TianGong PCR产品类别规则

Meat of horses and other equines, frozen · Process: Cleaning and disinfection (cleaning_and_disinfection)

Meat of horses and other equines, frozen · Process: Cleaning and disinfection (cleaning_and_disinfection): Process water crosses the cleaning and disinfection boundary…

Lifecycle status
Candidate
Content maturity
Authored methodology
Current version
No published version
Readiness
Review required
Last updated

Methodology and translation states come from the source record; publishing this website does not change their review status.

Content languages

zh-CN · Aligned
Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:21138 · exact

Source

Process: Cleaning and disinfection (cleaning_and_disinfection)

Inputs

Product flows
Cleaning and disinfection process water (cip_process_water)

Process water crosses the cleaning and disinfection boundary for equipment operation, washing, or hygiene duties assigned to this stage.

  • Selected flow: Process water
  • Flow property / unit: Volume / m3
  • Amount rule: Record the metered or reconciled volume consumed by this stage during the reporting period.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Cleaning and disinfection grid electricity (cip_electricity)

Grid electricity crosses the cleaning and disinfection boundary to operate equipment assigned to this stage.

  • Selected flow: Electricity, grid
  • Flow property / unit: Energy / kWh
  • Amount rule: Record the stage meter reading; when only a shared meter exists, allocate the measured total with a documented operating driver.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Cleaning and disinfection purchased steam (cip_purchased_steam)

Purchased steam crosses the cleaning and disinfection boundary when the facility supplies steam to this stage.

  • Selected flow: Purchased steam
  • Flow property / unit: Mass / kg
  • Amount rule: Record the metered or supplier-reconciled steam mass attributable to this stage; report zero only with evidence of absence.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Cleaning and disinfection purchased hot water (cip_purchased_hot_water)

Purchased hot water crosses the cleaning and disinfection boundary when hot water is supplied as a separately delivered utility.

  • Selected flow: Purchased hot water
  • Flow property / unit: Mass / kg
  • Amount rule: Record the delivered hot-water mass attributable to this stage from meters, delivery records, or a documented balance.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Cleaning and disinfection natural gas (cip_natural_gas)

Natural gas crosses the cleaning and disinfection boundary when directly combusted by equipment assigned to this stage.

  • Selected flow: Natural gas
  • Flow property / unit: Energy / MJ
  • Amount rule: Record fuel consumption and convert to energy using the declared metering and calorific-value basis.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Cleaning and disinfection diesel fuel (cip_diesel)

Diesel fuel crosses the cleaning and disinfection boundary when stationary or mobile equipment assigned to this stage consumes diesel on site.

  • Selected flow: Diesel fuel
  • Flow property / unit: Mass / kg
  • Amount rule: Record issued or metered diesel mass assigned to this stage and reconcile it to stock records.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Cleaning and disinfection liquefied petroleum gas (cip_lpg)

Liquefied petroleum gas crosses the cleaning and disinfection boundary when equipment assigned to this stage consumes it on site.

  • Selected flow: Liquefied petroleum gas
  • Flow property / unit: Mass / kg
  • Amount rule: Record delivered or issued LPG mass assigned to this stage and reconcile it to stock records.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Sodium hydroxide cleaning solution (cip_sodium_hydroxide)

Sodium hydroxide cleaning solution crosses the sanitation boundary only when a site record confirms its use.

  • Selected flow: Sodium hydroxide cleaning solution
  • Flow property / unit: Mass / kg solution
  • Amount rule: Record issued solution mass and concentration from stock, dosing, and batch records; report zero only with evidence of absence.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Nitric acid cleaning solution (cip_nitric_acid)

Nitric acid cleaning solution crosses the sanitation boundary only when a site record confirms its use.

  • Selected flow: Nitric acid cleaning solution
  • Flow property / unit: Mass / kg solution
  • Amount rule: Record issued solution mass and concentration from stock, dosing, and batch records; report zero only with evidence of absence.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Sodium hypochlorite disinfectant (cip_sodium_hypochlorite)

Sodium hypochlorite disinfectant crosses the sanitation boundary only when a site record confirms its use.

  • Selected flow: Sodium hypochlorite disinfectant
  • Flow property / unit: Mass / kg solution
  • Amount rule: Record issued solution mass and concentration from stock, dosing, and batch records; report zero only with evidence of absence.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Peracetic acid disinfectant (cip_peracetic_acid)

Peracetic acid disinfectant crosses the sanitation boundary only when a site record confirms its use.

  • Selected flow: Peracetic acid disinfectant
  • Flow property / unit: Mass / kg solution
  • Amount rule: Record issued solution mass and concentration from stock, dosing, and batch records; report zero only with evidence of absence.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Sanitation wastewater (cip_sanitation_wastewater)

Sanitation wastewater leaves cleaning and disinfection as one separately quantified liquid waste stream before treatment.

  • Selected flow: Sanitation wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Record metered discharge volume or calculate it from the documented sanitation water balance.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Elementary flows
Cleaning and disinfection fossil carbon dioxide emission (cip_carbon_dioxide_to_air)

Fossil carbon dioxide emission crosses from cleaning and disinfection equipment to air as one separately reported elementary exchange.

  • Selected flow: Carbon dioxide, fossil, to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate from collected stage fuel records and the dataset's disclosed measurement or emission-factor basis; assign no PCR default.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Cleaning and disinfection nitrogen oxides emission (cip_nitrogen_oxides_to_air)

Nitrogen oxides emission crosses from cleaning and disinfection equipment to air as one separately reported elementary exchange.

  • Selected flow: Nitrogen oxides to air
  • Flow property / unit: Mass / kg NO2-equivalent
  • Amount rule: Calculate from collected stage fuel records and the dataset's disclosed measurement or emission-factor basis; assign no PCR default.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Cleaning and disinfection sulfur dioxide emission (cip_sulfur_dioxide_to_air)

Sulfur dioxide emission crosses from cleaning and disinfection equipment to air as one separately reported elementary exchange.

  • Selected flow: Sulfur dioxide to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate from collected stage fuel records and the dataset's disclosed measurement or emission-factor basis; assign no PCR default.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Cleaning and disinfection fine particulate emission (cip_particulate_matter_to_air)

Fine particulate emission crosses from cleaning and disinfection equipment to air as one separately reported elementary exchange.

  • Selected flow: Particulate matter, <2.5 um, to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate from collected stage fuel records and the dataset's disclosed measurement or emission-factor basis; assign no PCR default.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_cleaning_disinfection_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef

Process: On-site wastewater treatment (onsite_wastewater_treatment)

Inputs

Product flows
On-site wastewater treatment process water (wwt_process_water)

Process water crosses the on-site wastewater treatment boundary for equipment operation, washing, or hygiene duties assigned to this stage.

  • Selected flow: Process water
  • Flow property / unit: Volume / m3
  • Amount rule: Record the metered or reconciled volume consumed by this stage during the reporting period.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
On-site wastewater treatment grid electricity (wwt_electricity)

Grid electricity crosses the on-site wastewater treatment boundary to operate equipment assigned to this stage.

  • Selected flow: Electricity, grid
  • Flow property / unit: Energy / kWh
  • Amount rule: Record the stage meter reading; when only a shared meter exists, allocate the measured total with a documented operating driver.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
On-site wastewater treatment purchased steam (wwt_purchased_steam)

Purchased steam crosses the on-site wastewater treatment boundary when the facility supplies steam to this stage.

  • Selected flow: Purchased steam
  • Flow property / unit: Mass / kg
  • Amount rule: Record the metered or supplier-reconciled steam mass attributable to this stage; report zero only with evidence of absence.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
On-site wastewater treatment purchased hot water (wwt_purchased_hot_water)

Purchased hot water crosses the on-site wastewater treatment boundary when hot water is supplied as a separately delivered utility.

  • Selected flow: Purchased hot water
  • Flow property / unit: Mass / kg
  • Amount rule: Record the delivered hot-water mass attributable to this stage from meters, delivery records, or a documented balance.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
On-site wastewater treatment natural gas (wwt_natural_gas)

Natural gas crosses the on-site wastewater treatment boundary when directly combusted by equipment assigned to this stage.

  • Selected flow: Natural gas
  • Flow property / unit: Energy / MJ
  • Amount rule: Record fuel consumption and convert to energy using the declared metering and calorific-value basis.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
On-site wastewater treatment diesel fuel (wwt_diesel)

Diesel fuel crosses the on-site wastewater treatment boundary when stationary or mobile equipment assigned to this stage consumes diesel on site.

  • Selected flow: Diesel fuel
  • Flow property / unit: Mass / kg
  • Amount rule: Record issued or metered diesel mass assigned to this stage and reconcile it to stock records.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
On-site wastewater treatment liquefied petroleum gas (wwt_lpg)

Liquefied petroleum gas crosses the on-site wastewater treatment boundary when equipment assigned to this stage consumes it on site.

  • Selected flow: Liquefied petroleum gas
  • Flow property / unit: Mass / kg
  • Amount rule: Record delivered or issued LPG mass assigned to this stage and reconcile it to stock records.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Ferric chloride treatment solution (wwt_ferric_chloride)

Ferric chloride solution crosses the wastewater-treatment boundary only when a dosing record confirms its use.

  • Selected flow: Ferric chloride solution
  • Flow property / unit: Mass / kg solution
  • Amount rule: Record dosed solution mass and concentration from treatment logs; report zero only with evidence of absence.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Polyacrylamide flocculant (wwt_polyacrylamide)

Polyacrylamide flocculant crosses the wastewater-treatment boundary only when a dosing record confirms its use.

  • Selected flow: Polyacrylamide flocculant
  • Flow property / unit: Mass / kg solution
  • Amount rule: Record dosed solution mass and concentration from treatment logs; report zero only with evidence of absence.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Waste flows
Lairage wash wastewater entering treatment (wwt_lairage_wash_wastewater)

Lairage wash wastewater enters on-site treatment as one separately reconciled waste input from its originating foreground stage.

  • Selected flow: Lairage wash wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Use the originating stage volume and reconcile it to the treatment inlet flow balance.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
High-organic-load slaughter wastewater entering treatment (wwt_high_organic_load_wastewater)

High-organic-load slaughter wastewater enters on-site treatment as one separately reconciled waste input from its originating foreground stage.

  • Selected flow: High-organic-load slaughter wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Use the originating stage volume and reconcile it to the treatment inlet flow balance.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Cutting-floor wash wastewater entering treatment (wwt_cutting_floor_wastewater)

Cutting-floor wash wastewater enters on-site treatment as one separately reconciled waste input from its originating foreground stage.

  • Selected flow: Cutting-floor wash wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Use the originating stage volume and reconcile it to the treatment inlet flow balance.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Freezer defrost wastewater entering treatment (wwt_freezer_defrost_wastewater)

Freezer defrost wastewater enters on-site treatment as one separately reconciled waste input from its originating foreground stage.

  • Selected flow: Freezer defrost wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Use the originating stage volume and reconcile it to the treatment inlet flow balance.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Packaging-area wash wastewater entering treatment (wwt_packaging_area_wastewater)

Packaging-area wash wastewater enters on-site treatment as one separately reconciled waste input from its originating foreground stage.

  • Selected flow: Packaging-area wash wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Use the originating stage volume and reconcile it to the treatment inlet flow balance.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Frozen-store defrost wastewater entering treatment (wwt_frozen_store_defrost_wastewater)

Frozen-store defrost wastewater enters on-site treatment as one separately reconciled waste input from its originating foreground stage.

  • Selected flow: Frozen-store defrost wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Use the originating stage volume and reconcile it to the treatment inlet flow balance.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Sanitation wastewater entering treatment (wwt_sanitation_wastewater)

Sanitation wastewater enters on-site treatment as one separately reconciled waste input from its originating foreground stage.

  • Selected flow: Sanitation wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Use the originating stage volume and reconcile it to the treatment inlet flow balance.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Elementary flows

Outputs

Product flows
Waste flows
Treated slaughterhouse wastewater (wwt_treated_wastewater)

Treated slaughterhouse wastewater leaves on-site treatment as one quantified water-carrier waste flow before discharge or further transfer.

  • Selected flow: Treated slaughterhouse wastewater
  • Flow property / unit: Volume / m3
  • Amount rule: Record final effluent flow-meter volume and discharge or transfer destination.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Slaughterhouse wastewater-treatment sludge (wwt_sludge)

Wastewater-treatment sludge leaves the treatment process as one separately weighed wet waste stream.

  • Selected flow: Slaughterhouse wastewater-treatment sludge
  • Flow property / unit: Mass / kg wet matter
  • Amount rule: Record dewatered wet mass and treatment destination from operating records.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Slaughterhouse wastewater screenings (wwt_screenings)

Screenings removed from slaughterhouse wastewater leave treatment as one separately weighed wet waste stream.

  • Selected flow: Slaughterhouse wastewater screenings
  • Flow property / unit: Mass / kg wet matter
  • Amount rule: Record dewatered wet mass and treatment destination from operating records.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Elementary flows
Chemical oxygen demand discharge (wwt_cod_to_water)

Chemical oxygen demand discharge crosses from the on-site treatment outlet to the receiving water compartment as one separately reported elementary exchange.

  • Selected flow: Chemical oxygen demand to water
  • Flow property / unit: Mass / kg O2-equivalent
  • Amount rule: Calculate discharged COD mass from matched effluent volume and laboratory concentration records after blank, unit, and time alignment checks.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Total nitrogen discharge (wwt_total_nitrogen_to_water)

Total nitrogen discharge crosses from the on-site treatment outlet to the receiving water compartment as one separately reported elementary exchange.

  • Selected flow: Total nitrogen to water
  • Flow property / unit: Mass / kg N
  • Amount rule: Calculate discharged total nitrogen mass from matched effluent volume and laboratory concentration records after blank, unit, and time alignment checks.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Total phosphorus discharge (wwt_total_phosphorus_to_water)

Total phosphorus discharge crosses from the on-site treatment outlet to the receiving water compartment as one separately reported elementary exchange.

  • Selected flow: Total phosphorus to water
  • Flow property / unit: Mass / kg P
  • Amount rule: Calculate discharged total phosphorus mass from matched effluent volume and laboratory concentration records after blank, unit, and time alignment checks.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
Total suspended solids discharge (wwt_total_suspended_solids_to_water)

Total suspended solids discharge crosses from the on-site treatment outlet to the receiving water compartment as one separately reported elementary exchange.

  • Selected flow: Total suspended solids to water
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate discharged total suspended solids mass from matched effluent volume and laboratory concentration records after blank, unit, and time alignment checks.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
On-site wastewater treatment fossil carbon dioxide emission (wwt_carbon_dioxide_to_air)

Fossil carbon dioxide emission crosses from on-site wastewater treatment equipment to air as one separately reported elementary exchange.

  • Selected flow: Carbon dioxide, fossil, to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate from collected stage fuel records and the dataset's disclosed measurement or emission-factor basis; assign no PCR default.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
On-site wastewater treatment nitrogen oxides emission (wwt_nitrogen_oxides_to_air)

Nitrogen oxides emission crosses from on-site wastewater treatment equipment to air as one separately reported elementary exchange.

  • Selected flow: Nitrogen oxides to air
  • Flow property / unit: Mass / kg NO2-equivalent
  • Amount rule: Calculate from collected stage fuel records and the dataset's disclosed measurement or emission-factor basis; assign no PCR default.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
On-site wastewater treatment sulfur dioxide emission (wwt_sulfur_dioxide_to_air)

Sulfur dioxide emission crosses from on-site wastewater treatment equipment to air as one separately reported elementary exchange.

  • Selected flow: Sulfur dioxide to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate from collected stage fuel records and the dataset's disclosed measurement or emission-factor basis; assign no PCR default.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
On-site wastewater treatment fine particulate emission (wwt_particulate_matter_to_air)

Fine particulate emission crosses from on-site wastewater treatment equipment to air as one separately reported elementary exchange.

  • Selected flow: Particulate matter, <2.5 um, to air
  • Flow property / unit: Mass / kg
  • Amount rule: Calculate from collected stage fuel records and the dataset's disclosed measurement or emission-factor basis; assign no PCR default.
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg net reference product using measured treated volume
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_onsite_wastewater_treatment_records
  • Sources: ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef

7. Allocation and Co-product Handling

rule_idApplies toRulesource_ids
alloc_subdivision_firstseparable_processesAvoid allocation first by subdividing metered operations and directly assigning stage utilities, packaging, chemicals, wastes, and emissions to the process output that causes them.eu-recommendation-2021-2279-pef
alloc_product_waste_statusall_non_reference_outputsClassify every blood, hide, organ, fat, bone, trimming, condemned-material, digestive-content, sludge, screening, and packaging output as a product, co-product, or waste from documented legal, technical, and destination evidence; do not infer saleable status.ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
alloc_physical_relationjoint_productsWhen subdivision cannot avoid burden sharing and a causal physical relation can be demonstrated, allocate the residual burden with that documented physical relation and report the driver values.eu-recommendation-2021-2279-pef
alloc_economic_fallbackjoint_productsWhen no defensible physical relation exists, use a documented economic relation for the same representative period and disclose prices, currency, geography, period, and sensitivity; this PCR supplies no default shares.eu-recommendation-2021-2279-pef
alloc_waste_no_creditwaste_outputsAssign no co-product credit to a waste output unless the foreground record demonstrates recovered product status and a receiving product use; preserve treatment burdens and destination records otherwise.ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
alloc_reference_consistencyreference_productNormalize only after applying one consistently documented allocation method across the reporting period, and reconcile allocated burdens to the unallocated foreground total.eu-recommendation-2021-2279-pef

8. Foreground Data Collection, Calculation, and Quality Rules

Foreground quantities come from facility measurements, logs, invoices, stock movements, laboratory reports, and reconciled calculations. Source documents define method and completeness requirements, not default quantities.

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_live_equine_receiving_recordslive_equine_receiving_and_lairageall_atomic_exchangessite_measurement_recordtimestamp;lot_id;flow_name;gross_amount;tare_amount;net_amount;meter_reading;unit;destination;evidence_refdirect_measurement_plus_record_reconciliationnative_record_unit_then_card_unitcontinuous_meter_or_per_lot_recorddeclared_reporting_period_covering_all_in_scope_operationsreporting_facilitysum_valid_records_then_normalize_to_process_outputcalibration_log;weigh_ticket;meter_log;invoice;stock_record;dispatch_record
cp_equine_slaughter_recordsequine_slaughter_bleeding_skinning_eviscerationall_atomic_exchangessite_measurement_recordtimestamp;lot_id;flow_name;gross_amount;tare_amount;net_amount;meter_reading;unit;destination;inspection_status;evidence_refdirect_measurement_plus_mass_balance_reconciliationnative_record_unit_then_card_unitcontinuous_meter_or_per_lot_recorddeclared_reporting_period_covering_all_in_scope_operationsreporting_facilitysum_valid_records_then_normalize_to_process_outputcalibration_log;weigh_ticket;meter_log;invoice;inspection_record;dispatch_record
cp_equine_cutting_recordsequine_carcass_dressing_and_cuttingall_atomic_exchangessite_measurement_recordtimestamp;lot_id;flow_name;input_mass;output_mass;meter_reading;unit;destination;inspection_status;evidence_refdirect_measurement_plus_mass_balance_reconciliationnative_record_unit_then_card_unitcontinuous_meter_or_per_lot_recorddeclared_reporting_period_covering_all_in_scope_operationsreporting_facilitysum_valid_records_then_normalize_to_process_outputcalibration_log;weigh_ticket;meter_log;invoice;inspection_record;dispatch_record
cp_prechilling_freezing_recordsprechilling_and_freezingall_atomic_exchangessite_measurement_recordtimestamp;lot_id;flow_name;input_mass;output_mass;meter_reading;refrigerant_opening_stock;refrigerant_addition;refrigerant_closing_stock;refrigerant_recovery;unit;evidence_refdirect_measurement_plus_inventory_balancenative_record_unit_then_card_unitcontinuous_meter_or_per_lot_recorddeclared_reporting_period_covering_all_in_scope_operationsreporting_facilitysum_valid_records_then_normalize_to_process_outputcalibration_log;weigh_ticket;meter_log;invoice;refrigerant_service_log;stock_record
cp_packaging_frozen_storage_release_recordspackaging_frozen_storage_and_releaseall_atomic_exchangessite_measurement_recordtimestamp;lot_id;flow_name;issued_mass;returned_mass;waste_mass;product_net_mass;meter_reading;storage_duration;refrigerant_opening_stock;refrigerant_addition;refrigerant_closing_stock;refrigerant_recovery;unit;evidence_refdirect_measurement_plus_inventory_balancenative_record_unit_then_card_unitcontinuous_meter_or_per_lot_recorddeclared_reporting_period_covering_all_in_scope_operationsreporting_facilitysum_valid_records_then_normalize_to_reference_outputcalibration_log;weigh_ticket;meter_log;invoice;packaging_issue_record;release_record;refrigerant_service_log
cp_cleaning_disinfection_recordscleaning_and_disinfectionall_atomic_exchangessite_measurement_recordtimestamp;cleaning_event;flow_name;issued_mass;solution_concentration;meter_reading;discharge_volume;unit;served_area;served_process;evidence_refdirect_measurement_plus_sanitation_allocationnative_record_unit_then_card_unitper_cleaning_event_plus_continuous_meterdeclared_reporting_period_covering_all_in_scope_operationsreporting_facilitysum_valid_records_then_allocate_with_documented_sanitation_drivermeter_log;dosing_log;stock_record;cleaning_schedule;calibration_log
cp_onsite_wastewater_treatment_recordsonsite_wastewater_treatmentall_atomic_exchangessite_measurement_recordtimestamp;flow_name;inlet_volume;outlet_volume;chemical_dose;wet_residue_mass;sample_time;concentration;unit;destination;evidence_refdirect_measurement_plus_matched_flow_concentration_calculationnative_record_unit_then_card_unitcontinuous_flow_plus_each_compliance_sampledeclared_reporting_period_covering_all_in_scope_operationsreporting_facilitytime_align_valid_records_then_normalize_to_reference_outputflow_meter_log;laboratory_report;chain_of_custody;dosing_log;residue_dispatch_record;calibration_log

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
calc_receiving_mass_balancelive equine receivingaccepted live mass = received live mass - dead carcass mass - documented reception mass adjustment; retain lot-level reconciliationreceived live mass; dead carcass mass; documented adjustmentaccepted live equine animal massec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
calc_slaughter_mass_balanceslaughter outputsreconcile accepted live mass to carcass, blood, hide, organ, digestive-content, condemned-material, wastewater-solids, and documented process-loss records without assigning a default yieldaccepted live mass; every weighed slaughter output; documented stock changeslaughter mass-balance residualec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
calc_cutting_mass_balancedressing and cutting outputsreconcile carcass input to unfrozen meat, fat, bone, trimming, condemned-meat, inedible-tissue, and stock-change records without assigning a default yieldcarcass mass; every weighed cutting output; documented stock changecutting mass-balance residualec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
calc_stage_utility_normalizationstage utilitiesstage quantity per basis = validated stage meter, invoice, or stock quantity divided by the matching process output or reference-product massvalidated stage quantity; matching denominator massnormalized atomic utility quantityeu-recommendation-2021-2279-pef
calc_refrigerant_losseach refrigerant circuitrefrigerant loss = opening stock + documented additions - closing stock - documented recovered or transferred mass; calculate separately for each named refrigerant and stageopening stock; additions; closing stock; recovered mass; transferred massnamed refrigerant emission massec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
calc_packaging_material_balanceeach packaging materialpackaging consumed = issued mass - returned unused mass - closing work-in-process stock; reusable packaging allocation uses recorded cycles with the method disclosedissued mass; returned mass; stock change; recorded reuse cyclesmaterial-specific packaging input per reference producteu-recommendation-2021-2279-pef
calc_combustion_emissioneach stage combustion emissionemission mass = stage fuel quantity multiplied by the disclosed site-measurement or factor basis; calculate each named air emission separately and do not assign a PCR default factorstage fuel quantity; disclosed measurement or factor; oxidation and unit-conversion recordssingle air-emission massec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
calc_wastewater_flow_balanceon-site wastewater treatmenttreated volume balance = sum of separately recorded inlet wastewater volumes plus treatment water - treated wastewater volume - documented water retained in sludge - documented evaporationeach inlet volume; treatment water; effluent volume; sludge water; evaporation recordwastewater-treatment volume-balance residualec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
calc_effluent_pollutant_loadeach water emissiondischarged mass = time-matched final-effluent volume multiplied by validated final-effluent concentration with unit conversion; calculate each analyte separatelyfinal-effluent volume; analyte concentration; sample time; unit conversionsingle water-emission massec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
calc_reference_product_massreference productnet reference mass = gross released packaged lot mass - all packaging-component mass; normalize the foreground inventory to exactly 1 kg net conforming frozen productgross released mass; each packaging-component mass; release status1 kg net reference productun-cpc-3-0; eu-recommendation-2021-2279-pef

Data Quality Requirements

requirement_idApplies toRequirementEvidence
dq_technologicalall foreground stagesRepresent the actual slaughter, cutting, freezing, packaging, sanitation, and wastewater technologies used during the declared reporting period.equipment list; process diagram; operating log
dq_temporalall collected recordsUse one declared reporting period that covers all in-scope operations and disclose shutdowns, atypical lots, missing intervals, and substitutions.dated meter logs; production calendar; gap register
dq_geographicalfacility and utilitiesDeclare facility location, electricity supply geography, water source, fuel supply basis, wastewater destination, and co-product destination.site metadata; invoices; permits; dispatch records
dq_completenessall atomic exchangesCollect every known material, utility, product, co-product, waste, and air, water, or soil emission; explain any verified zero and do not hide a flow through aggregation.flow register; completeness reconciliation; zero-evidence record
dq_mass_balanceanimal, carcass, meat, co-product, and waste massesMaintain lot or reporting-period mass balances with gross, tare, net, stock-change, moisture, and destination records sufficient to explain residuals.weigh tickets; stock records; balance worksheet
dq_energyelectricity, steam, hot water, natural gas, diesel, and LPGKeep each carrier separate by stage and reconcile meters, invoices, stock movements, allocation drivers, and unit conversions.meter logs; invoices; tank records; allocation worksheet
dq_refrigeranteach named refrigerantKeep make-up and emission balances separate by refrigerant and by freezing or frozen-storage stage; disclose maintenance, recovery, and data gaps.service logs; cylinder records; inventory balance
dq_wastewatereach wastewater and water emissionPreserve originating wastewater streams, treatment flow balance, matched sampling times, analytical method, detection-limit treatment, and discharge destination.flow logs; laboratory reports; chain of custody; permit record
dq_allocationreference product and recovered outputsDisclose subdivision, physical relation, economic data period when used, waste classification, destination, and sensitivity for every burden-sharing decision.allocation worksheet; sales or physical-driver evidence; sensitivity result
dq_verificationpublished foreground data packageRetain traceable source records, calculation formulas, reviewer checks, corrections, and unresolved identity records so an independent reviewer can reproduce every reported exchange.audit trail; formula workbook; review record; manifest review metadata

9. Validation Rules

rule_idApplies toRulesource_ids
val_identityreference_flowThe sole reference flow UUID shall be b1d61fc0-90f2-4ef0-959b-b62596caca1a, public state 100, version 01.01.000, Product, exact CPC 21138, Mass property 93a60a56-a3c8-11da-a746-0800200b9a66, Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66, and kg.un-cpc-3-0
val_reference_massreference_quantityThe quantitative reference shall equal exactly 1 kg net conforming frozen product, and every packaging-component mass shall be excluded from that net mass.un-cpc-3-0; eu-recommendation-2021-2279-pef
val_scope_stateproduct_scopeDataset metadata shall identify frozen equine meat and shall not present fresh or chilled meat or edible offal as the reference product.un-cpc-3-0
val_process_coverageprocess_mapAll six required processes shall contain records; on-site wastewater treatment shall be present when its inclusion condition is met and explicitly marked not applicable with evidence otherwise.ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
val_atomic_inventoryprocess_inventoryEvery inventory card shall contain one named atomic exchange; no utility, refrigerant, chemical, packaging, waste, or emission selector may replace a flow identity.ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
val_uuid_integrityinventory_flow_identityOnly the verified reference UUID may be populated from the supplied evidence; every non-reference UUID remains blank until hybrid discovery and public state-100 direct read independently confirm exact semantics, type, property, unit group, and unit, with unresolved row metadata updated together.eu-recommendation-2021-2279-pef
val_value_modeinventory_amountsThe reference output alone uses fixed_value; measured records use foreground_record, derived balances use calculated_value, and no author-estimated range or default amount is permitted.eu-recommendation-2021-2279-pef
val_card_completenessprocess_inventoryEvery card shall have a non-empty description, selected flow, property and unit, amount rule, controlled value mode, specificity, basis, basis kind, evidence kind, collection protocol, and source ids.eu-recommendation-2021-2279-pef
val_mass_balanceforeground_mass_flowsReception, slaughter, cutting, freezing, packaging, and wastewater volume or mass balances shall be reconciled and residuals explained without inserting a default yield.ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
val_stage_energyenergy_inventoryElectricity, purchased steam, purchased hot water, natural gas, diesel, and LPG shall remain separate by stage, with shared-meter allocation drivers documented.ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
val_refrigerantsrefrigeration_inventoryMake-up and air emission shall be separately balanced for each named refrigerant at freezing and frozen storage; any additional site-used refrigerant requires its own atomic input and emission records before release.ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
val_wastewaterwastewater_inventoryEach originating wastewater stream, treated wastewater, sludge, screenings, and each water emission shall be separately reconciled to flow and analytical records with destination disclosed.ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
val_allocationallocationEvery joint-output burden decision shall follow the declared hierarchy, disclose data and period, preserve waste status evidence, and reconcile allocated totals.eu-recommendation-2021-2279-pef
val_sourcesevidenceMethod claims shall cite only the three declared sources; foreground quantities shall trace to facility records rather than a source-derived default.un-cpc-3-0; ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef
val_bilingual_alignmentlocalized_markdownEnglish and Chinese files shall preserve identical ordered process_id, row_id, direction, flow_type, UUID, controlled amount fields, collection protocol, and source-id sequences.eu-recommendation-2021-2279-pef

10. Published Dataset Profile

FieldValue
dataset_roleSite-specific foreground data package for 1 kg net conforming frozen meat of horses or other equines at frozen-store release
downstream_useInput to reviewed process datasets and lifecycle models that require a CPC 21138 foreground manufacturing inventory
allowed_useFacility-specific gate-to-gate modelling; cradle-to-gate modelling when transparent upstream datasets are linked; comparative use only after equivalent scope, quality, allocation, and product qualifiers are confirmed
excluded_useRepresentation of fresh or chilled equine meat, edible offal, non-equine meat, retail, cooking, consumption, or undisclosed generic industry averages
required_metadatacanonical PCR id; CPC code; reference UUID; species; carcass or cut form; bone state; frozen state; facility; geography; reporting period; technology; storage duration; storage condition; packaging; process inclusion; allocation; destinations
required_quality_disclosurePrimary-data coverage; meter allocation; mass-balance residuals; refrigerant balances; wastewater sampling; analytical methods; source records; zero evidence; data gaps; substitutions; allocation sensitivity; reviewer findings
update_triggerMaterial change in product scope, facility technology, freezing system, refrigerant, packaging, storage condition, wastewater treatment, co-product destination, allocation relation, reporting period, or verified Tiangong identity

11. Data Sources

Source idTypeReferenceUsed for
un-cpc-3-0official_guidanceUnited Nations Statistics Division. Central Product Classification Version 3.0 Structure and Explanatory Notes, subclass 21138, 30 June 2025. Retained raw: classifications/systems/cpc/3.0/raw/CPC_Ver_3.0_Structure_30Jun2025.csv. https://unstats.un.org/unsd/classifications/Econ/Download/In%20Text/CPC_Ver_3.0_Exp_Notes_30Jun2025.pdfExact frozen-equine-meat classification boundary and exclusion of fresh or chilled meat and edible offal
ec-jrc-sa-bref-2024official_guidanceEuropean Commission, Joint Research Centre. Best Available Techniques Reference Document for the Slaughterhouses, Animal By-products and/or Edible Co-products Industries. JRC135916, 2024. DOI: 10.2760/18199. https://publications.jrc.ec.europa.eu/repository/handle/JRC135916Reception, slaughter, dressing, cutting, chilling, freezing, sanitation, utilities, wastewater, co-product, waste, and emission process structure; no default quantity adopted
eu-recommendation-2021-2279-pefofficial_guidanceEuropean Commission. Recommendation (EU) 2021/2279 on the use of the Environmental Footprint methods, consolidated text. https://eur-lex.europa.eu/eli/reco/2021/2279/2021-12-30/engProduct-specific bill of materials, company-specific foreground data, complete life-cycle inventory, allocation hierarchy, data quality, transparency, and verification

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page

Process: Cleaning and disinfection (cleaning_and_disinfection)InputsProduct flowsCleaning and disinfection process water (cip_process_water)Cleaning and disinfection grid electricity (cip_electricity)Cleaning and disinfection purchased steam (cip_purchased_steam)Cleaning and disinfection purchased hot water (cip_purchased_hot_water)Cleaning and disinfection natural gas (cip_natural_gas)Cleaning and disinfection diesel fuel (cip_diesel)Cleaning and disinfection liquefied petroleum gas (cip_lpg)Sodium hydroxide cleaning solution (cip_sodium_hydroxide)Nitric acid cleaning solution (cip_nitric_acid)Sodium hypochlorite disinfectant (cip_sodium_hypochlorite)Peracetic acid disinfectant (cip_peracetic_acid)Waste flowsElementary flowsOutputsProduct flowsWaste flowsSanitation wastewater (cip_sanitation_wastewater)Elementary flowsCleaning and disinfection fossil carbon dioxide emission (cip_carbon_dioxide_to_air)Cleaning and disinfection nitrogen oxides emission (cip_nitrogen_oxides_to_air)Cleaning and disinfection sulfur dioxide emission (cip_sulfur_dioxide_to_air)Cleaning and disinfection fine particulate emission (cip_particulate_matter_to_air)Process: On-site wastewater treatment (onsite_wastewater_treatment)InputsProduct flowsOn-site wastewater treatment process water (wwt_process_water)On-site wastewater treatment grid electricity (wwt_electricity)On-site wastewater treatment purchased steam (wwt_purchased_steam)On-site wastewater treatment purchased hot water (wwt_purchased_hot_water)On-site wastewater treatment natural gas (wwt_natural_gas)On-site wastewater treatment diesel fuel (wwt_diesel)On-site wastewater treatment liquefied petroleum gas (wwt_lpg)Ferric chloride treatment solution (wwt_ferric_chloride)Polyacrylamide flocculant (wwt_polyacrylamide)Waste flowsLairage wash wastewater entering treatment (wwt_lairage_wash_wastewater)High-organic-load slaughter wastewater entering treatment (wwt_high_organic_load_wastewater)Cutting-floor wash wastewater entering treatment (wwt_cutting_floor_wastewater)Freezer defrost wastewater entering treatment (wwt_freezer_defrost_wastewater)Packaging-area wash wastewater entering treatment (wwt_packaging_area_wastewater)Frozen-store defrost wastewater entering treatment (wwt_frozen_store_defrost_wastewater)Sanitation wastewater entering treatment (wwt_sanitation_wastewater)Elementary flowsOutputsProduct flowsWaste flowsTreated slaughterhouse wastewater (wwt_treated_wastewater)Slaughterhouse wastewater-treatment sludge (wwt_sludge)Slaughterhouse wastewater screenings (wwt_screenings)Elementary flowsChemical oxygen demand discharge (wwt_cod_to_water)Total nitrogen discharge (wwt_total_nitrogen_to_water)Total phosphorus discharge (wwt_total_phosphorus_to_water)Total suspended solids discharge (wwt_total_suspended_solids_to_water)On-site wastewater treatment fossil carbon dioxide emission (wwt_carbon_dioxide_to_air)On-site wastewater treatment nitrogen oxides emission (wwt_nitrogen_oxides_to_air)On-site wastewater treatment sulfur dioxide emission (wwt_sulfur_dioxide_to_air)On-site wastewater treatment fine particulate emission (wwt_particulate_matter_to_air)7. Allocation and Co-product Handling8. Foreground Data Collection, Calculation, and Quality RulesData Collection ProtocolsCalculation RulesData Quality Requirements9. Validation Rules10. Published Dataset Profile11. Data Sources