TianGong PCR

New oak wine barrel production

Lifecycle status
Candidate
Content maturity
Authored methodology
Current version
0.1.0Last updated
Readiness
Review required

Methodology and translation states come from the source record; publishing this website does not change their review status.

Content languages

zh-CN · Aligned
Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:31703 · narrower

Source

1. Scope and Applicability

This methodology covers production of new, unused wine barrels with solid oak staves and oak heads retained by permanent steel hoops, accepted at the cooperage gate. It distinguishes rough staves, seasoned blanks, formed shells and leak-tested complete barrels. Toast level is a declared product configuration, not a universal temperature or emission factor. Natural seasoning, mechanical operations, steam/fire bending, sensory toasting, hoop fitting and leak tests retain separate activity records. The factory examples establish feasible routes rather than an industry-average bill of materials. [seguin-process; seguin-toasts; taransaud-quality]

Excluded products are saleable stave/head semifinished products as reference outputs, other-wood or composite barrels, vats/tubs, charred spirits casks, barrels after wine use and reconditioned barrels. Refurbishment requires prior-use history, cleaning, removed contaminated wood, repair and service-capacity evidence; it cannot inherit this new-manufacture reference. Supplier forest origin, oak species, capacity, seasoning time, toast intensity and useful life have no default values. Optional actual consumables, treatments, emissions and packaging must be added as one atomic exchange each before a dataset claims completeness. [usda-wood-2021; thermal-wood-2005]

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.other-transportable-goods-except-metal-products-machinery-and-equipment.products-of-wood-cork-straw-and-plaiting-materials.casks-barrels-vats-tubs-and-other-coopers-products-and-parts-thereof-of-wood-including-staves
classification_refsCPC 3.0 31703; narrower; scope and accepted decisions: classifications/mappings/cpc-3.0-to-pcr.yaml and its referenced ADRs
covered_productsNew all-oak wine barrels, bare black or galvanized steel hoops, declared bending and toast configuration
excluded_productsStaves/heads sold alone; used/refurbished barrels; non-oak or composite barrels; vats/tubs; charred spirits casks
representative_productOne specified new oak wine barrel model; no fixed oak origin, capacity or service life
production_routeDeclared split/sawn oak receipt or verified seasoned blank; natural seasoning; machining; rosing; steam/fire bending; toast; head/hoop assembly; leak test; net-mass acceptance and packing
market_stateNew, unused, empty, accepted complete barrel at factory gate

3. Reference Flow

FieldValue
WhatProvide a complete new oak container for the declared wine maturation or fermentation application
How much1 kg accepted net new oak wine barrel; also report accepted barrel count and each model capacity, without converting capacity to product mass
How wellMeet the declared model, stave/head construction, hoop specification, toast profile and documented leak-test criterion; compare only equivalent configurations
How long or cycleOne manufacture and factory acceptance cycle. Wine use cycles and useful life require independent user evidence; no default years or fills
reference_flow_linkaccepted_new_oak_barrel
FieldValue
Reference amount1
Reference product flowCasks, barrels, vats, tubs and other coopers' products and parts thereof, of wood, including staves 8b100f0f-21c2-4373-b469-a67b4f87973e
Reference flow propertyMass 93a60a56-a3c8-11da-a746-0800200b9a66
Reference unit groupUnits of mass 93a60a57-a4c8-11da-a746-0800200c9a66
Reference unitkg
Required qualifiersnew/unused state; wine function; oak species and verified origin or explicitly unknown origin; split/sawn route and receipt moisture; seasoning start/end and supplier boundary; measured barrel net mass and moisture; accepted count; nominal/verified capacity; stave/head dimensions; permanent hoop material/coating/mass; supplied closure; bending method; toast label and actual temperature/time program, fuel and oxygen conditions; leak-test method/criterion/result; factory/year; delivery boundary; packaging separately; biogenic carbon basis; dataset allocation and missing evidence

The broad product UUID includes the physically specified finished barrel; it does not establish an oak-specific background dataset. Declare all qualifiers in dataset metadata or equivalent evidence; missing identity or acceptance qualifiers make the data package incomplete. A capacity-normalized wine-service comparison requires demonstrated capacity, service cycles and equivalent wine-quality function; 1 kg is an inventory normalization, not proof of equal wine service.

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
reference_massaccepted_new_oak_barrelMasskgQ is measured accepted net mass of a compatible batch of complete barrels after test drainage, including installed hoops and supplied closure but excluding test water and dispatch packaging. Use cp_acceptance. All inventory rows use per 1 kg reference flow; keep raw batch totals.
wood_water_basisseparately measured wood components with state-validated methodsMasskgRecord actual wood-component wet mass and dry-basis moisture u for each stage, using a method independently validated for the actual species and physical/thermal/chemical state. m_wood_dry = m_wood_wet/(1+u), where u is kg water/kg oven-dry wood measured on that same component; retain non-wood constituents separately. Use oak-appropriate sampling and report extractive/volatile-loss uncertainty; no generic density or softwood MC. This component rule never replaces whole accepted barrel Q including installed hoops/closure, whole rejected-barrel mass or native whole residue exchange mass. Inorganic ash, carbonized/chemically transformed char, metal, plastic and liquid residues require their own compatible solids/water/composition measurements; do not automatically apply ordinary wood MC or wood-carbon fractions to transformed material. Valid unchanged wood components after thermal processing remain included only with actual-state validation. Moisture loss is not automatically wood yield loss. [usda-wood-2021]
power_basisall electricity rowsNet calorific valueMJFor verified <1 kV alternating current, measured kWh × 3.6 = MJ electrical energy. Match supplier voltage and delivered boundary; no fuel calorific or generation-efficiency conversion is inferred from the database property label.
gas_volume_basisall natural gas rowsVolumem3Use cp_heat for measured volume at stated T/P, composition, wet/dry state and compressibility; match the background reference-volume convention. Unknown compatibility remains pending; no assumed density from secondary flow coefficients.
steam_basisbending_purchased_steamMasskgCollect delivered steam mass, pressure, temperature, dryness and return conditions. A net delivered heat calculation needs supplier enthalpy definition and a site steam/condensate/blowdown balance; a MJ property alone is insufficient. Do not select high-pressure or source-specific paper/chemical steam for unspecified cooperage supply.
elementary_basisall elementary output rowsMasskgKeep chemical/CAS identity, carbon origin, source stage and receiving air subclass. NOx mass versus NO2-equivalent requires explicit compatible definitions; exclude N2O and avoid double-counting NO/NO2. PM2.5, PM2.5-PM10 and >PM10 are disjoint emitted fractions, not three cumulative PM totals. [epa-wood-boilers; epa-sawmill-pte-scope]

5. System Boundary

Boundary Abstraction

FieldValue
declared_starting_conditionUntreated green split/sawn oak blanks delivered to seasoning/cooperage, or separately identified purchased air-seasoned oak blanks with verified upstream seasoning coverage
starting_condition_roleForeground cut-in with upstream cradle burdens explicitly linked; not a burden-free raw material or universal industry start
product_classification_scopeNew oak wine barrel subset of CPC3.0 31703; covers no stave-only/reference vat or refurbishment datasets
recursive_input_ruleA purchased prepared blank or part requires an upstream provider for its actual prior manufacturing/seasoning. Internal retained wood and recirculated water are physical stage records, not new purchases or duplicate cradle burdens
upstream_dataset_requirementSpecies/route/state-compatible forestry and blank preparation, delivery transport, steel hoop fabrication/coating, delivered utilities, packaging and waste treatment; unresolved providers disclosed and completed before cradle-to-gate claims
disclosureReceipt state, upstream coverage, measured stage map, utilities/purchased versus internal heat, waste destination, test acceptance, allocation, exclusions and omitted evidence. Finished barrel ready for dispatch at factory gate; wine use and end-of-life outside this production dataset
rule_idapplies_torulesource_ids
boundary_statesnew_barrel_productionRetain separate rough/seasoned/stave-shell/complete-barrel states and all actually executed stages. Model the integrated cooperage unit from receipt through accepted dispatch once; stage transfers are metered internal ledgers, not extra reference outputs.seguin-process, taransaud-quality
boundary_thermalthermal and boiler stagesDistinguish bending heat from sensory toast, direct fuel burning from degradation of retained oak, and separate boiler outlets. Use EPA boiler evidence only for a matching actual boiler; open fires require their own site emission evidence.seguin-toasts, thermal-wood-2005, epa-wood-boilers
boundary_materialall inventory rowsInclude actual raw materials, utility use, rejects, wastewater, wastes and emissions. A UUID gap does not authorize omitting a physically present flow; preserve a concrete atomic exchange and provider/identity gap. Document any actual treatment additive, adhesive, oil, packaging component or direct natural-water release with its own row before completeness.usda-wood-2021, taransaud-quality
boundary_carbonwood and air outputsKeep dry wood, retained toasted-layer carbon, exported residues, collected char/ash carbon and emitted chemical carbon as a reconciled physical account; retain biogenic CO2 in LCI. Upstream forest uptake is counted once in the linked boundary and not inferred as a negative cooperage emission.usda-wood-2021, thermal-wood-2005, epa-wood-boilers

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
new_barrel_productionNew oak wine barrel productionrequiredAll actual stages of the declared receipt/configurationforeground productionper 1 kg reference flow

One integrated foreground unit is used because the same barrel passes through machining, shaping, testing and packing; there is one saleable reference output. Preserve this ordered physical stage map and the measured mass, water and carbon transfers independently of the environmental burden account. At a separately modelled stage boundary, both sides must link the same real intermediate, quantity, moisture and time; no fictitious second finished-barrel UUID or allocation-scaled transfer is permitted.

stage_idinclusionoperationphysical records
receiptrequiredWood receipt and stock reconciliationSpecies, split/sawn/seasoned state, lot mass and supplier coverage
seasoningconditionalNatural air seasoningRequired for green receipts; actual dates, air/rain, sprinkling, loss and water/energy logs; pre-seasoned purchases link upstream
machiningrequiredTrim, plane, hollow, joint staves; machine heads and groovesKeep wood yield, sawdust, shavings, offcuts, dust control and electricity by operation
bendingrequiredRosing, preheat and steam/fire bendingDeclare actual method; distinguish wetting, steam, fuel, internal/off-site heat and temperature/time history
toastingconditionalOenological toastingDeclare no-toast or actual toast label, temperature/time/oxygen and fuel; retained toasted layer differs from removed char
assemblyrequiredHead setting, permanent metal hoops and final sandingStave/head/hoop/bung net masses, temporary-tool reuse, actual purchased versus locally formed hoops
leak_testrequiredWater-tightness test and corrective reworkActual fill/pressure/duration/criterion, water reuse, reject and final acceptance; no default test volume
dispatchrequiredDrain, measure net mass, prepare and pack for dispatchAccepted count and mass Q, residual water, packaging separately and dispatch boundary
boilerconditionalOn-site steam generationOnly if actual boiler operates: feedwater, fuel, internal steam, condensate, blowdown, ash and separate stack monitoring

Process: New oak barrel production (new_barrel_production)

Inputs

Product flows
Green split oak cooperage blank (green_split_oak_blank)

Receive only untreated split oak blanks; weigh each compatible lot and retain species, split route, dimensions and moisture. This row does not cover sawn or pre-seasoned receipts.

  • Selected flow: Cleft timber 7f0b2ade-9ce4-4cbb-a05f-6a30d7fbf0cc
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_wood.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wood
  • Sources: seguin-process
Green rough-sawn oak board (green_sawn_oak_blank)

Only rough-sawn, undried oak boards thicker than 6 mm with grain and watertightness acceptance; record supplier route and upstream transport. Never substitute this record for split wood. The source names an upstream P3 intermediate at plant; actual supplier preparation, transport and gate compatibility remain pending, without replacing the declared untreated green >6 mm rough-sawn oak state.

  • Selected flow: Green non-coniferous sawnwood, rough-sawn e882cc86-ffc0-4470-8534-84fef54f20a0
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_wood.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wood
  • Sources: seguin-process
Air-seasoned rough oak cooperage blank (seasoned_oak_blank)

Actual untreated all-oak cooperage blanks received after natural air seasoning, separately from green receipt. Retain measured delivered moisture, dimensions, species and batch mass, verified upstream preparation/seasoning history and its water, losses and energy, and the supplier delivery boundary; do not repeat supplier seasoning at this site. The broad wood-material locator has no specified form, moisture, route or provider and does not establish an oak-specific background; quantity and provider compatibility remain pending.

  • Selected flow: Wood material d07bf4c9-7cd0-46ad-a6b3-2fd11fe08f98
  • Flow property / unit: Mass / kg

Identity support: flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_wood.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_wood
  • Sources: seguin-process
Seasoning pumps electricity (season_electricity)

Stage-specific metered low-voltage grid electricity when artificial sprinkling operates; this UUID is restricted to customer-side alternating current below 1 kV. Retain the meter boundary; attribute shared compressor/extraction demand once. The source geographic context is CN. Actual site/provider geography, supply mix and delivery/loss-boundary compatibility remain pending; the locator does not establish a universal electricity background.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value / MJ

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200c9a66; unit group 93a60a57-a3c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_resources.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_resources
  • Sources: seguin-process
Trimming, planing, jointing and head machining electricity (machining_electricity)

Stage-specific metered low-voltage grid electricity when machinery operates; this UUID is restricted to customer-side alternating current below 1 kV. Retain the meter boundary; attribute shared compressor/extraction demand once. The source geographic context is CN. Actual site/provider geography, supply mix and delivery/loss-boundary compatibility remain pending; the locator does not establish a universal electricity background.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value / MJ

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200c9a66; unit group 93a60a57-a3c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_resources.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_resources
  • Sources: seguin-process
Steam or mechanical bending auxiliaries electricity (bending_electricity)

Stage-specific metered low-voltage grid electricity when powered auxiliaries operate; this UUID is restricted to customer-side alternating current below 1 kV. Retain the meter boundary; attribute shared compressor/extraction demand once. The source geographic context is CN. Actual site/provider geography, supply mix and delivery/loss-boundary compatibility remain pending; the locator does not establish a universal electricity background.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value / MJ

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200c9a66; unit group 93a60a57-a3c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_resources.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_resources
  • Sources: seguin-process
Toasting controls or electric heaters electricity (toasting_electricity)

Stage-specific metered low-voltage grid electricity when electrical equipment operates; this UUID is restricted to customer-side alternating current below 1 kV. Retain the meter boundary; attribute shared compressor/extraction demand once. The source geographic context is CN. Actual site/provider geography, supply mix and delivery/loss-boundary compatibility remain pending; the locator does not establish a universal electricity background.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value / MJ

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200c9a66; unit group 93a60a57-a3c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_resources.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_resources
  • Sources: seguin-process
Hoop fitting and finish sanding electricity (hooping_electricity)

Stage-specific metered low-voltage grid electricity when powered equipment operates; this UUID is restricted to customer-side alternating current below 1 kV. Retain the meter boundary; attribute shared compressor/extraction demand once. The source geographic context is CN. Actual site/provider geography, supply mix and delivery/loss-boundary compatibility remain pending; the locator does not establish a universal electricity background.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value / MJ

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200c9a66; unit group 93a60a57-a3c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_resources.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_resources
  • Sources: seguin-process
Leak-test pump and compressor electricity (testing_electricity)

Stage-specific metered low-voltage grid electricity when powered test equipment operates; this UUID is restricted to customer-side alternating current below 1 kV. Retain the meter boundary; attribute shared compressor/extraction demand once. The source geographic context is CN. Actual site/provider geography, supply mix and delivery/loss-boundary compatibility remain pending; the locator does not establish a universal electricity background.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value / MJ

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200c9a66; unit group 93a60a57-a3c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_resources.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_resources
  • Sources: seguin-process
Drying after test and dispatch preparation electricity (packing_electricity)

Stage-specific metered low-voltage grid electricity when powered finishing equipment operates; this UUID is restricted to customer-side alternating current below 1 kV. Retain the meter boundary; attribute shared compressor/extraction demand once. The source geographic context is CN. Actual site/provider geography, supply mix and delivery/loss-boundary compatibility remain pending; the locator does not establish a universal electricity background.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value / MJ

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200c9a66; unit group 93a60a57-a3c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_resources.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_resources
  • Sources: seguin-process
On-site steam-generation auxiliaries electricity (boiler_electricity)

Stage-specific metered low-voltage grid electricity when an on-site boiler operates; this UUID is restricted to customer-side alternating current below 1 kV. Retain the meter boundary; attribute shared compressor/extraction demand once. The source geographic context is CN. Actual site/provider geography, supply mix and delivery/loss-boundary compatibility remain pending; the locator does not establish a universal electricity background.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value / MJ

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200c9a66; unit group 93a60a57-a3c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_resources.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_resources
  • Sources: seguin-process
Seasoning spray tap water (season_spray_water)

Record artificial sprinkling separately from rain and recirculated water.

  • Selected flow: Water, tap c6fb2442-d527-4e3d-bf01-4c94ea2b71ec
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_resources.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_resources
  • Sources: seguin-process
Bending wetting tap water (bending_water)

Record actual fire-bending wetting or immersion makeup.

  • Selected flow: Water, tap c6fb2442-d527-4e3d-bf01-4c94ea2b71ec
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_resources.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_resources
  • Sources: seguin-process
Leak-test tap water (test_water)

Meter fresh test makeup; re-used water is a circulation record, not a repeated freshwater input.

  • Selected flow: Water, tap c6fb2442-d527-4e3d-bf01-4c94ea2b71ec
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_resources.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_resources
  • Sources: taransaud-quality
Boiler makeup tap water (boiler_makeup_water)

Conditional on-site boiler input; reconcile steam, returned condensate, blowdown and losses.

  • Selected flow: Water, tap c6fb2442-d527-4e3d-bf01-4c94ea2b71ec
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_resources.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_resources
  • Sources: seguin-process
Purchased steam for oak stave bending (bending_purchased_steam)

Only external delivered steam mass. Record pressure, temperature, dryness, enthalpy and return conditions; keep its provider link unresolved until the supplier reference basis is compatible. Internal boiler steam is a stage ledger entry, not another external input.

  • Selected flow: Purchased steam for oak stave bending
  • Flow property / unit: Mass / kg
  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_heat.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_heat
  • Sources: seguin-toasts
Bending fire purchased non-coniferous fuel wood (bending_purchased_fuelwood)

Only separately purchased short logs or split billets meeting the non-coniferous fuel-wood record. Retain species, moisture, contamination and delivery route; internally consumed oak offcuts are tracked in the dry-wood ledger and receive no second upstream purchase. The source upstream gate is unprocessed fuelwood at forest roadside. Actual preparation, delivery/transport and provider compatibility remain pending; it does not cover internally generated factory offcut fuel.

  • Selected flow: Fuel wood of non-coniferous wood aaabc17f-c8db-4493-aa7d-1acb67ee3fa2
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_heat.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_heat
  • Sources: thermal-wood-2005
Bending fire natural gas (bending_natural_gas)

Conditional gaseous pipeline natural gas, reference Volume/m3. Match temperature, absolute pressure, wet/dry composition, compressibility and supplier background m3 definition before linking a quantity; secondary database mass coefficients are not density.

  • Selected flow: natural gas in the gaseous state 4f19ca0e-7b3b-11dd-ad8b-0800200c9a66
  • Flow property / unit: Volume / m3

Identity support:flow property 93a60a56-a3c8-22da-a746-0800200c9a66; unit group 93a60a57-a3c8-12da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_heat.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_heat
  • Sources: thermal-wood-2005
Toasting fire purchased non-coniferous fuel wood (toasting_purchased_fuelwood)

Only separately purchased short logs or split billets meeting the non-coniferous fuel-wood record. Retain species, moisture, contamination and delivery route; internally consumed oak offcuts are tracked in the dry-wood ledger and receive no second upstream purchase. The source upstream gate is unprocessed fuelwood at forest roadside. Actual preparation, delivery/transport and provider compatibility remain pending; it does not cover internally generated factory offcut fuel.

  • Selected flow: Fuel wood of non-coniferous wood aaabc17f-c8db-4493-aa7d-1acb67ee3fa2
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_heat.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_heat
  • Sources: thermal-wood-2005
Toasting fire natural gas (toasting_natural_gas)

Conditional gaseous pipeline natural gas, reference Volume/m3. Match temperature, absolute pressure, wet/dry composition, compressibility and supplier background m3 definition before linking a quantity; secondary database mass coefficients are not density.

  • Selected flow: natural gas in the gaseous state 4f19ca0e-7b3b-11dd-ad8b-0800200c9a66
  • Flow property / unit: Volume / m3

Identity support:flow property 93a60a56-a3c8-22da-a746-0800200c9a66; unit group 93a60a57-a3c8-12da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_heat.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_heat
  • Sources: thermal-wood-2005
On-site wood boiler purchased non-coniferous fuel wood (boiler_purchased_fuelwood)

Only separately purchased short logs or split billets meeting the non-coniferous fuel-wood record. Retain species, moisture, contamination and delivery route; internally consumed oak offcuts are tracked in the dry-wood ledger and receive no second upstream purchase. The source upstream gate is unprocessed fuelwood at forest roadside. Actual preparation, delivery/transport and provider compatibility remain pending; it does not cover internally generated factory offcut fuel.

  • Selected flow: Fuel wood of non-coniferous wood aaabc17f-c8db-4493-aa7d-1acb67ee3fa2
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_heat.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_heat
  • Sources: epa-wood-boilers
On-site wood boiler natural gas (boiler_natural_gas)

Conditional gaseous pipeline natural gas, reference Volume/m3. Match temperature, absolute pressure, wet/dry composition, compressibility and supplier background m3 definition before linking a quantity; secondary database mass coefficients are not density.

  • Selected flow: natural gas in the gaseous state 4f19ca0e-7b3b-11dd-ad8b-0800200c9a66
  • Flow property / unit: Volume / m3

Identity support:flow property 93a60a56-a3c8-22da-a746-0800200c9a66; unit group 93a60a57-a3c8-12da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_heat.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_heat
  • Sources: epa-wood-boilers
Finished black carbon-steel cooperage hoop (black_steel_hoop)

Only actual purchased closed permanent black carbon-steel barrel hoops. Measure installed mass including the actual coating and retain grade, recycled content, ring dimensions, forming/welding and supplier boundary; temporary working hoops remain tools with actual usage/replacement records. Generic Hoops names/comment describe circular hoops without a hard treatment route, while source CPC42946 concerns fencing/barbed or twisted hoop wire. Retain this unresolved classification ambiguity for source-owner/provider clarification; the locator does not establish exact finished-ring manufacture, coating recipe or background compatibility.

  • Selected flow: Hoops, unspecified 1b7aae9d-e2c8-4cbe-b979-4966170154e3
  • Flow property / unit: Mass / kg

Identity support: flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_parts.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_parts
  • Sources: seguin-process
Finished galvanized carbon-steel cooperage hoop (galvanized_steel_hoop)

Only actual purchased closed permanent galvanized carbon-steel barrel hoops. Measure installed mass including the actual zinc coating and retain grade, ring dimensions, forming/welding, coating and supplier boundary; do not invent additional zinc mass or substitute packaging straps. Generic Hoops names/comment describe circular hoops without a hard treatment route, while source CPC42946 concerns fencing/barbed or twisted hoop wire. Retain this unresolved classification ambiguity for source-owner/provider clarification; the locator does not establish exact finished-ring manufacture, galvanization recipe or background compatibility.

  • Selected flow: Hoops, unspecified 1b7aae9d-e2c8-4cbe-b979-4966170154e3
  • Flow property / unit: Mass / kg

Identity support: flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_parts.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_parts
  • Sources: seguin-process
Finished oak bung (oak_bung)

Only the actual finished all-oak bung supplied with an accepted barrel, measured separately and included in installed net mass. Retain dimensions, treatment state and fabrication/supplier boundary. The broad wood-material locator is not a confirmed bung-manufacturing background; quantity and provider compatibility remain pending. Silicone, cork, glued or composite closures require separate actual atomic rows/configuration.

  • Selected flow: Wood material d07bf4c9-7cd0-46ad-a6b3-2fd11fe08f98
  • Flow property / unit: Mass / kg

Identity support: flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_parts.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_parts
  • Sources: taransaud-quality
LDPE dispatch film (packaging_ldpe)

Conditional measured non-cellular, non-adhesive, unreinforced LDPE film. Keep transport packaging outside accepted barrel net mass; other wrapping polymers require their own atomic rows. This source film is also nonlaminated and unsupported; confirm the actual grade, thickness, physical form and provider boundary.

  • Selected flow: Low-density polyethylene foil (PE-LD) 2cecd3a7-d90e-44b4-aec5-1d9dfb907477
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_parts.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_parts
  • Sources: seguin-process

Outputs

Product flows
Accepted new oak wine barrel (accepted_new_oak_barrel)

1 kg accepted net complete new oak wine barrel, including installed permanent hoops and supplied bung, excluding transport packaging and residual leak-test water. This is the only reference-product output. The official Chinese baseName mistranslates cooperage as copperware; retain the official display but disclose pending source-owner translation clarification. The coherent English name, wood classification and container description support this qualified complete wooden barrel, not copper material.

  • Selected flow: Casks, barrels, vats, tubs and other coopers' products and parts thereof, of wood, including staves 8b100f0f-21c2-4373-b469-a67b4f87973e
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: 1 kg
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_acceptance
  • Sources: taransaud-quality
Untreated oak sawdust for sale (sold_sawdust)

Actual separately collected and sold untreated oak sawdust, with measured wet mass, moisture, dry mass/carbon and contamination state. Confirm lawful coproduct status, sales contract, customer-accepted specification, actual use and receiver; payment alone does not establish product status. Keep this physical stream separate from discarded wood, internal fuel and returned stock. The broad wood-material locator leaves form, moisture, route and provider unspecified; supplier/customer quantity and gate compatibility remain pending. Burden shares never scale physical output.

  • Selected flow: Wood material d07bf4c9-7cd0-46ad-a6b3-2fd11fe08f98
  • Flow property / unit: Mass / kg

Identity support: flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_residues.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_residues
  • Sources: corrim-allocation-case
Untreated oak planing shavings for sale (sold_shavings)

Actual separately collected and sold untreated oak planing shavings, with measured wet mass, moisture, dry mass/carbon and contamination state. Confirm lawful coproduct status, sales contract, customer-accepted specification, actual use and receiver; payment alone does not establish product status. Keep this physical stream separate from discarded wood, internal fuel and returned stock. The broad wood-material locator leaves form, moisture, route and provider unspecified; supplier/customer quantity and gate compatibility remain pending. Burden shares never scale physical output.

  • Selected flow: Wood material d07bf4c9-7cd0-46ad-a6b3-2fd11fe08f98
  • Flow property / unit: Mass / kg

Identity support: flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_residues.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_residues
  • Sources: corrim-allocation-case
Untreated oak uncompacted offcuts for sale (sold_offcuts)

Actual separately collected and sold untreated oak non-agglomerated solid offcuts, with measured wet mass, moisture, dry mass/carbon and contamination state. Confirm lawful coproduct status, sales contract, customer-accepted specification, actual use and receiver; payment alone does not establish product status. Keep this physical stream separate from discarded wood, internal fuel and returned stock. The broad wood-material locator leaves form, moisture, route and provider unspecified; supplier/customer quantity and gate compatibility remain pending. Burden shares never scale physical output.

  • Selected flow: Wood material d07bf4c9-7cd0-46ad-a6b3-2fd11fe08f98
  • Flow property / unit: Mass / kg

Identity support: flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_residues.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_residues
  • Sources: corrim-allocation-case
Waste flows
Discarded untreated oak sawdust (discarded_sawdust)

Only discarded collected sawdust leaving the unit, not sold sawdust, emitted PM or internally burned fuel. The source route is untreated for combustion/recycling: retain this adoption only for an actual compatible receiving route, with receiver evidence. Unknown or different destinations remain unresolved; do not infer fuel credits or actual treatment emissions.

  • Selected flow: sawdust waste e1a44d20-d968-4d64-bd7c-253a1441ab35
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_residues.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_residues
  • Sources: seguin-process
Discarded untreated oak planing shavings (discarded_shavings)

Actual separately collected non-agglomerated untreated oak planing shavings, independently weighed with measured moisture, material/contamination state and actual receiver. Broad Wood waste names/synonyms/comment include wood residues and its primary-production route is compatible with manufacturing residues; source CPC39282 agglomeration conflicts with this physical description. Retain unresolved source classification/receiver/provider clarification, not an exact agglomeration or treatment claim. Exclude sold coproducts, internal fuel/returns, stack particles and separated char; do not import the source municipal-waste percentages.

  • Selected flow: Wood waste 2ef9d37a-2fbf-42f6-8ccf-5d6677d5cfd8
  • Flow property / unit: Mass / kg

Identity support: flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_residues.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_residues
  • Sources: seguin-process
Discarded uncompacted oak offcuts (discarded_offcuts)

Weigh actual non-agglomerated oak pieces with glue/chemical contamination explicitly absent or characterized and a declared receiving operator. This is conditional physical identity use; the source classification conflict remains unresolved.

  • Selected flow: Offcut acc22294-8e77-4784-988f-2499be3c60eb
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_residues.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_residues
  • Sources: seguin-process
Rejected new oak barrel (rejected_barrel)

Only a rejected complete barrel leaving the unit; separate recovered hoops from wood if dismantled. Internal repair consumes resources but is not a second reference output.

  • Selected flow: Rejected new oak barrel
  • Flow property / unit: Mass / kg
  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_residues.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_residues
  • Sources: taransaud-quality
Collected oak seasoning runoff (season_runoff)

Measure collected leachate sent to treatment; separate rainfall, spray water and wood-extractive load. This is not a direct natural-water discharge.

  • Selected flow: Collected oak seasoning runoff
  • Flow property / unit: Mass / kg
  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_residues.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_residues
  • Sources: seguin-process
Untreated barrel leak-test wastewater (test_wastewater)

Measure exported test water after reuse; retain contamination, receiving treatment and all actual additives.

  • Selected flow: Untreated barrel leak-test wastewater
  • Flow property / unit: Mass / kg
  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_residues.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_residues
  • Sources: taransaud-quality
Wood-fire bottom ash (thermal_bottom_ash)

Separately collected actual inorganic bottom ash from wood fuel used in bending or toasting, with measured mass, fuel/source, inorganic composition, unburned carbon, moisture, contamination/hazard state and receiver. The generic ash locator has no opposing source/route but establishes no wood-fuel treatment background; quantity and provider compatibility remain pending. Keep sorted char, retained barrel toast layer, captured fly ash and stack particles separate.

  • Selected flow: ash d74120f1-379f-4d45-a254-c2fd0b3f05e2
  • Flow property / unit: Mass / kg

Identity support: flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_residues.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_residues
  • Sources: thermal-wood-2005
Separated oak char residue (thermal_char)

Only removed char, not the retained toasted layer in the barrel. Record carbon, destination and combustion if subsequently burned.

  • Selected flow: Separated oak char residue
  • Flow property / unit: Mass / kg
  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_residues.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_residues
  • Sources: thermal-wood-2005
Wood-boiler bottom ash (boiler_bottom_ash)

Only separately collected actual inorganic bottom ash from the on-site wood-fuel boiler, with measured mass, fuel/source, inorganic composition, unburned carbon, moisture, contamination/hazard state and receiver. The generic ash locator has no opposing source/route but establishes no boiler-specific treatment background; quantity and provider compatibility remain pending. Keep sorted char, captured fly ash and stack particles separate.

  • Selected flow: ash d74120f1-379f-4d45-a254-c2fd0b3f05e2
  • Flow property / unit: Mass / kg

Identity support: flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_residues.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_residues
  • Sources: epa-wood-boilers
Collected wood-boiler fly ash (boiler_fly_ash)

Only actual wood-boiler ash captured and removed by a flue-gas purification control device, matching the source flow treatment route. Measure collected mass and retain fuel, device, inorganic chemistry, unburned carbon, moisture/contamination and receiver/provider boundary. Captured ash is neither stack particulate emissions nor bottom ash or machining dust; actual treatment and provider quantity compatibility remain pending.

  • Selected flow: dust collector ash 2802116a-dd90-4bad-a456-5afe7d7fa1d6
  • Flow property / unit: Mass / kg

Identity support: flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_residues.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_residues
  • Sources: epa-wood-boilers
Untreated boiler blowdown water (boiler_blowdown)

Conditional on-site boiler exported blowdown; identify dissolved solids and destination.

  • Selected flow: Untreated boiler blowdown water
  • Flow property / unit: Mass / kg
  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_residues.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_residues
  • Sources: epa-wood-boilers
Hoop-fitting steel scrap (hoop_steel_scrap)

Conditional scrap from on-site metal fitting, unprocessed at plant; record actual steel grade and recycling recipient.

  • Selected flow: Post-industrial steel scrap c143745d-be4f-4d8f-b403-2dcbfe685349
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_residues.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_residues
  • Sources: seguin-process
Unprocessed waste LDPE film (packing_film_scrap)

Only production wrapping offcuts or rejects, not downstream packaging disposal; state contamination and treatment.

  • Selected flow: Unprocessed waste LDPE film
  • Flow property / unit: Mass / kg
  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_residues.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_residues
  • Sources: seguin-process
Elementary flows

All elementary emission cards below refer to outdoor air, unspecified subcompartment. Use a matching verified subclass if the site establishes urban ground-level, high-stack or another receiving condition; these records cannot be substituted for indoor workplace exposure. Source stage and outlet remain distinct collection fields; a shared thermal hood must not be counted once for every stage it serves.

Seasoning water vapour (season_water_vapour)

Calculate evaporated water from the corrected water balance, retaining rain, spray, runoff and inventory change; wet-mass loss alone also contains dry-material loss.

  • Selected flow: water vapour fe0acd60-3ddc-11dd-ac04-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_balance.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_balance
  • Sources: usda-wood-2021
Post-test drying water vapour (test_drying_vapour)

Account for water lost after leak testing; it is excluded from accepted net barrel mass.

  • Selected flow: water vapour fe0acd60-3ddc-11dd-ac04-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_balance.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_balance
  • Sources: usda-wood-2021
Machining PM2.5 (machining_pm25)

Measure the emitted size fraction after actual controls, with outlet, aerodynamic size definition and filterable/condensable coverage. Size bins must be disjoint; do not add total PM or cumulative PM10 again, and never derive kg from visible smoke or captured dust.

  • Selected flow: particles (PM2.5) 08a91e70-3ddc-11dd-9293-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: epa-sawmill-pte-scope
Machining PM2.5 to PM10 fraction (machining_pm_between)

Measure the emitted size fraction after actual controls, with outlet, aerodynamic size definition and filterable/condensable coverage. Size bins must be disjoint; do not add total PM or cumulative PM10 again, and never derive kg from visible smoke or captured dust.

  • Selected flow: particles (PM2.5 - PM10) 08a91e70-3ddc-11dd-9501-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: epa-sawmill-pte-scope
Machining PM above 10 micrometres (machining_pm_coarse)

Measure the emitted size fraction after actual controls, with outlet, aerodynamic size definition and filterable/condensable coverage. Size bins must be disjoint; do not add total PM or cumulative PM10 again, and never derive kg from visible smoke or captured dust.

  • Selected flow: particles (> PM10) fe0acd60-3ddc-11dd-a70a-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: epa-sawmill-pte-scope
Bending and toasting exhaust PM2.5 (thermal_pm25)

Measure the emitted size fraction after actual controls, with outlet, aerodynamic size definition and filterable/condensable coverage. Size bins must be disjoint; do not add total PM or cumulative PM10 again, and never derive kg from visible smoke or captured dust.

  • Selected flow: particles (PM2.5) 08a91e70-3ddc-11dd-9293-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: thermal-wood-2005
Bending and toasting exhaust PM2.5 to PM10 fraction (thermal_pm_between)

Measure the emitted size fraction after actual controls, with outlet, aerodynamic size definition and filterable/condensable coverage. Size bins must be disjoint; do not add total PM or cumulative PM10 again, and never derive kg from visible smoke or captured dust.

  • Selected flow: particles (PM2.5 - PM10) 08a91e70-3ddc-11dd-9501-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: thermal-wood-2005
Bending and toasting exhaust PM above 10 micrometres (thermal_pm_coarse)

Measure the emitted size fraction after actual controls, with outlet, aerodynamic size definition and filterable/condensable coverage. Size bins must be disjoint; do not add total PM or cumulative PM10 again, and never derive kg from visible smoke or captured dust.

  • Selected flow: particles (> PM10) fe0acd60-3ddc-11dd-a70a-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: thermal-wood-2005
On-site boiler exhaust PM2.5 (boiler_pm25)

Measure the emitted size fraction after actual controls, with outlet, aerodynamic size definition and filterable/condensable coverage. Size bins must be disjoint; do not add total PM or cumulative PM10 again, and never derive kg from visible smoke or captured dust.

  • Selected flow: particles (PM2.5) 08a91e70-3ddc-11dd-9293-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: epa-wood-boilers
On-site boiler exhaust PM2.5 to PM10 fraction (boiler_pm_between)

Measure the emitted size fraction after actual controls, with outlet, aerodynamic size definition and filterable/condensable coverage. Size bins must be disjoint; do not add total PM or cumulative PM10 again, and never derive kg from visible smoke or captured dust.

  • Selected flow: particles (PM2.5 - PM10) 08a91e70-3ddc-11dd-9501-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: epa-wood-boilers
On-site boiler exhaust PM above 10 micrometres (boiler_pm_coarse)

Measure the emitted size fraction after actual controls, with outlet, aerodynamic size definition and filterable/condensable coverage. Size bins must be disjoint; do not add total PM or cumulative PM10 again, and never derive kg from visible smoke or captured dust.

  • Selected flow: particles (> PM10) fe0acd60-3ddc-11dd-a70a-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: epa-wood-boilers
Bending and toasting biogenic carbon dioxide (thermal_co2_bio)

Measure or calculate actual atmospheric release by outlet and source stage. Separate fuel combustion from thermal degradation of barrel wood; verify biogenic/fossil origin, abatement and startup/shutdown. Absence requires documented route or detection-limit evidence, not an assumed zero. Retain biogenic CO2 in LCI regardless of greenhouse-gas statistical exclusions; no automatic carbon-neutral or storage credit.

  • Selected flow: carbon dioxide (biogenic) 08a91e70-3ddc-11dd-9c15-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: thermal-wood-2005
Bending and toasting fossil carbon dioxide (thermal_co2_fossil)

Measure or calculate actual atmospheric release by outlet and source stage. Separate fuel combustion from thermal degradation of barrel wood; verify biogenic/fossil origin, abatement and startup/shutdown. Absence requires documented route or detection-limit evidence, not an assumed zero.

  • Selected flow: carbon dioxide (fossil) 08a91e70-3ddc-11dd-923d-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: thermal-wood-2005
Bending and toasting biogenic carbon monoxide (thermal_co_bio)

Measure or calculate actual atmospheric release by outlet and source stage. Separate fuel combustion from thermal degradation of barrel wood; verify biogenic/fossil origin, abatement and startup/shutdown. Absence requires documented route or detection-limit evidence, not an assumed zero.

  • Selected flow: carbon monoxide (biogenic) 8a313a02-e251-11e6-bf01-fe55135034f3
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: thermal-wood-2005
Bending and toasting fossil carbon monoxide (thermal_co_fossil)

Measure or calculate actual atmospheric release by outlet and source stage. Separate fuel combustion from thermal degradation of barrel wood; verify biogenic/fossil origin, abatement and startup/shutdown. Absence requires documented route or detection-limit evidence, not an assumed zero.

  • Selected flow: carbon monoxide (fossil) 08a91e70-3ddc-11dd-924e-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: thermal-wood-2005
Bending and toasting biogenic methane (thermal_ch4_bio)

Measure or calculate actual atmospheric release by outlet and source stage. Separate fuel combustion from thermal degradation of barrel wood; verify biogenic/fossil origin, abatement and startup/shutdown. Absence requires documented route or detection-limit evidence, not an assumed zero.

  • Selected flow: methane (biogenic) fe0acd60-3ddc-11dd-a8e8-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: thermal-wood-2005
Bending and toasting fossil methane (thermal_ch4_fossil)

Measure or calculate actual atmospheric release by outlet and source stage. Separate fuel combustion from thermal degradation of barrel wood; verify biogenic/fossil origin, abatement and startup/shutdown. Absence requires documented route or detection-limit evidence, not an assumed zero.

  • Selected flow: methane (fossil) 08a91e70-3ddc-11dd-9610-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: thermal-wood-2005
Bending and toasting nitrous oxide (thermal_n2o)

Measure or calculate actual atmospheric release by outlet and source stage. Separate fuel combustion from thermal degradation of barrel wood; verify biogenic/fossil origin, abatement and startup/shutdown. Absence requires documented route or detection-limit evidence, not an assumed zero.

  • Selected flow: nitrous oxide 08a91e70-3ddc-11dd-94c3-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: thermal-wood-2005
Bending and toasting nitrogen oxides (thermal_nox)

Measure or calculate actual atmospheric release by outlet and source stage. Separate fuel combustion from thermal degradation of barrel wood; verify biogenic/fossil origin, abatement and startup/shutdown. Absence requires documented route or detection-limit evidence, not an assumed zero. NOx excludes N2O; do not also inventory constituent NO/NO2. Mass/kg does not prove NO2-equivalent quantity: monitoring, LCI record and LCIA definitions must agree before use.

  • Selected flow: Nitrogen oxides f79d0f8f-2b0e-49cb-bed0-b1ea0fbd8625
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: thermal-wood-2005
Bending and toasting sulfur dioxide (thermal_so2)

Measure or calculate actual atmospheric release by outlet and source stage. Separate fuel combustion from thermal degradation of barrel wood; verify biogenic/fossil origin, abatement and startup/shutdown. Absence requires documented route or detection-limit evidence, not an assumed zero.

  • Selected flow: sulfur dioxide fe0acd60-3ddc-11dd-ac48-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: thermal-wood-2005
On-site boiler biogenic carbon dioxide (boiler_co2_bio)

Measure or calculate actual atmospheric release by outlet and source stage. Separate fuel combustion from thermal degradation of barrel wood; verify biogenic/fossil origin, abatement and startup/shutdown. Absence requires documented route or detection-limit evidence, not an assumed zero. Retain biogenic CO2 in LCI regardless of greenhouse-gas statistical exclusions; no automatic carbon-neutral or storage credit.

  • Selected flow: carbon dioxide (biogenic) 08a91e70-3ddc-11dd-9c15-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: epa-wood-boilers
On-site boiler fossil carbon dioxide (boiler_co2_fossil)

Measure or calculate actual atmospheric release by outlet and source stage. Separate fuel combustion from thermal degradation of barrel wood; verify biogenic/fossil origin, abatement and startup/shutdown. Absence requires documented route or detection-limit evidence, not an assumed zero.

  • Selected flow: carbon dioxide (fossil) 08a91e70-3ddc-11dd-923d-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: epa-wood-boilers
On-site boiler biogenic carbon monoxide (boiler_co_bio)

Measure or calculate actual atmospheric release by outlet and source stage. Separate fuel combustion from thermal degradation of barrel wood; verify biogenic/fossil origin, abatement and startup/shutdown. Absence requires documented route or detection-limit evidence, not an assumed zero.

  • Selected flow: carbon monoxide (biogenic) 8a313a02-e251-11e6-bf01-fe55135034f3
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: epa-wood-boilers
On-site boiler fossil carbon monoxide (boiler_co_fossil)

Measure or calculate actual atmospheric release by outlet and source stage. Separate fuel combustion from thermal degradation of barrel wood; verify biogenic/fossil origin, abatement and startup/shutdown. Absence requires documented route or detection-limit evidence, not an assumed zero.

  • Selected flow: carbon monoxide (fossil) 08a91e70-3ddc-11dd-924e-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: epa-wood-boilers
On-site boiler biogenic methane (boiler_ch4_bio)

Measure or calculate actual atmospheric release by outlet and source stage. Separate fuel combustion from thermal degradation of barrel wood; verify biogenic/fossil origin, abatement and startup/shutdown. Absence requires documented route or detection-limit evidence, not an assumed zero.

  • Selected flow: methane (biogenic) fe0acd60-3ddc-11dd-a8e8-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: epa-wood-boilers
On-site boiler fossil methane (boiler_ch4_fossil)

Measure or calculate actual atmospheric release by outlet and source stage. Separate fuel combustion from thermal degradation of barrel wood; verify biogenic/fossil origin, abatement and startup/shutdown. Absence requires documented route or detection-limit evidence, not an assumed zero.

  • Selected flow: methane (fossil) 08a91e70-3ddc-11dd-9610-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: epa-wood-boilers
On-site boiler nitrous oxide (boiler_n2o)

Measure or calculate actual atmospheric release by outlet and source stage. Separate fuel combustion from thermal degradation of barrel wood; verify biogenic/fossil origin, abatement and startup/shutdown. Absence requires documented route or detection-limit evidence, not an assumed zero.

  • Selected flow: nitrous oxide 08a91e70-3ddc-11dd-94c3-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: epa-wood-boilers
On-site boiler nitrogen oxides (boiler_nox)

Measure or calculate actual atmospheric release by outlet and source stage. Separate fuel combustion from thermal degradation of barrel wood; verify biogenic/fossil origin, abatement and startup/shutdown. Absence requires documented route or detection-limit evidence, not an assumed zero. NOx excludes N2O; do not also inventory constituent NO/NO2. Mass/kg does not prove NO2-equivalent quantity: monitoring, LCI record and LCIA definitions must agree before use.

  • Selected flow: Nitrogen oxides f79d0f8f-2b0e-49cb-bed0-b1ea0fbd8625
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: epa-wood-boilers
On-site boiler sulfur dioxide (boiler_so2)

Measure or calculate actual atmospheric release by outlet and source stage. Separate fuel combustion from thermal degradation of barrel wood; verify biogenic/fossil origin, abatement and startup/shutdown. Absence requires documented route or detection-limit evidence, not an assumed zero.

  • Selected flow: sulfur dioxide fe0acd60-3ddc-11dd-ac48-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: epa-wood-boilers
Toasting Methanol (thermal_methanol)

A conditional species to assess in the thermal-degradation exhaust, not a presumed positive emission. Sample actual escaped species after any combustion/control; source pyrolysate percentages and aroma retained in wood are not air-emission factors.

  • Selected flow: methanol fe0acd60-3ddc-11dd-a935-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: thermal-wood-2005
Toasting Acetaldehyde (thermal_acetaldehyde)

A conditional species to assess in the thermal-degradation exhaust, not a presumed positive emission. Sample actual escaped species after any combustion/control; source pyrolysate percentages and aroma retained in wood are not air-emission factors.

  • Selected flow: acetaldehyde fe0acd60-3ddc-11dd-a7a5-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: thermal-wood-2005
Toasting Acrolein (thermal_acrolein)

A conditional species to assess in the thermal-degradation exhaust, not a presumed positive emission. Sample actual escaped species after any combustion/control; source pyrolysate percentages and aroma retained in wood are not air-emission factors.

  • Selected flow: acrolein 08a91e70-3ddc-11dd-91a4-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: thermal-wood-2005
Toasting Acetic acid (thermal_acetic)

A conditional species to assess in the thermal-degradation exhaust, not a presumed positive emission. Sample actual escaped species after any combustion/control; source pyrolysate percentages and aroma retained in wood are not air-emission factors.

  • Selected flow: acetic acid 08a91e70-3ddc-11dd-92c3-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: thermal-wood-2005
Boiler Formaldehyde (boiler_formaldehyde)

Conditional wood-boiler species assessment supported by AP-42 Table 1.6-3. Use site measurements or a demonstrably matching boiler/fuel/control factor and uncertainty, never transfer a boiler factor to the open toasting fire.

  • Selected flow: formaldehyde 08a91e70-3ddc-11dd-941b-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: epa-wood-boilers
Boiler Acetaldehyde (boiler_acetaldehyde)

Conditional wood-boiler species assessment supported by AP-42 Table 1.6-3. Use site measurements or a demonstrably matching boiler/fuel/control factor and uncertainty, never transfer a boiler factor to the open toasting fire.

  • Selected flow: acetaldehyde fe0acd60-3ddc-11dd-a7a5-0050c2490048
  • Flow property / unit: Mass / kg

Identity support:flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_air.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_air
  • Sources: epa-wood-boilers
Bending and toasting water vapour (thermal_water_vapour)

Outdoor-air emission, unspecified subtype. Reconcile water evaporated from wood, fuel and applied water with separately evidenced chemical water formed during combustion; keep boiler/thermal outlets separate and do not re-use the seasoning or post-test evaporation total.

  • Selected flow: water vapour fe0acd60-3ddc-11dd-ac04-0050c2490048
  • Flow property / unit: Mass / kg

Identity support: flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_balance.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_balance
  • Sources: thermal-wood-2005
On-site boiler water vapour (boiler_water_vapour)

Outdoor-air emission, unspecified subtype. Reconcile water evaporated from wood, fuel and applied water with separately evidenced chemical water formed during combustion; keep boiler/thermal outlets separate and do not re-use the seasoning or post-test evaporation total.

  • Selected flow: water vapour fe0acd60-3ddc-11dd-ac04-0050c2490048
  • Flow property / unit: Mass / kg

Identity support: flow property 93a60a56-a3c8-11da-a746-0800200b9a66; unit group 93a60a57-a4c8-11da-a746-0800200c9a66

  • Amount rule: Collected actual exchange per 1 kg reference flow using cp_balance.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_balance
  • Sources: epa-wood-boilers

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 4
Rule IDApplies toRuleSource IDs
boundary_statesnew_barrel_productionRetain separate rough/seasoned/stave-shell/complete-barrel states and all actually executed stages. Model the integrated cooperage unit from receipt through accepted dispatch once; stage transfers are metered internal ledgers, not extra reference outputs.seguin-process, taransaud-quality
boundary_thermalthermal and boiler stagesDistinguish bending heat from sensory toast, direct fuel burning from degradation of retained oak, and separate boiler outlets. Use EPA boiler evidence only for a matching actual boiler; open fires require their own site emission evidence.seguin-toasts, thermal-wood-2005, epa-wood-boilers
boundary_materialall inventory rowsInclude actual raw materials, utility use, rejects, wastewater, wastes and emissions. A UUID gap does not authorize omitting a physically present flow; preserve a concrete atomic exchange and provider/identity gap. Document any actual treatment additive, adhesive, oil, packaging component or direct natural-water release with its own row before completeness.usda-wood-2021, taransaud-quality
boundary_carbonwood and air outputsKeep dry wood, retained toasted-layer carbon, exported residues, collected char/ash carbon and emitted chemical carbon as a reconciled physical account; retain biogenic CO2 in LCI. Upstream forest uptake is counted once in the linked boundary and not inferred as a negative cooperage emission.usda-wood-2021, thermal-wood-2005, epa-wood-boilers
Allocation rules · 4
Rule IDApplies toRuleSource IDs
allocation_directnew_barrel_productionFirst use measured subdivision or causal direct attribution. Finishing, leak tests, permanent hoops and barrel-only packaging belong to the barrel. Saleable wood coproducts are identified by actual destination/contract; waste disposition alone does not establish a coproduct.corrim-allocation-case, taransaud-quality
allocation_physical_ledgerall inventory rowsMaintain the complete unallocated physical stage, dry-mass/water/carbon ledger. Internal offcut fuel is accounted once with matching produced and consumed mass and moisture. Whole-unit internal transfers cancel; do not assign avoided upstream fuel burden or duplicate purchases without a separately declared substitution scenario.usda-wood-2021, thermal-wood-2005
allocation_shared_burdenshared environmental burdensIf unavoidable shared burdens remain, justify a site-specific physical causal relationship for eligible coproducts; report the eligible masses and shares. If no physical relationship can be defended, justify economic attribution using same-period net revenues and test an alternative. The softwood case supplies no oak cooperage allocation share or default method.corrim-allocation-case
allocation_no_mass_scalingcoproduct outputs and internal linksApply allocation shares only to the burden account, never multiply actual barrel/coproduct output quantities, residual carbon, internal wood transfers or measured water by a share. Keep the full physical ledger alongside the allocated product dataset; reconcile that ledger rather than demanding mass closure in the reduced burden ledger.usda-wood-2021, corrim-allocation-case
Validation rules · 7
Rule IDApplies toRuleSource IDs
validate_scopereference flowRequire new unused all-oak wine-barrel identity, finished completeness and leak acceptance; reject stave-only, refurbished or unqualified different toast/service configurations. UUID inclusion does not resolve background applicability.taransaud-quality, seguin-toasts
validate_denominatorall inventory rowsExactly one accepted_new_oak_barrel reference output is 1 kg and every exchange uses the same stock-corrected Q denominator. Keep stages distinct, prevent duplicate product outputs and audit all internal links for equal physical quantity.usda-wood-2021
validate_flowsall inventory rowsVerify exact physical/chemical identity against name, CAS, route, current classification, reference property and unit; a conflicting species/CAS or hard treatment/route blocks adoption even if a name looks right. An isolated source-classification error may permit conditional use of a coherent physical identity only with an explicit metadata debt, actual material/state/provider verification and source-owner clarification; it is not complete metadata validation. Each row is atomic, with exact Chinese baseName when provided; blank UUIDs retain their concrete exchange and missing-identity disclosure.usda-wood-2021
validate_energyall utility rowsRequire measured delivered energy/volume/mass on a supplier-compatible basis. Distinguish purchased steam from internal boiler heat, apply kWh/MJ conversion only to electric energy, and leave gas/steam basis compatibility pending when unknown.epa-wood-boilers
validate_emissionsall elementary outputsRequire outlet/medium, actual escaped species, carbon origin and quantity-definition evidence. Verify NOx convention excluding N2O, disjoint PM and filterable/condensable scope. Do not substitute correction flows or equate visible smoke with a PM mass; preserve biogenic CO2 despite GHG-reporting conventions.thermal-wood-2005, epa-wood-boilers, epa-sawmill-pte-scope
validate_closurephysical ledger and allocationReconcile dry material, water, biogenic/fossil carbon and all measured destinations with stock changes and uncertainty; retain unexplained residuals. Review allocation against the full unallocated physical ledger and the separately allocated burden ledger; do not change coproduct mass to close allocated burdens.usda-wood-2021, corrim-allocation-case
validate_completenessdataset profileBefore a complete cradle-to-gate dataset claim, resolve physically present UUID/provider gaps and all route quantities, add actual unlisted atomic flows and treatment releases, disclose skipped checks and uncertainty, and verify all required qualifiers. PCR authored status does not prove site-data or independent methodology approval.taransaud-quality, usda-wood-2021
Processes and inputs/outputs · 1
Process IDProcess nameInput flowsOutput flows
new_barrel_productionNew oak wine barrel production2654

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page