TianGong PCR产品类别规则

Solid-state non-volatile storage devices

Solid-state non-volatile storage devices: This PCR supports foreground data packages for finished solid-state non-volatile storage devices supplied at the manufacturing…

Lifecycle status
Candidate
Content maturity
Authored methodology
Current version
No published version
Readiness
Review required
Last updated

Methodology and translation states come from the source record; publishing this website does not change their review status.

Content languages

zh-CN · Aligned
Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:47550 · exact

Source

1. Scope and Applicability

This PCR supports foreground data packages for finished solid-state non-volatile storage devices supplied at the manufacturing gate. It covers devices and solid-state media that retain data without power and are delivered with the physical integration needed to record data from an external source, including generic client, enterprise, embedded, card, and comparable finished embodiments within CPC 3.0 code 47550.

The category includes finished solid-state drives, flash memory cards or flash electronic storage cards, and functionally equivalent finished solid-state non-volatile storage products. A concrete data package must identify its actual architecture and must not claim that a single capacity, interface, form factor, memory-cell technology, or application class represents the whole category.

This PCR excludes bare NAND dies or wafers, unpackaged or separately traded memory/controller integrated circuits, semiconductor fabrication intermediates, magnetic or optical recording media, hard disk drives, removable-media drives and readers, smart cards, complete data-centre storage systems, host computers, and software or recorded content. Those products require their own product identity and upstream or downstream datasets. The distinction between an included flash memory card and an excluded removable-media storage unit is that the former is the solid-state recording medium/device itself, while the latter is a reader or drive designed to accept removable media. Category interpretation follows the UN CPC explanatory notes. [unsd-cpc-3-0-2025]

The default data-production boundary is cradle-to-manufacturing-gate at the aggregate dataset level. Foreground collection begins with accepted purchased components and materials at the reporting site and ends with packaged conforming product at the site gate. Upstream production of NAND, controllers, other integrated circuits, printed circuit boards, substrates, connectors, enclosures, joining materials, and packaging remains in the product system through supplier-specific or representative background datasets even when it is outside the assembler's direct foreground control.

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.metal-products-machinery-and-equipment.radio-television-and-communication-equipment-and-apparatus.solid-state-non-volatile-storage-devices
classification_refsCPC 3.0: 47550, Solid-state non-volatile storage devices (exact scope reference)
covered_productsFinished solid-state non-volatile storage devices or media that record externally supplied data; generic SSD, flash memory card, flash electronic storage card, and equivalent finished embodiments
excluded_productsBare NAND or controller dies/wafers/chips; semiconductor intermediates; HDDs; magnetic or optical media; removable-media readers/drives; smart cards; complete storage arrays or host computers; software or recorded content; capacity-, model-, material-, route-, or application-specific flows used as a generic category reference
representative_productA mass-weighted declared production mix of conforming finished devices at the manufacturing gate, with capacity, interface/protocol, form factor, media technology, firmware state, application class, enclosure and packaging state disclosed
production_routePurchased-component receipt and reconciliation; electronic/media interconnection and device assembly; firmware/configuration programming; functional test and yield control; final packaging; allocated site utilities and waste management
market_stateFinished, quality-released, unrecorded or factory-initialized product at the manufacturing gate; not a bare component and not a host system

3. Reference Flow

FieldValue
WhatDelivery of finished solid-state non-volatile storage devices able to record data from an external source
How much1 kg net mass of conforming finished product at the manufacturing gate, excluding transport packaging unless the declared dataset intentionally includes it and reports its mass separately
How wellProduct identity and CPC 47550 scope are satisfied; user capacity, interface/protocol and speed class, form factor, non-volatile media type/technology, firmware revision or configuration state, client/enterprise/embedded/card application class, enclosure state, and packaging state are declared
How long or cycleOne declared production lot or reporting period at the manufacturing gate; service life and use-stage workload are not represented by the mass reference and must be modelled separately when relevant
reference_flow_link1 kg of Solid-state non-volatile storage devices 4c208ec5-5d80-4547-ab8e-347ef5fb1caf
FieldValue
Reference amount1 kg
Reference product flowSolid-state non-volatile storage devices 4c208ec5-5d80-4547-ab8e-347ef5fb1caf
Reference flow propertyMass 93a60a56-a3c8-11da-a746-0800200b9a66
Reference unit groupUnits of mass 93a60a57-a4c8-11da-a746-0800200c9a66
Reference unitkg
Required qualifiersuser capacity and capacity convention; interface/protocol and rated speed; form factor and dimensions; non-volatile media type and memory-cell technology where known; controller and firmware/configuration state; client, enterprise, embedded, card, or other application class; enclosure and connector state; factory-recorded content or initialization state; production geography and reporting period; product and included-packaging masses; production-mix or single-product basis

When constructing a foreground data package, the items listed in Required qualifiers must be declared in dataset metadata, process notes, reference flow comment, product description, or an equivalent data package field. Missing required qualifiers make the reference flow definition incomplete for that data package. SNIA device-level reporting identifies user capacity, interface/speed, form factor, media type, firmware revision, and intended client or enterprise context as material descriptors; the same descriptors are therefore retained here without prescribing a particular performance level. [snia-sss-pts-2-0-2]

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
reference_product_massReference productMass 93a60a56-a3c8-11da-a746-0800200b9a66kgWeigh or otherwise reconcile the net mass of conforming finished devices. Exclude transport packaging from the 1 kg reference amount and report included primary or retail packaging separately unless the declared product flow explicitly includes it.
capacity_is_qualifierUser capacityDeclared digital storage capacityGB or TB with decimal/binary convention statedCapacity is a required product qualifier and calculation driver, not a substitute for the mass reference flow. Do not convert a capacity-specific result to another capacity without product-specific bill-of-materials, yield, and energy evidence. [snia-sss-pts-2-0-2]
energy_measurementElectricity and fuel inputsEnergykWh, MJ, or source meter unit with documented conversionPreserve source meter units and conversion factors. Separate directly metered process energy from allocated shared-facility energy and prevent double counting.
water_and_gas_measurementWater and process gas inputsMass or volume at declared conditionskg, m3, Nm3, or source meter unitState temperature/pressure convention for gaseous volumes and density/conversion basis where mass and volume are converted.
lot_to_reference_normalizationAll foreground amountsQuantity appropriate to each flowRow-specific unit per 1 kg reference productNormalize only after reconciling the same reporting period's conforming net product mass, rejects, rework, and inventory changes.

5. System Boundary

rule_idApplies toRulesource_ids
boundary_finished_device_gateForeground manufacturingInclude component receipt and reconciliation, assembly/interconnection, programming or configuration, functional testing and yield disposition, finished-product packaging, and the allocated share of site utilities, abatement, wastewater and waste management needed to deliver conforming finished product at the manufacturing gate.eu-pef-method-2021; samsung-semiconductor-lca-method
boundary_upstream_component_coveragePurchased components and materialsNAND packages, controller and support ICs, substrates/PCBs, connectors, enclosures, joining materials, consumables, utilities, and packaging must retain upstream production through supplier-specific or representative datasets. Do not cut off semiconductor components because their physical mass is small.eu-pef-method-2021; boyd-horvath-dornfeld-nand-lca-2011
boundary_foreground_controlVertically integrated productionWhen wafer fabrication, IC packaging, PCB/substrate manufacture, connector manufacture, or enclosure manufacture is under the reporting organisation's direct control, collect it as additional foreground processes or attach disaggregated site datasets; otherwise use reviewed upstream datasets and disclose the boundary.eu-pef-method-2021; samsung-semiconductor-lca-method
boundary_use_and_end_of_lifeDownstream stagesDistribution, use-phase electricity, maintenance, service-life extension, data erasure, reuse and end-of-life are outside this manufacturing-gate foreground package unless explicitly added as separate downstream modules. A mass-based dataset alone must not support comparative storage-service claims.eu-pef-method-2021; boyd-horvath-dornfeld-nand-lca-2011
boundary_no_unreported_cutoffCompletenessReport all known material, energy, water, process-gas, waste and direct-emission flows. Any unavailable quantity remains a documented data gap; it is not silently treated as zero.eu-pef-method-2021

Boundary Abstraction

FieldValue
declared_starting_conditionAccepted purchased components, materials and consumables at the reporting site's receiving point, with opening inventories and upstream dataset links declared
starting_condition_roleForeground assembly-gate input condition for producing a cradle-to-manufacturing-gate aggregate data package
product_classification_scopeFinished solid-state non-volatile storage devices within CPC 3.0 code 47550; included flash cards are the recording device/media itself, not an external reader or drive
recursive_input_ruleIf an input is itself a finished product in this same category, record its quantity once as a product input and link a separate upstream dataset; do not recursively expand the same PCR within the current foreground process
upstream_dataset_requirementEvery purchased semiconductor, electronic, structural, joining, utility and packaging input requires a supplier-specific or representative upstream dataset with geography, technology and time representativeness disclosed
disclosureDeclare ownership boundary, included sites and processes, outsourced operations, product-mix basis, component technology, capacity mix, yield/rework treatment, electricity geography and period, allocation drivers, packaging treatment, and any unresolved quantity or upstream dataset gap

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
device_assembly_and_programmingDevice assembly and programmingrequiredAlways included for a finished device; adapt the interconnection step to card, module, board, packaged-drive, or equivalent architectureForeground productionNet assembled device mass transferred to testing and all associated input, scrap and direct-emission records
functional_test_and_yield_controlFunctional test and yield controlrequiredAlways included; test protocol and conditioning intensity reflect declared product/application classForeground conditioning and quality releaseConforming unpackaged device mass and reconciled rejected/reworked device mass
finished_product_packagingFinished-product packagingrequiredAlways included; zero or reusable packaging must be explicitly demonstratedForeground finalizationPackaged output corresponding to 1 kg net finished device plus separately reported packaging mass
site_support_and_waste_managementSite support and waste managementrequiredInclude only shared burdens not already directly metered to the other processesForeground supportCausally allocated share per 1 kg net finished reference product

Process: Device assembly and programming (device_assembly_and_programming)

Inputs

Product flows
Purchased non-volatile memory components (purchased_nvm_components)

Record all NAND packages, other non-volatile memory packages, stacked packages, or finished memory modules incorporated into the device. Bare wafer or die fabrication is an upstream product system unless it is explicitly brought into the foreground boundary.

  • Selected flow: Purchased non-volatile memory components, resolved by actual component identity before publication
  • Flow property / unit: Mass / kg
  • Amount rule: supplier receipt and bill-of-materials mass reconciled to components issued to the production lot
  • Value mode: Calculated value (calculated_value)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg net finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_bom_component_and_material_records
  • Sources: boyd-horvath-dornfeld-nand-lca-2011; samsung-semiconductor-lca-method
Controllers and support electronics (controller_and_support_electronics)

Record controller ICs, power-management ICs, passive components, security or bridge devices and other populated electronics incorporated into the product.

  • Selected flow: Controller and support electronic components, resolved by actual component identity before publication
  • Flow property / unit: Mass / kg
  • Amount rule: bill-of-materials quantity multiplied by verified component mass, reconciled to issued and returned components
  • Value mode: Calculated value (calculated_value)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg net finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_bom_component_and_material_records
  • Sources: samsung-semiconductor-lca-method
Interconnect and structural components (interconnect_and_structural_components)

Record the PCB or substrate, connector, enclosure, heat spreader, labels and other permanent structural parts of the finished device.

  • Selected flow: Interconnect and structural components, one reviewed flow per material/component class
  • Flow property / unit: Mass / kg
  • Amount rule: bill-of-materials and receipt mass, corrected for opening/closing inventories and production returns
  • Value mode: Calculated value (calculated_value)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg net finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_bom_component_and_material_records
  • Sources: eu-pef-method-2021
Joining and assembly materials (joining_and_assembly_materials)

Record solder, adhesives, underfill, encapsulants, coatings, cleaning agents and other materials consumed by assembly.

  • Selected flow: Joining and assembly materials, one reviewed flow per substance or formulated product
  • Flow property / unit: Mass / kg
  • Amount rule: purchase/issue records or line dispensing records less documented returns, normalized to conforming output
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_bom_component_and_material_records
  • Sources: eu-pef-method-2021
Assembly-line electricity (assembly_line_electricity)

Record electricity directly metered or causally assigned to placement, joining, curing, cleaning, programming and related line equipment.

  • Selected flow: Electricity supply matching the site, period and voltage level
  • Flow property / unit: Energy / kWh
  • Amount rule: sub-metered electricity or equipment power-time records for the reporting period, excluding shared electricity recorded under site support
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_process_energy_records
  • Sources: eu-pef-method-2021; samsung-semiconductor-lca-method
Waste flows

Outputs

Product flows
Assembled and programmed device transferred to testing (assembled_programmed_device)

Record the mass transferred to functional testing, including work in progress carried across the reporting-period boundary.

  • Selected flow: Assembled solid-state storage device before final test
  • Flow property / unit: Mass / kg
  • Amount rule: measured transfer mass plus closing work in progress minus opening work in progress
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_mass_yield_rework_and_waste_records
  • Sources: eu-pef-method-2021
Waste flows
Assembly scrap and material losses (assembly_scrap_and_losses)

Record rejected components, board/substrate scrap, solder dross, spent assembly materials and other externally treated assembly wastes separately by treatment route.

  • Selected flow: Assembly waste, one reviewed waste flow per waste class and treatment route
  • Flow property / unit: Mass / kg
  • Amount rule: weighbridge, hazardous-waste manifest, scrap sale, or production reject record; subtract only documented internal reuse returned within the boundary
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_mass_yield_rework_and_waste_records
  • Sources: eu-pef-method-2021
Elementary flows
Direct assembly emissions (assembly_direct_emissions)

Record each measured or permitted direct release from cleaning, joining, curing or coating as a separate elementary flow; do not duplicate releases already contained in upstream electricity or material datasets.

  • Selected flow: Site-specific elementary emission to air, water or soil, resolved substance by substance
  • Flow property / unit: Mass / kg
  • Amount rule: stack/effluent measurement, mass balance or regulated release record attributable to assembly
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_site_emission_and_discharge_records
  • Sources: eu-pef-method-2021

Process: Functional test and yield control (functional_test_and_yield_control)

Inputs

Product flows
Assembled devices entering test (assembled_devices_entering_test)

Record mass and unit count entering test, including opening and closing work in progress.

  • Selected flow: Assembled solid-state storage device before final test
  • Flow property / unit: Mass / kg
  • Amount rule: production execution records reconciled to transferred mass and unit count
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_mass_yield_rework_and_waste_records
  • Sources: snia-sss-pts-2-0-2
Test and conditioning electricity (test_and_conditioning_electricity)

Record electricity for functional test, data-write/read conditioning, burn-in where applied, thermal control and test-support equipment. The test state, workload and duration must match the declared product class.

  • Selected flow: Electricity supply matching the site, period and voltage level
  • Flow property / unit: Energy / kWh
  • Amount rule: test-cell sub-metering or tester power-time records linked to tested units and test recipes
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg net finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_test_recipe_energy_and_result_records
  • Sources: snia-sss-pts-2-0-2
Test consumables and replacements (test_consumables_and_replacements)

Record sockets, fixtures, thermal-interface materials, cleaning materials and other consumables when consumed or replaced during the reporting period.

  • Selected flow: Test consumables, one reviewed flow per material or component class
  • Flow property / unit: Mass / kg or item count converted with measured item mass
  • Amount rule: issue and replacement records allocated by tested units, tester-hours or another causal driver
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_test_recipe_energy_and_result_records
  • Sources: eu-pef-method-2021

Outputs

Product flows
Conforming unpackaged devices (conforming_unpacked_devices)

Record only quality-released finished devices. Preserve capacity, interface, form factor, media type, firmware and application-class distribution for mixed production.

  • Selected flow: Solid-state non-volatile storage devices 4c208ec5-5d80-4547-ab8e-347ef5fb1caf
  • Flow property / unit: Mass / kg
  • Amount rule: quality-release unit count multiplied by measured product mass and reconciled to shipment/packaging transfer records
  • Value mode: Calculated value (calculated_value)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg net finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_finished_product_mass_and_qualifiers
  • Sources: unsd-cpc-3-0-2025; snia-sss-pts-2-0-2
Waste flows
Failed devices and test waste (failed_devices_and_test_waste)

Record failed devices, replaced parts and spent test consumables by final disposition. Reworked devices returned within the boundary are not external waste but must remain in the yield reconciliation.

  • Selected flow: Failed electronic device and test waste, one reviewed waste flow per final disposition
  • Flow property / unit: Mass / kg
  • Amount rule: failure-analysis and disposition records reconciled to tested, reworked, released and scrapped unit counts
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_mass_yield_rework_and_waste_records
  • Sources: eu-pef-method-2021
Elementary flows
Direct test emissions (test_direct_emissions)

Record direct releases from test or conditioning only when they occur; use separate elementary flows by substance and receiving compartment.

  • Selected flow: Site-specific elementary emission to air, water or soil, resolved substance by substance
  • Flow property / unit: Mass / kg
  • Amount rule: measured or calculated release attributable to the test process
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_site_emission_and_discharge_records
  • Sources: eu-pef-method-2021

Process: Finished-product packaging (finished_product_packaging)

Inputs

Product flows
Conforming devices entering packaging (devices_entering_packaging)

Record the net mass of conforming devices transferred into packaging.

  • Selected flow: Solid-state non-volatile storage devices 4c208ec5-5d80-4547-ab8e-347ef5fb1caf
  • Flow property / unit: Mass / kg
  • Amount rule: packaging transfer records reconciled to quality-release and shipment records
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_finished_product_mass_and_qualifiers
  • Sources: unsd-cpc-3-0-2025
Primary, secondary and transport packaging (packaging_material_inputs)

Record bags, trays, reels, cards, boxes, cushioning, labels, desiccants and pallets separately by material and packaging level. Reusable packaging must include trips, losses and return logistics in its separate upstream model.

  • Selected flow: Packaging material, one reviewed flow per material and packaging level
  • Flow property / unit: Mass / kg
  • Amount rule: packaging bill of materials and purchase/issue records reconciled to packed units and packaging waste
  • Value mode: Calculated value (calculated_value)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg net finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_packaging_material_energy_and_waste_records
  • Sources: eu-pef-method-2021
Packaging-line electricity (packaging_line_electricity)

Record directly metered or causally allocated electricity for packaging equipment, excluding shared electricity recorded under site support.

  • Selected flow: Electricity supply matching the site, period and voltage level
  • Flow property / unit: Energy / kWh
  • Amount rule: packaging-line meter or equipment power-time records for the reporting period
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_packaging_material_energy_and_waste_records
  • Sources: eu-pef-method-2021

Outputs

Product flows
Packaged finished reference product (packaged_finished_reference_product)

The reference output is 1 kg net finished device. Packaging mass is reported as a separate input and metadata value so that studies can include or exclude packaging consistently.

  • Selected flow: Solid-state non-volatile storage devices 4c208ec5-5d80-4547-ab8e-347ef5fb1caf
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: fixed reference amount of 1 kg net conforming device mass
  • Value mode: Fixed value (fixed_value)
  • Specificity: Generic (generic)
  • Normalization basis: 1 kg net finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Identity reference (identity_reference)
  • Sources:
Waste flows
Packaging waste (packaging_waste)

Record damaged, trimmed or unused packaging leaving the site by material and treatment route.

  • Selected flow: Packaging waste, one reviewed waste flow per material and treatment route
  • Flow property / unit: Mass / kg
  • Amount rule: waste weighing or packaging material balance for the reporting period
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_packaging_material_energy_and_waste_records
  • Sources: eu-pef-method-2021
Elementary flows
Direct packaging emissions (packaging_direct_emissions)

Record direct packaging-line releases only when present, as separate elementary flows by substance and receiving compartment.

  • Selected flow: Site-specific elementary emission to air, water or soil, resolved substance by substance
  • Flow property / unit: Mass / kg
  • Amount rule: measured or calculated release attributable to packaging
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_site_emission_and_discharge_records
  • Sources: eu-pef-method-2021

Process: Site support and waste management (site_support_and_waste_management)

Inputs

Product flows
Shared site energy and fuels (shared_site_energy_and_fuels)

Record electricity and fuels for HVAC, dry air, compressed air, vacuum, lighting, offices and other shared services only to the extent not already directly metered to a production process.

  • Selected flow: Site- and period-specific electricity and fuel supplies, one reviewed flow per supply
  • Flow property / unit: Energy / kWh or MJ
  • Amount rule: site meter totals minus directly assigned process consumption, allocated with documented causal drivers
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_shared_site_utility_records
  • Sources: eu-pef-method-2021; samsung-semiconductor-lca-method
Shared water and process gases (shared_water_and_process_gases)

Record shared water, nitrogen and other process gases not captured by direct line records. Semiconductor-fabrication gases belong in the supplier or vertically integrated fabrication dataset, not as unsupported assembly estimates.

  • Selected flow: Water and process-gas supplies, one reviewed flow per supply
  • Flow property / unit: Mass or volume / kg, m3 or Nm3 with conditions declared
  • Amount rule: site meter and purchase records minus directly assigned consumption, allocated with documented causal drivers
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_shared_site_utility_records
  • Sources: boyd-horvath-dornfeld-nand-lca-2011; samsung-semiconductor-lca-method

Outputs

Product flows
Waste flows
Shared wastewater and solid waste (shared_wastewater_and_solid_waste)

Record shared wastewater and site wastes not already assigned to a production process, separated by composition where known and final treatment route.

  • Selected flow: Wastewater or solid waste, one reviewed waste flow per waste class and treatment route
  • Flow property / unit: Mass or volume / kg or m3
  • Amount rule: discharge meters, waste manifests and treatment invoices minus directly assigned process wastes
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_shared_site_utility_records
  • Sources: eu-pef-method-2021
Elementary flows
Shared direct site emissions (shared_direct_site_emissions)

Record each remaining direct air, water or soil emission after subtracting releases already assigned to production processes. Preserve substance and receiving-compartment identity.

  • Selected flow: Site-specific elementary emission to air, water or soil, resolved substance by substance
  • Flow property / unit: Mass / kg
  • Amount rule: site monitoring or regulated release total minus directly assigned releases, allocated with the same causal drivers as the associated support activity
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_site_emission_and_discharge_records
  • Sources: eu-pef-method-2021

7. Allocation and Co-product Handling

rule_idApplies toRulesource_ids
allocation_avoid_by_subdivisionMulti-product lines and shared processesFirst avoid allocation by sub-metering, separate production orders, process subdivision, or a documented physical expansion of the measured system.eu-pef-method-2021
allocation_physical_driverShared site utilities, consumables and wastesWhen subdivision is not feasible, use a causal physical driver such as measured equipment energy, machine-hours, test-hours, occupied area with time, material throughput, or net product mass. Explain why the driver represents resource use; do not default to revenue.eu-pef-method-2021
allocation_product_mixMultiple capacities, form factors or technologiesRetain product-specific BOM, mass, test recipe, yield and energy records where available. A production-mix dataset must be mass-weighted or production-weighted from disclosed product-specific records; do not scale solely by capacity.eu-pef-method-2021; snia-sss-pts-2-0-2
allocation_rework_and_internal_recyclingRework and internally returned materialKeep reworked units and internally returned material inside the foreground boundary. Count only net external inputs, conforming outputs and externally transferred wastes, while retaining gross yield and rework records for audit.eu-pef-method-2021
allocation_recovered_materialScrap sold or sent for recoveryRecord the outgoing waste/material quantity and treatment route without an unreviewed avoided-burden credit in the foreground manufacturing dataset. Apply recycling or end-of-life credits only in a declared downstream method that is consistent across compared systems.eu-pef-method-2021

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_bom_component_and_material_recordsdevice_assembly_and_programmingpurchased_nvm_components; controller_and_support_electronics; interconnect_and_structural_components; joining_and_assembly_materialsBOM, purchase receipt, material issue/return and inventory recordproduct/SKU; supplier; component/material identity; quantity; unit mass; lot; issue; return; opening/closing inventory; scrap linkExport controlled BOM and ERP/MES records; verify representative unit masses by weighing or supplier declarationkg and itemEach production lot with monthly reconciliationSame representative reporting period as outputAll included manufacturing sites and outsourced assembly under operational controlReconcile issued plus opening inventory minus returns and closing inventory to incorporated material and recorded loss, then normalize to conforming net product massApproved BOM revision, supplier specification, calibration record, ERP/MES extract and reconciliation sign-off
cp_process_energy_recordsdevice_assembly_and_programmingassembly_line_electricitySub-meter, equipment runtime and power recordmeter id; start/end reading; interval; equipment; recipe; runtime; tested/assembled units; voltage levelPrefer calibrated sub-metering; otherwise use measured power by operating state multiplied by logged runtimekWhContinuous or per lot; reconcile monthlyAt least 12 representative months or justified production campaignEach included assembly line/siteSum direct process energy and divide by same-period conforming net product mass; exclude energy captured as shared supportMeter calibration, raw interval export, equipment log and no-double-count reconciliation
cp_mass_yield_rework_and_waste_recordsdevice_assembly_and_programming; functional_test_and_yield_controlassembled_programmed_device; assembly_scrap_and_losses; assembled_devices_entering_test; failed_devices_and_test_wasteMES transfer, yield, rework, scrap and waste disposition recordinput units/mass; good units/mass; rework loops; WIP change; reject code; waste mass; disposition; treatment routeReconcile production orders, weigh representative products and wastes, and link external waste documentskg and itemEach lot; monthly closureSame reporting period as material and energy recordsAll included production and test operationsgood output + external waste + closing WIP - opening WIP must reconcile with input and documented inventory changes within stated toleranceScales calibration, MES audit trail, failure analysis, waste manifest and signed mass-balance review
cp_test_recipe_energy_and_result_recordsfunctional_test_and_yield_controltest_and_conditioning_electricity; test_consumables_and_replacementsTest recipe, tester log, power record, consumable issue and result recorddevice class; capacity; interface; firmware; media type; recipe; workload; test duration; power/energy; pass/fail/rework; consumablesLink tester and power data to serial/lot results and actual test recipe; retain deviations from standard settingskWh, kg, item and hEach tested lot or statistically complete automated logSame representative reporting period as outputEach included test cell/siteAggregate energy and consumables by actual tested population, preserving product/application class before normalizing to conforming massTest-system calibration, immutable recipe/version, SNIA-compatible descriptors where applicable, and traceable pass/fail log
cp_finished_product_mass_and_qualifiersfunctional_test_and_yield_control; finished_product_packagingconforming_unpacked_devices; devices_entering_packaging; packaged_finished_reference_productQuality release, product master, measured mass and shipment transfer recordSKU; capacity convention; interface/protocol; speed; form factor; media type; firmware; application class; enclosure; unit mass; released units; packaging stateExport released population and product master; weigh a documented representative sample for each product familykg and itemEach released lot; product mass rechecked after design changeSame reporting period as inventoryAll products/sites included in datasetCalculate net finished mass by qualified product family; production-mix aggregation preserves weights and qualifiersCalibrated scale, sampling record, product specification, quality release and shipment reconciliation
cp_packaging_material_energy_and_waste_recordsfinished_product_packagingpackaging_material_inputs; packaging_line_electricity; packaging_wastePackaging BOM, issue, meter and waste recordpackaging level; material; unit mass; issued/returned quantity; packed units; meter readings; waste mass; reuse cycles/lossesReconcile packaging BOM and purchases to packed output and waste; meter packaging energy where materialkg, item and kWhEach lot with monthly reconciliationSame reporting period as packaged outputEach included packaging locationReport packaging separately by material and level; allocate reusable packaging over evidenced trips and lossesPackaging specification, supplier declaration, scale/meter calibration, reuse log and mass balance
cp_shared_site_utility_recordssite_support_and_waste_managementshared_site_energy_and_fuels; shared_water_and_process_gases; shared_wastewater_and_solid_wasteSite meter, invoice, tank/purchase and waste recordutility/fuel identity; meter; interval; quantity; directly assigned subtraction; site output; allocation driver; waste class/routeCollect site totals, subtract direct process records, and allocate residual with a documented causal driverkWh, MJ, kg, m3 or Nm3MonthlyAt least 12 representative months or justified campaignEach included siteResidual shared total is allocated once; all direct and shared amounts reconcile to the site totalInvoice/meter agreement, calibration, allocation worksheet, waste manifest and management approval
cp_site_emission_and_discharge_recordsdevice_assembly_and_programming; functional_test_and_yield_control; finished_product_packaging; site_support_and_waste_managementassembly_direct_emissions; test_direct_emissions; packaging_direct_emissions; shared_direct_site_emissionsStack, effluent, permit, laboratory and mass-balance recordsubstance; compartment; source; concentration; flow; duration; abatement; uncertainty; direct-process assignmentUse measured releases where available; otherwise use a documented mass balance or regulated method and identify estimation basiskg per substancePer monitoring plan with reporting-period reconciliationSame representative reporting period as outputAll included emission points and discharge routesSum direct-process and residual shared releases once, normalized to conforming net product massAccredited laboratory result, calibrated monitor, permit report, abatement log and calculation audit trail
cp_supplier_upstream_coveragedevice_assembly_and_programmingall purchased component, material, utility and packaging inputsSupplier PCF/LCI, verified EPD, process dataset or background dataset metadatadataset id/version; supplier/technology; geography; year; boundary; allocation; data quality; component/material matchMatch each material input to a reviewed upstream dataset and document proxy hierarchy where primary supplier data are unavailabledataset referenceAt dataset build and every source updatePrefer data representative of the foreground reporting periodAll purchased inputs across included sitesCoverage table must reconcile every non-zero purchased input to one upstream dataset without double countingSupplier verification, dataset metadata, representativeness assessment and reviewer approval

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
calc_net_finished_massReference normalizationnet finished mass = sum(released unit count by qualified product family × verified net unit mass); exclude separately reported packagingreleased units; qualified product family; sampled unit mass; packaging statekg net finished producteu-pef-method-2021; snia-sss-pts-2-0-2
calc_inventory_normalizationEvery foreground flownormalized amount = reporting-period flow amount / reporting-period net finished product masscollected flow amount; calc_net_finished_mass outputrow unit per 1 kg reference producteu-pef-method-2021
calc_material_reconciliationComponents and materialsopening inventory + receipts - closing inventory - documented returns = incorporated material + recorded scrap/loss + justified inventory varianceinventory, receipt, return, BOM incorporation and waste recordsreconciled input and variance by material/componenteu-pef-method-2021
calc_yield_rework_reconciliationAssembly and testinput units/mass + opening WIP = conforming output + external waste + closing WIP + documented transfers; rework loops remain internal and are reported separatelyinput, output, WIP, rework, reject and waste recordsgross yield, final yield, rework rate and unexplained balanceeu-pef-method-2021
calc_shared_burden_allocationSite supportallocated burden = residual shared total × documented causal-driver share; residual shared total = site total - all direct assignmentssite total; direct assignments; selected physical driver by product family/processallocated shared utility, waste or emission amounteu-pef-method-2021
calc_upstream_coveragePurchased inputscoverage = mass or relevant quantity of purchased inputs linked to reviewed upstream datasets / total purchased input quantity; report uncovered rows separately rather than treating them as zeroreconciled purchased-input table; upstream dataset coverage tablecoverage ratio and uncovered-input listeu-pef-method-2021; boyd-horvath-dornfeld-nand-lca-2011

Data Quality Requirements

requirement_idApplies toRequirementEvidence
dq_product_identityReference product and outputsVerify that the output is a finished CPC 47550 solid-state non-volatile storage device/media and not a bare semiconductor, magnetic/optical medium, reader/drive, storage array, host computer or capacity-specific proxy presented as the generic category.Product master, BOM, photographs/specification, CPC scope review and exact Tiangong flow identity
dq_product_qualifiersProduct mixRetain capacity convention, interface/protocol, speed, form factor, media type, firmware/configuration, application class, enclosure, packaging and production-mix weights for every included family.Controlled product master and released-population extract aligned with SNIA device descriptors
dq_temporal_representativenessForeground recordsUse at least 12 consecutive representative months unless a shorter campaign is justified; identify shutdowns, ramp-up, design transitions and abnormal yields.Dated meter, MES, ERP, test, waste and shipment records plus representativeness justification
dq_geographic_and_technology_matchUpstream datasetsPrefer supplier/site and technology-specific datasets. Document geography, node or memory technology, packaging route, electricity mix, year and proxy limitations for semiconductor and electronic components.Supplier dataset metadata and representativeness assessment
dq_completenessAll inventoryReconcile BOM, energy, water, gas, product, reject, waste and emissions. Unavailable important quantities remain explicit gaps and prevent publication-ready completeness.Signed reconciliation tables, uncovered-input list and gap register
dq_measurement_qualityForeground measurementsRetain meter/scale identification, calibration, sampling, conversion factors, uncertainty and responsible record owner.Calibration certificates, raw exports, sampling plan and calculation workbook
dq_no_double_countingDirect and shared burdensDirect process records plus residual shared allocation must reconcile to site totals; no flow may appear in both direct and shared records.Site reconciliation and allocation worksheet
dq_source_limitationsExternal evidenceDo not transfer numerical values from old semiconductor technology generations, a single SSD model, or another capacity/form factor into the generic PCR. Use such evidence only for boundary, process and qualifier design unless current representative quantitative evidence is provided.Source-use review for every external citation

9. Validation Rules

rule_idApplies toRulesource_ids
validate_reference_identityReference flowThe reference product UUID must equal 4c208ec5-5d80-4547-ab8e-347ef5fb1caf, resolve to state-code 100 Product flow, and retain CPC 47550 identity, Mass property 93a60a56-a3c8-11da-a746-0800200b9a66, Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66, and kg.unsd-cpc-3-0-2025
validate_finished_product_scopeProduct identityReject a package whose reference product is a bare NAND/controller die, wafer, chip, semiconductor intermediate, magnetic/optical medium, removable-media reader/drive, smart card, complete storage system, host computer, software/content, or a single capacity/model flow substituted for the generic category.unsd-cpc-3-0-2025
validate_required_qualifiersProduct metadataFail completeness when any required capacity, interface, form factor, media, firmware/configuration, application class, enclosure/connector, initialization, geography/period, mass, packaging or mix qualifier is missing.snia-sss-pts-2-0-2
validate_reference_massQuantitative referenceNet conforming device output must equal 1 kg after normalization; included packaging mass must be separately visible and must not silently change the device reference mass.eu-pef-method-2021
validate_mass_yield_reconciliationAssembly and testFlag unexplained differences among component/material inputs, work-in-progress changes, conforming output, rework and external waste. The dataset must state and justify its reconciliation tolerance.eu-pef-method-2021
validate_energy_and_utility_reconciliationDirect and shared utilitiesDirectly metered amounts plus residual shared allocation must equal the site total for each utility and period within the declared tolerance, with no double counting.eu-pef-method-2021
validate_upstream_coveragePurchased inputsEvery non-zero purchased component/material/utility/packaging input must link to a reviewed upstream dataset or be reported as an unresolved gap; missing low-mass semiconductor coverage is not accepted as zero.eu-pef-method-2021; boyd-horvath-dornfeld-nand-lca-2011
validate_allocation_disclosureShared and multi-product processesRequire the selected causal driver, numerator, denominator, direct-assignment subtraction, product-mix weighting and justification; flag revenue-only allocation unless physical causality is demonstrably unavailable and review accepts it.eu-pef-method-2021
validate_no_capacity_scalingCross-product useReject conversion between capacities, form factors, technologies or application classes based only on a GB/TB ratio. Require product-specific BOM, yield, test and energy evidence.snia-sss-pts-2-0-2; boyd-horvath-dornfeld-nand-lca-2011
validate_downstream_claimsComparative useA mass-based manufacturing-gate dataset alone is incomplete for comparisons of storage service. Require a separate functional-equivalence model covering capacity convention, workload, performance, endurance/service life, use electricity and end-of-life.eu-pef-method-2021; snia-sss-pts-2-0-2

10. Published Dataset Profile

FieldValue
dataset_roleForeground manufacturing data package for finished solid-state non-volatile storage devices, publishable as a disaggregated or aggregated secondary_dataset or background_dataset after review
downstream_useSupply-chain modelling of finished SSD, flash-card and equivalent CPC 47550 device production; component contribution analysis; downstream device, computer, embedded-equipment or storage-service models that add their own use and end-of-life assumptions
allowed_useUse for the declared capacity/form-factor/technology/application mix and manufacturing geography/period; aggregation across products only with disclosed weights and qualifier preservation
excluded_useBare NAND/chip production; magnetic/optical media or readers; storage arrays/host computers; capacity-only scaling; service-level or comparative environmental claims without functional equivalence, workload, endurance/life, use electricity and end-of-life modules
required_metadataPCR id/version; reference UUID/property/unit group/unit; CPC scope; product qualifiers; product and packaging mass; production sites and period; technology and capacity mix; foreground ownership boundary; upstream dataset table; yield/rework; direct/shared utility split; allocation drivers; source versions; unresolved gaps
required_quality_disclosureTemporal, geographic and technological representativeness; meter/scale calibration; BOM and mass-balance reconciliation; test-recipe coverage; upstream semiconductor dataset quality; allocation sensitivity; proxy limitations; excluded stages; data completeness and uncertainty
update_triggerMaterial product architecture, memory technology, capacity/form-factor mix, test recipe, firmware/configuration, manufacturing site, electricity supply, BOM, yield, packaging, supplier dataset, allocation method, CPC scope, Tiangong UUID identity, or external method source change

11. Data Sources

Source idTypeReferenceUsed for
unsd-cpc-3-0-2025standardUnited Nations Statistics Division. Central Product Classification Version 3.0: Explanatory Notes, 30 June 2025. https://unstats.un.org/unsd/classifications/Econ/Download/In%20Text/CPC_Ver_3.0_Exp_Notes_30Jun2025.pdf (accessed 2026-08-09).CPC 47550 identity; included solid-state non-volatile recording devices/cards; separation from magnetic/optical media, fixed/removable-media storage units, readers and other categories
eu-pef-method-2021official_guidanceEuropean Commission. Commission Recommendation (EU) 2021/2279, Annex I: Product Environmental Footprint Method, 16 December 2021. https://environment.ec.europa.eu/document/download/680503dc-5a19-4f6a-bb92-84d9bfc8f312_en?filename=Annexes+1+to+2.pdf (accessed 2026-08-09).Functional unit, reference flow, life-cycle boundary, foreground/background distinction, data collection and quality, cut-off/completeness, multi-functionality, allocation and reporting rules
snia-sss-pts-2-0-2standardStorage Networking Industry Association. Solid State Storage Performance Test Specification, Version 2.0.2, 1 October 2020. https://www.snia.org/sites/default/files/2025-02/SNIA-SSS-PTS-2.0.2.pdf (accessed 2026-08-09).Device-level scope and required capacity, interface/speed, form-factor, media, firmware and client/enterprise descriptors; test-state and workload disclosure
boyd-horvath-dornfeld-nand-lca-2011literatureBoyd, S. B.; Horvath, A.; Dornfeld, D. Life-Cycle Assessment of NAND Flash Memory. IEEE Transactions on Semiconductor Manufacturing 24(1), 117-124 (2011). DOI: 10.1109/TSM.2010.2087395. Open accepted manuscript: https://escholarship.org/uc/item/2wr9b3t1 (accessed 2026-08-09).NAND fabrication process and inventory significance; electricity, water, chemicals, process emissions, infrastructure and abatement coverage; warning against unsupported cross-technology or capacity extrapolation
samsung-semiconductor-lca-methodliteratureSamsung Semiconductor. Life Cycle Assessment: From raw materials to disposal, efforts to reduce carbon, including third-party-validated PCF system description. https://semiconductor.samsung.com/sustainability/environment/green-technology/life-cycle-assessment/ (accessed 2026-08-09).Current industry evidence for cradle-to-gate raw-material, manufacturing, packaging and test coverage; activity-data collection; electricity, process-gas, water and process-level reporting

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 5
Rule IDApplies toRuleSource IDs
boundary_finished_device_gateForeground manufacturingInclude component receipt and reconciliation, assembly/interconnection, programming or configuration, functional testing and yield disposition, finished-product packaging, and the allocated share of site utilities, abatement, wastewater and waste management needed to deliver conforming finished product at the manufacturing gate.eu-pef-method-2021, samsung-semiconductor-lca-method
boundary_upstream_component_coveragePurchased components and materialsNAND packages, controller and support ICs, substrates/PCBs, connectors, enclosures, joining materials, consumables, utilities, and packaging must retain upstream production through supplier-specific or representative datasets. Do not cut off semiconductor components because their physical mass is small.eu-pef-method-2021, boyd-horvath-dornfeld-nand-lca-2011
boundary_foreground_controlVertically integrated productionWhen wafer fabrication, IC packaging, PCB/substrate manufacture, connector manufacture, or enclosure manufacture is under the reporting organisation's direct control, collect it as additional foreground processes or attach disaggregated site datasets; otherwise use reviewed upstream datasets and disclose the boundary.eu-pef-method-2021, samsung-semiconductor-lca-method
boundary_use_and_end_of_lifeDownstream stagesDistribution, use-phase electricity, maintenance, service-life extension, data erasure, reuse and end-of-life are outside this manufacturing-gate foreground package unless explicitly added as separate downstream modules. A mass-based dataset alone must not support comparative storage-service claims.eu-pef-method-2021, boyd-horvath-dornfeld-nand-lca-2011
boundary_no_unreported_cutoffCompletenessReport all known material, energy, water, process-gas, waste and direct-emission flows. Any unavailable quantity remains a documented data gap; it is not silently treated as zero.eu-pef-method-2021
Allocation rules · 5
Rule IDApplies toRuleSource IDs
allocation_avoid_by_subdivisionMulti-product lines and shared processesFirst avoid allocation by sub-metering, separate production orders, process subdivision, or a documented physical expansion of the measured system.eu-pef-method-2021
allocation_physical_driverShared site utilities, consumables and wastesWhen subdivision is not feasible, use a causal physical driver such as measured equipment energy, machine-hours, test-hours, occupied area with time, material throughput, or net product mass. Explain why the driver represents resource use; do not default to revenue.eu-pef-method-2021
allocation_product_mixMultiple capacities, form factors or technologiesRetain product-specific BOM, mass, test recipe, yield and energy records where available. A production-mix dataset must be mass-weighted or production-weighted from disclosed product-specific records; do not scale solely by capacity.eu-pef-method-2021, snia-sss-pts-2-0-2
allocation_rework_and_internal_recyclingRework and internally returned materialKeep reworked units and internally returned material inside the foreground boundary. Count only net external inputs, conforming outputs and externally transferred wastes, while retaining gross yield and rework records for audit.eu-pef-method-2021
allocation_recovered_materialScrap sold or sent for recoveryRecord the outgoing waste/material quantity and treatment route without an unreviewed avoided-burden credit in the foreground manufacturing dataset. Apply recycling or end-of-life credits only in a declared downstream method that is consistent across compared systems.eu-pef-method-2021
Validation rules · 10
Rule IDApplies toRuleSource IDs
validate_reference_identityReference flowThe reference product UUID must equal 4c208ec5-5d80-4547-ab8e-347ef5fb1caf, resolve to state-code 100 Product flow, and retain CPC 47550 identity, Mass property 93a60a56-a3c8-11da-a746-0800200b9a66, Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66, and kg.unsd-cpc-3-0-2025
validate_finished_product_scopeProduct identityReject a package whose reference product is a bare NAND/controller die, wafer, chip, semiconductor intermediate, magnetic/optical medium, removable-media reader/drive, smart card, complete storage system, host computer, software/content, or a single capacity/model flow substituted for the generic category.unsd-cpc-3-0-2025
validate_required_qualifiersProduct metadataFail completeness when any required capacity, interface, form factor, media, firmware/configuration, application class, enclosure/connector, initialization, geography/period, mass, packaging or mix qualifier is missing.snia-sss-pts-2-0-2
validate_reference_massQuantitative referenceNet conforming device output must equal 1 kg after normalization; included packaging mass must be separately visible and must not silently change the device reference mass.eu-pef-method-2021
validate_mass_yield_reconciliationAssembly and testFlag unexplained differences among component/material inputs, work-in-progress changes, conforming output, rework and external waste. The dataset must state and justify its reconciliation tolerance.eu-pef-method-2021
validate_energy_and_utility_reconciliationDirect and shared utilitiesDirectly metered amounts plus residual shared allocation must equal the site total for each utility and period within the declared tolerance, with no double counting.eu-pef-method-2021
validate_upstream_coveragePurchased inputsEvery non-zero purchased component/material/utility/packaging input must link to a reviewed upstream dataset or be reported as an unresolved gap; missing low-mass semiconductor coverage is not accepted as zero.eu-pef-method-2021, boyd-horvath-dornfeld-nand-lca-2011
validate_allocation_disclosureShared and multi-product processesRequire the selected causal driver, numerator, denominator, direct-assignment subtraction, product-mix weighting and justification; flag revenue-only allocation unless physical causality is demonstrably unavailable and review accepts it.eu-pef-method-2021
validate_no_capacity_scalingCross-product useReject conversion between capacities, form factors, technologies or application classes based only on a GB/TB ratio. Require product-specific BOM, yield, test and energy evidence.snia-sss-pts-2-0-2, boyd-horvath-dornfeld-nand-lca-2011
validate_downstream_claimsComparative useA mass-based manufacturing-gate dataset alone is incomplete for comparisons of storage service. Require a separate functional-equivalence model covering capacity convention, workload, performance, endurance/service life, use electricity and end-of-life.eu-pef-method-2021, snia-sss-pts-2-0-2
Processes and inputs/outputs · 4
Process IDProcess nameInput flowsOutput flows
device_assembly_and_programmingDevice assembly and programming53
functional_test_and_yield_controlFunctional test and yield control33
finished_product_packagingFinished-product packaging33
site_support_and_waste_managementSite support and waste management22

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page

1. Scope and Applicability2. Product Category Identity3. Reference Flow4. Measurement and Unit Rules5. System BoundaryBoundary Abstraction6. Process Inventory StructureProcess MapProcess: Device assembly and programming (device_assembly_and_programming)InputsProduct flowsPurchased non-volatile memory components (purchased_nvm_components)Controllers and support electronics (controller_and_support_electronics)Interconnect and structural components (interconnect_and_structural_components)Joining and assembly materials (joining_and_assembly_materials)Assembly-line electricity (assembly_line_electricity)Waste flowsOutputsProduct flowsAssembled and programmed device transferred to testing (assembled_programmed_device)Waste flowsAssembly scrap and material losses (assembly_scrap_and_losses)Elementary flowsDirect assembly emissions (assembly_direct_emissions)Process: Functional test and yield control (functional_test_and_yield_control)InputsProduct flowsAssembled devices entering test (assembled_devices_entering_test)Test and conditioning electricity (test_and_conditioning_electricity)Test consumables and replacements (test_consumables_and_replacements)OutputsProduct flowsConforming unpackaged devices (conforming_unpacked_devices)Waste flowsFailed devices and test waste (failed_devices_and_test_waste)Elementary flowsDirect test emissions (test_direct_emissions)Process: Finished-product packaging (finished_product_packaging)InputsProduct flowsConforming devices entering packaging (devices_entering_packaging)Primary, secondary and transport packaging (packaging_material_inputs)Packaging-line electricity (packaging_line_electricity)OutputsProduct flowsPackaged finished reference product (packaged_finished_reference_product)Waste flowsPackaging waste (packaging_waste)Elementary flowsDirect packaging emissions (packaging_direct_emissions)Process: Site support and waste management (site_support_and_waste_management)InputsProduct flowsShared site energy and fuels (shared_site_energy_and_fuels)Shared water and process gases (shared_water_and_process_gases)OutputsProduct flowsWaste flowsShared wastewater and solid waste (shared_wastewater_and_solid_waste)Elementary flowsShared direct site emissions (shared_direct_site_emissions)7. Allocation and Co-product Handling8. Foreground Data Collection, Calculation, and Quality RulesData Collection ProtocolsCalculation RulesData Quality Requirements9. Validation Rules10. Published Dataset Profile11. Data Sources