TianGong PCR

Peroxide–propylene glycol surface disinfectant: supplied liquid from purchased-reagent blending

Lifecycle status
Candidate
Content maturity
Authored methodology
Current version
0.1.0Last updated
Readiness
Review required

Methodology and translation states come from the source record; publishing this website does not change their review status.

Content languages

en-US · canonicalzh-CN · Aligned
Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:34664 · narrower

Source

1. Scope and Applicability

This PCR covers one physically blended aqueous surface-disinfectant route: purchased aqueous hydrogen peroxide, propylene glycol, orthophosphoric acid, sodium laureth sulfate, maleic acid, benzotriazole and separately added water. Sequential dilution and mixing produce an accepted supplied liquid at the blending-site gate, before downstream application. It is a narrower method within CPC 34664, not a method for every disinfectant. The patent establishes an example route, not commercial operating data. Actual formulation revision, assayed supplied state and product qualification define each dataset.

Exclude agricultural crop/seed fungicides, herbicides, insecticides, residual pesticide preparations, hand antiseptics, wipes, gels, peracetic-acid synthesis, chlorine formulations and upstream peroxide manufacture. The selected route uses purchased treated water and electrically driven mixing/transfer; no reaction synthesis, heating, combustion or packaged delivery is presumed. Additional actual ingredients, water treatment, heating/cooling, packaging, fuel or treatment operations require individually evidenced atomic additions before an extended dataset is used. No default concentration, kill rate, application rate, exposure, service life, emission factor or density is supplied.

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.other-transportable-goods-except-metal-products-machinery-and-equipment.basic-chemicals.disinfectants
classification_refsCPC 3.0 34664 Disinfectants; narrower
covered_productsAqueous peroxide–propylene glycol surface-disinfectant liquid of the selected ingredient set
excluded_productsAgricultural fungicides; handrub; chlorine products; peracetic acid; bulk upstream peroxide; packaged articles
representative_productNet supplied liquid with actual qualified composition and released batch identity
production_routePurchased-reagent sequential dilution and physical mixing, quality release, holding and bulk transfer
market_stateUnpackaged bulk liquid, as supplied at blending-site gate; actual concentration and temperature declared

3. Reference Flow

FieldValue
WhatSupply a qualified surface-disinfectant formulation
How much1 kg net supplied liquid
How wellActual product specification and label-supported claims; kg output alone is not a disinfection-service equivalence
How long or cycleOne supplied batch at release; no default use duration or shelf life
reference_flow_linkfinished_liquid
FieldValue
Reference amount1
Reference product flowDisinfectant 93328a0a-7cd1-4f63-831b-e9ac5398506e
Reference flow propertyMass 93a60a56-a3c8-11da-a746-0800200b9a66
Reference unit groupUnits of mass 93a60a57-a4c8-11da-a746-0800200c9a66
Reference unitkg
Required qualifiersactual ingredient identities and supplied forms; formulation revision; assayed active and water basis; supplier grade and route; site and reporting period; accepted supplied state; bulk transfer point; qualification and label limits; WIP and rework genealogy; upstream provider basis

The generic native identity is Product flow / Mass, production mix at plant, with no specified geography, CAS, concentration, recipe or manufacturing route. Its inert-surface meaning is compatible with this conditional supplied formulation; its broad statement about killing 99.999% is not accepted as product performance. The UUID supplies identity only, not a background provider or whole-liquid formulation specification. Required qualifiers must be present in the dataset; missing qualifiers make its reference definition incomplete.

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
reference_massreference productMass 93a60a56-a3c8-11da-a746-0800200b9a66kgUse net mass of the whole accepted supplied liquid, including its water and solvents, excluding storage vessel and packaging. Active-ingredient mass is a separate subledger.
single_basisall inventory denominatorsMasskgNormalize converted raw totals once to the same positive accepted supplied kg; keep actual numerator units. Never treat a concentration fraction as liquid mass or an integrated volume as a flow rate.

5. System Boundary

Boundary Abstraction

FieldValue
declared_starting_conditionSeparately purchased reagents and treated water received at blending site; incoming composition and carried inventory burdens recorded
starting_condition_rolePurchased ingredients, not on-site synthesis or generic same-category shortcuts
product_classification_scopeCPC 3.0 34664; narrower surface-disinfectant formulation
recursive_input_ruleA purchased preformulated disinfectant is one complete solution input with its own upstream burden. It is not decomposed into duplicate procurement; replacing the selected ingredient route requires explicit boundary reassessment.
upstream_dataset_requirementMatch actual supplied reagent/solution, concentration basis, grade, route, geography and delivery; pure-active providers require explicit carrier and burden reconciliation
disclosureState cut-offs, transport interface, bulk delivery, laboratory/services, cleaning, losses, shared-service allocation and all WIP burden transfers
rule_idapplies_torulesource_ids
boundary_routeblendInclude receiving, storage, sequential dilution/mixing, analytical release, holding, cleaning and transfer with all associated real burdens; physical mixing is not chemical synthesis.cn113491268-blending
boundary_scopereference productExclude agricultural crop/seed protection and upstream bulk chemicals from this foreground scope; retain their applicable upstream burdens rather than silently omitting them.un-cpc3-2025; wco-disinfectants-2022
boundary_usereference productDownstream application, exposure and environmental fate are outside this production inventory. Any such model needs separate actual-use evidence and separately qualified emissions.nhc-low-temperature-2020

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
blendPurchased-reagent blending and bulk supplyrequiredSelected ingredient route only; actual site operations evidencedforegroundfinished_liquid

Process: Purchased-reagent blending and bulk supply (blend)

Inputs

Product flows
Purchased aqueous peroxide reagent (peroxide_solution)

Record the complete supplied solution crossing the boundary, with actual assay and stabilizer/impurity composition. Neither a pure-H2O2 identity nor a fixed-strength catalogue record establishes the whole-solution procurement basis; retain an unbound specific solution row until its basis is verified. Active peroxide and carrier water are subledgers, never additional purchased flows.

  • Selected flow: Aqueous hydrogen peroxide reagent
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Actual attributable converted raw-period amount divided once by positive newly accepted supplied net kg, as specified in section 8.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_material
  • Sources: cn113491268-blending
Propylene glycol charge (propylene_glycol)

Record separately acquired propylene glycol, actual isomer/grade, assay and any water. A generic antifreeze, propylene carbonate or propylene oxide is not this exchange.

  • Selected flow: Propylene glycol
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Actual attributable converted raw-period amount divided once by positive newly accepted supplied net kg, as specified in section 8.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_material
  • Sources: cn113491268-blending
Phosphoric acid reagent (phosphoric_solution)

Record actual supplied acid solution mass and assay, not a dry P2O5 or nutrient equivalent. No assumed 85% concentration, wet/furnace process, or default impurity allowance. Include reagent water only in its subledger.

  • Selected flow: Aqueous orthophosphoric acid reagent
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Actual attributable converted raw-period amount divided once by positive newly accepted supplied net kg, as specified in section 8.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_material
  • Sources: cn113491268-blending
Sodium laureth sulfate ingredient (sles)

Use the actual supplied SLES grade with alkyl distribution, ethoxylation and assay. Record its entire purchased solution or paste once and carry water/salts as subledgers. Sodium dodecyl sulfate without ethoxy groups is a different substance.

  • Selected flow: Sodium laureth sulfate formulation ingredient
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Actual attributable converted raw-period amount divided once by positive newly accepted supplied net kg, as specified in section 8.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_material
  • Sources: cn113491268-blending
Maleic acid ingredient (maleic_acid)

Measure supplied maleic acid and its actual physical form, assay and moisture; do not substitute maleic anhydride and silently consume water.

  • Selected flow: Maleic acid
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Actual attributable converted raw-period amount divided once by positive newly accepted supplied net kg, as specified in section 8.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_material
  • Sources: cn113491268-blending
Benzotriazole inhibitor (benzotriazole)

Record the actual separately purchased benzotriazole reagent, grade, assay and supplied form. The actual delivery point, carrier, formulation and supplier quantity basis require independent evidence before a native binding is used.

  • Selected flow: Benzotriazole reagent
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Actual attributable converted raw-period amount divided once by positive newly accepted supplied net kg, as specified in section 8.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_material
  • Sources: cn113491268-blending
Separately added water (water)

Use this binding only for supplied water made by ion exchange or reverse osmosis. Native name specifies production mix at plant and pure substance; comment also mentions distillation and consumption supply, but does not waive the narrower name or establish a water-quality standard. CAS 7732-18-5; geography unspecified. Supplier grade, actual treatment and transfer point must be evidenced. The patent does not establish water grade. Do not count water already inside purchased reagents here.

  • Selected flow: Deionised water 5b3acbab-2518-4406-8736-d21f222d757a
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Actual attributable converted raw-period amount divided once by positive newly accepted supplied net kg, as specified in section 8.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_material
  • Sources: cn113491268-blending
Purchased electricity (electricity)

Meter mixing, pumping, ventilation, cleaning, laboratory and attributable holding services. Retain actual voltage, source and geography. Shared equipment uses an independently justified service allocation, not nameplate power as a meter reading. No grid geography or voltage is assigned here.

  • Selected flow: Purchased alternating-current electricity
  • Flow property / unit: Energy / kWh
  • Amount rule: Actual attributable converted raw-period amount divided once by positive newly accepted supplied net kg, as specified in section 8.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_utilities
  • Sources:

Outputs

Product flows
Accepted bulk supplied liquid (finished_liquid)

This is the unique terminal reference Product output; count accepted net liquid once. Generic native inert-surface identity, production mix at plant, no specified CAS, formula, concentration or geography. Do not import its unsupported universal efficacy statement or infer an upstream provider.

  • Selected flow: Disinfectant 93328a0a-7cd1-4f63-831b-e9ac5398506e
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: 1 kg
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_release
  • Sources: cn113491268-blending
Waste flows
Spent aqueous cleaning liquid (spent_wash)

Record actual cleaning liquid sent across the boundary to identified treatment, with peroxide, organic constituents, water and recipient. This is a technosphere waste, not an elementary water discharge. No untreated release is implied.

  • Selected flow: Peroxide-containing aqueous cleaning waste
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Actual attributable converted raw-period amount divided once by positive newly accepted supplied net kg, as specified in section 8.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_losses
  • Sources:
Discarded off-specification blend (offspec_waste)

Only permanently discarded material leaves as waste. Internal return and rework remain internal and retain original burdens until acceptance or disposal; never count them as fresh procurement or positive product.

  • Selected flow: Off-specification peroxide propylene glycol blend waste
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Actual attributable converted raw-period amount divided once by positive newly accepted supplied net kg, as specified in section 8.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_losses
  • Sources:
Elementary flows
Oxygen released to air (oxygen_air)

Record only independently established oxygen release from this operation. Peroxide disappearance alone cannot distinguish decomposition from oxidation of organic ingredients. Air entrainment is not newly formed oxygen.

  • Selected flow: Oxygen, air
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Actual attributable converted raw-period amount divided once by positive newly accepted supplied net kg, as specified in section 8.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_losses
  • Sources:
Water vapour to air (water_air)

Record actual evaporated water separately from liquid waste and peroxide mist. Carrier water, measured final water and independently supported reaction water remain distinct ledgers.

  • Selected flow: Water vapour, air
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Actual attributable converted raw-period amount divided once by positive newly accepted supplied net kg, as specified in section 8.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_losses
  • Sources:
Hydrogen peroxide to air (peroxide_air)

Measure actual gas or aerosol peroxide crossing to air, retaining speciation, phase, capture efficiency and monitoring limits. No universal evaporation or exposure factor.

  • Selected flow: Hydrogen peroxide, air
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Actual attributable converted raw-period amount divided once by positive newly accepted supplied net kg, as specified in section 8.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_losses
  • Sources:
Propylene glycol to air (glycol_air)

Record actual propylene glycol release, including separately measured aerosol. Non-detects retain limits and coverage and do not establish universal zero. Other detected species require separate atomic rows and independent identities.

  • Selected flow: Propylene glycol, air
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Actual attributable converted raw-period amount divided once by positive newly accepted supplied net kg, as specified in section 8.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 kg reference flow
  • Basis kind: process_output
  • Evidence kind: collected_record
  • Collection protocol: cp_losses
  • Sources:

7. Allocation and Co-product Handling

rule_idapplies_torulesource_ids
allocation_directblendAttribute directly to the actual formulation campaign first. Allocate shared utilities, cleaning, laboratory and storage by measured causal service drivers with reconciliation; no mass-only split across different recipes without justification. No saleable co-product is presumed; actual recoveries and co-products require independent output identity and allocation evidence.
allocation_returnsall inventory rowsRetain failed/zero-output burdens, returns and rework; transfer WIP material and its embodied burdens together across period boundaries. An internal rework stream carries its original burden and is not a new purchase or a second accepted product.

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_materialblendIngredient charges and waterbatch_material_recordsowner: production material custodian; period; batch; SKU; supplier; route; location; lot; grade; chemical/isomer identity; supplied form; gross and tare; net mass; assay basis; uncertainty; component water and salts; independent density and temperature if volume measured; opening and closing stocks; return and rework IDsReconcile calibrated scales, goods receipt, actual charge tickets and supplier certificates; qualify a matrix-selective assay with laboratory owner; independently verify each solution procurement basis. Keep receipts, uncharged feed stores, actual production charges and unchanged returns as reconciled separate views of procurement, not additive purchases. Whole supplied liquids and constituent subledgers remain distinct. Retain the compatible attributable raw numerator without division, with complete-period and stock/WIP burden links. After verified raw-unit conversion and attribution, period_normalization alone divides by positive Q. Card amount formulas and aggregation_rule describe that same final reporting operation, not another division. Q=0 retains the complete raw and burden pool without a normalized result.kg; mass fraction; L and kg/L only with measured conditionsEach delivery and chargeFull actual reporting period and linked opening/closing lotsSame site line product route and supplied stateper 1 kg reference flowScale calibration; original charge tickets; certificates; full composition and assay validation
cp_utilitiesblendElectricity and shared servicesmeter_and_service_recordsowner: utilities engineer; meter IDs; readings; interval; batch equipment; voltage; geography; ventilation and laboratory service records; zero-output runs; allocation drivers; opening and closing WIP burdenUse calibrated submeter differences or a reconciled engineering allocation supported by actual service records, including start-up, failed batches, cleaning and holding. Preserve every attributable raw energy interval, including failed/zero-output, cleaning, holding and carried service shares. Retain the compatible attributable raw numerator without division, with complete-period and stock/WIP burden links. After verified raw-unit conversion and attribution, period_normalization alone divides by positive Q. Card amount formulas and aggregation_rule describe that same final reporting operation, not another division. Q=0 retains the complete raw and burden pool without a normalized result.kWhEach interval and batch campaignSame complete actual period with carried-burden linksSame site line product route and supplied stateper 1 kg reference flowMeter calibration and shared-service allocation reconciliation
cp_releaseblendAccepted supplied liquid and WIPmass_and_release_recordsowner: independent quality release officer; complete period; formulation revision; actual assays; selective assay recovery and interference; qualified label/state; batch net mass; release decision; temperature; unique lot IDs; opening/closing WIP mass and carried inventory burdens; internal transfers; failed lots; rework; returns; newly accepted supplied massWeigh net liquid excluding tank/container mass, reconcile tank withdrawals with batch release; independently assay supplied formulation and maintain traceable WIP genealogy. Product-specific low-temperature/efficacy qualification is separate from LCI mass acceptance. Define Q as net newly completed product counted once at its declared final production-acceptance gate, with unique lot/event history. Dispatch or withdrawal of old finished stock, reshipment, internal rework and reinspection/reacceptance of an already counted lot do not create another Q. Reconcile released finished-stock and actual handover records in a separate warehouse ledger; retain the attributable holding/transfer burdens for the matching accepted cohort. Closing unreleased stock/WIP and its carried burdens remain separate from accepted output. Retain the compatible attributable raw numerator without division, with complete-period and stock/WIP burden links. After verified raw-unit conversion and attribution, period_normalization alone divides by positive Q. Card amount formulas and aggregation_rule describe that same final reporting operation, not another division. Q=0 retains the complete raw and burden pool without a normalized result.kgEach batch release and period cut-offFull actual matched period, with earlier and later lot genealogySame site line product route and supplied stateper 1 kg reference flowRelease certificates; scale/tank calibration; genealogy; independent label tests and selective assays
cp_lossesblendWaste and individual emissionsweighing_speciation_and_monitoringowner: environmental metrology officer; full period; waste net mass; composition; treatment recipient; retained samples; rejected mass; gas or liquid integrated volume; conditions; flow rate and duration only for rate records; measured species concentration; detection limit; captured and released fractions; water and elemental inventories; opening/closing retentionReconcile disposal weighing, calibrated monitoring and independent species measurements; investigate missing mass. Validate reaction identity before assigning reaction water or oxygen; never fit unknown outlets with closure residuals. Preserve complete unnormalized waste and separately measured species totals and their stock/cohort attribution. Already integrated volumes receive no extra time multiplier. Retain the compatible attributable raw numerator without division, with complete-period and stock/WIP burden links. After verified raw-unit conversion and attribution, period_normalization alone divides by positive Q. Card amount formulas and aggregation_rule describe that same final reporting operation, not another division. Q=0 retains the complete raw and burden pool without a normalized result.kg; m3 with declared conditions; kg/m3; h only for rate integrationEach waste shipment and emission intervalAll normal, failed, zero-output, cleaning and holding operations in matched periodSame site line product route and supplied stateper 1 kg reference flowManifests; treatment interface; laboratory selectivity/recovery; monitors; physical and elemental closure investigation

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
period_normalizationall inventory rowsFor each exchange, convert the complete raw-period numerator to its declared unit, then divide the compatible attributable quantity once by positive Q as defined by unique first production acceptance in cp_release. Attribute opening carried burdens plus current burdens minus only documented burdens carried in closing unreleased material/WIP or transferred out of that cohort; retain failed/zero-output runs and all rework/return burdens without counting internal transfers twice. Released finished goods and subsequent warehouse/dispatch are separately reconciled and do not create another Q or closing production-WIP subtraction; retain their matched actual holding/transfer burdens. Do not renormalize a previously normalized factor. Q=0 retains raw quantities and the complete burden pool without a normalized result.cp_material; cp_utilities; cp_release; cp_lossesExchange amount per 1 kg reference flow
solution_subledgerperoxide_solution; phosphoric_solution; sles; propylene_glycol; benzotriazoleActive constituent mass = complete supplied reagent mass times independently assayed mass fraction. Water and other constituents use their own measured fractions. Fractions must be on compatible bases; v/v is not w/w. These are subledgers within the one procurement row, not additional inputs.cp_material; cp_releaseNon-additive constituent mass ledgersolvay-peroxide-assay-2019
raw_conversionall inventory rowsUse calibrated mass directly or volume times independently evidenced density at matched concentration and temperature. Rate times duration integrates a rate; an already integrated gas or liquid volume is multiplied by species concentration or independently verified density only, never duration again. No native secondary factor is a density measurement.cp_material; cp_losses; cp_utilitiesConverted raw quantity before normalization
physical_balanceall inventory rowsClose physical mass and elemental inventories separately from assays. For the production pool, actual complete charges plus opening unreleased material/WIP equal unique first-accepted output plus closing unreleased material/WIP, actual waste/releases and documented net transfers. Reconcile uncharged feed stores through a separate receipt/issue ledger; do not add receipts and production charges as two external inputs. Already accepted output is not closing production stock again. Keep released finished goods and subsequent bulk handovers in a separate warehouse ledger, retaining their matched material and embodied burdens. Internal recirculation cancels. Count whole liquids once, water in every carrier separately, and investigated uncertainty. Do not use COD, a single closure residual or peroxide disappearance to solve unknown reaction water and another unknown outlet. Any reaction/species and its water formation or consumption require independent evidence; mixing itself establishes no synthesis yield or reaction water.cp_material; cp_release; cp_lossesIndependent mass elemental water and species balancescn113491268-blending

Data Quality Requirements

requirement_idApplies toRequirementEvidence
quality_identityall inventory rowsRetain complete reagent identity, solution basis, route, grade, geography and provider compatibility. Blank auxiliary UUIDs require later verified binding, not surrogate chemicals.Supplier certificates and native identity evidence
quality_assayreference productLaboratory owner must demonstrate matrix-specific selectivity, recovery and interference control for active peroxide and independently characterize water and other ingredients. The cited incoming-peroxide permanganate method does not establish selectivity in an organic blend; reject COD/residual-based speciation. Missing actual assay/qualification prevents use of that concrete dataset.Validated laboratory procedure; recovery and blank/interference study; independent product qualification
quality_periodall inventory rowsReconcile complete raw periods and unique accepted supplied output, including zero-output failures, rework, stock and WIP movements and carried burdens; retain original records, uncertainty and exclusions.Full-period ledger and batch genealogy

9. Validation Rules

rule_idapplies_torulesource_ids
validate_referencefinished_liquidRequire one terminal Product output linked by finished_liquid, the declared UUID, Mass/kg and net whole-liquid acceptance. Both languages must select the same physical output.
validate_ledgersall inventory rowsCheck complete solution procurement, separate constituent subledgers, physical and elemental closure, independent species/water evidence, full-period attribution and one normalization. Unexplained closure or unsupported species is an unresolved finding, not a fitted loss or zero.
validate_claimsreference productRequire actual product-specific assays and label/state qualification before using a concrete dataset. Neither the patent nor the generic native efficacy sentence establishes approved concentration, minimum-use temperature, killing effect, dose, exposure or emissions.nhc-low-temperature-2020; solvay-peroxide-assay-2019

10. Published Dataset Profile

FieldValue
dataset_rolesecondary_dataset; background_dataset
downstream_useInput to an explicitly scoped surface-disinfection model
allowed_useSame supplied formulation state and verified upstream basis, with measured foreground inventory
excluded_useGeneric per-kg active ingredient, universal disinfectant, agricultural fungicide, handrub, efficacy equivalence or use-stage emission default
required_metadataFormulation revision; complete solution procurement basis; assays; ingredient grades/routes; location; period; bulk supply interface; WIP genealogy; provider compatibility
required_quality_disclosureActual assay validation and label limits; inventory completeness; uncertainty; unbound auxiliary identities; native generic identity limitations; missing measurements
update_triggerChanged formulation, assay method, supplier basis, grade, route, product state, label, site operation or period

11. Data Sources

Source idTypeReferenceUsed for
un-cpc3-2025official_guidanceUN Statistics Division, CPC 3.0 Explanatory Notes, 30 June 2025, p.167. https://unstats.un.org/unsd/classifications/Econ/Download/In%20Text/CPC_Ver_3.0_Exp_Notes_30Jun2025.pdfSibling category boundary only; no recipe, effectiveness or accepted mapping.
wco-disinfectants-2022official_guidanceWCO, HS classification reference for Covid-19 medical supplies, edition 3.01, 15 January 2022, p.5. https://www.wcoomd.org/-/media/wco/public/global/pdf/topics/nomenclature/covid_19/hs-classification-reference_edition-3_en.pdf?la=enPrepared surface disinfectants versus bulk chemical feedstocks; HS2022 guidance, not a customs ruling or product approval.
cn113491268-blendingliteratureCN113491268A, 一种低温过氧化氢消毒液及其制备方法, 12 October 2021, paragraphs 0038–0062, PDF pp.5–6. https://patents.google.com/patent/CN113491268A/zhPrimary patent examples support the selected ingredient set and sequential mixing only. Charge labels do not resolve supplied reagent assay, water grade or surfactant ethoxylation. Ratios, speed, duration, scale-up energy, temperature claims, shelf life, efficacy and environmental-safety claims are not defaults or approval.
nhc-low-temperature-2020official_guidance国家卫生健康委, 低温消毒剂卫生安全评价技术要求, attachment to 国卫办监督函〔2020〕1062号, pp.1–2. https://www.nhc.gov.cn/zhjcj/c100093/202012/b9c35590fd93459cadc5ae295a2e9279/files/1732842589101_90541.pdfHistorical Chinese guidance supports separate label-temperature qualification. It supplies no production recipe, LCI factor or universal kill rate. Current market compliance and actual product tests require separate verification.
solvay-peroxide-assay-2019method_factorSolvay, Determination of Hydrogen Peroxide Concentration (20% to 70%), 08/19, FN 1167/01, p.1 Scope/Principle. https://www.solvay.com/sites/g/files/srpend616/files/2019-10/H2O2%20Determination%20of%20Hydrogen%20Peroxide%20Concentration%20-20%20to%2070-.pdfIncoming aqueous-peroxide assay guidance is limited to its stated concentration and interference scope. Acid-permanganate oxidizable compounds interfere; do not apply it unvalidated to this organic formulated matrix or infer peroxide loss from COD.

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 3
Rule IDApplies toRuleSource IDs
boundary_routeblendInclude receiving, storage, sequential dilution/mixing, analytical release, holding, cleaning and transfer with all associated real burdens; physical mixing is not chemical synthesis.cn113491268-blending
boundary_scopereference productExclude agricultural crop/seed protection and upstream bulk chemicals from this foreground scope; retain their applicable upstream burdens rather than silently omitting them.un-cpc3-2025, wco-disinfectants-2022
boundary_usereference productDownstream application, exposure and environmental fate are outside this production inventory. Any such model needs separate actual-use evidence and separately qualified emissions.nhc-low-temperature-2020
Allocation rules · 2
Rule IDApplies toRuleSource IDs
allocation_directblendAttribute directly to the actual formulation campaign first. Allocate shared utilities, cleaning, laboratory and storage by measured causal service drivers with reconciliation; no mass-only split across different recipes without justification. No saleable co-product is presumed; actual recoveries and co-products require independent output identity and allocation evidence.
allocation_returnsall inventory rowsRetain failed/zero-output burdens, returns and rework; transfer WIP material and its embodied burdens together across period boundaries. An internal rework stream carries its original burden and is not a new purchase or a second accepted product.
Validation rules · 3
Rule IDApplies toRuleSource IDs
validate_referencefinished_liquidRequire one terminal Product output linked by finished_liquid, the declared UUID, Mass/kg and net whole-liquid acceptance. Both languages must select the same physical output.
validate_ledgersall inventory rowsCheck complete solution procurement, separate constituent subledgers, physical and elemental closure, independent species/water evidence, full-period attribution and one normalization. Unexplained closure or unsupported species is an unresolved finding, not a fitted loss or zero.
validate_claimsreference productRequire actual product-specific assays and label/state qualification before using a concrete dataset. Neither the patent nor the generic native efficacy sentence establishes approved concentration, minimum-use temperature, killing effect, dose, exposure or emissions.nhc-low-temperature-2020, solvay-peroxide-assay-2019
Processes and inputs/outputs · 1
Process IDProcess nameInput flowsOutput flows
blendPurchased-reagent blending and bulk supply87

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page