TianGong PCR

Centrifugal clothes driers (standalone spin extractors)

Lifecycle status
Candidate
Content maturity
Authored methodology
Current version
No published versionLast updated
Readiness
Review required

Methodology and translation states come from the source record; publishing this website does not change their review status.

Content languages

en-US · canonicalzh-CN · Aligned
Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:44911 · exact

Source

1. Scope and Applicability

This candidate governs foreground manufacturing data for finished standalone devices that remove water from already washed clothes/linen by centrifugal basket rotation. It covers compact household spin dryers and commercial/industrial hydro-extractors, separately by configuration; the CPC 3.0 centrifugal subclass has no laundry-capacity split. It excludes integrated washer-extractors, combined domestic washer/dryers, heated tumble or heat-pump dryers, drying cabinets, textile dyeing/finishing centrifuges not supplied for clothes/linen extraction, food/process centrifuges, and independently supplied parts. Equipment kilograms are an inventory reference, not an equal laundry service across models. [un-cpc-3-0; thomas-centri; fabcare-extractor; swastik-extractor]

Household examples demonstrate the semantic centrifugal function, not an automatic CPC assignment. CPC 3.0 also names household washing/drying in 44812; assess actual design, sole/principal function, marketed use and authoritative classification evidence before assigning an individual household device. HS 2022 separately places centrifugal clothes dryers in 8421.12 and washing machines with built-in centrifugal driers in 8450.12, subject to Chapter 84 notes; this is supporting physical boundary evidence, not a published CPC3 correspondence or ruling for every model. [un-cpc-3-0; wco-hs2022-84]

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.metal-products-machinery-and-equipment.special-purpose-machinery.centrifugal-clothes-driers
classification_refsCPC 3.0 44911
covered_productsComplete standalone household or commercial/industrial centrifugal clothes extractors
excluded_productsIntegrated washing functions, heated drying devices, unrelated centrifuges and parts
representative_productOne configured accepted basket extractor with supplied motor, enclosure, drive, suspension, controls and safety system
production_routePurchased-subassembly assembly or actual conditional site fabrication, finish and motor production, followed by factory tests and dispatch
market_stateFinished tested complete device at manufacturer gate; installation foundations and downstream laundry operation separate

3. Reference Flow

FieldValue
WhatSupply a complete standalone clothes-water extraction device
How muchManufacturing inventory per 1 kg accepted net device mass
How wellActual specified dry-laundry capacity, spin speed, imbalance/safety and drain acceptance; no universal moisture performance
How long or cycleOne manufacturing reporting period through accepted gate; service life and subsequent spin cycles are separate study parameters
reference_flow_linkfinished
FieldValue
Reference amount1
Reference product flowCentrifugal clothes driers c6fb37f3-a8e3-4178-99c5-c2dd06e2dac1
Reference flow propertyMass 93a60a56-a3c8-11da-a746-0800200b9a66
Reference unit groupUnits of mass 93a60a57-a4c8-11da-a746-0800200c9a66
Reference unitkg
Required qualifiersmodel and BOM revision; household/industrial family; dry-laundry capacity distinct from device mass; basket alloy and dimensions; enclosure/finish; motor phase/power; direct/belt/VFD drive and braking; suspension/bearings; safety interlock; supplied optional loading device; net accepted mass; make/buy and delivered states; factory test plan/load; site/period; supply voltage/geography; packaging; provider/treatment links

Declare all qualifiers in the data package. Never use rated laundry-load kg, a brochure example weight or boxed mass as the denominator. The generic category UUID does not supply a model BOM or upstream provider.

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
net_massreference productMass 93a60a56-a3c8-11da-a746-0800200b9a66kgCollect using cp_mass: calibrated weighing of accepted complete devices, excluding transport packaging, wet test cloth, retained water and installation foundations; preserve same model/configuration and acceptance record.
period_basisphysical exchange normalizationMasskgFor the same configuration and period N is accepted units, D is sum of their calibrated net masses, M = D/N, Q is attributable external period quantity including setup, rework and rejected production. q_item = Q/N and q_ref = q_item/M = Q/D. N and D must be positive; no mass mixing across configurations.
physical_assayphysical material and chemical species recordsMasskgMatch wet/dry basis, moisture and each individual species/metal assay on every material, stock, product, waste and release term; gross alloy or sludge mass is not contained Fe, Cr or Ni mass. This rule does not assign mass assays to electricity or transport.
energy_basisenergy recordsDelivered energyMJPreserve measured kWh, convert using 1 kWh = 3.6 MJ. Fuel remains specific kg with measured composition/NCV; regeneration exported during actual factory tests is separately metered, never an assumed use-phase saving.

5. System Boundary

rule_idApplies toRulesource_ids
gateforegroundInclude actual delivered-input receipt through fabrication, finish, motor make when present, assembly, balancing/acceptance, rework, rejects, residual utilities and packing before release.
make_buycomponent stateEach bought motor, drum, shaft, bearing housing, drive or control carries completed upstream production once; do not add embedded metals, resin, copper, oil or component-factory energy again. Site make instead uses actual raw inputs and stages; paired internal part transfers cancel but processing burdens remain.
factory_testtestingInclude electricity, actual consumed cloth/water, pneumatic-lock compressor load and rejects from the actual factory spin, vibration, lid-lock, braking, electrical and drain/leak plan. Model raw wet-cloth moisture and retained returns; consumer instructions demonstrate function, not a mandatory factory test recipe.thomas-instructions; ifb-inc100
downstreamlater useExclude customer laundry electricity, washing detergent/water, subsequent tumble drying, operation replacements, installation concrete and end of life from the manufacturing foreground; retain separate downstream links when study requires them. No heated drying process is inferred from the word drier.un-cpc-3-0; thomas-centri
route_auditspecific exchangesEach card is conditional on documented recipe/BOM, not a universal materials basket. Add every actual alloy, polymer, purchased part, utility, formulation constituent, packaging, treatment and emission as its own exchange. not_applicable requires absence evidence; unknown never equals zero. External transport and upstream/treatment links remain explicit.

Boundary Abstraction

FieldValue
declared_starting_conditionActual delivered sheet, finished parts, motor, drive, control and packaging at documented supplier processing states
starting_condition_roleForeground primary-production receipt boundary
product_classification_scopeStandalone centrifugal clothes-water extraction; household size alone does not make it a washer or heated dryer
recursive_input_ruleSame-category bought complete device for actual refurbishment uses its delivered-state dataset once and a separately declared refurbishment gate; never represent new production by recursively purchasing itself
upstream_dataset_requirementExact material, completed operations, component interface, geography/period and voltage; missing providers disclosed
disclosureComplete BOM/make-buy matrix, delivered configuration, test plan, net output period, allocation, upstream transport/treatment and missing data

Configuration and make/buy matrix

AssemblyAlternatives and requirement
Basket/enclosureBought formed/perforated/balanced stainless basket vs actual site fabrication; THOMAS metal drum and impact-resistant cover do not establish one universal polymer or alloy. Fabcare 304 drum and galvanized base are configuration evidence, not all-site defaults.
Drive/brakeDirect drive, verified conventional transmission or VFD variant; mechanical brake/clutch are conditional. Swastik VFD replaces them and may regenerate; IFB non-coaxial headline conflicts with direct-drive prose, so actual drawing/nameplate governs.
Suspension/safety/controlTHOMAS flexible motor/drum suspension and one-hand lid lock differ from Swastik spring/roller/thrust-bearing construction and IFB pneumatic lid lock. Timer, PLC, brake, damper and pneumatic actuator are included only when actually delivered.
Motor and finishesBought finished motor/painted parts use upstream datasets once; actual in-house winding/impregnation, casting, molding, plating/galvanizing and painting require their own complete recipes, external utilities and emissions. No unobserved route is mandatory.

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
fabricationBasket, drum, frame and shaft fabricationconditionalOnly actual in-house cutting, perforating, forming, welding and machining; bought completed parts bypass corresponding stagesForeground manufacturing recordsper 1 kg reference flow
finishConditional surface cleaning and coatingconditionalOnly actual cleaning/painting/curing before the supplied finish gate; bare stainless and bought finished parts bypass this routeForeground manufacturing recordsper 1 kg reference flow
motor_makeConditional in-house motor productionconditionalOnly documented motor fabrication/winding/impregnation and testing; whole purchased motor excludes embedded inputsForeground manufacturing recordsper 1 kg reference flow
assemblyMechanical, electrical and safety assemblyrequiredActual BOM, drive and suspension configuration; directly purchased subassemblies versus site-made internal transfersForeground manufacturing recordsper 1 kg reference flow
testFactory balancing and acceptance testingrequiredActual dry/wet spin, vibration, lid interlock/braking, electrical and drain/leak tests before releaseForeground manufacturing recordsper 1 kg reference flow
sharedShared factory servicesconditionalOnly unassigned residual utilities after measured process loads, including test air-compressor electricity if not already assignedForeground manufacturing recordsper 1 kg reference flow
dispatchPacking and accepted extractor releaserequiredAll products; accepted configuration and complete supplied device onlyForeground manufacturing recordsper 1 kg reference flow

Process: Basket, drum, frame and shaft fabrication (fabrication)

Only actual in-house cutting, perforating, forming, welding and machining; bought completed parts bypass corresponding stages

Inputs

Product flows
AISI 304 stainless steel sheet (ss304_sheet)

Only for site-made basket or outer drum with documented 304 grade; bought completed drums exclude this input.

  • Selected flow: AISI 304 stainless steel sheet

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: fabcare-extractor

Carbon steel sheet for extractor frame (carbon_sheet)

Only actual specified carbon-steel frame fabrication; do not infer grade from appearance.

  • Selected flow: Carbon steel sheet for extractor frame

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources:

Alloy steel shaft bar (shaft_bar)

For a site-machined shaft of the certified alloy only; purchased finished shafts take the assembly route.

  • Selected flow: Alloy steel shaft bar

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: swastik-extractor

ER308L stainless steel welding wire (welding_wire)

Only an actual compatible ER308L joining specification; other filler grades need separate records.

  • Selected flow: ER308L stainless steel welding wire

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources:

Argon welding shielding gas (argon)

Only when argon shielding is consumed in site joining; gas mixture constituents require individual cards.

  • Selected flow: Argon welding shielding gas

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources:

Mineral-oil cutting fluid (cutting_oil)

Actual machining fluid of declared formulation; record concentrate and make-up water separately.

  • Selected flow: Mineral-oil cutting fluid

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources:

Alternating current (fabrication_power)

Only actual purchased CN <1 kV customer-side supply; record disjoint assigned process load, including rework and idle. For shared services only the unassigned measured residual after these process loads; other supply voltage/geography needs a matched separate identity.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7

  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ

  • Amount rule: Use the attributable period amount measured under cp_energy; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_energy

  • Sources:

Outputs

Waste flows
AISI 304 stainless steel fabrication scrap (ss_trim)

Only segregated 304 trim or rejects leaving the factory; internal remelt returns are paired transfers.

  • Selected flow: AISI 304 stainless steel fabrication scrap

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_waste; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_waste

  • Sources:

Alloy steel shaft machining chips (steel_chip)

Actual alloy-specific chips with oil/moisture assay; never equate wet gross weight to contained metal.

  • Selected flow: Alloy steel shaft machining chips

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_waste; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_waste

  • Sources:

Carbon steel sheet fabrication scrap (carbon_trim)

Actual carbon-steel trim separated from stainless steel.

  • Selected flow: Carbon steel sheet fabrication scrap

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_waste; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_waste

  • Sources:

Spent mineral-oil cutting fluid (spent_oil)

Actual spent machining fluid leaving for identified treatment.

  • Selected flow: Spent mineral-oil cutting fluid

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_waste; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_waste

  • Sources:

Stainless steel welding fume filter dust (weld_dust)

Captured fume is waste; distinguish each contained element by its own measured assay.

  • Selected flow: Stainless steel welding fume filter dust

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_waste; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_waste

  • Sources:

Process: Conditional surface cleaning and coating (finish)

Only actual cleaning/painting/curing before the supplied finish gate; bare stainless and bought finished parts bypass this route

Inputs

Product flows
Epoxy powder coating (epoxy_powder)

Only if the actual enclosure/frame uses this specified coating; bare stainless construction has no coating default.

  • Selected flow: Epoxy powder coating

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources:

Isopropanol cleaning solvent (isopropanol)

Only actual factory solvent cleaning with isopropanol; retain recipe and solvent recovery.

  • Selected flow: Isopropanol cleaning solvent

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources:

Deionized rinse water (finish_water)

Only actual factory surface rinse, not consumer laundry water.

  • Selected flow: Deionized rinse water

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_water; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_water

  • Sources:

Natural gas for coating oven (natural_gas)

Only a site gas-fired curing oven, with actual composition and net calorific value; electric ovens use measured electricity instead.

  • Selected flow: Natural gas for coating oven

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_energy; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_energy

  • Sources:

Alternating current (finish_power)

Only actual purchased CN <1 kV customer-side supply; record disjoint assigned process load, including rework and idle. For shared services only the unassigned measured residual after these process loads; other supply voltage/geography needs a matched separate identity.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7

  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ

  • Amount rule: Use the attributable period amount measured under cp_energy; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_energy

  • Sources:

Outputs

Waste flows
Epoxy powder coating waste (powder_waste)

Only powder leaving after separately recorded internal recovery.

  • Selected flow: Epoxy powder coating waste

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_waste; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_waste

  • Sources:

Metal-bearing surface-cleaning sludge (finish_sludge)

Actual sludge, with wet/dry basis and separate Fe, Cr, Ni and any other measured species assays.

  • Selected flow: Metal-bearing surface-cleaning sludge

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_waste; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_waste

  • Sources:

Surface-cleaning wastewater (finish_effluent)

Only water transferred for external treatment; direct environmental releases need distinct compartment/species rows.

  • Selected flow: Surface-cleaning wastewater

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_waste; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_waste

  • Sources:

Spent isopropanol cleaning solvent (solvent_waste)

Actual spent solvent with assay, recovered and retained fractions kept distinct.

  • Selected flow: Spent isopropanol cleaning solvent

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_waste; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_waste

  • Sources:

Elementary flows
Isopropanol, emission to air (isopropanol_air)

Only actual uncaptured release after solvent accounting and measurement; destruction is not automatic air loss.

  • Selected flow: Isopropanol, emission to air

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_emission; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_emission

  • Sources:

Carbon dioxide, fossil, emission to air (co2_air)

Only the actual gas-fired oven release after controls; CO and nitrogen species each require their own measured concentration or valid species-specific factor.

  • Selected flow: Carbon dioxide, fossil, emission to air

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_emission; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_emission

  • Sources:

Carbon monoxide, emission to air (co_air)

Only the actual gas-fired oven release after controls; CO and nitrogen species each require their own measured concentration or valid species-specific factor.

  • Selected flow: Carbon monoxide, emission to air

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_emission; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_emission

  • Sources:

Nitrogen monoxide, emission to air (no_air)

Only the actual gas-fired oven release after controls; CO and nitrogen species each require their own measured concentration or valid species-specific factor.

  • Selected flow: Nitrogen monoxide, emission to air

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_emission; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_emission

  • Sources:

Nitrogen dioxide, emission to air (no2_air)

Only the actual gas-fired oven release after controls; CO and nitrogen species each require their own measured concentration or valid species-specific factor.

  • Selected flow: Nitrogen dioxide, emission to air

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_emission; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_emission

  • Sources:

Process: Conditional in-house motor production (motor_make)

Only documented motor fabrication/winding/impregnation and testing; whole purchased motor excludes embedded inputs

Inputs

Product flows
Enamelled copper motor winding wire (winding_wire)

Only documented in-house motor winding, rather than bought complete motor.

  • Selected flow: Enamelled copper motor winding wire

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources:

Electrical steel motor laminations (laminations)

Only site-made motor assembly from purchased laminations; no raw steel or punching burden duplicated.

  • Selected flow: Electrical steel motor laminations

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources:

Epoxy motor winding impregnation varnish (varnish)

Only actual epoxy impregnation formulation; retain solvent constituents and cure schedule separately.

  • Selected flow: Epoxy motor winding impregnation varnish

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources:

Alternating current (motor_make_power)

Only actual purchased CN <1 kV customer-side supply; record disjoint assigned process load, including rework and idle. For shared services only the unassigned measured residual after these process loads; other supply voltage/geography needs a matched separate identity.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7

  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ

  • Amount rule: Use the attributable period amount measured under cp_energy; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_energy

  • Sources:

Outputs

Waste flows
Enamelled copper winding-wire scrap (wire_scrap)

Actual winding rejects with copper assay and insulation mass distinguished.

  • Selected flow: Enamelled copper winding-wire scrap

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_waste; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_waste

  • Sources:

Process: Mechanical, electrical and safety assembly (assembly)

Actual BOM, drive and suspension configuration; directly purchased subassemblies versus site-made internal transfers

Inputs

Product flows
Finished stainless steel extractor basket (bought_basket)

Only bought basket; actual alloy, perforation and balancing state.

  • Selected flow: Finished stainless steel extractor basket

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: swastik-extractor; fabcare-extractor; thomas-centri; ifb-inc100

Finished extractor outer drum (bought_outer)

Only bought drum; stainless or galvanized construction must follow actual specification.

  • Selected flow: Finished extractor outer drum

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: swastik-extractor; fabcare-extractor; thomas-centri; ifb-inc100

Finished alloy steel extractor shaft (bought_shaft)

Only bought completed shaft; no parallel raw bar burden.

  • Selected flow: Finished alloy steel extractor shaft

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: swastik-extractor; fabcare-extractor; thomas-centri; ifb-inc100

Cast iron extractor bearing housing (bearing_housing)

Only specified cast-iron purchased housing; casting and embedded iron are upstream once.

  • Selected flow: Cast iron extractor bearing housing

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: swastik-extractor; fabcare-extractor; thomas-centri; ifb-inc100

Spring steel suspension spring (spring)

Only a delivered spring suspension variant.

  • Selected flow: Spring steel suspension spring

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: swastik-extractor; fabcare-extractor; thomas-centri; ifb-inc100

Rubber vibration-isolation mount (damper)

Only an actual rubber mount; retain compound, geometry and flexible-suspension specification.

  • Selected flow: Rubber vibration-isolation mount

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: swastik-extractor; fabcare-extractor; thomas-centri; ifb-inc100

Extractor electric drive motor (motor)

Bought motor with actual phase, power, brake/insulation interface and delivered winding state; embedded copper and steel are not separate assembly inputs.

  • Selected flow: Extractor electric drive motor

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: swastik-extractor; fabcare-extractor; thomas-centri; ifb-inc100

Extractor variable frequency drive (vfd)

Only VFD variant; Swastik source does not require a separate mechanical brake or clutch.

  • Selected flow: Extractor variable frequency drive

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: swastik-extractor; fabcare-extractor; thomas-centri; ifb-inc100

Electromagnetic extractor brake (brake)

Only an actual separate electromagnetic brake; DC-injection braking may be supplied by controls without this component.

  • Selected flow: Electromagnetic extractor brake

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: swastik-extractor; fabcare-extractor; thomas-centri; ifb-inc100

Rubber extractor drive belt (belt)

Only verified belt-drive configuration; direct drive is not charged a belt.

  • Selected flow: Rubber extractor drive belt

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: swastik-extractor; fabcare-extractor; thomas-centri; ifb-inc100

Steel extractor drive pulley (pulley)

Only actual belt transmission with steel pulley.

  • Selected flow: Steel extractor drive pulley

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: swastik-extractor; fabcare-extractor; thomas-centri; ifb-inc100

Steel roller bearing (bearing)

Actual roller bearing separately from shaft and housing.

  • Selected flow: Steel roller bearing

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: swastik-extractor; fabcare-extractor; thomas-centri; ifb-inc100

Steel thrust bearing (thrust_bearing)

Only specified thrust bearing, separately from roller-bearing inputs.

  • Selected flow: Steel thrust bearing

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: swastik-extractor; fabcare-extractor; thomas-centri; ifb-inc100

Extractor electronic timer (timer)

Only actual electronic timed control; mechanical lever control requires its own actual device.

  • Selected flow: Extractor electronic timer

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: swastik-extractor; fabcare-extractor; thomas-centri; ifb-inc100

Extractor lid safety interlock switch (lid_switch)

Actual lid interlock; preserve safety-circuit configuration.

  • Selected flow: Extractor lid safety interlock switch

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: swastik-extractor; fabcare-extractor; thomas-centri; ifb-inc100

Pneumatic extractor lid lock (pneumatic_lock)

Only IFB-like pneumatic lock configuration; air production belongs in factory tests if consumed before gate.

  • Selected flow: Pneumatic extractor lid lock

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: swastik-extractor; fabcare-extractor; thomas-centri; ifb-inc100

Impact-resistant polymer extractor lid (lid)

Only bought polymer lid with actual polymer identity; OEM impact-resistant description does not prove PP or ABS.

  • Selected flow: Impact-resistant polymer extractor lid

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: swastik-extractor; fabcare-extractor; thomas-centri; ifb-inc100

Finished extractor steel enclosure (enclosure)

Only bought enclosure with actual finish and alloy; no duplicate on-site sheet or coating inputs.

  • Selected flow: Finished extractor steel enclosure

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: swastik-extractor; fabcare-extractor; thomas-centri; ifb-inc100

Insulated copper extractor power cable (cable)

Actual incoming cable with specified conductor and insulation.

  • Selected flow: Insulated copper extractor power cable

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: swastik-extractor; fabcare-extractor; thomas-centri; ifb-inc100

Polymer extractor drain hose (hose)

Only supplied hose, with polymer declared; open-spout units need no hose default.

  • Selected flow: Polymer extractor drain hose

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: swastik-extractor; fabcare-extractor; thomas-centri; ifb-inc100

Carbon steel extractor fastening bolt (fastener)

Actual bolt grade, coating and delivered quantity; other fastener alloys require separate cards.

  • Selected flow: Carbon steel extractor fastening bolt

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: swastik-extractor; fabcare-extractor; thomas-centri; ifb-inc100

Lithium-soap mineral-oil bearing grease (grease)

Only actual first fill outside bought sealed-bearing burden; retain grade and SDS.

  • Selected flow: Lithium-soap mineral-oil bearing grease

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: swastik-extractor; fabcare-extractor; thomas-centri; ifb-inc100

Alternating current (assembly_power)

Only actual purchased CN <1 kV customer-side supply; record disjoint assigned process load, including rework and idle. For shared services only the unassigned measured residual after these process loads; other supply voltage/geography needs a matched separate identity.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7

  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ

  • Amount rule: Use the attributable period amount measured under cp_energy; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_energy

  • Sources:

Extractor motorized basket-loading hoist (loading_device)

Only an optional delivered loading device with actual supplier configuration; external laundry material handling is downstream.

  • Selected flow: Extractor motorized basket-loading hoist

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: swastik-extractor

Process: Factory balancing and acceptance testing (test)

Actual dry/wet spin, vibration, lid interlock/braking, electrical and drain/leak tests before release

Inputs

Product flows
Factory test water (test_water)

Only water actually introduced for wet-cloth spin, drain, or leak acceptance tests; distinguish initial wet-cloth moisture and internal returns.

  • Selected flow: Factory test water

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_water; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_water

  • Sources: thomas-instructions

Cotton acceptance-test cloth (test_cloth)

Only actually consumed cotton cloth; reusable test stock is not newly consumed each cycle. Record damage, replacement and wet/dry mass.

  • Selected flow: Cotton acceptance-test cloth

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_material; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_material

  • Sources: thomas-instructions

Alternating current (test_power)

Only actual purchased CN <1 kV customer-side supply; record disjoint assigned process load, including rework and idle. For shared services only the unassigned measured residual after these process loads; other supply voltage/geography needs a matched separate identity.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7

  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ

  • Amount rule: Use the attributable period amount measured under cp_energy; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_energy

  • Sources:

Purchased compressed air for acceptance test (purchased_air)

Only when compressed air crosses the factory boundary from an external provider; in-house compressor electricity is charged once instead.

  • Selected flow: Purchased compressed air for acceptance test

  • Flow property / unit: Volume / m3

  • Amount rule: Use the attributable period amount measured under cp_air; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_air

  • Sources:

Outputs

Product flows
Factory-test regenerated electricity exported (regenerated_power)

Only actual measured electricity leaving to the grid during regenerative spin tests; match export voltage/provider and do not use a consumer operating saving as its amount.

  • Selected flow: Factory-test regenerated electricity exported

  • Flow property / unit: Delivered electrical energy / MJ

  • Amount rule: Use the attributable period amount measured under cp_energy; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_energy

  • Sources:

Waste flows
Extractor factory-test wastewater (test_effluent)

Actual test discharge sent to treatment, not the customer-use discharge.

  • Selected flow: Extractor factory-test wastewater

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_waste; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_waste

  • Sources:

Spent cotton acceptance-test cloth (cloth_waste)

Only consumed cloth leaving stock with moisture specified; retained reuse cancels internal transfer.

  • Selected flow: Spent cotton acceptance-test cloth

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_waste; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_waste

  • Sources:

Rejected complete centrifugal clothes extractor (rejected_device)

Only unrecoverable rejected device sent to identified treatment; preserve its actual composition, wet/dry state and embedded burden; it never increases accepted D.

  • Selected flow: Rejected complete centrifugal clothes extractor

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_waste; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_waste

  • Sources:

Process: Shared factory services (shared)

Only unassigned residual utilities after measured process loads, including test air-compressor electricity if not already assigned

Inputs

Product flows
Alternating current (shared_power)

Only actual purchased CN <1 kV customer-side supply; record disjoint assigned process load, including rework and idle. For shared services only the unassigned measured residual after these process loads; other supply voltage/geography needs a matched separate identity.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7

  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ

  • Amount rule: Use the attributable period amount measured under cp_energy; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_energy

  • Sources:

Process: Packing and accepted extractor release (dispatch)

All products; accepted configuration and complete supplied device only

Inputs

Product flows
Alternating current (dispatch_power)

Only actual purchased CN <1 kV customer-side supply; record disjoint assigned process load, including rework and idle. For shared services only the unassigned measured residual after these process loads; other supply voltage/geography needs a matched separate identity.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7

  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ

  • Amount rule: Use the attributable period amount measured under cp_energy; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_energy

  • Sources:

Corrugated cardboard shipping carton (carton)

Only actual supplied carton, outside reference device mass.

  • Selected flow: Corrugated cardboard shipping carton

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_pack; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_pack

  • Sources:

Wood shipping pallet (pallet)

Only actual pallet, with reusable allocation based on documented trips and replacement.

  • Selected flow: Wood shipping pallet

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_pack; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_pack

  • Sources:

Polyethylene shipping film (film)

Only actual PE shipping film, never inferred from all packaging mass.

  • Selected flow: Polyethylene shipping film

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: Use the attributable period amount measured under cp_pack; divide by accepted net device mass D of the same configuration and period. Include rework and rejected-production burden.

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_pack

  • Sources:

Outputs

Product flows
Centrifugal clothes driers (finished)

The accepted complete standalone extractor of the declared configuration; excludes shipping packaging, test load and retained test water.

  • Selected flow: Centrifugal clothes driers c6fb37f3-a8e3-4178-99c5-c2dd06e2dac1

  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg

  • Amount rule: 1 kg

  • Value mode: Foreground record (foreground_record)

  • Specificity: Site-specific (site_specific)

  • Normalization basis: per 1 kg reference flow

  • Basis kind: Reference flow (reference_flow)

  • Evidence kind: Collected record (collected_record)

  • Collection protocol: cp_mass

  • Sources:

7. Allocation and Co-product Handling

rule_idApplies toRulesource_ids
subdivideshared loadsSubdivide by production lot, component state and process submeter first. Allocate only remaining measured residual using demonstrated causal equipment time/load. Do not add a whole factory meter to already charged process/test electricity.
reject_reworkaccepted denominatorRetain actual setup, rework, rejected-device and test failure burdens in Q; rejected device, scrap and packaging masses do not increase accepted denominator D. Separate configurations and net output periods.
scraprecovery/co-productsInternal returns cancel paired physical transfers only; recovery energy remains. Scrap sales do not automatically grant avoided virgin-material credits. For actual co-products first subdivide, then document physical allocation or justify another relationship with sensitivity and compatible upstream treatment.

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_airtestexternally purchased compressed airmeasurement and ledgerprovider; actual volume; temperature; absolute pressure; standard or actual basis; period; QMeter externally supplied air at documented pressure/temperature and preserve volume convention; do not duplicate in-house compressor electricity.m3each lot or matched intervalcomplete same configuration reporting period including rework and rejectsdeclared manufacturer and actual external interfaceper 1 kg reference flowcalibration; acceptance; representative assays; provider records; uncertainty
cp_massdispatchreference outputmeasurement and ledgermodel; configuration; serial number; calibrated accepted net mass; N accepted; D sum net kg; rejects; tare; dry test stateWeigh each accepted complete device on a calibrated scale excluding transport packaging and test moisture; reconcile acceptance ledger and same supplied configuration. Do not substitute rated laundry capacity.kgeach lot or matched intervalcomplete same configuration reporting period including rework and rejectsdeclared manufacturer and actual external interfaceper 1 kg reference flowcalibration; acceptance; representative assays; provider records; uncertainty
cp_materialactive processesone inputmeasurement and ledgercomponent/grade; supplier processing state; make/buy; batch; issued; returned; opening/closing stock; wet/dry; each assay; QCalibrated weighing and actual BOM/recipe issue records, linked supplier evidence; bought completed parts versus site raw inputs are disjoint.kgeach lot or matched intervalcomplete same configuration reporting period including rework and rejectsdeclared manufacturer and actual external interfaceper 1 kg reference flowcalibration; acceptance; representative assays; provider records; uncertainty
cp_energyactive processes; sharedeach utilitymeasurement and ledgermeter; period; stage; imported kWh; on-site generation; exported test regeneration; storage change; submeter allocations; residual driver; fuel kg and NCV; QMatched interval calibrated meters and bills; measure motor/test/compressor load before shared residual. Keep purchased supply versus on-site generation separate. Match fuel measurement to oven tests.MJeach lot or matched intervalcomplete same configuration reporting period including rework and rejectsdeclared manufacturer and actual external interfaceper 1 kg reference flowcalibration; acceptance; representative assays; provider records; uncertainty
cp_waterfinish; testwater balancemeasurement and ledgersupply; added water; input/test-cloth moisture; wet/dry mass; stock change; evaporation; discharge; reaction water; retained product water; paired recycle; QMeter supplied water and weigh wet/dry test cloth; sample moisture, meter effluent and account stock/return transfers. Volume-to-mass conversion uses actual temperature/density.kgeach lot or matched intervalcomplete same configuration reporting period including rework and rejectsdeclared manufacturer and actual external interfaceper 1 kg reference flowcalibration; acceptance; representative assays; provider records; uncertainty
cp_wasteactive processesone wastemeasurement and ledgerstream; receiver; gross/tare/net; water fraction; each separate metal/species assay; stocks; internal returns; QSegregated calibrated weighing with representative wet/dry and species assays plus destination/treatment receipts.kgeach lot or matched intervalcomplete same configuration reporting period including rework and rejectsdeclared manufacturer and actual external interfaceper 1 kg reference flowcalibration; acceptance; representative assays; provider records; uncertainty
cp_emissionrelease pointsone species and compartmentmeasurement and ledgerspecies; compartment; post-control concentration; air/water flow; duration; assay; capture; recovery/destruction; detection limit; uncertainty; QRepresentative post-control monitoring or documented species-specific model with flow/time and actual operating/abatement conditions; no invented balance-closing release.kgeach lot or matched intervalcomplete same configuration reporting period including rework and rejectsdeclared manufacturer and actual external interfaceper 1 kg reference flowcalibration; acceptance; representative assays; provider records; uncertainty
cp_packdispatcheach packagemeasurement and ledgermaterial; component net mass; dispatch count; reusable stock; returns; actual trips; replacement; QWeigh each packaging component, reconcile issue/return and dispatch; packaging never enters device denominator.kgeach lot or matched intervalcomplete same configuration reporting period including rework and rejectsdeclared manufacturer and actual external interfaceper 1 kg reference flowcalibration; acceptance; representative assays; provider records; uncertainty

Aggregation is per 1 kg reference flow after measuring raw period quantities. N accepted units and D sum of accepted net masses share the same configuration, BOM/test scope and period; M = D/N is only a measured mean. q_item = Q/N then q_ref = Q/D = q_item/M. No illustrative OEM weight, capacity kg, rejects or packaging may substitute for D.

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
normalizeall inventory rowsEach attributable external period quantity Q is divided by calibrated accepted net device mass D of the same configuration and period; retain the numerator physical unit and direction. Finished output is 1 kg.cp_mass; cp_material; cp_energy; cp_air; cp_water; cp_waste; cp_emission; cp_packamount per 1 kg reference flow
water_closephysical water termsSupplied water + incoming material/cloth moisture + opening stock + reaction water formed + incoming internal returns = discharged water + evaporated water + product/cloth retained water + closing stock + reaction water consumed + outgoing internal returns. Cancel only paired return terms. Investigate residual against combined measurement/sampling/allocation uncertainty; no fixed tolerance.cp_water; cp_mass; cp_material; cp_waste; cp_emissionwater residual and uncertainty
metal_closeeach contained metalFor each separate Fe, Cr, Ni, Zn, Cu and other actual element, multiply each input/product/scrap/chip/sludge/wastewater/release/stock term by its OWN matched assay and wet/dry conversion. Include reaction transformations and paired returns. Total alloy mass cannot close an elemental balance; investigate uncertainty, do not invent emissions.cp_material; cp_mass; cp_waste; cp_emissioneach elemental residual
solvent_closeeach solvent speciesOpening solvent + actual inputs + incoming internal return = retained product + closing solvent + recovered outgoing solvent + solvent in capture media + measured destruction + wastewater/non-air residue + uncaptured air release + outgoing internal return. Every term has its own species assay; paired returns cancel. Actual destruction is not air release. Investigate combined uncertainty before using residual.cp_material; cp_waste; cp_emissionspecies solvent residual
utility_residualmetered utility site periodIn identical units and intervals reconcile purchased imports + actual on-site generation + storage withdrawals against assigned fabrication/finish/motor/assembly/test/dispatch loads + unassigned shared residual + exports + storage charging and verified delivery losses. Meter factory-test regeneration separately. Negative residual requires interval/unit/calibration and combined uncertainty investigation, never clipping to zero. Allocate ONLY residual; compressor tests are included once.cp_energyreconciled residual allocation
combustionfuel speciesFuel carbon accounting can constrain fossil CO2 using actual composition, oxidation and retained carbon; it cannot establish CO, NO or NO2. Each emission requires matched technology/control concentration or a valid independent species-specific factor; total NOx convention is separately disclosed.cp_energy; cp_emissionverified species release
transfer_cancelinternal parts and returnsMatch quantity, configuration, lot, state and opening/closing work-in-progress across both sides of each internal transfer; cancel only paired transfers while retaining all actual extra processing energy, rejects and external wastes.cp_material; cp_mass; cp_water; cp_wasteno duplicate burden

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 5
Rule IDApplies toRuleSource IDs
gateforegroundInclude actual delivered-input receipt through fabrication, finish, motor make when present, assembly, balancing/acceptance, rework, rejects, residual utilities and packing before release.
make_buycomponent stateEach bought motor, drum, shaft, bearing housing, drive or control carries completed upstream production once; do not add embedded metals, resin, copper, oil or component-factory energy again. Site make instead uses actual raw inputs and stages; paired internal part transfers cancel but processing burdens remain.
factory_testtestingInclude electricity, actual consumed cloth/water, pneumatic-lock compressor load and rejects from the actual factory spin, vibration, lid-lock, braking, electrical and drain/leak plan. Model raw wet-cloth moisture and retained returns; consumer instructions demonstrate function, not a mandatory factory test recipe.thomas-instructions, ifb-inc100
downstreamlater useExclude customer laundry electricity, washing detergent/water, subsequent tumble drying, operation replacements, installation concrete and end of life from the manufacturing foreground; retain separate downstream links when study requires them. No heated drying process is inferred from the word drier.un-cpc-3-0, thomas-centri
route_auditspecific exchangesEach card is conditional on documented recipe/BOM, not a universal materials basket. Add every actual alloy, polymer, purchased part, utility, formulation constituent, packaging, treatment and emission as its own exchange. not_applicable requires absence evidence; unknown never equals zero. External transport and upstream/treatment links remain explicit.
Allocation rules · 3
Rule IDApplies toRuleSource IDs
subdivideshared loadsSubdivide by production lot, component state and process submeter first. Allocate only remaining measured residual using demonstrated causal equipment time/load. Do not add a whole factory meter to already charged process/test electricity.
reject_reworkaccepted denominatorRetain actual setup, rework, rejected-device and test failure burdens in Q; rejected device, scrap and packaging masses do not increase accepted denominator D. Separate configurations and net output periods.
scraprecovery/co-productsInternal returns cancel paired physical transfers only; recovery energy remains. Scrap sales do not automatically grant avoided virgin-material credits. For actual co-products first subdivide, then document physical allocation or justify another relationship with sensitivity and compatible upstream treatment.
Validation rules · 7
Rule IDApplies toRuleSource IDs
identityreference productRequire standalone clothes-water extraction, every qualifier, complete delivered device and correct reference link; distinguish household laundry capacity from net device mass and washing/heated-drying categories.
denominatorall inventoryRequire positive N and D from calibrated accepted same-configuration records, verify Q includes rework/reject, and q_ref = Q/D = (Q/N)/(D/N); reject package/test-water/reject mass or cross-configuration means.
buy_oncecomponent stateVerify every completed purchased motor/drum/control and embedded materials/upstream burdens once; actual site-made components activate full recipes and stages; match paired transfers.
balancesphysical water, metal and solventExecute water_close, metal_close and solvent_close for applicable records including all stocks, reactions, wet/dry and own-term assays plus paired returns. Explain residual against actual combined uncertainty, not an arbitrary universal tolerance or invented loss.
utilitiessite metersExecute utility_residual with same site interval/unit and disjoint test/process loads; imports, generation, exports/regeneration and storage must reconcile. Reject whole-factory-plus-submeter double charge and unexplained negative residual.
speciesactual emissionsCaptured material is waste, not emitted metal; separate actual species and receiving compartment. CO/NO/NO2 require their own evidence; solvent destruction and recovery differ from air release.
coveragedata packageReport accepted input, checks performed/skipped, findings and completeness; unknown UUID/provider/amount is incomplete, not zero. Conditional absence needs actual BOM/test evidence. Resolve all applicable additional exchange gaps before unqualified secondary use.
Processes and inputs/outputs · 7
Process IDProcess nameInput flowsOutput flows
fabricationBasket, drum, frame and shaft fabrication75
finishConditional surface cleaning and coating59
motor_makeConditional in-house motor production41
assemblyMechanical, electrical and safety assembly240
testFactory balancing and acceptance testing44
sharedShared factory services10
dispatchPacking and accepted extractor release41

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page