TianGong PCR

Multi-dwelling and community residential building delivery

Lifecycle status
Candidate
Content maturity
Authored methodology
Current version
0.1.0Last updated
Readiness
Review required

Methodology and translation states come from the source record; publishing this website does not change their review status.

Content languages

zh-CN · Aligned
Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:53112 · exact

Source

1. Scope and Applicability

The product is the physical residential building delivered at its actual site: buildings with three or more dwellings, and residential buildings for communities such as elderly/student residences, workers’ hostels, orphanages and homeless shelters. Community residences are included by their residential function, not by inventing three self-contained dwellings. Hospitals, hotels, construction services and loose building components are outside this category; mixed uses require documented applicability and separately identified scope. No particular structure, height, lift, kitchen or care equipment is universally mandatory.

The foreground covers actual site preparation, foundation/structure, envelope, declared fixed installations and fit-out, site logistics, testing and acceptance. Complete, shell-and-core and other delivery states must be distinguished. Whole-building accounting includes common circulation, stairs, shared cores, actual central services and community spaces delivered in the contract. Upstream construction-product manufacture is separately linked; delivery transport and site construction remain distinguishable. Operational utilities, actual later maintenance/replacements, demolition and final waste destinations are excluded later stages, not a hidden assumed lifetime. A construction inventory alone is neither a complete cradle-to-gate nor a whole-life assessment.

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.constructions-and-construction-services.constructions.multi-dwelling-and-community-building-delivery
classification_refsCPC 3.0 53112
covered_productsDelivered multi-dwelling buildings and community residential buildings, with all declared private/common fixed works
excluded_productsOne-/two-dwelling houses; non-residential institutions; hotels; mobile accommodation; construction/renovation services; loose materials and equipment
representative_productOne surveyed residential building with its actual dwelling/room/capacity schedule and common facilities
production_routeActual masonry, concrete, steel, timber or mixed assembly; site and prefabrication gates explicitly recorded; no generic recipe
market_stateImmovable residential asset at signed physical delivery condition

3. Reference Flow

FieldValue
WhatProvide the delivered physical building for its documented residential/community use
How muchOne whole building; actual dwelling/room count, resident capacity, gross internal floor area, private residential area, common circulation/facility area, footprint, storeys and dimensions
How wellAs-built structural/envelope specification, private/common installations, accessibility/fire/service performance specified by the project and documented inspection; no inferred legal approval
How long or cycleOne construction-and-handover cycle; no default service life or dwelling-years. Later service comparisons require evidence-backed periods and scenarios
reference_flow_linkreference_building
FieldValue
Reference amount1
Reference product flowCompleted multi-dwelling or community residential building
Reference flow propertyNumber of items 01846770-4cfe-4a25-8ad9-919d8d378345
Reference unit groupUnits of items 5beb6eed-33a9-47b8-9ede-1dfe8f679159
Reference unititem
Required qualifiersproject/site; residential use; dwelling/room count and actual capacity; survey method and area breakdown; structure/foundation and ground conditions; height/storeys; as-built materials; private/common delivery completeness; central plant capacities and served zones; accessibility/fire acceptance records; shared basement/site attribution; dates; upstream and A4/A5 coverage; excluded later stages

item denotes the public Item(s) unit: one building, not one apartment or resident. Required qualifiers must be present in the actual dataset. Building area is surveyed descriptive geometry, not an assumed conversion of housing function. The reference UUID is unresolved because the named public category uses Mass and no building-specific mass-to-count evidence is established. Do not rewrite that public property or invent a building mass.

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
reference_countreference productNumber of items 01846770-4cfe-4a25-8ad9-919d8d378345itemUse cp_handover for one actual accepted whole building. All exchanges use the same declared reference flow; apartment counts never multiply common structure burdens.
geometryreference productArea 93a60a56-a3c8-19da-a746-0800200c9a66m2Collect cp_geometry survey definitions and private/common/service area breakdown. Reconcile included floor plates without double-counting corridors; keep footprint, gross internal and usable areas distinct. Area reporting is supplementary and cannot imply equal dwelling function.
energylv_electricity; mv_electricity; site_dieselNet calorific value 93a60a56-a3c8-11da-a746-0800200c9a66MJPreserve actual Net calorific value property and reference energy unit. Metered electricity kWh is multiplied by 3.6 to MJ; fuel requires actual batch net calorific value and measured mass/density. No default fuel factor.
physical_quantitiesall inventory rowsActual row reference propertyrow unitRetain each measured mass, area, volume, item or transport quantity in its real property. Conversions need material-specific measurements, thickness/density and physical-state evidence; volume of soil or washwater is not abstracted-resource water.

5. System Boundary

Boundary Abstraction

FieldValue
declared_starting_conditionRecorded initial site and supplied product gates, including actual enabling works and retained structures
starting_condition_roleforeground_start
product_classification_scopeMulti-dwelling and community residential physical building entity
recursive_input_ruleA retained/reused same-category structure is a separately identified existing asset input with declared burdens and condition, not a second new whole-building output
upstream_dataset_requirementLink every actual supplied atomic material/component to unit/state/gate-compatible manufacturing evidence; identify missing supplier/background coverage
disclosureSeparate upstream manufacture, inbound transport, site construction, initial demolition if any, waste routing and excluded use/maintenance/final demolition; declare common/site works attribution
rule_idapplies_torulesource_ids
boundary_deliveryall inventory rowsAccount for the delivered whole entity and every actually occurring exchange in shell, core, private and communal works. These conditional rows are minimum inspection prompts, not a closed universal bill of materials. Add separate atomic rows for actual roof coverings, fittings, stairs, external works, heat/cooling plant, community kitchens, security/fire systems and their specific materials when present. No alternative is silently substituted or omitted.jrc-levels-boq-2021; rics-wlca-2024
boundary_stagesdatasetManufacture of installed equipment/materials is upstream; fitting, lifting, site conditioning, pressure tests and commissioning are foreground. Operation, real future maintenance/renewal and final dismantling are separately scoped later stages. Initial site demolition and clearance are construction-enabling activities when actually undertaken, not future demolition. Disclose missing A1–A3/A4/A5 coverage.rics-wlca-2024
boundary_commoncommon_facilitiesInclude actual shared stairs, cores, plant rooms and residential-community facilities in the whole-building ledger, even if separately contracted. Identify central systems and served zones. For linked buildings with shared basements, establish a combined assessment ledger before attributing building shares; disclose the parent assessment and conservation. Do not hide all shared works outside private apartment area.rics-wlca-2024
boundary_releasessite_utilitiesRecord technical supplied water separately from natural resource intake; track dewatering returns by destination and chemistry. Washout liquid/solids are not freshwater. Inventory actual direct exhaust/dust/discharges only with release evidence; assess construction noise using actual equipment/receptor/time evidence and disclose characterization gaps without inventing a mass flow.epa-concrete-washout-2012; epa-construction-dust-2010

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
groundworksSite preparation and groundworksrequiredInspect actual work-package completeness; each exchange is conditional on its real occurrenceforeground_productionper declared reference flow
structureFoundation, loadbearing structure and circulation coresrequiredInspect actual work-package completeness; each exchange is conditional on its real occurrenceforeground_productionper declared reference flow
enclosureRoof and envelope installationrequiredInspect actual work-package completeness; each exchange is conditional on its real occurrenceforeground_productionper declared reference flow
fitoutDwelling and community interior fit-outrequiredInspect actual work-package completeness; each exchange is conditional on its real occurrenceforeground_productionper declared reference flow
fixed_systemsFixed distribution systemsrequiredInspect actual work-package completeness; each exchange is conditional on its real occurrenceforeground_productionper declared reference flow
common_facilitiesCommon and community facilities installationconditionalWhen actual shared/community installations are in the delivery specificationforeground_productionper declared reference flow
site_utilitiesSite plant, water and direct releasesrequiredInspect actual work-package completeness; each exchange is conditional on its real occurrenceforeground_productionper declared reference flow
waste_transferWaste segregation and transferrequiredInspect actual work-package completeness; each exchange is conditional on its real occurrenceforeground_productionper declared reference flow
inbound_deliveryInbound delivery accountingrequiredInspect actual work-package completeness; each exchange is conditional on its real occurrenceforeground_productionper declared reference flow
handoverInspection, commissioning and handoverrequiredInspect actual work-package completeness; each exchange is conditional on its real occurrenceforeground_productionper declared reference flow

Process: Site preparation and groundworks (groundworks)

Reconcile this work package to drawings, issue/return records and subcontractor records; utilities shared across work packages are recorded once in site_utilities with attribution evidence. For absent activities record not-applicable evidence, not an invented quantity.

Inputs

Product flows
Crushed stone for foundation subbase (granular_fill)

Only where a crushed-stone subbase is installed; measure grading, compacted dimensions and delivered/returned mass. Do not substitute sand or excavated soil.

  • Selected flow: Crushed stone for foundation subbase
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Collect the actual exchange amount using cp_groundworks, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_groundworks
  • Sources: jrc-levels-boq-2021
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Non-contaminated excavated mineral soil for off-site disposal (soil_export)

Only when uncontaminated excavated mineral soil leaves as waste; survey bank and loose volumes, destination and contamination evidence. Reused on-site soil is an internal transfer.

  • Selected flow: Non-contaminated excavated mineral soil for off-site disposal
  • Flow property / unit: Volume 93a60a56-a3c8-22da-a746-0800200c9a66 / m3
  • Amount rule: Collect the actual exchange amount using cp_groundworks, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_groundworks
  • Sources: rics-wlca-2024
Elementary flows

Process: Foundation, loadbearing structure and circulation cores (structure)

Reconcile this work package to drawings, issue/return records and subcontractor records; utilities shared across work packages are recorded once in site_utilities with attribution evidence. For absent activities record not-applicable evidence, not an invented quantity.

Inputs

Product flows
Ready-mixed concrete delivered before placing (ready_mix)

For actually supplied fresh ready-mix only. Record strength/exposure designation, slump, batch, ticket volume, rejected returns, pumping, placing and curing. Site batching requires separate cement, aggregate, admixture and water rows with actual mix records.

  • Selected flow: Ready-mixed concrete delivered before placing
  • Flow property / unit: Volume 93a60a56-a3c8-22da-a746-0800200c9a66 / m3
  • Amount rule: Collect the actual exchange amount using cp_structure, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_structure
  • Sources: jrc-levels-boq-2021
steel rebar (reinforcement)

Only for actual non-alloy reinforcement supplied in irregularly wound coils, matching the public identity. Record grade, incoming coil form, diameter, actual straightening/bending/cutting, net delivered/returned mass and as-built private/common locations. Other alloy content, straight/cut-and-bent supply or prefabricated cages require separate verified identities; do not apply this coil identity to all reinforcement.

  • Selected flow: steel rebar 4f1a1837-7b3b-11dd-ad8b-0800200c9a66
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Collect the actual exchange amount using cp_structure, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_structure
  • Sources: jrc-levels-boq-2021
Kiln-dried sawn coniferous timber, at mill (timber_frame)

Only kiln-dried coniferous sawn members consistent with the at-mill supply identity. Record species, grade, moisture and treatment; engineered timber and treated members need separate rows. Include actual transport after the mill gate.

  • Selected flow: Kiln-dried sawn coniferous timber, at mill 50904047-e5b0-4110-990a-53751d250267
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Collect the actual exchange amount using cp_structure, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_structure
  • Sources: jrc-levels-boq-2021
Fabricated structural steel beam (steel_member)

Only fabricated structural steel beams actually installed; record steel grade, fabrication/coating state and member schedule; no replacement by reinforcing steel.

  • Selected flow: Fabricated structural steel beam
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Collect the actual exchange amount using cp_structure, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_structure
  • Sources: jrc-levels-boq-2021
Fired brick (fired_brick)

Only actual fired clay brick masonry; record void content, dimensions, mortar joints and installation location. This is not an adobe or concrete block identity.

  • Selected flow: Fired brick aedc2027-2154-4b0e-95fd-9baeb46d4153
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Collect the actual exchange amount using cp_structure, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_structure
  • Sources: jrc-levels-boq-2021
Cement-sand masonry mortar (masonry_mortar)

Only where cement-sand masonry mortar is consumed; retain actual wet/dry state, supplier or weighed batching recipe. A universal mortar recipe is forbidden.

  • Selected flow: Cement-sand masonry mortar
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Collect the actual exchange amount using cp_structure, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_structure
  • Sources: jrc-levels-boq-2021
Plywood formwork panel (plywood_formwork)

For plywood panels actually deployed for formwork, record grade, thickness, panel identifier and deployment area; do not charge each reuse as new manufacture. Apply allocation_reuse using the asset register.

  • Selected flow: Plywood formwork panel
  • Flow property / unit: Area 93a60a56-a3c8-19da-a746-0800200c9a66 / m2
  • Amount rule: Collect the actual exchange amount using cp_structure, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_structure
  • Sources: jrc-levels-boq-2021
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Elementary flows

Process: Roof and envelope installation (enclosure)

Reconcile this work package to drawings, issue/return records and subcontractor records; utilities shared across work packages are recorded once in site_utilities with attribution evidence. For absent activities record not-applicable evidence, not an invented quantity.

Inputs

Product flows
Hollow Glass (glazing)

Only matching installed double-glazing configuration; record pane thicknesses, cavity, coatings and opening area. The supplied insulating-glazing unit includes its internal spacer and seals; separately record the outer window frame and site-applied seals/fixings only where outside that unit gate. Do not double-count those inside the unit or treat glazing area as whole façade.

  • Selected flow: Hollow Glass 12053592-e6c4-4c56-ad15-a36a267c500a
  • Flow property / unit: Area 93a60a56-a3c8-19da-a746-0800200c9a66 / m2
  • Amount rule: Collect the actual exchange amount using cp_enclosure, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_enclosure
  • Sources: jrc-levels-boq-2021
Rock Wool (rock_wool)

Only the verified rock-wool product in actual envelope assemblies, not glass or slag wool; record density, thickness, facing and fire/thermal specification. Different insulation chemistry requires its own exchange.

  • Selected flow: Rock Wool 3a298360-f298-4a11-999e-11943f142cec
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Collect the actual exchange amount using cp_enclosure, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_enclosure
  • Sources: jrc-levels-boq-2021
Bituminous waterproofing membrane (waterproofing)

Only the matching bituminous membrane actually installed; record layers, thickness and overlaps. Adhesive or primer is a separate atomic input when used.

  • Selected flow: Bituminous waterproofing membrane 78f09f81-deb9-42dd-9418-7860faee0a2e
  • Flow property / unit: Area 93a60a56-a3c8-19da-a746-0800200c9a66 / m2
  • Amount rule: Collect the actual exchange amount using cp_enclosure, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_enclosure
  • Sources: jrc-levels-boq-2021
Finished aluminium window frame (window_frame)

Only finished aluminium window frames actually installed; retain finish, section, glazing separation and measured mass. Raw aluminium does not identify the finished frame.

  • Selected flow: Finished aluminium window frame
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Collect the actual exchange amount using cp_enclosure, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_enclosure
  • Sources: jrc-levels-boq-2021
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Elementary flows

Process: Dwelling and community interior fit-out (fitout)

Reconcile this work package to drawings, issue/return records and subcontractor records; utilities shared across work packages are recorded once in site_utilities with attribution evidence. For absent activities record not-applicable evidence, not an invented quantity.

Inputs

Product flows
Gypsum plasterboard (plasterboard)

Only the exact plasterboard identity installed in dwelling, dormitory or common partitions/ceilings; record thickness, facing and layout. Support studs and finishes are separate rows.

  • Selected flow: Gypsum plasterboard 3c6973a0-916b-4a04-923f-de0356448088
  • Flow property / unit: Area 93a60a56-a3c8-19da-a746-0800200c9a66 / m2
  • Amount rule: Collect the actual exchange amount using cp_fitout, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_fitout
  • Sources: jrc-levels-boq-2021
Ceramic Tile (ceramic_floor)

Only the verified single-fired polished ceramic floor tile installed indoors in actual private/common areas; collect dimensions, thickness, cut losses and installed area. Bedding mortar and grout are independent inputs.

  • Selected flow: Ceramic Tile 38191c2b-88f9-4b8d-9a1a-6b7b0b506169
  • Flow property / unit: Area 93a60a56-a3c8-19da-a746-0800200c9a66 / m2
  • Amount rule: Collect the actual exchange amount using cp_fitout, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_fitout
  • Sources: jrc-levels-boq-2021
Waterborne acrylic architectural paint (acrylic_paint)

Only actual waterborne acrylic architectural paint; record wet product mass and formulation/solids information. Solvent or pigment emissions require measured constituent-specific rows, never a generic VOC default.

  • Selected flow: Waterborne acrylic architectural paint
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Collect the actual exchange amount using cp_fitout, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_fitout
  • Sources: jrc-levels-boq-2021
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Elementary flows

Process: Fixed distribution systems (fixed_systems)

Reconcile this work package to drawings, issue/return records and subcontractor records; utilities shared across work packages are recorded once in site_utilities with attribution evidence. For absent activities record not-applicable evidence, not an invented quantity.

Inputs

Product flows
Insulated copper low-voltage building cable (copper_cable)

Only the identified insulated copper low-voltage cable actually installed; record insulation chemistry, conductor section, length and weighed or supplier-certified mass. Preserve a compatible public reference property if one is later verified.

  • Selected flow: Insulated copper low-voltage building cable
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Collect the actual exchange amount using cp_fixed_systems, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_fixed_systems
  • Sources: jrc-levels-boq-2021
UPVC tube (upvc_pipe)

Only the verified unplasticized PVC pipe product supplied under the actual CN construction-material gate; collect diameter, wall thickness, pressure/drainage class, joints, installed length and actual mass. Water and drainage networks are separate service/location registers.

  • Selected flow: UPVC tube a343bef6-8d18-4594-b1aa-99bc47172684
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Collect the actual exchange amount using cp_fixed_systems, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_fixed_systems
  • Sources: jrc-levels-boq-2021
Ceramic toilet bowl (ceramic_toilet)

Only when a ceramic toilet bowl is actually supplied in private/shared sanitary facilities. Record model, flushing interface, quantity and delivery completeness; cistern, seats and fittings outside its supply gate remain separate.

  • Selected flow: Ceramic toilet bowl
  • Flow property / unit: Number of items 01846770-4cfe-4a25-8ad9-919d8d378345 / item
  • Amount rule: Collect actual installed assembly count and complete configuration using cp_fixed_systems; do not substitute mass for item count.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_fixed_systems
  • Sources: jrc-levels-boq-2021
LED luminaire assembly (led_luminaire)

Only complete installed LED luminaires included in delivery; record driver, housing, lamp inclusion and controls. Commissioning electricity is site_utilities, not lifetime lighting energy.

  • Selected flow: LED luminaire assembly
  • Flow property / unit: Number of items 01846770-4cfe-4a25-8ad9-919d8d378345 / item
  • Amount rule: Collect actual installed assembly count and complete configuration using cp_fixed_systems; do not substitute mass for item count.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_fixed_systems
  • Sources: jrc-levels-boq-2021
Air-source heat-pump unit (heat_pump)

Only an actual installed air-source unit within the delivery contract; retain type, heat/cooling capacity, included components, refrigerant type/charge and commissioning. Refrigerant supplied separately or actually released requires its own substance-specific row; no default leakage or operational life.

  • Selected flow: Air-source heat-pump unit
  • Flow property / unit: Number of items 01846770-4cfe-4a25-8ad9-919d8d378345 / item
  • Amount rule: Collect actual installed assembly count and complete configuration using cp_fixed_systems; do not substitute mass for item count.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_fixed_systems
  • Sources: jrc-levels-boq-2021
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Elementary flows

Process: Common and community facilities installation (common_facilities)

Reconcile this work package to drawings, issue/return records and subcontractor records; utilities shared across work packages are recorded once in site_utilities with attribution evidence. For absent activities record not-applicable evidence, not an invented quantity.

Inputs

Product flows
Pump (water_booster)

Only an actual water-booster liquid pump compatible with this generic liquid-pump identity; record manufacturer, type, complete pump mass, motor inclusion, flow/head and served zones. Its manufacture is upstream; fitting and commissioning are foreground.

  • Selected flow: Pump bbd91be4-dc00-44c2-8bc1-f67ee79174a7
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Collect the actual exchange amount using cp_common_facilities, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_common_facilities
  • Sources: jrc-levels-boq-2021
Complete passenger lift assembly (passenger_lift)

Only if installed and within the handover specification; identify car, drive, controller, rails, doors, served storeys, rated capacity and commissioning. Do not infer a lift is mandatory in every multi-dwelling building.

  • Selected flow: Complete passenger lift assembly
  • Flow property / unit: Number of items 01846770-4cfe-4a25-8ad9-919d8d378345 / item
  • Amount rule: Collect the actual exchange amount using cp_common_facilities, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_common_facilities
  • Sources: jrc-levels-boq-2021
Mechanical ventilation fan assembly (ventilation_fan)

Only actually installed fans; retain capacity, controls, served rooms and complete assembly configuration. Ducts, dampers and filters are separate products, not silently included in a bare fan.

  • Selected flow: Mechanical ventilation fan assembly
  • Flow property / unit: Number of items 01846770-4cfe-4a25-8ad9-919d8d378345 / item
  • Amount rule: Collect the actual exchange amount using cp_common_facilities, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_common_facilities
  • Sources: jrc-levels-boq-2021
Fire-rated steel doorset (fire_door)

Only actual common-circulation/fire-compartment doorsets delivered; record frame, leaf, hardware, dimensions and specified fire performance with test/acceptance evidence. Do not invent a regulatory rating.

  • Selected flow: Fire-rated steel doorset
  • Flow property / unit: Number of items 01846770-4cfe-4a25-8ad9-919d8d378345 / item
  • Amount rule: Collect the actual exchange amount using cp_common_facilities, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_common_facilities
  • Sources: jrc-levels-boq-2021
Stainless-steel potable-water storage tank (water_tank)

Only where this specific tank is installed; record alloy, usable capacity, actual empty mass, insulation and served zones. Do not use water mass as tank manufacture mass.

  • Selected flow: Stainless-steel potable-water storage tank
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Collect the actual exchange amount using cp_common_facilities, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_common_facilities
  • Sources: jrc-levels-boq-2021
Galvanized steel ventilation duct (steel_duct)

Only installed galvanized ducts; retain sheet thickness, surface treatment, dimensions, joint schedule and actual mass. Cooking or clinical systems in community residences need their actual separate inventories.

  • Selected flow: Galvanized steel ventilation duct
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Collect the actual exchange amount using cp_common_facilities, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_common_facilities
  • Sources: jrc-levels-boq-2021
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Elementary flows

Process: Site plant, water and direct releases (site_utilities)

Reconcile this work package to drawings, issue/return records and subcontractor records; utilities shared across work packages are recorded once in site_utilities with attribution evidence. For absent activities record not-applicable evidence, not an invented quantity.

Inputs

Product flows
Alternating current (lv_electricity)

Only CN user-end electricity below 1 kV at the actual Chinese site and matched supply voltage. Meter lifting, pumping, curing, tools, temporary accommodation and commissioning; otherwise select the real regional/voltage identity.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ
  • Amount rule: Collect the actual exchange amount using cp_site_utilities, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_site_utilities
  • Sources: rics-wlca-2024
Alternating current (mv_electricity)

Only CN user-end electricity at 1–35 kV when the actual site meter is at that voltage; keep transformer losses explicit. Do not duplicate the same electricity at both voltage tiers.

  • Selected flow: Alternating current 3d76981f-964a-4865-b588-0e067a2a1163
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ
  • Amount rule: Collect the actual exchange amount using cp_site_utilities, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_site_utilities
  • Sources: rics-wlca-2024
Diesel (site_diesel)

Only matching actual diesel supplied for site engines/generators; retain batch fuel type, metered litres/mass, measured density if converting and actual net calorific value. Electricity generated internally is not a second purchased input.

  • Selected flow: Diesel fbd79004-188c-47a4-900b-96005d994690
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ
  • Amount rule: Collect the actual exchange amount using cp_site_utilities, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_site_utilities
  • Sources: rics-wlca-2024
Treated mains water supplied to site (supplied_water)

Only treated mains water crossing the technical system boundary; meter actual use for curing, cleaning, dust suppression and pressure tests. Recycled internal water is not a new input; do not replace this row with a natural resource flow.

  • Selected flow: Treated mains water supplied to site
  • Flow property / unit: Volume 93a60a56-a3c8-22da-a746-0800200c9a66 / m3
  • Amount rule: Collect the actual exchange amount using cp_site_utilities, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_site_utilities
  • Sources: rics-wlca-2024
Waste flows
Elementary flows
ground water (groundwater)

Only actual direct groundwater abstraction consumed as resource at the site, with aquifer/location evidence. Dewatering water transferred and returned is a separate routing account, not automatically consumed resource or wastewater.

  • Selected flow: ground water 4f462198-40cd-4184-8733-86648a20dc3f
  • Flow property / unit: Volume 93a60a56-a3c8-22da-a746-0800200c9a66 / m3
  • Amount rule: Collect the actual exchange amount using cp_site_utilities, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_site_utilities
  • Sources: rics-wlca-2024
river water (riverwater)

Only actual direct river-water resource intake, with source and abstraction measurements; not unspecified freshwater, lake water or wastewater. Record returns by actual receiving medium.

  • Selected flow: river water 805a7346-1664-4483-afe3-4b224be5e361
  • Flow property / unit: Volume 93a60a56-a3c8-22da-a746-0800200c9a66 / m3
  • Amount rule: Collect the actual exchange amount using cp_site_utilities, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_site_utilities
  • Sources: rics-wlca-2024

Outputs

Product flows
Waste flows
Elementary flows
carbon dioxide (fossil) (diesel_co2)

Conditional immediate fossil CO2 release to unspecified air from actual site diesel combustion. Collect actual fuel carbon and oxidation evidence or applicable measured exhaust data. Separate fossil/bio fractions and avoid overlap with combustion-inclusive background datasets.

  • Selected flow: carbon dioxide (fossil) 08a91e70-3ddc-11dd-923d-0050c2490048
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Collect the actual exchange amount using cp_site_utilities, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_site_utilities
  • Sources: rics-wlca-2024
nitrogen monoxide (diesel_no)

Only supported speciated NO mass to immediate unspecified air for the actual engine, load and exhaust control. NOx reported as NO2-equivalent cannot be treated as NO mass.

  • Selected flow: nitrogen monoxide 08a91e70-3ddc-11dd-96ee-0050c2490048
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Collect the actual exchange amount using cp_site_utilities, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_site_utilities
  • Sources: rics-wlca-2024
nitrogen dioxide (diesel_no2)

Only separately supported NO2 mass to immediate unspecified air. Distinguish NO, nitrogen, N2O and NOx expressed as NO2-equivalent; no automatic default emission factor.

  • Selected flow: nitrogen dioxide 08a91e70-3ddc-11dd-96e5-0050c2490048
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Collect the actual exchange amount using cp_site_utilities, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_site_utilities
  • Sources: rics-wlca-2024
particles (PM10) (construction_pm10)

Only supported actual PM10 release to immediate unspecified air from site earthworks/handling/traffic or engines, with source-specific evidence and weather/control conditions. Avoid overlapping PM fractions; historical AP-42 supports qualitative occurrence, not a current universal factor.

  • Selected flow: particles (PM10) 08a91e70-3ddc-11dd-91be-0050c2490048
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Collect the actual exchange amount using cp_site_utilities, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_site_utilities
  • Sources: epa-construction-dust-2010

Process: Waste segregation and transfer (waste_transfer)

Reconcile this work package to drawings, issue/return records and subcontractor records; utilities shared across work packages are recorded once in site_utilities with attribution evidence. For absent activities record not-applicable evidence, not an invented quantity.

Inputs

Product flows
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Hardened concrete construction offcut (concrete_waste)

Only hardened concrete offcuts removed for treatment; distinguish wet concrete returns and washout liquid.

  • Selected flow: Hardened concrete construction offcut
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Collect the actual exchange amount using cp_waste_transfer, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_waste_transfer
  • Sources: rics-wlca-2024
Untreated sawn timber offcut (timber_waste)

Only untreated sawn-wood offcuts; distinguish coated, glued or preservative-treated waste with separate rows.

  • Selected flow: Untreated sawn timber offcut
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Collect the actual exchange amount using cp_waste_transfer, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_waste_transfer
  • Sources: rics-wlca-2024
Gypsum plasterboard offcut (gypsum_waste)

Only segregated plasterboard offcuts; retain facing, contamination and destination.

  • Selected flow: Gypsum plasterboard offcut
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Collect the actual exchange amount using cp_waste_transfer, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_waste_transfer
  • Sources: rics-wlca-2024
Corrugated cardboard packaging waste (carton_waste)

Only discarded corrugated cardboard; reconcile supply packaging and actual transfer weights.

  • Selected flow: Corrugated cardboard packaging waste
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Collect the actual exchange amount using cp_waste_transfer, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_waste_transfer
  • Sources: rics-wlca-2024
Polyethylene packaging film waste (film_waste)

Only identified polyethylene packaging film; other polymers require separate atomic rows.

  • Selected flow: Polyethylene packaging film waste
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Collect the actual exchange amount using cp_waste_transfer, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_waste_transfer
  • Sources: rics-wlca-2024
Contained concrete-chute washwater for off-site treatment (concrete_washwater)

Only collected chute/pump washwater exported for treatment. Record pH, suspended solids, volume and receiver. Offsite truck-drum washing belongs to its actual offsite process; actual discharges need separate measured constituents and receiving media.

  • Selected flow: Contained concrete-chute washwater for off-site treatment
  • Flow property / unit: Volume 93a60a56-a3c8-22da-a746-0800200c9a66 / m3
  • Amount rule: Collect the actual exchange amount using cp_waste_transfer, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_waste_transfer
  • Sources: epa-concrete-washout-2012
Elementary flows

Process: Inbound delivery accounting (inbound_delivery)

Reconcile this work package to drawings, issue/return records and subcontractor records; utilities shared across work packages are recorded once in site_utilities with attribution evidence. For absent activities record not-applicable evidence, not an invented quantity.

Inputs

Product flows
Freight Truck (road_freight)

Only actual inbound road freight compatible with the verified truck identity and not included in the supplier gate. Record vehicle/load class, each consignment and actual route; waste hauling is separate.

  • Selected flow: Freight Truck d55f1329-cd61-44c0-8000-9367d38d5634
  • Flow property / unit: Goods transport (massdistance) 838aaa20-0117-11db-92e3-0800200c9a66 / tkm
  • Amount rule: Collect the actual exchange amount using cp_inbound_delivery, retaining the row unit, physical state and this building attribution.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_inbound_delivery
  • Sources: rics-wlca-2024
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Elementary flows

Process: Inspection, commissioning and handover (handover)

Reconcile this work package to drawings, issue/return records and subcontractor records; utilities shared across work packages are recorded once in site_utilities with attribution evidence. For absent activities record not-applicable evidence, not an invented quantity.

Inputs

Product flows
Waste flows
Elementary flows

Outputs

Product flows
Completed multi-dwelling or community residential building (reference_building)

One whole building at the surveyed site and signed declared delivery configuration, including its attributed common structure/facilities. Rooms, dwellings and shared cores are not extra building outputs.

  • Selected flow: Completed multi-dwelling or community residential building
  • Flow property / unit: Number of items 01846770-4cfe-4a25-8ad9-919d8d378345 / item
  • Amount rule: 1 item
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per declared reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_handover
  • Sources: un-cpc-3-53112
Waste flows
Elementary flows

7. Allocation and Co-product Handling

rule_idapplies_torulesource_ids
allocation_wholedatasetThe reference is one building. Private apartments/rooms, cores and common facilities are components, not co-products automatically requiring division by dwelling count. Keep the whole-building inventory. Supplementary dwelling/room reports must preserve the building total and identify common-space assignment.rics-wlca-2024
allocation_sharedall inventory rowsFirst subdivide meters, deliveries and work packages to avoid allocation. Where shared basements, utilities or central facilities serve multiple buildings/uses, record their complete common ledger once, then justify shares by actual physical service, measured GIA, occupancy/capacity or other evidenced use relationships. No universal equal-per-dwelling or area ratio is prescribed. Declare numerator/denominator and unmatched uses; all assigned and unassigned shares reconcile to one, with sensitivity if the relation is uncertain.rics-wlca-2024; ghg-allocation-2011
allocation_reuseplywood_formwork; site_utilitiesKeep asset identifiers for reused formwork, scaffolding and equipment. Manufacturing burdens use evidenced total lifetime activity/reuses and actual project deployment; transport, repairs, losses and end-of-life remain explicit. Cumulative manufacturing shares across projects, periods and reuse shall not exceed one; an observation period may allocate only its attributable manufacturing share. Unknown lifetime/total activity is a review gap, never a reset to full manufacture per project.rics-wlca-2024; ghg-allocation-2011
allocation_wastewaste_transferRecord actual waste transfer, treatment coverage and recovered-product destination separately; do not treat construction scrap as an automatic avoided-production credit. Declare recycling allocation and supplier gate overlap consistently.ghg-allocation-2011

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_groundworksgroundworksactual row exchangeforeground_recordsInitial site, excavation bank/loose geometry, fill grade/weights, contamination, destinationsSurvey and weighbridge records before/after work; retain ground investigations and disposal ticketsrow-specific kg, m3, m2, MJ, item, t*kmEach delivery/event and meter interval; each acceptanceComplete actual construction period through signed handover; disclose gapsDeclared whole building and attributable subcontracted/shared workper declared reference flowcalibration, signed tickets, surveys, original tests, reconciliation and uncertainty
cp_structurestructureactual row exchangeforeground_recordsAs-built member schedules, material states/grades, concrete tickets, reinforcement cutting, formwork asset deployments, curing/pumping/liftingReconcile as-built drawings, delivery/return tickets, measured quantities and temporary-work logsrow-specific kg, m3, m2, MJ, item, t*kmEach delivery/event and meter interval; each acceptanceComplete actual construction period through signed handover; disclose gapsDeclared whole building and attributable subcontracted/shared workper declared reference flowcalibration, signed tickets, surveys, original tests, reconciliation and uncertainty
cp_enclosureenclosureactual row exchangeforeground_recordsRoof/façade layers, opening/assembly areas, thicknesses, grades, installed and discarded quantitiesSurvey actual assemblies and reconcile supplier specification and issue/return recordsrow-specific kg, m3, m2, MJ, item, t*kmEach delivery/event and meter interval; each acceptanceComplete actual construction period through signed handover; disclose gapsDeclared whole building and attributable subcontracted/shared workper declared reference flowcalibration, signed tickets, surveys, original tests, reconciliation and uncertainty
cp_fitoutfitoutactual row exchangeforeground_recordsPrivate/common room register, installed partition/floor/finish state, quantities and completenessReconcile room-by-room fit-out schedule and delivery/measurement records, with actual withheld workrow-specific kg, m3, m2, MJ, item, t*kmEach delivery/event and meter interval; each acceptanceComplete actual construction period through signed handover; disclose gapsDeclared whole building and attributable subcontracted/shared workper declared reference flowcalibration, signed tickets, surveys, original tests, reconciliation and uncertainty
cp_fixed_systemsfixed_systemsactual row exchangeforeground_recordsCircuit/pipe schedule, lengths, sections, material identity, equipment interfaces, installed assembly counts/configuration, refrigerant charge/actual losses and test recordsMeasure installed networks; reconcile supplier mass/length and pressure/electrical test reportsrow-specific kg, m3, m2, MJ, item, t*kmEach delivery/event and meter interval; each acceptanceComplete actual construction period through signed handover; disclose gapsDeclared whole building and attributable subcontracted/shared workper declared reference flowcalibration, signed tickets, surveys, original tests, reconciliation and uncertainty
cp_common_facilitiescommon_facilitiesactual row exchangeforeground_recordsAsset/model, complete assembly mass/count, capacity, served zones, shared/private attribution, commissioning utilitiesRead manufacturer/as-built schedules and signed commissioning records; weigh or use traceable product mass where kg is usedrow-specific kg, m3, m2, MJ, item, t*kmEach delivery/event and meter interval; each acceptanceComplete actual construction period through signed handover; disclose gapsDeclared whole building and attributable subcontracted/shared workper declared reference flowcalibration, signed tickets, surveys, original tests, reconciliation and uncertainty
cp_site_utilitiessite_utilitiesactual row exchangeforeground_recordsMeters, voltage/site, fuel batch/density/net calorific value/carbon, engine hours/duty, water source/returns, exhaust species and dust/control/weatherRead calibrated meters and fuel issue/return logs; use measured site-specific exhaust/resource data and documented applicable models where direct measurement is unavailablerow-specific kg, m3, m2, MJ, item, t*kmEach delivery/event and meter interval; each acceptanceComplete actual construction period through signed handover; disclose gapsDeclared whole building and attributable subcontracted/shared workper declared reference flowcalibration, signed tickets, surveys, original tests, reconciliation and uncertainty
cp_waste_transferwaste_transferactual row exchangeforeground_recordsAtomic waste identity, state, quantity, contamination, carrier and receiver/treatment; washwater pH and solidsUse segregated weighbridge/volume tickets and receiver receipts; track on-site reuse and offsite processing distinctlyrow-specific kg, m3, m2, MJ, item, t*kmEach delivery/event and meter interval; each acceptanceComplete actual construction period through signed handover; disclose gapsDeclared whole building and attributable subcontracted/shared workper declared reference flowcalibration, signed tickets, surveys, original tests, reconciliation and uncertainty
cp_inbound_deliveryinbound_deliveryactual row exchangeforeground_recordsConsignment mass, vehicle, actual route length, load, empty return and supplier included gatesRead actual transport logs and supplier boundary declarations; calculate each evidenced leg, no assumed distancerow-specific kg, m3, m2, MJ, item, t*kmEach delivery/event and meter interval; each acceptanceComplete actual construction period through signed handover; disclose gapsDeclared whole building and attributable subcontracted/shared workper declared reference flowcalibration, signed tickets, surveys, original tests, reconciliation and uncertainty
cp_handoverhandoveractual row exchangeforeground_recordsBuilding/site identifier, residential/community use, dwelling/room count, capacity, delivered private/common configuration, acceptance and construction datesReconcile signed handover, as-built drawings, room/asset register and inspection records; do not infer occupancy approvalitemEach delivery/event and meter interval; each acceptanceComplete actual construction period through signed handover; disclose gapsDeclared whole building and attributable subcontracted/shared workper declared reference flowcalibration, signed tickets, surveys, original tests, reconciliation and uncertainty
cp_geometryhandoverBuilding geometry and common-space identityforeground_recordsfloor plates; dwelling/room areas; corridors/stairs/plant/amenities; footprint; storeys; actual resident capacity; measurement conventionSurvey as-built plans/site and reconcile mutually exclusive area categories to the declared gross internal area. Document walls/voids/parking conventions and excluded spaces.m2At as-built verification and handoverActual delivered building stateAll included storeys and shared areas attributed to this buildingper declared reference flowsurvey method, drawings, area schedule and signed acceptance

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
project_ledgerall inventory rowsReconcile actual deliveries, returns, work-package issues, waste transfers and meter records; attribute the documented quantity to this single reference building without dividing by a default dwelling count or area. Preserve internal transfers without double counting.cp_groundworks; cp_structure; cp_enclosure; cp_fitout; cp_fixed_systems; cp_common_facilities; cp_site_utilities; cp_waste_transfer; cp_inbound_delivery; cp_handoverrow amount per declared reference flowrics-wlca-2024
electricity_conversionlv_electricity; mv_electricityMultiply actual metered kWh by 3.6 to report MJ; retain the same delivered electricity and voltage gate; separately evidence any transformer losses.cp_site_utilitiesMJ per declared reference flow
fuel_conversionsite_dieselUse measured fuel mass and batch net calorific value for MJ; litres require batch/site density at recorded conditions. Actual carbon/oxidation evidence determines the fossil CO2 component independently.cp_site_utilitiesfuel MJ per declared reference flow
freight_legsroad_freightFor each actual leg multiply documented payload tonnes by travelled km and sum attributable legs. Report allocation/empty returns and exclude legs already in supplier data.cp_inbound_deliveryt*km per declared reference flowrics-wlca-2024

Data Quality Requirements

requirement_idApplies toRequirementEvidence
quality_completenessdatasetReconcile shell/core/external and every private/common work package to delivered scope. Add all actual materials/equipment, route-specific waste and releases absent from these rows. Absence needs documented not-applicable justification; uncollected required quantities are gaps, not zero.jrc-levels-boq-2021; cp_handover
quality_sharedcommon_facilitiesRetain whole-building and parent shared-facility ledgers, capacity/service evidence and area definitions. Do not equate dwelling count, beds, rooms and residents or silently exclude common areas.rics-wlca-2024; cp_geometry; cp_common_facilities
quality_representativenessall inventory rowsReport construction dates, site, supplier technology/region, measured vs modelled amounts, calibration, unmetered periods, uncertainty and upstream compatibility. Distinguish missing measurements/UUIDs from demonstrated absence.cp_site_utilities; cp_handover
quality_environmentsite_utilities; waste_transferDirect pollutant estimates require actual source chemistry, medium/submedium, immediate/long-term state and supported engine/soil/weather/treatment conditions. Report noise and water-routing data/characterization gaps; never treat an emission name as proof of occurrence.epa-construction-dust-2010; epa-concrete-washout-2012

9. Validation Rules

rule_idapplies_torulesource_ids
validate_identityreference_buildingVerify the residential/community category and one real whole-building output, signed delivery state, actual count/capacity and all qualifiers. A room or construction service cannot use this reference identity.un-cpc-3-53112
validate_geometry_shareddatasetCheck measured private/common/service area categories and conventions against as-built plans; reconcile all assigned shared facility/basement burdens and total project quantities. Any supplementary occupant/dwelling attribution must preserve whole-building totals and disclose its actual basis.rics-wlca-2024
validate_atomic_unitsall inventory rowsCheck each single physical/chemical exchange, exact public reference property/unit group, conditional applicability, collection protocol and common denominator in both languages. Blank UUID identities remain registered gaps; a near label never authorizes substitution.
validate_stagesdatasetVerify manufacture linkage, transport and construction coverage separately; no full cradle-to-gate/full-life claim when stages or required quantities are missing. Acceptance evidence does not establish PCR scientific approval or local occupancy permission.rics-wlca-2024
validate_releasessite_utilities; waste_transferCheck fossil/bio origin, NO vs NO2/N2O, nonoverlapping particulate fractions, natural intake vs technical water/wastewater and actual receiving medium. Prevent background combustion/treatment duplication and preserve unresolved required environmental data as incomplete coverage.epa-concrete-washout-2012; epa-construction-dust-2010
validate_asset_sharesplywood_formwork; site_utilitiesVerify reused-asset identity, lifetime-activity evidence and cumulative manufacturing shares across projects/periods not exceeding one. Missing denominators require review rather than resetting asset manufacture.rics-wlca-2024; ghg-allocation-2011

10. Published Dataset Profile

FieldValue
dataset_roleforeground_dataset
downstream_usesecondary_dataset; background_dataset
allowed_useDeclared whole residential/community building construction delivery, with explicit upstream linking and stage coverage; comparisons only with equivalent delivery scope, housing function, geometry and shared facility treatment
excluded_useFull lifetime/service-year claim; universal kg/building or material recipe; legal approval; construction service; private-apartment-only footprint presented as whole building
required_metadataAll reference qualifiers; private/common and parent assessment registers; actual structure/route; acceptance scope; stage and upstream gates; actual data/calibration/allocation sources
required_quality_disclosureMeasured/modelled scope, missing upstream and quantities, unresolved identities, environmental/characterization gaps, representativeness, shared/reused asset allocation uncertainty and excluded later stages
update_triggerChanges to use/capacity/dwelling configuration, site/geometry, common installations, delivery state, structural route, suppliers, measured records or evidence status

11. Data Sources

source_idtypereferencePCR use and limitations
un-cpc-3-53112official_guidanceUN Statistics Division, CPC Version 3.0 subclass 53112 explanatory note. https://unstats.un.org/unsd/classifications/Econ/Structure/Detail/EN/2100/53112Category boundary: three or more dwellings and community residences. Classification establishes neither construction recipe nor legal permission.
jrc-levels-boq-2021official_guidanceEuropean Commission JRC, Level(s) indicator 2.1 Bill of Quantities, publication v1.1 January 2021, PDF/printed pp.23–24, Table 2. https://susproc.jrc.ec.europa.eu/product-bureau/sites/default/files/2021-01/UM3_Indicator_2.1_v1.1_34pp.pdfElement/installed-system coverage prompts only; no example quantities, default material intensity or lifespans adopted. Actual project records determine every quantity.
rics-wlca-2024standardRICS Whole life carbon assessment for the built environment, second edition, version 3 August 2024; section 3.5–3.6 printed p.36/PDF p.44; section 5.1.4 printed pp.80–82/PDF pp.88–90. https://www.rics.org/content/dam/ricsglobal/documents/standards/Whole_life_carbon_assessment_PS_Sept23.pdf.Shared/community facilities, linked-building assessment, site activities and reusable temporary works; no default emission rates, service lives or blanket RICS whole-life compliance claim.
ghg-allocation-2011official_guidanceWRI/WBCSD Product Life Cycle Accounting and Reporting Standard, 2011, chapter 9, Tables 9.1–9.2 printed p.63/PDF p.65. https://ghgprotocol.org/sites/default/files/standards/Product-Life-Cycle-Accounting-Reporting-Standard_041613.pdfHistorical method hierarchy for subdivision and evidenced allocation; no default shares or new regulatory claim.
epa-construction-dust-2010official_guidanceUS EPA AP-42 13.2.3 Heavy Construction Operations, January 1995 corrected February 2010, printed p.13.2.3-1/PDF p.1. https://www.epa.gov/sites/default/files/2020-10/documents/13.2.3_heavy_construction_operations.pdfHistorical qualitative dust/activity/weather relationship only; no universal current factor or automatic emission.
epa-concrete-washout-2012official_guidanceUS EPA Concrete Washout, EPA-833-F-11-006 February 2012, PDF pp.1–2. https://www.epa.gov/sites/default/files/2015-11/documents/concretewashout_0.pdfHistorical washout state and routing distinctions; actual measured composition, destinations and local permits must be collected independently.

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 4
Rule IDApplies toRuleSource IDs
boundary_deliveryall inventory rowsAccount for the delivered whole entity and every actually occurring exchange in shell, core, private and communal works. These conditional rows are minimum inspection prompts, not a closed universal bill of materials. Add separate atomic rows for actual roof coverings, fittings, stairs, external works, heat/cooling plant, community kitchens, security/fire systems and their specific materials when present. No alternative is silently substituted or omitted.jrc-levels-boq-2021, rics-wlca-2024
boundary_stagesdatasetManufacture of installed equipment/materials is upstream; fitting, lifting, site conditioning, pressure tests and commissioning are foreground. Operation, real future maintenance/renewal and final dismantling are separately scoped later stages. Initial site demolition and clearance are construction-enabling activities when actually undertaken, not future demolition. Disclose missing A1–A3/A4/A5 coverage.rics-wlca-2024
boundary_commoncommon_facilitiesInclude actual shared stairs, cores, plant rooms and residential-community facilities in the whole-building ledger, even if separately contracted. Identify central systems and served zones. For linked buildings with shared basements, establish a combined assessment ledger before attributing building shares; disclose the parent assessment and conservation. Do not hide all shared works outside private apartment area.rics-wlca-2024
boundary_releasessite_utilitiesRecord technical supplied water separately from natural resource intake; track dewatering returns by destination and chemistry. Washout liquid/solids are not freshwater. Inventory actual direct exhaust/dust/discharges only with release evidence; assess construction noise using actual equipment/receptor/time evidence and disclose characterization gaps without inventing a mass flow.epa-concrete-washout-2012, epa-construction-dust-2010
Allocation rules · 4
Rule IDApplies toRuleSource IDs
allocation_wholedatasetThe reference is one building. Private apartments/rooms, cores and common facilities are components, not co-products automatically requiring division by dwelling count. Keep the whole-building inventory. Supplementary dwelling/room reports must preserve the building total and identify common-space assignment.rics-wlca-2024
allocation_sharedall inventory rowsFirst subdivide meters, deliveries and work packages to avoid allocation. Where shared basements, utilities or central facilities serve multiple buildings/uses, record their complete common ledger once, then justify shares by actual physical service, measured GIA, occupancy/capacity or other evidenced use relationships. No universal equal-per-dwelling or area ratio is prescribed. Declare numerator/denominator and unmatched uses; all assigned and unassigned shares reconcile to one, with sensitivity if the relation is uncertain.rics-wlca-2024, ghg-allocation-2011
allocation_reuseplywood_formwork; site_utilitiesKeep asset identifiers for reused formwork, scaffolding and equipment. Manufacturing burdens use evidenced total lifetime activity/reuses and actual project deployment; transport, repairs, losses and end-of-life remain explicit. Cumulative manufacturing shares across projects, periods and reuse shall not exceed one; an observation period may allocate only its attributable manufacturing share. Unknown lifetime/total activity is a review gap, never a reset to full manufacture per project.rics-wlca-2024, ghg-allocation-2011
allocation_wastewaste_transferRecord actual waste transfer, treatment coverage and recovered-product destination separately; do not treat construction scrap as an automatic avoided-production credit. Declare recycling allocation and supplier gate overlap consistently.ghg-allocation-2011
Validation rules · 6
Rule IDApplies toRuleSource IDs
validate_identityreference_buildingVerify the residential/community category and one real whole-building output, signed delivery state, actual count/capacity and all qualifiers. A room or construction service cannot use this reference identity.un-cpc-3-53112
validate_geometry_shareddatasetCheck measured private/common/service area categories and conventions against as-built plans; reconcile all assigned shared facility/basement burdens and total project quantities. Any supplementary occupant/dwelling attribution must preserve whole-building totals and disclose its actual basis.rics-wlca-2024
validate_atomic_unitsall inventory rowsCheck each single physical/chemical exchange, exact public reference property/unit group, conditional applicability, collection protocol and common denominator in both languages. Blank UUID identities remain registered gaps; a near label never authorizes substitution.
validate_stagesdatasetVerify manufacture linkage, transport and construction coverage separately; no full cradle-to-gate/full-life claim when stages or required quantities are missing. Acceptance evidence does not establish PCR scientific approval or local occupancy permission.rics-wlca-2024
validate_releasessite_utilities; waste_transferCheck fossil/bio origin, NO vs NO2/N2O, nonoverlapping particulate fractions, natural intake vs technical water/wastewater and actual receiving medium. Prevent background combustion/treatment duplication and preserve unresolved required environmental data as incomplete coverage.epa-concrete-washout-2012, epa-construction-dust-2010
validate_asset_sharesplywood_formwork; site_utilitiesVerify reused-asset identity, lifetime-activity evidence and cumulative manufacturing shares across projects/periods not exceeding one. Missing denominators require review rather than resetting asset manufacture.rics-wlca-2024, ghg-allocation-2011
Processes and inputs/outputs · 10
Process IDProcess nameInput flowsOutput flows
groundworksSite preparation and groundworks11
structureFoundation, loadbearing structure and circulation cores70
enclosureRoof and envelope installation40
fitoutDwelling and community interior fit-out30
fixed_systemsFixed distribution systems50
common_facilitiesCommon and community facilities installation60
site_utilitiesSite plant, water and direct releases64
waste_transferWaste segregation and transfer06
inbound_deliveryInbound delivery accounting10
handoverInspection, commissioning and handover01

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page