TianGong PCR

Manufacture of complete steel plastic-injection mould tooling

Lifecycle status
Candidate
Content maturity
Authored methodology
Current version
0.1.0Last updated
Readiness
Review required

Methodology and translation states come from the source record; publishing this website does not change their review status.

Content languages

zh-CN · Aligned
Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:44916 · narrower

Source

1. Scope and Applicability

Manufacture of a new complete steel mould for thermoplastic injection moulding: one configured fixed/moving-half set with declared cavity/core, base, guidance, ejection, cooling and gating interfaces. The representative route uses conventional steel inserts and cold runners; a hot runner is included only as an actual installed option. This narrower CPC44916 boundary excludes separately sold bases, inserts and spare parts; foundry boxes/patterns, ingot/metal/carbide/glass/mineral/rubber moulds, blow/compression/extrusion tooling, aluminium moulds, additively manufactured conformal-cooling inserts, refurbishment, injection-moulding machines and external controllers/robots/temperature-control plants. Those routes need explicit expansion. Customer plastic-part production, lifetime shots, mould maintenance/use and end of life are outside. Uddeholm Edition17, March2021 is historical grade-specific manufacturing guidance; the undated HASCO poster is one two-cavity hot-runner example. Neither establishes universal components, steel grades, factory quantities, net mass or service life. Manufacturing mass is not equivalent moulding performance.

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.metal-products-machinery-and-equipment.special-purpose-machinery.plastic-injection-mould-tooling
classification_refsCPC 3.0 44916; narrower candidate scope; no accepted mapping asserted
covered_productsNew complete configured steel thermoplastic injection moulds
excluded_productsStandalone tooling components; other moulding technologies/material routes; moulding machines; customer plastic production and use
representative_productOne complete fixed/moving-half steel tool with conventional inserts and declared cold-runner arrangement; hot runner only if installed
production_routeReceipt and certificate/configuration control; actual stock machining; conditional EDM/heat treatment/finishing; bought-component assembly; actual factory acceptance and dispatch protection
market_stateAccepted complete drained delivery configuration at declared factory gate

3. Reference Flow

FieldValue
WhatManufacture one declared complete steel thermoplastic injection-mould configuration
How much1 kg accepted net complete mould; one complete unit is represented by its physically measured M kg
How wellMeet the actual drawing-specific dimensional, parting/ejection/assembly, cooling leak and applicable hot-runner electrical and tryout acceptance plan. Record actual criteria/results; no universal hardness, roughness, pressure or shot count
How long or cycleOne manufacturing delivery; no customer moulding cycle or lifetime inferred
reference_flow_linkfinished_mould
FieldValue
Reference amount1
Reference product flowMoulding boxes for metal foundry, mould bases, moulding patterns, moulds for metal (except ingot moulds), metal carbides, glass, mineral materials, rubber or plastics da241301-584e-4c9c-baa7-2208878acd1d
Reference flow propertyMass 93a60a56-a3c8-11da-a746-0800200b9a66
Reference unit groupUnits of mass 93a60a57-a4c8-11da-a746-0800200c9a66
Reference unitkg
Required qualifiersTool serial/drawing/BOM revision; complete fixed/moving-half set; cavity count and geometry; steel grades/certificates and delivered heat state; local/bought insert routes; base/guidance/ejection/cooling/gating completeness; runner and installed hot-runner components; supplier internals; actual acceptance criteria/results; drained state/retained lubricant; measured positive M; factory/period/gates; sample/test-water/packaging/transport-fixture/loose-spare/external-controller exclusions

A complete unit means one identified fixed/moving-half set, not an injection-moulding machine or each mould half separately. Declare qualifiers in dataset metadata or equivalent notes.

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
reference_massreference productMass 93a60a56-a3c8-11da-a746-0800200b9a66kgM = accepted net mass of one complete unit of the same configuration in kg; collect using cp_mass.
delivery_completenessdelivery configurationMasskgInclude both mould halves, specified inserts and installed options plus retained delivery lubrication in drained state. Exclude packaging, transport braces/fixtures, removable trial couplings, samples/polymer/test water and separate spares/controllers. If dispatched apart, retain the original accepted complete-set weighing and traceable identity of every included half/part; shipping weights and catalogue masses cannot replace net weighing.
electricity_energyelectricity_machining; electricity_edm; electricity_thermal; electricity_finishing; electricity_assembly; electricity_tryoutNet calorific value 93a60a56-a3c8-11da-a746-0800200c9a66MJRetain metered kWh; convert1 kWh =3.6 MJ. Record source/voltage, stage and actual time/load. Rated press power or invented machining hours cannot establish factory consumption.
fluid_masscoolant; dielectric; nitrogen; diwater; tap_water_machining; tap_water_tryout; spent_emulsion; spent_dielectric; spent_edm_water; test_wastewaterMasskgMeasure the single specified delivered formulation/state or contained waste. Volume requires actual density, temperature/pressure and evidenced conversion; purchased mixtures do not also add constituent inputs. Gaseous nitrogen cannot inherit a liquid-nitrogen identity.
water_resource_volumegroundwaterVolume 93a60a56-a3c8-22da-a746-0800200c9a66m3Meter actual renewable freshwater groundwater abstraction and retain aquifer/site evidence. Resource volume is separate from purchased process-water and exported wastewater mass.

5. System Boundary

Boundary Abstraction

FieldValue
declared_starting_conditionSpecified steel blocks, consumables and separately specified finished mould components received at tooling factory
starting_condition_roleForeground receipts; supplier manufacture/incoming transport separately linked
product_classification_scopeComplete steel thermoplastic injection-mould subset of CPC44916
recursive_input_ruleBought finished bases/inserts replace their stock and local manufacture; purchased complete hot-runner assemblies replace their included heaters/nozzles/manifold. Internal transfers are WIP, not repeated inputs
upstream_dataset_requirementMatch actual steel state, component design/completeness, CNC/EDM/thermal route, chemical formulation, source/geography and supplier/receiver gate
disclosureForeground manufacturing module only. Declare make-or-buy, outsourcing, actual utility/tryout routes and missing supplier/transport/treatment links; no complete cradle-to-gate claim
rule_idapplies_torulesource_ids
boundary_operationsmanufacturingInclude actual receipt inspection, sawing/milling/drilling, conditional sinker/wire EDM, grade-specific heat treatment and surface finishing, dimensional checks, fitting, guiding/ejector/cooling/gate assembly, applicable electrical and leak checks, actual factory tryout, acceptance and attributable rejects/rework. Prehardened stock does not force heat treatment; the supplier delivery state controls the local route. Expand actual washing, solvent/coating, corrosion protection, local electrode making, pumping/deionisation or outsourced service exchanges if present before coverage claims. Initial cards are not a universal BOM.uddeholm-plastic-moulding-2021
boundary_tryouttryoutAcceptance remains required, but physical injection tryout is included only as actually performed. Record press/tool/resin identity, measured feed/energy, cycle count, sample/runner/reject exports, recovered resin and cooling water. Customer production trials after the declared gate are outside. Trial samples are separate outputs; their polymer is never mould mass. No fixed shot count, resin dose or mould lifetime adopted.
boundary_semanticreference_productExisting metal-machining-centre methodology covers the delivered machine and excludes custom-part manufacture. Mouldboard wording in agricultural ploughs refers to a plough component, not injection moulds. No existing material PCR in this baseline covers this complete mould boundary. Keep old classification scaffold/id read-only; this record does not assert mapping acceptance.

6. Process Inventory Structure

Process Map

process_idProcess nameInclusionInclusion conditionRoleQuantitative reference
machiningStock preparation and CNC machiningconditionalActual local milling/drilling of specified steel stockForeground stage; internal WIP remains within moduleper 1 kg reference flow; collected per one accepted finished unit
edmDeclared electrical-discharge machiningconditionalActual sinker or wire-EDM route onlyForeground stage; internal WIP remains within moduleper 1 kg reference flow; collected per one accepted finished unit
thermalDeclared steel heat treatmentconditionalActual grade-specific local electric vacuum/quench/temper routeForeground stage; internal WIP remains within moduleper 1 kg reference flow; collected per one accepted finished unit
finishingDeclared cavity/core finishingconditionalActual drawing-specific grinding/polishingForeground stage; internal WIP remains within moduleper 1 kg reference flow; collected per one accepted finished unit
assemblyConfigured complete mould assemblyrequiredOne declared complete fixed/moving-half setForeground stage; internal WIP remains within moduleper 1 kg reference flow; collected per one accepted finished unit
tryoutFactory inspection and acceptancerequiredModel-specific acceptance; injection tryout only if actually performedForeground stage; internal WIP remains within moduleper 1 kg reference flow; collected per one accepted finished unit
packoutDispatch protectionconditionalActual specified protectionForeground stage; internal WIP remains within moduleper 1 kg reference flow; collected per one accepted finished unit

Process: Stock preparation and CNC machining (machining)

Inputs

Product flows
Prehardened P20 steel mould block (p20_stock)

Only if an actual in-house core/cavity route uses this single certificate-declared grade/state and block geometry. Weigh net received/issued stock and returns, record allowance and actual routing. Purchased finished insert replaces stock and local machining. Historical supplier examples do not make these grades mandatory.

  • Selected flow: Prehardened P20 steel mould block
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_material
  • Sources: uddeholm-plastic-moulding-2021
Soft-annealed H13 steel mould block (h13_stock)

Only if an actual in-house core/cavity route uses this single certificate-declared grade/state and block geometry. Weigh net received/issued stock and returns, record allowance and actual routing. Purchased finished insert replaces stock and local machining. Historical supplier examples do not make these grades mandatory.

  • Selected flow: Soft-annealed H13 steel mould block
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_material
  • Sources:
Low-voltage grid electricity (electricity_machining)

Meter actual stage and attributable rework. This public identity is user-side grid-average AC below1kV; another source or voltage requires a matching separate exchange. Outsourced operations are not also counted as local electricity.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_energy.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_energy
  • Sources:
Emulsifiable mineral-oil cutting-fluid concentrate (coolant)

Only one actual supplier-declared emulsifiable mineral-oil formulation/concentration. Weigh net concentrate make-up; water added locally is separate. Narrow the generic cutting-fluid identity to this actual product and retain SDS/composition. A bought ready-mixed emulsion replaces this concentrate plus dilution-water route. No universal dilution ratio.

  • Selected flow: Cutting Fluid 576d250f-4f36-4385-939d-0f03b8f95a10
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_material
  • Sources:
Supplied drinking-quality tap water (tap_water_machining)

Only actual supplied drinking-quality water for this stage: machining-emulsion preparation or mould leak/cooling tests as applicable. Meter fresh make-up and convert volume with actual density/temperature; exclude internal recirculation and supplier mixture water. No customer cooling-water inventory.

  • Selected flow: Tap water d1e0e36c-07f0-4a75-bdcb-efb5d9e2ac36
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_material
  • Sources:
Elementary flows
Abstracted renewable freshwater groundwater (groundwater)

Only actual factory well abstraction with source/aquifer records confirming renewable freshwater and the declared country/site. Meter m3 and expand pumping/treatment inputs; the same water is not also a tap purchase, and recirculation is not abstraction.

  • Selected flow: ground water 4f462198-40cd-4184-8733-86648a20dc3f
  • Flow property / unit: Volume 93a60a56-a3c8-22da-a746-0800200c9a66 / m3
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_water_resource.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_water_resource
  • Sources:

Outputs

Waste flows
Untreated clean P20 steel mould-block offcut (p20_offcut)

Weigh segregated actual clean offcuts of this single certified alloy exported without treatment. Narrow public steel-offcut identity to this grade; internal reuse is not export and no avoided-primary-steel credit is automatic.

  • Selected flow: Steel scrap, offcuts ae44c4ac-bcd5-4a16-b0a5-d674ffeaab6b
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_waste.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_waste
  • Sources:
Untreated clean H13 steel mould-block offcut (h13_offcut)

Weigh segregated actual clean offcuts of this single certified alloy exported without treatment. Narrow public steel-offcut identity to this grade; internal reuse is not export and no avoided-primary-steel credit is automatic.

  • Selected flow: Steel scrap, offcuts ae44c4ac-bcd5-4a16-b0a5-d674ffeaab6b
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_waste.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_waste
  • Sources:
Clean P20 steel machining chips (p20_chips)

Only actual segregated clean chips of this alloy after the declared separation. Weigh exported mass and document residual contamination; oily chips require another identity/row. The public clean-chip category is narrowed; its yield assumptions are not quantities.

  • Selected flow: Steel scrap, machining chips 7f46756b-6f66-46a7-bbcb-c04727d9d19e
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_waste.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_waste
  • Sources:
Clean H13 steel machining chips (h13_chips)

Only actual segregated clean chips of this alloy after the declared separation. Weigh exported mass and document residual contamination; oily chips require another identity/row. The public clean-chip category is narrowed; its yield assumptions are not quantities.

  • Selected flow: Steel scrap, machining chips 7f46756b-6f66-46a7-bbcb-c04727d9d19e
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_waste.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_waste
  • Sources:
Oil-contaminated P20 steel machining chips (oily_p20_chips)

Only actual exported oily chips with alloy certificate, measured oil/water content, wet mass and receiver record. Distinguish separated fluid and clean chips; no fabricated de-oiling efficiency.

  • Selected flow: Oil-contaminated P20 steel machining chips
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_waste.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_waste
  • Sources:
Spent mineral-oil aqueous cutting emulsion (spent_emulsion)

Weigh the actual contained solution exported to off-site treatment and retain oil concentration, metal contamination and receiver gate. Public spent-coolant identity is narrowed to this emulsion. Internal reuse and metal chips are separate; no default fluid-loss fraction.

  • Selected flow: Spent coolant 62b6a738-fb6a-4570-a95a-9255ec0dcb2b
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_waste.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_waste
  • Sources:

Process: Declared electrical-discharge machining (edm)

Inputs

Product flows
Low-voltage grid electricity (electricity_edm)

Meter actual stage and attributable rework. This public identity is user-side grid-average AC below1kV; another source or voltage requires a matching separate exchange. Outsourced operations are not also counted as local electricity.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_energy.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_energy
  • Sources:
Finished shaped copper sinker-EDM electrode (copper_electrode)

Only if the actual declared EDM route uses this single design/formulation. Weigh net issues or attributable replacement/consumption, retain specification, reuse/remaining stock and served orders. Copper sinker, graphite sinker and brass-wire routes are alternatives according to actual records, not simultaneous mandatory inputs. Purchased shaped electrodes exclude their supplier stock/machining from additional local issues.

  • Selected flow: Finished shaped copper sinker-EDM electrode
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_material
  • Sources:
Finished shaped fine-grain graphite sinker-EDM electrode (graphite_electrode)

Only if the actual declared EDM route uses this single design/formulation. Weigh net issues or attributable replacement/consumption, retain specification, reuse/remaining stock and served orders. Copper sinker, graphite sinker and brass-wire routes are alternatives according to actual records, not simultaneous mandatory inputs. Purchased shaped electrodes exclude their supplier stock/machining from additional local issues.

  • Selected flow: Finished shaped fine-grain graphite sinker-EDM electrode
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_material
  • Sources:
Finished uncoated brass wire-EDM electrode wire (brass_wire)

Only if the actual declared EDM route uses this single design/formulation. Weigh net issues or attributable replacement/consumption, retain specification, reuse/remaining stock and served orders. Copper sinker, graphite sinker and brass-wire routes are alternatives according to actual records, not simultaneous mandatory inputs. Purchased shaped electrodes exclude their supplier stock/machining from additional local issues.

  • Selected flow: Finished uncoated brass wire-EDM electrode wire
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_material
  • Sources:
Formulated mineral-oil sinker-EDM dielectric fluid (dielectric)

Only if the actual declared EDM route uses this single design/formulation. Weigh net issues or attributable replacement/consumption, retain specification, reuse/remaining stock and served orders. Copper sinker, graphite sinker and brass-wire routes are alternatives according to actual records, not simultaneous mandatory inputs. Purchased shaped electrodes exclude their supplier stock/machining from additional local issues.

  • Selected flow: Formulated mineral-oil sinker-EDM dielectric fluid
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_material
  • Sources:
Finished cellulose sinker-EDM oil filter cartridge (filter)

Only if the actual declared EDM route uses this single design/formulation. Weigh net issues or attributable replacement/consumption, retain specification, reuse/remaining stock and served orders. Copper sinker, graphite sinker and brass-wire routes are alternatives according to actual records, not simultaneous mandatory inputs. Purchased shaped electrodes exclude their supplier stock/machining from additional local issues.

  • Selected flow: Finished cellulose sinker-EDM oil filter cartridge
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_material
  • Sources:
Purchased deionised wire-EDM process water (diwater)

Only actual purchased deionised water produced by ion exchange or reverse osmosis, matching the public route. Weigh fresh make-up; internal circulation is excluded. On-site deionisation replaces purchase with actual feed water, resin/membrane and energy; do not duplicate both gates. Record actual conductivity criterion, not a universal purity.

  • Selected flow: Deionised water 5b3acbab-2518-4406-8736-d21f222d757a
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_material
  • Sources:

Outputs

Waste flows
Spent mineral-oil sinker-EDM dielectric fluid (spent_dielectric)

Only actual segregated exports to the documented receiver. Weigh this one waste stream and retain composition, alloy/electrode particles, oil/water content and wet/dry state. Internal recovery and retained process fluid are not export; another waste composition needs a separate row.

  • Selected flow: Spent mineral-oil sinker-EDM dielectric fluid
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_waste.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_waste
  • Sources:
Spent aqueous wire-EDM process water (spent_edm_water)

Only actual segregated exports to the documented receiver. Weigh this one waste stream and retain composition, alloy/electrode particles, oil/water content and wet/dry state. Internal recovery and retained process fluid are not export; another waste composition needs a separate row.

  • Selected flow: Spent aqueous wire-EDM process water
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_waste.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_waste
  • Sources:
Spent cellulose sinker-EDM oil filter cartridge (spent_filter)

Only actual segregated exports to the documented receiver. Weigh this one waste stream and retain composition, alloy/electrode particles, oil/water content and wet/dry state. Internal recovery and retained process fluid are not export; another waste composition needs a separate row.

  • Selected flow: Spent cellulose sinker-EDM oil filter cartridge
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_waste.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_waste
  • Sources:

Process: Declared steel heat treatment (thermal)

Inputs

Product flows
Low-voltage grid electricity (electricity_thermal)

Meter actual stage and attributable rework. This public identity is user-side grid-average AC below1kV; another source or voltage requires a matching separate exchange. Outsourced operations are not also counted as local electricity.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_energy.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_energy
  • Sources:
Supplied gaseous nitrogen for mould-steel quenching (nitrogen)

Only an actual nitrogen-gas quench procedure at this site. Weigh gas or use evidenced pressure/temperature/density conversion; liquid supply and on-site vaporisation require their own separate boundary. No compulsory quench gas, pressure, temperature or steel-treatment recipe.

  • Selected flow: Supplied gaseous nitrogen for mould-steel quenching
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_material
  • Sources:

Outputs

Process: Declared cavity/core finishing (finishing)

Inputs

Product flows
Low-voltage grid electricity (electricity_finishing)

Meter actual stage and attributable rework. This public identity is user-side grid-average AC below1kV; another source or voltage requires a matching separate exchange. Outsourced operations are not also counted as local electricity.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_energy.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_energy
  • Sources:
Diamond polishing paste with mineral-oil carrier (diamond_paste)

Only one actual supplier-declared formulation/particle grade or disc binder/design. Weigh net paste issues or measured disc replacement to served orders, retain composition and actual surface requirement. A required optical finish is model-specific; no mandatory polish route or universal abrasive rate.

  • Selected flow: Diamond polishing paste with mineral-oil carrier
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_material
  • Sources:
Finished aluminium-oxide abrasive disc (abrasive_disc)

Only one actual supplier-declared formulation/particle grade or disc binder/design. Weigh net paste issues or measured disc replacement to served orders, retain composition and actual surface requirement. A required optical finish is model-specific; no mandatory polish route or universal abrasive rate.

  • Selected flow: Finished aluminium-oxide abrasive disc
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_material
  • Sources:

Outputs

Waste flows
Spent aluminium-oxide abrasive disc (spent_disc)

Weigh actual exported disc with binder/abrasive/adherent steel recorded; narrow public polishing-media category to this one design and keep captured dust separate.

  • Selected flow: Waste polishing media cdb1838e-d3ec-41e1-87ee-627b9ce95e88
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_waste.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_waste
  • Sources:
Captured dry tool-steel polishing dust (captured_dust)

Only actual contained dust exported to a receiver; record single alloy, abrasive contamination and dry state. This is not airborne particulate or clean offcut.

  • Selected flow: Captured dry tool-steel polishing dust
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_waste.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_waste
  • Sources:
Elementary flows
Particulate emitted to air, size unspecified (air_particulate)

Only if actual post-control monitoring confirms emitted particulate mass, unspecified size and air subcompartment. Pair concentration and exhaust volume on the same sampling basis. Captured dust is separate; specific particle fractions need matching identities. Grinding/polishing alone does not prove emission.

  • Selected flow: Particulate matter, particle size unspecified 0ce3dedb-caca-407b-a856-a90470eb8ec0
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_emission.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_emission
  • Sources:

Process: Configured complete mould assembly (assembly)

Inputs

Product flows
Low-voltage grid electricity (electricity_assembly)

Meter actual stage and attributable rework. This public identity is user-side grid-average AC below1kV; another source or voltage requires a matching separate exchange. Outsourced operations are not also counted as local electricity.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_energy.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_energy
  • Sources:
Finished steel injection-mould base assembly (mould_base)

Only one actual complete bought base, with plate stack, guiding/ejection inclusions, steel grade and measured delivered mass declared. Narrow the broad mould/base public category to this one item, not a complete cavity-equipped mould. Exclude included plates/pillars from additional issues; local base fabrication instead needs stock and machining expansion.

  • Selected flow: Moulding boxes for metal foundry, mould bases, moulding patterns, moulds for metal (except ingot moulds), metal carbides, glass, mineral materials, rubber or plastics da241301-584e-4c9c-baa7-2208878acd1d
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_parts.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_parts
  • Sources: hasco-injection-mould-nut
Finished CNC-milled P20 steel cavity insert (cavity_insert)

Only one separately bought pre-assembly CNC-milled/drilled insert of the actual declared prehardened P20 grade/design. Weigh delivered kg and retain supplier completeness; narrow the public machined-component identity to this role. An EDM/thermal/other supplier route requires a matching identity; locally machined WIP is internal, not this input. No machining step-time-to-mass factor.

  • Selected flow: Machined mould/tooling components 1a185678-4878-4d8d-b58e-6fc5fd0682e1
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_parts.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_parts
  • Sources:
Finished CNC-milled P20 steel core insert (core_insert)

Only one separately bought pre-assembly CNC-milled/drilled insert of the actual declared prehardened P20 grade/design. Weigh delivered kg and retain supplier completeness; narrow the public machined-component identity to this role. An EDM/thermal/other supplier route requires a matching identity; locally machined WIP is internal, not this input. No machining step-time-to-mass factor.

  • Selected flow: Machined mould/tooling components 1a185678-4878-4d8d-b58e-6fc5fd0682e1
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_parts.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_parts
  • Sources:
Finished hardened-steel mould guide pillar (guide_pillar)

Only one actual separately supplied design installed in this configuration. Retain part number, material/thermal state, dimensions, quantity, measured mass and included subparts. Hot-runner items are conditional and exclude supplied heater/sensor internals from another issue. Actual cold-runner, cooling, side-action/ejection designs determine applicability; no universal HASCO component count or rubber chemistry.

  • Selected flow: Finished hardened-steel mould guide pillar
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_parts.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_parts
  • Sources: hasco-injection-mould-nut
Finished hardened-steel mould guide bush (guide_bush)

Only one actual separately supplied design installed in this configuration. Retain part number, material/thermal state, dimensions, quantity, measured mass and included subparts. Hot-runner items are conditional and exclude supplied heater/sensor internals from another issue. Actual cold-runner, cooling, side-action/ejection designs determine applicability; no universal HASCO component count or rubber chemistry.

  • Selected flow: Finished hardened-steel mould guide bush
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_parts.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_parts
  • Sources: hasco-injection-mould-nut
Finished steel mould ejector pin (ejector_pin)

Only one actual separately supplied design installed in this configuration. Retain part number, material/thermal state, dimensions, quantity, measured mass and included subparts. Hot-runner items are conditional and exclude supplied heater/sensor internals from another issue. Actual cold-runner, cooling, side-action/ejection designs determine applicability; no universal HASCO component count or rubber chemistry.

  • Selected flow: Finished steel mould ejector pin
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_parts.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_parts
  • Sources: hasco-injection-mould-nut
Finished steel mould sprue bushing (sprue_bush)

Only one actual separately supplied design installed in this configuration. Retain part number, material/thermal state, dimensions, quantity, measured mass and included subparts. Hot-runner items are conditional and exclude supplied heater/sensor internals from another issue. Actual cold-runner, cooling, side-action/ejection designs determine applicability; no universal HASCO component count or rubber chemistry.

  • Selected flow: Finished steel mould sprue bushing
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_parts.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_parts
  • Sources: hasco-injection-mould-nut
Finished steel mould locating ring (locating_ring)

Only one actual separately supplied design installed in this configuration. Retain part number, material/thermal state, dimensions, quantity, measured mass and included subparts. Hot-runner items are conditional and exclude supplied heater/sensor internals from another issue. Actual cold-runner, cooling, side-action/ejection designs determine applicability; no universal HASCO component count or rubber chemistry.

  • Selected flow: Finished steel mould locating ring
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_parts.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_parts
  • Sources: hasco-injection-mould-nut
Finished steel hexagon-socket head cap screw (cap_screw)

Only one actual separately supplied design installed in this configuration. Retain part number, material/thermal state, dimensions, quantity, measured mass and included subparts. Hot-runner items are conditional and exclude supplied heater/sensor internals from another issue. Actual cold-runner, cooling, side-action/ejection designs determine applicability; no universal HASCO component count or rubber chemistry.

  • Selected flow: Finished steel hexagon-socket head cap screw
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_parts.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_parts
  • Sources:
Finished NBR rubber cooling-channel O-ring (o_ring)

Only one actual separately supplied design installed in this configuration. Retain part number, material/thermal state, dimensions, quantity, measured mass and included subparts. Hot-runner items are conditional and exclude supplied heater/sensor internals from another issue. Actual cold-runner, cooling, side-action/ejection designs determine applicability; no universal HASCO component count or rubber chemistry.

  • Selected flow: Finished NBR rubber cooling-channel O-ring
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_parts.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_parts
  • Sources:
Finished steel mould-cooling quick coupling (cooling_coupling)

Only one actual separately supplied design installed in this configuration. Retain part number, material/thermal state, dimensions, quantity, measured mass and included subparts. Hot-runner items are conditional and exclude supplied heater/sensor internals from another issue. Actual cold-runner, cooling, side-action/ejection designs determine applicability; no universal HASCO component count or rubber chemistry.

  • Selected flow: Finished steel mould-cooling quick coupling
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_parts.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_parts
  • Sources:
Finished steel hot-runner manifold assembly (hot_manifold)

Only one actual separately supplied design installed in this configuration. Retain part number, material/thermal state, dimensions, quantity, measured mass and included subparts. Hot-runner items are conditional and exclude supplied heater/sensor internals from another issue. Actual cold-runner, cooling, side-action/ejection designs determine applicability; no universal HASCO component count or rubber chemistry.

  • Selected flow: Finished steel hot-runner manifold assembly
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_parts.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_parts
  • Sources: hasco-injection-mould-nut
Finished hot-runner nozzle assembly (hot_nozzle)

Only one actual separately supplied design installed in this configuration. Retain part number, material/thermal state, dimensions, quantity, measured mass and included subparts. Hot-runner items are conditional and exclude supplied heater/sensor internals from another issue. Actual cold-runner, cooling, side-action/ejection designs determine applicability; no universal HASCO component count or rubber chemistry.

  • Selected flow: Finished hot-runner nozzle assembly
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_parts.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_parts
  • Sources: hasco-injection-mould-nut
Finished type-K hot-runner thermocouple (thermocouple)

Only one actual separately supplied design installed in this configuration. Retain part number, material/thermal state, dimensions, quantity, measured mass and included subparts. Hot-runner items are conditional and exclude supplied heater/sensor internals from another issue. Actual cold-runner, cooling, side-action/ejection designs determine applicability; no universal HASCO component count or rubber chemistry.

  • Selected flow: Finished type-K hot-runner thermocouple
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_parts.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_parts
  • Sources:
Finished non-carbon tubular hot-runner heating resistor (heater)

Only one actual separately supplied metal-sheathed non-carbon resistor design; record electrical rating, measured mass and installed position. Narrow public heater category to this design and exclude heater already supplied inside manifold/nozzle assemblies. Rating is configuration, not mass or energy consumed.

  • Selected flow: Electric heating resistors, except of carbon 991da6ee-1a8a-4e77-8f9c-c50615e255e7
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_parts.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_parts
  • Sources: hasco-injection-mould-nut
Lithium-soap mineral-oil mould lubricating grease (grease)

Only actual factory-added specified grease, measured as net issues/returns. Exclude supplier-prelubricated internals and record retained delivered lubrication in M; customer use-phase lubrication is outside.

  • Selected flow: Lithium-soap mineral-oil mould lubricating grease
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_material
  • Sources:

Outputs

Process: Factory inspection and acceptance (tryout)

Inputs

Product flows
Low-voltage grid electricity (electricity_tryout)

Meter actual stage and attributable rework. This public identity is user-side grid-average AC below1kV; another source or voltage requires a matching separate exchange. Outsourced operations are not also counted as local electricity.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_energy.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_energy
  • Sources:
Supplied drinking-quality tap water (tap_water_tryout)

Only actual supplied drinking-quality water for this stage: machining-emulsion preparation or mould leak/cooling tests as applicable. Meter fresh make-up and convert volume with actual density/temperature; exclude internal recirculation and supplier mixture water. No customer cooling-water inventory.

  • Selected flow: Tap water d1e0e36c-07f0-4a75-bdcb-efb5d9e2ac36
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_material
  • Sources:
Unfilled polypropylene granulate for factory mould tryout (trial_pp)

Only when actual acceptance tryout uses one supplier-declared unfilled PP grade. Retain grade/homopolymer-or-copolymer identity in metadata, certificates, measured net feed, recovered material and actual cycles. Narrow public polymerisation-granulate category to this grade; another polymer/blend needs separate identity. No customer production shot count or lifetime feed factor.

  • Selected flow: polypropylene granulate (PP) 4f19f11d-7b3b-11dd-ad8b-0800200c9a66
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_material
  • Sources:

Outputs

Product flows
Factory injection-moulded unfilled PP acceptance sample (trial_sample)

Only actual separately weighed acceptance samples leaving the tooling-manufacture module to declared customer/inspection/archive gate. Retain sample shape/grade, disposition and batch count; samples are not mould mass. No commercial co-product or recycling credit is inferred. Samples retained inside the module are internal WIP instead.

  • Selected flow: Factory injection-moulded unfilled PP acceptance sample
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_trial_output.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_trial_output
  • Sources:
Accepted complete configured steel plastic-injection mould (finished_mould)

Reference output after actual dimensional, assembly/parting/ejection, cooling leak, hot-runner electrical and model-specific acceptance as applicable. One complete fixed/moving-half set with declared inserts and installed options; subtract no invented sample/water mass. Weigh delivered drained state with retained lubricant; exclude transport packaging/fixtures, test samples, removable test couplings and separate controllers/spares. Public category is narrowed to this complete thermoplastic tool.

  • Selected flow: Moulding boxes for metal foundry, mould bases, moulding patterns, moulds for metal (except ingot moulds), metal carbides, glass, mineral materials, rubber or plastics da241301-584e-4c9c-baa7-2208878acd1d
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: 1 kg
  • Value mode: fixed_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: collected_record
  • Collection protocol: cp_mass
  • Sources: hasco-injection-mould-nut
Waste flows
Clean unfilled PP factory-tryout runner waste (pp_runner)

Only actual segregated waste from the declared PP tryout, exported to a recorded mechanical-recycling receiver matching the public route. Weigh this single physical waste separately and retain resin grade/contamination; internal regrind is not export. Treatment is separately linked, with no automatic avoided-resin credit.

  • Selected flow: Polypropylene Wastes 88215d1b-e6b6-4ec7-af7f-83375e80637b
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_waste.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_waste
  • Sources:
Rejected unfilled PP factory-tryout specimen waste (pp_reject)

Only actual segregated waste from the declared PP tryout, exported to a recorded mechanical-recycling receiver matching the public route. Weigh this single physical waste separately and retain resin grade/contamination; internal regrind is not export. Treatment is separately linked, with no automatic avoided-resin credit.

  • Selected flow: Polypropylene Wastes 88215d1b-e6b6-4ec7-af7f-83375e80637b
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_waste.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_waste
  • Sources:
Contained water from mould-cooling leak testing (test_wastewater)

Only actual drained water exported to external treatment; measure solution mass and record contamination/receiver. Reused cooling water is internal; direct environmental discharge needs separate species and medium. No default test-water volume.

  • Selected flow: Contained water from mould-cooling leak testing
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_waste.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_waste
  • Sources:

Process: Dispatch protection (packout)

Inputs

Product flows
Finished wooden dispatch pallet (wood_pallet)

Only actual dispatch protection of this single specified product. Weigh net attributable issues and exclude from M. Pallet design/species/moisture/treatment and reuse are declared; foil is non-adhesive/unreinforced; cardboard is recycled-fibre C-flute with at least80% fibre. A different specification needs a separate compatible row, without universal packing mass or single-use assumption.

  • Selected flow: Pallets, box pallets and other load boards, of wood, pallet collars of wood 4b49871e-95be-4e0c-9223-9902f9eaa763
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_material
  • Sources:
Non-cellular LDPE protective foil (ldpe_film)

Only actual dispatch protection of this single specified product. Weigh net attributable issues and exclude from M. Pallet design/species/moisture/treatment and reuse are declared; foil is non-adhesive/unreinforced; cardboard is recycled-fibre C-flute with at least80% fibre. A different specification needs a separate compatible row, without universal packing mass or single-use assumption.

  • Selected flow: Low-density polyethylene foil (PE-LD) 2cecd3a7-d90e-44b4-aec5-1d9dfb907477
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_material
  • Sources:
C-flute corrugated cardboard (cardboard)

Only actual dispatch protection of this single specified product. Weigh net attributable issues and exclude from M. Pallet design/species/moisture/treatment and reuse are declared; foil is non-adhesive/unreinforced; cardboard is recycled-fibre C-flute with at least80% fibre. A different specification needs a separate compatible row, without universal packing mass or single-use assumption.

  • Selected flow: Corrugated cardboard 8bde297e-98df-463f-bcb4-0db52bf6e0b5
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Apply normalize_mass to q_item; reference_mass; cp_material.
  • Value mode: calculated_value
  • Specificity: product_specific
  • Normalization basis: per 1 kg reference flow; collected per one accepted finished unit
  • Basis kind: reference_flow
  • Evidence kind: calculated_from_collection
  • Collection protocol: cp_material
  • Sources:

Outputs

7. Allocation and Co-product Handling

rule_idapplies_torulesource_ids
allocation_causalshared_operationsSeparate orders/routes by direct measurement first. Reconcile shared measured CNC/EDM/finishing and assembly/tryout utility totals using actual stage time/load and material issues with documented causal drivers, including idle, rejects and rework. For a real thermal batch, record loaded steel mass, grade/recipe and actual furnace cycle; justify allocation to served orders, not a universal furnace factor. Report uncertainty and sensitivity where the driver is imperfect.
allocation_trialtryoutActual acceptance tryout belongs to this mould manufacturing order. Track samples, runner/reject waste, recovered resin and cooling-fluid reuse separately; no automatic commercial co-product or avoided-polymer credit. If samples have a real commercial function, declare the changed multi-output boundary and evidence-based allocation before use. Reusable electrodes/filter life and retained fluid are attributed from actual replacement/served-order records, not one full item consumed per mould.
allocation_balancemanufacturing_batchReconcile received stock, finished installed mass, exports, WIP and internal recovery for the same period/configuration. Attribute rework/reject burden to accepted complete units. Scrap exits at its recorded receiver gate; no automatic substitution credit, equal-per-unit or sales-value allocation.

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_masstryoutreference_productcalibrated net weighingserial; configuration; accepted net mass M; both halves/options; scale/tare; acceptance; drained state; excluded packagingWeigh the accepted complete unit on a calibrated scale, excluding transport packaging; reconcile the same configuration and acceptance record.kgeach complete accepted configurationsame declared production period; disclose gapsdeclared tooling manufacturing siteaccepted net mass per unitscale calibration; net weigh ticket; complete-set acceptance
cp_configurationassembly; tryoutconfigurationdrawing/BOM and route ledgerserial; cavity/core/base; grade/heat certificates; cavity count; guidance/ejection/cooling/gate; runner/options; make-or-buy; actual finish/acceptance; site/periodCrosswalk every actual drawing/BOM item and operation to an atomic exchange or justified exclusion. Verify supplier internals and the complete fixed/moving-half set, not brochure component counts. Record actual tolerances, hardness/surface and test results without universal thresholds.kgeach drawing/build revisionsame declared production period; disclose gapsdeclared tooling manufacturing siteone traceable complete configurationdrawing; certificates; signed routing/BOM and inspection
cp_materialmachining; edm; thermal; finishing; assembly; tryout; packoutindividual stock/consumablenet issues and weighingone material/design; grade/state/formulation; delivered mass; issues/returns; reuse; density/temperature/pressure if volume; served orders; accepted countWeigh actual net stock, fluids, electrodes, abrasive, grease, resin and protection separately. Record composition/state and actual reuse/replacement. Convert volume only with actual evidenced density/conditions; exclude constituents of bought mixtures. Trial resin feed and returned material are measured, not inferred from shots.kgeach issue/return and production batchsame declared production period; disclose gapsdeclared tooling manufacturing siteattributable net material mass / accepted units of the same configurationscale; certificates/SDS; inventory and served-order ledger
cp_partsassemblyindividual installed componentweighing and supplier completenesspart/design; steel state; mass; supplier-included internals; installed count; accepted count; CNC-only route if selectedWeigh supplied finished components or verify actual lot-specific part mass/count records. Reconcile base, separate CNC inserts, guidance/ejection, seals/cooling, gate and installed hot runner. Exclude parts included in purchased assemblies and local WIP; no standard catalogue component-mass factor.kgeach supplied lot and build batchsame declared production period; disclose gapsdeclared tooling manufacturing siteattributable installed component mass / accepted units of the same configurationscale; supplier boundary; part certificates and actual BOM
cp_energymachining; edm; thermal; finishing; assembly; tryoutelectricitymeter and causal-driver ledgerstage; source/voltage; metered kWh; interval; shared total; actual load/time; idle/rework; accepted countMeter actual stages and press/tool tryout only as performed. Convert1 kWh =3.6 MJ. Attribute shared totals with measured causal drivers and reconcile idle/rework/rejects. Rated power or supplier machining-time examples are not energy quantities.MJeach actual stage interval/batchsame declared production period; disclose gapsdeclared tooling manufacturing siteattributable electrical energy / accepted units of the same configurationmeter calibration; bills; stage/load allocation records
cp_wastemachining; edm; finishing; tryoutindividual exported wastesegregated weighing and receiver receiptsone waste; alloy/composition; wet/dry; oil/water contamination; exported mass; internal recovery; receiver/treatment; accepted countWeigh each actual alloy offcut, clean/oily chip, spent fluid/filter/disc, captured dust, PP runner/reject and contained test water separately. Retain actual concentration/contamination and treatment gate. Clean-chip identity excludes oily chips; selected PP waste requires mechanical-recycling receiver. Reuse is not export; measured direct discharge needs individual species/medium expansion.kgeach export and reconciled batchsame declared production period; disclose gapsdeclared tooling manufacturing siteattributable exported waste mass / accepted units of the same configurationscale; composition; receiver/treatment receipts
cp_emissionfinishingsingle air particulatepost-control monitoringsubstance; medium/submedium; particle size; concentration; exhaust volume; sampling basis; interval; background; accepted countOnly actual post-control emitted particulate: pair mass concentration and exhaust volume on the same sampling basis, with corrections and uncertainty. Confirm unspecified size/air medium for this UUID. Captured dust is not emission. Expand a specific fraction or other measured substance separately; no mandatory release factor.kgrepresentative actual emitting intervalssame declared production period; disclose gapsdeclared tooling manufacturing siteattributable measured particulate mass / accepted units of the same configurationmonitoring; sampler/flow calibration; medium and size evidence
cp_water_resourcemachininggroundwaterwell meter and source recordaquifer renewability/freshwater; site/country; m3; interval; pumping/treatment; stage use/reuse; accepted countMeter actual renewable freshwater groundwater at the factory; verify aquifer qualification and separately expand pumping/treatment. Internal circulation is not abstraction; the same water cannot also be a tap-water purchase.m3each metered interval/batchsame declared production period; disclose gapsdeclared tooling manufacturing siteattributable abstracted water volume / accepted units of the same configurationmeter; aquifer/site record; stage water balance
cp_trial_outputtryoutone actual PP acceptance-sample outputseparate weighing and dispositionsample shape/resin grade; batch; actual exported kg; retained samples; runner/reject separation; receiver; accepted countWeigh the single specified acceptance-sample product leaving this module; record actual customer/inspection/archive gate. Retained sample WIP and exported PP waste are separate. No sample mass is included in mould M and no commercial output function is inferred.kgeach actual acceptance-sample exportsame declared production period; disclose gapsdeclared tooling manufacturing siteattributable exported sample mass / accepted units of the same configurationscale; resin/sample identity; acceptance and disposition record

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
normalize_massall inventory rowsq_ref = q_item / M; q_item = exchange amount per one accepted finished unit; q_ref = exchange amount per 1 kg reference flow.q_item; M; cp_massq_ref

Data Quality Requirements

requirement_idApplies toRequirementEvidence
quality_configurationall inventory rowsUse identical configuration, period and accepted count for positive measured M and exchange numerators. Reconcile fixed/moving halves, installed inserts/runner/options, supplied internals and make-or-buy. Retain grade/state, actual finish/acceptance, trial feeds/samples/recovery, drained delivery and uncertainty.cp_configuration; cp_mass; cp_parts; cp_material; cp_trial_output
quality_coverageinventory_and_linksDisclose missing BOM items/routes, measurements, UUIDs and supplier/transport/treatment links. Site evidence controls optional EDM/thermal/finishing/physical tryout. No universal material grade, machining yield, heat recipe, resin dose, shot count, emission or lifetime factor.cp_configuration; cp_energy; cp_waste; cp_emission; cp_water_resource
quality_sourcesdesign_evidenceUddeholm Edition17 March2021 pp.10–12 provides historical supplier-grade machining/thermal/finishing examples, not current universal prescriptions. HASCO undated one-page poster shows one two-cavity hot-runner tool; PDF creation metadata is not publication date. Neither fixes actual BOM quantities, steel chemistry, required hot runner, measured M or life.uddeholm-plastic-moulding-2021; hasco-injection-mould-nut

9. Validation Rules

rule_idapplies_torulesource_ids
validation_referencereference_flowRequire one complete fixed/moving-half configuration, positive physically measured M in kg and cp_mass weighing/acceptance record. Reference output is1kg; normalize every other kg, MJ or m3 exchange using normalize_mass. Keep drained-state and delivery exclusions explicit.
validation_bominventoryCheck every actual steel stock or finished base/insert, guide/ejector, cooling/seal/gating and installed hot-runner item against BOM and route records. Check local/bought alternatives, exact CNC-only selected route, fluid/electrode reuse, sample/waste balances, rejects/rework and receiver gates. Expand absent actual cards before asserting complete coverage.
validation_identityall inventory rowsVerify public flow type, grade/formulation, reference property/unit group, actual state/route/completeness and official localized name. Clean chips exclude oily chips; graphite steelmaking electrodes exclude EDM electrodes; liquid nitrogen excludes gaseous product. Groundwater resource, purchased process water and contained wastewater are distinct. Air particulate is not captured dust.
validation_claimsdataset_claimsNo complete cradle-to-gate claim without actual route and linked supplier/transport/receiver coverage. Tool manufacturing mass does not prove cavity throughput, plastic-part equivalence, lifetime, regulatory conformity or methodology approval. Independent scientific review remains pending.

10. Published Dataset Profile

FieldValue
dataset_roleConfigured foreground complete steel plastic-injection mould manufacturing module; heading does not assert publication
downstream_usesecondary_dataset; background_dataset
allowed_useSame complete configured tooling manufacture scaled by measured M; linked upstream/transport/treatment separately disclosed
excluded_useCustomer plastic-part manufacture, use/lifetime, standalone components, other mould technologies/material routes and methodology approval
required_metadataAll reference qualifiers; drawing/BOM/cavity/runner revision; steel certificates/heat states; actual make-or-buy and supplied internals; EDM/thermal/finish/tryout routes; measured complete-set M and delivery exclusions; actual criteria/results; trial resin/sample/waste/recovery; site/period/gates, causal allocation and linked suppliers/receivers
required_quality_disclosureMissing identities/measurements/BOM/routes/links; uncertainty, actual reuse/rejects/rework, allocation and historical/undated source limitations
update_triggerTool/cavity/runner/BOM, steel delivery state, supplier completeness, machining/EDM/thermal/finish route, make-or-buy, tryout/acceptance, site/period, reuse or allocation change

11. Data Sources

Source idTypeReferenceUsed for
uddeholm-plastic-moulding-2021handbookUddeholm, TOOL STEELS FOR PLASTIC MOULDING, Edition17,03.2021 (edition statement physical p.2); physical/printed pp.10–12. https://www.uddeholm.com/app/uploads/sites/230/2024/05/Tech-Uddeholm-Steel-for-moulds-EN-1.pdfHistorical manufacturer-grade delivery/machining choice, prehardened versus soft-annealed thermal distinction, finish dependence and conditional EDM surface effects. Wire-EDM example concerns extrusion dies, not proof every injection mould needs wire EDM. No temperatures, hardness, distortion, costs, processing quantities, net mould mass or life adopted. URL folder date is not edition date.
hasco-injection-mould-nuthandbookHASCO, 2-cavity injection moulding tool “Nut”, undated one-page annotated poster, physical p.1 (unnumbered). https://media.hasco.com/marketing/Content/Mediathek/Poster/Form/Form_POST_EN.pdfOne specific fixed/moving-half, guide/ejector/base and hot-runner component example. Used to identify configuration questions, not universal BOM counts/chemistries, mandatory hot runner, factory inputs, mould mass or life. PDF creation metadata2022 is not asserted as publication year.

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 3
Rule IDApplies toRuleSource IDs
boundary_operationsmanufacturingInclude actual receipt inspection, sawing/milling/drilling, conditional sinker/wire EDM, grade-specific heat treatment and surface finishing, dimensional checks, fitting, guiding/ejector/cooling/gate assembly, applicable electrical and leak checks, actual factory tryout, acceptance and attributable rejects/rework. Prehardened stock does not force heat treatment; the supplier delivery state controls the local route. Expand actual washing, solvent/coating, corrosion protection, local electrode making, pumping/deionisation or outsourced service exchanges if present before coverage claims. Initial cards are not a universal BOM.uddeholm-plastic-moulding-2021
boundary_tryouttryoutAcceptance remains required, but physical injection tryout is included only as actually performed. Record press/tool/resin identity, measured feed/energy, cycle count, sample/runner/reject exports, recovered resin and cooling water. Customer production trials after the declared gate are outside. Trial samples are separate outputs; their polymer is never mould mass. No fixed shot count, resin dose or mould lifetime adopted.
boundary_semanticreference_productExisting metal-machining-centre methodology covers the delivered machine and excludes custom-part manufacture. Mouldboard wording in agricultural ploughs refers to a plough component, not injection moulds. No existing material PCR in this baseline covers this complete mould boundary. Keep old classification scaffold/id read-only; this record does not assert mapping acceptance.
Allocation rules · 3
Rule IDApplies toRuleSource IDs
allocation_causalshared_operationsSeparate orders/routes by direct measurement first. Reconcile shared measured CNC/EDM/finishing and assembly/tryout utility totals using actual stage time/load and material issues with documented causal drivers, including idle, rejects and rework. For a real thermal batch, record loaded steel mass, grade/recipe and actual furnace cycle; justify allocation to served orders, not a universal furnace factor. Report uncertainty and sensitivity where the driver is imperfect.
allocation_trialtryoutActual acceptance tryout belongs to this mould manufacturing order. Track samples, runner/reject waste, recovered resin and cooling-fluid reuse separately; no automatic commercial co-product or avoided-polymer credit. If samples have a real commercial function, declare the changed multi-output boundary and evidence-based allocation before use. Reusable electrodes/filter life and retained fluid are attributed from actual replacement/served-order records, not one full item consumed per mould.
allocation_balancemanufacturing_batchReconcile received stock, finished installed mass, exports, WIP and internal recovery for the same period/configuration. Attribute rework/reject burden to accepted complete units. Scrap exits at its recorded receiver gate; no automatic substitution credit, equal-per-unit or sales-value allocation.
Validation rules · 4
Rule IDApplies toRuleSource IDs
validation_referencereference_flowRequire one complete fixed/moving-half configuration, positive physically measured M in kg and cp_mass weighing/acceptance record. Reference output is1kg; normalize every other kg, MJ or m3 exchange using normalize_mass. Keep drained-state and delivery exclusions explicit.
validation_bominventoryCheck every actual steel stock or finished base/insert, guide/ejector, cooling/seal/gating and installed hot-runner item against BOM and route records. Check local/bought alternatives, exact CNC-only selected route, fluid/electrode reuse, sample/waste balances, rejects/rework and receiver gates. Expand absent actual cards before asserting complete coverage.
validation_identityall inventory rowsVerify public flow type, grade/formulation, reference property/unit group, actual state/route/completeness and official localized name. Clean chips exclude oily chips; graphite steelmaking electrodes exclude EDM electrodes; liquid nitrogen excludes gaseous product. Groundwater resource, purchased process water and contained wastewater are distinct. Air particulate is not captured dust.
validation_claimsdataset_claimsNo complete cradle-to-gate claim without actual route and linked supplier/transport/receiver coverage. Tool manufacturing mass does not prove cavity throughput, plastic-part equivalence, lifetime, regulatory conformity or methodology approval. Independent scientific review remains pending.
Processes and inputs/outputs · 7
Process IDProcess nameInput flowsOutput flows
machiningStock preparation and CNC machining66
edmDeclared electrical-discharge machining73
thermalDeclared steel heat treatment20
finishingDeclared cavity/core finishing33
assemblyConfigured complete mould assembly170
tryoutFactory inspection and acceptance35
packoutDispatch protection30

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page