TianGong PCR

Natural water

Lifecycle status
Candidate
Content maturity
Authored methodology
Current version
No published versionLast updated
Readiness
Review required

Methodology and translation states come from the source record; publishing this website does not change their review status.

Content languages

zh-CN · Aligned
Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:18000 · exact

Source

1. Scope and Applicability

This PCR covers potable or non-potable bulk water suitable for a declared further use, including untreated freshwater abstraction, conventional treatment, membrane or thermal desalination and reclamation of used water. Fix the actual source, treatment train and quality. The supply gate may be the plant meter or a declared network handover; include network pumping, flushing and leakage only for that boundary. Raw seawater as a marketed product, steam/hot water, bottled beverages, carbonated mineral water, distilled-water chemical products and water unsuitable for further use are excluded. Wastewater-treatment service and usable reclaimed-water supply require separate burden and product declarations. For ion exchange, adsorption or additional reclamation steps, add the actual resin, regenerant, activated carbon, residual and pollutant exchanges individually; the candidate cards do not replace a plant audit. epa-water-2004, doe-desalination, doe-alternative-water

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.ores-and-minerals-electricity-gas-and-water.natural-water.natural-water
classification_refsCPC 3.0:18000
covered_productsBulk liquid water meeting one declared further-use specification
excluded_productsMarketed seawater; hot-water heat supply; distilled-water chemicals; bottled/carbonated beverages; unusable wastewater
representative_productBulk water suitable for the declared further use
production_routeWater intake and pumping; Clarification, filtration and disinfection; Membrane desalination; Thermal desalination; Used-water reclamation; Supply metering and declared distribution
market_stateOne metered plant or distribution gate at measured water temperature

3. Reference Flow

FieldValue
WhatSupply fit-for-declared-use bulk water, without claiming universal potable/non-potable equivalence
How much1 m3
How wellsite, basin and year; source and salinity; untreated/treated/reclaimed state; intended further use and quality evidence; treatment train; meter temperature; plant/network gate; losses and stock change; residual fate; allocation; energy supply
How long or cycleOne gate supply within a declared production period
reference_flow_linkfinal_product
FieldValue
Reference amount1
Reference product flowBulk water suitable for the declared further use
Reference flow propertyVolume 93a60a56-a3c8-22da-a746-0800200c9a66
Reference unit groupUnits of volume 93a60a57-a3c8-12da-a746-0800200c9a66
Reference unitm3
Required qualifierssite, basin and year; source and salinity; untreated/treated/reclaimed state; intended further use and quality evidence; treatment train; meter temperature; plant/network gate; losses and stock change; residual fate; allocation; energy supply

Declare all qualifiers in dataset metadata or reference-flow comments. The representative identity is usable only for its confirmed product state, geography and property; resolve a distinct flow for incompatible variants. It does not impose a default product composition.

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
reference_basisfinal_productVolumem3D is the positive accepted net gate-output total in m3. Exclude packaging and cancelled internal transfers. cp_output records D; every card uses per 1 m3 reference flow.
conversionutility and material rowsDeclared row propertykg; m3; MJRetain raw readings. Electricity: 1 kWh = 3.6 MJ. Mass/volume conversion requires measured density, temperature and applicable pressure; retain water content and active chemical fraction.
category_balanceproductionVolumem3Close source-water, product, concentrate, sludge water, backwash, reuse, evaporation, flushing, network losses and stock balances. D is accepted net m3 at the declared gate; record meter temperature. Convert chemical solution and wet sludge masses with measured concentration and moisture. Abstraction is not equal to consumption: disclose receiving basin and returned quantity/quality. Do not convert m3 to kg using an undocumented universal density.

5. System Boundary

Boundary Abstraction

FieldValue
declared_starting_conditionIdentified natural freshwater or seawater resource, supplied raw water, or traceable used-water feed for reclamation
starting_condition_roleResource or supplied feed; declare which
product_classification_scopeBulk liquid water meeting one declared further-use specification
recursive_input_rulePurchased same-category material carries a distinct supplier dataset; internal recycling is a balance observation, not a new external input or credit.
upstream_dataset_requirementLink feed, electricity, fuels, chemicals, infrastructure and waste-management burdens; disclose any missing coverage.
disclosuresite, basin and year; source and salinity; untreated/treated/reclaimed state; intended further use and quality evidence; treatment train; meter temperature; plant/network gate; losses and stock change; residual fate; allocation; energy supply
rule_idApplies toRulesource_ids
boundary_operationssiteThis PCR covers potable or non-potable bulk water suitable for a declared further use, including untreated freshwater abstraction, conventional treatment, membrane or thermal desalination and reclamation of used water. Fix the actual source, treatment train and quality. The supply gate may be the plant meter or a declared network handover; include network pumping, flushing and leakage only for that boundary. Raw seawater as a marketed product, steam/hot water, bottled beverages, carbonated mineral water, distilled-water chemical products and water unsuitable for further use are excluded. Wastewater-treatment service and usable reclaimed-water supply require separate burden and product declarations. For ion exchange, adsorption or additional reclamation steps, add the actual resin, regenerant, activated carbon, residual and pollutant exchanges individually; the candidate cards do not replace a plant audit.epa-water-2004, doe-desalination, doe-alternative-water
boundary_partitionall exchangesInclude actual conditioning, storage, handling and pollution controls through the declared gate. Account for attributable construction and closure with a disclosed lifetime-output basis or justified exclusion and sensitivity. Separate purchased fuel supply from foreground combustion and purchased treatment from site releases.
boundary_completenessinventoryCards define individual likely exchanges and route conditions, not an exhaustive site audit. Add each actual absent chemical, waste, resource, land transformation and pollutant as its own row. Absence, measured zero and unknown must be distinguished.

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
intakeWater intake and pumpingconditionalResource or purchased-feed intakeForeground productionper 1 m3 reference flow
conventionalClarification, filtration and disinfectionconditionalConventional treatment or reclaimed-water polishingForeground productionper 1 m3 reference flow
membraneMembrane desalinationconditionalActual membrane routeForeground productionper 1 m3 reference flow
thermalThermal desalinationconditionalActual thermal routeForeground productionper 1 m3 reference flow
reuseUsed-water reclamationconditionalReclaimed-water routeForeground productionper 1 m3 reference flow
supplySupply metering and declared distributionrequiredAll declared sitesForeground productionper 1 m3 reference flow

Process: Water intake and pumping (intake)

Inputs

Product flows
Supplied raw water (purchased_raw_water)

Only purchased water; provider carries abstraction burden, so do not also count a resource withdrawal.

  • Selected flow: Supplied raw water
  • Flow property / unit: Volume / m3
  • Amount rule: Collect the attributable reporting-period quantity under cp_purchased_raw_water; divide by D after stock, transfer and allocation reconciliation.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 m3 reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_purchased_raw_water
  • Sources: epa-water-2004, doe-desalination, doe-alternative-water
Intake electricity (intake_power)

This purchased electricity exchange requires independently confirmed actual supplier, consumption or production interface, geography, voltage, generation attributes and energy property/unit; its UUID remains unresolved until a compatible direct-read identity is confirmed. A waste-incineration generation flow must not represent arbitrary site power.

Actual intake pumping and screens.

  • Selected flow: Electricity
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Collect the attributable reporting-period quantity under cp_intake_power; divide by D after stock, transfer and allocation reconciliation.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 m3 reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_intake_power
  • Sources: epa-water-2004, doe-desalination, doe-alternative-water
Elementary flows
River-water withdrawal (river_resource)

Only direct river abstraction; identify basin and intake meter.

  • Selected flow: river water 805a7346-1664-4483-afe3-4b224be5e361
  • Flow property / unit: Volume / m3
  • Amount rule: Collect the attributable reporting-period quantity under cp_river_resource; divide by D after stock, transfer and allocation reconciliation.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 m3 reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_river_resource
  • Sources: epa-water-2004, doe-desalination, doe-alternative-water
Groundwater withdrawal (groundwater_resource)

Only direct groundwater abstraction; record aquifer and pumping.

  • Selected flow: ground water 4f462198-40cd-4184-8733-86648a20dc3f
  • Flow property / unit: Volume / m3
  • Amount rule: Collect the attributable reporting-period quantity under cp_groundwater_resource; divide by D after stock, transfer and allocation reconciliation.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 m3 reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_groundwater_resource
  • Sources: epa-water-2004, doe-desalination, doe-alternative-water
Seawater abstraction for desalination (seawater_resource)

Only actual seawater intake; distinguish from marketed raw seawater.

  • Selected flow: Seawater abstraction for desalination
  • Flow property / unit: Volume / m3
  • Amount rule: Collect the attributable reporting-period quantity under cp_seawater_resource; divide by D after stock, transfer and allocation reconciliation.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 m3 reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_seawater_resource
  • Sources: epa-water-2004, doe-desalination, doe-alternative-water

Process: Clarification, filtration and disinfection (conventional)

Inputs

Product flows
Aluminium-sulfate coagulant (aluminium_sulfate)

Only an actual alum coagulation route; record active fraction and solution mass separately.

  • Selected flow: Aluminium-sulfate coagulant
  • Flow property / unit: Mass / kg
  • Amount rule: Collect the attributable reporting-period quantity under cp_aluminium_sulfate; divide by D after stock, transfer and allocation reconciliation.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 m3 reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_aluminium_sulfate
  • Sources: epa-water-2004, doe-desalination, doe-alternative-water
Sodium-hypochlorite disinfectant (sodium_hypochlorite)

Only the actual hypochlorite route; other disinfectants and UV electricity require separate cards.

  • Selected flow: Sodium-hypochlorite disinfectant
  • Flow property / unit: Mass / kg
  • Amount rule: Collect the attributable reporting-period quantity under cp_sodium_hypochlorite; divide by D after stock, transfer and allocation reconciliation.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 m3 reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_sodium_hypochlorite
  • Sources: epa-water-2004, doe-desalination, doe-alternative-water
Treatment electricity (treatment_power)

This purchased electricity exchange requires independently confirmed actual supplier, consumption or production interface, geography, voltage, generation attributes and energy property/unit; its UUID remains unresolved until a compatible direct-read identity is confirmed. A waste-incineration generation flow must not represent arbitrary site power.

Mixing, filtration, backwash and actual disinfection equipment.

  • Selected flow: Electricity
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Collect the attributable reporting-period quantity under cp_treatment_power; divide by D after stock, transfer and allocation reconciliation.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 m3 reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_treatment_power
  • Sources: epa-water-2004, doe-desalination, doe-alternative-water

Outputs

Waste flows
Water-treatment sludge (treatment_sludge)

Transferred wet sludge with dry-solids fraction, contaminants and treatment fate.

  • Selected flow: Water-treatment sludge
  • Flow property / unit: Mass / kg
  • Amount rule: Collect the attributable reporting-period quantity under cp_treatment_sludge; divide by D after stock, transfer and allocation reconciliation.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 m3 reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_treatment_sludge
  • Sources: epa-water-2004, doe-desalination, doe-alternative-water

Process: Membrane desalination (membrane)

Inputs

Product flows
Membrane-system electricity (membrane_power)

This purchased electricity exchange requires independently confirmed actual supplier, consumption or production interface, geography, voltage, generation attributes and energy property/unit; its UUID remains unresolved until a compatible direct-read identity is confirmed. A waste-incineration generation flow must not represent arbitrary site power.

Actual high-pressure, circulation and recovery auxiliaries; net recovered energy is reconciled, not credited twice.

  • Selected flow: Electricity
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Collect the attributable reporting-period quantity under cp_membrane_power; divide by D after stock, transfer and allocation reconciliation.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 m3 reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_membrane_power
  • Sources: epa-water-2004, doe-desalination, doe-alternative-water
Replacement polyamide RO membrane (polyamide_membrane)

Only actual polyamide RO modules; record service replacement fraction and disposal once.

  • Selected flow: Replacement polyamide RO membrane
  • Flow property / unit: Mass / kg
  • Amount rule: Collect the attributable reporting-period quantity under cp_polyamide_membrane; divide by D after stock, transfer and allocation reconciliation.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 m3 reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_polyamide_membrane
  • Sources: epa-water-2004, doe-desalination, doe-alternative-water

Outputs

Waste flows
RO concentrate transferred for management (membrane_concentrate)

Only treatment/management transfers; direct receiving-water releases need species and compartment rows.

  • Selected flow: RO concentrate transferred for management
  • Flow property / unit: Volume / m3
  • Amount rule: Collect the attributable reporting-period quantity under cp_membrane_concentrate; divide by D after stock, transfer and allocation reconciliation.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 m3 reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_membrane_concentrate
  • Sources: epa-water-2004, doe-desalination, doe-alternative-water

Process: Thermal desalination (thermal)

Inputs

Product flows
Imported desalination heat (desalination_heat)

Actual imported thermal energy; on-site heat generation uses its own fuel/combustion inventory.

  • Selected flow: Imported desalination heat
  • Flow property / unit: Energy / MJ
  • Amount rule: Collect the attributable reporting-period quantity under cp_desalination_heat; divide by D after stock, transfer and allocation reconciliation.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 m3 reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_desalination_heat
  • Sources: epa-water-2004, doe-desalination, doe-alternative-water
Thermal-desalination electricity (thermal_power)

This purchased electricity exchange requires independently confirmed actual supplier, consumption or production interface, geography, voltage, generation attributes and energy property/unit; its UUID remains unresolved until a compatible direct-read identity is confirmed. A waste-incineration generation flow must not represent arbitrary site power.

Actual evaporation, circulation and distillate pumps.

  • Selected flow: Electricity
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Collect the attributable reporting-period quantity under cp_thermal_power; divide by D after stock, transfer and allocation reconciliation.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 m3 reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_thermal_power
  • Sources: epa-water-2004, doe-desalination, doe-alternative-water

Outputs

Waste flows
Thermal-desalination brine transferred for management (thermal_brine)

Record temperature, salinity and management fate; species-resolved direct discharge separately.

  • Selected flow: Thermal-desalination brine transferred for management
  • Flow property / unit: Volume / m3
  • Amount rule: Collect the attributable reporting-period quantity under cp_thermal_brine; divide by D after stock, transfer and allocation reconciliation.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 m3 reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_thermal_brine
  • Sources: epa-water-2004, doe-desalination, doe-alternative-water

Process: Used-water reclamation (reuse)

Inputs

Product flows
Reclamation electricity (reuse_power)

This purchased electricity exchange requires independently confirmed actual supplier, consumption or production interface, geography, voltage, generation attributes and energy property/unit; its UUID remains unresolved until a compatible direct-read identity is confirmed. A waste-incineration generation flow must not represent arbitrary site power.

Actual reclamation process; disaggregate aeration, pumping and polishing and avoid duplicate conventional-stage meters.

  • Selected flow: Electricity
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Collect the attributable reporting-period quantity under cp_reuse_power; divide by D after stock, transfer and allocation reconciliation.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 m3 reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_reuse_power
  • Sources: epa-water-2004, doe-desalination, doe-alternative-water
Waste flows
Used-water feed unsuitable before reclamation (used_water_feed)

Only actual waste-water feed; already suitable supplied reclaimed water is a product input with a provider.

  • Selected flow: Used-water feed unsuitable before reclamation
  • Flow property / unit: Volume / m3
  • Amount rule: Collect the attributable reporting-period quantity under cp_used_water_feed; divide by D after stock, transfer and allocation reconciliation.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 m3 reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_used_water_feed
  • Sources: epa-water-2004, doe-desalination, doe-alternative-water

Outputs

Waste flows
Sludge from used-water reclamation (reclamation_sludge)

Only actual reclaimed-water processing solids; distinguish upstream wastewater-treatment sludge and assign each treatment burden once.

  • Selected flow: Sludge from used-water reclamation
  • Flow property / unit: Mass / kg
  • Amount rule: Collect the attributable reporting-period quantity under cp_reclamation_sludge; divide by D after stock, transfer and allocation reconciliation.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 m3 reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_reclamation_sludge
  • Sources: epa-water-2004, doe-desalination, doe-alternative-water

Process: Supply metering and declared distribution (supply)

Inputs

Product flows
Supply electricity (supply_power)

This purchased electricity exchange requires independently confirmed actual supplier, consumption or production interface, geography, voltage, generation attributes and energy property/unit; its UUID remains unresolved until a compatible direct-read identity is confirmed. A waste-incineration generation flow must not represent arbitrary site power.

Include distribution pumping only when the selected reference gate extends through the network.

  • Selected flow: Electricity
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Collect the attributable reporting-period quantity under cp_supply_power; divide by D after stock, transfer and allocation reconciliation.
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 m3 reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_supply_power
  • Sources: epa-water-2004, doe-desalination, doe-alternative-water

Outputs

Product flows
Bulk water suitable for the declared further use (final_product)

One quality specification and gate; exclude unusable residuals and separately declared seawater products.

  • Selected flow: Bulk water suitable for the declared further use
  • Flow property / unit: Volume / m3
  • Amount rule: 1 m3
  • Value mode: foreground_record
  • Specificity: site_specific
  • Normalization basis: per 1 m3 reference flow
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_output
  • Sources: epa-water-2004, doe-desalination, doe-alternative-water

7. Allocation and Co-product Handling

rule_idApplies toRulesource_ids
allocation_hierarchyjoint productionPrefer process subdivision or defensible system expansion; otherwise use demonstrated physical causality. Use economic allocation only with consistent period, price, currency and sensitivity when physical causality is unavailable. Retain the unallocated inventory.ef-allocation-2021
allocation_productreference and co-productsSeparate raw-water abstraction, treatment, desalination, reuse and distribution meters. For co-produced heat, power or salt, retain unallocated inventories and demonstrated physical relationships. Reclaimed water is not automatically burden-free and avoided freshwater is not an automatic credit; declare the wastewater-treatment service and recycling allocation consistently.
allocation_wastewaste and recyclingClassify each output by physical state and actual fate. A sale does not automatically make a residue a co-product; internal recycling receives no avoided-product credit. Apply treatment burdens once.

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_river_resourceintakeriver_resourcemeasurement_recordperiod; site; amount; original unit; uncertainty; stock changes; route condition; allocation; D; product qualifiersIntegrate the calibrated source/input meter over matched operating intervals; record basin or provider, source salinity and quality, temperature, opening/closing storage, bypass and recycle. Record return-water quantity and destination separately. Do not infer intake from product volume or assume intake equals consumption.m3Each meter interval or shipment; monthly reconciliationComplete year or justified representative production campaignOne metered plant or distribution gate at measured water temperatureper 1 m3 reference flowCalibration; original records; assay; balance residuals; uncertainty
cp_groundwater_resourceintakegroundwater_resourcemeasurement_recordperiod; site; amount; original unit; uncertainty; stock changes; route condition; allocation; D; product qualifiersIntegrate the calibrated source/input meter over matched operating intervals; record basin or provider, source salinity and quality, temperature, opening/closing storage, bypass and recycle. Record return-water quantity and destination separately. Do not infer intake from product volume or assume intake equals consumption.m3Each meter interval or shipment; monthly reconciliationComplete year or justified representative production campaignOne metered plant or distribution gate at measured water temperatureper 1 m3 reference flowCalibration; original records; assay; balance residuals; uncertainty
cp_seawater_resourceintakeseawater_resourcemeasurement_recordperiod; site; amount; original unit; uncertainty; stock changes; route condition; allocation; D; product qualifiersIntegrate the calibrated source/input meter over matched operating intervals; record basin or provider, source salinity and quality, temperature, opening/closing storage, bypass and recycle. Record return-water quantity and destination separately. Do not infer intake from product volume or assume intake equals consumption.m3Each meter interval or shipment; monthly reconciliationComplete year or justified representative production campaignOne metered plant or distribution gate at measured water temperatureper 1 m3 reference flowCalibration; original records; assay; balance residuals; uncertainty
cp_purchased_raw_waterintakepurchased_raw_watermeasurement_recordperiod; site; amount; original unit; uncertainty; stock changes; route condition; allocation; D; product qualifiersIntegrate the calibrated source/input meter over matched operating intervals; record basin or provider, source salinity and quality, temperature, opening/closing storage, bypass and recycle. Record return-water quantity and destination separately. Do not infer intake from product volume or assume intake equals consumption.m3Each meter interval or shipment; monthly reconciliationComplete year or justified representative production campaignOne metered plant or distribution gate at measured water temperatureper 1 m3 reference flowCalibration; original records; assay; balance residuals; uncertainty
cp_intake_powerintakeintake_powermeasurement_recordperiod; site; amount; original unit; uncertainty; stock changes; route condition; allocation; D; product qualifiersCalibrated weighing, metering or traceable transfer records; reconcile period, opening/closing stock, actual grade and boundary.MJEach meter interval or shipment; monthly reconciliationComplete year or justified representative production campaignOne metered plant or distribution gate at measured water temperatureper 1 m3 reference flowCalibration; original records; assay; balance residuals; uncertainty
cp_aluminium_sulfateconventionalaluminium_sulfatemeasurement_recordperiod; site; amount; original unit; uncertainty; stock changes; route condition; allocation; D; product qualifiersReconcile weighed deliveries, tank inventory changes and actual dosing logs; retain solution density and measured active concentration. Normalize active chemical mass and disclose the carrier water without double counting.kgEach meter interval or shipment; monthly reconciliationComplete year or justified representative production campaignOne metered plant or distribution gate at measured water temperatureper 1 m3 reference flowCalibration; original records; assay; balance residuals; uncertainty
cp_sodium_hypochloriteconventionalsodium_hypochloritemeasurement_recordperiod; site; amount; original unit; uncertainty; stock changes; route condition; allocation; D; product qualifiersReconcile weighed deliveries, tank inventory changes and actual dosing logs; retain solution density and measured active concentration. Normalize active chemical mass and disclose the carrier water without double counting.kgEach meter interval or shipment; monthly reconciliationComplete year or justified representative production campaignOne metered plant or distribution gate at measured water temperatureper 1 m3 reference flowCalibration; original records; assay; balance residuals; uncertainty
cp_treatment_powerconventionaltreatment_powermeasurement_recordperiod; site; amount; original unit; uncertainty; stock changes; route condition; allocation; D; product qualifiersCalibrated weighing, metering or traceable transfer records; reconcile period, opening/closing stock, actual grade and boundary.MJEach meter interval or shipment; monthly reconciliationComplete year or justified representative production campaignOne metered plant or distribution gate at measured water temperatureper 1 m3 reference flowCalibration; original records; assay; balance residuals; uncertainty
cp_treatment_sludgeconventionaltreatment_sludgemeasurement_recordperiod; site; amount; original unit; uncertainty; stock changes; route condition; allocation; D; product qualifiersMeasure transferred residue by calibrated volume or weight records matched to salinity, wet/dry-solids assay, temperature and final management fate. Separate returned water and direct receiving-water species; retain transport and treatment provider information.kgEach meter interval or shipment; monthly reconciliationComplete year or justified representative production campaignOne metered plant or distribution gate at measured water temperatureper 1 m3 reference flowCalibration; original records; assay; balance residuals; uncertainty
cp_membrane_powermembranemembrane_powermeasurement_recordperiod; site; amount; original unit; uncertainty; stock changes; route condition; allocation; D; product qualifiersCalibrated weighing, metering or traceable transfer records; reconcile period, opening/closing stock, actual grade and boundary.MJEach meter interval or shipment; monthly reconciliationComplete year or justified representative production campaignOne metered plant or distribution gate at measured water temperatureper 1 m3 reference flowCalibration; original records; assay; balance residuals; uncertainty
cp_polyamide_membranemembranepolyamide_membranemeasurement_recordperiod; site; amount; original unit; uncertainty; stock changes; route condition; allocation; D; product qualifiersCalibrated weighing, metering or traceable transfer records; reconcile period, opening/closing stock, actual grade and boundary.kgEach meter interval or shipment; monthly reconciliationComplete year or justified representative production campaignOne metered plant or distribution gate at measured water temperatureper 1 m3 reference flowCalibration; original records; assay; balance residuals; uncertainty
cp_membrane_concentratemembranemembrane_concentratemeasurement_recordperiod; site; amount; original unit; uncertainty; stock changes; route condition; allocation; D; product qualifiersMeasure transferred residue by calibrated volume or weight records matched to salinity, wet/dry-solids assay, temperature and final management fate. Separate returned water and direct receiving-water species; retain transport and treatment provider information.m3Each meter interval or shipment; monthly reconciliationComplete year or justified representative production campaignOne metered plant or distribution gate at measured water temperatureper 1 m3 reference flowCalibration; original records; assay; balance residuals; uncertainty
cp_desalination_heatthermaldesalination_heatmeasurement_recordperiod; site; amount; original unit; uncertainty; stock changes; route condition; allocation; D; product qualifiersCalibrated weighing, metering or traceable transfer records; reconcile period, opening/closing stock, actual grade and boundary.MJEach meter interval or shipment; monthly reconciliationComplete year or justified representative production campaignOne metered plant or distribution gate at measured water temperatureper 1 m3 reference flowCalibration; original records; assay; balance residuals; uncertainty
cp_thermal_powerthermalthermal_powermeasurement_recordperiod; site; amount; original unit; uncertainty; stock changes; route condition; allocation; D; product qualifiersCalibrated weighing, metering or traceable transfer records; reconcile period, opening/closing stock, actual grade and boundary.MJEach meter interval or shipment; monthly reconciliationComplete year or justified representative production campaignOne metered plant or distribution gate at measured water temperatureper 1 m3 reference flowCalibration; original records; assay; balance residuals; uncertainty
cp_thermal_brinethermalthermal_brinemeasurement_recordperiod; site; amount; original unit; uncertainty; stock changes; route condition; allocation; D; product qualifiersMeasure transferred residue by calibrated volume or weight records matched to salinity, wet/dry-solids assay, temperature and final management fate. Separate returned water and direct receiving-water species; retain transport and treatment provider information.m3Each meter interval or shipment; monthly reconciliationComplete year or justified representative production campaignOne metered plant or distribution gate at measured water temperatureper 1 m3 reference flowCalibration; original records; assay; balance residuals; uncertainty
cp_used_water_feedreuseused_water_feedmeasurement_recordperiod; site; amount; original unit; uncertainty; stock changes; route condition; allocation; D; product qualifiersIntegrate the calibrated source/input meter over matched operating intervals; record basin or provider, source salinity and quality, temperature, opening/closing storage, bypass and recycle. Record return-water quantity and destination separately. Do not infer intake from product volume or assume intake equals consumption.m3Each meter interval or shipment; monthly reconciliationComplete year or justified representative production campaignOne metered plant or distribution gate at measured water temperatureper 1 m3 reference flowCalibration; original records; assay; balance residuals; uncertainty
cp_reuse_powerreusereuse_powermeasurement_recordperiod; site; amount; original unit; uncertainty; stock changes; route condition; allocation; D; product qualifiersCalibrated weighing, metering or traceable transfer records; reconcile period, opening/closing stock, actual grade and boundary.MJEach meter interval or shipment; monthly reconciliationComplete year or justified representative production campaignOne metered plant or distribution gate at measured water temperatureper 1 m3 reference flowCalibration; original records; assay; balance residuals; uncertainty
cp_supply_powersupplysupply_powermeasurement_recordperiod; site; amount; original unit; uncertainty; stock changes; route condition; allocation; D; product qualifiersCalibrated weighing, metering or traceable transfer records; reconcile period, opening/closing stock, actual grade and boundary.MJEach meter interval or shipment; monthly reconciliationComplete year or justified representative production campaignOne metered plant or distribution gate at measured water temperatureper 1 m3 reference flowCalibration; original records; assay; balance residuals; uncertainty
cp_outputsupplyfinal_productmeasurement_recordperiod; site; amount; original unit; uncertainty; stock changes; route condition; allocation; D; product qualifiersRecord calibrated outlet volumetric meter readings and water temperature at the chosen plant/network gate, subtract nonconforming and rejected output, reconcile storage and transfers, and independently retain positive net accepted volume D in m3. Match water-quality sampling to the reporting period and intended-use specification.m3Each meter interval or shipment; monthly reconciliationComplete year or justified representative production campaignOne metered plant or distribution gate at measured water temperatureper 1 m3 reference flowCalibration; original records; assay; balance residuals; uncertainty
cp_reclamation_sludgereusereclamation_sludgemeasurement_recordperiod; site; amount; original unit; uncertainty; stock changes; route condition; allocation; D; product qualifiersCalibrated weighing, metering or traceable transfer records; reconcile period, opening/closing stock, actual grade and boundary.kgEach meter interval or shipment; monthly reconciliationComplete year or justified representative production campaignOne metered plant or distribution gate at measured water temperatureper 1 m3 reference flowCalibration; original records; assay; balance residuals; uncertainty

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
normalizationall cardsExchange = attributable period quantity / D. Reconcile inventories and cancel internal transfers before aggregation.cp_output; row-specific cp recordsper 1 m3 reference flow
physical_balanceproductionClose source-water, product, concentrate, sludge water, backwash, reuse, evaporation, flushing, network losses and stock balances. D is accepted net m3 at the declared gate; record meter temperature. Convert chemical solution and wet sludge masses with measured concentration and moisture. Abstraction is not equal to consumption: disclose receiving basin and returned quantity/quality. Do not convert m3 to kg using an undocumented universal density.Matched mass, volume, composition and stock measurementsBalance residual and uncertainty

Data Quality Requirements

requirement_idApplies toRequirementEvidence
representativenessdatasetUse matching production and exchange periods, actual technology, geography and supplier state. Record startup, shutdown, seasonal variation and substitutions.collection records
identity_and_rangesall cardsUnresolved identities and missing independent range evidence remain explicit. Do not replace measurement by a guessed industry range or by missing-as-zero.manifest review metadata

9. Validation Rules

rule_idApplies toRulesource_ids
validate_referencefinal_productVerify 1 m3, positive D, product state, property/unit and every required qualifier. Each dataset fixes one product and route.
validate_balancesiteClose source-water, product, concentrate, sludge water, backwash, reuse, evaporation, flushing, network losses and stock balances. D is accepted net m3 at the declared gate; record meter temperature. Convert chemical solution and wet sludge masses with measured concentration and moisture. Abstraction is not equal to consumption: disclose receiving basin and returned quantity/quality. Do not convert m3 to kg using an undocumented universal density.
validate_coveragehandoffVerify each applicable exchange, its provider or environmental compartment and final waste fate; identify skipped checks, unresolved identities, missing measurements and upstream gaps. Errors or unassessed mandatory coverage cannot be labelled complete.

10. Published Dataset Profile

FieldValue
dataset_roleforeground_dataset
downstream_usesecondary_dataset; background_dataset
allowed_useSupply fit-for-declared-use bulk water, without claiming universal potable/non-potable equivalence
excluded_useMarketed seawater; hot-water heat supply; distilled-water chemicals; bottled/carbonated beverages; unusable wastewater
required_metadatasite, basin and year; source and salinity; untreated/treated/reclaimed state; intended further use and quality evidence; treatment train; meter temperature; plant/network gate; losses and stock change; residual fate; allocation; energy supply
required_quality_disclosureIdentity and measurement gaps; boundary coverage; uncertainty; allocation; temporal and geographical representativeness
update_triggerChanged product, route, yield, supply, waste fate, site or representative period

11. Data Sources

Source idTypeReferenceUsed for
epa-water-2004official_guidanceUS EPA, Drinking Water Treatment, EPA 816-F-04-034, June 2004, PDF pp.2–3. https://archive.epa.gov/water/archive/web/pdf/2009_08_28_sdwa_fs_30ann_treatment_web.pdfWater-source differences, flocculation/sedimentation, filtration and disinfection; process description only, not current compliance guidance.
doe-desalinationofficial_guidanceUS DOE, Desalination Basics, web snapshot 1 October 2026, How Does Desalination Work? https://www.energy.gov/cmei/ito/desalination-basicsMembrane and thermal route distinction, permeate and saline concentrate; no performance defaults.
doe-alternative-waterofficial_guidanceUS DOE, Best Management Practice 14: Alternative Water Sources, web snapshot 1 October 2026. https://www.energy.gov/cmei/femp/best-management-practice-14-alternative-water-sourcesReclaimed and alternative water suitability for declared further use.
cpc3-notes-2025official_guidanceUNSD, CPC Version 3.0 Explanatory Notes, 30 June 2025. https://unstats.un.org/unsd/classifications/Econ/Download/In%20Text/CPC_Ver_3.0_Exp_Notes_30Jun2025.pdfClassification scope only; no process quantities.
ef-allocation-2021official_guidanceCommission Recommendation (EU) 2021/2279, Annex I section 4.5, consolidated 30 December 2021. https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:02021H2279-20211230Multifunctionality hierarchy; not a claim of complete PEF conformity.

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 3
Rule IDApplies toRuleSource IDs
boundary_operationssiteThis PCR covers potable or non-potable bulk water suitable for a declared further use, including untreated freshwater abstraction, conventional treatment, membrane or thermal desalination and reclamation of used water. Fix the actual source, treatment train and quality. The supply gate may be the plant meter or a declared network handover; include network pumping, flushing and leakage only for that boundary. Raw seawater as a marketed product, steam/hot water, bottled beverages, carbonated mineral water, distilled-water chemical products and water unsuitable for further use are excluded. Wastewater-treatment service and usable reclaimed-water supply require separate burden and product declarations. For ion exchange, adsorption or additional reclamation steps, add the actual resin, regenerant, activated carbon, residual and pollutant exchanges individually; the candidate cards do not replace a plant audit.epa-water-2004, doe-desalination, doe-alternative-water
boundary_partitionall exchangesInclude actual conditioning, storage, handling and pollution controls through the declared gate. Account for attributable construction and closure with a disclosed lifetime-output basis or justified exclusion and sensitivity. Separate purchased fuel supply from foreground combustion and purchased treatment from site releases.
boundary_completenessinventoryCards define individual likely exchanges and route conditions, not an exhaustive site audit. Add each actual absent chemical, waste, resource, land transformation and pollutant as its own row. Absence, measured zero and unknown must be distinguished.
Allocation rules · 3
Rule IDApplies toRuleSource IDs
allocation_hierarchyjoint productionPrefer process subdivision or defensible system expansion; otherwise use demonstrated physical causality. Use economic allocation only with consistent period, price, currency and sensitivity when physical causality is unavailable. Retain the unallocated inventory.ef-allocation-2021
allocation_productreference and co-productsSeparate raw-water abstraction, treatment, desalination, reuse and distribution meters. For co-produced heat, power or salt, retain unallocated inventories and demonstrated physical relationships. Reclaimed water is not automatically burden-free and avoided freshwater is not an automatic credit; declare the wastewater-treatment service and recycling allocation consistently.
allocation_wastewaste and recyclingClassify each output by physical state and actual fate. A sale does not automatically make a residue a co-product; internal recycling receives no avoided-product credit. Apply treatment burdens once.
Validation rules · 3
Rule IDApplies toRuleSource IDs
validate_referencefinal_productVerify 1 m3, positive D, product state, property/unit and every required qualifier. Each dataset fixes one product and route.
validate_balancesiteClose source-water, product, concentrate, sludge water, backwash, reuse, evaporation, flushing, network losses and stock balances. D is accepted net m3 at the declared gate; record meter temperature. Convert chemical solution and wet sludge masses with measured concentration and moisture. Abstraction is not equal to consumption: disclose receiving basin and returned quantity/quality. Do not convert m3 to kg using an undocumented universal density.
validate_coveragehandoffVerify each applicable exchange, its provider or environmental compartment and final waste fate; identify skipped checks, unresolved identities, missing measurements and upstream gaps. Errors or unassessed mandatory coverage cannot be labelled complete.
Processes and inputs/outputs · 6
Process IDProcess nameInput flowsOutput flows
intakeWater intake and pumping50
conventionalClarification, filtration and disinfection31
membraneMembrane desalination21
thermalThermal desalination21
reuseUsed-water reclamation21
supplySupply metering and declared distribution11

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page