TianGong PCR产品类别规则

Line telephone sets with cordless handsets

Line telephone sets with cordless handsets: This PCR applies to a complete fixed-line cordless telephone configuration placed on the market as one set: a base station…

Lifecycle status
Candidate
Content maturity
Authored methodology
Current version
No published version
Readiness
Review required
Last updated

Methodology and translation states come from the source record; publishing this website does not change their review status.

Content languages

zh-CN · Aligned
Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:47221 · exact

Source

1. Scope and Applicability

This PCR applies to a complete fixed-line cordless telephone configuration placed on the market as one set: a base station connected to a landline telecommunications network, one or more radio-linked cordless handsets, the rechargeable batteries installed or supplied for those handsets, and all power supplies, charging cradles, cables and accessories supplied as necessary for normal operation. It covers household, office and public-communication applications and analogue, VoIP or hybrid landline network interfaces when the product remains a cordless line telephone set.

The declared configuration shall identify the base-station and handset count, radio standard and actual operating frequency band for the intended market, network interface, power-supply and charging arrangement, battery chemistry, capacity, standardized physical size and end-user replaceability, display, keypad, printed circuit boards, housings, acoustic components, cables, accessories and packaging. Packaging is inside the life-cycle boundary but outside the reference product mass.

This PCR excludes cellular or satellite mobile phones, corded-only telephone sets, Wi-Fi-only handsets without a landline-connected base station, independent base stations, independent charging cradles, separately sold additional handsets, network routers and switching equipment, and component-only products. A product with cellular connectivity is not included merely because it can relay a cellular call through a cordless base.

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.metal-products-machinery-and-equipment.radio-television-and-communication-equipment-and-apparatus.line-telephone-sets-with-cordless-handsets
classification_refsCPC 3.0: 47221, Line telephone sets with cordless handsets, exact semantic reference
covered_productsComplete base-station and cordless-handset sets for fixed landline voice communication, including multi-handset configurations and supplied charging equipment
excluded_productsCellular or satellite phones; corded-only phones; Wi-Fi-only handsets; independent base stations, chargers or handsets; routers, switches and component-only products
representative_productOne market-ready fixed-line cordless telephone set with one declared base station, the declared handset count, replaceable rechargeable batteries, supplied power and charging equipment, and retail packaging
production_routeSupplier production of electronic and mechanical components; PCB assembly; housing, display, keypad and acoustic subassembly production; battery and power-supply production; final assembly, programming, testing and packaging
market_stateFinished, tested and packaged set ready for distribution; configuration, target market and network interface declared

3. Reference Flow

FieldValue
WhatFixed-line voice communication provided by a complete cordless telephone set whose handset communicates by radio with the included landline-connected base station
How muchThe service associated with 1 kg of complete reference product mass for the declared configuration
How wellThe declared base and handset count, radio standard and band, network interface, charging arrangement, battery specification and replaceability, display/keypad functions and supplied accessories are preserved
How long or cycleOne declared reference service life and use profile; manufacturing, distribution, use and end-of-life results are normalized to 1 kg of reference product mass
reference_flow_link1 kg of Line telephone sets with cordless handsets ec74af79-0aac-4d55-bf93-f30369e74bfb
FieldValue
Reference amount1 kg
Reference product flowLine telephone sets with cordless handsets ec74af79-0aac-4d55-bf93-f30369e74bfb
Reference flow propertyMass 93a60a56-a3c8-11da-a746-0800200b9a66
Reference unit groupUnits of mass 93a60a57-a4c8-11da-a746-0800200c9a66
Reference unitkg
Required qualifiersbase-station count; handset count; analogue, VoIP or hybrid landline interface; radio standard and operating frequency band; target market; external power-supply and charging-cradle configuration; rechargeable battery chemistry, capacity, standardized physical size, count and replaceability; display and keypad configuration; PCB count; housing materials; supplied cables and accessories; unpackaged product mass; packaging materials and masses; standby, call and charging power; reference service life and use profile

When constructing a foreground data package, the items listed in Required qualifiers must be declared in dataset metadata, process notes, reference flow comment, product description, or an equivalent data package field. Missing required qualifiers make the reference flow definition incomplete for that data package.

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
reference_massreference productMass 93a60a56-a3c8-11da-a746-0800200b9a66kgNormalize every inventory result to 1 kg of complete unpackaged product. Include the base station, declared handsets, installed or supplied batteries, required power supplies, charging cradles, cables and supplied operating accessories; exclude packaging mass and record it separately.
configuration_mass_reconciliationbill of materials and finished productMasskgMeasure the accepted finished configuration and reconcile component and subassembly masses to the unpackaged set mass. Preserve the native measured masses before normalization and explain all residual mass.
standby_power_measurementbase station and every charging cradlePowerWRecord factory-default average power separately for the base station with the charged handset on and off the base, and for every separate charging cradle with the charged handset on and, where measured, off the cradle. Record voltage, frequency, test method, stabilization and averaging interval.
call_power_measurementbase station, handset charging path and supplied power equipmentPowerWRecord average active call power for the declared connection and radio configuration, separately from standby and charging. Record whether the handset is on or off the cradle, call function, display state, audio mode and battery state.
use_energy_conversionuse-stage electricityEnergykWhCalculate electricity as the sum over declared modes of measured power in W multiplied by mode duration in h and divided by 1,000. Keep base standby, separate-cradle standby, call operation and charging terms identifiable.
packaging_mass_separationprimary, secondary and transport packagingMasskgRecord each packaging material and mass separately; do not add packaging to the 1 kg reference product mass.

5. System Boundary

The required boundary is cradle-to-grave for the declared complete set. It includes raw-material and component production, PCB assembly, housing and keypad manufacture, display and acoustic subassemblies, rechargeable batteries, external power supplies and charging equipment, final assembly and testing, packaging, distribution, electricity during standby, calling and charging over the declared service life, replacement batteries and other declared replacement parts, collection, dismantling, recycling, recovery and final treatment.

Boundary Abstraction

FieldValue
declared_starting_conditionIdentified materials and supplier components at their production origin, with final-manufacturing-site records for assembly, testing and packaging
starting_condition_roleCradle-to-grave electronic product system with primary foreground assembly data and traceable upstream component datasets
product_classification_scopeComplete fixed-line cordless telephone sets semantically equivalent to CPC 3.0 code 47221; classification is context, not canonical PCR identity
recursive_input_ruleIf a complete same-category cordless telephone set crosses the boundary as an input, record it once as a traceable upstream product dataset and do not recursively expand the same PCR inside that dataset
upstream_dataset_requirementSupplier-specific or technologically representative cradle-to-gate datasets are required for PCBs, display, keypad, housings, acoustic parts, batteries, power supplies, chargers, cables and packaging; identity, geography, technology and time shall be disclosed
disclosureDeclare configuration, included and excluded accessories, production sites, supplier-data substitutions, transport, radio and network interface, power modes and durations, service life, repairs and battery replacements, packaging and end-of-life scenario
rule_idapplies_torulesource_ids
boundary_complete_lifecycledeclared_product_systemInclude manufacturing, distribution, installation where material, use and end-of-life stages; report any optional benefits and loads beyond the system boundary separately.pep-pcr-ed4-electrical-electronic; itu-t-l1410-2024
boundary_configuration_integrityreference_configurationModel one internally consistent base-and-handset configuration. Do not combine a cordless set with cellular phones, corded-only phones or an independent base station.eu-2023-1670-cordless-phones; energy-star-telephony-v3
boundary_component_completenessmanufacturingInclude the declared PCB, display, keypad, housing, acoustic, battery, power-supply, charging, cable, accessory and packaging inventories; justify any missing supplier dataset and retain its mass in the completeness check.pep-pcr-ed4-electrical-electronic; eu-2023-1670-cordless-phones; eu-weee-2012-19-annex-vii
boundary_use_modesuse_stageInclude measured base and cradle standby, active call and battery charging electricity for the declared configuration and use profile; do not substitute a certification limit for measured foreground power.eu-2023-1670-cordless-phones; energy-star-telephony-v3; pep-pcr-ed4-electrical-electronic
boundary_end_of_lifeend_of_lifeInclude separate handling of batteries, relevant circuit boards, displays, external cables and other regulated components before downstream recycling, recovery or disposal.eu-weee-2012-19-annex-vii; pep-pcr-ed4-electrical-electronic

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
final_assembly_and_packagingComponent supply, final assembly, testing and packagingrequiredAlwaysForeground manufacturing with traceable upstream component production1 kg accepted unpackaged set
distributionDistribution of the packaged setrequiredAlways; actual route or a disclosed scenarioProduct distributiontonne-km and packaging losses normalized to 1 kg product
use_and_chargingStandby, call operation, charging and replacement partsrequiredAlways over the declared service lifeUse-stage electricity and maintenancekWh and replacement-part mass per 1 kg product
end_of_lifeCollection, dismantling and treatmentrequiredAlways using the declared geographic scenarioEnd-of-life treatment1 kg discarded product plus replacement wastes

Process: Component supply, final assembly, testing and packaging (final_assembly_and_packaging)

Inputs

Product flows
Base-station and handset printed circuit board assemblies (pcb_assemblies)

Record every populated PCB assembly supplied to the base station and handsets, including board identity, count, mass, supplier process and production geography.

  • Selected flow: Supplier-specific populated printed circuit board assemblies for the declared base station and handsets
  • Flow property / unit: Mass / kg
  • Amount rule: measured supplier and incoming-inspection mass by PCB assembly type
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg accepted unpackaged set
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_configuration_bom
  • Sources: pep-pcr-ed4-electrical-electronic; eu-weee-2012-19-annex-vii
Display, keypad and acoustic subassemblies (user_interface_subassemblies)

Record the display, keypad or mechanical buttons, microphones, loudspeakers and associated flex circuits by base and handset location.

  • Selected flow: Supplier-specific display, keypad, microphone and loudspeaker subassemblies
  • Flow property / unit: Mass / kg
  • Amount rule: measured bill-of-material and supplier mass for each included subassembly
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg accepted unpackaged set
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_configuration_bom
  • Sources: eu-2023-1670-cordless-phones; pep-pcr-ed4-electrical-electronic; eu-weee-2012-19-annex-vii
Plastic and other housings (housings)

Record base-station, handset and charging-cradle housings by polymer, filler, flame-retardant declaration, colour and manufacturing route; record metallic housing parts separately.

  • Selected flow: Supplier-specific moulded housing parts and other enclosure materials
  • Flow property / unit: Mass / kg
  • Amount rule: measured incoming mass by material and part family
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg accepted unpackaged set
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_configuration_bom
  • Sources: pep-pcr-ed4-electrical-electronic; eu-weee-2012-19-annex-vii
Rechargeable handset batteries (rechargeable_batteries)

Record battery count, chemistry, nominal voltage, capacity, standardized physical size, mass, supplier and whether the battery is replaceable by the end-user with the stated tools.

  • Selected flow: Supplier-specific rechargeable batteries for the declared cordless handsets
  • Flow property / unit: Mass / kg
  • Amount rule: measured supplied battery mass by chemistry and battery type
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg accepted unpackaged set
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_configuration_bom
  • Sources: eu-2023-1670-cordless-phones; eu-2023-1542-batteries; pep-pcr-ed4-electrical-electronic
Power supplies, charging cradles, cables and supplied accessories (power_and_accessories)

Record each external power supply, integrated or separate charging cradle, line cord, network cable and supplied operating accessory for the declared configuration.

  • Selected flow: Supplier-specific power, charging, cable and accessory components supplied with the set
  • Flow property / unit: Mass / kg
  • Amount rule: measured bill-of-material mass by component and configuration count
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg accepted unpackaged set
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_configuration_bom
  • Sources: eu-2023-1670-cordless-phones; energy-star-telephony-v3; pep-pcr-ed4-electrical-electronic
Assembly and test electricity (assembly_electricity)

Record metered electricity for assembly, programming, functional testing, charging during test and packaging operations at the foreground site.

  • Selected flow: Electricity supplied to the final manufacturing site
  • Flow property / unit: Energy / kWh
  • Amount rule: allocated metered electricity for normal production divided by accepted unpackaged product mass
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg accepted unpackaged set
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_assembly_energy_and_waste
  • Sources: pep-pcr-ed4-electrical-electronic
Product packaging (product_packaging)

Record primary, secondary and transport packaging, inserts, labels and manuals by material and mass without adding them to the reference product mass.

  • Selected flow: Configuration-specific packaging materials
  • Flow property / unit: Mass / kg
  • Amount rule: measured packaging mass by material for the packaged reference configuration
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg accepted unpackaged set
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_configuration_bom
  • Sources: pep-pcr-ed4-electrical-electronic
Waste flows
Elementary flows

Outputs

Product flows
Accepted line telephone set with cordless handsets (reference_product_output)

The accepted unpackaged set is the quantitative reference output. Packaging is reported as a separate input and downstream waste.

  • Selected flow: Line telephone sets with cordless handsets ec74af79-0aac-4d55-bf93-f30369e74bfb
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: exactly 1 kg after normalization
  • Value mode: Fixed value (fixed_value)
  • Specificity: Generic (generic)
  • Normalization basis: 1 kg accepted unpackaged set
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Identity reference (identity_reference)
  • Sources:
Waste flows
Assembly rejects and production waste (assembly_rejects)

Record rejected electronics, housings, batteries, cables and packaging scrap separately by material and treatment destination.

  • Selected flow: Site-specific separated manufacturing waste streams
  • Flow property / unit: Mass / kg
  • Amount rule: measured waste mass by waste stream, net of documented rework returned to production
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg accepted unpackaged set
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_assembly_energy_and_waste
  • Sources: pep-pcr-ed4-electrical-electronic
Elementary flows

Process: Distribution of the packaged set (distribution)

Inputs

Product flows
Distribution transport service (distribution_transport)

Record each actual transport leg for the packaged set from the final logistics platform to the place of use.

  • Selected flow: Mode-specific freight transport service
  • Flow property / unit: Transport service / tonne-km
  • Amount rule: packaged shipment mass in tonnes multiplied by route distance in km for each transport leg
  • Value mode: Calculated value (calculated_value)
  • Specificity: Route-specific (route_specific)
  • Normalization basis: per 1 kg accepted unpackaged set
  • Basis kind: Transport service (transport_service)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_distribution_records
  • Sources: pep-pcr-ed4-electrical-electronic
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Packaging discarded at delivery or installation (distribution_packaging_waste)

Record the destination and treatment of packaging discarded before product use.

  • Selected flow: Separated packaging waste by material
  • Flow property / unit: Mass / kg
  • Amount rule: packaging input mass less documented reusable or returned packaging
  • Value mode: Calculated value (calculated_value)
  • Specificity: Scenario-specific (scenario_specific)
  • Normalization basis: per 1 kg accepted unpackaged set
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_distribution_records
  • Sources: pep-pcr-ed4-electrical-electronic
Elementary flows

Process: Standby, call operation, charging and replacement parts (use_and_charging)

Inputs

Product flows
Base-station networked standby electricity (base_station_standby_electricity)

Calculate electricity from measured base-station standby power and the declared hours in each standby configuration over the reference service life.

  • Selected flow: Market-specific electricity supplied during base-station standby
  • Flow property / unit: Energy / kWh
  • Amount rule: sum of measured base standby power multiplied by hours in each handset-on-base and handset-off-base state, divided by 1,000
  • Value mode: Calculated value (calculated_value)
  • Specificity: Scenario-specific (scenario_specific)
  • Normalization basis: declared reference service life per 1 kg product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_power_mode_records
  • Sources: eu-2023-1670-cordless-phones; energy-star-telephony-v3; pep-pcr-ed4-electrical-electronic
  • Range: EU networked-standby conformity screen for a shipped base station
    • Range role: Allowed range (allowed_range)
    • Lower: 0
    • Upper: 1
    • Unit: W
    • Basis: average base-station networked standby power for an EU-regulated product, with or without a charged handset on the base
    • Basis kind: Reference flow (reference_flow)
    • Evidence kind: External source (external_source)
    • Sources: eu-2023-1670-cordless-phones
Separate charging-cradle standby electricity (charging_cradle_standby_electricity)

For every separate cradle without base-station functionality, calculate electricity from measured standby power and declared occupied and unoccupied hours.

  • Selected flow: Market-specific electricity supplied during separate-cradle standby
  • Flow property / unit: Energy / kWh
  • Amount rule: sum over every cradle of measured standby power multiplied by hours in each charged-handset-on and handset-off state, divided by 1,000
  • Value mode: Calculated value (calculated_value)
  • Specificity: Scenario-specific (scenario_specific)
  • Normalization basis: declared reference service life per 1 kg product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_power_mode_records
  • Sources: eu-2023-1670-cordless-phones; energy-star-telephony-v3; pep-pcr-ed4-electrical-electronic
  • Range: EU standby conformity screen for a separate cradle with a charged handset
    • Range role: Allowed range (allowed_range)
    • Lower: 0
    • Upper: 0.6
    • Unit: W
    • Basis: average standby power per EU-regulated separate charging cradle with the charged handset on the cradle
    • Basis kind: Reference flow (reference_flow)
    • Evidence kind: External source (external_source)
    • Sources: eu-2023-1670-cordless-phones
Active call and battery-charging electricity (call_and_charging_electricity)

Record active call power and charging power separately and calculate their electricity from the declared call and charging durations. Do not infer these values from standby limits.

  • Selected flow: Market-specific electricity supplied during calls and battery charging
  • Flow property / unit: Energy / kWh
  • Amount rule: sum of measured active-call and charging power multiplied by corresponding hours, divided by 1,000
  • Value mode: Calculated value (calculated_value)
  • Specificity: Scenario-specific (scenario_specific)
  • Normalization basis: declared reference service life per 1 kg product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_power_mode_records
  • Sources: energy-star-telephony-v3; pep-pcr-ed4-electrical-electronic
Replacement rechargeable batteries (replacement_batteries)

Include replacement batteries required by the declared service-life scenario and retain chemistry, capacity, standardized size and replacement evidence.

  • Selected flow: Supplier-specific compatible replacement rechargeable battery
  • Flow property / unit: Mass / kg
  • Amount rule: measured battery mass multiplied by the documented number of replacements in the service-life scenario
  • Value mode: Calculated value (calculated_value)
  • Specificity: Scenario-specific (scenario_specific)
  • Normalization basis: declared reference service life per 1 kg product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_repair_and_replacement_records
  • Sources: eu-2023-1670-cordless-phones; eu-2023-1542-batteries; pep-pcr-ed4-electrical-electronic
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Spent rechargeable batteries and replaced parts (use_stage_replaced_waste)

Record spent batteries and other replaced parts by type, mass, collection route and treatment destination.

  • Selected flow: Spent batteries and replaced electronic parts by declared waste type
  • Flow property / unit: Mass / kg
  • Amount rule: measured replacement waste mass corresponding to the declared replacement inventory
  • Value mode: Calculated value (calculated_value)
  • Specificity: Scenario-specific (scenario_specific)
  • Normalization basis: declared reference service life per 1 kg product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_repair_and_replacement_records
  • Sources: eu-2023-1542-batteries; eu-weee-2012-19-annex-vii; pep-pcr-ed4-electrical-electronic
Elementary flows

Process: Collection, dismantling and treatment (end_of_life)

Inputs

Product flows
End-of-life collection transport (eol_collection_transport)

Record transport from the collection point to dismantling and final treatment using the declared geography and routes.

  • Selected flow: Mode-specific waste collection transport service
  • Flow property / unit: Transport service / tonne-km
  • Amount rule: transported waste mass in tonnes multiplied by route distance in km
  • Value mode: Calculated value (calculated_value)
  • Specificity: Route-specific (route_specific)
  • Normalization basis: per 1 kg discarded reference product
  • Basis kind: Transport service (transport_service)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_end_of_life_scenario
  • Sources: pep-pcr-ed4-electrical-electronic
Waste flows
Discarded cordless telephone set (discarded_telephone_set)

Record the complete discarded set entering treatment, net of parts documented as reused before waste treatment.

  • Selected flow: Discarded line telephone set with cordless handsets
  • Flow property / unit: Mass / kg
  • Amount rule: 1 kg reference product less documented reuse, with replacement wastes linked separately
  • Value mode: Calculated value (calculated_value)
  • Specificity: Scenario-specific (scenario_specific)
  • Normalization basis: per 1 kg product placed on the market
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_end_of_life_scenario
  • Sources: eu-weee-2012-19-annex-vii; pep-pcr-ed4-electrical-electronic
Elementary flows

Outputs

Product flows
Recovered material fractions (recovered_material_fractions)

Record recovered metal, plastic, glass and other material outputs after dismantling and treatment; report credits beyond the system boundary separately.

  • Selected flow: Scenario-specific recovered material fractions
  • Flow property / unit: Mass / kg
  • Amount rule: measured or documented treatment yield by material fraction
  • Value mode: Calculated value (calculated_value)
  • Specificity: Scenario-specific (scenario_specific)
  • Normalization basis: per 1 kg discarded reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_end_of_life_scenario
  • Sources: eu-weee-2012-19-annex-vii; pep-pcr-ed4-electrical-electronic
Waste flows
Batteries, circuit boards, displays, cables and regulated residuals (regulated_eol_fractions)

Record separately removed batteries, relevant PCBs, displays, external cables, brominated-flame-retardant plastics and final residues by mass and destination.

  • Selected flow: Separately treated regulated electronic waste fractions
  • Flow property / unit: Mass / kg
  • Amount rule: measured dismantling output mass by regulated fraction and final treatment route
  • Value mode: Foreground record (foreground_record)
  • Specificity: Scenario-specific (scenario_specific)
  • Normalization basis: per 1 kg discarded reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_end_of_life_scenario
  • Sources: eu-weee-2012-19-annex-vii; pep-pcr-ed4-electrical-electronic
Elementary flows

7. Allocation and Co-product Handling

rule_idapplies_torulesource_ids
allocation_avoidforeground_manufacturingAvoid allocation by separately metering assembly, test, packaging and waste processes for the declared product configuration wherever feasible.pep-pcr-ed4-electrical-electronic
allocation_physicalshared_processesWhen allocation cannot be avoided, use a physical relationship that represents the shared process, such as accepted product mass, board area, machine time or units produced, and document the choice.pep-pcr-ed4-electrical-electronic
allocation_economic_fallbackshared_processesUse economic allocation only when no defensible physical relationship exists; disclose the prices, period, currency and sensitivity of the result.pep-pcr-ed4-electrical-electronic
allocation_recyclingend_of_lifeKeep treatment burdens inside the declared end-of-life boundary and report benefits or loads from recovered materials beyond the system boundary separately; do not double count avoided production.pep-pcr-ed4-electrical-electronic

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_configuration_bomfinal_assembly_and_packagingconfiguration, components and packagingcontrolled BOM, supplier declaration and measured mass recordmodel and revision; base count; handset count; component and material identity; part and supplier; PCB count and mass; display/keypad/acoustic parts; housing material; battery chemistry, capacity, size, count and replaceability; power and charging equipment; cable/accessory count; product mass; packaging material and massFreeze one saleable configuration, verify against teardown or incoming inspection, weigh product and packaging separately, and reconcile the BOMkg, count, V, Ah or Wh as applicableeach model revision and representative production batchdeclared representative production periodevery final assembly site and material supplier representednormalize each mass to accepted unpackaged product kg; keep site and supplier strata before aggregationsigned BOM revision, scale calibration, supplier specification, teardown or incoming-inspection record and mass reconciliation
cp_assembly_energy_and_wastefinal_assembly_and_packagingassembly electricity and wastemeter, invoice, production and waste recordsmeter start and end; production quantity and mass; accepted output; rejects; rework; waste stream and destinationSubmeter where feasible; otherwise allocate documented site records using the approved allocation rulekWh, kgeach production reporting perioddeclared period representative of normal productionevery final assembly and test site representedsubtract documented non-product loads where separately metered, allocate shared loads, and divide by accepted product massmeter and scale calibration, invoice reconciliation, production logs and waste transfer records
cp_distribution_recordsdistributionroutes and packaging fateshipment and logistics recordspackaged mass; origin; destination; mode; distance; load factor; returned or reusable packaging; packaging treatmentUse actual shipment records; identify every leg and packaging handoffkg, km, tonne-kmrepresentative shipments and whenever routes changedeclared sales and distribution periodtarget-market routes representedcalculate each leg separately and sum after normalization to unpackaged product kgfreight documents, route source, mass record and packaging return evidence
cp_power_mode_recordsuse_and_chargingstandby, call and charging electricitylaboratory power test and use-profile recordbase and cradle count; firmware and factory settings; landline interface; radio standard and frequency band; supply voltage and frequency; handset position; battery state; display/audio mode; standby, call and charging power; stabilization and averaging interval; hours by mode; service life; electricity geographyMeasure the saleable configuration with calibrated instruments and retain separate results for base standby with handset on and off, each separate cradle, active call and chargingW, h, kWheach hardware, firmware, power-supply or configuration revisiontest date plus declared service-life use scenarioeach target-market electrical and radio configuration representedcalculate mode electricity separately, sum over the service life, and divide by unpackaged product masstest report, instrument calibration, configuration photographs, firmware record and use-scenario source
cp_repair_and_replacement_recordsuse_and_chargingbatteries and replacement partsservice, warranty, supplier and scenario recordspart type; battery chemistry, size, capacity and mass; replacement cause; replacement count; service-life timing; replaced-part destinationUse observed service records when available; otherwise declare the reviewed replacement scenario without presenting it as an observed ratekg, counteach model and service-life scenario updatedeclared service lifetarget market and repair channel representedmultiply part mass by documented replacements and keep batteries separate from other partsservice logs, warranty summary, spare-part specification and scenario approval
cp_end_of_life_scenarioend_of_lifecollection, dismantling and treatmentoperator mass balance and route recordcollection rate; transport; reuse; battery, PCB, display, cable and plastic separation; recovered fractions; residual treatment; geographyPrefer operator-specific data; otherwise use a documented geographically representative treatment scenario and disclose substitutionskg, km, tonne-kmeach treatment scenario or operator updatedeclared scenario reference periodmarket-specific collection and treatment systemreconcile incoming discarded mass with reuse, recovered outputs, regulated fractions, emissions and final residuesoperator report, weighing records, permits, chain-of-custody documents and mass balance

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
calc_component_normalizationcomponent and packaging rowsnormalized amount = measured row amount divided by accepted unpackaged product mass; packaging remains a separate rowcomponent mass, packaging mass, accepted product masskg per kg reference productpep-pcr-ed4-electrical-electronic
calc_assembly_energyassembly electricitynormalized electricity = allocated assembly, test and packaging electricity divided by accepted unpackaged product massmetered kWh, allocation driver, accepted product masskWh per kg reference productpep-pcr-ed4-electrical-electronic
calc_distribution_servicedistribution transporttransport service = sum of packaged shipment mass in tonnes multiplied by route distance in km, divided by unpackaged product mass in kgpackaged mass, route distances and modes, unpackaged product masstonne-km per kg reference productpep-pcr-ed4-electrical-electronic
calc_use_electricitystandby, call and charging electricitylifetime kWh = sum over modes and devices of measured power in W multiplied by mode hours and divided by 1,000; report each term before summingmeasured power by mode, device count, mode hours, service life, unpackaged product masskWh per kg reference product over the declared service lifeeu-2023-1670-cordless-phones; energy-star-telephony-v3; pep-pcr-ed4-electrical-electronic
calc_eol_mass_balanceend-of-life treatmentincoming discarded mass = reuse plus recovered products plus separately treated regulated fractions plus final residues, adjusted only for documented process additions or emissionsoperator or scenario mass recordsreconciled kg per kg discarded producteu-weee-2012-19-annex-vii; pep-pcr-ed4-electrical-electronic

Data Quality Requirements

requirement_idApplies toRequirementEvidence
dq_identityreference productFreeze one model revision and saleable configuration; verify the exact product-flow UUID and all required qualifiers.product label, BOM revision, configuration record and Tiangong identity reference
dq_completenessmanufacturing inventoryAccount for every declared PCB, display, keypad, housing, acoustic part, battery, power supply, charger, cable, accessory and packaging item; identify missing supplier datasets without dropping their mass.BOM-to-scale reconciliation, supplier dataset register and missing-data log
dq_measurementmass, energy and power recordsUse calibrated instruments, preserve native readings and units, and document conversions, sampling and allocation.calibration certificates, raw readings and calculation workbook
dq_temporalall foreground dataState the collection dates and demonstrate that the period represents normal production and operation; identify abnormal periods and substitutions.dated production, test, shipment and treatment records
dq_geography_technologyupstream and scenario dataMatch component technology, production geography, electricity market, radio variant, distribution and end-of-life system to the declared product and market.supplier metadata, test configuration, route records and dataset metadata
dq_use_scenariouse stageKeep measured power separate from assumed mode hours and service life; disclose the source and uncertainty of every use-profile term.power test report, scenario approval and sensitivity record
dq_eolend-of-lifeDemonstrate mass balance and separate handling of batteries, relevant PCBs, displays, cables and regulated materials; avoid unsubstantiated recycling credits.operator mass balance, chain of custody and treatment documentation

9. Validation Rules

rule_idapplies_torulesource_ids
validate_scope_configurationdataset_identityFail if the dataset mixes cellular phones, corded-only phones, independent base stations, independent cradles or separately sold handsets with the complete cordless line telephone set.eu-2023-1670-cordless-phones; energy-star-telephony-v3
validate_reference_flowreference_flowRequire product flow ec74af79-0aac-4d55-bf93-f30369e74bfb, Mass 93a60a56-a3c8-11da-a746-0800200b9a66, Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 and kg, with exactly 1 kg after normalization.
validate_radio_and_networkrequired_qualifiersRequire the base and handset count, landline interface, radio standard, operating frequency band and target market; reject a generic DECT label without the actual market band.etsi-en-300-175-1; eu-2023-1670-cordless-phones
validate_component_and_packaging_inventorymanufacturing_inventoryRequire explicit rows or traceable upstream datasets for PCB assemblies, display, keypad/buttons, housings, acoustic parts, batteries, power supplies, charging equipment, cables and packaging, with packaging mass separate from product mass.pep-pcr-ed4-electrical-electronic; eu-2023-1670-cordless-phones; eu-weee-2012-19-annex-vii
validate_power_modesuse_stageRequire measured base standby, separate-cradle standby where present, active call and charging power, plus mode hours and service life; fail if standby limits or brochure values are substituted for measured lifetime electricity without disclosure.eu-2023-1670-cordless-phones; energy-star-telephony-v3; pep-pcr-ed4-electrical-electronic
validate_eu_standby_limitseu_market_claimFor products declared compliant with Regulation (EU) 2023/1670, require base-station networked standby at or below 1 W and separate-cradle standby with a charged handset at or below 0.6 W; also retain the required test settings.eu-2023-1670-cordless-phones
validate_battery_replaceabilitybattery_inventoryRequire rechargeable battery chemistry, capacity, standardized physical size, count, mass and replacement method. For applicable EU market claims, verify the relevant end-user replacement and spare-part requirements rather than assuming compliance.eu-2023-1670-cordless-phones; eu-2023-1542-batteries
validate_eol_separationend_of_lifeRequire an end-of-life mass balance and separate treatment records for batteries, relevant PCBs, displays, external cables and any brominated-flame-retardant plastics or other regulated fractions present.eu-weee-2012-19-annex-vii; pep-pcr-ed4-electrical-electronic

10. Published Dataset Profile

FieldValue
dataset_roleConfiguration-specific foreground product-system dataset for a complete line telephone set with cordless handset or handsets
downstream_usesecondary_dataset; background_dataset
allowed_useLCA of household, office or public fixed-line cordless telephone configurations whose base, handset count, radio and network interface, power and charging arrangement, battery, components, packaging, service life and geography match the dataset
excluded_useCellular or satellite phones, corded-only phones, Wi-Fi-only handsets, independent base stations or cradles, separately sold additional handsets, routers, switches, component-only products, or configurations with materially different handset count, radio band, charging or battery design without adjustment
required_metadataPCR id and version context; product-flow UUID; model and revision; base and handset count; network interface; radio standard and operating band; target market; power supplies and cradles; battery chemistry, capacity, size and replaceability; display, keypad, PCB and housing configuration; product and packaging mass; production sites; use profile; service life; replacements; transport and end-of-life scenario
required_quality_disclosurePrimary versus secondary data share; supplier dataset gaps; mass reconciliation; meter and scale calibration; allocation; temporal, geographic and technological representativeness; power test method; scenario sources; uncertainty and sensitivity; end-of-life mass balance
update_triggerChange to hardware revision, base or handset count, PCB, display, keypad, housing, battery, power supply, charging arrangement, radio standard or band, firmware affecting power, packaging, production site, supplier dataset, use profile, service life, regulation, or end-of-life route

11. Data Sources

Source idTypeReferenceUsed for
eu-2023-1670-cordless-phonesofficial_guidanceEuropean Commission, consolidated Commission Regulation (EU) 2023/1670, ecodesign requirements for smartphones, other mobile phones, cordless phones and slate tablets, https://eur-lex.europa.eu/legal-content/EN/ALL/?uri=CELEX:02023R1670-20250620, retrieved 2026-08-09Cordless-phone, base-station and charging-cradle scope; exclusions from cellular devices; standby limits and test settings; display, buttons, acoustic parts, batteries, chargers and cradles; standardized replaceable rechargeable batteries
eu-2023-1542-batteriesofficial_guidanceEuropean Parliament and Council, Regulation (EU) 2023/1542 concerning batteries and waste batteries, Article 11, https://eur-lex.europa.eu/eli/reg/2023/1542/oj, retrieved 2026-08-09Portable-battery removability, replaceability, instructions and spare-part disclosure where applicable
energy-star-telephony-v3official_guidanceU.S. EPA ENERGY STAR, Final Version 3.0 Telephony Program Requirements and Final Test Method, December 2013, https://www.energystar.gov/sites/default/files/specs/Telephony%20V3%20ENERGY%20STAR%20Program%20Requirements.pdf, retrieved 2026-08-09Base-and-handset configuration, additional-handset distinction, corded and cellular exclusions, standby and active-call mode definitions, representative configuration and power-test documentation
etsi-en-300-175-1standardETSI EN 300 175-1 V2.5.1, Digital Enhanced Cordless Telecommunications Common Interface, Part 1: Overview, August 2013, https://www.etsi.org/deliver/etsi_en/300100_300199/30017501/02.05.01_60/en_30017501v020501p.pdf, retrieved 2026-08-09DECT radio-interface identity and the need to declare the actual regional operating frequency band rather than assume one universal band
pep-pcr-ed4-electrical-electronicstandardPEP Ecopassport Program, PCR edition 4 for Electrical, Electronic and HVAC-R Products, 6 September 2021, https://pep-ecopassport.org/site/wp-content/uploads/2026/06/PCR-4-ed4-EN-2021-09-06-PCR-edition-4.pdf, retrieved 2026-08-09Cradle-to-grave stages, component and packaging coverage, use electricity, distribution, end-of-life, primary data, cut-off control, allocation, normalization and reporting
eu-weee-2012-19-annex-viiofficial_guidanceEuropean Parliament and Council, consolidated Directive 2012/19/EU on waste electrical and electronic equipment, Annex VII, https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=celex:02012L0019-20240408, retrieved 2026-08-09Separate end-of-life handling of batteries, relevant printed circuit boards, displays, external cables, brominated-flame-retardant plastics and other regulated fractions
itu-t-l1410-2024standardITU-T Recommendation L.1410, Methodology for environmental life cycle assessments of information and communication technology goods, networks and services, November 2024, https://www.itu.int/rec/T-REC-L.1410-202411-I, retrieved 2026-08-09ICT-specific LCA framing, life-cycle inventory, data quality, uncertainty and reporting

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 6
Rule IDApplies toRuleSource IDs
system_boundary_rule_1foreground_system_boundaryThe required boundary is cradle-to-grave for the declared complete set. It includes raw-material and component production, PCB assembly, housing and keypad manufacture, display and acoustic subassemblies, rechargeable batteries, external power supplies and charging equipment, final assembly and testing, packaging, distribution, electricity during standby, calling and charging over the declared service life, replacement batteries and other declared replacement parts, collection, dismantling, recycling, recovery and final treatment.
boundary_complete_lifecycledeclared_product_systemInclude manufacturing, distribution, installation where material, use and end-of-life stages; report any optional benefits and loads beyond the system boundary separately.pep-pcr-ed4-electrical-electronic, itu-t-l1410-2024
boundary_configuration_integrityreference_configurationModel one internally consistent base-and-handset configuration. Do not combine a cordless set with cellular phones, corded-only phones or an independent base station.eu-2023-1670-cordless-phones, energy-star-telephony-v3
boundary_component_completenessmanufacturingInclude the declared PCB, display, keypad, housing, acoustic, battery, power-supply, charging, cable, accessory and packaging inventories; justify any missing supplier dataset and retain its mass in the completeness check.pep-pcr-ed4-electrical-electronic, eu-2023-1670-cordless-phones, eu-weee-2012-19-annex-vii
boundary_use_modesuse_stageInclude measured base and cradle standby, active call and battery charging electricity for the declared configuration and use profile; do not substitute a certification limit for measured foreground power.eu-2023-1670-cordless-phones, energy-star-telephony-v3, pep-pcr-ed4-electrical-electronic
boundary_end_of_lifeend_of_lifeInclude separate handling of batteries, relevant circuit boards, displays, external cables and other regulated components before downstream recycling, recovery or disposal.eu-weee-2012-19-annex-vii, pep-pcr-ed4-electrical-electronic
Allocation rules · 4
Rule IDApplies toRuleSource IDs
allocation_avoidforeground_manufacturingAvoid allocation by separately metering assembly, test, packaging and waste processes for the declared product configuration wherever feasible.pep-pcr-ed4-electrical-electronic
allocation_physicalshared_processesWhen allocation cannot be avoided, use a physical relationship that represents the shared process, such as accepted product mass, board area, machine time or units produced, and document the choice.pep-pcr-ed4-electrical-electronic
allocation_economic_fallbackshared_processesUse economic allocation only when no defensible physical relationship exists; disclose the prices, period, currency and sensitivity of the result.pep-pcr-ed4-electrical-electronic
allocation_recyclingend_of_lifeKeep treatment burdens inside the declared end-of-life boundary and report benefits or loads from recovered materials beyond the system boundary separately; do not double count avoided production.pep-pcr-ed4-electrical-electronic
Validation rules · 8
Rule IDApplies toRuleSource IDs
validate_scope_configurationdataset_identityFail if the dataset mixes cellular phones, corded-only phones, independent base stations, independent cradles or separately sold handsets with the complete cordless line telephone set.eu-2023-1670-cordless-phones, energy-star-telephony-v3
validate_reference_flowreference_flowRequire product flow ec74af79-0aac-4d55-bf93-f30369e74bfb, Mass 93a60a56-a3c8-11da-a746-0800200b9a66, Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 and kg, with exactly 1 kg after normalization.
validate_radio_and_networkrequired_qualifiersRequire the base and handset count, landline interface, radio standard, operating frequency band and target market; reject a generic DECT label without the actual market band.etsi-en-300-175-1, eu-2023-1670-cordless-phones
validate_component_and_packaging_inventorymanufacturing_inventoryRequire explicit rows or traceable upstream datasets for PCB assemblies, display, keypad/buttons, housings, acoustic parts, batteries, power supplies, charging equipment, cables and packaging, with packaging mass separate from product mass.pep-pcr-ed4-electrical-electronic, eu-2023-1670-cordless-phones, eu-weee-2012-19-annex-vii
validate_power_modesuse_stageRequire measured base standby, separate-cradle standby where present, active call and charging power, plus mode hours and service life; fail if standby limits or brochure values are substituted for measured lifetime electricity without disclosure.eu-2023-1670-cordless-phones, energy-star-telephony-v3, pep-pcr-ed4-electrical-electronic
validate_eu_standby_limitseu_market_claimFor products declared compliant with Regulation (EU) 2023/1670, require base-station networked standby at or below 1 W and separate-cradle standby with a charged handset at or below 0.6 W; also retain the required test settings.eu-2023-1670-cordless-phones
validate_battery_replaceabilitybattery_inventoryRequire rechargeable battery chemistry, capacity, standardized physical size, count, mass and replacement method. For applicable EU market claims, verify the relevant end-user replacement and spare-part requirements rather than assuming compliance.eu-2023-1670-cordless-phones, eu-2023-1542-batteries
validate_eol_separationend_of_lifeRequire an end-of-life mass balance and separate treatment records for batteries, relevant PCBs, displays, external cables and any brominated-flame-retardant plastics or other regulated fractions present.eu-weee-2012-19-annex-vii, pep-pcr-ed4-electrical-electronic
Processes and inputs/outputs · 4
Process IDProcess nameInput flowsOutput flows
final_assembly_and_packagingComponent supply, final assembly, testing and packaging72
distributionDistribution of the packaged set11
use_and_chargingStandby, call operation, charging and replacement parts41
end_of_lifeCollection, dismantling and treatment22

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page

1. Scope and Applicability2. Product Category Identity3. Reference Flow4. Measurement and Unit Rules5. System BoundaryBoundary Abstraction6. Process Inventory StructureProcess MapProcess: Component supply, final assembly, testing and packaging (final_assembly_and_packaging)InputsProduct flowsBase-station and handset printed circuit board assemblies (pcb_assemblies)Display, keypad and acoustic subassemblies (user_interface_subassemblies)Plastic and other housings (housings)Rechargeable handset batteries (rechargeable_batteries)Power supplies, charging cradles, cables and supplied accessories (power_and_accessories)Assembly and test electricity (assembly_electricity)Product packaging (product_packaging)Waste flowsElementary flowsOutputsProduct flowsAccepted line telephone set with cordless handsets (reference_product_output)Waste flowsAssembly rejects and production waste (assembly_rejects)Elementary flowsProcess: Distribution of the packaged set (distribution)InputsProduct flowsDistribution transport service (distribution_transport)Waste flowsElementary flowsOutputsProduct flowsWaste flowsPackaging discarded at delivery or installation (distribution_packaging_waste)Elementary flowsProcess: Standby, call operation, charging and replacement parts (use_and_charging)InputsProduct flowsBase-station networked standby electricity (base_station_standby_electricity)Separate charging-cradle standby electricity (charging_cradle_standby_electricity)Active call and battery-charging electricity (call_and_charging_electricity)Replacement rechargeable batteries (replacement_batteries)Waste flowsElementary flowsOutputsProduct flowsWaste flowsSpent rechargeable batteries and replaced parts (use_stage_replaced_waste)Elementary flowsProcess: Collection, dismantling and treatment (end_of_life)InputsProduct flowsEnd-of-life collection transport (eol_collection_transport)Waste flowsDiscarded cordless telephone set (discarded_telephone_set)Elementary flowsOutputsProduct flowsRecovered material fractions (recovered_material_fractions)Waste flowsBatteries, circuit boards, displays, cables and regulated residuals (regulated_eol_fractions)Elementary flows7. Allocation and Co-product Handling8. Foreground Data Collection, Calculation, and Quality RulesData Collection ProtocolsCalculation RulesData Quality Requirements9. Validation Rules10. Published Dataset Profile11. Data Sources