TianGong PCR

Electric blankets

Lifecycle status
Candidate
Content maturity
Authored methodology
Current version
0.1.0Last updated
Readiness
Review required

Methodology and translation states come from the source record; publishing this website does not change their review status.

Content languages

zh-CN · Aligned
Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:44813 · exact

Source

1. Scope and Applicability

This candidate governs foreground production of complete domestic electric textile overblankets and underblankets at the factory gate. Its reference is manufactured product mass, not an hour of warmth. Manufacture includes actual textile preparation, heater integration, controls, electrical connection, acceptance and dispatch. Consumer operation, laundering and end-of-life are separate downstream scenarios. Beurer supplies both underblankets and overblankets; its documented nonwoven blend and removable controls are examples, not a universal BOM. Independent patented constructions show insulated cable and integrated conductive yarn alternatives. [beurer-ub60; beurer-throws; woven-heater-patent; cable-heater-patent]

Passive blankets, standalone heater parts, heated clothing, seat heaters and medical thermal therapy devices require their own principal-function and classification review. A patent using “blanket” broadly for pads does not prove those products belong to this domestic boundary. Actual novelty, battery supply or an unusual heater design remains eligible for product review; it requires its own verified BOM, specific rows and supplier evidence rather than an unsupported method exclusion.

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.metal-products-machinery-and-equipment.special-purpose-machinery.electric-blankets
classification_refsCPC 3.0 44813 — Electric blankets
covered_productsComplete domestic electric textile overblanket; complete domestic electric textile underblanket
excluded_productsPassive blankets; separately supplied parts; medical therapy devices; heated garments and seats
representative_productDomestic blanket with actual textile heater, control and power connection
production_routePurchased textile and insulated-heater assembly; conditional on-site heater/yarn/textile manufacture; actual make/buy matrix
market_stateAccepted manufactured product at factory gate

3. Reference Flow

FieldValue
WhatAccepted complete domestic electric blanket of one declared configuration
How much1 kg net finished product
How wellMeets actual model-specific electrical, thermal protection, textile and acceptance requirements
How long or cycleOne factory production cohort; service life declared only in a separate use scenario
reference_flow_linkfinished_blanket
FieldValue
Reference amount1
Reference product flowElectric blankets db63276c-3e0f-4fe9-80de-b45ff12d515b
Reference flow propertyMass 93a60a56-a3c8-11da-a746-0800200b9a66
Reference unit groupUnits of mass 93a60a57-a4c8-11da-a746-0800200c9a66
Reference unitkg
Required qualifiersmodel; over/under form; dimensions; fibre blend/finish; heater construction and conductor/insulation chemistry; zones; supply voltage and plug/geography; controller/protection and sensing architecture; included cord/accessories; make/buy boundary; accepted net mass and cohort; site/period; test protocol

Declare every required qualifier in the foreground package. The generic reference flow supports manufactured electric-blanket identity and Mass; it supplies no geography, BOM, provider or empirical quantity. Missing qualifiers make the concrete package incomplete.

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
reference_massreference productMass 93a60a56-a3c8-11da-a746-0800200b9a66kgM = accepted net mass of one complete unit of the same configuration in kg; collect using cp_mass.
physical_basisphysical material and species recordsMasskgMeasure each actual material and each contained species on its own matched assay and wet/dry basis. Gross cable or fabric mass is not metal, polymer or solvent content. Convert length/count using actual batch mass or grade-specific measured linear/areal mass.
utility_basisutility recordsEnergykWhKeep delivered electricity units, voltage, supplier/site geography and time period; document kWh/MJ conversions. No source-specific waste-incineration electricity is a generic factory grid supply.

5. System Boundary

Boundary Abstraction

FieldValue
declared_starting_conditionActual purchased fabric/yarn, heater cable/yarn, control and connection subassemblies or documented raw-grade fabrication inputs
starting_condition_roleforeground_boundary_choice
product_classification_scopeDomestic electric textile blanket manufactured product
recursive_input_ruleA purchased unfinished/complete blanket entering further finishing is one upstream intermediate with documented included operations; do not recurse or duplicate its embedded inputs
upstream_dataset_requirementEach purchased exchange needs actual grade, geography, technology and delivered interface matching supplier evidence
disclosureSite, period, actual make/buy matrix, included accessories, upstream links, omitted operations and downstream scenario separation
rule_idapplies_torulesource_ids
b_makebuyall processesFor each textile layer, heater, controller and connection, choose complete purchased component or on-site fabrication. The former includes its embedded materials upstream once; the latter records every actual individual grade, chemical, utility, waste and release. Add distinct atomic rows for actual alternatives not listed here; examples are not compulsory recipes.
b_factoryall processesInclude transport into the declared factory boundary, actual conversion, joining, testing, rework, reject treatment and packaging; transport providers require separate mode-specific freight rows. Later space/body heating, laundering, product lifetime and disposal belong only to explicitly separate lifecycle scenarios.

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
textileTextile preparation and cutting/sewingconditionalActual operation or actual purchased interface; absent route documentedforegroundfinished_blanket
heaterHeater manufacture or purchased-heater integrationrequiredActual operation or actual purchased interface; absent route documentedforegroundfinished_blanket
assemblyControl, wiring and blanket assemblyrequiredActual operation or actual purchased interface; absent route documentedforegroundfinished_blanket
testAcceptance tests and reject handlingrequiredActual operation or actual purchased interface; absent route documentedforegroundfinished_blanket
dispatchPackaging and factory-gate dispatchrequiredActual operation or actual purchased interface; absent route documentedforegroundfinished_blanket
servicesResidual factory shared servicesconditionalActual operation or actual purchased interface; absent route documentedforegroundfinished_blanket

Rows below are conditional atomic interfaces. Record actual material grade and supplier, and distinguish not_applicable (verified absence), measured zero and unknown. Complete purchased assemblies replace, rather than accompany, embedded raw-material inputs. Extend the package for each actual resin, dye, adhesive formulation, flux, solder alloy, textile, fuel or species individually; unknown composition blocks affected completeness.

Process: Textile preparation and cutting/sewing (textile)

Inputs

Product flows
Polyester-viscose-polypropylene needle-punched nonwoven (nonwoven)

Only for the documented mixed-fibre nonwoven route; record actual blend, finish, areal mass and recycled-content evidence. A finished fabric input includes upstream fibre production once.

  • Selected flow: Polyester-viscose-polypropylene needle-punched nonwoven
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: beurer-ub60
Cotton woven fabric (cotton_fabric)

Only where an actual cotton fabric layer is purchased; never substitute for the documented nonwoven blend.

  • Selected flow: Cotton woven fabric
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
Polyester textile yarn (polyester_yarn)

Only for on-site weaving, knitting or insulating-yarn wrapping; distinguish fabric yarn from heater-core/overwrap yarn and do not duplicate purchased fabric.

  • Selected flow: Polyester textile yarn
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: woven-heater-patent
Polyester sewing thread (sewing_thread)

Only for the actual polyester seam or edging thread; other thread chemistry receives its own atomic row.

  • Selected flow: Polyester sewing thread
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
Purchased alternating-current electricity at factory supply voltage (textile_power)

Meter actual cutting, sewing, weaving and finishing; operating nameplate blanket wattage is not production consumption.

  • Selected flow: Purchased alternating-current electricity at factory supply voltage
  • Flow property / unit: Energy / kWh
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_utility.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_utility

Outputs

Waste flows
Polyester-viscose-polypropylene nonwoven offcut (fabric_offcut)

Only from the matching fabric route; weigh by blend and treatment destination; separate other textile waste.

  • Selected flow: Polyester-viscose-polypropylene nonwoven offcut
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material

Process: Heater manufacture or purchased-heater integration (heater)

Inputs

Product flows
Insulated electric-blanket heating cable (heater_cable)

Purchased complete cable branch: record conductor, separator, jacket and sensing architecture from supplier drawing. Do not also input its embedded conductor or resin.

  • Selected flow: Insulated electric-blanket heating cable
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: cable-heater-patent
Insulated stainless-steel conductive textile yarn (conductive_yarn)

Purchased complete conductive-yarn branch when actual architecture matches; this differs from coaxial cable. No simultaneous embedded filament/yarn inputs.

  • Selected flow: Insulated stainless-steel conductive textile yarn
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: woven-heater-patent
316L stainless-steel filament (steel_filament)

Only for actual on-site manufacture of the documented stainless conductive yarn; verify alloy, filament diameter and insulation design. Other heater alloys require separate rows.

  • Selected flow: 316L stainless-steel filament
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: woven-heater-patent
Polyethylene separator compound (separator_resin)

Only for on-site separator extrusion with actual qualified polyethylene formulation; additives and NTC/fusible behaviour require actual formulation evidence. Other jacket/separator formulations are separate rows, not assumed PVC.

  • Selected flow: Polyethylene separator compound
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: cable-heater-patent
Copper bus wire (copper_bus)

Only where actual bus/connection is uncoated copper; plated tinsel, conductive paste and other conductor chemistries require separate specific records.

  • Selected flow: Copper bus wire
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: woven-heater-patent
Purchased alternating-current electricity at factory supply voltage (heater_power)

Meter winding, extrusion, weaving-in or routing/attachment actually performed on site; purchased heater modules carry upstream fabrication once.

  • Selected flow: Purchased alternating-current electricity at factory supply voltage
  • Flow property / unit: Energy / kWh
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_utility.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_utility

Outputs

Waste flows
Insulated electric-blanket heating-cable offcut (heater_offcut)

Only for actual cable cutting scrap; composition and treatment destination must distinguish this from bare-metal recycling.

  • Selected flow: Insulated electric-blanket heating-cable offcut
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material

Process: Control, wiring and blanket assembly (assembly)

Inputs

Product flows
Electric-blanket temperature-control module (control_module)

Purchased tested controller: record actual switches, circuit, protective functions and housing included; no universal discrete thermostat, no additional embedded board/resin burden.

  • Selected flow: Electric-blanket temperature-control module
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: beurer-ub60
Electric-blanket populated control circuit board (control_board)

Only for controller assembled on site from a purchased board, instead of a complete control module; bare-board fabrication and solder chemistry need additional route-specific records when actually performed.

  • Selected flow: Electric-blanket populated control circuit board
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
ABS temperature-controller housing (control_housing)

Only if the actual separately purchased housing is ABS and controller is built on site; other polymers and on-site moulding require their own resin, energy and waste rows.

  • Selected flow: ABS temperature-controller housing
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
Electric-blanket temperature sensor (sensor)

Only for a separately purchased physical sensor in the actual design; cable-integrated sensing is included in its cable, not repeated here.

  • Selected flow: Electric-blanket temperature sensor
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: cable-heater-patent
Electric-blanket insulated mains cord with plug (power_cord)

Record actual plug geography, voltage and complete cord mass; count separately only when not included in purchased controller.

  • Selected flow: Electric-blanket insulated mains cord with plug
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: beurer-ub60
Electric-blanket detachable electrical coupling (coupling)

Only if separately supplied and not already embedded in heater/controller/cord; record contacts, housing and strain relief interface.

  • Selected flow: Electric-blanket detachable electrical coupling
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: beurer-ub60
Ethylene-vinyl-acetate hot-melt adhesive (adhesive)

Only for actual EVA adhesive lamination; actual grades and additives require evidence. Sewn-only route is not applicable; solvent-based adhesive is a separate formulated exchange with constituent balance.

  • Selected flow: Ethylene-vinyl-acetate hot-melt adhesive
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: woven-heater-patent
Isopropanol (isopropanol)

Only for actual cleaning chemistry; record concentration, recovery, retained residue and fate. Other cleaning solvents are separate species rows.

  • Selected flow: Isopropanol
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_chemistry.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_chemistry
Purchased alternating-current electricity at factory supply voltage (assembly_power)

Meter joining, crimping, controller assembly and lamination actually performed.

  • Selected flow: Purchased alternating-current electricity at factory supply voltage
  • Flow property / unit: Energy / kWh
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_utility.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_utility

Outputs

Waste flows
EVA hot-melt adhesive residue (adhesive_waste)

Only for actual EVA residue; record retained product and stock separately.

  • Selected flow: EVA hot-melt adhesive residue
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
Spent isopropanol cleaning liquid (solvent_waste)

Only for actual spent cleaner; assay water/isopropanol and other components, receiver and final treatment.

  • Selected flow: Spent isopropanol cleaning liquid
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_chemistry.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_chemistry
Elementary flows
Isopropanol to air (ipa_air)

Only measured or species-specific calculated air release; capture or unexplained solvent residual is not automatically air emission.

  • Selected flow: Isopropanol to air
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_chemistry.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_chemistry

Process: Acceptance tests and reject handling (test)

Inputs

Product flows
Purchased alternating-current electricity at factory supply voltage (test_power)

Meter actual continuity, insulation, temperature/protection and acceptance tests by batch; include failed/retested units. Do not multiply consumer power by arbitrary hours.

  • Selected flow: Purchased alternating-current electricity at factory supply voltage
  • Flow property / unit: Energy / kWh
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_utility.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_utility
Purchased process water (test_water)

Only for actual factory washability/wet test or cleaning; downstream consumer washing is outside factory scope.

  • Selected flow: Purchased process water
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_water.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_water

Outputs

Waste flows
Rejected electric blanket (rejected_blanket)

Unrecoverable actual reject crosses boundary to treatment; rework stays internal and its burden is retained once.

  • Selected flow: Rejected electric blanket
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
Electric-blanket wet-test wastewater (test_wastewater)

Only actual wet-test discharge with measured composition and treatment destination; water volume is not pollutant mass.

  • Selected flow: Electric-blanket wet-test wastewater
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_water.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_water
Elementary flows
Water vapour to air (evaporated_water)

Only actual evaporation inside factory scope, determined from closed water account and uncertainty; not inferred from consumer drying.

  • Selected flow: Water vapour to air
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_water.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_water

Process: Packaging and factory-gate dispatch (dispatch)

Inputs

Product flows
Corrugated cardboard packaging (cardboard)

Only actual dispatch box; measured separately from product mass.

  • Selected flow: Corrugated cardboard packaging
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
Polyethylene packaging bag (polybag)

Only actual polyethylene bag; other films receive separate atomic rows.

  • Selected flow: Polyethylene packaging bag
  • Flow property / unit: Mass / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material

Outputs

Product flows
Electric blankets (finished_blanket)

Accepted complete blanket with the actual included heater, control, cord and required accessories; packaging excluded from net mass.

  • Selected flow: Electric blankets db63276c-3e0f-4fe9-80de-b45ff12d515b
  • Flow property / unit: Mass / kg
  • Amount rule: 1 kg
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_mass

Process: Residual factory shared services (services)

Inputs

Product flows
Purchased alternating-current electricity at factory supply voltage (residual_power)

Only unassigned shared-service residual after every textile/heater/assembly/test/dispatch meter on the same site period; causal allocation, never whole-site total on top of submeter consumption.

  • Selected flow: Purchased alternating-current electricity at factory supply voltage
  • Flow property / unit: Energy / kWh
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_utility.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_utility

Outputs

7. Allocation and Co-product Handling

rule_idapplies_torulesource_ids
a_cohortall processesKeep each model/configuration and its actual accepted output separate. Allocate shared factory operations by measured causal activity (machine time, actual load or area-time), disclose the basis and reconcile to the original period totals. Do not average different heater/control/textile configurations.
a_scrapphysical material recordsInternal offcut or rework returns cancel as paired transfers, not free external inputs or coproduct credits. Include scrap conditioning and all rejected/reworked burden. External recycling or treatment uses documented receiver and allocation convention; do not assume avoided virgin material.

8. Foreground Data Collection, Calculation, and Quality Rules

Use one traceable site period and one configuration cohort. Q is the attributable period exchange, including its share of reject/rework and actual shared services; N is accepted complete units; D is the sum of individually calibrated accepted net masses for that same configuration; M = D/N. Form q_item = Q/N, then q_ref = q_item/M = Q/D. Packaging, rejected units and scrap never enter D. These are collection operations, not empirical default factors. Every protocol retains raw period totals before conversion.

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_massdispatchreference productweighingmodel; configuration; serial number; accepted net mass MWeigh the accepted complete unit on a calibrated scale, excluding transport packaging; reconcile the same configuration and acceptance record.kgeach accepted unitone production cohortdeclared factoryaccepted net mass per machinecalibration; acceptance and inclusion list
cp_materialall processesspecific material/component/wastestock and batch recordsgrade; fibre blend; supplier; delivered form; batch; opening/closing stock; issues; returns; scrap; reject; actual wet/dry mass; own species assay; destination; configuration; Q; NReconcile weighed receipts/issues/stocks, actual BOM, route and counted parts with calibrated batch weight. Each material/species has its own assay for each product/waste/release term. Pair internal return transfers. Count complete purchased component upstream once.kgeach batch and period closesame production periodactual factory operation and supplier interfaceattributable exchange / accepted unitsweighbridge/scale; supplier composition; stock reconciliation; receiver evidence
cp_utilityall processeselectricitymeter recordssite; period; units; voltage; imports; generation; exports; storage; returns; all submeters; configuration; causal allocation; Q; NRead calibrated same-period meters and invoices. Assign actual textile/heater/assembly/test/dispatch loads first; shared service is only the unassigned site residual. Reconcile imports, actual generation, exports and storage changes without double counting. Investigate negative residuals with period/unit/combined meter uncertainty; never clip to zero. On-site generation needs its own fuel and species-specific release rows.kWheach test batch and periodsame production periodfactory utility boundaryattributable exchange / accepted unitsmeter calibration; bills; allocation and site reconciliation
cp_chemistryassemblyindividual adhesive/solvent/specieschemical and sampling recordschemical grade; formulation; purity; wet/dry basis; actual inputs; stock changes; retained product; recovered solvent; capture media; measured destruction; waste liquid; actual air release; Q; NMeasure species mass for each term using its own matched assay; balance inputs plus reaction production against product retention, stocks, recovered material, captures, liquid/solid waste, actual destruction/reaction consumption and measured releases. Capture is not destruction; unexplained residual is not automatically air. Resolve closure against actual combined sampling, meter and allocation uncertainty.kgeach batch and sampled campaignsame production periodactual chemical use boundaryattributable exchange / accepted unitsSDS/formulation; assays; capture/treatment records; sampling method and uncertainty
cp_watertestwater and wet-test dischargemeter and moisture recordspurchased water; feed moisture; opening/closing water stocks; actual product moisture; evaporation; discharge; reaction production/consumption; paired internal returns; discharge assays; Q; NMeasure all actual water-bearing inputs, outputs and stock changes on matched period/basis. Each feed, product, scrap, sludge, wastewater and opening/closing stock term uses its own measured water fraction/moisture; each liquid volume conversion uses its own measured density. Gross wet-waste mass is not water mass; never apply one moisture percentage to all terms. Include reaction water and pair internal returns; independently measure discharge/evaporation where available and investigate residual against combined uncertainty. Pollutant mass uses each discharge species concentration and actual water quantity; do not infer pollutant amount from water alone.kgeach wet-test batch and periodsame production periodfactory wet operationattributable exchange / accepted unitsmeters; moisture samples; laboratory assay; treatment contract

Actual raw-period water closure is fresh-water input + feed moisture + opening water stock + reaction water generation = product moisture + scrap/sludge water + external discharge water + evaporation + closing water stock + reaction water consumption. Separate each actual aqueous waste stream and use its own assay/density; paired internal water returns cancel. Investigate closure with combined measurement, sampling and allocation uncertainty before normalization; no universal closure tolerance.

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
normalize_massall inventory rowsq_ref = q_item / M; q_item = exchange amount per one accepted finished unit; q_ref = exchange amount per 1 kg reference flow.q_item; M; cp_massq_ref
water_balancetest_water; test_wastewater; evaporated_waterFresh water + feed moisture + opening water stock + reaction water generation = product moisture + scrap water + sludge water + external discharge water + evaporation + closing water stock + reaction water consumption. Each actual feed/product/scrap/sludge/wastewater/stock term uses its own measured water fraction and wet/dry basis; each liquid volume uses its own measured density. Gross wet waste is not water mass. Paired internal returns cancel. Reconcile the actual raw period before normalization and investigate closure with combined measurement, sampling and allocation uncertainty; no universal tolerance.cp_water; actual water fractions; actual liquid densities; matched raw-period water and reaction/stock recordsClosed actual raw-period water account

Data Quality Requirements

requirement_idApplies toRequirementEvidence
dq_traceall processesRetain actual model-specific BOM, make/buy matrix, test acceptance, raw totals, uncertainty, supplier interfaces and missing/zero/absent distinctions. Source patents are architecture examples; public product pages establish no factory operating factors.Signed factory and supplier records
dq_balancephysical material and species recordsMaterial/species inputs plus reaction production equal outputs plus stock increase and reaction consumption after paired internal transfers cancel. Each product/scrap/sludge/wastewater/release term uses its own actual assay and wet/dry basis; never apply one alloy fraction to all terms. Investigate imbalance against measured combined uncertainty with no universal tolerance. Fuel carbon alone does not determine CO or NOx.Assays; stock/reaction records; closure and uncertainty report

9. Validation Rules

rule_idapplies_torulesource_ids
v_referencereference productRequire actual domestic principal function, model/configuration qualifiers, accepted complete delivered inclusion list and calibrated net masses. N and D must cover the same accepted cohort; M = D/N; reconcile Q/N then q_item/M to Q/D. Do not mix configurations or include packaging/reject mass in D.
v_routesall processesEvery actual heater conductor, insulation layer, textile, controller/sensor, cord/connector, adhesive and auxiliary has one evidenced make/buy interface. Complete purchased modules and their embedded inputs cannot coexist. Conditional alternatives require BOM evidence; not_applicable needs verified absence. All actual exchanges have atomic physical/chemical identities, matched unit support and provider interfaces; unresolved fields remain gaps.
v_balancesphysical material and species recordsClose each material/species and water account with matched own assays, moisture, stocks, reactions, product, scrap, waste liquid/solid, measured releases and paired internal returns. Distinguish recovery, capture and actual destruction. Investigate residual and uncertainty; missing composition or fate makes affected validation inconclusive.
v_energyutility recordsSame-period site reconciliation binds imports, generation, exports/storage and all assigned process loads. Shared services include only unassigned residual, with causal allocation. Negative residuals need investigation; consumer power/time, product-webpage mass and an incineration-specific electricity UUID are not factory defaults.

10. Published Dataset Profile

FieldValue
dataset_rolesecondary_dataset; background_dataset
downstream_useDataset-production foreground package, projected to process or lifecyclemodel with separately declared downstream scenarios
allowed_useMatched configuration and plant-gate domestic blanket supply
excluded_useUnqualified blanket averages; medical service; body/room heating service without use scenario; unfinished heater as complete blanket
required_metadataAll reference qualifiers; site/time; actual route and inclusion list; allocation; supplier matching; complete raw-period conversion
required_quality_disclosureSources, measurement/sampling uncertainty, unresolved UUID/provider/recipe gaps, actual balance closure and validation coverage
update_triggerChanged textile/heater/insulation/control design, make/buy boundary, supplier, geography, test method or site period

11. Data Sources

Source idTypeReferenceUsed for
beurer-ub60handbookhttps://www.beurer.com/global/p/30036/ — UB 60 Green Planet; snapshot 2026-10-02Underblanket example; actual mixed-fibre nonwoven, removable control/power interface, temperature monitoring. No universal composition or factory quantity.
beurer-throwshandbookhttps://www.beurer.com/global/c/0020103/ — Heated Throws; snapshot 2026-10-02Domestic overblanket examples; consumer washing/operation are separate. Same publisher as UB60, not independent evidence.
woven-heater-patentliteratureUS6888112B2 (2005-05-03), https://patents.google.com/patent/US6888112B2/enIndependent original technical disclosure: integrated conductive yarn, stainless-filament/polyester example, finishing and bus connection variants. Patent embodiments are conditional architecture, not actual factory recipe or quantitative ranges.
cable-heater-patentliteratureUS8698045B2 (2014-04-15), https://patents.google.com/patent/US8698045B2/enIndependent original technical disclosure: coaxial conductor/separator/jacket, cable-integrated sensing and polyethylene example. Broad pad terminology does not establish domestic-blanket classification. No mandated polymer/alloy or operating default.

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 2
Rule IDApplies toRuleSource IDs
b_makebuyall processesFor each textile layer, heater, controller and connection, choose complete purchased component or on-site fabrication. The former includes its embedded materials upstream once; the latter records every actual individual grade, chemical, utility, waste and release. Add distinct atomic rows for actual alternatives not listed here; examples are not compulsory recipes.
b_factoryall processesInclude transport into the declared factory boundary, actual conversion, joining, testing, rework, reject treatment and packaging; transport providers require separate mode-specific freight rows. Later space/body heating, laundering, product lifetime and disposal belong only to explicitly separate lifecycle scenarios.
Allocation rules · 2
Rule IDApplies toRuleSource IDs
a_cohortall processesKeep each model/configuration and its actual accepted output separate. Allocate shared factory operations by measured causal activity (machine time, actual load or area-time), disclose the basis and reconcile to the original period totals. Do not average different heater/control/textile configurations.
a_scrapphysical material recordsInternal offcut or rework returns cancel as paired transfers, not free external inputs or coproduct credits. Include scrap conditioning and all rejected/reworked burden. External recycling or treatment uses documented receiver and allocation convention; do not assume avoided virgin material.
Validation rules · 4
Rule IDApplies toRuleSource IDs
v_referencereference productRequire actual domestic principal function, model/configuration qualifiers, accepted complete delivered inclusion list and calibrated net masses. N and D must cover the same accepted cohort; M = D/N; reconcile Q/N then q_item/M to Q/D. Do not mix configurations or include packaging/reject mass in D.
v_routesall processesEvery actual heater conductor, insulation layer, textile, controller/sensor, cord/connector, adhesive and auxiliary has one evidenced make/buy interface. Complete purchased modules and their embedded inputs cannot coexist. Conditional alternatives require BOM evidence; not_applicable needs verified absence. All actual exchanges have atomic physical/chemical identities, matched unit support and provider interfaces; unresolved fields remain gaps.
v_balancesphysical material and species recordsClose each material/species and water account with matched own assays, moisture, stocks, reactions, product, scrap, waste liquid/solid, measured releases and paired internal returns. Distinguish recovery, capture and actual destruction. Investigate residual and uncertainty; missing composition or fate makes affected validation inconclusive.
v_energyutility recordsSame-period site reconciliation binds imports, generation, exports/storage and all assigned process loads. Shared services include only unassigned residual, with causal allocation. Negative residuals need investigation; consumer power/time, product-webpage mass and an incineration-specific electricity UUID are not factory defaults.
Processes and inputs/outputs · 6
Process IDProcess nameInput flowsOutput flows
textileTextile preparation and cutting/sewing51
heaterHeater manufacture or purchased-heater integration61
assemblyControl, wiring and blanket assembly93
testAcceptance tests and reject handling23
dispatchPackaging and factory-gate dispatch21
servicesResidual factory shared services10

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page