TianGong PCR产品类别规则

Boards, consoles, cabinets and other bases, equipped with electrical switching etc. apparatus, for a voltage not exceeding 1,000 V

Boards, consoles, cabinets and other bases, equipped with electrical switching etc. apparatus, for a voltage not exceeding 1,000 V: This PCR governs foreground data…

Lifecycle status
Candidate
Content maturity
Authored methodology
Current version
No published version
Readiness
Review required
Last updated

Methodology and translation states come from the source record; publishing this website does not change their review status.

Content languages

zh-CN · Aligned
Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:46213 · exact

Source

1. Scope and Applicability

This PCR governs foreground data packages for complete low-voltage boards, consoles, cabinets and other equipped bases that switch, protect, control or distribute electricity at a declared rated voltage not exceeding 1,000 V. It covers fixed or movable, enclosed or open assemblies for industrial, commercial, infrastructure, photovoltaic, energy-storage interconnection and residential applications when the delivered product is a complete equipped assembly.

The data package must describe the actual configuration. A bare enclosure, one switching device, one part, or one residential distribution board must not be used as a proxy for this whole heterogeneous category. The CPC voltage ceiling remains 1,000 V even where a referenced technical standard has a wider DC scope.

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.metal-products-machinery-and-equipment.electrical-machinery-and-apparatus.boards-consoles-cabinets-and-other-bases-equipped-with-electrical-switching-etc-apparat-8d49dcd5
classification_refsCPC 3.0: 46213 (exact)
covered_productsComplete boards, consoles, switchboards, panelboards, control cabinets and other bases equipped with switching, protection, measurement or control apparatus for declared rated voltage not exceeding 1,000 V; includes declared photovoltaic and energy-storage interconnection configurations.
excluded_productsEmpty enclosures before apparatus is installed; individual switching, protection or connection apparatus; parts supplied separately; assemblies rated above 1,000 V; batteries, converters, inverters, transformers or external cooling equipment that are not part of the delivered equipped assembly.
representative_productNo category-wide default configuration. Representativeness is model- and application-specific and must be established from the declared electrical ratings, configuration, materials, protection/control functions, enclosure and operating conditions.
production_routePurchased or in-house fabricated enclosure and busbars; procurement of switching/protection/control devices and auxiliaries; mechanical assembly; busbar and internal wiring; programming where applicable; inspection and factory testing; packaging and dispatch.
market_stateComplete factory-tested assembly at the declared dispatch gate, including installed apparatus, internal conductors, mandatory accessories and separately quantified delivery packaging.

3. Reference Flow

FieldValue
WhatA complete, factory-tested low-voltage equipped assembly providing its declared switching, protection, control and/or distribution functions.
How muchThe mass corresponding to one declared delivered assembly, reported through a 1 kg reference amount.
How wellThe declared rated voltage and current, short-circuit capability, protection/control configuration, IP rating, cooling method and application.
How long or cycleOne declared reference service life and operating scenario; no category-wide lifetime or load profile is assumed.
reference_flow_linkThe functional unit is linked to the total net kg of the complete assembly; the data package must state kg per delivered assembly and scale the 1 kg reference result to the declared unit.
FieldValue
Reference amount1 kg
Reference product flowBoards, consoles, cabinets and other bases, equipped with electrical switching etc. apparatus, for electric control or the distribution of electricity, for a voltage not exceeding 1000 V 961bc3fa-a52f-47fe-afc0-0abac92f5fd1
Reference flow propertyMass 93a60a56-a3c8-11da-a746-0800200b9a66
Reference unit groupUnits of mass 93a60a57-a4c8-11da-a746-0800200c9a66
Reference unitkg
Required qualifiersmodel and application; AC or DC; rated voltage; rated assembly current and relevant circuit currents; declared short-circuit withstand, making or breaking ratings; indoor or outdoor use; enclosure construction and material masses; busbar material and mass; installed switching, protection, control, metering and communication configuration; IP rating; cooling method and auxiliary power; net assembly mass; delivery accessories and packaging boundary; reference service life; operating/load profile when use is modelled; production geography, technology and period; applicable verification or factory-test basis

When constructing a foreground data package, every item listed in Required qualifiers must be declared in dataset metadata, process notes, reference flow comment, product description, test documentation or an equivalent field. Missing qualifiers make the reference flow definition incomplete.

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
reference_massreference productMass 93a60a56-a3c8-11da-a746-0800200b9a66kgReport the net mass of the complete equipped assembly and the conversion between one delivered assembly and the 1 kg reference amount.
material_massenclosure, busbars, installed devices, internal wiring, auxiliaries and accessoriesMass 93a60a56-a3c8-11da-a746-0800200b9a66kgRecord component and material masses on a consistent dry, net-product basis; record packaging separately.
factory_energyfabrication, assembly and testing energyEnergykWhUse metered or invoice-reconciled energy and state the allocation to the declared model and production period.
use_energyload losses, auxiliary controls and active cooling when use is in scopeEnergykWhCalculate from measured or technically calculated losses and the declared load/time scenario; do not apply a category default.
service_lifereference service life and replacementsTimeyearDeclare the product-specific service life, basis, maintenance and component replacement scenario without treating a source-product lifetime as a category default.

5. System Boundary

The foreground manufacturing boundary begins when purchased materials, fabricated parts and apparatus are received at the assembly site and ends with the complete tested assembly and its delivery packaging at the declared dispatch gate. Upstream production of purchased inputs is linked through separate datasets. Distribution, installation, operation, maintenance and end-of-life are separate scenario modules unless the study explicitly brings them into scope.

rule_idApplies toRulesource_ids
boundary_complete_assemblyproduct identityInclude the enclosure or equipped base, busbars, installed switching/protection/control apparatus, internal wiring, auxiliaries, mandatory accessories, factory testing and separately quantified delivery packaging that form the declared delivered assembly.iec-61439-1-2020; iec-61439-2-2020; pep-psr-0005-ed3-1
boundary_factory_gateforeground manufacturingInclude site-controlled fabrication, finishing, assembly, wiring, programming, inspection, testing, rework, waste handling and packaging through the dispatch gate; disclose which fabrication steps are purchased rather than site-controlled.pep-psr-0005-ed3-1; abb-enviline-ess750-epd-2023
boundary_upstream_inputspurchased inputsLink purchased enclosure parts, busbars, devices, electronics, cables, auxiliaries, coatings and packaging to geographically and technologically appropriate upstream datasets; do not replace them with an unqualified whole-category proxy.pep-psr-0005-ed3-1
boundary_downstream_scenarioslife-cycle extensionsKeep distribution, installation, operation, maintenance, replacements and end-of-life outside the factory-gate foreground result unless explicitly included; when included, report each module separately with product-specific scenarios.pep-psr-0005-ed3-1; abb-enviline-ess750-epd-2023
boundary_category_exclusionscategory applicabilityReject empty enclosures, single apparatus and assemblies above the CPC voltage ceiling; a residential distribution board may represent only its declared subtype, not the entire category.un-cpc-v3-46213; iec-62208-2023; iec-61439-3-2024

Boundary Abstraction

FieldValue
declared_starting_conditionPurchased materials, parts, apparatus and subassemblies accepted at the declared assembly site, with supplier, geography, technology and mass records.
starting_condition_roleDisclosed foreground product inputs linked to upstream datasets.
product_classification_scopeComplete equipped assemblies within CPC 3.0 code 46213 and rated not above 1,000 V.
recursive_input_ruleA purchased input already classified as CPC 46213 remains an explicit same-category product input with its own mass, configuration, supplier and upstream dataset; it is not recursively expanded or silently merged with the reference output.
upstream_dataset_requirementUse input-specific datasets matching material or apparatus identity, production geography, technology and period; disclose proxies and data gaps.
disclosureState the dispatch gate, included accessories and packaging, purchased versus in-house fabrication, excluded life-cycle modules, and any same-category subassembly input.

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
fabrication_finishingEnclosure and busbar fabrication and finishingconditionalInclude when sheet-metal work, busbar processing or surface finishing is controlled by the reporting site.foreground unit processkg accepted fabricated parts
assembly_testingMechanical/electrical assembly and factory testingrequiredAlways include for a complete equipped assembly.foreground unit processkg complete tested assembly
packaging_dispatchDelivery packaging and dispatch preparationrequiredAlways include; report zero only with evidence of no delivery packaging.foreground unit processkg reference product at dispatch gate
use_operationOperation, cooling and maintenance scenarioexcluded_by_defaultInclude only for an explicitly declared cradle-to-grave or use-stage result.scenario processone declared assembly over declared service life

Process: Enclosure and Busbar Fabrication and Finishing (fabrication_finishing)

Inputs

Product flows
Fabrication materials and treatments (fabrication_materials)

Record sheet or structural metal, copper or aluminium conductor stock, coatings, chemicals and other inputs actually consumed by site-controlled fabrication.

  • Selected flow: Route-specific fabrication materials and treatment inputs
  • Flow property / unit: Mass / kg
  • Amount rule: Accepted input mass from purchasing, stores and batch records, by material and grade
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per kg accepted fabricated parts
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_fabrication_materials
  • Sources: pep-psr-0005-ed3-1
Fabrication energy (fabrication_energy)

Record metered electricity and fuels for cutting, punching, bending, joining, busbar processing and finishing.

  • Selected flow: Site-specific electricity and fuel inputs
  • Flow property / unit: Energy / kWh or fuel-specific unit
  • Amount rule: Metered use allocated to the declared production lot
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per kg accepted fabricated parts
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_fabrication_energy
  • Sources: pep-psr-0005-ed3-1
Waste flows
Elementary flows

Outputs

Product flows
Accepted fabricated enclosure and busbars (fabricated_parts)

Record accepted parts transferred to assembly; keep enclosure steel or aluminium and copper or aluminium busbar masses separately identifiable.

  • Selected flow: Fabricated enclosure, base and busbar subassembly
  • Flow property / unit: Mass / kg
  • Amount rule: Accepted mass transferred to assembly
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per fabrication batch
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_fabrication_materials
  • Sources: iec-61439-1-2020
Waste flows
Fabrication scrap and treatment waste (fabrication_waste)

Record metal scrap, spent treatment materials and other process waste by material and actual destination.

  • Selected flow: Route-specific fabrication waste
  • Flow property / unit: Mass / kg
  • Amount rule: Weighed waste by type and treatment destination
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per kg accepted fabricated parts
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_fabrication_waste
  • Sources: pep-psr-0005-ed3-1
Elementary flows
Direct fabrication and finishing releases (direct_fabrication_releases)

When site-controlled finishing produces direct releases, record measured or mass-balance-derived air and water emissions individually; do not represent treatment waste as an elementary flow.

  • Selected flow: Substance-specific direct air or water release
  • Flow property / unit: Mass / kg
  • Amount rule: Measured release or documented material balance for the declared fabrication batch
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per kg accepted fabricated parts
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_direct_releases
  • Sources: pep-psr-0005-ed3-1

Process: Mechanical/Electrical Assembly and Factory Testing (assembly_testing)

Inputs

Product flows
Installed bill of materials (installed_bom)

Record the mass and quantity of the enclosure/base, busbars, switching and protection devices, control and metering electronics, communication devices, internal wires and connectors, insulation, auxiliaries, active-cooling equipment, fasteners and mandatory accessories by part and material.

  • Selected flow: Configuration-specific installed components and materials
  • Flow property / unit: Mass / kg
  • Amount rule: Net installed mass reconciled from the as-built bill of materials, part weights and measured assembly mass
  • Value mode: Calculated value (calculated_value)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per kg complete tested assembly
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_assembly_bom
  • Sources: pep-psr-0005-ed3-1; abb-enviline-ess750-epd-2023
Assembly and test energy (assembly_test_energy)

Record electricity and other energy for assembly, wiring, programming, inspection, testing and rework.

  • Selected flow: Site-specific assembly and test energy
  • Flow property / unit: Energy / kWh
  • Amount rule: Metered or invoice-reconciled energy allocated to the declared model and production period
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per kg complete tested assembly
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_assembly_energy
  • Sources: pep-psr-0005-ed3-1
Waste flows
Elementary flows

Outputs

Product flows
Complete tested assembly (tested_assembly)

Record the configured assembly that has passed the declared factory inspection and verification basis.

  • Selected flow: Complete factory-tested low-voltage equipped assembly
  • Flow property / unit: Mass / kg
  • Amount rule: Measured net assembly mass excluding delivery packaging
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per completed assembly
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_configuration_test
  • Sources: iec-61439-1-2020; iec-61439-2-2020
Waste flows
Assembly rejects and production waste (assembly_waste)

Record rejected components, wire and busbar offcuts, damaged electronics, consumables and incoming packaging waste without netting recycling credits from the input inventory.

  • Selected flow: Configuration-specific assembly and test waste
  • Flow property / unit: Mass / kg
  • Amount rule: Weighed waste by type, cause and treatment destination
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per kg complete tested assembly
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_assembly_waste
  • Sources: pep-psr-0005-ed3-1
Elementary flows

Process: Delivery Packaging and Dispatch Preparation (packaging_dispatch)

Inputs

Product flows
Tested assembly input (tested_assembly_input)

Transfer the net tested assembly without changing its mass or configuration.

  • Selected flow: Complete factory-tested low-voltage equipped assembly
  • Flow property / unit: Mass / kg
  • Amount rule: Equal to the accepted output of assembly_testing
  • Value mode: Calculated value (calculated_value)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per delivered assembly
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_mass_reconciliation
  • Sources:
Delivery packaging and accessories (delivery_packaging)

Record wood, cardboard, paper, plastics, pallets, corrosion protection, restraints and separately delivered mandatory accessories by material and mass.

  • Selected flow: Delivery packaging and separately delivered mandatory accessories
  • Flow property / unit: Mass / kg
  • Amount rule: Measured mass by packaging material and accessory
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per delivered assembly
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_packaging
  • Sources: pep-psr-0005-ed3-1; abb-enviline-ess750-epd-2023
Waste flows
Elementary flows

Outputs

Product flows
Reference product at dispatch gate (reference_product)

Output the complete assembly at the declared gate. Packaging mass is linked but excluded from the 1 kg net-product reference amount.

  • Selected flow: Boards, consoles, cabinets and other bases, equipped with electrical switching etc. apparatus, for electric control or the distribution of electricity, for a voltage not exceeding 1000 V 961bc3fa-a52f-47fe-afc0-0abac92f5fd1
  • Flow property / unit: Mass / kg
  • Amount rule: 1 kg net complete assembly; state kg and packaging kg per delivered assembly
  • Value mode: Calculated value (calculated_value)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: 1 kg reference product at dispatch gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_mass_reconciliation
  • Sources:
Waste flows
Elementary flows

Process: Operation, Cooling and Maintenance Scenario (use_operation)

Inputs

Product flows
Operational electricity and replacements (use_energy_replacements)

When a use-stage result is requested, record losses of conductors and installed apparatus, auxiliary/control power, active cooling, declared maintenance and replacements for the actual load and lifetime scenario.

  • Selected flow: Scenario-specific electricity, maintenance materials and replacement components
  • Flow property / unit: Energy / kWh and Mass / kg
  • Amount rule: Calculated from declared loss measurements or technical calculations, auxiliary/cooling power, operating profile, service life and replacement records
  • Value mode: Calculated value (calculated_value)
  • Specificity: Scenario-specific (scenario_specific)
  • Normalization basis: per declared assembly over declared reference service life
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_use_scenario
  • Sources: pep-psr-0005-ed3-1
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Elementary flows

7. Allocation and Co-product Handling

rule_idApplies toRulesource_ids
allocation_subdivision_firstall foreground processesSubdivide fabrication, assembly, testing and packaging by line, batch or model before allocating shared burdens.pep-psr-0005-ed3-1
allocation_physical_drivershared energy, consumables and wasteUse direct metering, machine time, tested-unit count, processed material mass or another documented causal physical driver; use product mass only when it represents the causal relationship.pep-psr-0005-ed3-1
allocation_economic_exceptionresidual shared burdensEconomic allocation is not a default; use it only when subdivision and causal physical allocation are infeasible, and disclose the values, period, sensitivity and reason.pep-psr-0005-ed3-1
allocation_recycling_separationscrap, recycling and recoveryRecord waste destinations and any recycling or recovery model separately; do not subtract anticipated recycling benefits from virgin or recycled input quantities and do not double count recovered-material credits.pep-psr-0005-ed3-1

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_fabrication_materialsfabrication_finishingfabrication materials and accepted partsfabrication BOM and purchasing/stores recordmodel; part number; supplier; material/grade; quantity; unit mass; input mass; accepted-part mass; enclosure mass; busbar mass; recycled-content claimReconcile controlled fabrication BOM, drawings, scales and supplier declarations to the accepted batch.kg, itemeach model/revision and representative fabrication batchdeclared production periodeach reporting site and outsourced fabricatorSum input and accepted mass by material and grade; keep enclosure and busbar materials separate.approved fabrication BOM; weighing record; supplier declaration
cp_assembly_bomassembly_testinginstalled BOMas-built BOM and component recordmodel; part number; supplier; function; material; quantity; unit mass; installed mass; enclosure mass; busbar mass; device/electronics massReconcile controlled BOM, drawings, part weights and scale records to the as-built unit.kg, itemeach model/revision and representative production lotdeclared production periodeach reporting assembly siteSum installed mass by material and functional group; keep enclosure, busbars, devices, electronics, wires, cooling and accessories separate.approved BOM revision; weighing record; supplier declaration
cp_fabrication_energyfabrication_finishingfabrication energymeter, submeter, equipment log or invoicemeter boundary; start/end reading; energy carrier; fabrication activity; operating time; model; lot; accepted output mass; allocation driverPrefer process submetering; reconcile with site invoices and fabrication records.kWh or carrier-specific uniteach lot or no less frequently than the available meter/invoice periodrepresentative declared fabrication periodeach reporting fabrication siteSubtract unrelated loads and allocate remaining use to accepted fabricated-part output with the rule in section 7.meter calibration/status; invoice reconciliation; production log
cp_assembly_energyassembly_testingassembly and testing energymeter, submeter, equipment log or invoicemeter boundary; start/end reading; energy carrier; assembly/test activity; operating time; model; lot; tested output mass; allocation driverPrefer process submetering; reconcile with site invoices and assembly/test records.kWh or carrier-specific uniteach lot or no less frequently than the available meter/invoice periodrepresentative declared assembly periodeach reporting assembly siteSubtract unrelated loads and allocate remaining use to complete tested output with the rule in section 7.meter calibration/status; invoice reconciliation; production log
cp_fabrication_wastefabrication_finishingfabrication wastescale ticket and waste transfer recordfabrication activity; material; hazard class; gross/tare/net mass; destination; treatment; date; lotReconcile fabrication waste logs with transporter or treatment records.kgeach shipment and fabrication periodsame period as fabrication inventoryeach reporting fabrication siteSum by material and actual treatment destination; do not net against inputs.scale ticket; transfer note; treatment evidence
cp_assembly_wasteassembly_testingassembly and testing wastescale ticket and waste transfer recordassembly/test activity; material; hazard class; gross/tare/net mass; destination; treatment; date; lotReconcile assembly/test waste logs with transporter or treatment records.kgeach shipment and assembly periodsame period as assembly inventoryeach reporting assembly siteSum by material and actual treatment destination; do not net against inputs.scale ticket; transfer note; treatment evidence
cp_direct_releasesfabrication_finishingdirect air and water releasesstack/wastewater measurement or material-balance recordsubstance; compartment; measurement boundary; concentration; volume or mass; batch; method; dateUse site measurement where available; otherwise use a documented input-output material balance without converting waste transfers into emissions.kgeach monitored period or fabrication batchsame period as fabrication inventoryeach reporting finishing siteSum each substance and compartment separately and normalize to accepted fabricated-part output.laboratory or meter record; calculation and balance closure
cp_configuration_testassembly_testingratings, configuration and tested assemblyapproved design, nameplate and test recordmodel; serial/lot; AC/DC; rated voltage/current; circuit ratings; short-circuit ratings; IP; enclosure/busbar materials; protection/control list; cooling; auxiliary power; dimensions; net mass; test basis/resultExtract from controlled engineering and factory-test records and reconcile to the shipped configuration.declared engineering units and kgeach model/revision and tested lotcurrent declared model and production periodeach reporting siteDo not average unlike configurations unless the product mix and weighting are reported.approved drawing; nameplate; design verification; routine/factory test record
cp_packagingpackaging_dispatchdelivery packaging and accessoriespacking specification and weighing recordpackaging material; quantity; mass; reusable status; accessory identity/mass; destinationWeigh or calculate from controlled packing specifications and verify against shipments.kg per assemblyeach packing design/revision and representative shipmentdeclared shipping periodeach dispatch siteSum by packaging material; keep packaging and separately delivered accessories distinct from net product mass.packing list; scale record; packaging specification
cp_mass_reconciliationpackaging_dispatchmass balance and reference outputBOM, scale and transfer recordinstalled material mass; net tested mass; accessory mass; packaging mass; rework/reject mass; delivered massReconcile as-built BOM and process transfers to calibrated scale records.kgeach model/revision and representative lotsame period as BOM and production dataeach reporting siteExplain all residual differences; do not force an unexplained residual into an unspecified material.signed reconciliation; calibration evidence; variance investigation
cp_use_scenariouse_operationuse losses, auxiliaries, cooling, life and replacementstype/routine test, engineering calculation, operating profile and maintenance recordload points; current; voltage; power loss; auxiliary/cooling power; hours by load; ambient condition; service life; maintenance; replacement type/count; grid geographyUse applicable-standard measurement, laboratory report, engineering calculation or manufacturer data and document the chosen scenario.W, kWh, h, year, item, kgeach declared use scenario and model revisiondeclared service lifedeclared application and geographyIntegrate losses and auxiliary/cooling demand over declared hours; keep replacement inventory explicit.test/calculation report; scenario justification; maintenance plan

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
calc_reference_scalingreference productreference result per assembly = result per kg × net kg per delivered assembly1 kg reference result; measured net assembly massresult per delivered assembly
calc_material_reconciliationcomplete assemblynet assembly mass = sum of installed enclosure/base, busbars, apparatus, electronics, wiring, auxiliaries, cooling, fasteners and mandatory accessory masses; investigate and disclose any residualas-built BOM; part weights; measured net massreconciled material inventory and residual disclosurepep-psr-0005-ed3-1
calc_factory_energy_intensityfabrication and assembly/testingallocated process energy per kg = process energy assigned to the declared model or lot ÷ accepted kg outputenergy record; production record; allocation driverkWh per kg process outputpep-psr-0005-ed3-1
calc_waste_intensityproduction wastewaste per kg = waste mass attributed to the declared process/model ÷ accepted kg process outputwaste records; accepted output masskg waste per kg output by type and destination
calc_use_energyoptional use stageuse energy = sum over declared load states of measured or calculated assembly loss × hours + auxiliary/control power × hours + active-cooling power × hours; add explicit replacement inventoriesloss data; auxiliary/cooling demand; load/time profile; life; replacementskWh and replacement inventory per declared assembly lifepep-psr-0005-ed3-1

Data Quality Requirements

requirement_idApplies toRequirementEvidence
dq_configurationproduct identityData must describe one declared model/configuration or a transparent production mix; all electrical, enclosure, busbar, protection/control, IP, cooling and delivery qualifiers must match it.controlled design, BOM, nameplate and test records
dq_mass_completenessmaterial inventoryReconcile installed material groups to measured net assembly mass and disclose the value and cause of every unresolved residual.signed mass reconciliation and variance investigation
dq_temporal_siteforeground dataUse a declared representative production period and identify every assembly, fabrication and dispatch site; disclose exceptional downtime, rework or product-mix effects.dated meters, invoices, production and shipment records
dq_upstream_matchpurchased inputsMatch upstream data to material/apparatus identity, geography, technology and time; disclose every proxy and why it is the closest available choice.supplier evidence, dataset metadata and proxy register
dq_use_scenariooptional use stageTie losses, auxiliary/cooling demand, load profile, service life, maintenance and replacements to the declared configuration; do not substitute a product-specific published scenario as a category default.test/calculation report and scenario justification
dq_source_traceabilityall calculated valuesPreserve source record identifiers, transformations, allocation drivers, units and reviewer-reproducible calculations.calculation workbook or controlled data pipeline with lineage

9. Validation Rules

rule_idApplies toRulesource_ids
validate_identity_voltageproduct identityConfirm the dataset is a complete equipped assembly in CPC 46213 and its declared rated voltage does not exceed 1,000 V; reject an empty enclosure, individual apparatus, part or higher-voltage assembly.un-cpc-v3-46213; iec-62208-2023
validate_reference_identityreference flowConfirm product flow 961bc3fa-a52f-47fe-afc0-0abac92f5fd1, Mass 93a60a56-a3c8-11da-a746-0800200b9a66, Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 and kg, without embedding dataset versions.
validate_qualifiersreference flowConfirm every required qualifier is present and consistent with the controlled design, nameplate, BOM and test record.iec-61439-1-2020; iec-61439-2-2020
validate_mass_balancematerial inventoryConfirm installed material groups reconcile to measured net product mass; flag and disclose every unexplained residual rather than inserting an unspecified default.pep-psr-0005-ed3-1
validate_process_boundaryforeground processesConfirm all site-controlled fabrication, assembly, testing, rework, waste handling and packaging are included and purchased processes are disclosed and linked upstream.pep-psr-0005-ed3-1
validate_energy_allocationfactory energyConfirm meter/invoice reconciliation, excluded unrelated loads and the documented physical allocation driver for the declared model and period.pep-psr-0005-ed3-1
validate_waste_destinationswasteConfirm production waste mass, type and actual destination are recorded without netting recycling credits from inputs.pep-psr-0005-ed3-1
validate_use_scenariooptional use stageWhen use is reported, confirm losses, auxiliary/control and cooling energy, load/time profile, service life, maintenance, replacements and grid geography are configuration-specific and separately disclosed.pep-psr-0005-ed3-1
validate_no_proxy_extrapolationrepresentativenessReject a claim that an empty cabinet, one switching device, one residential distribution board or one photovoltaic/energy-storage model represents the full category without a declared and weighted product mix.iec-62208-2023; iec-61439-3-2024; abb-enviline-ess750-epd-2023
validate_source_lineageall reported valuesConfirm every foreground value and calculation is linked to its collection record, unit, period, site and transformation; sources support rules only and are not used as unreviewed default quantities.

10. Published Dataset Profile

FieldValue
dataset_roleunit_process
downstream_usesecondary_dataset
allowed_useConfiguration-specific factory-gate datasets for complete CPC 46213 assemblies, and explicitly separated distribution, installation, use, maintenance and end-of-life scenario extensions.
excluded_useEmpty enclosures; individual devices or parts; assemblies above 1,000 V; unqualified category-average claims; extrapolation of one residential, photovoltaic or energy-storage assembly to the whole category.
required_metadataPCR id; CPC code; reference-flow UUIDs; model and application; AC/DC; rated voltage/current and short-circuit ratings; configuration; enclosure and busbar materials; protection/control functions; IP; cooling and auxiliary power; net mass; packaging/delivery boundary; service life; geography; technology; period; sites; allocation; scenario modules.
required_quality_disclosureBOM and mass reconciliation; foreground metering and allocation; waste destinations; upstream dataset matches and proxies; factory-test basis; product-mix weighting; optional use/lifetime/replacement assumptions; data gaps and reviewer-reproducible lineage.
update_triggerDesign or BOM revision; changed ratings, enclosure/busbar material, device/control configuration, IP or cooling; changed production route/site/energy mix; changed packaging/delivery boundary; changed service-life or use scenario; materially improved supplier or foreground evidence.

11. Data Sources

Source idTypeReferenceUsed for
un-cpc-v3-46213official_guidanceUnited Nations Statistics Division, Central Product Classification Version 3.0 Explanatory Notes, class 46213 and adjacent classes, https://unstats.un.org/UNSDWebsite/statcom/session_56/documents/BG-3o-Explanatory_Notes_of_the_Central_Product_Classification_Version3-E.pdf (retrieved 2026-08-08)category identity, voltage ceiling and exclusions
iec-61439-1-2020standardIEC 61439-1:2020, Low-voltage switchgear and controlgear assemblies - Part 1: General rules, https://webstore.iec.ch/en/publication/32338 (retrieved 2026-08-08)assembly characteristics, construction and verification qualifiers
iec-61439-2-2020standardIEC 61439-2:2020, Low-voltage switchgear and controlgear assemblies - Part 2: Power switchgear and controlgear assemblies, https://webstore.iec.ch/en/publication/30043 (retrieved 2026-08-08)assembly scope, applications, IP and active-cooling declarations
iec-61439-3-2024standardIEC 61439-3:2024, Distribution boards intended to be operated by ordinary persons, https://webstore.iec.ch/en/publication/68496 (retrieved 2026-08-08)residential distribution-board subtype boundary
iec-62208-2023standardIEC 62208:2023, Empty enclosures for low-voltage switchgear and controlgear assemblies - General requirements, https://webstore.iec.ch/en/publication/67906 (retrieved 2026-08-08)exclusion of empty enclosures
pep-psr-0005-ed3-1official_guidancePEP ecopassport, PSR-0005-ed3.1-EN-2023 06 06, Specific Rules for Electrical Switchgear and Control Gear Solutions, https://register.pep-ecopassport.org/documents/public/PSR-0005-EN (retrieved 2026-08-08)boundary, inventory completeness, allocation, use-energy method and data quality
abb-enviline-ess750-epd-2023datasetABB, Enviline ESS 750 Energy Storage System, verified EPD NEPD-4756-4011, https://www.epd-norge.no/getfile.php/1342230-1691345766/EPDer/Byggevarer/NEPD-4756-4011_Enviline----ESS-750-----Energy-Storage-System.pdf (retrieved 2026-08-08)non-default evidence for material/process decomposition and product-specific scenario variability

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 6
Rule IDApplies toRuleSource IDs
system_boundary_rule_1foreground_system_boundaryThe foreground manufacturing boundary begins when purchased materials, fabricated parts and apparatus are received at the assembly site and ends with the complete tested assembly and its delivery packaging at the declared dispatch gate. Upstream production of purchased inputs is linked through separate datasets. Distribution, installation, operation, maintenance and end-of-life are separate scenario modules unless the study explicitly brings them into scope.
boundary_complete_assemblyproduct identityInclude the enclosure or equipped base, busbars, installed switching/protection/control apparatus, internal wiring, auxiliaries, mandatory accessories, factory testing and separately quantified delivery packaging that form the declared delivered assembly.iec-61439-1-2020, iec-61439-2-2020, pep-psr-0005-ed3-1
boundary_factory_gateforeground manufacturingInclude site-controlled fabrication, finishing, assembly, wiring, programming, inspection, testing, rework, waste handling and packaging through the dispatch gate; disclose which fabrication steps are purchased rather than site-controlled.pep-psr-0005-ed3-1, abb-enviline-ess750-epd-2023
boundary_upstream_inputspurchased inputsLink purchased enclosure parts, busbars, devices, electronics, cables, auxiliaries, coatings and packaging to geographically and technologically appropriate upstream datasets; do not replace them with an unqualified whole-category proxy.pep-psr-0005-ed3-1
boundary_downstream_scenarioslife-cycle extensionsKeep distribution, installation, operation, maintenance, replacements and end-of-life outside the factory-gate foreground result unless explicitly included; when included, report each module separately with product-specific scenarios.pep-psr-0005-ed3-1, abb-enviline-ess750-epd-2023
boundary_category_exclusionscategory applicabilityReject empty enclosures, single apparatus and assemblies above the CPC voltage ceiling; a residential distribution board may represent only its declared subtype, not the entire category.un-cpc-v3-46213, iec-62208-2023, iec-61439-3-2024
Allocation rules · 4
Rule IDApplies toRuleSource IDs
allocation_subdivision_firstall foreground processesSubdivide fabrication, assembly, testing and packaging by line, batch or model before allocating shared burdens.pep-psr-0005-ed3-1
allocation_physical_drivershared energy, consumables and wasteUse direct metering, machine time, tested-unit count, processed material mass or another documented causal physical driver; use product mass only when it represents the causal relationship.pep-psr-0005-ed3-1
allocation_economic_exceptionresidual shared burdensEconomic allocation is not a default; use it only when subdivision and causal physical allocation are infeasible, and disclose the values, period, sensitivity and reason.pep-psr-0005-ed3-1
allocation_recycling_separationscrap, recycling and recoveryRecord waste destinations and any recycling or recovery model separately; do not subtract anticipated recycling benefits from virgin or recycled input quantities and do not double count recovered-material credits.pep-psr-0005-ed3-1
Validation rules · 10
Rule IDApplies toRuleSource IDs
validate_identity_voltageproduct identityConfirm the dataset is a complete equipped assembly in CPC 46213 and its declared rated voltage does not exceed 1,000 V; reject an empty enclosure, individual apparatus, part or higher-voltage assembly.un-cpc-v3-46213, iec-62208-2023
validate_reference_identityreference flowConfirm product flow 961bc3fa-a52f-47fe-afc0-0abac92f5fd1, Mass 93a60a56-a3c8-11da-a746-0800200b9a66, Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66 and kg, without embedding dataset versions.
validate_qualifiersreference flowConfirm every required qualifier is present and consistent with the controlled design, nameplate, BOM and test record.iec-61439-1-2020, iec-61439-2-2020
validate_mass_balancematerial inventoryConfirm installed material groups reconcile to measured net product mass; flag and disclose every unexplained residual rather than inserting an unspecified default.pep-psr-0005-ed3-1
validate_process_boundaryforeground processesConfirm all site-controlled fabrication, assembly, testing, rework, waste handling and packaging are included and purchased processes are disclosed and linked upstream.pep-psr-0005-ed3-1
validate_energy_allocationfactory energyConfirm meter/invoice reconciliation, excluded unrelated loads and the documented physical allocation driver for the declared model and period.pep-psr-0005-ed3-1
validate_waste_destinationswasteConfirm production waste mass, type and actual destination are recorded without netting recycling credits from inputs.pep-psr-0005-ed3-1
validate_use_scenariooptional use stageWhen use is reported, confirm losses, auxiliary/control and cooling energy, load/time profile, service life, maintenance, replacements and grid geography are configuration-specific and separately disclosed.pep-psr-0005-ed3-1
validate_no_proxy_extrapolationrepresentativenessReject a claim that an empty cabinet, one switching device, one residential distribution board or one photovoltaic/energy-storage model represents the full category without a declared and weighted product mix.iec-62208-2023, iec-61439-3-2024, abb-enviline-ess750-epd-2023
validate_source_lineageall reported valuesConfirm every foreground value and calculation is linked to its collection record, unit, period, site and transformation; sources support rules only and are not used as unreviewed default quantities.
Processes and inputs/outputs · 4
Process IDProcess nameInput flowsOutput flows
fabrication_finishingEnclosure and busbar fabrication and finishing23
assembly_testingMechanical/electrical assembly and factory testing22
packaging_dispatchDelivery packaging and dispatch preparation21
use_operationOperation, cooling and maintenance scenario10

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page

1. Scope and Applicability2. Product Category Identity3. Reference Flow4. Measurement and Unit Rules5. System BoundaryBoundary Abstraction6. Process Inventory StructureProcess MapProcess: Enclosure and Busbar Fabrication and Finishing (fabrication_finishing)InputsProduct flowsFabrication materials and treatments (fabrication_materials)Fabrication energy (fabrication_energy)Waste flowsElementary flowsOutputsProduct flowsAccepted fabricated enclosure and busbars (fabricated_parts)Waste flowsFabrication scrap and treatment waste (fabrication_waste)Elementary flowsDirect fabrication and finishing releases (direct_fabrication_releases)Process: Mechanical/Electrical Assembly and Factory Testing (assembly_testing)InputsProduct flowsInstalled bill of materials (installed_bom)Assembly and test energy (assembly_test_energy)Waste flowsElementary flowsOutputsProduct flowsComplete tested assembly (tested_assembly)Waste flowsAssembly rejects and production waste (assembly_waste)Elementary flowsProcess: Delivery Packaging and Dispatch Preparation (packaging_dispatch)InputsProduct flowsTested assembly input (tested_assembly_input)Delivery packaging and accessories (delivery_packaging)Waste flowsElementary flowsOutputsProduct flowsReference product at dispatch gate (reference_product)Waste flowsElementary flowsProcess: Operation, Cooling and Maintenance Scenario (use_operation)InputsProduct flowsOperational electricity and replacements (use_energy_replacements)Waste flowsElementary flowsOutputsProduct flowsWaste flowsElementary flows7. Allocation and Co-product Handling8. Foreground Data Collection, Calculation, and Quality RulesData Collection ProtocolsCalculation RulesData Quality Requirements9. Validation Rules10. Published Dataset Profile11. Data Sources