Unworked continuously rolled patterned soda-lime glass sheets · Process: Component-specific package custody and actual repair (packaging)
- Lifecycle status
- Candidate
- Content maturity
- Authored methodology
- Current version
- 0.1.0Last updated
- Readiness
- Review required
Methodology and translation states come from the source record; publishing this website does not change their review status.
Content languages
Status, classification and source details
Readiness
- Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.
Classification mapping
Source
Process: Component-specific package custody and actual repair (packaging)
Inputs
Product flows
New package purchase: Wooden glass-sheet shipping crate (crate_purchase)
One actual wooden glass-sheet shipping crate component; condition new package purchase. Whole supplied article includes actual composition, treatment/coating/adhesive if present and tare/moisture. Record direction-specific unnormalized physical movement and history; keep opening/closing empty, attached WIP/FG and reusable states separately. Internal reuse cancels, not another purchase. Real repair needs separate new component input and removed old component/waste/vector, no guessed crate weight. No UUID is adopted; retain this specific physical/chemical identity and confirm actual supply/used state, chemistry, provider and exact unit chain before dataset finalization.
- Selected flow: Wooden glass-sheet shipping crate
- Flow property / unit: Mass / kg
- Amount rule: Use the single stored normalization result from section8; the linked protocol first retains undivided actual raw quantities and stock/attribution evidence.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg reference flow
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging - Sources:
jrc-glass-bref-2013;ilcd-attributional-2010
Package received attached to inbound supplies: Wooden glass-sheet shipping crate (crate_supplier_inbound)
One actual wooden glass-sheet shipping crate component; condition package received attached to inbound supplies. Whole supplied article includes actual composition, treatment/coating/adhesive if present and tare/moisture. Record direction-specific unnormalized physical movement and history; keep opening/closing empty, attached WIP/FG and reusable states separately. Internal reuse cancels, not another purchase. Real repair needs separate new component input and removed old component/waste/vector, no guessed crate weight. No UUID is adopted; retain this specific physical/chemical identity and confirm actual supply/used state, chemistry, provider and exact unit chain before dataset finalization.
- Selected flow: Wooden glass-sheet shipping crate
- Flow property / unit: Mass / kg
- Amount rule: Use the single stored normalization result from section8; the linked protocol first retains undivided actual raw quantities and stock/attribution evidence.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg reference flow
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging - Sources:
jrc-glass-bref-2013;ilcd-attributional-2010
External package return received: Wooden glass-sheet shipping crate (crate_return_received)
One actual wooden glass-sheet shipping crate component; condition external package return received. Whole supplied article includes actual composition, treatment/coating/adhesive if present and tare/moisture. Record direction-specific unnormalized physical movement and history; keep opening/closing empty, attached WIP/FG and reusable states separately. Internal reuse cancels, not another purchase. Real repair needs separate new component input and removed old component/waste/vector, no guessed crate weight. No UUID is adopted; retain this specific physical/chemical identity and confirm actual supply/used state, chemistry, provider and exact unit chain before dataset finalization.
- Selected flow: Wooden glass-sheet shipping crate
- Flow property / unit: Mass / kg
- Amount rule: Use the single stored normalization result from section8; the linked protocol first retains undivided actual raw quantities and stock/attribution evidence.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg reference flow
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging - Sources:
jrc-glass-bref-2013;ilcd-attributional-2010
New package purchase: Cork glass-sheet separator pad (pad_purchase)
One actual cork glass-sheet separator pad component; condition new package purchase. Whole supplied article includes actual composition, treatment/coating/adhesive if present and tare/moisture. Record direction-specific unnormalized physical movement and history; keep opening/closing empty, attached WIP/FG and reusable states separately. Internal reuse cancels, not another purchase. Real repair needs separate new component input and removed old component/waste/vector, no guessed crate weight. No UUID is adopted; retain this specific physical/chemical identity and confirm actual supply/used state, chemistry, provider and exact unit chain before dataset finalization.
- Selected flow: Cork glass-sheet separator pad
- Flow property / unit: Mass / kg
- Amount rule: Use the single stored normalization result from section8; the linked protocol first retains undivided actual raw quantities and stock/attribution evidence.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg reference flow
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging - Sources:
jrc-glass-bref-2013;ilcd-attributional-2010
Package received attached to inbound supplies: Cork glass-sheet separator pad (pad_supplier_inbound)
One actual cork glass-sheet separator pad component; condition package received attached to inbound supplies. Whole supplied article includes actual composition, treatment/coating/adhesive if present and tare/moisture. Record direction-specific unnormalized physical movement and history; keep opening/closing empty, attached WIP/FG and reusable states separately. Internal reuse cancels, not another purchase. Real repair needs separate new component input and removed old component/waste/vector, no guessed crate weight. No UUID is adopted; retain this specific physical/chemical identity and confirm actual supply/used state, chemistry, provider and exact unit chain before dataset finalization.
- Selected flow: Cork glass-sheet separator pad
- Flow property / unit: Mass / kg
- Amount rule: Use the single stored normalization result from section8; the linked protocol first retains undivided actual raw quantities and stock/attribution evidence.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg reference flow
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging - Sources:
jrc-glass-bref-2013;ilcd-attributional-2010
External package return received: Cork glass-sheet separator pad (pad_return_received)
One actual cork glass-sheet separator pad component; condition external package return received. Whole supplied article includes actual composition, treatment/coating/adhesive if present and tare/moisture. Record direction-specific unnormalized physical movement and history; keep opening/closing empty, attached WIP/FG and reusable states separately. Internal reuse cancels, not another purchase. Real repair needs separate new component input and removed old component/waste/vector, no guessed crate weight. No UUID is adopted; retain this specific physical/chemical identity and confirm actual supply/used state, chemistry, provider and exact unit chain before dataset finalization.
- Selected flow: Cork glass-sheet separator pad
- Flow property / unit: Mass / kg
- Amount rule: Use the single stored normalization result from section8; the linked protocol first retains undivided actual raw quantities and stock/attribution evidence.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg reference flow
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging - Sources:
jrc-glass-bref-2013;ilcd-attributional-2010
New package purchase: Steel glass-shipping strap (strap_purchase)
One actual steel glass-shipping strap component; condition new package purchase. Whole supplied article includes actual composition, treatment/coating/adhesive if present and tare/moisture. Record direction-specific unnormalized physical movement and history; keep opening/closing empty, attached WIP/FG and reusable states separately. Internal reuse cancels, not another purchase. Real repair needs separate new component input and removed old component/waste/vector, no guessed crate weight. No UUID is adopted; retain this specific physical/chemical identity and confirm actual supply/used state, chemistry, provider and exact unit chain before dataset finalization.
- Selected flow: Steel glass-shipping strap
- Flow property / unit: Mass / kg
- Amount rule: Use the single stored normalization result from section8; the linked protocol first retains undivided actual raw quantities and stock/attribution evidence.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg reference flow
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging - Sources:
jrc-glass-bref-2013;ilcd-attributional-2010
Package received attached to inbound supplies: Steel glass-shipping strap (strap_supplier_inbound)
One actual steel glass-shipping strap component; condition package received attached to inbound supplies. Whole supplied article includes actual composition, treatment/coating/adhesive if present and tare/moisture. Record direction-specific unnormalized physical movement and history; keep opening/closing empty, attached WIP/FG and reusable states separately. Internal reuse cancels, not another purchase. Real repair needs separate new component input and removed old component/waste/vector, no guessed crate weight. No UUID is adopted; retain this specific physical/chemical identity and confirm actual supply/used state, chemistry, provider and exact unit chain before dataset finalization.
- Selected flow: Steel glass-shipping strap
- Flow property / unit: Mass / kg
- Amount rule: Use the single stored normalization result from section8; the linked protocol first retains undivided actual raw quantities and stock/attribution evidence.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg reference flow
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging - Sources:
jrc-glass-bref-2013;ilcd-attributional-2010
External package return received: Steel glass-shipping strap (strap_return_received)
One actual steel glass-shipping strap component; condition external package return received. Whole supplied article includes actual composition, treatment/coating/adhesive if present and tare/moisture. Record direction-specific unnormalized physical movement and history; keep opening/closing empty, attached WIP/FG and reusable states separately. Internal reuse cancels, not another purchase. Real repair needs separate new component input and removed old component/waste/vector, no guessed crate weight. No UUID is adopted; retain this specific physical/chemical identity and confirm actual supply/used state, chemistry, provider and exact unit chain before dataset finalization.
- Selected flow: Steel glass-shipping strap
- Flow property / unit: Mass / kg
- Amount rule: Use the single stored normalization result from section8; the linked protocol first retains undivided actual raw quantities and stock/attribution evidence.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg reference flow
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging - Sources:
jrc-glass-bref-2013;ilcd-attributional-2010
Sawn wood crate-repair board (repair_wood_board_in)
Only when this actual distinct repair component crosses the boundary; measure its own composition/treatment/moisture and actual new or removed old mass plus inherited vector. Transfer incorporated part mass/vector to the repaired whole crate without another crate purchase; retain unrepaired residue and real losses. Additional actual adhesives, fasteners or parts need their own cards, never a repair total. No UUID is adopted; retain this specific physical/chemical identity and confirm actual supply/used state, chemistry, provider and exact unit chain before dataset finalization.
- Selected flow: Sawn wood crate-repair board
- Flow property / unit: Mass / kg
- Amount rule: Use the single stored normalization result from section8; the linked protocol first retains undivided actual raw quantities and stock/attribution evidence.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg reference flow
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging - Sources:
jrc-glass-bref-2013
Carbon-steel crate-repair nail (repair_steel_nail_in)
Only when this actual distinct repair component crosses the boundary; measure its own composition/treatment/moisture and actual new or removed old mass plus inherited vector. Transfer incorporated part mass/vector to the repaired whole crate without another crate purchase; retain unrepaired residue and real losses. Additional actual adhesives, fasteners or parts need their own cards, never a repair total. No UUID is adopted; retain this specific physical/chemical identity and confirm actual supply/used state, chemistry, provider and exact unit chain before dataset finalization.
- Selected flow: Carbon-steel crate-repair nail
- Flow property / unit: Mass / kg
- Amount rule: Use the single stored normalization result from section8; the linked protocol first retains undivided actual raw quantities and stock/attribution evidence.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg reference flow
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging - Sources:
jrc-glass-bref-2013
Elementary flows
Atmospheric water taken up by wood or cork packaging (package_moisture_in)
Actual independently measured water exchange with air, tagged to each physical package component and moisture state. Add this actual water direction explicitly to the component wet-mass closure alongside repair incorporation/removal; dry article and water child ledgers remain distinct. Do not infer water from an unclosed wood balance or treat it as product Q. No UUID is adopted; retain this specific physical/chemical identity and confirm actual supply/used state, chemistry, provider and exact unit chain before dataset finalization.
- Selected flow: Atmospheric water taken up by wood or cork packaging
- Flow property / unit: Mass / kg
- Amount rule: Use the single stored normalization result from section8; the linked protocol first retains undivided actual raw quantities and stock/attribution evidence.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg reference flow
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging - Sources:
jrc-glass-bref-2013
Outputs
Product flows
Package leaving with gross physical shipment: Wooden glass-sheet shipping crate (crate_gross_out)
One actual wooden glass-sheet shipping crate component; condition package leaving with gross physical shipment. Whole supplied article includes actual composition, treatment/coating/adhesive if present and tare/moisture. Record direction-specific unnormalized physical movement and history; keep opening/closing empty, attached WIP/FG and reusable states separately. Internal reuse cancels, not another purchase. Real repair needs separate new component input and removed old component/waste/vector, no guessed crate weight. No UUID is adopted; retain this specific physical/chemical identity and confirm actual supply/used state, chemistry, provider and exact unit chain before dataset finalization.
- Selected flow: Wooden glass-sheet shipping crate
- Flow property / unit: Mass / kg
- Amount rule: Use the single stored normalization result from section8; the linked protocol first retains undivided actual raw quantities and stock/attribution evidence.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg reference flow
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging - Sources:
jrc-glass-bref-2013;ilcd-attributional-2010
Package returned outward to external owner: Wooden glass-sheet shipping crate (crate_return_out)
One actual wooden glass-sheet shipping crate component; condition package returned outward to external owner. Whole supplied article includes actual composition, treatment/coating/adhesive if present and tare/moisture. Record direction-specific unnormalized physical movement and history; keep opening/closing empty, attached WIP/FG and reusable states separately. Internal reuse cancels, not another purchase. Real repair needs separate new component input and removed old component/waste/vector, no guessed crate weight. No UUID is adopted; retain this specific physical/chemical identity and confirm actual supply/used state, chemistry, provider and exact unit chain before dataset finalization.
- Selected flow: Wooden glass-sheet shipping crate
- Flow property / unit: Mass / kg
- Amount rule: Use the single stored normalization result from section8; the linked protocol first retains undivided actual raw quantities and stock/attribution evidence.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg reference flow
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging - Sources:
jrc-glass-bref-2013;ilcd-attributional-2010
Package leaving with gross physical shipment: Cork glass-sheet separator pad (pad_gross_out)
One actual cork glass-sheet separator pad component; condition package leaving with gross physical shipment. Whole supplied article includes actual composition, treatment/coating/adhesive if present and tare/moisture. Record direction-specific unnormalized physical movement and history; keep opening/closing empty, attached WIP/FG and reusable states separately. Internal reuse cancels, not another purchase. Real repair needs separate new component input and removed old component/waste/vector, no guessed crate weight. No UUID is adopted; retain this specific physical/chemical identity and confirm actual supply/used state, chemistry, provider and exact unit chain before dataset finalization.
- Selected flow: Cork glass-sheet separator pad
- Flow property / unit: Mass / kg
- Amount rule: Use the single stored normalization result from section8; the linked protocol first retains undivided actual raw quantities and stock/attribution evidence.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg reference flow
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging - Sources:
jrc-glass-bref-2013;ilcd-attributional-2010
Package returned outward to external owner: Cork glass-sheet separator pad (pad_return_out)
One actual cork glass-sheet separator pad component; condition package returned outward to external owner. Whole supplied article includes actual composition, treatment/coating/adhesive if present and tare/moisture. Record direction-specific unnormalized physical movement and history; keep opening/closing empty, attached WIP/FG and reusable states separately. Internal reuse cancels, not another purchase. Real repair needs separate new component input and removed old component/waste/vector, no guessed crate weight. No UUID is adopted; retain this specific physical/chemical identity and confirm actual supply/used state, chemistry, provider and exact unit chain before dataset finalization.
- Selected flow: Cork glass-sheet separator pad
- Flow property / unit: Mass / kg
- Amount rule: Use the single stored normalization result from section8; the linked protocol first retains undivided actual raw quantities and stock/attribution evidence.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg reference flow
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging - Sources:
jrc-glass-bref-2013;ilcd-attributional-2010
Package leaving with gross physical shipment: Steel glass-shipping strap (strap_gross_out)
One actual steel glass-shipping strap component; condition package leaving with gross physical shipment. Whole supplied article includes actual composition, treatment/coating/adhesive if present and tare/moisture. Record direction-specific unnormalized physical movement and history; keep opening/closing empty, attached WIP/FG and reusable states separately. Internal reuse cancels, not another purchase. Real repair needs separate new component input and removed old component/waste/vector, no guessed crate weight. No UUID is adopted; retain this specific physical/chemical identity and confirm actual supply/used state, chemistry, provider and exact unit chain before dataset finalization.
- Selected flow: Steel glass-shipping strap
- Flow property / unit: Mass / kg
- Amount rule: Use the single stored normalization result from section8; the linked protocol first retains undivided actual raw quantities and stock/attribution evidence.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg reference flow
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging - Sources:
jrc-glass-bref-2013;ilcd-attributional-2010
Package returned outward to external owner: Steel glass-shipping strap (strap_return_out)
One actual steel glass-shipping strap component; condition package returned outward to external owner. Whole supplied article includes actual composition, treatment/coating/adhesive if present and tare/moisture. Record direction-specific unnormalized physical movement and history; keep opening/closing empty, attached WIP/FG and reusable states separately. Internal reuse cancels, not another purchase. Real repair needs separate new component input and removed old component/waste/vector, no guessed crate weight. No UUID is adopted; retain this specific physical/chemical identity and confirm actual supply/used state, chemistry, provider and exact unit chain before dataset finalization.
- Selected flow: Steel glass-shipping strap
- Flow property / unit: Mass / kg
- Amount rule: Use the single stored normalization result from section8; the linked protocol first retains undivided actual raw quantities and stock/attribution evidence.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg reference flow
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging - Sources:
jrc-glass-bref-2013;ilcd-attributional-2010
Waste flows
Package component transferred as waste: Wooden glass-sheet shipping crate (crate_waste)
One actual wooden glass-sheet shipping crate component; condition package component transferred as waste. Whole supplied article includes actual composition, treatment/coating/adhesive if present and tare/moisture. Record direction-specific unnormalized physical movement and history; keep opening/closing empty, attached WIP/FG and reusable states separately. Internal reuse cancels, not another purchase. Real repair needs separate new component input and removed old component/waste/vector, no guessed crate weight. No UUID is adopted; retain this specific physical/chemical identity and confirm actual supply/used state, chemistry, provider and exact unit chain before dataset finalization.
- Selected flow: Wooden glass-sheet shipping crate
- Flow property / unit: Mass / kg
- Amount rule: Use the single stored normalization result from section8; the linked protocol first retains undivided actual raw quantities and stock/attribution evidence.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg reference flow
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging - Sources:
jrc-glass-bref-2013;ilcd-attributional-2010
Package component transferred as waste: Cork glass-sheet separator pad (pad_waste)
One actual cork glass-sheet separator pad component; condition package component transferred as waste. Whole supplied article includes actual composition, treatment/coating/adhesive if present and tare/moisture. Record direction-specific unnormalized physical movement and history; keep opening/closing empty, attached WIP/FG and reusable states separately. Internal reuse cancels, not another purchase. Real repair needs separate new component input and removed old component/waste/vector, no guessed crate weight. No UUID is adopted; retain this specific physical/chemical identity and confirm actual supply/used state, chemistry, provider and exact unit chain before dataset finalization.
- Selected flow: Cork glass-sheet separator pad
- Flow property / unit: Mass / kg
- Amount rule: Use the single stored normalization result from section8; the linked protocol first retains undivided actual raw quantities and stock/attribution evidence.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg reference flow
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging - Sources:
jrc-glass-bref-2013;ilcd-attributional-2010
Package component transferred as waste: Steel glass-shipping strap (strap_waste)
One actual steel glass-shipping strap component; condition package component transferred as waste. Whole supplied article includes actual composition, treatment/coating/adhesive if present and tare/moisture. Record direction-specific unnormalized physical movement and history; keep opening/closing empty, attached WIP/FG and reusable states separately. Internal reuse cancels, not another purchase. Real repair needs separate new component input and removed old component/waste/vector, no guessed crate weight. No UUID is adopted; retain this specific physical/chemical identity and confirm actual supply/used state, chemistry, provider and exact unit chain before dataset finalization.
- Selected flow: Steel glass-shipping strap
- Flow property / unit: Mass / kg
- Amount rule: Use the single stored normalization result from section8; the linked protocol first retains undivided actual raw quantities and stock/attribution evidence.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg reference flow
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging - Sources:
jrc-glass-bref-2013;ilcd-attributional-2010
Removed wood crate-repair board waste (repair_wood_board_out)
Only when this actual distinct repair component crosses the boundary; measure its own composition/treatment/moisture and actual new or removed old mass plus inherited vector. Transfer incorporated part mass/vector to the repaired whole crate without another crate purchase; retain unrepaired residue and real losses. Additional actual adhesives, fasteners or parts need their own cards, never a repair total. No UUID is adopted; retain this specific physical/chemical identity and confirm actual supply/used state, chemistry, provider and exact unit chain before dataset finalization.
- Selected flow: Removed wood crate-repair board waste
- Flow property / unit: Mass / kg
- Amount rule: Use the single stored normalization result from section8; the linked protocol first retains undivided actual raw quantities and stock/attribution evidence.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg reference flow
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging - Sources:
jrc-glass-bref-2013
Removed carbon-steel crate nail waste (repair_steel_nail_out)
Only when this actual distinct repair component crosses the boundary; measure its own composition/treatment/moisture and actual new or removed old mass plus inherited vector. Transfer incorporated part mass/vector to the repaired whole crate without another crate purchase; retain unrepaired residue and real losses. Additional actual adhesives, fasteners or parts need their own cards, never a repair total. No UUID is adopted; retain this specific physical/chemical identity and confirm actual supply/used state, chemistry, provider and exact unit chain before dataset finalization.
- Selected flow: Removed carbon-steel crate nail waste
- Flow property / unit: Mass / kg
- Amount rule: Use the single stored normalization result from section8; the linked protocol first retains undivided actual raw quantities and stock/attribution evidence.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg reference flow
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging - Sources:
jrc-glass-bref-2013
Elementary flows
Water evaporated from wood or cork packaging to air (package_moisture_out)
Actual independently measured water exchange with air, tagged to each physical package component and moisture state. Add this actual water direction explicitly to the component wet-mass closure alongside repair incorporation/removal; dry article and water child ledgers remain distinct. Do not infer water from an unclosed wood balance or treat it as product Q. No UUID is adopted; retain this specific physical/chemical identity and confirm actual supply/used state, chemistry, provider and exact unit chain before dataset finalization.
- Selected flow: Water evaporated from wood or cork packaging to air
- Flow property / unit: Mass / kg
- Amount rule: Use the single stored normalization result from section8; the linked protocol first retains undivided actual raw quantities and stock/attribution evidence.
- Value mode: Calculated value (
calculated_value) - Specificity: Site-specific (
site_specific) - Normalization basis: per 1 kg reference flow
- Basis kind: Reference flow (
reference_flow) - Evidence kind: Calculated from collection (
calculated_from_collection) - Collection protocol:
cp_packaging - Sources:
jrc-glass-bref-2013
7. Allocation and Co-product Handling
| rule_id | Applies to | Rule | source_ids |
|---|---|---|---|
| a_dedicated | all inventory rows | This is attributional modelling. First identify dedicated operations and actual measured exchange-specific attribution. Subdivide physically or by evidenced virtual subdivision of shared furnace/forehearth, forming, abatement and services where independent data permit. Distinguish rolled line from a co-fed float line at the molten-glass gate; the manufacturer shared-furnace example supplies no allocation factor. | ilcd-attributional-2010; pilkington-rolled-line-2025 |
| a_causal | all inventory rows | For genuinely remaining shared exchanges use a determining physical causal relation supported by actual process response at the same states; energy may require melt composition/temperature/enthalpy and residence/quality duties, not mass alone. Record scope and data for each exchange and verify sums. Mass, area, nominal thickness, recipe share or revenue is not an automatic physical allocation rule. | ilcd-attributional-2010; jrc-glass-bref-2013 |
| a_residual | all inventory rows | Only if subdivision and determining physical causality cannot resolve the genuine common-process residual, identify actual joint products at one common exit gate/state and use contemporaneous representative actual market values for that residual with sensitivity and evidence. No arbitrary choice between physical and economic bases, no fixed percentage and no automatic substitution credit. Waste classification follows actual holder/specification/treatment; a sale does not by itself establish a coproduct. | ilcd-attributional-2010 |
| a_internal | all inventory rows | Internal cullet, batch dust returned under compatibility control, hot glass transfer and product-to-service transfers are internal; cancel them on consolidation without avoided virgin-material credit or duplicate purchase. Carry each exchange vector through recovery, WIP and original-cohort return, retaining real incremental reprocessing energy/emissions and losses. Separate external pre-consumer and post-consumer cullet; inherited upstream burden/cutoff convention must be documented, never inferred from internal recycling. | ilcd-attributional-2010; jrc-glass-bref-2013 |
| asset_manufacture_conservation | existing capital/reusable manufacture attribution | Within the applicable allocation decision context, original manufacture burden attributed across uses of actual capital equipment or reusable articles already included in foreground production, packaging or observed services uses one persistent same-asset ledger across all crops, products, cohorts, manufacturing/postrelease services, owners and observation periods. D is its supported whole installed service: all realized historical service plus supported remaining service in the same units as actual beneficiary use u; D must be finite and positive. Period capacity, remaining-only capacity, the physical asset/article mass alone, or current-period product Q alone is not D; supported whole-service throughput in mass units may be used when it demonstrates the causal service and matches u. This does not amortize the manufactured reference product over downstream life or change its declared reference gate/Q. The fractions u/D and all previously assigned manufacture shares together must never exceed 1. Changes of window, custody, provider or repair never restart the original manufacture balance. Replacements have distinct identities and only their real new manufacture vectors; actual repair and treatment increments remain separately accounted. Revised capacity evidence requires transparent reconciliation of prior shares and sensitivity, not a fresh ledger. Keep full physical mass and stock movements independent of burden shares. Unknown D, prior shares or beneficiary coverage requires review and no final manufacture-attributed amount; no assumed lifetime, utilization, zero or arbitrary division is permitted. For each existing collection protocol that attributes manufacture of included production, packaging or observed-service assets across uses in this route (excluding amortization of the manufactured reference product itself), additionally retain a durable asset identity, its measured full physical mass and acquisition/installation/retirement stock history, original manufacture burden vector, all historical and current beneficiaries, matched-unit service readings, the evidenced whole installed-service denominator D, supported remaining-service basis and uncertainty, prior assigned shares and remaining original manufacture balance. Carry the ledger across reporting windows and custody/provider changes. Collect actual repair, replacement, recovery and treatment separately; these records do not normalize physical movements or create an additional asset purchase. These are added fields and conservation obligations for the existing applicable protocols, not a new assumed capital inventory. |
8. Foreground Data Collection, Calculation, and Quality Rules
Data Collection Protocols
For each existing collection protocol that attributes manufacture of included production, packaging or observed-service assets across uses in this route (excluding amortization of the manufactured reference product itself), additionally retain a durable asset identity, its measured full physical mass and acquisition/installation/retirement stock history, original manufacture burden vector, all historical and current beneficiaries, matched-unit service readings, the evidenced whole installed-service denominator D, supported remaining-service basis and uncertainty, prior assigned shares and remaining original manufacture balance. Carry the ledger across reporting windows and custody/provider changes. Collect actual repair, replacement, recovery and treatment separately; these records do not normalize physical movements or create an additional asset purchase. These are added fields and conservation obligations for the existing applicable protocols, not a new assumed capital inventory.
| protocol_id | process_id | flow_role | record_type | raw_fields | collection_method | unit | frequency | temporal_coverage | site_scope | aggregation_rule | quality_evidence |
|---|---|---|---|---|---|---|---|---|---|---|---|
| cp_batch | batch | Each separate ingredient batch and internal transfer | weighing and supplier records | exchange_id; lot; whole delivered mass; opening and closing raw stock; actual assay; free moisture; hydrate identity; cullet origin; preparation loss; electricity meter; cargo mass and route distance; counterpart transfer; inherited vector | Calibrated weighbridge/hopper net weighings, invoices and assay/moisture tests; record each whole preparation once; pair exact internal batch/cullet transfers and transport evidence. Record all failure, spill, cleanup and mixing energy, not only successful batches. All raw fields remain undivided actual records; aggregation only reads the same stored section8 result without another division by Q. | kg; kWh; t*km | each lot and metered interval | complete matched manufacture and stock boundary | actual suppliers and batch/cullet site | per 1 kg reference flow | Calibration traceability; original readings and invoices; actual state/assay/test evidence; exact stock and counterpart reconciliation; uncertainty and missing coverage disclosed |
| cp_manufacture | manufacture | Each manufacturing material utility and non-WIP asset | meters stocks maintenance and mass balance | exchange_id; furnace cohort; original meter unit and readings; timestamps; true rate flag; gas composition density pressure temperature LHV; cooling inlet and outlet state; ingredient/utility water; oil charge; molten heel WIP; asset installation replacement wear and remaining life; allocation evidence; stock physical mass and per-exchange vectors; every exit receiver; actual_air_N2_O2_Ar_atmospheric_CO2_gaseous_H2O_inlets_and_gross_outlets; gas_T_P_wet_dry_basis; nonadditive_gas_totals_and_CO2_H2O_source_partitions; actual_reaction_absorption_phase_receiver | Use calibrated meters and direct weighing, thermodynamic state measurements, maintenance asset and loop-stock surveys, actual recipe/lot reconciliation and separate exit manifests. Retain failed/startstop/hot hold/idle/cleanup/changeover intervals and measured shared-furnace attribution; no assumed efficiencies or lifetimes. All raw fields remain undivided actual records; aggregation only reads the same stored section8 result without another division by Q. Independently measure each air-species inlet/outlet and humidity/state; no fixed recipe or one-residual fitting of multiple species/water. Whole gas, CO2/H2O source fractions and net increment are non-additive observations, not more environmental flows. Resource and Emission identities match their own actual compartments; every actual other phase needs an atomic row before data use. | kg; kWh; m3; MJ; K; Pa | each interval batch and maintenance event | entire matched furnace campaign with stock boundaries | actual furnace forehearth roller lehr utilities and abatement | per 1 kg reference flow | Calibration traceability; original readings and invoices; actual state/assay/test evidence; exact stock and counterpart reconciliation; uncertainty and missing coverage disclosed |
| cp_release | manufacture | Unique first-quality-release net mass Q | calibrated weighing and quality records | cohort_id; sheet_id; new first-release event; calibrated gross tare and net kg; sheet count; accepted area; profile and independent density if converting area; surface moisture; pattern orientation; residual stress dimensional optical and defect acceptance; actual state and time; reinspection original cohort | Weigh accepted bare annealed unworked stock sheets on calibrated scales excluding packaging and free wash water; reconcile release register and unique IDs with actual count/area and acceptance tests. Declare weighing moisture/temperature. Any area conversion uses measured profile volume and independently measured actual density, never borrowed flat nominal thickness. All raw fields remain undivided actual records; aggregation only reads the same stored section8 result without another division by Q. | kg; m2; count | each first release and rejection | one matched manufacturing cohort through first release | actual inspection cutting and release gate | per 1 kg reference flow | Calibration traceability; original readings and invoices; actual state/assay/test evidence; exact stock and counterpart reconciliation; uncertainty and missing coverage disclosed |
| cp_emissions | manufacture | Each actual emitted species and phase destination | analytical monitoring and independent balances | exchange_id; actual CAS and species; source origin; compartment; sampling time; dry or wet concentration; analytical molecular basis; actual flue rate or integrated volume; oxygen normalization; pressure temperature moisture; abatement; blank detection uncertainty; fuel and carbonate carbon; free hydrate reaction water; mass and element balances; actual_air_N2_O2_Ar_atmospheric_CO2_gaseous_H2O_inlets_and_gross_outlets; gas_T_P_wet_dry_basis; nonadditive_gas_totals_and_CO2_H2O_source_partitions; actual_reaction_absorption_phase_receiver | Use actual site species-specific sampling and validated chemistry/assay balance; convert same-state concentration times integrated gas volume, or integrate concentration times true flow rate. Resolve NO/NO2 rather than treating NOx-equivalent as both. Physically and chemically distinguish dust species, water phases and all exits; preserve unknown species as incomplete and add actual cards. All raw fields remain undivided actual records; aggregation only reads the same stored section8 result without another division by Q. Independently measure each air-species inlet/outlet and humidity/state; no fixed recipe or one-residual fitting of multiple species/water. Whole gas, CO2/H2O source fractions and net increment are non-additive observations, not more environmental flows. Resource and Emission identities match their own actual compartments; every actual other phase needs an atomic row before data use. | kg; original analytical unit; m3; time | actual monitored and production intervals including nonproduction loads | complete matched manufacture including startstop and abatement | actual stack fugitive cooling and abatement exits | per 1 kg reference flow | Calibration traceability; original readings and invoices; actual state/assay/test evidence; exact stock and counterpart reconciliation; uncertainty and missing coverage disclosed |
| cp_services | services | Each original-cohort FG movement and actual service increment | custody movement meter and damage records | original_cohort_id; original Q; original delivery_id; opening and closing FG kg moisture and inherited vectors; new first-release transfer; gross dispatch; external return in and outward return; service damage; actual repair and recut new old masses; measured moisture uptake/loss; electricity and package records; service observation closing date | Reconcile original release and dispatch/return documents, weigh physical gross movements and FG stocks at actual moisture, meter incremental services and pair damage/recovery receipts. Preserve historical manufacturing vector; reverse only actual original delivery view, never generate new production for old returned sheets. All raw fields remain undivided actual records; aggregation only reads the same stored section8 result without another division by Q. | kg; kWh | each custody event and metered service interval | actual disclosed service interval per original release cohort | actual FG warehouse packing handling and dispatch locations | per 1 kg reference flow | Calibration traceability; original readings and invoices; actual state/assay/test evidence; exact stock and counterpart reconciliation; uncertainty and missing coverage disclosed |
| cp_packaging | packaging | Each individual package component and direction | component stock tare purchase return shipment waste and repair records | component_id; cohort_id; whole formulation tare and moisture; opening empty attached_WIP attached_FG and reusable states; new purchase; supplier inbound attached receipt; external customer return received; all closing states; attached gross physical outward shipment; external return out; waste; internalreuse counterpart; repair new part old part loss; per-exchange inherited vector | Direct calibrated component tare weighing and moisture records plus all custody documents; balance each component independently under b_packages. An attached package is not bought again when reused; actual repair records retain both new material input and old removed part/output and vector. All raw fields remain undivided actual records; aggregation only reads the same stored section8 result without another division by Q. | kg | each physical movement stock count and repair event | matched cohort full service period and opening closing stock states | actual suppliers site customers and return receivers | per 1 kg reference flow | Calibration traceability; original readings and invoices; actual state/assay/test evidence; exact stock and counterpart reconciliation; uncertainty and missing coverage disclosed |
Calculation Rules
| rule_id | Applies to | Formula or rule | Inputs | Output | source_ids |
|---|---|---|---|---|---|
| normalize_once | all inventory rows | For Q_c > 0 store result_j_c = A_j_c / Q_c exactly once. Construct raw A_j_c only after original-unit/rate/state conversion and genuine exchange-specific attribution. Manufacturing burden A uses opening inherited raw/WIP/heel/utility/asset vectors plus attributable current use minus disjoint eligible retained closing vectors and only documented burden portions transferred to independent cohorts or genuine joint products. Establish transfer/allocation eligibility under section7 first and transfer each vector once; a physical exit alone is not a burden deduction. Ordinary manufacturing glass waste, filter dust, disposal, failed batches, samples/quality losses and their associated treatment burdens remain with the original manufacturing cohort and are never automatically deducted as traced exits. Declare raw material records as receipts, actual issues/returns or already stock-corrected use; do not repeat the same stock correction on corrected current use. Closing released FG is already in Q and retains its full manufacturing burden, never another subtraction. Original-cohort service A is real incremental burden plus opening minus closing service-WIP/charge vectors, with historical production carried once. Physical movement cards retain their actual undivided movement as the numerator; burden consumption and custody are distinct linked views and are not summed as duplicate LCI. Cancel internal counterparts; cards/protocol aggregation read only this stored result. At Q_c=0 retain actual loads and produce no unit value. | A_j_c; Q_c; cohort_id; original_delivery_id | result_j_c | jrc-glass-bref-2013; ilcd-attributional-2010 |
| raw_state_conversion | all inventory rows | Before normalize_once, convert original readings with their actual factor and uncertainty. Sum actual mass/energy/transport. Multiply concentration by same-state cumulative volume once; only a true rate is integrated over elapsed time. Gas/liquid volume to mass uses independently measured substance density at the actual pressure/temperature/composition; carried water remains a subaccount. Match inlet/outlet enthalpy for actual external water returns, without inventing steam. | original_reading; actual_state; independent_conversion_factor; timestamp | raw_converted_quantity | jrc-glass-bref-2013 |
| stock_vector_closure | all inventory rows | Before normalize_once, close each physical substance/article and each independent exchange-vector component at manufacture, services and consolidated gates. Pair raw/batch/cullet/FG transfers and cancel identical internal quantities/vectors. Retain independent non-WIP loops/charges/assets and opening/closing WIP/heel. For packaging use the full b_packages equation per component, including all attached states, inbound receipt, customer return and repair old/new masses. One residual cannot determine two unknowns. | opening_stock; current_inputs; physical_outputs; closing_stock; inherited_exchange_vector | reconciled_raw_numerator | jrc-glass-bref-2013; ilcd-attributional-2010 |
| asset_manufacture_share | existing capital/reusable manufacture attribution | For each included original asset manufacture vector B, f_current = u_current / D only after the persistent ledger verifies the supported whole installed-service denominator, all beneficiaries and prior assigned shares. Attribute f_current * B once to the actual beneficiary before the existing single reference normalization. Check prior_shares + all current/new beneficiary shares <= 1; carry the remaining original balance. Capacity revisions reconcile the historical ledger. Full physical asset/packaging mass and actual gross stocks/returns never receive f_current. Unknown D or history leaves the final attributed result unavailable, without suppressing actual repair/replacement/service burdens. | asset_id; original_B; u_current; D; historical_beneficiaries; prior_shares; capacity_evidence | conserved attributed manufacture vector |
Data Quality Requirements
| requirement_id | Applies to | Requirement | Evidence |
|---|---|---|---|
| dq_identity | all inventory rows | Demonstrate actual product pattern/composition/route/state and whole supplied chemistry/provider compatibility; retain per-card UUID restrictions and official Chinese basenames. Candidate query membership alone is insufficient. | Specifications; actual native records; supplier assays; exact property/unit chain |
| dq_quantity | all inventory rows | All future actual quantities, densities, chemical speciation, life/throughput and allocation relations require retained measurement evidence and uncertainties; this PCR invents none. Unsupported or missing values are explicit gaps, not a zero or a pass. | Calibration traceability; original readings and invoices; actual state/assay/test evidence; exact stock and counterpart reconciliation; uncertainty and missing coverage disclosed |
| dq_completeness | all inventory rows | Retain full failed/nonproductive and service coverage, stock and inheritance closures, all actual new atomic flows, package directions and species; separate measured checks from unmeasured scope. | Original logs; reconciliation worksheets; analytical records; coverage and limitations |
| dq_source | all inventory rows | JRC2013 manufacturing context and publisher product evidence are complementary qualitative sources; no single common recipe/factory or transferable numerical factors. ILCD supports attributional allocation only, not industrial chemistry. | Source-specific applicability and contrary-context review; foreground supplier/plant evidence |
9. Validation Rules
| rule_id | Applies to | Rule | source_ids |
|---|---|---|---|
| v_scope | all inventory rows | Verify full section1 route and every qualifier; reject a tin-bath, ground/polished, strengthened, wired, coated or downstream-assembled product as this reference. Pattern acceptance is configuration-specific, not certification inferred from kg or nominal thickness. | jrc-glass-bref-2013; pilkington-texture; pilkington-strength-2025 |
| v_q | finished | Reconcile calibrated net accepted weighings and unique first-release events to Q; counts and areas are supporting records. Already-released closing FG, old stock and returned/retested pieces create no extra Q. Q=0 retains actual burdens and produces no unit result. | jrc-glass-bref-2013; pilkington-texture |
| v_balance | all inventory rows | Check independent physical and element closures plus species evidence, full WIP/heel/FG and non-WIP utility/asset vectors, every real gas/liquid destination, separate batch/fuel carbon and free/structural/reaction water. Unknown measurements or unresolved closures are explicit incomplete findings; do not force them to pass. | jrc-glass-bref-2013 |
| v_normalize | all inventory rows | Confirm raw original-unit records are undivided; unit/rate/state conversion, stock inheritance and genuine allocation precede the single section8 normalization. Cards and collection aggregation consume its stored result only. Check all manufacturing/service/consolidated gates and internal cancellations on the same basis. | jrc-glass-bref-2013; ilcd-attributional-2010 |
| v_packages | packaging | Independently close each package component across empty/attached/reusable stocks, new and inbound receipts, customer returns, gross outward shipments, external returns and waste; reconcile moisture and old/new repaired parts/vectors. No internal reuse appears as new input or product Q. | jrc-glass-bref-2013; ilcd-attributional-2010 |
| v_identity | all inventory rows | Before a concrete dataset is final, match each adopted UUID against all native names/synonyms/comments/CAS, grade, route, form, geography, type, compartment and every property with its exact property→unit-group→reference-unit chain. Generic identities establish no supplier, specification, performance or quantity. Preserve per-card restrictions; unresolved atomic names need matching, not an omitted exchange. | jrc-glass-bref-2013 |
| v_sources | all inventory rows | Disclose source applicability, age, route/state differences and technical synthesis separately from actual foreground measurements. Do not use BREF clear-float normal-operation ranges, nominal catalogue dimensions, strength percentages or the shared-furnace marketing saving as generic factors. Engineering checks do not establish scientific, translation, mapping or publication approval. | jrc-glass-bref-2013; pilkington-rolled-line-2025; pilkington-strength-2025 |
| validate_asset_manufacture_conservation | existing capital/reusable manufacture attribution | For every included capital/reusable manufacture attribution verify same-asset continuity, whole installed service in matched units, all historical/current beneficiaries, prior assigned manufacture shares and cumulative share <= 1. Reject a reset by period, cohort, provider, owner or repair. Check distinct real replacement and incremental repair/treatment vectors separately and preserve gross physical mass. A missing denominator, unexplained previous allocation or incomplete beneficiary ledger requires explicit review and an unavailable final attributed amount; structural inspection cannot claim empirical completeness. |
10. Published Dataset Profile
| Field | Value |
|---|---|
| dataset_role | secondary_dataset |
| downstream_use | background_dataset for the exact declared unworked sheet as input to later separately modelled glass processing |
| allowed_use | Attributional cradle-to-first-release manufacturing with separately disclosed observed original-cohort services; only compatible pattern/composition/route/state |
| excluded_use | Exclude float/tin-bath forming; ground or polished faces; drawn or blown sheets; table casting; wired glass; body-tinted, opacified or borosilicate compositions; dedicated photovoltaic cover products; tempering or heat strengthening; laminating; coating including online coating or SO2 surface treatment; mirrors; insulating glazing assemblies; drilling, edge polishing or fabrication beyond unworked stock-sheet cutting; installation/use/end of life. A real changed route requires renewed applicability and all actual atomic exchanges, never an assumed zero. A pattern embossed into hot glass is not an added coating. Unworked annealed sheets establish no safety-glazing rating. [jrc-glass-bref-2013; pilkington-texture; un-cpc3-2025] |
| required_metadata | All reference qualifiers; actual supplier/site/period; source and raw protocol references; Q; gate; campaign and service closing date; disjoint manufacturing/service/custody views; actual allocation |
| required_quality_disclosure | Uncertainty and measurement coverage; source technical synthesis; all unresolved identities/quantities; stock/vector/species closures; no scientific or certification approval inferred |
| update_trigger | Changed composition cullet quality pattern roller route furnace share energy system gate provider specification or material evidence |
11. Data Sources
| Source id | Type | Reference | Used for |
|---|---|---|---|
| jrc-glass-bref-2013 | official_guidance | European Commission JRC, BAT Reference Document for the Manufacture of Glass (2013), EUR25786EN, doi:10.2791/69502; https://bureau-industrial-transformation.jrc.ec.europa.eu/sites/default/files/2019-11/GLS_Adopted_03_2012_0.pdf | Sections2.2,2.5,2.5.2 and3.2/3.4: raw batch, melting chemistry, water-cooled rollers, annealing, utilities, losses and actual emissions/destinations; adjacent float/wired/fibre and old clear-float survey limitations; qualitative only |
| pilkington-texture | literature | Pilkington, Pilkington Texture Glass, complete publisher product page, retained2026-10-20; https://www.pilkington.com/en/us/products/product-categories/decoration/pilkington-texture-glass | Real rolled patterned sheet endpoint and downstream toughened/laminated/IGU distinctions; nominal sizes/performance not transferred |
| pilkington-rolled-line-2025 | literature | Pilkington UK, Pilkington UK opens new glass production line in St Helens,30June2025; https://www.pilkington.com/en-gb/united-kingdom/news/articles/pilkington-uk-opens-new-glass-production-line-in-st-helens | Current rolled-line existence and shared melting-source counterexample; no carbon-saving factor or allocation rule |
| pilkington-product-guide-2017 | literature | Pilkington North America, Architectural Glass Product Guide,2017 publisher PDF pp26–27; https://www.pilkington.com/~/media/624A9636357741C49BEE4A3D2C76F02C.ashx | Continuous hot ribbon passed between two rollers with one patterned roll; actual pattern illustrations and adjacent product/performance exclusions only |
| pilkington-strength-2025 | literature | Pilkington North America, ATS158 Strength of Pilkington Texture Glass,April2025,complete pp1–2; https://www.pilkington.com/-/media/pilkington/site-content/usa/window-manufacturers/technical-bulletins/ats-158---strength-of-pilkington-texture-glass.pdf | Pattern stress-concentration and Warwick counterexample, application/warranty limits; prohibits thickness-only strength equivalence; no percentage adopted |
| ilcd-attributional-2010 | official_guidance | European Commission JRC, ILCD Handbook General guide for Life Cycle Assessment Detailed guidance, first edition March2010,§§7.9.2–7.9.3 pp255–268; https://eplca.jrc.ec.europa.eu/uploads/ILCD-Handbook-General-guide-for-LCA-DETAILED-GUIDANCE-12March2010-ISBN-fin-v1.0-EN.pdf | Attributional dedicated/subdivision and virtual subdivision, exchange-specific determining physical causality and genuine residual common-exit-state market value; no arbitrary ratio or substitution credit |
| un-cpc3-2025 | official_guidance | United Nations Statistics Division, CPC Version3.0 Explanatory Notes30June2025,37111–37116 and adjacent context; https://unstats.un.org/unsd/classifications/Econ/Download/In%20Text/CPC_Ver_3.0_Exp_Notes_30Jun2025.pdf | Classification scope context only: unworked cast/rolled/drawn/blown versus float/ground/polished and worked glass; no manufacturing method or mapping approval |
Raw downloads
These files are byte-identical to the canonical files for this revision in the repository.
Complete field inspector
Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.