TianGong PCR产品类别规则

Meat of goat, frozen · Process: On-site slaughterhouse wastewater treatment (onsite_wastewater_treatment)

Meat of goat, frozen · Process: On-site slaughterhouse wastewater treatment (onsite_wastewater_treatment): Electricity operates pumps, aeration, separation, and sludge…

Lifecycle status
Candidate
Content maturity
Authored methodology
Current version
No published version
Readiness
Review required
Last updated

Methodology and translation states come from the source record; publishing this website does not change their review status.

Content languages

zh-CN · Aligned
Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:21136 · exact

Source

Process: On-site slaughterhouse wastewater treatment (onsite_wastewater_treatment)

Inputs

Product flows
Wastewater-treatment electricity (wwtp_electricity)

Electricity operates pumps, aeration, separation, and sludge handling within on-site treatment.

  • Selected flow: Electricity, grid supply
  • Flow property / unit: Energy / kWh
  • Amount rule: Record the treatment-plant submeter and calculate the lot share from metered treated volume or measured pollutant load.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming frozen goat meat at the facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_wwtp_inputs
  • UUID status: Unresolved; the Tiangong flow UUID is intentionally omitted.
  • Uncertainty: Document input-record uncertainty, calculation assumptions, factor provenance, and allocation uncertainty.
  • Applicability: Conditional on on-site treatment.
  • Sources: ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint
Wastewater-treatment process water (wwtp_process_water)

This input excludes wastewater being treated and reclaimed-water recirculation.

  • Selected flow: Process water
  • Flow property / unit: Volume / m3
  • Amount rule: Record metered clean water used for reagent preparation or equipment operation in on-site treatment.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming frozen goat meat at the facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwtp_inputs
  • UUID status: Unresolved; the Tiangong flow UUID is intentionally omitted.
  • Uncertainty: Document instrument resolution, calibration status, missing records, and lot-allocation uncertainty.
  • Applicability: Conditional on clean-water use in treatment.
  • Sources: ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint
Calcium hydroxide reagent (wwtp_calcium_hydroxide)

Calcium hydroxide is a single precipitation or pH-control reagent.

  • Selected flow: Calcium hydroxide
  • Flow property / unit: Mass / kg
  • Amount rule: Record issued mass from treatment-chemical stock and dosing records.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming frozen goat meat at the facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwtp_inputs
  • UUID status: Unresolved; the Tiangong flow UUID is intentionally omitted.
  • Uncertainty: Document instrument resolution, calibration status, missing records, and lot-allocation uncertainty.
  • Applicability: Conditional on calcium hydroxide dosing.
  • Sources: ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint
Aluminium sulfate reagent (wwtp_aluminium_sulfate)

Aluminium sulfate is a single phosphorus-precipitation reagent.

  • Selected flow: Aluminium sulfate
  • Flow property / unit: Mass / kg
  • Amount rule: Record issued mass from treatment-chemical stock and dosing records.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming frozen goat meat at the facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwtp_inputs
  • UUID status: Unresolved; the Tiangong flow UUID is intentionally omitted.
  • Uncertainty: Document instrument resolution, calibration status, missing records, and lot-allocation uncertainty.
  • Applicability: Conditional on aluminium sulfate dosing.
  • Sources: ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint
Ferric chloride reagent (wwtp_ferric_chloride)

Ferric chloride is a single phosphorus-precipitation reagent.

  • Selected flow: Ferric chloride
  • Flow property / unit: Mass / kg
  • Amount rule: Record issued mass from treatment-chemical stock and dosing records.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming frozen goat meat at the facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwtp_inputs
  • UUID status: Unresolved; the Tiangong flow UUID is intentionally omitted.
  • Uncertainty: Document instrument resolution, calibration status, missing records, and lot-allocation uncertainty.
  • Applicability: Conditional on ferric chloride dosing.
  • Sources: ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint
Waste flows
Routine wastewater input (wwtp_routine_wastewater_input)

Routine wastewater is one treatment input and remains separate from high-organic-load wastewater.

  • Selected flow: Routine slaughterhouse wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Sum metered routine wastewater transfers entering on-site treatment without including high-organic-load flow.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming frozen goat meat at the facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_wwtp_inputs
  • UUID status: Unresolved; the Tiangong flow UUID is intentionally omitted.
  • Uncertainty: Document input-record uncertainty, calculation assumptions, factor provenance, and allocation uncertainty.
  • Applicability: Conditional on on-site receipt of this stream.
  • Sources: ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint
High-load wastewater input (wwtp_high_load_wastewater_input)

High-organic-load wastewater is a distinct treatment input.

  • Selected flow: High-organic-load slaughterhouse wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Sum metered high-organic-load wastewater transfers entering on-site treatment without including routine flow.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming frozen goat meat at the facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_wwtp_inputs
  • UUID status: Unresolved; the Tiangong flow UUID is intentionally omitted.
  • Uncertainty: Document input-record uncertainty, calculation assumptions, factor provenance, and allocation uncertainty.
  • Applicability: Conditional on on-site receipt of this stream.
  • Sources: ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint
Elementary flows

Outputs

Product flows
Reclaimed water (wwtp_reclaimed_water)

Treated water is a product output only when quality and destination records demonstrate productive reuse.

  • Selected flow: Reclaimed process water
  • Flow property / unit: Volume / m3
  • Amount rule: Record the reclaimed-water meter at the point of transfer to an approved productive use.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming frozen goat meat at the facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwtp_outputs
  • UUID status: Unresolved; the Tiangong flow UUID is intentionally omitted.
  • Uncertainty: Document instrument resolution, calibration status, missing records, and lot-allocation uncertainty.
  • Applicability: Conditional on documented reuse.
  • Sources: ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint
Waste flows
Treated wastewater to sewer (wwtp_treated_wastewater_to_sewer)

This waste flow applies to transfer to a sewer or off-site treatment and is not a direct surface-water release.

  • Selected flow: Treated slaughterhouse wastewater to sewer
  • Flow property / unit: Volume / m3
  • Amount rule: Record the final sewer-discharge meter after on-site treatment.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming frozen goat meat at the facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwtp_outputs
  • UUID status: Unresolved; the Tiangong flow UUID is intentionally omitted.
  • Uncertainty: Document instrument resolution, calibration status, missing records, and lot-allocation uncertainty.
  • Applicability: Conditional on sewer or off-site transfer.
  • Sources: ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint
Screening solids (wwtp_screening_solids)

Screening solids are recorded separately from sludge and grease skim.

  • Selected flow: Slaughterhouse wastewater screening solids
  • Flow property / unit: Mass / kg
  • Amount rule: Record wet mass removed by screens and dispatched to waste treatment.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming frozen goat meat at the facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwtp_outputs
  • UUID status: Unresolved; the Tiangong flow UUID is intentionally omitted.
  • Uncertainty: Document instrument resolution, calibration status, missing records, and lot-allocation uncertainty.
  • Applicability: Conditional on screening.
  • Sources: ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint
Grease skim (wwtp_grease_skim)

Grease skim is recorded separately from biological and chemical sludge.

  • Selected flow: Slaughterhouse wastewater grease skim
  • Flow property / unit: Mass / kg
  • Amount rule: Record wet mass removed by grease separation or flotation and dispatched to waste treatment.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming frozen goat meat at the facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwtp_outputs
  • UUID status: Unresolved; the Tiangong flow UUID is intentionally omitted.
  • Uncertainty: Document instrument resolution, calibration status, missing records, and lot-allocation uncertainty.
  • Applicability: Conditional on grease separation.
  • Sources: ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint
Biological sludge (wwtp_biological_sludge)

Biological sludge is a distinct treatment residue.

  • Selected flow: Slaughterhouse biological wastewater sludge
  • Flow property / unit: Mass / kg
  • Amount rule: Record wet mass and measured dry-matter fraction of biological sludge leaving treatment.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming frozen goat meat at the facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwtp_outputs
  • UUID status: Unresolved; the Tiangong flow UUID is intentionally omitted.
  • Uncertainty: Document instrument resolution, calibration status, missing records, and lot-allocation uncertainty.
  • Applicability: Conditional on biological treatment.
  • Sources: ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint
Chemical precipitation sludge (wwtp_chemical_sludge)

Chemical precipitation sludge is kept separate from biological sludge.

  • Selected flow: Slaughterhouse chemical precipitation sludge
  • Flow property / unit: Mass / kg
  • Amount rule: Record wet mass and measured dry-matter fraction of sludge produced by chemical precipitation.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming frozen goat meat at the facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wwtp_outputs
  • UUID status: Unresolved; the Tiangong flow UUID is intentionally omitted.
  • Uncertainty: Document instrument resolution, calibration status, missing records, and lot-allocation uncertainty.
  • Applicability: Conditional on chemical precipitation.
  • Sources: ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint
Elementary flows
Chemical oxygen demand release (wwtp_cod_to_water)

COD is recorded as one monitored water-release parameter for direct discharge.

  • Selected flow: Chemical oxygen demand to surface water
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate discharged load from measured effluent volume and temporally matched COD concentration.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming frozen goat meat at the facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_water_discharge
  • UUID status: Unresolved; the Tiangong flow UUID is intentionally omitted.
  • Uncertainty: Document input-record uncertainty, calculation assumptions, factor provenance, and allocation uncertainty.
  • Applicability: Conditional on direct surface-water discharge.
  • Sources: ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint
Five-day biochemical oxygen demand release (wwtp_bod5_to_water)

BOD5 is recorded separately from COD.

  • Selected flow: Five-day biochemical oxygen demand to surface water
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate discharged load from measured effluent volume and temporally matched BOD5 concentration.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming frozen goat meat at the facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_water_discharge
  • UUID status: Unresolved; the Tiangong flow UUID is intentionally omitted.
  • Uncertainty: Document input-record uncertainty, calculation assumptions, factor provenance, and allocation uncertainty.
  • Applicability: Conditional on direct surface-water discharge.
  • Sources: ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint
Total nitrogen release (wwtp_total_nitrogen_to_water)

Total nitrogen is one monitored water-release parameter.

  • Selected flow: Total nitrogen to surface water
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate discharged load from measured effluent volume and temporally matched total-nitrogen concentration.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming frozen goat meat at the facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_water_discharge
  • UUID status: Unresolved; the Tiangong flow UUID is intentionally omitted.
  • Uncertainty: Document input-record uncertainty, calculation assumptions, factor provenance, and allocation uncertainty.
  • Applicability: Conditional on direct surface-water discharge.
  • Sources: ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint
Total phosphorus release (wwtp_total_phosphorus_to_water)

Total phosphorus is one monitored water-release parameter.

  • Selected flow: Total phosphorus to surface water
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate discharged load from measured effluent volume and temporally matched total-phosphorus concentration.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming frozen goat meat at the facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_water_discharge
  • UUID status: Unresolved; the Tiangong flow UUID is intentionally omitted.
  • Uncertainty: Document input-record uncertainty, calculation assumptions, factor provenance, and allocation uncertainty.
  • Applicability: Conditional on direct surface-water discharge.
  • Sources: ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint
Suspended-solids release (wwtp_tss_to_water)

Total suspended solids are recorded separately from oxygen-demand and nutrient parameters.

  • Selected flow: Total suspended solids to surface water
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate discharged load from measured effluent volume and temporally matched total-suspended-solids concentration.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming frozen goat meat at the facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_water_discharge
  • UUID status: Unresolved; the Tiangong flow UUID is intentionally omitted.
  • Uncertainty: Document input-record uncertainty, calculation assumptions, factor provenance, and allocation uncertainty.
  • Applicability: Conditional on direct surface-water discharge.
  • Sources: ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint
Treatment ammonia release (wwtp_ammonia_to_air)

Ammonia is recorded as one substance-specific direct air release from wastewater treatment.

  • Selected flow: Ammonia to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate released mass from measured exhaust flow and measured ammonia concentration for the treatment operating period.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming frozen goat meat at the facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_wwtp_air_releases
  • UUID status: Unresolved; the Tiangong flow UUID is intentionally omitted.
  • Uncertainty: Document input-record uncertainty, calculation assumptions, factor provenance, and allocation uncertainty.
  • Applicability: Conditional on a measured direct release.
  • Sources: ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint
Treatment hydrogen sulfide release (wwtp_hydrogen_sulfide_to_air)

Hydrogen sulfide is recorded separately from ammonia.

  • Selected flow: Hydrogen sulfide to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate released mass from measured exhaust flow and measured hydrogen sulfide concentration for the treatment operating period.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net conforming frozen goat meat at the facility gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_wwtp_air_releases
  • UUID status: Unresolved; the Tiangong flow UUID is intentionally omitted.
  • Uncertainty: Document input-record uncertainty, calculation assumptions, factor provenance, and allocation uncertainty.
  • Applicability: Conditional on a measured direct release.
  • Sources: ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint

7. Allocation and Co-product Handling

rule_idApplies toRulesource_ids
allocation_avoidmulti-output processesFirst avoid allocation by process subdivision and direct metering of slaughter, cutting, freezing, packaging, cleaning, and treatment activities.eu-2021-2279-environmental-footprint
allocation_expandco-products with additional functionsIf subdivision cannot resolve a co-product function, investigate transparent system expansion before partitioning burdens.eu-2021-2279-environmental-footprint
allocation_physicalremaining multi-output processWhen allocation remains necessary, use a documented physical relationship that reflects the causal use of inputs and generation of outputs.eu-2021-2279-environmental-footprint
allocation_economicremaining unresolved relationshipUse economic allocation only when neither subdivision, system expansion, nor a relevant physical relationship is defensible; use period-matched facility records and disclose sensitivity.eu-2021-2279-environmental-footprint
allocation_statuseach blood, hide, fat, organ, bone, water, and residue rowEstablish product or waste status from quality, legal status, and destination evidence before allocation; do not assign the same physical quantity to both statuses.ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint
allocation_wastewaste treatmentDo not credit a waste destination unless the selected LCA method and documented receiving function require it; disclose the modelling choice.eu-2021-2279-environmental-footprint
allocation_consistencyall process linksDo not double count an intermediate transfer, purchased heat and its upstream fuel, a refrigerant make-up and an unrelated loss, or a wastewater output and the same treatment input.eu-2021-2279-environmental-footprint

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_receiving_recordslive_goat_receivinglive-goat, electricity, water, accepted transfer, manure, and lairage wastewaterweighbridge ticket; animal acceptance log; utility meter; waste dispatch recordtimestamp; lot_id; meter_or_scale_id; opening_reading; closing_reading; gross_mass; tare_mass; destinationReconcile calibrated measurements and dispatch records to the production lot.kg; m3; kWheach lotfull study periodreceiving areasum lot records once; allocate shared electricity by documented equipment activitycalibration certificates; signed acceptance and dispatch records; meter reconciliation
cp_slaughter_inputsslaughter_dressingaccepted live-goat input, line electricity, and process watertransfer record; electricity meter; water metertimestamp; lot_id; source_process; meter_id; opening_reading; closing_readingLink receiving transfer and calibrated utility meters to the slaughter lot.kg; kWh; m3each lotfull study periodslaughter linesum direct records; allocate shared meters with documented equipment activitytransfer reconciliation; calibration; meter logs
cp_slaughter_outputsslaughter_dressingcarcass, co-product, condemned stream, contents, and wastewater outputscale record; condemnation log; destination record; wastewater metertimestamp; lot_id; row_id; gross_mass; tare_mass; destination; legal_status; flow_readingWeigh each physical output separately and document product or waste status before aggregation.kg; m3each lotfull study periodslaughter linesum each row_id once; prohibit overlap between productive and condemned destinationsscale calibration; inspection record; destination evidence; mass balance
cp_slaughter_air_releasesslaughter_dressingammonia and hydrogen sulfide direct releasesstack or capture-flow monitoring recordtimestamp; operating_state; exhaust_flow; substance; concentration; method; detection_limitMatch substance-specific concentration measurements to exhaust flow and slaughter operation.kgmonitoring campaign and each material changerepresentative operating period within study periodslaughter air-release pointsintegrate measured mass flow over applicable operating timelaboratory report; monitoring method; instrument calibration
cp_cutting_recordscarcass_cuttingcarcass input, utilities, meat output, bone, fat, trimming waste, and wastewaterscale record; submeter; destination record; wastewater metertimestamp; lot_id; row_id; mass; meter_reading; destination; legal_statusLink calibrated cutting records and each separated output to the lot.kg; kWh; m3each lotfull study periodcutting areasum each row_id once and reconcile input-output massscale and meter calibration; destination record; mass balance
cp_freezing_recordschilling_freezingmeat transfer, cold-system electricity, water, frozen output, off-spec meat, and aqueous wastesscale record; refrigeration submeter; water meter; storage occupancy log; drain metertimestamp; lot_id; mass; meter_id; opening_reading; closing_reading; storage_duration; drain_volumeLink measured cold-system activity and frozen-meat transfers to each released lot.kg; kWh; m3each lotfull study periodpre-chiller; freezer; frozen storesum direct records; allocate frozen-store electricity by measured occupancyscale and meter calibration; temperature and occupancy logs; release record
cp_refrigerant_inventorychilling_freezingR717, R744, and R290 make-up and direct releasesrefrigerant purchase; cylinder stock; service log; leak record; system charge inventorydate; circuit_id; refrigerant_code; opening_stock; receipts; closing_stock; recovered_mass; transferred_mass; leak_eventReconcile each refrigerant species and circuit independently; never substitute a combined refrigerant total.kgeach service event and annual closurefull study periodall cold-system circuits inside boundaryopening stock plus receipts minus closing stock, recovery, and documented transferspurchase invoice; cylinder weights; service certification; leak-detector log
cp_packaging_bompackaging_releaseeach packaging component inputproduct-specific BoM; issue-return record; component countlot_id; component_identity; issued_mass; returned_mass; count; unit_mass; reuse_cyclesCalculate each named packaging component from product-specific BoM and verified stock records.kgeach lotfull study periodpackaging linesum each component separately; allocate reusable pallets by documented use cyclesapproved BoM; stock ledger; unit-mass test; pallet ledger
cp_packaging_releasepackaging_releasefrozen-meat input, packaging electricity, and reference-product outputtransfer scale; electricity submeter; release scale; quality-release recordtimestamp; lot_id; input_net_mass; output_net_mass; meter_reading; release_status; temperatureDetermine net conforming product mass and packaging-line electricity for the released lot.kg; kWheach lotfull study periodpackaging and release areasum released net product once; exclude packaging massscale and meter calibration; signed release; temperature record
cp_packaging_wastepackaging_releaseoff-spec meat and each packaging wastewaste scale; reject log; component counttimestamp; lot_id; row_id; gross_mass; tare_mass; count; destinationMeasure each material-specific packaging waste and rejected meat separately.kgeach lotfull study periodpackaging areasum each row_id once; prohibit transfer of packaging mass into reference productwaste tickets; reject records; scale calibration
cp_cleaning_inputscleaning_disinfectionelectricity, water, sodium hydroxide, and sodium hypochloritesubmeter; chemical issue and dosing log; hygiene-cycle recordtimestamp; lot_id; cycle_id; substance; concentration; issued_mass; meter_readingAssign measured hygiene-cycle resources to the production lot and retain chemical identity.kg; m3; kWheach hygiene cyclefull study periodforeground hygiene systemssum each substance separately; allocate shared cycles by cleaned area or documented cycle timemeter calibration; chemical stock reconciliation; dosing log; sanitation record
cp_thermal_utilitycleaning_disinfectionpurchased steam, purchased hot water, natural gas, diesel, and liquefied petroleum gassupplier meter; boiler meter; fuel tank and purchase ledgertimestamp; lot_id; carrier_identity; quantity; temperature; pressure; heating_value; meter_idRecord each imported heat carrier or on-site fuel separately and reconcile alternative heat routes.MJeach hygiene cycle and monthly closurefull study periodthermal systems serving foreground hygieneconvert measured carrier quantity to delivered energy with documented properties; prohibit double countingsupplier invoice; calibrated meter; fuel-quality record; boiler log
cp_cleaning_wastewatercleaning_disinfectionroutine and high-organic-load cleaning wastewatersegregated drain meter; hygiene-cycle logtimestamp; lot_id; stream_identity; opening_reading; closing_reading; destinationMeasure routine and high-load cleaning streams independently.m3each hygiene cyclefull study periodcleaning drainssum each stream once by destinationdrain-meter calibration; flow diagram; dispatch or treatment record
cp_combustion_releasescleaning_disinfectioneach named on-site combustion releasefuel meter; direct monitoring; verified equipment-specific factor recordtimestamp; equipment_id; fuel_identity; fuel_quantity; substance; concentration_or_factor; factor_sourceDetermine each substance-specific release from direct measurement or a verified factor applied to measured fuel.kgeach monitoring campaign and reporting periodfull study periodon-site combustion equipment inside boundarycalculate each substance separately; exclude upstream purchased heat productionmonitoring report; fuel record; factor provenance; calculation review
cp_wwtp_inputsonsite_wastewater_treatmentwastewater inputs, electricity, water, and each treatment reagentinfluent meters; submeter; chemical dosing and stock logstimestamp; lot_id; stream_or_substance; meter_reading; issued_mass; concentration; treated_volumeMeasure each wastewater stream and reagent independently at the on-site treatment boundary.kg; m3; kWhdaily and each lot allocationfull study periodon-site wastewater-treatment plantsum each row_id separately; allocate shared treatment by measured volume or pollutant loadmeter calibration; chemical stock reconciliation; treatment log
cp_wwtp_outputsonsite_wastewater_treatmentreclaimed water, sewer wastewater, screening solids, grease skim, and each sludgeoutlet meter; waste scale; destination and quality recordtimestamp; row_id; volume; wet_mass; dry_matter; quality_result; destinationMeasure each treatment output separately and establish product or waste status from quality and destination.kg; m3daily and each dispatchfull study periodon-site wastewater-treatment plantsum each row_id once; keep reuse, sewer transfer, and residue destinations distinctmeter and scale calibration; laboratory result; dispatch record
cp_water_dischargeonsite_wastewater_treatmentCOD, BOD5, total nitrogen, total phosphorus, and total suspended solids direct releasesfinal-effluent flow meter and accredited laboratory analysistimestamp; sample_id; effluent_volume; parameter; concentration; method; detection_limitMatch each parameter concentration to the same discharge period and calculate its mass load.kgpermit monitoring frequency and each material changefull study periodfinal direct-discharge pointeffluent volume multiplied by temporally matched concentration for each parameterlaboratory accreditation; chain of custody; meter calibration; calculation review
cp_wwtp_air_releasesonsite_wastewater_treatmentammonia and hydrogen sulfide direct releasesairflow and concentration monitoring recordtimestamp; operating_state; exhaust_flow; substance; concentration; method; detection_limitMatch each substance concentration to treatment airflow and operating time.kgmonitoring campaign and each material changerepresentative treatment operation within study periodwastewater-treatment air-release pointsintegrate measured substance mass flow over applicable operating timelaboratory report; method; instrument calibration

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
calc_reference_normalizationall inventory rowsDivide the lot-attributed exchange by released net conforming frozen goat meat mass.lot-attributed exchange; released net reference-product massexchange per 1 kg reference producteu-2021-2279-environmental-footprint
calc_stage_electricityeach stage electricity rowUse a direct stage submeter; when a meter is shared, multiply the metered period total by an auditable equipment-activity or occupancy share.meter total; equipment activity or storage occupancy; lot release massstage electricity per reference floweu-2021-2279-environmental-footprint
calc_mass_balanceanimal, carcass, meat, co-product, and waste mass rowsReconcile measured mass entering each process with its separately recorded product and waste outputs; investigate rather than distribute unexplained imbalance.measured input masses; measured output masses; moisture or stock change recordsdocumented process mass balanceec-jrc-2024-sa-bref-jrc135916
calc_refrigerant_losseach refrigerant speciesFor each circuit and species, reconcile opening stock plus receipts against closing stock, recovered mass, and documented transfers; record the residual only when supported by service and leak evidence.opening stock; receipts; closing stock; recovered mass; transfers; service recordsspecies-specific refrigerant lossec-jrc-2024-sa-bref-jrc135916
calc_packaging_masseach packaging componentCalculate component use from issued mass less returned mass, or component count multiplied by verified unit mass; apply documented reuse cycles only to reusable pallets.issued mass; returned mass; component count; unit mass; reuse ledgercomponent mass per reference floweu-2021-2279-environmental-footprint
calc_thermal_energyeach purchased heat carrier and on-site fuelConvert measured carrier quantity to delivered energy using documented temperature, pressure, density, or heating-value records that match the reporting period.measured carrier quantity; carrier property recordsMJ per reference floweu-2021-2279-environmental-footprint
calc_combustion_releaseeach direct combustion substanceUse direct measured mass flow where available; otherwise apply a verified equipment-specific factor to measured fuel use and preserve the factor provenance.measured fuel; direct concentration and flow or verified factorsubstance mass to air per reference floweu-2021-2279-environmental-footprint
calc_wastewater_volumeeach wastewater streamUse a dedicated flow meter; when calculated, subtract only documented retained, product-bound, recovered, or evaporated water from the matched metered supply.stream meter or matched water balance recordsm3 wastewater per reference flowec-jrc-2024-sa-bref-jrc135916
calc_water_releaseeach direct water-release parameterMultiply measured final-effluent volume by a temporally matched measured concentration and convert units without substituting a concentration limit for a measured result.effluent volume; parameter concentration; unit conversionparameter mass to surface water per reference flowec-jrc-2024-sa-bref-jrc135916

Data Quality Requirements

requirement_idApplies toRequirementEvidence
dq_product_specificreference product and packagingUse product-specific net mass, BoM, release, and packaging records for the frozen-goat-meat product.approved product specification; BoM; signed lot release
dq_site_specificforeground manufacturingUse company-specific activity data and direct releases for processes operated by the reporting facility.meter, scale, ledger, laboratory, and service records
dq_temporalall foreground rowsCover a representative production period and disclose shutdowns, maintenance, seasonal storage, and missing intervals.coverage statement; gap register; operating calendar
dq_technologyfreezing, storage, thermal utility, and wastewater treatmentIdentify actual equipment, refrigerant species, heat route, and treatment configuration used during the study period.equipment register; piping diagram; service log; process-flow diagram
dq_mass_balanceanimal and meat conversionReconcile live-animal, carcass, meat, co-product, waste, and stock-change masses at lot or representative-period level.signed mass-balance worksheet and investigated residuals
dq_meter_reconciliationutilities and wastewaterReconcile submeter totals to facility meters and document every allocation driver used.meter hierarchy; calibration record; allocation worksheet
dq_destinationco-products and wastesRetain destination, legal status, and acceptance evidence so the same physical stream is not both a product and a waste.contract; dispatch ticket; inspection or acceptance record
dq_uuidall inventory identitiesUse a Tiangong UUID only after exact semantic hybrid search and public state=100 direct-read verification; keep the UUID absent while unresolved.dual-verification evidence or manifest unresolved entry
dq_uncertaintyall inventory rowsDocument measurement resolution, calibration, missing-data treatment, factor provenance, and allocation uncertainty without inventing a category range.uncertainty register and calculation review
dq_completenessfull inventoryDemonstrate coverage of material, energy, waste, and direct air and water exchanges inside the boundary.process-flow diagram; row checklist; input-output reconciliation

9. Validation Rules

rule_idApplies toRulesource_ids
validate_reference_uuidreference flowRequire Product flow cf1026b3-d517-4896-b54b-0ba4e919a40b, Mass 93a60a56-a3c8-11da-a746-0800200b9a66, Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66, and kg.un-cpc-3-0-structure-2025
validate_reference_amountreference outputRequire exactly 1 kg net conforming frozen goat meat and exclude packaging mass.un-cpc-3-0-structure-2025
validate_scopeproduct identityReject fresh or chilled goat meat, edible offal as the reference product, and any non-goat meat.un-cpc-3-0-structure-2025
validate_boundaryprocess coverageRequire every mandatory process and require a documented inclusion decision for on-site wastewater treatment.ec-jrc-2024-sa-bref-jrc135916
validate_atomicinventory rowsRequire one specific physical or chemical exchange per row_id and a nonempty description, amount rule, protocol, uncertainty statement, applicability statement, and source list.ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint
validate_selector_freeselected flowsReject collection labels or instructions in Selected flow; utilities, fuels, refrigerants, chemicals, packaging components, wastes, and releases must remain separate.eu-2021-2279-environmental-footprint
validate_uuidinventory UUIDsAccept a non-reference UUID only after exact semantic flow-hybrid-search and public state=100 direct-read verification; otherwise require no UUID.eu-2021-2279-environmental-footprint
validate_manifest_closureunresolved UUIDsRequire every UUID-free row_id to appear once in manifest review_metadata with its candidate identity and rejection reason.eu-2021-2279-environmental-footprint
validate_value_modeinventory amountsAllow foreground_record or calculated_value supported by collected records; reject unsupported authored quantities and category default ranges.eu-2021-2279-environmental-footprint
validate_mass_balancephysical outputsReconcile accepted live mass, carcass, meat, co-products, condemned streams, contents, wastewater-associated solids, and stock change without forced balancing.ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint
validate_heat_routesthermal inputsPrevent duplicate recording of purchased steam, purchased hot water, and on-site fuel used to generate the same heat.eu-2021-2279-environmental-footprint
validate_refrigerantscold systemIdentify each actual refrigerant by species and circuit; require its own make-up and direct-release row when a loss occurs.ec-jrc-2024-sa-bref-jrc135916
validate_cleaning_agentscleaningIdentify each cleaning or disinfection substance separately from stock and dosing records; add a new atomic row for every additional substance used.ec-jrc-2024-sa-bref-jrc135916
validate_packagingpackagingMatch each actual packaging component and its material-specific waste to the product BoM and exclude packaging mass from the reference product.eu-2021-2279-environmental-footprint
validate_destinationsco-products and wastesRequire destination and status evidence and prohibit assigning one physical quantity to both a co-product row and a waste row.ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint
validate_wastewaterwastewaterKeep routine and high-organic-load wastewater separate; distinguish sewer transfer from direct surface-water discharge and on-site treatment.ec-jrc-2024-sa-bref-jrc135916
validate_air_releasesdirect air releasesRequire substance-specific measured or calculated releases and factor provenance; do not report an aggregate combustion or refrigerant release row.ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint
validate_water_releasesdirect water releasesFor direct discharge, require temporally matched effluent volume and parameter concentration for each release row.ec-jrc-2024-sa-bref-jrc135916
validate_sourcesevidenceUse only the listed UN CPC, EC JRC SA BREF, and Commission Recommendation sources for this PCR; do not treat UUID lookup as amount evidence.un-cpc-3-0-structure-2025; ec-jrc-2024-sa-bref-jrc135916; eu-2021-2279-environmental-footprint
validate_bilingualbilingual recordRequire identical ordered process_id, direction, flow_type, row_id, UUID, controlled tokens, protocol ids, and source-id sequences in en-US and zh-CN.eu-2021-2279-environmental-footprint

10. Published Dataset Profile

FieldValue
dataset_roleFacility-specific foreground data package for CPC 21136 frozen goat meat
downstream_useConstruction and validation of TianGong flow, process, lifecyclemodel, and dataset projections
allowed_useProduct-specific modelling when the facility boundary, reference qualifiers, actual technology, and collection period are disclosed
excluded_useCategory-default inventory; fresh or chilled goat meat; edible-offal reference product; retail or meal modelling
required_metadataFacility geography; reporting period; production volume; lot definition; net-mass method; slaughter and cutting configuration; freezing technology; frozen-storage duration; heat route; refrigerant species; packaging BoM; co-product and waste destinations; wastewater route
required_quality_disclosureMeter and scale calibration; temporal coverage; missing data; calculation inputs; allocation decisions; mass balance; uncertainty; UUID status
update_triggerChange in product scope, slaughter or cutting configuration, freezing or storage technology, energy route, refrigerant species, packaging BoM, co-product destination, wastewater route, or evidence source

11. Data Sources

source_idtypereferenceused_for
un-cpc-3-0-structure-2025Dataset (dataset)United Nations Statistics Division, CPC Ver. 3.0 official page, https://unstats.un.org/unsd/classifications/Econ/CPC; retained raw structure classifications/systems/cpc/3.0/raw/CPC_Ver_3.0_Structure_30Jun2025.csvExact CPC 21136 identity and frozen-state boundary; exclusion of CPC 21116 fresh or chilled goat meat and CPC 21156 edible goat offal
ec-jrc-2024-sa-bref-jrc135916Official guidance (official_guidance)European Commission Joint Research Centre, Best Available Techniques Reference Document for the Slaughterhouses, Animal By-products and/or Edible Co-products Industries, JRC135916, 2024, DOI 10.2760/18199, https://publications.jrc.ec.europa.eu/repository/handle/JRC135916Slaughter boundary through standard cuts; process decomposition; cooling and freezing; cleaning; utilities; refrigerants; separately managed animal outputs; wastewater; sludge; direct air and water releases
eu-2021-2279-environmental-footprintOfficial guidance (official_guidance)Commission Recommendation (EU) 2021/2279, consolidated 30 December 2021, https://eur-lex.europa.eu/eli/reco/2021/2279/2021-12-30/engProduct-specific BoM and manufacturing data; complete LCI of material, energy, product, waste, and direct releases; allocation hierarchy; completeness, transparency, data quality, and verification

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.