Meat of horses and other equines, frozen · Process: Cleaning and disinfection (cleaning_and_disinfection)
Meat of horses and other equines, frozen · Process: Cleaning and disinfection (cleaning_and_disinfection): Process water crosses the cleaning and disinfection boundary…
- Lifecycle status
- Candidate
- Content maturity
- Authored methodology
- Current version
- No published version
- Readiness
- Review required
- Last updated
Methodology and translation states come from the source record; publishing this website does not change their review status.
Content languages
Status, classification and source details
Readiness
- Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.
Classification mapping
Source
Process: Cleaning and disinfection (cleaning_and_disinfection)
Inputs
Product flows
Cleaning and disinfection process water (cip_process_water)
Process water crosses the cleaning and disinfection boundary for equipment operation, washing, or hygiene duties assigned to this stage.
- Selected flow: Process water
- Flow property / unit: Volume / m3
- Amount rule: Record the metered or reconciled volume consumed by this stage during the reporting period.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_cleaning_disinfection_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Cleaning and disinfection grid electricity (cip_electricity)
Grid electricity crosses the cleaning and disinfection boundary to operate equipment assigned to this stage.
- Selected flow: Electricity, grid
- Flow property / unit: Energy / kWh
- Amount rule: Record the stage meter reading; when only a shared meter exists, allocate the measured total with a documented operating driver.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_cleaning_disinfection_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Cleaning and disinfection purchased steam (cip_purchased_steam)
Purchased steam crosses the cleaning and disinfection boundary when the facility supplies steam to this stage.
- Selected flow: Purchased steam
- Flow property / unit: Mass / kg
- Amount rule: Record the metered or supplier-reconciled steam mass attributable to this stage; report zero only with evidence of absence.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_cleaning_disinfection_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Cleaning and disinfection purchased hot water (cip_purchased_hot_water)
Purchased hot water crosses the cleaning and disinfection boundary when hot water is supplied as a separately delivered utility.
- Selected flow: Purchased hot water
- Flow property / unit: Mass / kg
- Amount rule: Record the delivered hot-water mass attributable to this stage from meters, delivery records, or a documented balance.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_cleaning_disinfection_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Cleaning and disinfection natural gas (cip_natural_gas)
Natural gas crosses the cleaning and disinfection boundary when directly combusted by equipment assigned to this stage.
- Selected flow: Natural gas
- Flow property / unit: Energy / MJ
- Amount rule: Record fuel consumption and convert to energy using the declared metering and calorific-value basis.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_cleaning_disinfection_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Cleaning and disinfection diesel fuel (cip_diesel)
Diesel fuel crosses the cleaning and disinfection boundary when stationary or mobile equipment assigned to this stage consumes diesel on site.
- Selected flow: Diesel fuel
- Flow property / unit: Mass / kg
- Amount rule: Record issued or metered diesel mass assigned to this stage and reconcile it to stock records.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_cleaning_disinfection_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Cleaning and disinfection liquefied petroleum gas (cip_lpg)
Liquefied petroleum gas crosses the cleaning and disinfection boundary when equipment assigned to this stage consumes it on site.
- Selected flow: Liquefied petroleum gas
- Flow property / unit: Mass / kg
- Amount rule: Record delivered or issued LPG mass assigned to this stage and reconcile it to stock records.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_cleaning_disinfection_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Sodium hydroxide cleaning solution (cip_sodium_hydroxide)
Sodium hydroxide cleaning solution crosses the sanitation boundary only when a site record confirms its use.
- Selected flow: Sodium hydroxide cleaning solution
- Flow property / unit: Mass / kg solution
- Amount rule: Record issued solution mass and concentration from stock, dosing, and batch records; report zero only with evidence of absence.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_cleaning_disinfection_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Nitric acid cleaning solution (cip_nitric_acid)
Nitric acid cleaning solution crosses the sanitation boundary only when a site record confirms its use.
- Selected flow: Nitric acid cleaning solution
- Flow property / unit: Mass / kg solution
- Amount rule: Record issued solution mass and concentration from stock, dosing, and batch records; report zero only with evidence of absence.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_cleaning_disinfection_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Sodium hypochlorite disinfectant (cip_sodium_hypochlorite)
Sodium hypochlorite disinfectant crosses the sanitation boundary only when a site record confirms its use.
- Selected flow: Sodium hypochlorite disinfectant
- Flow property / unit: Mass / kg solution
- Amount rule: Record issued solution mass and concentration from stock, dosing, and batch records; report zero only with evidence of absence.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_cleaning_disinfection_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Peracetic acid disinfectant (cip_peracetic_acid)
Peracetic acid disinfectant crosses the sanitation boundary only when a site record confirms its use.
- Selected flow: Peracetic acid disinfectant
- Flow property / unit: Mass / kg solution
- Amount rule: Record issued solution mass and concentration from stock, dosing, and batch records; report zero only with evidence of absence.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_cleaning_disinfection_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Waste flows
Elementary flows
Outputs
Product flows
Waste flows
Sanitation wastewater (cip_sanitation_wastewater)
Sanitation wastewater leaves cleaning and disinfection as one separately quantified liquid waste stream before treatment.
- Selected flow: Sanitation wastewater
- Flow property / unit: Volume / m3
- Amount rule: Record metered discharge volume or calculate it from the documented sanitation water balance.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_cleaning_disinfection_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Elementary flows
Cleaning and disinfection fossil carbon dioxide emission (cip_carbon_dioxide_to_air)
Fossil carbon dioxide emission crosses from cleaning and disinfection equipment to air as one separately reported elementary exchange.
- Selected flow: Carbon dioxide, fossil, to air
- Flow property / unit: Mass / kg
- Amount rule: Calculate from collected stage fuel records and the dataset's disclosed measurement or emission-factor basis; assign no PCR default.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_cleaning_disinfection_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Cleaning and disinfection nitrogen oxides emission (cip_nitrogen_oxides_to_air)
Nitrogen oxides emission crosses from cleaning and disinfection equipment to air as one separately reported elementary exchange.
- Selected flow: Nitrogen oxides to air
- Flow property / unit: Mass / kg NO2-equivalent
- Amount rule: Calculate from collected stage fuel records and the dataset's disclosed measurement or emission-factor basis; assign no PCR default.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_cleaning_disinfection_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Cleaning and disinfection sulfur dioxide emission (cip_sulfur_dioxide_to_air)
Sulfur dioxide emission crosses from cleaning and disinfection equipment to air as one separately reported elementary exchange.
- Selected flow: Sulfur dioxide to air
- Flow property / unit: Mass / kg
- Amount rule: Calculate from collected stage fuel records and the dataset's disclosed measurement or emission-factor basis; assign no PCR default.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_cleaning_disinfection_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Cleaning and disinfection fine particulate emission (cip_particulate_matter_to_air)
Fine particulate emission crosses from cleaning and disinfection equipment to air as one separately reported elementary exchange.
- Selected flow: Particulate matter, <2.5 um, to air
- Flow property / unit: Mass / kg
- Amount rule: Calculate from collected stage fuel records and the dataset's disclosed measurement or emission-factor basis; assign no PCR default.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using a documented sanitation allocation driver
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_cleaning_disinfection_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Process: On-site wastewater treatment (onsite_wastewater_treatment)
Inputs
Product flows
On-site wastewater treatment process water (wwt_process_water)
Process water crosses the on-site wastewater treatment boundary for equipment operation, washing, or hygiene duties assigned to this stage.
- Selected flow: Process water
- Flow property / unit: Volume / m3
- Amount rule: Record the metered or reconciled volume consumed by this stage during the reporting period.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
On-site wastewater treatment grid electricity (wwt_electricity)
Grid electricity crosses the on-site wastewater treatment boundary to operate equipment assigned to this stage.
- Selected flow: Electricity, grid
- Flow property / unit: Energy / kWh
- Amount rule: Record the stage meter reading; when only a shared meter exists, allocate the measured total with a documented operating driver.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
On-site wastewater treatment purchased steam (wwt_purchased_steam)
Purchased steam crosses the on-site wastewater treatment boundary when the facility supplies steam to this stage.
- Selected flow: Purchased steam
- Flow property / unit: Mass / kg
- Amount rule: Record the metered or supplier-reconciled steam mass attributable to this stage; report zero only with evidence of absence.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
On-site wastewater treatment purchased hot water (wwt_purchased_hot_water)
Purchased hot water crosses the on-site wastewater treatment boundary when hot water is supplied as a separately delivered utility.
- Selected flow: Purchased hot water
- Flow property / unit: Mass / kg
- Amount rule: Record the delivered hot-water mass attributable to this stage from meters, delivery records, or a documented balance.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
On-site wastewater treatment natural gas (wwt_natural_gas)
Natural gas crosses the on-site wastewater treatment boundary when directly combusted by equipment assigned to this stage.
- Selected flow: Natural gas
- Flow property / unit: Energy / MJ
- Amount rule: Record fuel consumption and convert to energy using the declared metering and calorific-value basis.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
On-site wastewater treatment diesel fuel (wwt_diesel)
Diesel fuel crosses the on-site wastewater treatment boundary when stationary or mobile equipment assigned to this stage consumes diesel on site.
- Selected flow: Diesel fuel
- Flow property / unit: Mass / kg
- Amount rule: Record issued or metered diesel mass assigned to this stage and reconcile it to stock records.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
On-site wastewater treatment liquefied petroleum gas (wwt_lpg)
Liquefied petroleum gas crosses the on-site wastewater treatment boundary when equipment assigned to this stage consumes it on site.
- Selected flow: Liquefied petroleum gas
- Flow property / unit: Mass / kg
- Amount rule: Record delivered or issued LPG mass assigned to this stage and reconcile it to stock records.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Ferric chloride treatment solution (wwt_ferric_chloride)
Ferric chloride solution crosses the wastewater-treatment boundary only when a dosing record confirms its use.
- Selected flow: Ferric chloride solution
- Flow property / unit: Mass / kg solution
- Amount rule: Record dosed solution mass and concentration from treatment logs; report zero only with evidence of absence.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Polyacrylamide flocculant (wwt_polyacrylamide)
Polyacrylamide flocculant crosses the wastewater-treatment boundary only when a dosing record confirms its use.
- Selected flow: Polyacrylamide flocculant
- Flow property / unit: Mass / kg solution
- Amount rule: Record dosed solution mass and concentration from treatment logs; report zero only with evidence of absence.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Waste flows
Lairage wash wastewater entering treatment (wwt_lairage_wash_wastewater)
Lairage wash wastewater enters on-site treatment as one separately reconciled waste input from its originating foreground stage.
- Selected flow: Lairage wash wastewater
- Flow property / unit: Volume / m3
- Amount rule: Use the originating stage volume and reconcile it to the treatment inlet flow balance.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
High-organic-load slaughter wastewater entering treatment (wwt_high_organic_load_wastewater)
High-organic-load slaughter wastewater enters on-site treatment as one separately reconciled waste input from its originating foreground stage.
- Selected flow: High-organic-load slaughter wastewater
- Flow property / unit: Volume / m3
- Amount rule: Use the originating stage volume and reconcile it to the treatment inlet flow balance.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Cutting-floor wash wastewater entering treatment (wwt_cutting_floor_wastewater)
Cutting-floor wash wastewater enters on-site treatment as one separately reconciled waste input from its originating foreground stage.
- Selected flow: Cutting-floor wash wastewater
- Flow property / unit: Volume / m3
- Amount rule: Use the originating stage volume and reconcile it to the treatment inlet flow balance.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Freezer defrost wastewater entering treatment (wwt_freezer_defrost_wastewater)
Freezer defrost wastewater enters on-site treatment as one separately reconciled waste input from its originating foreground stage.
- Selected flow: Freezer defrost wastewater
- Flow property / unit: Volume / m3
- Amount rule: Use the originating stage volume and reconcile it to the treatment inlet flow balance.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Packaging-area wash wastewater entering treatment (wwt_packaging_area_wastewater)
Packaging-area wash wastewater enters on-site treatment as one separately reconciled waste input from its originating foreground stage.
- Selected flow: Packaging-area wash wastewater
- Flow property / unit: Volume / m3
- Amount rule: Use the originating stage volume and reconcile it to the treatment inlet flow balance.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Frozen-store defrost wastewater entering treatment (wwt_frozen_store_defrost_wastewater)
Frozen-store defrost wastewater enters on-site treatment as one separately reconciled waste input from its originating foreground stage.
- Selected flow: Frozen-store defrost wastewater
- Flow property / unit: Volume / m3
- Amount rule: Use the originating stage volume and reconcile it to the treatment inlet flow balance.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Sanitation wastewater entering treatment (wwt_sanitation_wastewater)
Sanitation wastewater enters on-site treatment as one separately reconciled waste input from its originating foreground stage.
- Selected flow: Sanitation wastewater
- Flow property / unit: Volume / m3
- Amount rule: Use the originating stage volume and reconcile it to the treatment inlet flow balance.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Elementary flows
Outputs
Product flows
Waste flows
Treated slaughterhouse wastewater (wwt_treated_wastewater)
Treated slaughterhouse wastewater leaves on-site treatment as one quantified water-carrier waste flow before discharge or further transfer.
- Selected flow: Treated slaughterhouse wastewater
- Flow property / unit: Volume / m3
- Amount rule: Record final effluent flow-meter volume and discharge or transfer destination.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Slaughterhouse wastewater-treatment sludge (wwt_sludge)
Wastewater-treatment sludge leaves the treatment process as one separately weighed wet waste stream.
- Selected flow: Slaughterhouse wastewater-treatment sludge
- Flow property / unit: Mass / kg wet matter
- Amount rule: Record dewatered wet mass and treatment destination from operating records.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Slaughterhouse wastewater screenings (wwt_screenings)
Screenings removed from slaughterhouse wastewater leave treatment as one separately weighed wet waste stream.
- Selected flow: Slaughterhouse wastewater screenings
- Flow property / unit: Mass / kg wet matter
- Amount rule: Record dewatered wet mass and treatment destination from operating records.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Elementary flows
Chemical oxygen demand discharge (wwt_cod_to_water)
Chemical oxygen demand discharge crosses from the on-site treatment outlet to the receiving water compartment as one separately reported elementary exchange.
- Selected flow: Chemical oxygen demand to water
- Flow property / unit: Mass / kg O2-equivalent
- Amount rule: Calculate discharged COD mass from matched effluent volume and laboratory concentration records after blank, unit, and time alignment checks.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Total nitrogen discharge (wwt_total_nitrogen_to_water)
Total nitrogen discharge crosses from the on-site treatment outlet to the receiving water compartment as one separately reported elementary exchange.
- Selected flow: Total nitrogen to water
- Flow property / unit: Mass / kg N
- Amount rule: Calculate discharged total nitrogen mass from matched effluent volume and laboratory concentration records after blank, unit, and time alignment checks.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Total phosphorus discharge (wwt_total_phosphorus_to_water)
Total phosphorus discharge crosses from the on-site treatment outlet to the receiving water compartment as one separately reported elementary exchange.
- Selected flow: Total phosphorus to water
- Flow property / unit: Mass / kg P
- Amount rule: Calculate discharged total phosphorus mass from matched effluent volume and laboratory concentration records after blank, unit, and time alignment checks.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
Total suspended solids discharge (wwt_total_suspended_solids_to_water)
Total suspended solids discharge crosses from the on-site treatment outlet to the receiving water compartment as one separately reported elementary exchange.
- Selected flow: Total suspended solids to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate discharged total suspended solids mass from matched effluent volume and laboratory concentration records after blank, unit, and time alignment checks.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
On-site wastewater treatment fossil carbon dioxide emission (wwt_carbon_dioxide_to_air)
Fossil carbon dioxide emission crosses from on-site wastewater treatment equipment to air as one separately reported elementary exchange.
- Selected flow: Carbon dioxide, fossil, to air
- Flow property / unit: Mass / kg
- Amount rule: Calculate from collected stage fuel records and the dataset's disclosed measurement or emission-factor basis; assign no PCR default.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
On-site wastewater treatment nitrogen oxides emission (wwt_nitrogen_oxides_to_air)
Nitrogen oxides emission crosses from on-site wastewater treatment equipment to air as one separately reported elementary exchange.
- Selected flow: Nitrogen oxides to air
- Flow property / unit: Mass / kg NO2-equivalent
- Amount rule: Calculate from collected stage fuel records and the dataset's disclosed measurement or emission-factor basis; assign no PCR default.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
On-site wastewater treatment sulfur dioxide emission (wwt_sulfur_dioxide_to_air)
Sulfur dioxide emission crosses from on-site wastewater treatment equipment to air as one separately reported elementary exchange.
- Selected flow: Sulfur dioxide to air
- Flow property / unit: Mass / kg
- Amount rule: Calculate from collected stage fuel records and the dataset's disclosed measurement or emission-factor basis; assign no PCR default.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
On-site wastewater treatment fine particulate emission (wwt_particulate_matter_to_air)
Fine particulate emission crosses from on-site wastewater treatment equipment to air as one separately reported elementary exchange.
- Selected flow: Particulate matter, <2.5 um, to air
- Flow property / unit: Mass / kg
- Amount rule: Calculate from collected stage fuel records and the dataset's disclosed measurement or emission-factor basis; assign no PCR default.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net reference product using measured treated volume
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_onsite_wastewater_treatment_records - Sources:
ec-jrc-sa-bref-2024;eu-recommendation-2021-2279-pef
7. Allocation and Co-product Handling
| rule_id | Applies to | Rule | source_ids |
|---|---|---|---|
alloc_subdivision_first | separable_processes | Avoid allocation first by subdividing metered operations and directly assigning stage utilities, packaging, chemicals, wastes, and emissions to the process output that causes them. | eu-recommendation-2021-2279-pef |
alloc_product_waste_status | all_non_reference_outputs | Classify every blood, hide, organ, fat, bone, trimming, condemned-material, digestive-content, sludge, screening, and packaging output as a product, co-product, or waste from documented legal, technical, and destination evidence; do not infer saleable status. | ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef |
alloc_physical_relation | joint_products | When subdivision cannot avoid burden sharing and a causal physical relation can be demonstrated, allocate the residual burden with that documented physical relation and report the driver values. | eu-recommendation-2021-2279-pef |
alloc_economic_fallback | joint_products | When no defensible physical relation exists, use a documented economic relation for the same representative period and disclose prices, currency, geography, period, and sensitivity; this PCR supplies no default shares. | eu-recommendation-2021-2279-pef |
alloc_waste_no_credit | waste_outputs | Assign no co-product credit to a waste output unless the foreground record demonstrates recovered product status and a receiving product use; preserve treatment burdens and destination records otherwise. | ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef |
alloc_reference_consistency | reference_product | Normalize only after applying one consistently documented allocation method across the reporting period, and reconcile allocated burdens to the unallocated foreground total. | eu-recommendation-2021-2279-pef |
8. Foreground Data Collection, Calculation, and Quality Rules
Foreground quantities come from facility measurements, logs, invoices, stock movements, laboratory reports, and reconciled calculations. Source documents define method and completeness requirements, not default quantities.
Data Collection Protocols
| protocol_id | process_id | flow_role | record_type | raw_fields | collection_method | unit | frequency | temporal_coverage | site_scope | aggregation_rule | quality_evidence |
|---|---|---|---|---|---|---|---|---|---|---|---|
cp_live_equine_receiving_records | live_equine_receiving_and_lairage | all_atomic_exchanges | site_measurement_record | timestamp;lot_id;flow_name;gross_amount;tare_amount;net_amount;meter_reading;unit;destination;evidence_ref | direct_measurement_plus_record_reconciliation | native_record_unit_then_card_unit | continuous_meter_or_per_lot_record | declared_reporting_period_covering_all_in_scope_operations | reporting_facility | sum_valid_records_then_normalize_to_process_output | calibration_log;weigh_ticket;meter_log;invoice;stock_record;dispatch_record |
cp_equine_slaughter_records | equine_slaughter_bleeding_skinning_evisceration | all_atomic_exchanges | site_measurement_record | timestamp;lot_id;flow_name;gross_amount;tare_amount;net_amount;meter_reading;unit;destination;inspection_status;evidence_ref | direct_measurement_plus_mass_balance_reconciliation | native_record_unit_then_card_unit | continuous_meter_or_per_lot_record | declared_reporting_period_covering_all_in_scope_operations | reporting_facility | sum_valid_records_then_normalize_to_process_output | calibration_log;weigh_ticket;meter_log;invoice;inspection_record;dispatch_record |
cp_equine_cutting_records | equine_carcass_dressing_and_cutting | all_atomic_exchanges | site_measurement_record | timestamp;lot_id;flow_name;input_mass;output_mass;meter_reading;unit;destination;inspection_status;evidence_ref | direct_measurement_plus_mass_balance_reconciliation | native_record_unit_then_card_unit | continuous_meter_or_per_lot_record | declared_reporting_period_covering_all_in_scope_operations | reporting_facility | sum_valid_records_then_normalize_to_process_output | calibration_log;weigh_ticket;meter_log;invoice;inspection_record;dispatch_record |
cp_prechilling_freezing_records | prechilling_and_freezing | all_atomic_exchanges | site_measurement_record | timestamp;lot_id;flow_name;input_mass;output_mass;meter_reading;refrigerant_opening_stock;refrigerant_addition;refrigerant_closing_stock;refrigerant_recovery;unit;evidence_ref | direct_measurement_plus_inventory_balance | native_record_unit_then_card_unit | continuous_meter_or_per_lot_record | declared_reporting_period_covering_all_in_scope_operations | reporting_facility | sum_valid_records_then_normalize_to_process_output | calibration_log;weigh_ticket;meter_log;invoice;refrigerant_service_log;stock_record |
cp_packaging_frozen_storage_release_records | packaging_frozen_storage_and_release | all_atomic_exchanges | site_measurement_record | timestamp;lot_id;flow_name;issued_mass;returned_mass;waste_mass;product_net_mass;meter_reading;storage_duration;refrigerant_opening_stock;refrigerant_addition;refrigerant_closing_stock;refrigerant_recovery;unit;evidence_ref | direct_measurement_plus_inventory_balance | native_record_unit_then_card_unit | continuous_meter_or_per_lot_record | declared_reporting_period_covering_all_in_scope_operations | reporting_facility | sum_valid_records_then_normalize_to_reference_output | calibration_log;weigh_ticket;meter_log;invoice;packaging_issue_record;release_record;refrigerant_service_log |
cp_cleaning_disinfection_records | cleaning_and_disinfection | all_atomic_exchanges | site_measurement_record | timestamp;cleaning_event;flow_name;issued_mass;solution_concentration;meter_reading;discharge_volume;unit;served_area;served_process;evidence_ref | direct_measurement_plus_sanitation_allocation | native_record_unit_then_card_unit | per_cleaning_event_plus_continuous_meter | declared_reporting_period_covering_all_in_scope_operations | reporting_facility | sum_valid_records_then_allocate_with_documented_sanitation_driver | meter_log;dosing_log;stock_record;cleaning_schedule;calibration_log |
cp_onsite_wastewater_treatment_records | onsite_wastewater_treatment | all_atomic_exchanges | site_measurement_record | timestamp;flow_name;inlet_volume;outlet_volume;chemical_dose;wet_residue_mass;sample_time;concentration;unit;destination;evidence_ref | direct_measurement_plus_matched_flow_concentration_calculation | native_record_unit_then_card_unit | continuous_flow_plus_each_compliance_sample | declared_reporting_period_covering_all_in_scope_operations | reporting_facility | time_align_valid_records_then_normalize_to_reference_output | flow_meter_log;laboratory_report;chain_of_custody;dosing_log;residue_dispatch_record;calibration_log |
Calculation Rules
| rule_id | Applies to | Formula or rule | Inputs | Output | source_ids |
|---|---|---|---|---|---|
calc_receiving_mass_balance | live equine receiving | accepted live mass = received live mass - dead carcass mass - documented reception mass adjustment; retain lot-level reconciliation | received live mass; dead carcass mass; documented adjustment | accepted live equine animal mass | ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef |
calc_slaughter_mass_balance | slaughter outputs | reconcile accepted live mass to carcass, blood, hide, organ, digestive-content, condemned-material, wastewater-solids, and documented process-loss records without assigning a default yield | accepted live mass; every weighed slaughter output; documented stock change | slaughter mass-balance residual | ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef |
calc_cutting_mass_balance | dressing and cutting outputs | reconcile carcass input to unfrozen meat, fat, bone, trimming, condemned-meat, inedible-tissue, and stock-change records without assigning a default yield | carcass mass; every weighed cutting output; documented stock change | cutting mass-balance residual | ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef |
calc_stage_utility_normalization | stage utilities | stage quantity per basis = validated stage meter, invoice, or stock quantity divided by the matching process output or reference-product mass | validated stage quantity; matching denominator mass | normalized atomic utility quantity | eu-recommendation-2021-2279-pef |
calc_refrigerant_loss | each refrigerant circuit | refrigerant loss = opening stock + documented additions - closing stock - documented recovered or transferred mass; calculate separately for each named refrigerant and stage | opening stock; additions; closing stock; recovered mass; transferred mass | named refrigerant emission mass | ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef |
calc_packaging_material_balance | each packaging material | packaging consumed = issued mass - returned unused mass - closing work-in-process stock; reusable packaging allocation uses recorded cycles with the method disclosed | issued mass; returned mass; stock change; recorded reuse cycles | material-specific packaging input per reference product | eu-recommendation-2021-2279-pef |
calc_combustion_emission | each stage combustion emission | emission mass = stage fuel quantity multiplied by the disclosed site-measurement or factor basis; calculate each named air emission separately and do not assign a PCR default factor | stage fuel quantity; disclosed measurement or factor; oxidation and unit-conversion records | single air-emission mass | ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef |
calc_wastewater_flow_balance | on-site wastewater treatment | treated volume balance = sum of separately recorded inlet wastewater volumes plus treatment water - treated wastewater volume - documented water retained in sludge - documented evaporation | each inlet volume; treatment water; effluent volume; sludge water; evaporation record | wastewater-treatment volume-balance residual | ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef |
calc_effluent_pollutant_load | each water emission | discharged mass = time-matched final-effluent volume multiplied by validated final-effluent concentration with unit conversion; calculate each analyte separately | final-effluent volume; analyte concentration; sample time; unit conversion | single water-emission mass | ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef |
calc_reference_product_mass | reference product | net reference mass = gross released packaged lot mass - all packaging-component mass; normalize the foreground inventory to exactly 1 kg net conforming frozen product | gross released mass; each packaging-component mass; release status | 1 kg net reference product | un-cpc-3-0; eu-recommendation-2021-2279-pef |
Data Quality Requirements
| requirement_id | Applies to | Requirement | Evidence |
|---|---|---|---|
dq_technological | all foreground stages | Represent the actual slaughter, cutting, freezing, packaging, sanitation, and wastewater technologies used during the declared reporting period. | equipment list; process diagram; operating log |
dq_temporal | all collected records | Use one declared reporting period that covers all in-scope operations and disclose shutdowns, atypical lots, missing intervals, and substitutions. | dated meter logs; production calendar; gap register |
dq_geographical | facility and utilities | Declare facility location, electricity supply geography, water source, fuel supply basis, wastewater destination, and co-product destination. | site metadata; invoices; permits; dispatch records |
dq_completeness | all atomic exchanges | Collect every known material, utility, product, co-product, waste, and air, water, or soil emission; explain any verified zero and do not hide a flow through aggregation. | flow register; completeness reconciliation; zero-evidence record |
dq_mass_balance | animal, carcass, meat, co-product, and waste masses | Maintain lot or reporting-period mass balances with gross, tare, net, stock-change, moisture, and destination records sufficient to explain residuals. | weigh tickets; stock records; balance worksheet |
dq_energy | electricity, steam, hot water, natural gas, diesel, and LPG | Keep each carrier separate by stage and reconcile meters, invoices, stock movements, allocation drivers, and unit conversions. | meter logs; invoices; tank records; allocation worksheet |
dq_refrigerant | each named refrigerant | Keep make-up and emission balances separate by refrigerant and by freezing or frozen-storage stage; disclose maintenance, recovery, and data gaps. | service logs; cylinder records; inventory balance |
dq_wastewater | each wastewater and water emission | Preserve originating wastewater streams, treatment flow balance, matched sampling times, analytical method, detection-limit treatment, and discharge destination. | flow logs; laboratory reports; chain of custody; permit record |
dq_allocation | reference product and recovered outputs | Disclose subdivision, physical relation, economic data period when used, waste classification, destination, and sensitivity for every burden-sharing decision. | allocation worksheet; sales or physical-driver evidence; sensitivity result |
dq_verification | published foreground data package | Retain traceable source records, calculation formulas, reviewer checks, corrections, and unresolved identity records so an independent reviewer can reproduce every reported exchange. | audit trail; formula workbook; review record; manifest review metadata |
9. Validation Rules
| rule_id | Applies to | Rule | source_ids |
|---|---|---|---|
val_identity | reference_flow | The sole reference flow UUID shall be b1d61fc0-90f2-4ef0-959b-b62596caca1a, public state 100, version 01.01.000, Product, exact CPC 21138, Mass property 93a60a56-a3c8-11da-a746-0800200b9a66, Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66, and kg. | un-cpc-3-0 |
val_reference_mass | reference_quantity | The quantitative reference shall equal exactly 1 kg net conforming frozen product, and every packaging-component mass shall be excluded from that net mass. | un-cpc-3-0; eu-recommendation-2021-2279-pef |
val_scope_state | product_scope | Dataset metadata shall identify frozen equine meat and shall not present fresh or chilled meat or edible offal as the reference product. | un-cpc-3-0 |
val_process_coverage | process_map | All six required processes shall contain records; on-site wastewater treatment shall be present when its inclusion condition is met and explicitly marked not applicable with evidence otherwise. | ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef |
val_atomic_inventory | process_inventory | Every inventory card shall contain one named atomic exchange; no utility, refrigerant, chemical, packaging, waste, or emission selector may replace a flow identity. | ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef |
val_uuid_integrity | inventory_flow_identity | Only the verified reference UUID may be populated from the supplied evidence; every non-reference UUID remains blank until hybrid discovery and public state-100 direct read independently confirm exact semantics, type, property, unit group, and unit, with unresolved row metadata updated together. | eu-recommendation-2021-2279-pef |
val_value_mode | inventory_amounts | The reference output alone uses fixed_value; measured records use foreground_record, derived balances use calculated_value, and no author-estimated range or default amount is permitted. | eu-recommendation-2021-2279-pef |
val_card_completeness | process_inventory | Every card shall have a non-empty description, selected flow, property and unit, amount rule, controlled value mode, specificity, basis, basis kind, evidence kind, collection protocol, and source ids. | eu-recommendation-2021-2279-pef |
val_mass_balance | foreground_mass_flows | Reception, slaughter, cutting, freezing, packaging, and wastewater volume or mass balances shall be reconciled and residuals explained without inserting a default yield. | ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef |
val_stage_energy | energy_inventory | Electricity, purchased steam, purchased hot water, natural gas, diesel, and LPG shall remain separate by stage, with shared-meter allocation drivers documented. | ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef |
val_refrigerants | refrigeration_inventory | Make-up and air emission shall be separately balanced for each named refrigerant at freezing and frozen storage; any additional site-used refrigerant requires its own atomic input and emission records before release. | ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef |
val_wastewater | wastewater_inventory | Each originating wastewater stream, treated wastewater, sludge, screenings, and each water emission shall be separately reconciled to flow and analytical records with destination disclosed. | ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef |
val_allocation | allocation | Every joint-output burden decision shall follow the declared hierarchy, disclose data and period, preserve waste status evidence, and reconcile allocated totals. | eu-recommendation-2021-2279-pef |
val_sources | evidence | Method claims shall cite only the three declared sources; foreground quantities shall trace to facility records rather than a source-derived default. | un-cpc-3-0; ec-jrc-sa-bref-2024; eu-recommendation-2021-2279-pef |
val_bilingual_alignment | localized_markdown | English and Chinese files shall preserve identical ordered process_id, row_id, direction, flow_type, UUID, controlled amount fields, collection protocol, and source-id sequences. | eu-recommendation-2021-2279-pef |
10. Published Dataset Profile
| Field | Value |
|---|---|
| dataset_role | Site-specific foreground data package for 1 kg net conforming frozen meat of horses or other equines at frozen-store release |
| downstream_use | Input to reviewed process datasets and lifecycle models that require a CPC 21138 foreground manufacturing inventory |
| allowed_use | Facility-specific gate-to-gate modelling; cradle-to-gate modelling when transparent upstream datasets are linked; comparative use only after equivalent scope, quality, allocation, and product qualifiers are confirmed |
| excluded_use | Representation of fresh or chilled equine meat, edible offal, non-equine meat, retail, cooking, consumption, or undisclosed generic industry averages |
| required_metadata | canonical PCR id; CPC code; reference UUID; species; carcass or cut form; bone state; frozen state; facility; geography; reporting period; technology; storage duration; storage condition; packaging; process inclusion; allocation; destinations |
| required_quality_disclosure | Primary-data coverage; meter allocation; mass-balance residuals; refrigerant balances; wastewater sampling; analytical methods; source records; zero evidence; data gaps; substitutions; allocation sensitivity; reviewer findings |
| update_trigger | Material change in product scope, facility technology, freezing system, refrigerant, packaging, storage condition, wastewater treatment, co-product destination, allocation relation, reporting period, or verified Tiangong identity |
11. Data Sources
| Source id | Type | Reference | Used for |
|---|---|---|---|
un-cpc-3-0 | official_guidance | United Nations Statistics Division. Central Product Classification Version 3.0 Structure and Explanatory Notes, subclass 21138, 30 June 2025. Retained raw: classifications/systems/cpc/3.0/raw/CPC_Ver_3.0_Structure_30Jun2025.csv. https://unstats.un.org/unsd/classifications/Econ/Download/In%20Text/CPC_Ver_3.0_Exp_Notes_30Jun2025.pdf | Exact frozen-equine-meat classification boundary and exclusion of fresh or chilled meat and edible offal |
ec-jrc-sa-bref-2024 | official_guidance | European Commission, Joint Research Centre. Best Available Techniques Reference Document for the Slaughterhouses, Animal By-products and/or Edible Co-products Industries. JRC135916, 2024. DOI: 10.2760/18199. https://publications.jrc.ec.europa.eu/repository/handle/JRC135916 | Reception, slaughter, dressing, cutting, chilling, freezing, sanitation, utilities, wastewater, co-product, waste, and emission process structure; no default quantity adopted |
eu-recommendation-2021-2279-pef | official_guidance | European Commission. Recommendation (EU) 2021/2279 on the use of the Environmental Footprint methods, consolidated text. https://eur-lex.europa.eu/eli/reco/2021/2279/2021-12-30/eng | Product-specific bill of materials, company-specific foreground data, complete life-cycle inventory, allocation hierarchy, data quality, transparency, and verification |
Raw downloads
These files are byte-identical to the canonical files for this revision in the repository.
Complete field inspector
Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.