one separately quantified elementary exchange from a documented direct discharge. It is not reported when the effluent goes to sewer without a direct freshwater release.
- Selected flow: Phosphate to freshwater
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single discharged substance or water quantity from matched effluent-flow and sampling records for the reporting period; use non-detect treatment and units stated by the laboratory, with no PCR default concentration.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Chloride to freshwater (sanitation_wastewater_chloride_to_freshwater)
Chloride to freshwater is one separately quantified elementary exchange from a documented direct discharge. It is not reported when the effluent goes to sewer without a direct freshwater release.
- Selected flow: Chloride to freshwater
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single discharged substance or water quantity from matched effluent-flow and sampling records for the reporting period; use non-detect treatment and units stated by the laboratory, with no PCR default concentration.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Acetic acid to freshwater (sanitation_wastewater_acetic_acid_to_freshwater)
Acetic acid to freshwater is one separately quantified elementary exchange from a documented direct discharge. It is not reported when the effluent goes to sewer without a direct freshwater release.
- Selected flow: Acetic acid to freshwater
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single discharged substance or water quantity from matched effluent-flow and sampling records for the reporting period; use non-detect treatment and units stated by the laboratory, with no PCR default concentration.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Peracetic acid to freshwater (sanitation_wastewater_peracetic_acid_to_freshwater)
Peracetic acid to freshwater is one separately quantified elementary exchange from a documented direct discharge. It is not reported when the effluent goes to sewer without a direct freshwater release.
- Selected flow: Peracetic acid to freshwater
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single discharged substance or water quantity from matched effluent-flow and sampling records for the reporting period; use non-detect treatment and units stated by the laboratory, with no PCR default concentration.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Chlorine to freshwater (sanitation_wastewater_chlorine_to_freshwater)
Chlorine to freshwater is one separately quantified elementary exchange from a documented direct discharge. It is not reported when the effluent goes to sewer without a direct freshwater release.
- Selected flow: Chlorine to freshwater
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single discharged substance or water quantity from matched effluent-flow and sampling records for the reporting period; use non-detect treatment and units stated by the laboratory, with no PCR default concentration.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Beef tallow to freshwater (sanitation_wastewater_beef_tallow_to_freshwater)
Beef tallow to freshwater is one separately quantified elementary exchange from a documented direct discharge. It is not reported when the effluent goes to sewer without a direct freshwater release.
- Selected flow: Beef tallow to freshwater
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single discharged substance or water quantity from matched effluent-flow and sampling records for the reporting period; use non-detect treatment and units stated by the laboratory, with no PCR default concentration.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Pork lard to freshwater (sanitation_wastewater_pork_lard_to_freshwater)
Pork lard to freshwater is one separately quantified elementary exchange from a documented direct discharge. It is not reported when the effluent goes to sewer without a direct freshwater release.
- Selected flow: Pork lard to freshwater
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single discharged substance or water quantity from matched effluent-flow and sampling records for the reporting period; use non-detect treatment and units stated by the laboratory, with no PCR default concentration.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Mutton fat to freshwater (sanitation_wastewater_mutton_fat_to_freshwater)
Mutton fat to freshwater is one separately quantified elementary exchange from a documented direct discharge. It is not reported when the effluent goes to sewer without a direct freshwater release.
- Selected flow: Mutton fat to freshwater
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single discharged substance or water quantity from matched effluent-flow and sampling records for the reporting period; use non-detect treatment and units stated by the laboratory, with no PCR default concentration.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Rabbit fat to freshwater (sanitation_wastewater_rabbit_fat_to_freshwater)
Rabbit fat to freshwater is one separately quantified elementary exchange from a documented direct discharge. It is not reported when the effluent goes to sewer without a direct freshwater release.
- Selected flow: Rabbit fat to freshwater
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single discharged substance or water quantity from matched effluent-flow and sampling records for the reporting period; use non-detect treatment and units stated by the laboratory, with no PCR default concentration.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Chicken fat to freshwater (sanitation_wastewater_chicken_fat_to_freshwater)
Chicken fat to freshwater is one separately quantified elementary exchange from a documented direct discharge. It is not reported when the effluent goes to sewer without a direct freshwater release.
- Selected flow: Chicken fat to freshwater
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single discharged substance or water quantity from matched effluent-flow and sampling records for the reporting period; use non-detect treatment and units stated by the laboratory, with no PCR default concentration.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Duck fat to freshwater (sanitation_wastewater_duck_fat_to_freshwater)
Duck fat to freshwater is one separately quantified elementary exchange from a documented direct discharge. It is not reported when the effluent goes to sewer without a direct freshwater release.
- Selected flow: Duck fat to freshwater
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single discharged substance or water quantity from matched effluent-flow and sampling records for the reporting period; use non-detect treatment and units stated by the laboratory, with no PCR default concentration.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Seal oil to freshwater (sanitation_wastewater_seal_oil_to_freshwater)
Seal oil to freshwater is one separately quantified elementary exchange from a documented direct discharge. It is not reported when the effluent goes to sewer without a direct freshwater release.
- Selected flow: Seal oil to freshwater
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single discharged substance or water quantity from matched effluent-flow and sampling records for the reporting period; use non-detect treatment and units stated by the laboratory, with no PCR default concentration.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Whale oil to freshwater (sanitation_wastewater_whale_oil_to_freshwater)
Whale oil to freshwater is one separately quantified elementary exchange from a documented direct discharge. It is not reported when the effluent goes to sewer without a direct freshwater release.
- Selected flow: Whale oil to freshwater
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single discharged substance or water quantity from matched effluent-flow and sampling records for the reporting period; use non-detect treatment and units stated by the laboratory, with no PCR default concentration.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Rapeseed oil to freshwater (sanitation_wastewater_rapeseed_oil_to_freshwater)
Rapeseed oil to freshwater is one separately quantified elementary exchange from a documented direct discharge. It is not reported when the effluent goes to sewer without a direct freshwater release.
- Selected flow: Rapeseed oil to freshwater
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single discharged substance or water quantity from matched effluent-flow and sampling records for the reporting period; use non-detect treatment and units stated by the laboratory, with no PCR default concentration.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Sunflower oil to freshwater (sanitation_wastewater_sunflower_oil_to_freshwater)
Sunflower oil to freshwater is one separately quantified elementary exchange from a documented direct discharge. It is not reported when the effluent goes to sewer without a direct freshwater release.
- Selected flow: Sunflower oil to freshwater
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single discharged substance or water quantity from matched effluent-flow and sampling records for the reporting period; use non-detect treatment and units stated by the laboratory, with no PCR default concentration.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Water to freshwater (sanitation_wastewater_water_to_freshwater)
Water to freshwater is one separately quantified elementary exchange from a documented direct discharge. It is not reported when the effluent goes to sewer without a direct freshwater release.
- Selected flow: Water to freshwater
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single discharged substance or water quantity from matched effluent-flow and sampling records for the reporting period; use non-detect treatment and units stated by the laboratory, with no PCR default concentration.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Carbon dioxide, biogenic to air (sanitation_wastewater_carbon_dioxide_biogenic_to_air)
Carbon dioxide, biogenic to air is one chemical-species-specific direct emission from the declared on-site treatment operation.
- Selected flow: Carbon dioxide, biogenic to air
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single air emission from facility monitoring or a documented site-specific treatment mass balance; no PCR default factor is supplied.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Methane, biogenic to air (sanitation_wastewater_methane_biogenic_to_air)
Methane, biogenic to air is one chemical-species-specific direct emission from the declared on-site treatment operation.
- Selected flow: Methane, biogenic to air
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single air emission from facility monitoring or a documented site-specific treatment mass balance; no PCR default factor is supplied.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Dinitrogen monoxide to air (sanitation_wastewater_dinitrogen_monoxide_to_air)
Dinitrogen monoxide to air is one chemical-species-specific direct emission from the declared on-site treatment operation.
- Selected flow: Dinitrogen monoxide to air
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single air emission from facility monitoring or a documented site-specific treatment mass balance; no PCR default factor is supplied.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Ammonia to air (sanitation_wastewater_ammonia_to_air)
Ammonia to air is one chemical-species-specific direct emission from the declared on-site treatment operation.
- Selected flow: Ammonia to air
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single air emission from facility monitoring or a documented site-specific treatment mass balance; no PCR default factor is supplied.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
Hydrogen sulfide to air (sanitation_wastewater_hydrogen_sulfide_to_air)
Hydrogen sulfide to air is one chemical-species-specific direct emission from the declared on-site treatment operation.
- Selected flow: Hydrogen sulfide to air
- Flow property / unit: Mass / kg
- Amount rule: Calculate this single air emission from facility monitoring or a documented site-specific treatment mass balance; no PCR default factor is supplied.
- Value mode: Calculated value (
calculated_value) - Specificity: Technology-specific (
technology_specific) - Normalization basis: per 1 kg output from this process
- Basis kind: Process output (
process_output) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_sanitation_wastewater_emission - Sources:
eu-jrc-sa-bref-2024,codex-cxc-58-2005,eu-pef-2021-2279
7. Allocation and Co-product Handling
| rule_id | Applies to | Rule | Sources |
|---|---|---|---|
| al_subdivision | All foreground operations | First subdivide processes, meters, batch records, and route-specific equipment so that direct attribution is used wherever feasible. Do not allocate an exchange to an operation that demonstrably did not use or emit it. | eu-pef-2021-2279 |
| al_mass_balance | Animal material, ingredients, products, co-products, and wastes | Close the lot mass balance before allocation. A reported co-product must have a documented function and destination; otherwise retain it as a waste to its actual management route. | eu-pef-2021-2279, eu-jrc-sa-bref-2024 |
| al_avoid_double_count | Broth, drippings, bone, adipose tissue, spent liquid, and rejects | Use the product card only for documented beneficial output and the waste card only for documented waste management. Never report the same physical mass in both alternatives. | eu-pef-2021-2279 |
| al_residual | Unavoidable shared multi-output operation | After subdivision, apply an established physical causal relation when it represents the operation. If no defensible physical relation exists, apply economic allocation using contemporaneous, geography-matched, quality-documented prices and disclose the sensitivity. | eu-pef-2021-2279 |
| al_waste_recovery | Waste sent to recovery | Do not assign an avoided-product credit inside the foreground inventory unless the selected study method explicitly requires it and the substitution, quality, yield, and system-boundary treatment are documented. Preserve waste mass and destination before any downstream modelling. | eu-pef-2021-2279 |
| al_upstream | Purchased inputs | Retain the allocation method of a qualified supplier dataset and disclose material deviations; do not recreate upstream slaughter allocation inside this foreground process unless the facility is integrated and separately modelled. | eu-pef-2021-2279, eu-jrc-sa-bref-2024 |
Raw downloads
These files are byte-identical to the canonical files for this revision in the repository.
Complete field inspector
Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.