Edible offal of buffalo, fresh, chilled or frozen · Process: On-site wastewater treatment (onsite_wastewater_treatment)
Edible offal of buffalo, fresh, chilled or frozen · Process: On-site wastewater treatment (onsite_wastewater_treatment): Electricity, medium voltage enters the On-site…
- Lifecycle status
- Candidate
- Content maturity
- Authored methodology
- Current version
- No published version
- Readiness
- Review required
- Last updated
Methodology and translation states come from the source record; publishing this website does not change their review status.
Content languages
Status, classification and source details
Readiness
- Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.
Classification mapping
Source
Process: On-site wastewater treatment (onsite_wastewater_treatment)
Inputs
Product flows
Wastewater-treatment electricity (wwt_electricity)
Electricity, medium voltage enters the On-site wastewater treatment boundary as the single wastewater-treatment electricity. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Electricity, medium voltage
- Flow property / unit: Energy / kWh
- Amount rule: Read electricity for this named stage from a submeter or allocate a reconciled shared meter with a documented operating-time, load, or throughput driver.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_consumables - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Treatment-polymer make-up water (wwt_makeup_water)
Process water enters the On-site wastewater treatment boundary as the single treatment-polymer make-up water. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Process water
- Flow property / unit: Volume / m3
- Amount rule: Read this water input from a dedicated calibrated meter or document a causal allocation from a reconciled shared meter.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_consumables - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Ferric-chloride coagulant (wwt_ferric_chloride)
Ferric chloride enters the On-site wastewater treatment boundary as the single ferric-chloride coagulant. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Ferric chloride
- Flow property / unit: Mass / kg
- Amount rule: Reconcile net use of this chemical from concentration, dosing, purchase, return, opening-stock, and closing-stock records.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_consumables - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Anionic-polyacrylamide flocculant (wwt_polyacrylamide)
Anionic polyacrylamide enters the On-site wastewater treatment boundary as the single anionic-polyacrylamide flocculant. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Anionic polyacrylamide
- Flow property / unit: Mass / kg
- Amount rule: Reconcile net use of this chemical from concentration, dosing, purchase, return, opening-stock, and closing-stock records.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_consumables - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Wastewater-treatment sodium hydroxide (wwt_sodium_hydroxide)
Sodium hydroxide enters the On-site wastewater treatment boundary as the single wastewater-treatment sodium hydroxide. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Sodium hydroxide
- Flow property / unit: Mass / kg
- Amount rule: Reconcile net use of this chemical from concentration, dosing, purchase, return, opening-stock, and closing-stock records.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_consumables - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Wastewater-treatment sulfuric acid (wwt_sulfuric_acid)
Sulfuric acid enters the On-site wastewater treatment boundary as the single wastewater-treatment sulfuric acid. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Sulfuric acid
- Flow property / unit: Mass / kg
- Amount rule: Reconcile net use of this chemical from concentration, dosing, purchase, return, opening-stock, and closing-stock records.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_consumables - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Waste flows
Holding-area washwater influent (wwt_holding_washwater)
Buffalo holding-area washwater enters the On-site wastewater treatment boundary as the single holding-area washwater influent. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Buffalo holding-area washwater
- Flow property / unit: Volume / m3
- Amount rule: Measure this named wastewater before mixing with a dedicated flow meter, tank record, or documented hydraulic allocation.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_influent - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Slaughter wastewater influent (wwt_slaughter_wastewater)
High-organic-load buffalo slaughter wastewater enters the On-site wastewater treatment boundary as the single slaughter wastewater influent. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: High-organic-load buffalo slaughter wastewater
- Flow property / unit: Volume / m3
- Amount rule: Measure this named wastewater before mixing with a dedicated flow meter, tank record, or documented hydraulic allocation.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_influent - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Buffalo liver washwater influent (wwt_liver_washwater)
Buffalo liver washwater enters the On-site wastewater treatment boundary as the single buffalo liver washwater influent. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Buffalo liver washwater
- Flow property / unit: Volume / m3
- Amount rule: Measure this named wastewater before mixing with a dedicated flow meter, tank record, or documented hydraulic allocation.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_influent - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Buffalo heart washwater influent (wwt_heart_washwater)
Buffalo heart washwater enters the On-site wastewater treatment boundary as the single buffalo heart washwater influent. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Buffalo heart washwater
- Flow property / unit: Volume / m3
- Amount rule: Measure this named wastewater before mixing with a dedicated flow meter, tank record, or documented hydraulic allocation.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_influent - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Buffalo kidney washwater influent (wwt_kidney_washwater)
Buffalo kidney washwater enters the On-site wastewater treatment boundary as the single buffalo kidney washwater influent. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Buffalo kidney washwater
- Flow property / unit: Volume / m3
- Amount rule: Measure this named wastewater before mixing with a dedicated flow meter, tank record, or documented hydraulic allocation.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_influent - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Buffalo tongue washwater influent (wwt_tongue_washwater)
Buffalo tongue washwater enters the On-site wastewater treatment boundary as the single buffalo tongue washwater influent. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Buffalo tongue washwater
- Flow property / unit: Volume / m3
- Amount rule: Measure this named wastewater before mixing with a dedicated flow meter, tank record, or documented hydraulic allocation.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_influent - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Buffalo brain washwater influent (wwt_brain_washwater)
Buffalo brain washwater enters the On-site wastewater treatment boundary as the single buffalo brain washwater influent. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Buffalo brain washwater
- Flow property / unit: Volume / m3
- Amount rule: Measure this named wastewater before mixing with a dedicated flow meter, tank record, or documented hydraulic allocation.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_influent - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Buffalo tripe washwater influent (wwt_tripe_washwater)
Buffalo tripe washwater enters the On-site wastewater treatment boundary as the single buffalo tripe washwater influent. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Buffalo tripe washwater
- Flow property / unit: Volume / m3
- Amount rule: Measure this named wastewater before mixing with a dedicated flow meter, tank record, or documented hydraulic allocation.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_influent - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Buffalo small intestine washwater influent (wwt_small_intestine_washwater)
Buffalo small-intestine washwater enters the On-site wastewater treatment boundary as the single buffalo small intestine washwater influent. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Buffalo small-intestine washwater
- Flow property / unit: Volume / m3
- Amount rule: Measure this named wastewater before mixing with a dedicated flow meter, tank record, or documented hydraulic allocation.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_influent - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Buffalo large intestine washwater influent (wwt_large_intestine_washwater)
Buffalo large-intestine washwater enters the On-site wastewater treatment boundary as the single buffalo large intestine washwater influent. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Buffalo large-intestine washwater
- Flow property / unit: Volume / m3
- Amount rule: Measure this named wastewater before mixing with a dedicated flow meter, tank record, or documented hydraulic allocation.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_influent - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Buffalo lung washwater influent (wwt_lung_washwater)
Buffalo lung washwater enters the On-site wastewater treatment boundary as the single buffalo lung washwater influent. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Buffalo lung washwater
- Flow property / unit: Volume / m3
- Amount rule: Measure this named wastewater before mixing with a dedicated flow meter, tank record, or documented hydraulic allocation.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_influent - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Buffalo spleen washwater influent (wwt_spleen_washwater)
Buffalo spleen washwater enters the On-site wastewater treatment boundary as the single buffalo spleen washwater influent. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Buffalo spleen washwater
- Flow property / unit: Volume / m3
- Amount rule: Measure this named wastewater before mixing with a dedicated flow meter, tank record, or documented hydraulic allocation.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_influent - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Chilling wastewater influent (wwt_chilling_wastewater)
Buffalo-offal chilling wastewater enters the On-site wastewater treatment boundary as the single chilling wastewater influent. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Buffalo-offal chilling wastewater
- Flow property / unit: Volume / m3
- Amount rule: Measure this named wastewater before mixing with a dedicated flow meter, tank record, or documented hydraulic allocation.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_influent - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Chilled-storage defrost influent (wwt_chill_defrost_wastewater)
Chilled-storage defrost wastewater enters the On-site wastewater treatment boundary as the single chilled-storage defrost influent. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Chilled-storage defrost wastewater
- Flow property / unit: Volume / m3
- Amount rule: Measure this named wastewater before mixing with a dedicated flow meter, tank record, or documented hydraulic allocation.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_influent - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Glazing wastewater influent (wwt_glazing_wastewater)
Buffalo-offal glazing wastewater enters the On-site wastewater treatment boundary as the single glazing wastewater influent. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Buffalo-offal glazing wastewater
- Flow property / unit: Volume / m3
- Amount rule: Measure this named wastewater before mixing with a dedicated flow meter, tank record, or documented hydraulic allocation.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_influent - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Frozen-storage defrost influent (wwt_freeze_defrost_wastewater)
Frozen-storage defrost wastewater enters the On-site wastewater treatment boundary as the single frozen-storage defrost influent. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Frozen-storage defrost wastewater
- Flow property / unit: Volume / m3
- Amount rule: Measure this named wastewater before mixing with a dedicated flow meter, tank record, or documented hydraulic allocation.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_influent - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Packaging washwater influent (wwt_packaging_washwater)
Buffalo-offal packaging washwater enters the On-site wastewater treatment boundary as the single packaging washwater influent. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Buffalo-offal packaging washwater
- Flow property / unit: Volume / m3
- Amount rule: Measure this named wastewater before mixing with a dedicated flow meter, tank record, or documented hydraulic allocation.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_influent - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Sodium-hydroxide sanitation influent (wwt_sodium_hydroxide_wastewater)
Sodium-hydroxide sanitation wastewater enters the On-site wastewater treatment boundary as the single sodium-hydroxide sanitation influent. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Sodium-hydroxide sanitation wastewater
- Flow property / unit: Volume / m3
- Amount rule: Measure this named wastewater before mixing with a dedicated flow meter, tank record, or documented hydraulic allocation.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_influent - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Nitric-acid sanitation influent (wwt_nitric_acid_wastewater)
Nitric-acid sanitation wastewater enters the On-site wastewater treatment boundary as the single nitric-acid sanitation influent. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Nitric-acid sanitation wastewater
- Flow property / unit: Volume / m3
- Amount rule: Measure this named wastewater before mixing with a dedicated flow meter, tank record, or documented hydraulic allocation.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_influent - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Phosphoric-acid sanitation influent (wwt_phosphoric_acid_wastewater)
Phosphoric-acid sanitation wastewater enters the On-site wastewater treatment boundary as the single phosphoric-acid sanitation influent. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Phosphoric-acid sanitation wastewater
- Flow property / unit: Volume / m3
- Amount rule: Measure this named wastewater before mixing with a dedicated flow meter, tank record, or documented hydraulic allocation.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_influent - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Peracetic-acid sanitation influent (wwt_peracetic_acid_wastewater)
Peracetic-acid sanitation wastewater enters the On-site wastewater treatment boundary as the single peracetic-acid sanitation influent. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Peracetic-acid sanitation wastewater
- Flow property / unit: Volume / m3
- Amount rule: Measure this named wastewater before mixing with a dedicated flow meter, tank record, or documented hydraulic allocation.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_influent - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Sodium-hypochlorite sanitation influent (wwt_hypochlorite_wastewater)
Sodium-hypochlorite sanitation wastewater enters the On-site wastewater treatment boundary as the single sodium-hypochlorite sanitation influent. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Sodium-hypochlorite sanitation wastewater
- Flow property / unit: Volume / m3
- Amount rule: Measure this named wastewater before mixing with a dedicated flow meter, tank record, or documented hydraulic allocation.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_influent - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Benzalkonium-chloride sanitation influent (wwt_benzalkonium_wastewater)
Benzalkonium-chloride sanitation wastewater enters the On-site wastewater treatment boundary as the single benzalkonium-chloride sanitation influent. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Benzalkonium-chloride sanitation wastewater
- Flow property / unit: Volume / m3
- Amount rule: Measure this named wastewater before mixing with a dedicated flow meter, tank record, or documented hydraulic allocation.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_influent - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Final-rinse sanitation influent (wwt_final_rinse_wastewater)
Final-rinse sanitation wastewater enters the On-site wastewater treatment boundary as the single final-rinse sanitation influent. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Final-rinse sanitation wastewater
- Flow property / unit: Volume / m3
- Amount rule: Measure this named wastewater before mixing with a dedicated flow meter, tank record, or documented hydraulic allocation.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_influent - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Elementary flows
Outputs
Product flows
Recovered wastewater grease (wwt_recovered_grease)
Recovered wastewater grease leaves the On-site wastewater treatment boundary as the single recovered wastewater grease. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Recovered wastewater grease
- Flow property / unit: Mass / kg
- Amount rule: Measure the separately recovered mass and retain its declared beneficial destination; classify the same mass only once as product or waste.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_residues - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Waste flows
Wastewater screenings (wwt_screenings)
Wastewater screenings leaves the On-site wastewater treatment boundary as the single wastewater screenings. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Wastewater screenings
- Flow property / unit: Mass / kg
- Amount rule: Measure this named waste separately by calibrated container weighing and destination records, preventing duplicate reporting as a recovered product.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_residues - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Dissolved-air-flotation sludge (wwt_daf_sludge)
Dissolved-air-flotation sludge leaves the On-site wastewater treatment boundary as the single dissolved-air-flotation sludge. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Dissolved-air-flotation sludge
- Flow property / unit: Mass / kg
- Amount rule: Measure this named waste separately by calibrated container weighing and destination records, preventing duplicate reporting as a recovered product.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_residues - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Biological wastewater sludge (wwt_biological_sludge)
Biological wastewater sludge leaves the On-site wastewater treatment boundary as the single biological wastewater sludge. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Biological wastewater sludge
- Flow property / unit: Mass / kg
- Amount rule: Measure this named waste separately by calibrated container weighing and destination records, preventing duplicate reporting as a recovered product.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_residues - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Discarded wastewater grease (wwt_discarded_grease)
Discarded wastewater grease leaves the On-site wastewater treatment boundary as the single discarded wastewater grease. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Discarded wastewater grease
- Flow property / unit: Mass / kg
- Amount rule: Measure this named waste separately by calibrated container weighing and destination records, preventing duplicate reporting as a recovered product.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_residues - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Elementary flows
Treated-effluent discharge (wwt_treated_effluent)
Treated wastewater effluent, to surface water leaves the On-site wastewater treatment boundary as the single treated-effluent discharge. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Treated wastewater effluent, to surface water
- Flow property / unit: Volume / m3
- Amount rule: Record final treated-effluent volume for the same discharge point and period used by the pollutant measurements.
- Value mode: Foreground record (
foreground_record) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Collected record (
collected_record) - Collection protocol:
cp_wwt_discharge - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Five-day biochemical-oxygen-demand discharge (wwt_bod5_water)
Biochemical oxygen demand, 5-day, to water leaves the On-site wastewater treatment boundary as the single five-day biochemical-oxygen-demand discharge. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Biochemical oxygen demand, 5-day, to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate this one water pollutant from discharge volume and a representative concentration measured for the same point and period.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wwt_discharge - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Chemical-oxygen-demand discharge (wwt_cod_water)
Chemical oxygen demand, to water leaves the On-site wastewater treatment boundary as the single chemical-oxygen-demand discharge. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Chemical oxygen demand, to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate this one water pollutant from discharge volume and a representative concentration measured for the same point and period.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wwt_discharge - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Total-suspended-solids discharge (wwt_tss_water)
Total suspended solids, to water leaves the On-site wastewater treatment boundary as the single total-suspended-solids discharge. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Total suspended solids, to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate this one water pollutant from discharge volume and a representative concentration measured for the same point and period.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wwt_discharge - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Total-nitrogen discharge (wwt_total_n_water)
Nitrogen, total, to water leaves the On-site wastewater treatment boundary as the single total-nitrogen discharge. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Nitrogen, total, to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate this one water pollutant from discharge volume and a representative concentration measured for the same point and period.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wwt_discharge - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Total-phosphorus discharge (wwt_total_p_water)
Phosphorus, total, to water leaves the On-site wastewater treatment boundary as the single total-phosphorus discharge. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Phosphorus, total, to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate this one water pollutant from discharge volume and a representative concentration measured for the same point and period.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wwt_discharge - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Chloride discharge (wwt_chloride_water)
Chloride, to water leaves the On-site wastewater treatment boundary as the single chloride discharge. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Chloride, to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate this one water pollutant from discharge volume and a representative concentration measured for the same point and period.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wwt_discharge - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Ammonium discharge (wwt_ammonium_water)
Ammonium, to water leaves the On-site wastewater treatment boundary as the single ammonium discharge. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Ammonium, to water
- Flow property / unit: Mass / kg
- Amount rule: Calculate this one water pollutant from discharge volume and a representative concentration measured for the same point and period.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wwt_discharge - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Biogenic methane release (wwt_biogenic_methane_air)
Methane, biogenic, to air leaves the On-site wastewater treatment boundary as the single biogenic methane release. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Methane, biogenic, to air
- Flow property / unit: Mass / kg
- Amount rule: Calculate this one gas release from a matched material balance or calibrated direct measurement while retaining origin and air compartment.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wwt_air_releases - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Biogenic carbon-dioxide release (wwt_biogenic_co2_air)
Carbon dioxide, biogenic, to air leaves the On-site wastewater treatment boundary as the single biogenic carbon-dioxide release. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Carbon dioxide, biogenic, to air
- Flow property / unit: Mass / kg
- Amount rule: Calculate this one gas release from a matched material balance or calibrated direct measurement while retaining origin and air compartment.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wwt_air_releases - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
Nitrous-oxide release (wwt_nitrous_oxide_air)
Nitrous oxide, to air leaves the On-site wastewater treatment boundary as the single nitrous-oxide release. Applicability and quantity are documented for this row without combining another exchange.
- Selected flow: Nitrous oxide, to air
- Flow property / unit: Mass / kg
- Amount rule: Calculate this one gas release from a matched material balance or calibrated direct measurement while retaining origin and air compartment.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg net qualified edible buffalo offal at the facility gate, excluding packaging mass
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_wwt_air_releases - Sources:
ec-jrc-sa-bref-jrc135916;eu-pef-2021-2279
7. Allocation and Co-product Handling
| rule_id | Applies to | Rule | source_ids |
|---|---|---|---|
allocation_subdivision | Shared slaughter and utility operations | Prefer measured process subdivision and direct assignment to the organ batch before applying an allocation. | eu-pef-2021-2279 |
allocation_shared_slaughter | Carcass, edible organs, blood, hide, head frame, horn, hoof, fat, and tail | When shared burdens remain, use a documented physical relationship reflecting the process; use mass only when it is defensible, and disclose any economic relationship used after the applicable hierarchy is evaluated. | ec-jrc-sa-bref-jrc135916; eu-pef-2021-2279 |
allocation_product_waste_status | Every recovered material | Classify a measured quantity once as product or waste according to legal status and documented destination; never duplicate the same mass in both roles. | ec-jrc-sa-bref-jrc135916; eu-pef-2021-2279 |
allocation_organ_mass_balance | Slaughter and organ preparation | Reconcile accepted live mass with carcass, each organ, other recovered products, condemned material, contents, residues, wastewater solids, inventory change, and documented measurement difference. | ec-jrc-sa-bref-jrc135916; eu-pef-2021-2279 |
allocation_waste_treatment | Waste and wastewater | Assign foreground collection and on-site treatment activity to this system, disclose the off-site treatment boundary, and report any credit separately. | eu-pef-2021-2279 |
allocation_reusable_packaging | Reusable crate and wooden pallet | Allocate only measured replacement or loss consumption through actual issue and return records; disclose lifetime and loss assumptions. | eu-pef-2021-2279 |
8. Foreground Data Collection, Calculation, and Quality Rules
Data Collection Protocols
| protocol_id | process_id | flow_role | record_type | raw_fields | collection_method | unit | frequency | temporal_coverage | site_scope | aggregation_rule | quality_evidence |
|---|---|---|---|---|---|---|---|---|---|---|---|
cp_receipt_live_mass | buffalo_receipt_and_holding | Live-buffalo mass at the named boundary | Livestock scale or weighbridge record | row_id; batch_id; gross_mass; tare_mass; net_mass; unit; scale_id; timestamp | Measure gross and tare on calibrated equipment, calculate net live mass, and reconcile receipt with accepted, mortality, and slaughter records. | kg | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Scale calibration; weigh ticket; animal batch register; reconciliation |
cp_receipt_utilities | buffalo_receipt_and_holding | One water, electricity, steam, hot-water, or fuel input | Meter, supplier, stock, tank, or cylinder record | row_id; meter_or_stock_id; opening_reading; closing_reading; receipt; return; unit; allocation_driver; batch_id | Collect each carrier independently, reconcile purchases and stock, and document any shared-meter allocation without combining carriers. | m3, kWh, MJ, or kg as declared | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Meter calibration; invoice; stock ledger; allocation worksheet |
cp_receipt_residues | buffalo_receipt_and_holding | One named waste, wastewater, reject, sludge, grease, or residue | Scale, flow-meter, container, manifest, and destination record | row_id; batch_id; material_identity; gross_quantity; tare_quantity; net_quantity; unit; destination; legal_status; timestamp | Measure the named stream independently, retain its destination and legal status, and reconcile it without duplicate product classification. | kg or m3 as declared | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Scale or meter calibration; waste record; manifest; destination receipt; balance reconciliation |
cp_slaughter_live_mass | slaughter_bleeding_and_organ_recovery | Live-buffalo mass at the named boundary | Livestock scale or weighbridge record | row_id; batch_id; gross_mass; tare_mass; net_mass; unit; scale_id; timestamp | Measure gross and tare on calibrated equipment, calculate net live mass, and reconcile receipt with accepted, mortality, and slaughter records. | kg | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Scale calibration; weigh ticket; animal batch register; reconciliation |
cp_slaughter_utilities | slaughter_bleeding_and_organ_recovery | One water, electricity, steam, hot-water, or fuel input | Meter, supplier, stock, tank, or cylinder record | row_id; meter_or_stock_id; opening_reading; closing_reading; receipt; return; unit; allocation_driver; batch_id | Collect each carrier independently, reconcile purchases and stock, and document any shared-meter allocation without combining carriers. | m3, kWh, MJ, or kg as declared | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Meter calibration; invoice; stock ledger; allocation worksheet |
cp_slaughter_products | slaughter_bleeding_and_organ_recovery | One organ-specific or co-product mass | Calibrated scale and batch transfer record | row_id; organ_or_material; state; batch_id; gross_mass; tare_mass; net_mass; unit; scale_id | Weigh each named organ or recovered output separately and link its identity, state, disposition, and batch. | kg | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Scale calibration; batch sheet; release or destination record; mass balance |
cp_slaughter_coproducts | slaughter_bleeding_and_organ_recovery | One organ-specific or co-product mass | Calibrated scale and batch transfer record | row_id; organ_or_material; state; batch_id; gross_mass; tare_mass; net_mass; unit; scale_id | Weigh each named organ or recovered output separately and link its identity, state, disposition, and batch. | kg | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Scale calibration; batch sheet; release or destination record; mass balance |
cp_slaughter_residues | slaughter_bleeding_and_organ_recovery | One named waste, wastewater, reject, sludge, grease, or residue | Scale, flow-meter, container, manifest, and destination record | row_id; batch_id; material_identity; gross_quantity; tare_quantity; net_quantity; unit; destination; legal_status; timestamp | Measure the named stream independently, retain its destination and legal status, and reconcile it without duplicate product classification. | kg or m3 as declared | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Scale or meter calibration; waste record; manifest; destination receipt; balance reconciliation |
cp_slaughter_wastewater | slaughter_bleeding_and_organ_recovery | One named wastewater stream or one discharge parameter | Flow-meter, composite-sample, laboratory, and discharge record | row_id; sampling_point; start_time; end_time; volume; concentration; analyte; unit; method; detection_limit | Measure stream volume before mixing where feasible and pair representative concentration results with the same point and reporting period. | m3 or kg as declared | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Meter calibration; sampling plan; chain of custody; laboratory report; discharge log |
cp_slaughter_air_emissions | slaughter_bleeding_and_organ_recovery | One named emission to air | Fuel, material-balance, stack, direct-measurement, and calculation record | row_id; source_row_id; activity_quantity; activity_unit; factor_or_measurement; factor_unit; origin; calculated_mass; period | Calculate or measure each emitted substance separately and retain the matched activity, origin, compartment, factor provenance, and period. | kg | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Matched activity record; stack or service record; factor evidence; calculation review |
cp_prep_organ_mass | offal_separation_trimming_and_washing | One organ-specific or co-product mass | Calibrated scale and batch transfer record | row_id; organ_or_material; state; batch_id; gross_mass; tare_mass; net_mass; unit; scale_id | Weigh each named organ or recovered output separately and link its identity, state, disposition, and batch. | kg | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Scale calibration; batch sheet; release or destination record; mass balance |
cp_prep_utilities | offal_separation_trimming_and_washing | One water, electricity, steam, hot-water, or fuel input | Meter, supplier, stock, tank, or cylinder record | row_id; meter_or_stock_id; opening_reading; closing_reading; receipt; return; unit; allocation_driver; batch_id | Collect each carrier independently, reconcile purchases and stock, and document any shared-meter allocation without combining carriers. | m3, kWh, MJ, or kg as declared | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Meter calibration; invoice; stock ledger; allocation worksheet |
cp_prep_solid_residues | offal_separation_trimming_and_washing | One named solid waste, reject, or recovered residue | Container scale, waste log, manifest, and destination record | row_id; batch_id; material_identity; container_id; gross_mass; tare_mass; net_mass; destination; legal_status; timestamp | Measure the named material separately and record destination and legal status so one mass is not reported as both product and waste. | kg | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Scale calibration; waste log; manifest; destination receipt; mass balance |
cp_prep_washwater | offal_separation_trimming_and_washing | One atomic exchange linked to its row_id | Foreground operating record | row_id; batch_id; timestamp; quantity; unit; record_id; instrument_id | Capture the named exchange separately and preserve an auditable link to its original record. | Unit declared by the flow card | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Instrument status; source record; batch reconciliation; responsible-person approval |
cp_prep_air_emissions | offal_separation_trimming_and_washing | One named emission to air | Fuel, material-balance, stack, direct-measurement, and calculation record | row_id; source_row_id; activity_quantity; activity_unit; factor_or_measurement; factor_unit; origin; calculated_mass; period | Calculate or measure each emitted substance separately and retain the matched activity, origin, compartment, factor provenance, and period. | kg | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Matched activity record; stack or service record; factor evidence; calculation review |
cp_fresh_organ_mass | fresh_offal_conditioning | One organ-specific or co-product mass | Calibrated scale and batch transfer record | row_id; organ_or_material; state; batch_id; gross_mass; tare_mass; net_mass; unit; scale_id | Weigh each named organ or recovered output separately and link its identity, state, disposition, and batch. | kg | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Scale calibration; batch sheet; release or destination record; mass balance |
cp_fresh_utilities | fresh_offal_conditioning | One water, electricity, steam, hot-water, or fuel input | Meter, supplier, stock, tank, or cylinder record | row_id; meter_or_stock_id; opening_reading; closing_reading; receipt; return; unit; allocation_driver; batch_id | Collect each carrier independently, reconcile purchases and stock, and document any shared-meter allocation without combining carriers. | m3, kWh, MJ, or kg as declared | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Meter calibration; invoice; stock ledger; allocation worksheet |
cp_fresh_rejects | fresh_offal_conditioning | One named solid waste, reject, or recovered residue | Container scale, waste log, manifest, and destination record | row_id; batch_id; material_identity; container_id; gross_mass; tare_mass; net_mass; destination; legal_status; timestamp | Measure the named material separately and record destination and legal status so one mass is not reported as both product and waste. | kg | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Scale calibration; waste log; manifest; destination receipt; mass balance |
cp_chill_organ_mass | chilling_and_chilled_storage | One organ-specific or co-product mass | Calibrated scale and batch transfer record | row_id; organ_or_material; state; batch_id; gross_mass; tare_mass; net_mass; unit; scale_id | Weigh each named organ or recovered output separately and link its identity, state, disposition, and batch. | kg | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Scale calibration; batch sheet; release or destination record; mass balance |
cp_chill_utilities | chilling_and_chilled_storage | One water, electricity, steam, hot-water, or fuel input | Meter, supplier, stock, tank, or cylinder record | row_id; meter_or_stock_id; opening_reading; closing_reading; receipt; return; unit; allocation_driver; batch_id | Collect each carrier independently, reconcile purchases and stock, and document any shared-meter allocation without combining carriers. | m3, kWh, MJ, or kg as declared | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Meter calibration; invoice; stock ledger; allocation worksheet |
cp_chill_refrigerants | chilling_and_chilled_storage | One substance-specific refrigerant make-up or release | Cylinder weight, stock, recovery, transfer, and service record | row_id; substance; equipment_id; opening_stock; receipts; recovered_mass; transferred_mass; closing_stock; direct_loss; unit | Maintain an independent mass balance for this refrigerant substance and reconcile it to recovery and service events. | kg | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Cylinder-scale calibration; service log; invoice; recovery certificate; mass-balance review |
cp_chill_residues | chilling_and_chilled_storage | One named waste, wastewater, reject, sludge, grease, or residue | Scale, flow-meter, container, manifest, and destination record | row_id; batch_id; material_identity; gross_quantity; tare_quantity; net_quantity; unit; destination; legal_status; timestamp | Measure the named stream independently, retain its destination and legal status, and reconcile it without duplicate product classification. | kg or m3 as declared | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Scale or meter calibration; waste record; manifest; destination receipt; balance reconciliation |
cp_freeze_organ_mass | freezing_and_frozen_storage | One organ-specific or co-product mass | Calibrated scale and batch transfer record | row_id; organ_or_material; state; batch_id; gross_mass; tare_mass; net_mass; unit; scale_id | Weigh each named organ or recovered output separately and link its identity, state, disposition, and batch. | kg | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Scale calibration; batch sheet; release or destination record; mass balance |
cp_freeze_utilities | freezing_and_frozen_storage | One water, electricity, steam, hot-water, or fuel input | Meter, supplier, stock, tank, or cylinder record | row_id; meter_or_stock_id; opening_reading; closing_reading; receipt; return; unit; allocation_driver; batch_id | Collect each carrier independently, reconcile purchases and stock, and document any shared-meter allocation without combining carriers. | m3, kWh, MJ, or kg as declared | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Meter calibration; invoice; stock ledger; allocation worksheet |
cp_freeze_refrigerants | freezing_and_frozen_storage | One substance-specific refrigerant make-up or release | Cylinder weight, stock, recovery, transfer, and service record | row_id; substance; equipment_id; opening_stock; receipts; recovered_mass; transferred_mass; closing_stock; direct_loss; unit | Maintain an independent mass balance for this refrigerant substance and reconcile it to recovery and service events. | kg | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Cylinder-scale calibration; service log; invoice; recovery certificate; mass-balance review |
cp_freeze_residues | freezing_and_frozen_storage | One named waste, wastewater, reject, sludge, grease, or residue | Scale, flow-meter, container, manifest, and destination record | row_id; batch_id; material_identity; gross_quantity; tare_quantity; net_quantity; unit; destination; legal_status; timestamp | Measure the named stream independently, retain its destination and legal status, and reconcile it without duplicate product classification. | kg or m3 as declared | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Scale or meter calibration; waste record; manifest; destination receipt; balance reconciliation |
cp_packaging_organ_mass | packaging_and_release | One organ-specific or co-product mass | Calibrated scale and batch transfer record | row_id; organ_or_material; state; batch_id; gross_mass; tare_mass; net_mass; unit; scale_id | Weigh each named organ or recovered output separately and link its identity, state, disposition, and batch. | kg | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Scale calibration; batch sheet; release or destination record; mass balance |
cp_packaging_energy | packaging_and_release | One water, electricity, steam, hot-water, or fuel input | Meter, supplier, stock, tank, or cylinder record | row_id; meter_or_stock_id; opening_reading; closing_reading; receipt; return; unit; allocation_driver; batch_id | Collect each carrier independently, reconcile purchases and stock, and document any shared-meter allocation without combining carriers. | m3, kWh, MJ, or kg as declared | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Meter calibration; invoice; stock ledger; allocation worksheet |
cp_packaging_components | packaging_and_release | One chemical, treatment consumable, packaging component, or packaging gas | Purchase, dosing, issue, return, and stock record | row_id; material_identity; grade_or_concentration; opening_stock; receipts; issued_quantity; returns; closing_stock; unit; batch_id | Reconcile the named material independently and link net consumption to the applicable organ batch. | kg, m3, kWh, or MJ as declared | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Invoice; specification; dosing or issue record; stock reconciliation |
cp_packaging_gases | packaging_and_release | One chemical, treatment consumable, packaging component, or packaging gas | Purchase, dosing, issue, return, and stock record | row_id; material_identity; grade_or_concentration; opening_stock; receipts; issued_quantity; returns; closing_stock; unit; batch_id | Reconcile the named material independently and link net consumption to the applicable organ batch. | kg, m3, kWh, or MJ as declared | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Invoice; specification; dosing or issue record; stock reconciliation |
cp_packaging_waste | packaging_and_release | One named waste, wastewater, reject, sludge, grease, or residue | Scale, flow-meter, container, manifest, and destination record | row_id; batch_id; material_identity; gross_quantity; tare_quantity; net_quantity; unit; destination; legal_status; timestamp | Measure the named stream independently, retain its destination and legal status, and reconcile it without duplicate product classification. | kg or m3 as declared | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Scale or meter calibration; waste record; manifest; destination receipt; balance reconciliation |
cp_packaging_gas_releases | packaging_and_release | One named emission to air | Fuel, material-balance, stack, direct-measurement, and calculation record | row_id; source_row_id; activity_quantity; activity_unit; factor_or_measurement; factor_unit; origin; calculated_mass; period | Calculate or measure each emitted substance separately and retain the matched activity, origin, compartment, factor provenance, and period. | kg | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Matched activity record; stack or service record; factor evidence; calculation review |
cp_sanitation_utilities | cleaning_and_disinfection | One water, electricity, steam, hot-water, or fuel input | Meter, supplier, stock, tank, or cylinder record | row_id; meter_or_stock_id; opening_reading; closing_reading; receipt; return; unit; allocation_driver; batch_id | Collect each carrier independently, reconcile purchases and stock, and document any shared-meter allocation without combining carriers. | m3, kWh, MJ, or kg as declared | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Meter calibration; invoice; stock ledger; allocation worksheet |
cp_sanitation_chemicals | cleaning_and_disinfection | One chemical, treatment consumable, packaging component, or packaging gas | Purchase, dosing, issue, return, and stock record | row_id; material_identity; grade_or_concentration; opening_stock; receipts; issued_quantity; returns; closing_stock; unit; batch_id | Reconcile the named material independently and link net consumption to the applicable organ batch. | kg, m3, kWh, or MJ as declared | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Invoice; specification; dosing or issue record; stock reconciliation |
cp_sanitation_wastewater | cleaning_and_disinfection | One named waste, wastewater, reject, sludge, grease, or residue | Scale, flow-meter, container, manifest, and destination record | row_id; batch_id; material_identity; gross_quantity; tare_quantity; net_quantity; unit; destination; legal_status; timestamp | Measure the named stream independently, retain its destination and legal status, and reconcile it without duplicate product classification. | kg or m3 as declared | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Scale or meter calibration; waste record; manifest; destination receipt; balance reconciliation |
cp_sanitation_air_emissions | cleaning_and_disinfection | One named emission to air | Fuel, material-balance, stack, direct-measurement, and calculation record | row_id; source_row_id; activity_quantity; activity_unit; factor_or_measurement; factor_unit; origin; calculated_mass; period | Calculate or measure each emitted substance separately and retain the matched activity, origin, compartment, factor provenance, and period. | kg | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Matched activity record; stack or service record; factor evidence; calculation review |
cp_wwt_consumables | onsite_wastewater_treatment | One chemical, treatment consumable, packaging component, or packaging gas | Purchase, dosing, issue, return, and stock record | row_id; material_identity; grade_or_concentration; opening_stock; receipts; issued_quantity; returns; closing_stock; unit; batch_id | Reconcile the named material independently and link net consumption to the applicable organ batch. | kg, m3, kWh, or MJ as declared | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Invoice; specification; dosing or issue record; stock reconciliation |
cp_wwt_influent | onsite_wastewater_treatment | One named wastewater stream or one discharge parameter | Flow-meter, composite-sample, laboratory, and discharge record | row_id; sampling_point; start_time; end_time; volume; concentration; analyte; unit; method; detection_limit | Measure stream volume before mixing where feasible and pair representative concentration results with the same point and reporting period. | m3 or kg as declared | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Meter calibration; sampling plan; chain of custody; laboratory report; discharge log |
cp_wwt_residues | onsite_wastewater_treatment | One named waste, wastewater, reject, sludge, grease, or residue | Scale, flow-meter, container, manifest, and destination record | row_id; batch_id; material_identity; gross_quantity; tare_quantity; net_quantity; unit; destination; legal_status; timestamp | Measure the named stream independently, retain its destination and legal status, and reconcile it without duplicate product classification. | kg or m3 as declared | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Scale or meter calibration; waste record; manifest; destination receipt; balance reconciliation |
cp_wwt_discharge | onsite_wastewater_treatment | One named wastewater stream or one discharge parameter | Flow-meter, composite-sample, laboratory, and discharge record | row_id; sampling_point; start_time; end_time; volume; concentration; analyte; unit; method; detection_limit | Measure stream volume before mixing where feasible and pair representative concentration results with the same point and reporting period. | m3 or kg as declared | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Meter calibration; sampling plan; chain of custody; laboratory report; discharge log |
cp_wwt_air_releases | onsite_wastewater_treatment | One named emission to air | Fuel, material-balance, stack, direct-measurement, and calculation record | row_id; source_row_id; activity_quantity; activity_unit; factor_or_measurement; factor_unit; origin; calculated_mass; period | Calculate or measure each emitted substance separately and retain the matched activity, origin, compartment, factor provenance, and period. | kg | Each batch with reporting-period reconciliation | Complete declared foreground reporting period | Foreground slaughterhouse or offal-processing facility | Sum only records assigned to this process and row_id, prevent duplicate assignment, then normalize by net qualified reference-product mass. | Matched activity record; stack or service record; factor evidence; calculation review |
Calculation Rules
| rule_id | Applies to | Formula or rule | Inputs | Output | source_ids |
|---|---|---|---|---|---|
calc_reference_normalization | Every non-reference row | Divide the batch or reporting-period exchange by the matched net mass of qualified reference product; retain unrounded numerator and denominator. | row-specific quantity; net qualified organ mass | Quantity per 1 kg reference product | eu-pef-2021-2279 |
calc_organ_mass_balance | Receipt, slaughter, preparation, state conditioning, and packaging | Reconcile measured input with organ outputs, carcass products, co-products, rejects, wastes, inventory change, and documented measurement difference; do not invent a balancing flow. | calibrated mass records; inventory change | Disclosed organ and facility mass balance | ec-jrc-sa-bref-jrc135916; eu-pef-2021-2279 |
calc_state_route | Fresh, chilled, and frozen branches | Assign a reference batch to one state route from release records; normalize only that branch and reject any calculation that mixes branch quantities. | organ batch id; release state; branch records | One state-specific foreground inventory | eu-pef-2021-2279 |
calc_combustion_release | Each combustion-pollutant row | Multiply the separately collected fuel quantity by a documented facility-specific pollutant factor, or use a matched direct stack result; preserve source, unit, and period. | fuel quantity; pollutant factor or stack result | Pollutant mass to air | eu-pef-2021-2279 |
calc_refrigerant_loss | Each refrigerant-emission row | Calculate opening stock plus receipts minus closing stock, recovered mass, and transfers for one substance, then reconcile with service-loss records. | substance-specific stock and service records | Refrigerant mass to air | eu-pef-2021-2279 |
calc_shared_meter | Shared utility meters | Use a documented causal driver only after evaluating direct submetering; preserve the unallocated total and allocation worksheet. | shared-meter quantity; operating time, load, or throughput | Process-specific utility quantity | eu-pef-2021-2279 |
calc_packaging_consumption | Each packaging component | Calculate opening stock plus receipts minus closing stock, returns, and unused transfers; for reusable items use measured replacement or loss. | component-specific stock, issue, return, and loss records | Component mass per reference product | eu-pef-2021-2279 |
calc_effluent_load | Each wastewater-pollutant row | Multiply matched discharge volume by a representative measured concentration from the same point and period with explicit unit conversion. | discharge volume; measured concentration | Pollutant mass to water | ec-jrc-sa-bref-jrc135916; eu-pef-2021-2279 |
Data Quality Requirements
| requirement_id | Applies to | Requirement | Evidence |
|---|---|---|---|
dq_reference_identity | Reference product | Demonstrate CPC 21152, buffalo origin, exact organ identity, human-consumption edibility, one declared state, and exclusion of packaging mass. | Product specification; veterinary or food-safety release; batch record; reference UUID |
dq_state_traceability | Fresh, chilled, or frozen route | Preserve branch selection, handling duration, temperature records, and proof that the same reference batch did not enter another state branch. | Time record; temperature log; route record; release record |
dq_primary_foreground | Foreground operations | Use facility-specific primary records for every material, utility, organ, co-product, waste, wastewater, refrigerant, and direct release. | Meters; scales; invoices; stock ledgers; service logs; manifests; laboratory reports |
dq_temporal_coverage | Reporting period | Cover a representative period including slaughter, organ preparation, selected state conditioning, packaging, sanitation, storage, and treatment variability. | Dated records; production calendar; completeness reconciliation |
dq_atomic_inventory | Inventory rows | Preserve one exact exchange per row and maintain row-level closure with manifest unresolved-UUID review entries. | Ordered row-id audit; UUID register; source-record crosswalk |
dq_mass_water_balance | Facility balances | Reconcile organ and facility mass balances plus water intake, wastewater transfer, treatment, and discharge; explain material residuals with evidence. | Mass-balance worksheet; water-balance worksheet; reviewer approval |
dq_refrigerant_balance | Chilling and freezing systems | Identify each refrigerant and reconcile make-up, recovery, transfer, inventory, and release for the same period; retain R-744 origin. | Cylinder weights; service logs; purchase and recovery records; substance balance |
dq_calculation_traceability | Calculated values | Retain raw values, units, factors, formulas, conversions, factor provenance, and exact batch or period links. | Reproducible calculation file; source-record ids; calculation review |
dq_independent_review | Dataset package | Review scope, reference flow, state branch, organ identity, completeness, allocation, calculations, data quality, and exclusions before lifecycle promotion. | Validation record; reviewer identity; issue disposition |
9. Validation Rules
| rule_id | Applies to | Rule | source_ids |
|---|---|---|---|
validate_reference_uuid | Reference flow | Require UUID ed9e2fcf-3bf3-4b09-a893-dc5250a65f5c, Product flow type, exact CPC 21152 scope, Mass property 93a60a56-a3c8-11da-a746-0800200b9a66, Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66, kg, and exactly 1 kg net output. | unsd-cpc-3-21152 |
validate_product_scope | Product identity | Reject skeletal meat, inedible offal, mixed-species offal, non-buffalo offal, and cooked, cured, smoked, dried, salted, or further-preserved products. | unsd-cpc-3-21152 |
validate_exact_organ | Organ identity | Require one exactly named organ for the reference lot and an atomic row in every applicable process; reject an “other offal” selected flow. | ec-jrc-sa-bref-jrc135916; eu-pef-2021-2279 |
validate_state_exclusivity | State routes | Require exactly one of fresh, chilled, or frozen for each reference lot and reject mixed-state normalization. | ec-jrc-sa-bref-jrc135916; eu-pef-2021-2279 |
validate_process_coverage | Process inventory | Require all required processes and documented inclusion decisions for the three state branches and on-site wastewater treatment. | ec-jrc-sa-bref-jrc135916; eu-pef-2021-2279 |
validate_atomic_exchange | Inventory | Reject combined carriers, chemicals, packaging components, organs, co-products, wastes, wastewater pollutants, or emissions in one selected flow. | ec-jrc-sa-bref-jrc135916; eu-pef-2021-2279 |
validate_fixed_value | Amount modes | Require the reference output as the sole fixed value and prohibit invented fixed quantities or ranges for non-reference rows. | eu-pef-2021-2279 |
validate_mass_allocation | Slaughter and organ preparation | Require mass reconciliation, product-versus-waste exclusivity, allocation disclosure, and sensitivity where allocation materially affects results. | ec-jrc-sa-bref-jrc135916; eu-pef-2021-2279 |
validate_refrigerants | Chilled and frozen routes | Require substance-specific make-up and release records for every refrigerant present and separate fossil from biogenic R-744 release. | eu-pef-2021-2279 |
validate_wastewater | Wastewater | Require named wastewater inputs, matched discharge volume and concentration, and documented off-site transfer when on-site treatment is absent. | ec-jrc-sa-bref-jrc135916; eu-pef-2021-2279 |
validate_unresolved_uuid | Non-reference identities | Permit a blank UUID only for a physically specific row with matching selected_flow_candidates and rejected_candidates under that row_id in manifest.yaml. | eu-pef-2021-2279 |
validate_data_quality | Foreground package | Require primary-record traceability, representative temporal coverage, reproducible calculations, complete disclosures, and independent review evidence. | eu-pef-2021-2279 |
10. Published Dataset Profile
| Field | Value |
|---|---|
| dataset_role | Foreground unit-process package for 1 kg net qualified edible buffalo offal in one declared fresh, chilled, or frozen state |
| downstream_use | secondary_dataset; background_dataset |
| allowed_use | Product carbon footprinting, life-cycle assessment, supplier exchange, facility improvement, and reviewed aggregation when organ and state qualifiers remain explicit |
| excluded_use | Direct representation of skeletal meat, inedible offal, mixed-species offal, non-buffalo offal, husbandry, inbound transport, retail, preparation, consumption, or further-preserved products |
| required_metadata | PCR id; CPC code; reference UUID; buffalo taxon; exact organ; edibility status; state; time and temperature; trimming; packaging; net mass; facility; geography; technology; batch; period; allocation; co-product destinations; refrigerants; wastewater route; unresolved UUID register |
| required_quality_disclosure | Primary-data share; meter and scale coverage; shared-record allocations; organ and facility mass balances; water balance; refrigerant balance; state-route proof; data gaps; calculation provenance; validation findings |
| update_trigger | Change in organ mix, buffalo taxon, edibility rules, state route, chilling or freezing technology, refrigerant, thermal supply, packaging, sanitation chemistry, wastewater route, allocation, co-product legal status, facility configuration, or representative period |
11. Data Sources
| Source id | Type | Reference | Used for |
|---|---|---|---|
unsd-cpc-3-21152 | Dataset (dataset) | United Nations Statistics Division, Central Product Classification Version 3.0, code 21152, retained raw file CPC_Ver_3.0_Structure_30Jun2025.csv, SHA-256 5cd2c1c4890dd6be16af48e9bb940fed48efff9865f39ff15edaa921da25fb7c, retrieved 2026-06-23T08:55:39.235Z; https://unstats.un.org/unsd/classifications/Econ/Download/In%20Text/CPC_Ver_3.0_Structure_30Jun2025.csv | Exact category boundary for edible buffalo offal in fresh, chilled, or frozen states and separation from neighboring categories |
ec-jrc-sa-bref-jrc135916 | Official guidance (official_guidance) | European Commission Joint Research Centre, Best Available Techniques Reference Document for the Slaughterhouses, Animal By-products and Edible Co-products Industries, JRC135916, DOI 10.2760/18199; https://publications.jrc.ec.europa.eu/repository/handle/JRC135916 | Receipt, slaughter, bleeding, evisceration, organ and co-product recovery, cooling, freezing, cleaning, utilities, wastewater, residues, emissions, and foreground process structure; no quantitative default imported |
eu-pef-2021-2279 | Official guidance (official_guidance) | Commission Recommendation (EU) 2021/2279 on the use of the Environmental Footprint methods, consolidated text; https://eur-lex.europa.eu/eli/reco/2021/2279/2021-12-30/eng | Product-specific inventory, company-specific foreground data, completeness, allocation, transparency, data quality, calculation traceability, and verification |
Raw downloads
These files are byte-identical to the canonical files for this revision in the repository.
Complete field inspector
Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.