Thermally toughened flat monolithic soda-lime safety glass · 11. Data Sources
- Lifecycle status
- Candidate
- Content maturity
- Authored methodology
- Current version
- 0.1.0Last updated
- Readiness
- Review required
Methodology and translation states come from the source record; publishing this website does not change their review status.
Content languages
zh-CN · Aligned
Status, classification and source details
Readiness
- Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.
Classification mapping
CPC 3.0:37115 · narrower
Source
11. Data Sources
| Source id | Type | Reference | Used for |
|---|---|---|---|
| pilkington-toughened-glass | handbook | https://www.pilkington.com/en-gb/united-kingdom/architectural-and-technical-glass/product-categories/safety-and-security/pilkington-toughened-glass | Primary manufacturer product description and explicit heat-strengthened counterexample; thermal safety-glass terminal and pre-toughening fabrication; no numeric performance or conformity default |
| gpd-tempering-control-2023 | literature | Aronen A.; Kelin S.; Lyytikäinen P. How to change the tempering process control from settings to specifications. GPD 2023 pp.268–270. https://gpd.fi/wp-content/uploads/2022/09/78-Antti-Aronen-How-to-change-the-tempering-process-control.pdf | Primary technical paper; electric roller-furnace heating and air quench; Figure1 heat/cool stages; Figures2–3 quality/process dependence and schematic limits; no temperature energy yield or strength default |
| landglass-wash-dry-2020 | handbook | LandGlass. Why the glass sheets must be washed and dried before tempering? 2020-11-05. https://www.landglass.net/FAQ/questioninfo/463.html | Primary equipment-maker explanation of residue removal and dry surface before toughening; no detergent formulation water or energy quantity default |
| bavelloni-ve-edgers | handbook | Bavelloni. VE Series straight-line edging machines. https://www.bavelloni.com/wp-content/uploads/2016/03/VERTICAL-EDGERS-VE-SERIES-ITA-ENG.pdf | Primary equipment brochure and page11 tools configuration; wheel wear and adjacent polishing alternatives; neither a complete safety-glass route nor a same-factory quantity recipe |
| glaston-fc-flat-tempering | handbook | Glaston. FC Series X. https://glaston.net/machine/fc-series/ | Primary commercial evidence of flat-glass convection tempering equipment and actual flat-tempered product route; marketing energy/yield claims not adopted as values or certification |
| ilcd-attributional-2010 | official_guidance | European Commission JRC. ILCD Handbook General guide for LCA — Detailed guidance. First edition March2010 §§7.9.2–7.9.3 pp.255–268. https://eplca.jrc.ec.europa.eu/uploads/ILCD-Handbook-General-guide-for-LCA-DETAILED-GUIDANCE-12March2010-ISBN-fin-v1.0-EN.pdf | Attributional subdivision and virtual subdivision; exchange-specific determining physical causality; only genuinely residual common-process-gate contemporaneous actual-state market value; no arbitrary fixed shares or automatic credit |
Raw downloads
These files are byte-identical to the canonical files for this revision in the repository.
Complete field inspector