1. Scope and Applicability

This rule covers manufacture of complete machines for cleaning, sorting or grading eggs, fruit and other agricultural produce except seed, grain and dried leguminous vegetables. Separate wet washing, mechanical size/weight grading and optical defect inspection by declared configuration. Include only transfer and ejection mechanisms integral to the delivered machine. Exclude standalone produce conveyors, container cleaning/filling/packing machines, detached packing lines, separately sold parts, food cooking or extraction, farm production, packhouse operation, produce losses, yield, maintenance and end of life. The existing seed/grain/dried-legume machinery PCR explicitly excludes these products; this record supplies wet-module and optical/weighing-specific manufacturing rules. No cleaning or grading service is included.

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.metal-products-machinery-and-equipment.special-purpose-machinery.agricultural-produce-cleaning-sorting-and-grading-machinery
classification_refsCPC 3.0 44127; category context, not an accepted mapping
covered_productsComplete egg, fruit and other non-seed/grain/dried-legume produce cleaning, sorting and grading machines
excluded_productsSeed/grain/dried-legume equipment; standalone conveyors and packing machines; produce products and services
representative_productOne accepted empty configured wet washer or mechanical/optical grader
production_routeDeclared purchased stock and components; actual site fabrication, joining, preparation, assembly, control integration and factory acceptance
market_stateNew, drained complete accepted machine at factory gate; packaging separately inventoried

3. Reference Flow

FieldValue
WhatProvide the declared produce-cleaning, sorting or grading machinery function
How much1 kg of an accepted complete configured machine using measured net mass M
How wellMeet declared drawing, food-contact construction specification and factory functional acceptance. Washer: leakage and circulation checks; grader: reference-size or calibrated-weight challenges; optical configuration: documented labelled defect samples and interlocks. Actual acceptance criteria must be supplied; no universal accuracy or throughput threshold.
How long or cycleOne manufacturing delivery; no assumed operating life or kilograms of produce processed
reference_flow_linkfinished_machine
FieldValue
Reference amount1
Reference product flowMachines for cleaning, sorting or grading eggs, fruits or other agricultural produce 36b20b75-5f43-46ab-9e96-d8018f4c75f4
Reference flow propertyMass 93a60a56-a3c8-11da-a746-0800200b9a66
Reference unit groupUnits of mass 93a60a57-a4c8-11da-a746-0800200c9a66
Reference unitkg
Required qualifiersmodel, serial/lot, produce family; wash/size/weight/optical function; lane and installed module configuration; food-contact grades and finish; rated capacity as descriptive metadata only; empty/drained tanks; installed drives, pumps, controls, integrated conveyors and guards; retained lubricant; M; site and period; supplier gates and stage coverage

Do not infer a food-contact certification, resin, machine mass, lifetime or factory consumption from manufacturer examples. Equal kilogram reference flows do not establish functional equivalence across washer and grader configurations.

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
reference_massreference productMass 93a60a56-a3c8-11da-a746-0800200b9a66kgM = accepted net mass of one complete machine of the same configuration in kg; collect using cp_mass.
energy_unitselectricity rowsNet calorific value 93a60a56-a3c8-11da-a746-0800200c9a66MJPreserve the meter unit; convert kWh to MJ using exactly 1 kWh = 3.6 MJ. Do not interpret the electricity property name as a combustion inventory.
volume_unitsgroundwater rowsVolume 93a60a56-a3c8-22da-a746-0800200c9a66m3Retain measured volume and its conditions; do not invent gas density, water density or calorific value to switch to mass or energy.

5. System Boundary

Boundary Abstraction

FieldValue
declared_starting_conditionMaterials and configured components received at declared supplier gates, with no implicit upstream steelmaking or component fabrication in foreground
starting_condition_roleManufacturing input boundary for an accepted complete machine
product_classification_scopeConfigured agricultural produce cleaning and grading machines within CPC 44127 context
recursive_input_ruleA purchased complete machine used as an input is a separately declared upstream product. Do not recursively regenerate this category; distinguish new production from refurbishment.
upstream_dataset_requirementLink input-specific upstream datasets matching material, finished-component gate, geography, voltage and treatment state. Missing links remain disclosed coverage gaps.
disclosureReport foreground factory stages, outsourced operations, component content, incoming transport coverage, protective packaging gate, capital-equipment policy and every exclusion; no complete cradle-to-gate claim without verified upstream and logistics closure.
rule_idapplies_torulesource_ids
manufacturing_gateforegroundInclude every actual operation and attributable rework from declared received inputs through factory acceptance; distinguish purchased parts from site fabrication to prevent duplication. Use documented route records.
conditional_finishfinishingActivate only documented finishing operations and chemical recipes. Manufacturer examples establish possible routes, not universal requirements or recipes.sormac-sw50-2026
exclude_fieldfarm_useKeep produce cultivation, packhouse operation, runtime water and sanitation, rejected produce, food yield and machine disposal outside this manufacturing inventory. No grading service is included.

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
formingStock cutting, forming and machiningconditionalOnly onsite fabricated parts; purchased finished parts replace stock inputsforeground manufacturingper 1 kg reference flow; collected per one accepted finished machine
joiningHygienic fabrication joining and dressingconditionalOnly the actual onsite joining route; no universal welding requirementforeground manufacturingper 1 kg reference flow; collected per one accepted finished machine
wet_surfaceRoute-specific aqueous cleaning and passivationconditionalOnly documented aqueous preparation and its actual chemical recipeforeground manufacturingper 1 kg reference flow; collected per one accepted finished machine
assemblyMechanical and wet-module assemblyrequiredEvery complete accepted machine; activate installed components onlyforeground manufacturingper 1 kg reference flow; collected per one accepted finished machine
controlsWeighing and optical-control integrationconditionalOnly configurations containing weighing, optical inspection or PLC hardwareforeground manufacturingper 1 kg reference flow; collected per one accepted finished machine
acceptanceFactory functional acceptance and net-mass determinationrequiredEvery complete accepted machine; water exchanges only for documented wet testsforeground manufacturingper 1 kg reference flow; collected per one accepted finished machine
packagingShipment protection at factory gateconditionalOnly protection inside declared delivery gate; otherwise disclose exclusionforeground manufacturingper 1 kg reference flow; collected per one accepted finished machine

Process records are separate contributors to one final accepted output, not seven separately traded reference products. Retain traceable internal-part transfer and bill-of-material records; internal transfers cancel within this foreground and do not receive duplicated upstream burdens. The cards below are explicit route-conditioned exchanges. Add each actual additional part, chemical, fuel, packaging piece, wastewater stream or measured elementary substance as its own identified row; absence of a card is not a cut-off permission. For outsourced finishing, replace site chemistry and energy with the exact purchased service or finished-part record and disclose its coverage.

Process: Stock cutting, forming and machining (forming)

Inputs

Product flows
Cold-rolled stainless steel sheet (stainless_sheet)

Only stock actually issued for food-contact basin, deck, pipe or frame fabrication. Record alloy grade, thickness, food-contact specification and finish. A further-worked flat product does not establish ordinary cold-rolled sheet identity.

  • Selected flow: Cold-rolled stainless steel sheet
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_forming.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_forming
  • Sources: sormac-sw50-2026
Alternating current (forming_electricity)

Meter this operation and attributable tools, extraction or test rigs without overlapping factory meters. UUID only for grid-average user-side 1–35 kV purchased supply. Other voltage, origin or supplier gate requires another verified identity; internal transformed electricity is not another purchase.

  • Selected flow: Alternating current 3d76981f-964a-4865-b588-0e067a2a1163
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_forming.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_forming

Outputs

Waste flows
Post-industrial stainless steel sheet offcut (stainless_offcut)

Segregated clean sheet trim exported untreated. Weigh by alloy grade and identify receiver; generic steel scrap does not establish stainless composition. Internal reuse cancels and oily swarf requires a separate characterized row.

  • Selected flow: Post-industrial stainless steel sheet offcut
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_forming.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_forming

Process: Hygienic fabrication joining and dressing (joining)

Inputs

Product flows
Solid stainless steel welding wire (stainless_wire)

Only when the site uses this actual welding route. Record alloy designation and consumed spool mass; carbon-steel flux-cored wire is incompatible.

  • Selected flow: Solid stainless steel welding wire
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_joining.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_joining
Pure argon welding shielding gas (argon)

Only documented pure-argon supply; determine consumed mass from cylinder issue and return. Carbon dioxide shielding gas or composition-unspecified welding gas is not substituted.

  • Selected flow: Pure argon welding shielding gas
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_joining.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_joining
Alternating current (joining_electricity)

Meter this operation and attributable tools, extraction or test rigs without overlapping factory meters. UUID only for grid-average user-side 1–35 kV purchased supply. Other voltage, origin or supplier gate requires another verified identity; internal transformed electricity is not another purchase.

  • Selected flow: Alternating current 3d76981f-964a-4865-b588-0e067a2a1163
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_joining.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_joining

Process: Route-specific aqueous cleaning and passivation (wet_surface)

Inputs

Product flows
Citric acid aqueous passivation reagent, concentration declared (citric_acid)

Only a site-confirmed citric-acid passivation recipe. Record supplied concentration, hydration state and makeup mass. Manufacturer stainless construction does not require chemical passivation or establish a recipe; nitric acid, alkali and formulated cleaner each need their own actual row if used.

  • Selected flow: Citric acid aqueous passivation reagent, concentration declared
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_wet_surface.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_wet_surface
Process Water (surface_water)

Treated purchased process water for actual cleaning or rinsing. Collect supplied mass; preserve treatment and supplier gate. Supplier water extraction is not repeated as a foreground resource.

  • Selected flow: Process Water 94a04f7e-2d5c-41f0-b182-d54a3b373a02
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_wet_surface.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_wet_surface
Alternating current (wet_surface_electricity)

Meter this operation and attributable tools, extraction or test rigs without overlapping factory meters. UUID only for grid-average user-side 1–35 kV purchased supply. Other voltage, origin or supplier gate requires another verified identity; internal transformed electricity is not another purchase.

  • Selected flow: Alternating current 3d76981f-964a-4865-b588-0e067a2a1163
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_wet_surface.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_wet_surface

Outputs

Waste flows
Spent aqueous citric-acid passivation solution (passivation_effluent)

Only this segregated liquid stream if exported for treatment. Weigh actual solution, measure pH and composition and record receiver. This waste transfer is not an elementary water emission.

  • Selected flow: Spent aqueous citric-acid passivation solution
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_wet_surface.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_wet_surface

Process: Mechanical and wet-module assembly (assembly)

Inputs

Product flows
Electric motor (motor)

Each installed purchased motor for a conveyor, drive or washing module; record model and net component mass. Use identity only, never the database expert-estimated quantity; exclude motors already included in purchased pump modules.

  • Selected flow: Electric motor 014f80a3-c257-425b-9b75-3e5a18573695
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_assembly.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_assembly
Pump (pump)

One purchased pump type per record, only if installed in the wet configuration. Declare centrifugal water-circulation route, casing, motor inclusion and mass; no pumping service or upstream extraction is represented.

  • Selected flow: Pump bbd91be4-dc00-44c2-8bc1-f67ee79174a7
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_assembly.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_assembly
  • Sources: sormac-sw50-2026
Food-contact polyurethane conveyor belt (conveyor_belt)

Only when supplier BOM confirms polyurethane finished belt and its contact specification. A polymer film, leather or rubber belt is not this finished component; generic food-grade plastic evidence alone does not establish polyurethane.

  • Selected flow: Food-contact polyurethane conveyor belt
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_assembly.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_assembly
Polypropylene fruit carrier roller (carrier_roller)

Only supplier-confirmed polypropylene roller; weigh finished rollers and record food-contact grade. Do not infer resin from blue colour or manufacturer polymer wording.

  • Selected flow: Polypropylene fruit carrier roller
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_assembly.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_assembly
Stainless steel bolt (stainless_bolt)

Only installed bolts with declared alloy grade, dimensions and mass. Generic steel fasteners or bearing identities are not equivalent; nuts, bearings and guards require separate BOM rows.

  • Selected flow: Stainless steel bolt
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_assembly.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_assembly
Alternating current (assembly_electricity)

Meter this operation and attributable tools, extraction or test rigs without overlapping factory meters. UUID only for grid-average user-side 1–35 kV purchased supply. Other voltage, origin or supplier gate requires another verified identity; internal transformed electricity is not another purchase.

  • Selected flow: Alternating current 3d76981f-964a-4865-b588-0e067a2a1163
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_assembly.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_assembly

Process: Weighing and optical-control integration (controls)

Inputs

Product flows
Industrial machine-vision camera (camera)

Only installed optical inspection hardware; record model, spectral channels, housing, lenses included and net mass. A still-image digital consumer camera is not a verified industrial camera. Optical lighting and computers require individual records if installed.

  • Selected flow: Industrial machine-vision camera
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_controls.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_controls
  • Sources: tomra-apples-historical
Load cell (loadcell)

Only installed weighing force transducer. Record calibration class, model and measured component mass. Reject a candidate with ecosystem-toxicity reference property; do not transfer its assumed unit count or aggregated quantity. Use the separately verified generic purchased-component mass identity with the actual strain-gauge model declared.

  • Selected flow: Load cell 5f7f1e13-97fb-48bc-99db-4b3a6736610e
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_controls.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_controls
Programmable logic controller (plc)

Only an actual purchased PLC hardware component supplied at a China plant gate matching this identity; record model, I/O configuration and mass. Other supply locations or generic control cabinets require separately verified identity; do not count cabinet contents twice.

  • Selected flow: Programmable logic controller 5b817eb4-cab3-4fed-87c9-457d66d0bb19
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_controls.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_controls
Alternating current (controls_electricity)

Meter this operation and attributable tools, extraction or test rigs without overlapping factory meters. UUID only for grid-average user-side 1–35 kV purchased supply. Other voltage, origin or supplier gate requires another verified identity; internal transformed electricity is not another purchase.

  • Selected flow: Alternating current 3d76981f-964a-4865-b588-0e067a2a1163
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_controls.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_controls

Process: Factory functional acceptance and net-mass determination (acceptance)

Inputs

Product flows
Process Water (test_water)

Purchased treated process water consumed only in documented factory wet-function tests. Collect makeup and unrecovered losses, not repeated circulation or catalogue tank capacity. Runtime washing at a packhouse is excluded.

  • Selected flow: Process Water 94a04f7e-2d5c-41f0-b182-d54a3b373a02
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_acceptance.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_acceptance
  • Sources: sormac-sw50-2026
Alternating current (acceptance_electricity)

Meter this operation and attributable tools, extraction or test rigs without overlapping factory meters. UUID only for grid-average user-side 1–35 kV purchased supply. Other voltage, origin or supplier gate requires another verified identity; internal transformed electricity is not another purchase.

  • Selected flow: Alternating current 3d76981f-964a-4865-b588-0e067a2a1163
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_acceptance.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_acceptance
Elementary flows
ground water (well_water)

Only onsite groundwater directly abstracted for manufacturing acceptance tests. Meter m3, well and country; Resources / Resources from water / Renewable material resources from water. No scarcity class asserted. Never count the same water as purchased process water.

  • Selected flow: ground water 4f462198-40cd-4184-8733-86648a20dc3f
  • Flow property / unit: Volume 93a60a56-a3c8-22da-a746-0800200c9a66 / m3
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_acceptance.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_acceptance

Outputs

Product flows
Machines for cleaning, sorting or grading eggs, fruits or other agricultural produce (finished_machine)

One kilogram is a normalized slice of a complete accepted configured machine. Tanks are empty and drained; no produce payload or trial water is included in M. Retained lubricant, declared integrated transfer mechanism, guards and installed controls are included; detachable packing lines and shipment packaging are excluded.

  • Selected flow: Machines for cleaning, sorting or grading eggs, fruits or other agricultural produce 36b20b75-5f43-46ab-9e96-d8018f4c75f4
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: 1 kg
  • Value mode: fixed_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_mass
Waste flows
Aqueous factory wet-test wastewater (test_effluent)

Only discharged to offsite treatment as this single segregated wastewater. Measure mass and actual suspended or dissolved constituents and receiving treatment. Onsite environmental discharge needs separate measured substances and receiving media; do not invent nutrient or organic emissions from operating brochures.

  • Selected flow: Aqueous factory wet-test wastewater
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_acceptance.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_acceptance

Process: Shipment protection at factory gate (packaging)

Inputs

Product flows
Polyethylene film (film)

Only actual polyethylene shipment film; weigh installed packing and exported trim separately. Packaging inventory is separate from accepted net mass.

  • Selected flow: Polyethylene film e64eb06c-6dc9-45f1-b003-3dc6c44b27e2
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_packaging.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_packaging
Solid wood transport pallet (wood_pallet)

Only actual pallet supplied with the machine. Record wood species, treatment, reusable status and mass; do not infer a generic pallet material or recycled content.

  • Selected flow: Solid wood transport pallet
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_packaging.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_packaging
Alternating current (packaging_electricity)

Meter this operation and attributable tools, extraction or test rigs without overlapping factory meters. UUID only for grid-average user-side 1–35 kV purchased supply. Other voltage, origin or supplier gate requires another verified identity; internal transformed electricity is not another purchase.

  • Selected flow: Alternating current 3d76981f-964a-4865-b588-0e067a2a1163
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_packaging.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_packaging

7. Allocation and Co-product Handling

rule_idapplies_torulesource_ids
direct_attributionshared_operationsUse job tickets and submetering before allocation. Where a common meter remains, require a measured causal driver such as machine-hours for the identified operation, with all participating jobs and idle load disclosed; divide the attributable quantity by accepted units of the same configuration before mass normalization.ghg-product-allocation-2011
coproduct_decisionsaleable_outputsDo not assume scrap is a co-product. Disclose destination and legal/product status. If multiple saleable co-products actually occur, seek subdivision; justify a physical relation or, when unavailable, documented economic/other allocation with sensitivity. No universal mass share or avoided-steel credit is prescribed.ghg-product-allocation-2011
rework_scrapmanufacturing_lossesRetain rework and rejected-unit burdens attributable to the accepted reporting batch. Record recovered internal material once and exported wastes separately. Disclose upstream recycled-content method and any downstream treatment separately to prevent double credits.

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_massacceptanceaccepted net massweighingmodel; configuration; serial number; accepted net mass MWeigh the accepted complete machine on a calibrated scale, excluding transport packaging; reconcile the same configuration and acceptance record.kgeach acceptancecomplete reporting batchsame model and configurationaccepted net mass per machinecalibration, weighing and signed acceptance records
cp_formingformingStock cutting, forming and machiningmeter_and_issue_recordsjob and configuration; accepted unit count; each row-specific issued/returned amount and original unit; constituent/grade; meter readings; allocation driver; waste destination; route conditionsFor each atomic row, use calibrated meters, weighed issue/returns, supplier receipts and disposal tickets. Preserve property: kg for mass, MJ from electricity meters, m3 for directly abstracted groundwater. Do not convert purchased-water mass to volume without measured density and conditions. Reconcile stage utility totals with the factory bill, and component/retained-fluid inclusion with the net-mass record.row-specific kg, MJ, m3each job and meter intervalcomplete same-configuration batch in reporting period; disclose seasonality and mixed linesdeclared factory, outsourced and purchased gatesattributable row amount / accepted machines of the same configurationcalibration, supplier composition, job, allocation and disposal evidence
cp_joiningjoiningHygienic fabrication joining and dressingmeter_and_issue_recordsjob and configuration; accepted unit count; each row-specific issued/returned amount and original unit; constituent/grade; meter readings; allocation driver; waste destination; route conditionsFor each atomic row, use calibrated meters, weighed issue/returns, supplier receipts and disposal tickets. Preserve property: kg for mass, MJ from electricity meters, m3 for directly abstracted groundwater. Do not convert purchased-water mass to volume without measured density and conditions. Reconcile stage utility totals with the factory bill, and component/retained-fluid inclusion with the net-mass record.row-specific kg, MJ, m3each job and meter intervalcomplete same-configuration batch in reporting period; disclose seasonality and mixed linesdeclared factory, outsourced and purchased gatesattributable row amount / accepted machines of the same configurationcalibration, supplier composition, job, allocation and disposal evidence
cp_wet_surfacewet_surfaceRoute-specific aqueous cleaning and passivationmeter_and_issue_recordsjob and configuration; accepted unit count; each row-specific issued/returned amount and original unit; constituent/grade; meter readings; allocation driver; waste destination; route conditionsFor each atomic row, use calibrated meters, weighed issue/returns, supplier receipts and disposal tickets. Preserve property: kg for mass, MJ from electricity meters, m3 for directly abstracted groundwater. Do not convert purchased-water mass to volume without measured density and conditions. Reconcile stage utility totals with the factory bill, and component/retained-fluid inclusion with the net-mass record.row-specific kg, MJ, m3each job and meter intervalcomplete same-configuration batch in reporting period; disclose seasonality and mixed linesdeclared factory, outsourced and purchased gatesattributable row amount / accepted machines of the same configurationcalibration, supplier composition, job, allocation and disposal evidence
cp_assemblyassemblyMechanical and wet-module assemblymeter_and_issue_recordsjob and configuration; accepted unit count; each row-specific issued/returned amount and original unit; constituent/grade; meter readings; allocation driver; waste destination; route conditionsFor each atomic row, use calibrated meters, weighed issue/returns, supplier receipts and disposal tickets. Preserve property: kg for mass, MJ from electricity meters, m3 for directly abstracted groundwater. Do not convert purchased-water mass to volume without measured density and conditions. Reconcile stage utility totals with the factory bill, and component/retained-fluid inclusion with the net-mass record.row-specific kg, MJ, m3each job and meter intervalcomplete same-configuration batch in reporting period; disclose seasonality and mixed linesdeclared factory, outsourced and purchased gatesattributable row amount / accepted machines of the same configurationcalibration, supplier composition, job, allocation and disposal evidence
cp_controlscontrolsWeighing and optical-control integrationmeter_and_issue_recordsjob and configuration; accepted unit count; each row-specific issued/returned amount and original unit; constituent/grade; meter readings; allocation driver; waste destination; route conditionsFor each atomic row, use calibrated meters, weighed issue/returns, supplier receipts and disposal tickets. Preserve property: kg for mass, MJ from electricity meters, m3 for directly abstracted groundwater. Do not convert purchased-water mass to volume without measured density and conditions. Reconcile stage utility totals with the factory bill, and component/retained-fluid inclusion with the net-mass record.row-specific kg, MJ, m3each job and meter intervalcomplete same-configuration batch in reporting period; disclose seasonality and mixed linesdeclared factory, outsourced and purchased gatesattributable row amount / accepted machines of the same configurationcalibration, supplier composition, job, allocation and disposal evidence
cp_acceptanceacceptanceFactory functional acceptance and net-mass determinationmeter_and_issue_recordsjob and configuration; accepted unit count; each row-specific issued/returned amount and original unit; constituent/grade; meter readings; allocation driver; waste destination; route conditionsFor each atomic row, use calibrated meters, weighed issue/returns, supplier receipts and disposal tickets. Preserve property: kg for mass, MJ from electricity meters, m3 for directly abstracted groundwater. Do not convert purchased-water mass to volume without measured density and conditions. Reconcile stage utility totals with the factory bill, and component/retained-fluid inclusion with the net-mass record.row-specific kg, MJ, m3each job and meter intervalcomplete same-configuration batch in reporting period; disclose seasonality and mixed linesdeclared factory, outsourced and purchased gatesattributable row amount / accepted machines of the same configurationcalibration, supplier composition, job, allocation and disposal evidence
cp_packagingpackagingShipment protection at factory gatemeter_and_issue_recordsjob and configuration; accepted unit count; each row-specific issued/returned amount and original unit; constituent/grade; meter readings; allocation driver; waste destination; route conditionsFor each atomic row, use calibrated meters, weighed issue/returns, supplier receipts and disposal tickets. Preserve property: kg for mass, MJ from electricity meters, m3 for directly abstracted groundwater. Do not convert purchased-water mass to volume without measured density and conditions. Reconcile stage utility totals with the factory bill, and component/retained-fluid inclusion with the net-mass record.row-specific kg, MJ, m3each job and meter intervalcomplete same-configuration batch in reporting period; disclose seasonality and mixed linesdeclared factory, outsourced and purchased gatesattributable row amount / accepted machines of the same configurationcalibration, supplier composition, job, allocation and disposal evidence

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
normalize_massall inventory rowsq_ref = q_item / M; q_item = exchange amount per one accepted finished machine; q_ref = exchange amount per 1 kg reference flow.q_item; M; cp_massq_ref

The finished_machine output is fixed at 1 kg and is not divided again. Apply the conversion to each other applicable row using the same configuration and batch; quantity numerator units remain unchanged. Mixed configurations must be separated, not averaged by count with a catalogue mass.

Data Quality Requirements

requirement_idApplies toRequirementEvidence
configuration_traceall rowsTrace every input to installed BOM, route and accepted unit; supplier finished parts do not also receive raw-stock burdens. Disclose remaining components as missing coverage until separate atomic records are added.drawings, BOM, supplier receipts
basis_qualitycp_massM must be positive measured net mass, with the same delivered configuration, fluid state and acceptance gate as all collected exchanges.calibration and weighing records
coverage_qualityall processesDocument full batch temporal coverage, meter overlap, rejects, rework, stock changes, outsourced stages and unmeasured emissions. A missing record is unknown, not zero or not_applicable.ledger, coverage matrix and measurement uncertainty
chemistry_qualitywet_surface; acceptanceVerify recipe, concentration and SDS for each supplied formulated chemical; characterize each outgoing waste stream and identify treatment separately from environmental emissions.recipe, SDS, analyses and transfer tickets

9. Validation Rules

rule_idapplies_torulesource_ids
validate_referencereferenceReject missing qualifiers, payload/gross mass substitution, non-positive M or mismatch between configuration, cp_mass and finished_machine. Require 1 kg output and explicit normalize_mass on every non-reference applicable row.
validate_atomicinventoryRequire one physical exchange per row, verified public identity when supplied, correct property/unit, localized display and medium. Unresolved UUIDs do not authorize proxy substitution or mixed rows.
validate_balancecoverageReconcile installed mass, stock, waste, retained fluids and purchased parts using the actual BOM. Reconcile utilities by stage; internal transfers cancel. Explain differences against recorded measurement uncertainty, without a fabricated numerical tolerance.
validate_completenessdatasetCheck every conditional stage against route evidence. Require missing chemicals, parts, test media and actual emissions to be split and collected before claiming a complete inventory; prohibit cradle-to-gate or service comparisons while upstream or functional coverage is incomplete.
validate_allocationshared_operationsRequire complete driver records and justification for allocation and scrap treatment; document sensitivity where another defensible allocation may change results.ghg-product-allocation-2011

10. Published Dataset Profile

FieldValue
dataset_roleManufacturing foreground process for a configured accepted machine
downstream_usesecondary_dataset; background_dataset
allowed_useInput to a declared machinery supply model with identical configuration and disclosed upstream coverage
excluded_usePackhouse runtime consumption, produce yield, grade recovery, whole-life cleaning service or comparisons across functions without additional functional modelling
required_metadataModel, configuration, empty state, M, retained fluids, manufacturer/site, reporting period, process route, voltage/geography, supplier gates, transport/packaging scope and allocation
required_quality_disclosureMeasured versus estimated quantities; unresolved identities; unmeasured emissions and components; upstream linkage completeness; uncertainty, data age and configuration limitations
update_triggerChanged mechanism, capacity, BOM, coating chemistry, supplied component, energy mix, acceptance specification or mass protocol

11. Data Sources

Source idTypeReferenceUsed for
sormac-sw50-2026handbookSormac, Spiral washer SW-50 range, SW-50-EN2026/1, PDF pp.1–2 (unnumbered), Product specification, Scope of delivery, Operating principle and Hygienic piping. https://static.sormac.com/a9/4a/a94a0f281b5cfb253829a581a8f035052fdd450a.pdfWet-module and stainless/unspecified food-grade plastic configuration; options vary. Operating water capacity is not manufacturing test consumption.
tomra-apples-historicalhandbookTOMRA, Spotlight Apples, undated brochure, PDF creation metadata 2022-06-08, PDF p.5 (unnumbered), Inspecting, sorting, grading – and protecting. https://www.tomra.com/-/media/project/tomra/tomra/solutions/food/in-the-spotlight-pdf-files/tomra-segment_article-apples-en.pdfHistorical 5S/Spectrim apple grading and contact-area configuration only; no current availability, lifetime, resin chemistry or factory intensity assertion.
moba-omnia-ethandbookMoba, Omnia ET, official product page, Highlights and Detection sections. https://moba.net/products-solutions/omnia-et/Egg individual handling, weighing and defect detection; optional modules do not prescribe all-machine BOM.
ghg-product-allocation-2011official_guidanceWRI/WBCSD, Product Life Cycle Accounting and Reporting Standard (2011), chapter 9, printed p.63 / PDF p.65, tables 9.1–9.2. https://ghgprotocol.org/sites/default/files/standards/Product-Life-Cycle-Accounting-Reporting-Standard_041613.pdfHistorical allocation hierarchy only; no current comprehensive standard conformance assertion.

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 3
Rule IDApplies toRuleSource IDs
manufacturing_gateforegroundInclude every actual operation and attributable rework from declared received inputs through factory acceptance; distinguish purchased parts from site fabrication to prevent duplication. Use documented route records.
conditional_finishfinishingActivate only documented finishing operations and chemical recipes. Manufacturer examples establish possible routes, not universal requirements or recipes.sormac-sw50-2026
exclude_fieldfarm_useKeep produce cultivation, packhouse operation, runtime water and sanitation, rejected produce, food yield and machine disposal outside this manufacturing inventory. No grading service is included.
Allocation rules · 3
Rule IDApplies toRuleSource IDs
direct_attributionshared_operationsUse job tickets and submetering before allocation. Where a common meter remains, require a measured causal driver such as machine-hours for the identified operation, with all participating jobs and idle load disclosed; divide the attributable quantity by accepted units of the same configuration before mass normalization.ghg-product-allocation-2011
coproduct_decisionsaleable_outputsDo not assume scrap is a co-product. Disclose destination and legal/product status. If multiple saleable co-products actually occur, seek subdivision; justify a physical relation or, when unavailable, documented economic/other allocation with sensitivity. No universal mass share or avoided-steel credit is prescribed.ghg-product-allocation-2011
rework_scrapmanufacturing_lossesRetain rework and rejected-unit burdens attributable to the accepted reporting batch. Record recovered internal material once and exported wastes separately. Disclose upstream recycled-content method and any downstream treatment separately to prevent double credits.
Validation rules · 5
Rule IDApplies toRuleSource IDs
validate_referencereferenceReject missing qualifiers, payload/gross mass substitution, non-positive M or mismatch between configuration, cp_mass and finished_machine. Require 1 kg output and explicit normalize_mass on every non-reference applicable row.
validate_atomicinventoryRequire one physical exchange per row, verified public identity when supplied, correct property/unit, localized display and medium. Unresolved UUIDs do not authorize proxy substitution or mixed rows.
validate_balancecoverageReconcile installed mass, stock, waste, retained fluids and purchased parts using the actual BOM. Reconcile utilities by stage; internal transfers cancel. Explain differences against recorded measurement uncertainty, without a fabricated numerical tolerance.
validate_completenessdatasetCheck every conditional stage against route evidence. Require missing chemicals, parts, test media and actual emissions to be split and collected before claiming a complete inventory; prohibit cradle-to-gate or service comparisons while upstream or functional coverage is incomplete.
validate_allocationshared_operationsRequire complete driver records and justification for allocation and scrap treatment; document sensitivity where another defensible allocation may change results.ghg-product-allocation-2011
Processes and inputs/outputs · 7
Process IDProcess nameInput flowsOutput flows
formingStock cutting, forming and machining21
joiningHygienic fabrication joining and dressing30
wet_surfaceRoute-specific aqueous cleaning and passivation31
assemblyMechanical and wet-module assembly60
controlsWeighing and optical-control integration40
acceptanceFactory functional acceptance and net-mass determination32
packagingShipment protection at factory gate30

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.