TianGong PCR产品类别规则

Luminaires and lighting fittings, designed for use solely with light-emitting diode (LED) light sources

Luminaires and lighting fittings, designed for use solely with light-emitting diode (LED) light sources: This PCR applies to complete luminaires and lighting fittings…

Lifecycle status
Candidate
Content maturity
Authored methodology
Current version
No published version
Readiness
Review required
Last updated

Methodology and translation states come from the source record; publishing this website does not change their review status.

Content languages

zh-CN · Aligned
Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:46533 · exact

Source

1. Scope and Applicability

This PCR applies to complete luminaires and lighting fittings that are designed to operate solely with LED light sources. A covered product distributes, filters, or transforms light and includes the structure and the parts needed to support, fix, protect, connect, thermally manage, and operate the LED light source. Integrated or manufacturer-specified control gear, LED modules, optical parts, wiring, seals, mounting parts, and supplied lighting-control accessories are included when required for the declared configuration.

The PCR covers indoor, outdoor, building, public-space, and road-lighting luminaires when the declared product is a complete marketable fitting. It excludes individual LED dies, packages, modules, lamps, drivers, power supplies, optics, housings, lamp parts, replacement components, non-LED or multi-technology luminaires, illuminated signs, portable self-powered lamps, vehicle lamps, and model-specific accessories sold independently. Emergency-lighting functions require additional applicable rules and must not be represented as ordinary lighting without disclosure.

The primary foreground result is a manufacturer-gate production dataset normalized to 1 kg of complete, tested, packaged-excluded luminaire product. Product count, outgoing luminous flux, on-mode power, assigned lifetime, replaceability, control configuration, and intended application are required qualifiers so that the production dataset can be converted into the lighting-service functional unit and combined with distribution, installation, use, maintenance, and end-of-life scenarios.

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.metal-products-machinery-and-equipment.electrical-machinery-and-apparatus.luminaires-and-lighting-fittings-designed-for-use-solely-with-light-emitting-diode-led-a0afd2c0
classification_refsCPC 3.0 46533, exact
covered_productsComplete luminaires and lighting fittings designed solely for LED light sources, including fixed indoor luminaires, outdoor luminaires, building luminaires, street and road luminaires, and complete fittings with replaceable or non-replaceable LED light sources
excluded_productsLED dies, packages, modules, lamps, drivers or control gear sold alone; lamp parts; incomplete housings or optics; non-LED or mixed-light-source fittings; illuminated signs; portable self-powered lamps; vehicle lamps; specific commercial models represented as the whole category
representative_productA complete grid-connected LED luminaire comprising structure or housing, thermal management, optical system, LED light source or module, driver or control gear, wiring and connectors, seals and fasteners, and any supplied control or mounting accessories
production_routeComponent and subassembly supply or fabrication; luminaire assembly and wiring; functional, safety, electrical and photometric testing; final inspection and packaging at the manufacturer gate
market_stateComplete, functional, tested luminaire at the manufacturer gate; packaging is inventoried separately and is not part of the 1 kg reference product mass

3. Reference Flow

FieldValue
WhatProduce a complete and functional luminaire or lighting fitting designed solely for LED light sources at the manufacturer gate
How much1 kg of complete finished luminaire product, excluding packaging
How wellThe declared configuration passes applicable luminaire safety and functional checks and has documented outgoing luminous flux, total on-mode power, assigned lifetime, LED replaceability, driver or control-gear configuration, and reference control settings
How long or cycleOne representative production period; retain the product data needed to convert the result to 1,000 lm of outgoing artificial luminous flux for 35,000 operating hours
reference_flow_linkled_luminaire_finished_mass
FieldValue
Reference amount1 kg
Reference product flowLuminaires and lighting fittings, designed for use solely with light-emitting diode (LED) light sources 3253c9d6-cf81-41e6-8997-f59f437c3f2d
Reference flow propertyMass 93a60a56-a3c8-11da-a746-0800200b9a66
Reference unit groupUnits of mass 93a60a57-a4c8-11da-a746-0800200c9a66
Reference unitkg
Required qualifierscomplete luminaire configuration; product count per reference kg; net product mass excluding packaging; indoor, outdoor, building or road application; integrated or replaceable LED light source status; LED module identity; driver or control-gear identity and integration status; outgoing luminous flux in lm; total on-mode power in W at reference control settings; assigned lifetime in h and supporting method; correlated colour temperature; control and dimming functions; supply voltage; IP and IK ratings where applicable; manufacturing geography; manufacturer gate; production period

When constructing a foreground data package, every required qualifier must be declared in dataset metadata, process notes, the reference-flow comment, product description, or an equivalent data-package field. A bare LED, LED module, driver, housing, optical part, or unspecified lighting product is not an acceptable reference product for this PCR.

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
reference_product_masscomplete finished luminaire reference productMass 93a60a56-a3c8-11da-a746-0800200b9a66kgReport net mass of the complete functional luminaire excluding packaging. Calibrated weighing or reconciled component masses must support the value, and the product count represented by 1 kg must be retained.
component_and_waste_massmaterial, component, packaging and waste recordsMass 93a60a56-a3c8-11da-a746-0800200b9a66kgRecord mass by material or component family and convert all production-period totals to kg per 1 kg finished luminaire. Do not merge packaging mass into product mass.
outgoing_luminous_fluxdeclared photometric performanceoutgoing luminous fluxlmUse luminaire output, not LED-package or LED-module flux. Record the test method, tested configuration, ambient and control settings, and test report identifier.
luminaire_powercomplete luminaire in on modeelectrical powerWRecord total power of the complete declared lighting circuit, including integrated or required LED sources, driver or control gear, and operating control components, at declared reference control settings.
assigned_lifetimedeclared complete luminaire configurationoperating timehRecord assigned lifetime and its supporting test, projection, warranty, or technical declaration. Distinguish complete-luminaire lifetime from LED-module and driver lifetime and state replaceability.
energy_recordsmanufacturing and test electricity or fuel inputsenergykWh; MJUse metered energy or reconciled invoices and conversion factors. Keep electricity, thermal energy, and fuels separate before normalization.

5. System Boundary

Boundary Abstraction

FieldValue
declared_starting_conditionaccepted_material_component_and_subassembly_lots
starting_condition_rolesupplier-traceable inputs to complete LED-luminaire production
product_classification_scopecomplete LED-only luminaires and lighting fittings; CPC 3.0 46533 is classification context and does not include LED modules, drivers, lamp parts, or non-LED fittings
recursive_input_ruleA purchased input that is itself a complete CPC 46533 luminaire must be recorded as an upstream complete-luminaire dataset and disclosed; it must not be relabelled as an ordinary component or counted again as newly manufactured product
upstream_dataset_requirementSupplier-specific or representative datasets are required for material and component production, inbound transport, and purchased subassemblies; dataset identity, geography, technology, recycled content claims, and data period must be retained
disclosureDeclare which parts are manufactured on site or purchased, the complete bill of materials, supplied accessories, integrated and replaceable elements, production sites, cut-offs, allocation, packaging, test rejects, and the downstream scenarios included or excluded
rule_idApplies toRulesource_ids
sb_complete_productreference product and manufacturing boundaryInclude the structure or housing, thermal and optical parts, LED light source or module, driver or control gear, wiring, connectors, seals, fasteners, and all accessories supplied or required for the declared complete configuration. A component-only system cannot conform.pep-ecopassport-psr-0014-2023; iec-60598-1-2024
sb_cradle_to_gatemanufacturer-gate foreground datasetInclude upstream production and inbound transport of materials, components and subassemblies; on-site part preparation; assembly; wiring; finishing; testing; rework; production waste treatment; and primary and secondary packaging production.pep-ecopassport-pcr-ed4-2021; pep-ecopassport-psr-0014-2023
sb_supplier_componentspurchased LED module, driver, control gear, PCB, optic, housing or other subassemblyUse upstream datasets for purchased components and do not replace a component inventory with only its delivered mass. Record supplier, technology, geography and recycled-content evidence when available.pep-ecopassport-pcr-ed4-2021; pep-ecopassport-psr-0014-2023
sb_downstream_projectionlifecyclemodel or cradle-to-grave resultWhen downstream stages are claimed, include distribution, installation items, electricity at declared power and control settings, maintenance and replacement of light sources and control gear, and end-of-life collection and treatment. Report manufacturing separately from use and end-of-life.pep-ecopassport-psr-0014-2023; eu-2019-2020-light-sources; eu-2012-19-weee
sb_cutoff_disclosureall foreground and upstream inventoryDo not omit a material, component, hazardous substance, energy input, direct release or waste stream merely because its mass is small when it may materially affect results, safety, toxicity, scarcity or end-of-life treatment. Every applied cut-off and its effect must be disclosed.pep-ecopassport-pcr-ed4-2021

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
component_and_subassembly_supplyComponent and Subassembly Supply or FabricationrequiredPurchased items use supplier datasets; on-site fabrication uses site recordsupstream and foreground component productionaccepted component and subassembly output
luminaire_assemblyLuminaire Assembly, Wiring and FinishingrequiredAlways required for a complete luminaireforeground manufacturingassembled luminaire output
functional_safety_photometric_testingFunctional, Safety, Electrical and Photometric TestingrequiredAlways required; applicable tests depend on product and marketforeground quality assuranceconforming tested luminaire output
final_packagingFinal Inspection and PackagingrequiredAlways required for the manufacturer-gate datasetforeground packagingcomplete luminaire shipped from manufacturer gate
distribution_installation_use_maintenanceDistribution, Installation, Use and Maintenance ScenarioconditionalRequired when a lifecyclemodel, lighting-service result, or downstream claim is produceddownstream scenariodeclared complete-luminaire configuration over the scenario period
end_of_life_treatmentEnd-of-Life Collection and TreatmentconditionalRequired when a cradle-to-grave or end-of-life result is produceddownstream scenarioused complete luminaire and replaced components entering treatment

Process: Component and Subassembly Supply or Fabrication (component_and_subassembly_supply)

Inputs

Product flows
Supplier-traceable bill of materials and component lots (bom_component_inputs)

Record each material and component family separately, including structure and housing materials, heat sinks, optical glass or polymers, reflectors and diffusers, LED modules or light sources, printed circuit assemblies, driver or control gear, wiring, connectors, seals, fasteners, sensors, controls, coatings, labels, and supplied mounting accessories.

  • Selected flow: Supplier-specific material, component or subassembly flow matching the recorded item
  • Flow property / unit: Mass / kg
  • Amount rule: Received mass consumed in accepted production, corrected for returns and inventory change; component count must be converted with measured unit mass where mass invoices are unavailable
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per accepted component and subassembly output and ultimately per 1 kg finished luminaire
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_bom_component_receipts
  • Sources: pep-ecopassport-pcr-ed4-2021; pep-ecopassport-psr-0014-2023
Component fabrication energy (component_fabrication_energy)

Record metered electricity, fuel and purchased thermal energy for casting, forming, machining, moulding, coating, printed-circuit assembly, soldering, curing and other on-site component operations. Supplier operations represented by complete upstream datasets are not counted again.

  • Selected flow: Site- and carrier-specific electricity, fuel or thermal-energy flow
  • Flow property / unit: Energy / kWh or MJ
  • Amount rule: Metered process energy or an engineering allocation of reconciled facility energy to the declared production line
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per accepted component and subassembly output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_process_energy
  • Sources: pep-ecopassport-pcr-ed4-2021

Outputs

Product flows
Accepted component and subassembly set (accepted_component_set)

Record the accepted component and subassembly mass transferred to luminaire assembly, separated by the same families used in the bill of materials.

  • Selected flow: Accepted luminaire component and subassembly set
  • Flow property / unit: Mass / kg
  • Amount rule: Measured or reconciled accepted output mass
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: process output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_component_output
  • Sources: pep-ecopassport-psr-0014-2023
Waste flows
Component fabrication scrap and rejects (component_scrap_rejects)

Record metal, polymer, glass, electronic, coating, solvent, sludge and mixed scrap separately by treatment route, including rejected purchased parts not returned to suppliers.

  • Selected flow: Material- and treatment-specific manufacturing waste flow
  • Flow property / unit: Mass / kg
  • Amount rule: Weighed waste dispatched from the process, reconciled with storage change and supplier returns
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per accepted component and subassembly output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_waste_and_rejects
  • Sources: pep-ecopassport-pcr-ed4-2021; pep-ecopassport-psr-0014-2023
Elementary flows
Direct component-fabrication releases (component_direct_releases)

Record measured or permit-reported direct emissions to air and water from on-site fabrication, finishing, coating, soldering, cleaning or wastewater treatment. Do not duplicate releases already included in purchased energy or supplier datasets.

  • Selected flow: Substance- and compartment-specific elementary flow
  • Flow property / unit: Mass / kg
  • Amount rule: Stack, discharge, solvent-balance or permit record attributable to the declared process
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per accepted component and subassembly output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_direct_releases
  • Sources: pep-ecopassport-pcr-ed4-2021

Process: Luminaire Assembly, Wiring and Finishing (luminaire_assembly)

Inputs

Product flows
Accepted structure, optical, LED and control components (assembly_component_inputs)

Record the accepted component set entering assembly, including every item necessary to make the declared luminaire function as sold or specified.

  • Selected flow: Accepted luminaire component and subassembly set
  • Flow property / unit: Mass / kg
  • Amount rule: Issued-to-production mass and count reconciled to accepted assembly output and returns
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per assembled luminaire output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_assembly_material_issue
  • Sources: pep-ecopassport-psr-0014-2023
Assembly auxiliaries and consumables (assembly_auxiliaries)

Record solder, wire, connectors, thermal-interface materials, adhesives, sealants, lubricants, cleaning agents, coatings, labels and other consumables that cross the assembly boundary.

  • Selected flow: Product-specific auxiliary-material flow
  • Flow property / unit: Mass / kg
  • Amount rule: Purchased or issued amount corrected for stock change, returns and separately recorded waste
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per assembled luminaire output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_auxiliary_materials
  • Sources: pep-ecopassport-pcr-ed4-2021
Assembly and finishing energy (assembly_energy)

Record electricity, fuel and thermal energy for assembly, wiring, fastening, sealing, curing, cleaning and finishing.

  • Selected flow: Site- and carrier-specific electricity, fuel or thermal-energy flow
  • Flow property / unit: Energy / kWh or MJ
  • Amount rule: Metered line energy or documented allocation of reconciled facility energy
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per assembled luminaire output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_process_energy
  • Sources: pep-ecopassport-pcr-ed4-2021

Outputs

Product flows
Assembled complete LED luminaire before final testing (assembled_luminaire)

Record the mass and count of complete assembled luminaires transferred to testing, including integrated or specified LED source and control gear.

  • Selected flow: Luminaires and lighting fittings, designed for use solely with light-emitting diode (LED) light sources 3253c9d6-cf81-41e6-8997-f59f437c3f2d
  • Flow property / unit: Mass / kg
  • Amount rule: Measured or reconciled assembled mass and accepted unit count
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: process output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_assembly_output
  • Sources: pep-ecopassport-psr-0014-2023
Waste flows
Assembly scrap, rejects and cleaning waste (assembly_waste)

Record separated electronic, metal, polymer, glass, cable, solder, adhesive, solvent, wipe and mixed wastes, including rework losses that leave the process.

  • Selected flow: Material- and treatment-specific assembly waste flow
  • Flow property / unit: Mass / kg
  • Amount rule: Weighed waste and rejected-unit mass dispatched from the process
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per assembled luminaire output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_waste_and_rejects
  • Sources: pep-ecopassport-pcr-ed4-2021

Process: Functional, Safety, Electrical and Photometric Testing (functional_safety_photometric_testing)

Inputs

Product flows
Assembled luminaire entering test (luminaire_entering_test)

Record the mass and count of assembled complete luminaires submitted for functional, safety, electrical and photometric acceptance.

  • Selected flow: Luminaires and lighting fittings, designed for use solely with light-emitting diode (LED) light sources 3253c9d6-cf81-41e6-8997-f59f437c3f2d
  • Flow property / unit: Mass / kg
  • Amount rule: Tested mass and unit count from test-lot records
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per conforming tested luminaire output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_test_performance
  • Sources: iec-60598-1-2024; pep-ecopassport-psr-0014-2023
Test electricity (test_electricity)

Record electricity consumed during burn-in, safety, electrical, control-function and photometric tests that is not already included in facility allocation.

  • Selected flow: Site-specific electricity supply flow
  • Flow property / unit: Energy / kWh
  • Amount rule: Metered test-bench electricity or tested power multiplied by recorded test duration
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per conforming tested luminaire output
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_test_performance
  • Sources: iec-60598-1-2024

Outputs

Product flows
Conforming tested complete LED luminaire (conforming_tested_luminaire)

Record the net product mass, accepted count, outgoing luminous flux, total on-mode power, control settings, assigned lifetime evidence and applicable safety or conformity report identifiers for the exact declared configuration.

  • Selected flow: Luminaires and lighting fittings, designed for use solely with light-emitting diode (LED) light sources 3253c9d6-cf81-41e6-8997-f59f437c3f2d
  • Flow property / unit: Mass / kg
  • Amount rule: Accepted tested net mass excluding packaging
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: process output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_test_performance
  • Sources: iec-60598-1-2024; pep-ecopassport-psr-0014-2023; eu-2019-2020-light-sources
Waste flows
Test rejects and failed components (test_rejects)

Record rejected luminaires and failed LED modules, drivers, control gear and other replaced parts by mass and treatment route; units successfully reworked remain in the product balance and their added materials and energy are recorded.

  • Selected flow: Product- and treatment-specific electronic equipment waste flow
  • Flow property / unit: Mass / kg
  • Amount rule: Weighed failed units and parts leaving the test or rework system
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per conforming tested luminaire output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_waste_and_rejects
  • Sources: pep-ecopassport-pcr-ed4-2021

Process: Final Inspection and Packaging (final_packaging)

Inputs

Product flows
Conforming tested luminaire entering packaging (tested_luminaire_for_packaging)

Record the complete conforming luminaire mass and count transferred to final inspection and packaging.

  • Selected flow: Luminaires and lighting fittings, designed for use solely with light-emitting diode (LED) light sources 3253c9d6-cf81-41e6-8997-f59f437c3f2d
  • Flow property / unit: Mass / kg
  • Amount rule: Transferred net product mass and count
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per finished luminaire at manufacturer gate
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_packaging_records
  • Sources: pep-ecopassport-psr-0014-2023
Primary and secondary packaging (packaging_materials)

Record boxes, paper and plastic protection, films, foams, pallets, labels and manuals by material and mass; document reusable packaging cycles separately.

  • Selected flow: Material-specific packaging flow
  • Flow property / unit: Mass / kg
  • Amount rule: Packaging issued per packed product, corrected for reuse and packaging scrap
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per finished luminaire at manufacturer gate
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_packaging_records
  • Sources: pep-ecopassport-pcr-ed4-2021; pep-ecopassport-psr-0014-2023

Outputs

Product flows
Complete finished LED luminaire at manufacturer gate (finished_led_luminaire)

This output is the reference product. Packaging is inventoried with the product system but excluded from the 1 kg product mass.

  • Selected flow: Luminaires and lighting fittings, designed for use solely with light-emitting diode (LED) light sources 3253c9d6-cf81-41e6-8997-f59f437c3f2d
  • Flow property / unit: Mass / kg
  • Amount rule: fixed reference output of 1 kg net complete luminaire, with product count retained
  • Value mode: Fixed value (fixed_value)
  • Specificity: Not applicable (not_applicable)
  • Normalization basis: reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Identity reference (identity_reference)
  • Collection protocol: cp_packaging_records
  • Sources:
Waste flows
Packaging operation waste (packaging_waste)

Record damaged and trimmed cardboard, paper, film, foam, wood and other packaging waste by mass and treatment route.

  • Selected flow: Material- and treatment-specific packaging waste flow
  • Flow property / unit: Mass / kg
  • Amount rule: Weighed packaging waste from the declared packing operation
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per finished luminaire at manufacturer gate
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_waste_and_rejects
  • Sources: pep-ecopassport-pcr-ed4-2021

Process: Distribution, Installation, Use and Maintenance Scenario (distribution_installation_use_maintenance)

Inputs

Product flows
Finished luminaire and installation items (installed_luminaire_inputs)

For a lifecycle projection, record the finished luminaire, actual distribution, remote power supply, fixing elements, connectors, mounting accessories and other manufacturer-required installation items not already delivered with the product.

  • Selected flow: Finished complete LED luminaire and item-specific installation flows
  • Flow property / unit: Mass / kg
  • Amount rule: Scenario quantity derived from product mass, shipment and installation records
  • Value mode: Foreground record (foreground_record)
  • Specificity: Scenario-specific (scenario_specific)
  • Normalization basis: per declared complete-luminaire configuration or service reference
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_distribution_installation
  • Sources: pep-ecopassport-psr-0014-2023
Use electricity and replacement components (use_electricity_replacements)

Record electricity for the complete luminaire at declared reference control settings and actual operating schedule, plus replacement LED light sources, drivers, control gear and other required maintenance items over the declared scenario.

  • Selected flow: Geography- and voltage-specific electricity flow and exact replacement-component flows
  • Flow property / unit: Energy / kWh; Mass / kg
  • Amount rule: Calculate from recorded power, operating and standby hours, control schedule and component replacement records; do not use generic savings assumptions as foreground facts
  • Value mode: Calculated value (calculated_value)
  • Specificity: Scenario-specific (scenario_specific)
  • Normalization basis: per declared complete-luminaire configuration or service reference
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_use_maintenance
  • Sources: pep-ecopassport-psr-0014-2023; eu-2019-2020-light-sources

Outputs

Product flows
Documented lighting service and used luminaire (lighting_service_and_used_luminaire)

Retain the delivered outgoing luminous flux, operating time, power and control scenario together with the used luminaire mass transferred to end-of-life. This is a scenario output and does not replace the complete-luminaire product identity.

  • Selected flow: Documented lighting-service record and complete used luminaire
  • Flow property / unit: luminous flux / lm; operating time / h; Mass / kg
  • Amount rule: Recorded or calculated service performance and used-product mass for the declared scenario
  • Value mode: Calculated value (calculated_value)
  • Specificity: Scenario-specific (scenario_specific)
  • Normalization basis: per declared complete-luminaire configuration or service reference
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_use_maintenance
  • Sources: pep-ecopassport-psr-0014-2023
Waste flows
Installation and maintenance wastes (installation_maintenance_waste)

Record installation packaging, replaced LED sources or modules, drivers, control gear and other maintenance wastes by mass and actual treatment route.

  • Selected flow: Material- and treatment-specific packaging or WEEE flow
  • Flow property / unit: Mass / kg
  • Amount rule: Weighed or component-mass-derived waste from installation and maintenance records
  • Value mode: Foreground record (foreground_record)
  • Specificity: Scenario-specific (scenario_specific)
  • Normalization basis: per declared complete-luminaire configuration or service reference
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_use_maintenance
  • Sources: pep-ecopassport-psr-0014-2023; eu-2012-19-weee

Process: End-of-Life Collection and Treatment (end_of_life_treatment)

Inputs

Waste flows
Used complete luminaire and replaced electrical parts (used_luminaire_weee_input)

Record the complete used luminaire and separately accumulated LED sources or modules, drivers, control gear and other electrical parts entering the actual collection and treatment system.

  • Selected flow: Treatment-specific waste electrical and electronic equipment flow for luminaires and parts
  • Flow property / unit: Mass / kg
  • Amount rule: Scenario mass reconciled to installed product and maintenance replacements
  • Value mode: Foreground record (foreground_record)
  • Specificity: Scenario-specific (scenario_specific)
  • Normalization basis: per declared complete-luminaire configuration or service reference
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_end_of_life
  • Sources: pep-ecopassport-psr-0014-2023; eu-2012-19-weee

Outputs

Product flows
Recovered material outputs (recovered_material_outputs)

Record only material outputs that meet the declared end-of-waste boundary, separated by material and supported by treatment records. Keep optional substitution benefits outside the product-system inventory and report them separately.

  • Selected flow: Material-specific recovered product flow
  • Flow property / unit: Mass / kg
  • Amount rule: Measured or operator-reported recovered mass after treatment
  • Value mode: Foreground record (foreground_record)
  • Specificity: Scenario-specific (scenario_specific)
  • Normalization basis: per treated used-luminaire mass
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_end_of_life
  • Sources: pep-ecopassport-pcr-ed4-2021; eu-2012-19-weee
Waste flows
Final treatment residues (end_of_life_residues)

Record residues to recycling, energy recovery, incineration and landfill without using unverified generic rates in place of actual scenario evidence.

  • Selected flow: Material- and treatment-specific final residue flow
  • Flow property / unit: Mass / kg
  • Amount rule: Treatment-operator mass balance by route
  • Value mode: Foreground record (foreground_record)
  • Specificity: Scenario-specific (scenario_specific)
  • Normalization basis: per treated used-luminaire mass
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_end_of_life
  • Sources: pep-ecopassport-psr-0014-2023; eu-2012-19-weee
Elementary flows
Direct treatment releases (end_of_life_direct_releases)

Record treatment-facility direct emissions to air, water and soil when they are not already represented in the selected treatment datasets.

  • Selected flow: Substance- and compartment-specific elementary flow
  • Flow property / unit: Mass / kg
  • Amount rule: Treatment-operator measurement, permit report or verified facility inventory
  • Value mode: Foreground record (foreground_record)
  • Specificity: Scenario-specific (scenario_specific)
  • Normalization basis: per treated used-luminaire mass
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_end_of_life
  • Sources: eu-2012-19-weee

7. Allocation and Co-product Handling

rule_idApplies toRulesource_ids
alloc_avoid_where_possiblemulti-output foreground operationsSubdivide processes or use direct metering and physical tracking before applying allocation. Document the unallocated inventory and the reason subdivision is not feasible.pep-ecopassport-pcr-ed4-2021
alloc_coproduct_massprocess that produces more than one valuable co-productAllocate residual shared burdens by the mass of output co-products when direct assignment or subdivision is not feasible, and disclose output masses and the calculation.pep-ecopassport-psr-0014-2023
alloc_recycling_boundaryproduction scrap and end-of-life recoveryAssign collection and treatment to the stage that generates the waste through the declared end-of-waste point. Do not subtract avoided virgin-material or energy burdens from the foreground inventory; report optional benefits beyond the boundary separately.pep-ecopassport-pcr-ed4-2021; pep-ecopassport-psr-0014-2023
alloc_rework_and_rejectsreworked and rejected luminaires or componentsAssign added materials, energy and treatment to the production that generated the rework or reject. Returned supplier parts must be reconciled and must not be counted both as consumed input and on-site waste.pep-ecopassport-pcr-ed4-2021

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_bom_component_receiptscomponent_and_subassembly_supplymaterial, component and subassembly inputsERP purchase, goods-receipt, BOM and supplier recorditem id; supplier; site; quantity; unit; unit mass; material family; recycled content; returned quantity; opening and closing stock; upstream dataset refreconcile BOM issues, receipts, returns and stock change; verify representative unit masseskg; itemper lot or receiptrepresentative production period, normally at least 12 consecutive monthsevery production and subcontracting site in scopeaggregate by item and site, then normalize to accepted component output and 1 kg finished productapproved BOM; invoice or receipt; calibrated scale record; supplier declaration; upstream dataset identity
cp_process_energycomponent_and_subassembly_supply; luminaire_assemblyfabrication, assembly and finishing energymeter, fuel delivery and utility invoicemeter id; carrier; start and end reading; fuel amount; conversion factor; line runtime; facility total; allocation driverprefer submetering; otherwise reconcile invoices and allocate using documented causal driverkWh; MJmonthly and per campaign where availablesame period as production outputeach included site and linesum by carrier and site, subtract excluded loads, allocate and normalize to process outputmeter calibration; invoice reconciliation; allocation worksheet
cp_component_outputcomponent_and_subassembly_supplyaccepted components and subassembliesproduction and quality recorditem id; accepted mass; accepted count; reject mass; date; destinationcalibrated weighing or accepted count multiplied by verified unit masskg; itemper lotrepresentative production periodeach included fabrication or supplier sitesum accepted output by family and reconcile to inputs and wastescale calibration; quality-release record; unit-mass study
cp_waste_and_rejectscomponent_and_subassembly_supply; luminaire_assembly; functional_safety_photometric_testing; final_packagingscrap, rejects and process wastewaste ticket, reject log and storage recordwaste type; material; mass; treatment route; haulier; receiver; rejected item count; returned-to-supplier quantity; opening and closing storageweigh dispatched waste and reconcile reject logs, returns and storage changekgper shipment and monthlysame period as production outputall included sitesaggregate by process, material and treatment route; normalize to accepted outputcalibrated weighbridge; waste transfer note; receiver certificate; reject disposition record
cp_direct_releasescomponent_and_subassembly_supplydirect releases to air, water and soilstack, discharge, solvent-balance and permit recordsubstance; compartment; measured concentration; flow; duration; calculated mass; method; detection limituse facility monitoring or documented mass balance and isolate the declared process contributionkgas monitored and at least annuallysame period as production outputevery emitting site in scopecalculate mass by substance and allocate only with documented causal driverlaboratory report; permit report; monitoring calibration; mass-balance worksheet
cp_assembly_material_issueluminaire_assemblycomponents issued and assembled productwork order, material issue and return recordwork order; product configuration; item id; issued quantity; returned quantity; accepted unit count; product massreconcile issued and returned items to accepted assembly outputkg; itemper work orderrepresentative production periodeach assembly siteaggregate by configuration and site, then normalize to assembled outputcontrolled BOM; work-order closeout; scale record
cp_auxiliary_materialsluminaire_assemblysolder, adhesives, sealants, cleaning and other auxiliariespurchase, issue and stock recordmaterial id; amount; unit; stock change; returned amount; waste amountreconcile purchases or issues with stock change and wastekgmonthly or per campaignrepresentative production periodeach assembly siteaggregate by material and normalize to assembled outputinvoice; material issue; inventory reconciliation; safety data sheet
cp_assembly_outputluminaire_assemblyassembled complete luminaireproduction completion recordconfiguration; accepted count; net unit mass; rework count; dateaccepted count multiplied by verified unit mass or total calibrated weighingkg; itemper lotrepresentative production periodeach assembly sitesum accepted mass and count; reconcile to component inputs and wastescale calibration; final assembly record; BOM reconciliation
cp_test_performancefunctional_safety_photometric_testingtested product, test electricity and declared performancetest-lot record and accredited or controlled test reportconfiguration; serial or lot id; tested count; pass/fail; test duration; power; outgoing luminous flux; control setting; supply voltage; CCT; IP/IK where applicable; lifetime evidence; report idapply the relevant luminaire test method to the complete declared configuration; link results to production lotskg; item; h; W; kWh; lm; Kper qualification and routine test plancurrent product design and production periodeach tested configuration and responsible laboratoryaggregate routine test energy and rejects; retain configuration-specific performance without averaging incompatible variantslaboratory accreditation or competence evidence; test method; equipment calibration; signed report; conformity record
cp_packaging_recordsfinal_packagingproduct and packaging at manufacturer gatepackaging BOM, issue, reuse and shipment recordpackaging item; material; mass; units per product; reuse cycles; product count; net product mass; shipment dateweigh representative packaging items and reconcile issues to packed outputkg; item; reuse cycleper packaging design and shipment periodrepresentative production periodeach packing siteaggregate by material, divide reusable packaging by documented uses, and normalize to 1 kg net productpackaging specification; scale record; issue record; reuse log
cp_distribution_installationdistribution_installation_use_maintenancedistribution and installation scenarioshipment and installation recordorigin; destination; mode; distance; load factor; product and packaging mass; remote power supply; fixing and connector items; installation wasteuse actual logistics and installation records or a separately identified justified scenariokg; km; tkmper route or projectdeclared scenario perioddeclared market and installation sitescalculate transport work and installed-item inventory per declared configurationbill of lading; route evidence; installation specification; project record
cp_use_maintenancedistribution_installation_use_maintenanceuse electricity, service and replacementspower test, operating schedule, control log and maintenance recordon-mode power; standby power; control setting; operating hours; outgoing luminous flux; assigned lifetime; component lifetime; replacement date and mass; electricity geographycombine complete-luminaire power at reference settings with recorded or explicitly scenario-defined operating hours; use actual maintenance records where availableW; kWh; h; lm; kgcontinuous or per operating and maintenance eventdeclared service scenariodeclared application and geographycalculate energy and replacements per configuration and service reference; keep measured facts separate from scenario assumptionspower and photometric test report; control-system log; maintenance order; component declaration
cp_end_of_lifeend_of_life_treatmentcollection, sorting, recovery and final residuestake-back, recycler and treatment recordcollected mass; component or material category; transport; treatment route; recovered output; residue; destination; operator and permituse actual scheme or operator mass balance; identify any separately modelled scenariokg; km; tkmper batch or reporting yeardeclared end-of-life scenariodeclared market and treatment systemreconcile input mass to recovered outputs and residues and normalize to treated producttransfer note; treatment certificate; operator mass balance; permit; producer-responsibility evidence

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
normalize_inventory_to_kg_productmanufacturing inventory rowsnormalized amount = attributable production-period amount / net accepted complete-luminaire mass in the same periodprotocol records for input, output, waste or release; cp_assembly_output; cp_packaging_recordsflow amount per 1 kg complete finished luminairepep-ecopassport-pcr-ed4-2021
reconcile_product_masscomplete product and packagingreconcile component and auxiliary inputs to net product, production wastes, direct mass releases, returns and inventory change; packaging is reconciled separately and excluded from product masscp_bom_component_receipts; cp_auxiliary_materials; cp_waste_and_rejects; cp_direct_releases; cp_packaging_recordsdocumented product and packaging mass balancespep-ecopassport-pcr-ed4-2021; pep-ecopassport-psr-0014-2023
calculate_test_electricitytesting processtest electricity (kWh) = complete-luminaire electrical power (kW) x energized test duration (h), plus separately metered test-bench auxiliariescp_test_performancekWh test electricity per conforming outputiec-60598-1-2024
convert_to_lighting_service_referencedownstream comparative service resultservice-equivalent product mass = product mass per declared configuration x (1,000 lm / outgoing luminaire flux in lm) x (35,000 h / assigned luminaire lifetime in h); apply stage-specific inventories without mixing manufacturing, use and end-of-lifecp_test_performance; cp_packaging_records; cp_use_maintenanceproduct quantity and stage inventories per 1,000 lm for 35,000 hpep-ecopassport-psr-0014-2023
calculate_use_electricitydownstream use scenariouse electricity = sum over operating modes of complete-luminaire power (kW) x recorded or declared hours in that mode; include required driver, control gear and control components and state reference control settingscp_test_performance; cp_use_maintenancekWh per declared configuration or service referencepep-ecopassport-psr-0014-2023; eu-2019-2020-light-sources
calculate_replacementsdownstream maintenance scenariocalculate replacement quantities from documented component lifetimes, replaceability and scenario duration; round physical replacement counts to whole events and exclude a replacement where the complete product is retired firstcp_test_performance; cp_use_maintenancereplacement component counts, masses and associated inventoriespep-ecopassport-psr-0014-2023
reconcile_end_of_lifeend-of-life processcollected input mass = recovered product outputs + treatment residues + measured direct mass releases, adjusted only for documented storage changecp_end_of_lifemass-balanced treatment inventorypep-ecopassport-pcr-ed4-2021; eu-2012-19-weee

Data Quality Requirements

requirement_idApplies toRequirementEvidence
dq_product_identityreference productEvidence must show that the dataset represents a complete LED-only luminaire, not a source, module, driver, part, non-LED fitting or individual model standing in for an undeclared family.controlled product specification; configuration BOM; CPC scope check; TianGong reference-flow UUID
dq_bom_completenessbill of materialsThe BOM must cover the complete structure, optical, thermal, LED, electronic, wiring, fastening, sealing, control and supplied-accessory configuration and reconcile with net product mass and waste.approved BOM; component receipts; unit-mass study; mass-balance worksheet
dq_primary_dataforeground manufacturingUse records from the actual sites producing the declared product. Report temporal coverage, production volume coverage, missing records, allocations and subcontracted operations.site list; metering coverage; ERP extracts; production ledger; supplier records
dq_performance_configurationphotometric, power and lifetime dataTest and technical evidence must refer to the complete declared configuration and reference control settings. LED-package values cannot substitute for luminaire output or power.signed test report; test method; calibration; configuration cross-reference; lifetime evidence
dq_upstream_datamaterials and purchased componentsMatch datasets to material or component technology, supplier or region, production route and time period. Disclose proxies and do not present an unverified recycled-content or supplier claim as measured fact.upstream dataset metadata; supplier declaration; data-quality assessment; proxy register
dq_mass_energy_waste_balanceeach foreground processReconcile inputs, accepted outputs, waste, returns, stock change, energy and direct releases for the same period. Investigate and disclose material residuals or inconsistent meters before publication.signed reconciliation; calibration evidence; invoice cross-check; waste transfer records
dq_downstream_scenarioslifecycle projectionsIdentify geography, transport, installation items, operating schedule, grid dataset, controls, maintenance, component replacements and end-of-life system. Keep scenario assumptions distinct from foreground observations.scenario register; shipment and project records; power and control logs; recycler evidence
dq_no_unsupported_estimatesall quantitative inventoryForeground collection is required when no reliable category-generic quantity exists. Any temporary modelled estimate must be explicitly labelled, replaceable, sensitivity-tested and excluded from claims of measured or reviewed performance.estimate register; sensitivity result; replacement plan; reviewer disposition

9. Validation Rules

rule_idApplies toRulesource_ids
val_reference_identityreference flowThe reference product flow UUID must be 3253c9d6-cf81-41e6-8997-f59f437c3f2d, flow type Product flow, CPC 46533, state code 100, with Mass property 93a60a56-a3c8-11da-a746-0800200b9a66, Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66, and kg.
val_complete_luminaireproduct identity and BOMReject datasets for a single LED die, package, module, lamp, driver, power supply, optical part, housing, generic lamp part, non-LED fitting, or an incomplete configuration.pep-ecopassport-psr-0014-2023; eu-2019-2020-light-sources
val_reference_amountreference outputThe normalized output must equal 1 kg net complete luminaire excluding packaging, and the corresponding product count must be declared.pep-ecopassport-pcr-ed4-2021
val_required_qualifiersdataset metadataAll required qualifiers in the reference-flow table must be present and traceable to the declared product configuration and production period.pep-ecopassport-psr-0014-2023
val_process_coveragemanufacturer-gate datasetComponent and subassembly supply or fabrication, assembly and finishing, testing and rework, final packaging, production wastes, direct releases and upstream datasets must be covered or explicitly documented as not applicable without hiding a supplied component.pep-ecopassport-pcr-ed4-2021; pep-ecopassport-psr-0014-2023
val_performance_evidenceoutgoing flux, power and lifetimeOutgoing flux and power must be for the complete luminaire at recorded reference control settings; lifetime and replaceability must be supported and must distinguish luminaire, LED source and control gear.pep-ecopassport-psr-0014-2023; iec-60598-1-2024; eu-2019-2020-light-sources
val_mass_balanceproduct, component, packaging and waste recordsProduct and packaging mass balances must reconcile for aligned periods. Packaging must not be included in the product reference mass, and supplier returns or rework must not be double counted.pep-ecopassport-pcr-ed4-2021
val_allocationshared facilities and co-productsEvery allocated flow must identify the unallocated total, allocation driver and receiving outputs. Residual co-product allocation must use output mass unless a reviewed direct assignment or subdivision is documented.pep-ecopassport-psr-0014-2023
val_lifecycle_claimlifecyclemodel or lighting-service resultA claim covering the lighting service or cradle-to-grave result must include distribution, installation, use electricity, maintenance and replacements, and end-of-life; it must not present the 1 kg manufacturer-gate dataset alone as a full lifecycle result.pep-ecopassport-psr-0014-2023; eu-2012-19-weee
val_evidence_and_estimatesquantitative and source recordsReject unsupported fixed values, unlabelled estimates, missing source references for external rules, or reasoned estimates presented as final evidence.pep-ecopassport-pcr-ed4-2021

10. Published Dataset Profile

FieldValue
dataset_rolemanufacturer-gate foreground unit process for a complete LED-only luminaire; optional input to a declared lifecyclemodel
downstream_usesecondary_dataset; background_dataset; lifecyclemodel component for building, road, public-space and other declared lighting applications
allowed_useProduction datasets and downstream scenarios for complete CPC 46533 LED-only luminaires with matching configuration, geography, technology, performance, control, lifetime and data-quality disclosures
excluded_useIndividual LED sources, modules, drivers, parts or non-LED fittings; automatic substitution across incompatible luminaire configurations or applications; claims about use-phase energy or full life cycle based only on the manufacturer-gate dataset
required_metadatacanonical PCR id; reference-flow UUID and mass property; product count per kg; net product and packaging mass; complete BOM; supplied and integrated components; production sites and period; geography; outgoing luminous flux; total power and reference control settings; lifetime and replaceability; CCT; supply voltage; IP and IK where applicable; process coverage; upstream datasets; allocation and cut-offs
required_quality_disclosurePrimary-data temporal and site coverage; BOM and mass-balance completeness; meter and test calibration; photometric and lifetime evidence; upstream data quality and proxies; allocation; waste routes; excluded processes; modelled estimates; uncertainty and sensitivity; downstream scenario assumptions when applicable
update_triggerChange to product boundary, LED or driver technology, BOM or material share, supplier or manufacturing geography, production route, power or outgoing flux, control setting, lifetime or replaceability, packaging, allocation, upstream dataset, energy mix, waste route, regulation, test method, or material data-quality finding

11. Data Sources

Source idTypeReferenceUsed for
pep-ecopassport-pcr-ed4-2021standardPEP Ecopassport, Product Category Rules for Electrical, Electronic and HVAC-R Products, PCR-ed4-EN-2021 09 06, https://register.pep-ecopassport.org/documents (retrieved 2026-08-09)cradle-to-gate and lifecycle boundary; component, transport, assembly, packaging and waste coverage; functional and declared units; data quality and allocation framework
pep-ecopassport-psr-0014-2023standardPEP Ecopassport, PSR-0014-ed2.0-EN-2023 07 13, Specific Rules for Luminaires, https://register.pep-ecopassport.org/documents/public/PSR-0014-EN (retrieved 2026-08-09)luminaire definition and exclusions; complete-component configuration; 1,000 lm for 35,000 h service reference; system boundary; testing and performance metadata; use, maintenance and end-of-life rules; mass allocation
iec-60598-1-2024standardIEC 60598-1:2024, Luminaires - Part 1: General requirements and tests, https://webstore.iec.ch/en/publication/66620 (retrieved 2026-08-09)complete-luminaire safety, marking, mechanical and electrical construction, and test-evidence boundary
eu-2019-2020-light-sourcesstandardCommission Regulation (EU) 2019/2020 on ecodesign requirements for light sources and separate control gears, consolidated text, https://eur-lex.europa.eu/eli/reg/2019/2020/2021-09-01/eng (retrieved 2026-08-09)distinction among luminaire containing product, LED light source and control gear; complete-product reference control settings, power and replaceability context
eu-2012-19-weeestandardDirective 2012/19/EU on waste electrical and electronic equipment (WEEE), https://eur-lex.europa.eu/eli/dir/2012/19/oj/eng (retrieved 2026-08-09)separate collection, recovery, recycling, treatment and evidence requirements for lighting-equipment end-of-life scenarios

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 5
Rule IDApplies toRuleSource IDs
sb_complete_productreference product and manufacturing boundaryInclude the structure or housing, thermal and optical parts, LED light source or module, driver or control gear, wiring, connectors, seals, fasteners, and all accessories supplied or required for the declared complete configuration. A component-only system cannot conform.pep-ecopassport-psr-0014-2023, iec-60598-1-2024
sb_cradle_to_gatemanufacturer-gate foreground datasetInclude upstream production and inbound transport of materials, components and subassemblies; on-site part preparation; assembly; wiring; finishing; testing; rework; production waste treatment; and primary and secondary packaging production.pep-ecopassport-pcr-ed4-2021, pep-ecopassport-psr-0014-2023
sb_supplier_componentspurchased LED module, driver, control gear, PCB, optic, housing or other subassemblyUse upstream datasets for purchased components and do not replace a component inventory with only its delivered mass. Record supplier, technology, geography and recycled-content evidence when available.pep-ecopassport-pcr-ed4-2021, pep-ecopassport-psr-0014-2023
sb_downstream_projectionlifecyclemodel or cradle-to-grave resultWhen downstream stages are claimed, include distribution, installation items, electricity at declared power and control settings, maintenance and replacement of light sources and control gear, and end-of-life collection and treatment. Report manufacturing separately from use and end-of-life.pep-ecopassport-psr-0014-2023, eu-2019-2020-light-sources, eu-2012-19-weee
sb_cutoff_disclosureall foreground and upstream inventoryDo not omit a material, component, hazardous substance, energy input, direct release or waste stream merely because its mass is small when it may materially affect results, safety, toxicity, scarcity or end-of-life treatment. Every applied cut-off and its effect must be disclosed.pep-ecopassport-pcr-ed4-2021
Allocation rules · 4
Rule IDApplies toRuleSource IDs
alloc_avoid_where_possiblemulti-output foreground operationsSubdivide processes or use direct metering and physical tracking before applying allocation. Document the unallocated inventory and the reason subdivision is not feasible.pep-ecopassport-pcr-ed4-2021
alloc_coproduct_massprocess that produces more than one valuable co-productAllocate residual shared burdens by the mass of output co-products when direct assignment or subdivision is not feasible, and disclose output masses and the calculation.pep-ecopassport-psr-0014-2023
alloc_recycling_boundaryproduction scrap and end-of-life recoveryAssign collection and treatment to the stage that generates the waste through the declared end-of-waste point. Do not subtract avoided virgin-material or energy burdens from the foreground inventory; report optional benefits beyond the boundary separately.pep-ecopassport-pcr-ed4-2021, pep-ecopassport-psr-0014-2023
alloc_rework_and_rejectsreworked and rejected luminaires or componentsAssign added materials, energy and treatment to the production that generated the rework or reject. Returned supplier parts must be reconciled and must not be counted both as consumed input and on-site waste.pep-ecopassport-pcr-ed4-2021
Validation rules · 10
Rule IDApplies toRuleSource IDs
val_reference_identityreference flowThe reference product flow UUID must be 3253c9d6-cf81-41e6-8997-f59f437c3f2d, flow type Product flow, CPC 46533, state code 100, with Mass property 93a60a56-a3c8-11da-a746-0800200b9a66, Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66, and kg.
val_complete_luminaireproduct identity and BOMReject datasets for a single LED die, package, module, lamp, driver, power supply, optical part, housing, generic lamp part, non-LED fitting, or an incomplete configuration.pep-ecopassport-psr-0014-2023, eu-2019-2020-light-sources
val_reference_amountreference outputThe normalized output must equal 1 kg net complete luminaire excluding packaging, and the corresponding product count must be declared.pep-ecopassport-pcr-ed4-2021
val_required_qualifiersdataset metadataAll required qualifiers in the reference-flow table must be present and traceable to the declared product configuration and production period.pep-ecopassport-psr-0014-2023
val_process_coveragemanufacturer-gate datasetComponent and subassembly supply or fabrication, assembly and finishing, testing and rework, final packaging, production wastes, direct releases and upstream datasets must be covered or explicitly documented as not applicable without hiding a supplied component.pep-ecopassport-pcr-ed4-2021, pep-ecopassport-psr-0014-2023
val_performance_evidenceoutgoing flux, power and lifetimeOutgoing flux and power must be for the complete luminaire at recorded reference control settings; lifetime and replaceability must be supported and must distinguish luminaire, LED source and control gear.pep-ecopassport-psr-0014-2023, iec-60598-1-2024, eu-2019-2020-light-sources
val_mass_balanceproduct, component, packaging and waste recordsProduct and packaging mass balances must reconcile for aligned periods. Packaging must not be included in the product reference mass, and supplier returns or rework must not be double counted.pep-ecopassport-pcr-ed4-2021
val_allocationshared facilities and co-productsEvery allocated flow must identify the unallocated total, allocation driver and receiving outputs. Residual co-product allocation must use output mass unless a reviewed direct assignment or subdivision is documented.pep-ecopassport-psr-0014-2023
val_lifecycle_claimlifecyclemodel or lighting-service resultA claim covering the lighting service or cradle-to-grave result must include distribution, installation, use electricity, maintenance and replacements, and end-of-life; it must not present the 1 kg manufacturer-gate dataset alone as a full lifecycle result.pep-ecopassport-psr-0014-2023, eu-2012-19-weee
val_evidence_and_estimatesquantitative and source recordsReject unsupported fixed values, unlabelled estimates, missing source references for external rules, or reasoned estimates presented as final evidence.pep-ecopassport-pcr-ed4-2021
Processes and inputs/outputs · 6
Process IDProcess nameInput flowsOutput flows
component_and_subassembly_supplyComponent and Subassembly Supply or Fabrication23
luminaire_assemblyLuminaire Assembly, Wiring and Finishing32
functional_safety_photometric_testingFunctional, Safety, Electrical and Photometric Testing22
final_packagingFinal Inspection and Packaging22
distribution_installation_use_maintenanceDistribution, Installation, Use and Maintenance Scenario22
end_of_life_treatmentEnd-of-Life Collection and Treatment13

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page

1. Scope and Applicability2. Product Category Identity3. Reference Flow4. Measurement and Unit Rules5. System BoundaryBoundary Abstraction6. Process Inventory StructureProcess MapProcess: Component and Subassembly Supply or Fabrication (component_and_subassembly_supply)InputsProduct flowsSupplier-traceable bill of materials and component lots (bom_component_inputs)Component fabrication energy (component_fabrication_energy)OutputsProduct flowsAccepted component and subassembly set (accepted_component_set)Waste flowsComponent fabrication scrap and rejects (component_scrap_rejects)Elementary flowsDirect component-fabrication releases (component_direct_releases)Process: Luminaire Assembly, Wiring and Finishing (luminaire_assembly)InputsProduct flowsAccepted structure, optical, LED and control components (assembly_component_inputs)Assembly auxiliaries and consumables (assembly_auxiliaries)Assembly and finishing energy (assembly_energy)OutputsProduct flowsAssembled complete LED luminaire before final testing (assembled_luminaire)Waste flowsAssembly scrap, rejects and cleaning waste (assembly_waste)Process: Functional, Safety, Electrical and Photometric Testing (functional_safety_photometric_testing)InputsProduct flowsAssembled luminaire entering test (luminaire_entering_test)Test electricity (test_electricity)OutputsProduct flowsConforming tested complete LED luminaire (conforming_tested_luminaire)Waste flowsTest rejects and failed components (test_rejects)Process: Final Inspection and Packaging (final_packaging)InputsProduct flowsConforming tested luminaire entering packaging (tested_luminaire_for_packaging)Primary and secondary packaging (packaging_materials)OutputsProduct flowsComplete finished LED luminaire at manufacturer gate (finished_led_luminaire)Waste flowsPackaging operation waste (packaging_waste)Process: Distribution, Installation, Use and Maintenance Scenario (distribution_installation_use_maintenance)InputsProduct flowsFinished luminaire and installation items (installed_luminaire_inputs)Use electricity and replacement components (use_electricity_replacements)OutputsProduct flowsDocumented lighting service and used luminaire (lighting_service_and_used_luminaire)Waste flowsInstallation and maintenance wastes (installation_maintenance_waste)Process: End-of-Life Collection and Treatment (end_of_life_treatment)InputsWaste flowsUsed complete luminaire and replaced electrical parts (used_luminaire_weee_input)OutputsProduct flowsRecovered material outputs (recovered_material_outputs)Waste flowsFinal treatment residues (end_of_life_residues)Elementary flowsDirect treatment releases (end_of_life_direct_releases)7. Allocation and Co-product Handling8. Foreground Data Collection, Calculation, and Quality RulesData Collection ProtocolsCalculation RulesData Quality Requirements9. Validation Rules10. Published Dataset Profile11. Data Sources