TianGong PCR产品类别规则

Meat of sheep, frozen · Process: Cleaning and disinfection (cleaning_and_disinfection)

Meat of sheep, frozen · Process: Cleaning and disinfection (cleaning_and_disinfection): Grid electricity used for cleaning and disinfection is recorded independently…

Lifecycle status
Candidate
Content maturity
Authored methodology
Current version
No published version
Readiness
Review required
Last updated

Methodology and translation states come from the source record; publishing this website does not change their review status.

Content languages

zh-CN · Aligned
Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:21135 · exact

Source

Process: Cleaning and disinfection (cleaning_and_disinfection)

Inputs

Product flows
Cleaning and disinfection grid electricity (cleaning_electricity)

Grid electricity used for cleaning and disinfection is recorded independently from all thermal carriers.

  • Selected flow: Electricity, grid
  • Flow property / unit: Energy / kWh
  • Amount rule: Measured or sub-meter-allocated grid electricity used by cleaning and disinfection
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming frozen sheep meat released
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Cleaning and disinfection purchased steam (cleaning_purchased_steam)

Purchased steam used for cleaning and disinfection is recorded separately from hot water and fuels.

  • Selected flow: Purchased steam
  • Flow property / unit: Mass / kg
  • Amount rule: Measured purchased steam assigned to cleaning and disinfection when used
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming frozen sheep meat released
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Cleaning and disinfection purchased hot water (cleaning_purchased_hot_water)

Purchased hot water used for cleaning and disinfection is recorded separately from steam.

  • Selected flow: Purchased hot water
  • Flow property / unit: Mass / kg
  • Amount rule: Measured purchased hot-water mass assigned to cleaning and disinfection when used
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming frozen sheep meat released
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Cleaning and disinfection natural gas (cleaning_natural_gas)

Natural gas used by equipment serving cleaning and disinfection is recorded independently from diesel and LPG.

  • Selected flow: Natural gas
  • Flow property / unit: Energy / MJ
  • Amount rule: Metered natural-gas energy assigned to cleaning and disinfection using the documented calorific-value convention
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming frozen sheep meat released
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Cleaning and disinfection diesel (cleaning_diesel)

Diesel used by directly operated equipment serving cleaning and disinfection is recorded independently.

  • Selected flow: Diesel fuel
  • Flow property / unit: Mass / kg
  • Amount rule: Metered or stock-reconciled diesel mass assigned to cleaning and disinfection when used
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming frozen sheep meat released
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Cleaning and disinfection LPG (cleaning_lpg)

LPG used by equipment serving cleaning and disinfection is recorded independently from natural gas and diesel.

  • Selected flow: Liquefied petroleum gas
  • Flow property / unit: Mass / kg
  • Amount rule: Stock-reconciled LPG mass assigned to cleaning and disinfection when used
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming frozen sheep meat released
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Cleaning and disinfection process water (cleaning_process_water)

Fresh process water used for cleaning and disinfection is measured separately from internally reused water.

  • Selected flow: Process water
  • Flow property / unit: Volume / m3
  • Amount rule: Measured fresh process-water intake assigned to cleaning and disinfection
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming frozen sheep meat released
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Sodium hydroxide cleaning solution (cleaning_sodium_hydroxide)

Sodium hydroxide cleaning solution is recorded separately from every other cleaner and disinfectant.

  • Selected flow: Sodium hydroxide cleaning solution
  • Flow property / unit: Mass / kg formulated product
  • Amount rule: Measured issued sodium hydroxide cleaning solution mass minus documented unused return
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg net conforming frozen sheep meat released
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Nitric acid cleaning solution (cleaning_nitric_acid)

Nitric acid cleaning solution is recorded separately from every other cleaner and disinfectant.

  • Selected flow: Nitric acid cleaning solution
  • Flow property / unit: Mass / kg formulated product
  • Amount rule: Measured issued nitric acid cleaning solution mass minus documented unused return
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg net conforming frozen sheep meat released
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Sodium hypochlorite disinfectant (cleaning_sodium_hypochlorite)

Sodium hypochlorite disinfectant is recorded separately from every other cleaner and disinfectant.

  • Selected flow: Sodium hypochlorite disinfectant
  • Flow property / unit: Mass / kg formulated product
  • Amount rule: Measured issued sodium hypochlorite disinfectant mass minus documented unused return
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg net conforming frozen sheep meat released
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Peracetic acid disinfectant (cleaning_peracetic_acid)

Peracetic acid disinfectant is recorded separately from every other cleaner and disinfectant.

  • Selected flow: Peracetic acid disinfectant
  • Flow property / unit: Mass / kg formulated product
  • Amount rule: Measured issued peracetic acid disinfectant mass minus documented unused return
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg net conforming frozen sheep meat released
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Sanitation wastewater (cleaning_disinfection_wastewater)

Wastewater generated by cleaning and disinfection is measured separately from production-stage wastewater.

  • Selected flow: Sanitation wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Measured sanitation wastewater volume transferred to treatment or off-site destination
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming frozen sheep meat released
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Cleaning solid residue (cleaning_solid_residue_waste)

Solid residue collected during cleaning is weighed separately from wastewater-treatment sludge.

  • Selected flow: Cleaning solid residue
  • Flow property / unit: Mass / kg
  • Amount rule: Measured cleaning-residue mass sent to the documented waste destination
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming frozen sheep meat released
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Elementary flows
Cleaning and disinfection fossil carbon dioxide emission (cleaning_carbon_dioxide_air)

Fossil carbon dioxide from fuels used for cleaning and disinfection is reported as its own air exchange.

  • Selected flow: Carbon dioxide, fossil, to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculated from each measured cleaning and disinfection fuel amount and its documented carbon or emission factor
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming frozen sheep meat released
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Cleaning and disinfection nitrogen oxides emission (cleaning_nitrogen_oxides_air)

Nitrogen oxides from fuel combustion serving cleaning and disinfection are reported separately from sulfur dioxide.

  • Selected flow: Nitrogen oxides to air
  • Flow property / unit: Mass / kg NO2-equivalent
  • Amount rule: Measured or calculated from stage fuel use, equipment records and the documented NOx factor
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming frozen sheep meat released
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Cleaning and disinfection sulfur dioxide emission (cleaning_sulfur_dioxide_air)

Sulfur dioxide from fuel combustion serving cleaning and disinfection is reported separately from nitrogen oxides.

  • Selected flow: Sulfur dioxide to air
  • Flow property / unit: Mass / kg
  • Amount rule: Measured or calculated from stage fuel use, sulfur content and equipment records
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming frozen sheep meat released
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Cleaning and disinfection fine particulate emission (cleaning_pm25_air)

Fine particulate matter from fuel combustion serving cleaning and disinfection is reported as a size-specific air exchange.

  • Selected flow: Particulate matter, <2.5 um, to air
  • Flow property / unit: Mass / kg
  • Amount rule: Measured or calculated from stage fuel use and equipment-specific records
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net conforming frozen sheep meat released
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef

Process: On-site wastewater treatment (onsite_wastewater_treatment)

Inputs

Product flows
On-site wastewater treatment grid electricity (wastewater_treatment_electricity)

Grid electricity used for on-site wastewater treatment is recorded independently from all thermal carriers.

  • Selected flow: Electricity, grid
  • Flow property / unit: Energy / kWh
  • Amount rule: Measured or sub-meter-allocated grid electricity used by on-site wastewater treatment
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per m3 wastewater treated on site
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
On-site wastewater treatment purchased steam (wastewater_treatment_purchased_steam)

Purchased steam used for on-site wastewater treatment is recorded separately from hot water and fuels.

  • Selected flow: Purchased steam
  • Flow property / unit: Mass / kg
  • Amount rule: Measured purchased steam assigned to on-site wastewater treatment when used
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per m3 wastewater treated on site
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
On-site wastewater treatment purchased hot water (wastewater_treatment_purchased_hot_water)

Purchased hot water used for on-site wastewater treatment is recorded separately from steam.

  • Selected flow: Purchased hot water
  • Flow property / unit: Mass / kg
  • Amount rule: Measured purchased hot-water mass assigned to on-site wastewater treatment when used
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per m3 wastewater treated on site
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
On-site wastewater treatment natural gas (wastewater_treatment_natural_gas)

Natural gas used by equipment serving on-site wastewater treatment is recorded independently from diesel and LPG.

  • Selected flow: Natural gas
  • Flow property / unit: Energy / MJ
  • Amount rule: Metered natural-gas energy assigned to on-site wastewater treatment using the documented calorific-value convention
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per m3 wastewater treated on site
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
On-site wastewater treatment diesel (wastewater_treatment_diesel)

Diesel used by directly operated equipment serving on-site wastewater treatment is recorded independently.

  • Selected flow: Diesel fuel
  • Flow property / unit: Mass / kg
  • Amount rule: Metered or stock-reconciled diesel mass assigned to on-site wastewater treatment when used
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per m3 wastewater treated on site
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
On-site wastewater treatment LPG (wastewater_treatment_lpg)

LPG used by equipment serving on-site wastewater treatment is recorded independently from natural gas and diesel.

  • Selected flow: Liquefied petroleum gas
  • Flow property / unit: Mass / kg
  • Amount rule: Stock-reconciled LPG mass assigned to on-site wastewater treatment when used
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per m3 wastewater treated on site
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
On-site wastewater treatment process water (wastewater_treatment_process_water)

Fresh process water used for on-site wastewater treatment is measured separately from internally reused water.

  • Selected flow: Process water
  • Flow property / unit: Volume / m3
  • Amount rule: Measured fresh process-water intake assigned to on-site wastewater treatment
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per m3 wastewater treated on site
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Ferric chloride treatment solution (wastewater_treatment_ferric_chloride)

Ferric chloride solution used for on-site treatment is recorded separately from polymer flocculant.

  • Selected flow: Ferric chloride solution
  • Flow property / unit: Mass / kg formulated product
  • Amount rule: Measured ferric-chloride solution mass issued to on-site treatment
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per m3 wastewater treated on site
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Polyacrylamide flocculant (wastewater_treatment_polyacrylamide)

Polyacrylamide flocculant used for on-site treatment is recorded as one specified chemical input.

  • Selected flow: Polyacrylamide flocculant
  • Flow property / unit: Mass / kg formulated product
  • Amount rule: Measured polyacrylamide flocculant mass issued to on-site treatment
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per m3 wastewater treated on site
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Waste flows
Ordinary slaughterhouse wastewater input (ordinary_wastewater_input)

Ordinary wastewater entering on-site treatment is measured separately from high-organic-load wastewater.

  • Selected flow: Ordinary slaughterhouse wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Measured ordinary wastewater volume entering on-site treatment
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per m3 wastewater treated on site
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
High-organic-load wastewater input (high_load_wastewater_input)

High-organic-load wastewater entering on-site treatment is measured independently from ordinary wastewater.

  • Selected flow: High-organic-load slaughterhouse wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Measured high-organic-load wastewater volume entering on-site treatment
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per m3 wastewater treated on site
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Elementary flows

Outputs

Product flows
Waste flows
Treated slaughterhouse wastewater (treated_slaughterhouse_wastewater)

Treated wastewater leaving the on-site plant is recorded before discharge or off-site transfer.

  • Selected flow: Treated slaughterhouse wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Measured treated-wastewater volume leaving the on-site plant
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per m3 wastewater treated on site
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Wastewater-treatment sludge (wastewater_treatment_sludge)

Sludge removed from on-site wastewater treatment is weighed as a distinct waste stream.

  • Selected flow: Slaughterhouse wastewater-treatment sludge
  • Flow property / unit: Mass / kg wet sludge
  • Amount rule: Measured wet sludge mass sent to the documented destination
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per m3 wastewater treated on site
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Wastewater-treatment screenings (wastewater_treatment_screenings)

Screenings removed during on-site wastewater treatment are weighed separately from sludge.

  • Selected flow: Slaughterhouse wastewater screenings
  • Flow property / unit: Mass / kg
  • Amount rule: Measured screenings mass sent to the documented waste destination
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per m3 wastewater treated on site
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Elementary flows
Chemical oxygen demand emission to water (wastewater_treatment_chemical_oxygen_demand_water)

Chemical oxygen demand to water from the on-site treatment discharge is reported as its own water exchange.

  • Selected flow: Chemical oxygen demand to water
  • Flow property / unit: Mass / kg
  • Amount rule: Measured discharge volume multiplied by the matched COD concentration
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per m3 wastewater treated on site
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_onsite_wastewater_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Total nitrogen emission to water (wastewater_treatment_total_nitrogen_water)

Total nitrogen to water from the on-site treatment discharge is reported as its own water exchange.

  • Selected flow: Total nitrogen to water
  • Flow property / unit: Mass / kg
  • Amount rule: Measured discharge volume multiplied by the matched total-nitrogen concentration
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per m3 wastewater treated on site
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_onsite_wastewater_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Total phosphorus emission to water (wastewater_treatment_total_phosphorus_water)

Total phosphorus to water from the on-site treatment discharge is reported as its own water exchange.

  • Selected flow: Total phosphorus to water
  • Flow property / unit: Mass / kg
  • Amount rule: Measured discharge volume multiplied by the matched total-phosphorus concentration
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per m3 wastewater treated on site
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_onsite_wastewater_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Total suspended solids emission to water (wastewater_treatment_total_suspended_solids_water)

Total suspended solids to water from the on-site treatment discharge is reported as its own water exchange.

  • Selected flow: Total suspended solids to water
  • Flow property / unit: Mass / kg
  • Amount rule: Measured discharge volume multiplied by the matched total-suspended-solids concentration
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per m3 wastewater treated on site
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_onsite_wastewater_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
On-site wastewater treatment fossil carbon dioxide emission (wastewater_treatment_carbon_dioxide_air)

Fossil carbon dioxide from fuels used for on-site wastewater treatment is reported as its own air exchange.

  • Selected flow: Carbon dioxide, fossil, to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculated from each measured on-site wastewater treatment fuel amount and its documented carbon or emission factor
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per m3 wastewater treated on site
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_onsite_wastewater_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
On-site wastewater treatment nitrogen oxides emission (wastewater_treatment_nitrogen_oxides_air)

Nitrogen oxides from fuel combustion serving on-site wastewater treatment are reported separately from sulfur dioxide.

  • Selected flow: Nitrogen oxides to air
  • Flow property / unit: Mass / kg NO2-equivalent
  • Amount rule: Measured or calculated from stage fuel use, equipment records and the documented NOx factor
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per m3 wastewater treated on site
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_onsite_wastewater_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
On-site wastewater treatment sulfur dioxide emission (wastewater_treatment_sulfur_dioxide_air)

Sulfur dioxide from fuel combustion serving on-site wastewater treatment is reported separately from nitrogen oxides.

  • Selected flow: Sulfur dioxide to air
  • Flow property / unit: Mass / kg
  • Amount rule: Measured or calculated from stage fuel use, sulfur content and equipment records
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per m3 wastewater treated on site
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_onsite_wastewater_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
On-site wastewater treatment fine particulate emission (wastewater_treatment_pm25_air)

Fine particulate matter from fuel combustion serving on-site wastewater treatment is reported as a size-specific air exchange.

  • Selected flow: Particulate matter, <2.5 um, to air
  • Flow property / unit: Mass / kg
  • Amount rule: Measured or calculated from stage fuel use and equipment-specific records
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per m3 wastewater treated on site
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_onsite_wastewater_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef

7. Allocation and Co-product Handling

rule_idApplies toRulesource_ids
allocation_avoid_by_subdivisionMulti-output slaughter and cuttingFirst subdivide receiving, slaughter, dressing, freezing, packaging, sanitation and wastewater treatment using meters, batch records and transfer measurements so directly attributable burdens require no allocation.ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
allocation_product_statusBlood, sheepskin, edible organs, fat and bonesTreat a stream as a co-product only when it has documented product status and a beneficial destination; otherwise keep its treatment burden as waste.ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
allocation_residual_shared_burdensSaleable meat and co-productsAfter subdivision, allocate only residual shared burdens using the governing study method; document the physical or economic relation, factors, reference period and affected processes.eu-recommendation-2021-2279-pef
allocation_waste_no_creditCondemned carcass, digestive contents, rejected material, wastewater, sludge and packaging wasteDo not assign avoided-product credit solely because a waste stream has incidental revenue; disclose downstream treatment and any separately justified recovery model.ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
allocation_consistency_and_sensitivityForeground and upstream datasetsPreserve disclosed upstream allocation, apply one consistent foreground method during the reference period and test a material alternative when the allocation choice materially changes the reference-product result.eu-recommendation-2021-2279-pef

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_receiving_lairage_recordslive_sheep_receiving_and_lairageLive sheep; stage utilities; accepted sheep; dead-on-arrival sheep; manure; lairage wastewater; direct air emissionsWeighbridge or livestock scale, receipt log, meter, invoice, stock record and waste transfer recordtimestamp; lot; supplier and origin; live weight; acceptance; meter or stock quantity by exact carrier; water; output mass or volume; destination; emission measurement or factorRecord each receipt and exact exchange, then reconcile accepted live weight to slaughter transferkg, kWh, MJ or m3 as specified by the cardEach receipt and each meter periodAt least one representative continuous 12-month period or every campaign in a disclosed shorter seasonal periodEvery included receiving and lairage areaAggregate only identical exchanges within the same site and period; retain rejected lots and destinations separatelyScale and meter calibration; supplier record; invoice; stock reconciliation; signed waste transfer record
cp_slaughter_recordsslaughter_bleeding_skinning_eviscerationAccepted sheep; stage utilities; carcass; blood; sheepskin; organs; digestive contents; condemned carcass; high-load wastewater; direct air emissionsSlaughter lot record, calibrated scale, meter, collection vessel record, laboratory result and waste transfer recordlot; input live weight; carcass mass; exact co-product or waste identity; mass; wastewater volume; destination; meter or stock quantity; emission basisRecord each slaughter lot and separately weigh or meter every named output and utilitykg, kWh, MJ or m3 as specified by the cardEach lot or production shiftSame period as reference-product outputEvery included slaughter lineReconcile live weight, carcass, co-products, wastes and quantified losses by lot and reporting periodScale and meter calibration; signed lot record; inspection or release record; destination evidence; mass-balance worksheet
cp_dressing_cutting_recordscarcass_dressing_and_cuttingCarcass; stage utilities; meat cuts; fat; bones; trimmings; off-spec meat; wastewater; direct air emissionsCutting-lot record, calibrated scale, meter, product release and waste recordlot; carcass input; net meat output; exact co-product or waste identity; mass; wastewater volume; destination; meter or stock quantity; emission basisRecord each dressing or cutting lot and preserve bone-in or boneless product identitykg, kWh, MJ or m3 as specified by the cardEach lot or shiftSame period as reference-product outputEvery included dressing and cutting lineReconcile input carcass mass to meat, co-products, wastes and stock change without merging stream identitiesScale and meter calibration; cut specification; release record; waste record; reconciliation worksheet
cp_freezing_recordsprechilling_and_freezingUnfrozen meat; stage utilities; R-717; R-134a; frozen intermediate; defrost wastewater; off-spec meat; direct emissionsBatch or continuous-line record, energy meter, refrigerant service and inventory record, temperature log and scalelot; input and output mass; start and end time; declared frozen-state evidence; electricity and each thermal carrier; refrigerant stock, purchase, recharge, recovery and closing stock; wastewater; rejectsRecord each freezing lot or campaign and reconcile product, energy, refrigerant and wastewater recordskg, kWh, MJ, m3 and recorded temperature unitEach lot or campaign; refrigerant at each service eventSame period as reference-product outputEvery included pre-chilling and freezing systemKeep each energy carrier and refrigerant separate; calculate net refrigerant loss by substance; aggregate only conforming like product formsScale, meter and temperature-sensor calibration; service certificate; stock reconciliation; batch release
cp_packaging_storage_release_recordspackaging_frozen_storage_and_releaseFrozen meat; exact packaging products; stage utilities; R-717; R-134a; reference product; product loss; each packaging waste; wastewater; direct emissionsFiller or packing scale, packaging issue record, warehouse movement, refrigerant record, meter and release recordlot; frozen input; net packed output; exact packaging identity and mass; return and reuse; waste mass; storage time and condition; refrigerant fields; meter quantity; release statusRecord each lot through released warehouse quantity and exclude packaging from net product masskg, kWh, MJ, m3 and recorded storage-condition unitEach lot plus continuous storage metersSame period as reference-product outputEvery included packing line and on-site frozen storeNet product excludes packaging; keep every product, packaging material, waste and refrigerant identity separateScale and meter calibration; packaging specification; warehouse reconciliation; release record; refrigerant service evidence
cp_cleaning_disinfection_recordscleaning_and_disinfectionStage utilities; sodium hydroxide; nitric acid; sodium hypochlorite; peracetic acid; sanitation wastewater; solid residue; direct air emissionsSanitation schedule, chemical issue record, water and energy meter, wastewater record and residue transfer recordserviced process; time; exact chemical; formulated mass and concentration; unused return; water; energy carrier; wastewater volume; residue mass; destination; emission basisRecord each sanitation event and allocate only shared service using a documented causal driverkg, kWh, MJ or m3 as specified by the cardEach sanitation event and meter periodSame period as reference-product outputAll sanitation serving included processesKeep each chemical and energy carrier separate; do not double count water reused internallyChemical certificate and issue reconciliation; meter calibration; sanitation verification; wastewater and waste record
cp_onsite_wastewater_recordsonsite_wastewater_treatmentOrdinary wastewater; high-load wastewater; exact treatment chemicals; stage utilities; treated wastewater; sludge; screenings; air and water emissionsInfluent and effluent meter, composite sample, laboratory report, chemical issue, energy meter, sludge scale and transfer recorddate and time; influent class and volume; chemical identity and quantity; energy carrier; effluent volume; COD; total nitrogen; total phosphorus; suspended solids; sludge and screenings mass; destination; air-emission basisMatch flow-weighted samples to discharge volume and keep ordinary and high-load influent separatekg, kWh, MJ, m3 and concentration unitContinuous volume with sampling frequency disclosedSame period as reference-product outputEvery included on-site treatment line and discharge pointCalculate each water pollutant independently from matched volume and concentration; separately reconcile sludge and screeningsFlowmeter and laboratory QA; sampling plan; chemical issue; sludge scale; discharge and transfer records

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
calc_reference_normalizationAll included inventorynormalized amount = reporting-period exchange amount divided by net conforming frozen sheep-meat mass released; packaging is excluded from the denominatorperiod exchange amount; released net reference-product massamount per 1 kg reference producteu-recommendation-2021-2279-pef
calc_process_mass_balanceEach foreground processopening stock plus external and internal inputs equals closing stock plus products, co-products, wastes, internal transfers and quantified loss; report the residual without forcing closurestock, input, output, transfer and reject recordsprocess mass-balance residualec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
calc_live_to_carcass_reconciliationReceiving and slaughterreconcile accepted live weight to dressed carcass, blood, skin, organs, digestive contents, condemned material and documented residuallive-weight, carcass and separated-stream recordsslaughter mass-balance residualec-jrc-sa-bref-2024
calc_stage_utility_allocationShared utilitiesassign a directly metered quantity first; allocate only the reconciled shared residual using a documented causal driver such as operating time, throughput or measured loadsub-meter, site total, export, operating driver and process outputcarrier amount by processec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
calc_combustion_emissionsNatural gas, diesel and LPG usecalculate each named air emission from the measured fuel amount and the documented site measurement or emission factor; preserve factor basis and fuel conventionfuel amount; measured concentration or factor; operating recordkg of each named air emissionec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
calc_refrigerant_lossR-717 and R-134a systemsunrecovered loss = opening stock plus purchases plus recharge transfers in minus recovered quantity minus closing stock minus documented transfers out; calculate separately by substancerefrigerant stock and service recordskg make-up and kg unrecovered emission by substanceec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
calc_wastewater_loadOn-site treatment dischargepollutant load = matched treated-wastewater volume multiplied by the measured concentration; calculate COD, total nitrogen, total phosphorus and suspended solids independentlydischarge volume; matched concentration; sampling periodkg of each named water emissionec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
calc_coproduct_allocationResidual shared burdensallocated burden for output i = residual shared burden multiplied by the disclosed allocation factor for output i; factors shall sum to one across the allocated outputsresidual burden; product quantities; physical relation or economic value; reference periodallocated residual burden and sensitivity resulteu-recommendation-2021-2279-pef

Data Quality Requirements

requirement_idApplies toRequirementEvidence
dq_product_identityReference product and intermediate meatDemonstrate sheep species, frozen state, product form, bone status, lot identity and conformity; do not use the CPC 21135 UUID for edible offal or prepared meat.Product specification; lot record; release record; selected Tiangong UUID
dq_temporal_representativenessAll foreground recordsUse one representative continuous 12-month period for year-round operation or all production campaigns in a shorter disclosed seasonal period; register gaps and substitutions.Meter and batch coverage; production calendar; gap register
dq_geographic_and_technical_scopeSite and upstream datasetsMatch actual slaughter geography, sheep supply, process technology, freezing system and wastewater route; disclose every proxy and material mismatch.Site metadata; supplier origin; equipment records; dataset geography and technology
dq_inventory_completenessAll included processesCover all known energy, water, material and chemical inputs and every product, co-product, waste and direct emission output; document a specific non-applicability or cut-off reason for omissions.Complete LCI checklist; bills; stock records; meters; batch and waste records
dq_mass_balanceSheep, carcass, meat and separated streamsReconcile live weight and each process mass balance, disclose measurement uncertainty and investigate material residuals instead of inserting an unmeasured loss.Signed balance worksheets; calibrated scales; residual investigation
dq_cold_chain_and_releasePre-chilling, freezing and frozen storageRetain lot-linked evidence of the declared frozen state, storage condition, duration and release status without inventing a default temperature or residence time.Temperature log; sensor calibration; warehouse movement; release record
dq_emissions_and_wastewaterAir and water emissionsLink every calculated emission to measured activity data, a documented measurement or factor, applicable compartment and reference period.Measurement report; factor source; fuel record; laboratory QA; calculation worksheet
dq_coproduct_and_waste_statusBlood, skin, organs, fat, bones and rejected materialDocument destination and legal or commercial product status for each stream before treating it as a co-product; retain waste transfer evidence otherwise.Sales or transfer record; product specification; waste manifest; allocation worksheet
dq_data_provenance_and_reviewForeground data packageRetain company-specific source records, transformations, allocation, data-quality ratings, reviewer findings and limitations sufficient to reproduce the inventory.Data lineage register; calculation workbook; review record; limitation disclosure

9. Validation Rules

rule_idApplies toRulesource_ids
validation_reference_identityReference flowThe selected flow UUID shall be 7a898ac1-b845-4943-bae3-94e7c24ae06d, a Product flow for exact CPC 21135 using Mass and kg; do not apply it to fresh or chilled sheep meat, edible offal, other species or prepared meat.un-cpc-3-0
validation_reference_amountQuantitative referenceThe reference output shall equal exactly 1 kg net conforming frozen sheep meat using Mass 93a60a56-a3c8-11da-a746-0800200b9a66 and kg from unit group 93a60a57-a4c8-11da-a746-0800200c9a66; packaging mass shall be excluded.un-cpc-3-0
validation_process_selectionProcess mapInclude all six required processes and include onsite_wastewater_treatment whenever wastewater is treated at the represented facility.ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
validation_atomic_inventoryForeground inventoryEach card shall contain one exact exchange and one property-unit pair. Reject collection labels, selectors, combined energy carriers, multiple chemicals, multiple packaging materials, multiple wastes or multiple emissions in one Selected flow.ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
validation_inventory_coverageForeground inventoryVerify separate cards for live sheep, stage water and each energy carrier, each refrigerant make-up and emission, each cleaner and disinfectant, each packaging product and packaging waste, each product or co-product, each waste stream and each direct air or water emission actually present.ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
validation_mass_balanceForeground processesReport process and reporting-period mass-balance residuals with measurement uncertainty and investigate material residuals; do not fabricate closure.ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
validation_frozen_stateReference productDemonstrate the declared frozen state and preserve lot-linked pre-chilling, freezing, frozen-storage duration, condition and release evidence; no default temperature or duration may be inferred.un-cpc-3-0; ec-jrc-sa-bref-2024
validation_no_utility_double_countingUtilitiesVerify that purchased steam and fuels, purchased hot water and its upstream heat supply, fresh and reused water, and shared utility allocations are each counted once.ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
validation_refrigerantsRefrigerationReconcile each refrigerant substance independently; a make-up product flow and its corresponding unrecovered air emission shall not be merged or duplicated.ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
validation_wastewaterWastewater and on-site treatmentKeep ordinary and high-organic-load wastewater distinct, reconcile influent, effluent and sludge, and calculate each reported water emission from matched flow and concentration records.ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
validation_allocationCo-products and shared operationsSubdivide directly attributable burdens before allocation; residual allocation factors shall sum to one and the method, period, product status and material sensitivity result shall be disclosed.eu-recommendation-2021-2279-pef
validation_collection_linksCollected and calculated rowsEvery collected or calculated row shall reference an implemented collection protocol; every calculation shall identify its rule or reproducible worksheet.eu-recommendation-2021-2279-pef
validation_data_quality_and_transparencyPublished data packageDisclose company-specific data coverage, sources, transformations, proxies, gaps, cut-offs, uncertainty, allocation, data quality and reviewer findings.eu-recommendation-2021-2279-pef

10. Published Dataset Profile

FieldValue
dataset_roleSite-specific foreground data package for frozen sheep meat, publishable as a unit process or reviewed gate-to-gate dataset
downstream_usesecondary_dataset; background_dataset
allowed_useAttributional product LCA, supply-chain modelling, facility improvement, hotspot analysis and comparison of like frozen sheep-meat forms when geography, technology, allocation and frozen-state specification are compatible
excluded_useClaims for fresh or chilled meat, edible offal, goat or other species, prepared meat, food-safety certification, nutrition claims, or use outside the represented geography, period and technology without representativeness review
required_metadataPCR id and lifecycle state; CPC 21135 product identity and Tiangong UUID; sheep origin; facility and geography; carcass or cut form; bone status; freezing and storage technology; frozen-storage duration and condition; reference period; system boundary; upstream datasets; packaging; wastewater route; co-product status; allocation; data owners and review status
required_quality_disclosurePrimary-data coverage; scale, meter, sensor and laboratory methods; live-weight and process mass-balance residuals; unresolved flow UUIDs; proxy datasets; temporal, geographic and technology limitations; cut-offs; allocation sensitivity; uncertainty; data-quality ratings and reviewer findings
update_triggerChange in product form, sheep supply, slaughter or freezing technology, energy system, refrigerant, packaging, wastewater route, co-product status or allocation; new verified Tiangong identity; better representative foreground data; corrected mass balance or source revision

11. Data Sources

Source idTypeReferenceUsed for
un-cpc-3-0Official guidance (official_guidance)United Nations Statistics Division. Central Product Classification, Version 3.0, structure and explanatory notes, 30 June 2025; retained raw structure file CPC_Ver_3.0_Structure_30Jun2025.csv. https://unstats.un.org/unsd/classifications/Econ/Download/In%20Text/CPC_Ver_3.0_Exp_Notes_30Jun2025.pdf. Retrieved 2026-08-13.Exact CPC 21135 frozen sheep-meat scope and exclusions from fresh or chilled meat and edible-offal categories
ec-jrc-sa-bref-2024Official guidance (official_guidance)Karlis, P., Presicce, F., Giner Santonja, G., Brinkmann, T. and Roudier, S. Best Available Techniques (BAT) Reference Document for the Slaughterhouses, Animal By-products and/or Edible Co-products Industries. European Commission Joint Research Centre, EUR 31752 EN, JRC135916, 2024. https://doi.org/10.2760/18199; https://publications.jrc.ec.europa.eu/repository/handle/JRC135916. Retrieved 2026-08-13.Slaughterhouse process decomposition, utilities, cleaning, refrigeration, wastewater, co-products, wastes, emissions and foreground quality records
eu-recommendation-2021-2279-pefOfficial guidance (official_guidance)European Commission. Commission Recommendation (EU) 2021/2279 of 15 December 2021 on the use of the Environmental Footprint methods to measure and communicate the life cycle environmental performance of products and organisations, consolidated text 30 December 2021. https://eur-lex.europa.eu/eli/reco/2021/2279/2021-12-30/eng. Retrieved 2026-08-13.Product-specific bill of materials, company-specific data, complete LCI, allocation, normalization, transparency, data quality and verification

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page

Process: Cleaning and disinfection (cleaning_and_disinfection)InputsProduct flowsCleaning and disinfection grid electricity (cleaning_electricity)Cleaning and disinfection purchased steam (cleaning_purchased_steam)Cleaning and disinfection purchased hot water (cleaning_purchased_hot_water)Cleaning and disinfection natural gas (cleaning_natural_gas)Cleaning and disinfection diesel (cleaning_diesel)Cleaning and disinfection LPG (cleaning_lpg)Cleaning and disinfection process water (cleaning_process_water)Sodium hydroxide cleaning solution (cleaning_sodium_hydroxide)Nitric acid cleaning solution (cleaning_nitric_acid)Sodium hypochlorite disinfectant (cleaning_sodium_hypochlorite)Peracetic acid disinfectant (cleaning_peracetic_acid)Waste flowsElementary flowsOutputsProduct flowsWaste flowsSanitation wastewater (cleaning_disinfection_wastewater)Cleaning solid residue (cleaning_solid_residue_waste)Elementary flowsCleaning and disinfection fossil carbon dioxide emission (cleaning_carbon_dioxide_air)Cleaning and disinfection nitrogen oxides emission (cleaning_nitrogen_oxides_air)Cleaning and disinfection sulfur dioxide emission (cleaning_sulfur_dioxide_air)Cleaning and disinfection fine particulate emission (cleaning_pm25_air)Process: On-site wastewater treatment (onsite_wastewater_treatment)InputsProduct flowsOn-site wastewater treatment grid electricity (wastewater_treatment_electricity)On-site wastewater treatment purchased steam (wastewater_treatment_purchased_steam)On-site wastewater treatment purchased hot water (wastewater_treatment_purchased_hot_water)On-site wastewater treatment natural gas (wastewater_treatment_natural_gas)On-site wastewater treatment diesel (wastewater_treatment_diesel)On-site wastewater treatment LPG (wastewater_treatment_lpg)On-site wastewater treatment process water (wastewater_treatment_process_water)Ferric chloride treatment solution (wastewater_treatment_ferric_chloride)Polyacrylamide flocculant (wastewater_treatment_polyacrylamide)Waste flowsOrdinary slaughterhouse wastewater input (ordinary_wastewater_input)High-organic-load wastewater input (high_load_wastewater_input)Elementary flowsOutputsProduct flowsWaste flowsTreated slaughterhouse wastewater (treated_slaughterhouse_wastewater)Wastewater-treatment sludge (wastewater_treatment_sludge)Wastewater-treatment screenings (wastewater_treatment_screenings)Elementary flowsChemical oxygen demand emission to water (wastewater_treatment_chemical_oxygen_demand_water)Total nitrogen emission to water (wastewater_treatment_total_nitrogen_water)Total phosphorus emission to water (wastewater_treatment_total_phosphorus_water)Total suspended solids emission to water (wastewater_treatment_total_suspended_solids_water)On-site wastewater treatment fossil carbon dioxide emission (wastewater_treatment_carbon_dioxide_air)On-site wastewater treatment nitrogen oxides emission (wastewater_treatment_nitrogen_oxides_air)On-site wastewater treatment sulfur dioxide emission (wastewater_treatment_sulfur_dioxide_air)On-site wastewater treatment fine particulate emission (wastewater_treatment_pm25_air)7. Allocation and Co-product Handling8. Foreground Data Collection, Calculation, and Quality RulesData Collection ProtocolsCalculation RulesData Quality Requirements9. Validation Rules10. Published Dataset Profile11. Data Sources