TianGong PCR产品类别规则

Diodes, transistors and similar semi-conductor devices; photosensitive semi-conductor devices; light emitting diodes; mounted piezo-electric crystals

Diodes, transistors and similar semi-conductor devices; photosensitive semi-conductor devices; light emitting diodes; mounted piezo-electric crystals: This PCR applies…

Lifecycle status
Candidate
Content maturity
Authored methodology
Current version
No published version
Readiness
Review required
Last updated

Methodology and translation states come from the source record; publishing this website does not change their review status.

Content languages

zh-CN · Aligned
Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:47150 · exact

Source

1. Scope and Applicability

This PCR applies to foreground data packages for finished devices within the reviewed semantic boundary of discrete semiconductor devices, photosensitive semiconductor devices, photovoltaic cells and cell assemblies, light-emitting diodes, and mounted piezo-electric crystals. A conforming data package represents one declared device family, material system, production route, and delivery state. It must not present a single diode, transistor, photovoltaic, LED, or piezo-electric route as an average for this heterogeneous category.

Covered delivery states are completed device wafers sold as products, separated bare dies or cells, packaged discrete devices, declared photovoltaic cell assemblies or modules that remain within the classification reference, LED packages or arrays, and mounted piezo-electric crystal units. Purchased raw semiconductor wafers without completed active device structures, unmounted piezo-electric material, integrated circuits, complete luminaires, electronic equipment, and downstream systems are excluded. Parts not constituting the declared finished device, production equipment, and services are also excluded as reference products.

This is a manufacturing-gate PCR expressed on a mass reference. Count, active area, substrate area, rated electrical or optical performance, package or mount type, and tested grade remain mandatory supplementary quantities where applicable. Use-phase function is not made comparable by mass alone.

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.metal-products-machinery-and-equipment.radio-television-and-communication-equipment-and-apparatus.diodes-transistors-and-similar-semi-conductor-devices-photosensitive-semi-conductor-dev-f90ad4b6
classification_refsCPC 3.0: 47150, exact reviewed semantic scope
covered_productsDiscrete diodes, rectifiers, transistors, thyristors and similar devices; photosensitive semiconductor detectors and photovoltaic cells; declared PV cell assemblies or modules within the classification scope; LED dies, packages and arrays; mounted piezo-electric crystal units
excluded_productsRaw or device-free semiconductor wafers; unmounted piezo-electric material; electronic integrated circuits; complete lamps, luminaires, power converters, sensors or equipment containing the devices; generic electronic components; manufacturing equipment; parts that are not a finished in-scope device
representative_productNo single representative device is valid; each dataset declares one device family and one delivery state, or a documented production-weighted mix with family-level disaggregation
production_routeRoute-specific sequence from the declared incoming substrate, device wafer, die, cell or crystal blank through applicable active-structure fabrication, separation, packaging or mounting, final test, binning and release
market_stateConforming finished manufactured product at the declared processed-wafer, bare-die or cell, packaged-device, PV assembly or module, LED package or array, or mounted-crystal delivery gate

3. Reference Flow

FieldValue
WhatConforming finished in-scope device product at its declared delivery state
How much1 kg net product mass, excluding transport packaging unless packaging is inseparable from the marketed device
How wellReleased after the declared electrical, optical, photovoltaic or frequency-control test and binning criteria; rejects are not included in reference output
How long or cycleProduction from one representative reporting period or complete campaign, with dates, sites and exceptional periods disclosed
reference_flow_linkThe generic Tiangong product flow is used only with all required qualifiers; it does not authorize an unqualified category-average dataset
FieldValue
Reference amount1 kg
Reference product flowDiodes, transistors and similar semi-conductor devices, photosensitive semi-conductor devices, light emitting diodes, mounted piezo-electric crystals 2db29aee-6424-47c2-9951-6d33d99c611d
Reference flow propertyMass 93a60a56-a3c8-11da-a746-0800200b9a66
Reference unit groupUnits of mass 93a60a57-a4c8-11da-a746-0800200c9a66
Reference unitkg
Required qualifiersdevice_family; semiconductor_or_piezoelectric_material_system; delivery_state; processed_wafer_bare_die_cell_package_module_or_mount_definition; wafer_or_substrate_type_and_size_when_applicable; active_area_or_cell_area_when_applicable; die_count_or_device_count_per_reference_mass; package_mount_or_module_construction; electrical_optical_photovoltaic_or_frequency_grade; production_route; site_geography; reporting_period; conforming_output_mass; production_mix_rule

When constructing a foreground data package, the items listed in Required qualifiers must be declared in dataset metadata, process notes, reference flow comment, product description, or an equivalent data package field. Missing required qualifiers make the reference flow definition incomplete for that data package.

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
reference_massReference productMass 93a60a56-a3c8-11da-a746-0800200b9a66kgNormalize all inventory results to 1 kg of net conforming reference product at the declared delivery gate.
count_to_massItem-count production or test recordsMass plus countkg and itemConvert count records using measured lot mass divided by conforming item count, or a documented product-specific average mass from the same product and period; do not use a family-generic mass.
area_to_massWafer, cell, detector, LED or module area recordsMass plus areakg and m2Retain substrate or active area and convert to the mass reference using measured lot mass and matching processed area for the same route, device state and period.
performance_metadataElectrical, optical, photovoltaic and piezo-electric gradesMass plus declared performance quantitykg plus native test unitPreserve rated voltage, current, power, luminous or radiant output, responsivity, active area, frequency, or other applicable tested quantity as metadata; mass-normalized results alone are not suitable for functional comparisons.
net_product_massPackaged or mounted productsMasskgInclude the integral package, leads, mount, encapsulant, optics and integral module materials in net product mass; exclude removable shipping packaging and carriers returned to the supplier.

5. System Boundary

Boundary Abstraction

FieldValue
declared_starting_conditionReceipt of the route-specific semiconductor substrate or device wafer, purchased die or cell, or piezo-electric crystal blank or prepared resonator at the first foreground-controlled transformation
starting_condition_roleThe declared starting condition identifies which upstream material and device-forming stages require linked upstream datasets rather than being silently omitted
product_classification_scopeOne declared device family and delivery state within CPC 3.0 code 47150; any production-weighted mixed dataset preserves family and route shares
recursive_input_ruleAn in-scope purchased wafer, die, cell, LED, or mounted-device input is recorded as a same-category technosphere input with its own qualified upstream dataset; its burden is not recreated or treated as zero
upstream_dataset_requirementSupplier-specific or representative upstream datasets are required for substrates, wafers, dies, cells, crystals, package materials, process chemicals, gases, electricity and utilities outside foreground control
disclosureDeclare family, material system, wafer or substrate state, package or mount state, included sites and stages, outsourced stages, yield basis, allocation drivers, abatement coverage, cut-offs and data gaps
rule_idApplies toRulesource_ids
boundary_family_routeAll datasetsBuild the boundary for the declared device family and delivery state. Do not substitute the process map of another family or claim whole-category representativeness from one route.iec-63366-2025; us-doe-led-lca-2012; jrc-pv-footprint-2025; iec-60122-1-2017
boundary_semiconductor_fabricationSemiconductor, photosensitive, photovoltaic and LED routesInclude foreground-controlled active-structure formation and applicable wafer preparation, deposition or epitaxy, doping, masking, etching, cleaning, metallization, passivation and inspection. If these occur upstream, link qualified upstream datasets.us-epa-semiconductor-neshap; us-epa-subpart-i; us-doe-led-lca-2012
boundary_back_endSeparated, packaged, mounted or module productsInclude applicable dicing or separation, die attach, interconnection, electrode formation, encapsulation, optics, framing or module assembly, sealing, marking, test, binning and yield losses up to release.us-epa-semiconductor-neshap; us-doe-led-lca-2012; jrc-pv-footprint-2025; epson-crystal-device-process
boundary_emissions_and_treatmentAll included manufacturing stagesInclude process-gas and solvent releases, fluorinated GHG and N2O emissions where used, abatement operation and downtime, wastewater, hazardous and non-hazardous waste, recycling preparation and off-site treatment flows without netting them against inputs.us-epa-subpart-i; us-epa-electronics-effluent-guidelines
boundary_capital_and_downstreamDataset boundaryExclude manufacturing equipment, buildings, transport after the declared gate, use and end of life unless the study goal explicitly extends the system; disclose any included capital or downstream stages separately.iso-14044-2006; iec-63366-2025

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
wafer_or_device_fabricationActive-structure, wafer, die or cell fabricationconditionalInclude for foreground-controlled semiconductor, photosensitive, photovoltaic or LED structure fabrication; otherwise require a qualified upstream device-wafer, die or cell datasetForeground device formationkg conforming fabricated device wafer, die or cell, with substrate area and item count retained
device_or_module_assemblySeparation, package, LED array or PV assemblyconditionalInclude when separation, packaging, encapsulation, optics, mounting, module or panel assembly occurs before the declared gateForeground back-end assemblykg conforming assembled product before final release
piezoelectric_crystal_manufacture_and_mountingPiezo-electric crystal preparation and mountingconditionalInclude for mounted piezo-electric crystal products; require qualified upstream datasets for purchased synthetic crystal or prepared resonatorForeground crystal preparation and mount assemblykg conforming mounted crystal before final release
final_test_binning_releaseFinal test, binning and product releaserequiredRequired for every dataset; test content is family- and grade-specificForeground quality release and reference output1 kg net conforming reference product

Process: Active-structure, wafer, die or cell fabrication (wafer_or_device_fabrication)

Inputs

Product flows
Semiconductor substrate, device wafer or purchased precursor (fabrication_substrate_input)

Record each substrate, wafer, epitaxial wafer, semiconductor precursor and purchased active-device intermediate separately with its material system, dimensions, incoming state and upstream dataset.

  • Selected flow: Route-specific substrate, wafer or device intermediate; UUID unresolved until the concrete route is declared
  • Flow property / unit: Mass / kg; substrate area and item count retained
  • Amount rule: Foreground purchase and issue records reconciled to tool or lot tracking
  • Value mode: Foreground record (foreground_record)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg conforming output of this process
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material_and_bom_records
  • Sources: us-epa-semiconductor-neshap; us-doe-led-lca-2012; jrc-pv-footprint-2025
Process chemicals and gases (fabrication_chemicals_and_gases)

Record each distinct dopant, deposition or epitaxy precursor, etchant, cleaning chemical, photoresist, solvent, process gas, carrier gas and chamber-cleaning gas as an individual flow instance; do not collapse them into a generic chemical mass.

  • Selected flow: Route-specific chemical or gas; UUID unresolved until material identity is declared
  • Flow property / unit: Mass / kg or measured gas amount converted with documented conditions
  • Amount rule: Purchases, point-of-use delivery, cylinder or bulk-tank balance, and recipe records reconciled for the reporting period
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg conforming output of this process
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_process_material_and_gas_records
  • Sources: us-epa-subpart-i; us-epa-semiconductor-neshap
Electricity and manufacturing utilities (fabrication_energy_and_utilities)

Record electricity, process cooling, chilled water, clean dry air, nitrogen, vacuum and exhaust demand using metered tool or utility-system data and an explicit causal allocation driver.

  • Selected flow: Site-specific electricity and utility services; UUID unresolved until site supply is declared
  • Flow property / unit: Energy / kWh or MJ; utility-native quantities retained
  • Amount rule: Metered consumption or calculated share from monitored equipment and facility utility records
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg conforming output of this process
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_energy_utility_records
  • Sources: semi-s23-1021
Ultrapure and process water (fabrication_water_input)

Record incoming water by supplied quality and separately account for purification losses when purification is foreground-controlled.

  • Selected flow: Site-specific water supply; UUID unresolved until supply quality is declared
  • Flow property / unit: Volume / m3 and mass / kg where available
  • Amount rule: Metered fab, process-area or tool consumption allocated with the same route and period as output
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg conforming output of this process
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_energy_utility_records
  • Sources: semi-s23-1021; us-doe-led-lca-2012
Waste flows

No routine waste input is prescribed. Returned or reclaimed in-scope material entering this process is recorded as a product input with recycled-content status and upstream treatment disclosed.

Elementary flows

No elementary input is prescribed beyond resources represented by selected upstream product flows.

Outputs

Product flows
Fabricated device wafer, die or photovoltaic cell (fabricated_device_output)

Record the conforming output at the actual state leaving fabrication and retain wafer or substrate area, die or cell count, material system, technology, yield and tested grade.

  • Selected flow: Route- and state-specific fabricated device output; UUID unresolved until the concrete product is declared
  • Flow property / unit: Mass / kg; area and item count retained
  • Amount rule: Measured conforming output mass and reconciled lot disposition
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: process output before any downstream package or module assembly
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_yield_mass_and_disposition
  • Sources: iec-60747-1-2010; jrc-pv-footprint-2025
Waste flows
Fabrication scrap and spent process materials (fabrication_solid_and_liquid_waste)

Record rejected wafers, edge and kerf loss, spent slurries, resists, solvents, acids, bases, filters and other wastes as separate flows by composition and destination.

  • Selected flow: Waste-specific flow; UUID unresolved until composition and treatment are declared
  • Flow property / unit: Mass / kg
  • Amount rule: Weighed containers, manifests and inventory change reconciled to lot disposition
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg conforming output of this process
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_waste_and_wastewater_records
  • Sources: us-epa-electronics-effluent-guidelines
Fabrication wastewater (fabrication_wastewater)

Record wastewater by materially different stream before treatment, the treatment route, measured discharge and transferred residues; do not represent all streams as water alone.

  • Selected flow: Route-specific wastewater or treatment flow; UUID unresolved until composition and destination are declared
  • Flow property / unit: Volume / m3 and pollutant mass / kg
  • Amount rule: Flowmeter, sampling, treatment-log and discharge records for the reporting period
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg conforming output of this process
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_waste_and_wastewater_records
  • Sources: us-epa-electronics-effluent-guidelines
Elementary flows
Direct process air emissions (fabrication_direct_air_emissions)

Record each relevant emitted fluorinated GHG, N2O, acid gas, volatile organic compound and other measured or permitted release after abatement. Input gas consumption is not an emission factor by itself.

  • Selected flow: Substance-specific elementary flow; UUID unresolved until the emitted substance is declared
  • Flow property / unit: Mass / kg
  • Amount rule: Stack measurement or a documented jurisdictional calculation using collected gas use, utilization, by-product formation, abatement efficiency and downtime
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg conforming output of this process
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_direct_emission_records
  • Sources: us-epa-subpart-i; us-epa-semiconductor-neshap

Process: Separation, package, LED array or PV assembly (device_or_module_assembly)

Inputs

Product flows
Device wafer, die, cell or same-category component (assembly_device_input)

Record the incoming device state and link an upstream dataset with the same family, material system, route and delivery-state qualifiers.

  • Selected flow: Qualified route-specific device input; UUID resolved for the concrete device state before publication
  • Flow property / unit: Mass / kg; area and item count retained
  • Amount rule: Foreground receipts and issue records, including returned or rejected input
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg conforming assembled output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material_and_bom_records
  • Sources: us-doe-led-lca-2012; jrc-pv-footprint-2025
Package, mount, optical and module materials (assembly_material_inputs)

Record each leadframe, substrate, electrode, bond material, solder, encapsulant, housing, thermal interface, optical element, phosphor, glass, frame, backsheet, junction or interconnect material as an individual BOM flow when applicable.

  • Selected flow: Material-specific product flow; UUID unresolved until the construction is declared
  • Flow property / unit: Mass / kg
  • Amount rule: Product-specific BOM multiplied by released production, reconciled to receipts, issues, returns and scrap
  • Value mode: Calculated value (calculated_value)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg conforming assembled output
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_material_and_bom_records
  • Sources: us-doe-led-lca-2012; jrc-pv-footprint-2025
Assembly electricity and utilities (assembly_energy_and_utilities)

Record electricity, thermal energy, cleanroom and assembly utilities for separation, attach, interconnection, encapsulation, optics, lamination, framing, sealing and in-line tests.

  • Selected flow: Site-specific electricity and utility services; UUID unresolved until site supply is declared
  • Flow property / unit: Energy / kWh or MJ; utility-native quantities retained
  • Amount rule: Metered process consumption or a documented causal allocation from monitored equipment records
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg conforming assembled output
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_energy_utility_records
  • Sources: semi-s23-1021
Waste flows

No routine waste input is prescribed.

Elementary flows

No elementary input is prescribed beyond resources represented by selected upstream product flows.

Outputs

Product flows
Assembled device, LED array or PV assembly (assembled_device_output)

Record conforming output before final release with family, construction, package or module state, device count, net mass and applicable active area.

  • Selected flow: Route-specific assembled product; UUID unresolved until the concrete product is declared
  • Flow property / unit: Mass / kg; area and item count retained
  • Amount rule: Measured output mass and production disposition records
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: process output before final release
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_yield_mass_and_disposition
  • Sources: iec-60747-1-2010; us-doe-led-lca-2012; iec-62941-2019
Waste flows
Assembly rejects and material losses (assembly_rejects_and_scrap)

Record rejected dies, cells, packages, modules, frames, glass, encapsulants, metals and other losses separately by material and destination.

  • Selected flow: Waste-specific flow; UUID unresolved until composition and treatment are declared
  • Flow property / unit: Mass / kg and item count
  • Amount rule: Lot disposition, rework, scrap and waste-manifest records
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg conforming assembled output
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_yield_mass_and_disposition
  • Sources: jrc-pv-footprint-2025; us-doe-led-lca-2012
Elementary flows
Direct assembly releases (assembly_direct_releases)

Record measured or permitted solvent, soldering, curing, cleaning and other direct air or water releases by substance after controls.

  • Selected flow: Substance-specific elementary flow; UUID unresolved until substance identity is declared
  • Flow property / unit: Mass / kg
  • Amount rule: Monitoring, material balance or permitted calculation based on foreground records
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg conforming assembled output
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_direct_emission_records
  • Sources: us-epa-semiconductor-neshap; us-epa-electronics-effluent-guidelines

Process: Piezo-electric crystal preparation and mounting (piezoelectric_crystal_manufacture_and_mounting)

Inputs

Product flows
Piezo-electric crystal or prepared resonator input (piezoelectric_crystal_input)

Declare natural or synthetic origin, material composition, cut or orientation, blank or resonator state, dimensions and the upstream production boundary.

  • Selected flow: Product-specific piezo-electric crystal input; UUID unresolved until material and state are declared
  • Flow property / unit: Mass / kg and item count
  • Amount rule: Receipts, issue records and measured lot mass
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg conforming mounted crystal output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material_and_bom_records
  • Sources: epson-crystal-device-process; iec-60122-1-2017
Electrode, package and mounting materials (piezoelectric_mount_materials)

Record each electrode metal, adhesive, solder, lead, substrate, enclosure, sealing medium and cleaning material separately.

  • Selected flow: Material-specific product flow; UUID unresolved until mount construction is declared
  • Flow property / unit: Mass / kg
  • Amount rule: Product-specific BOM reconciled to purchases, issues and losses
  • Value mode: Calculated value (calculated_value)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg conforming mounted crystal output
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_material_and_bom_records
  • Sources: epson-crystal-device-process; iec-60122-1-2017
Crystal preparation and mounting energy (piezoelectric_energy_and_utilities)

Record electricity and utilities for cutting, shaping, polishing, cleaning, electrode formation, frequency adjustment, mounting, sealing and in-line test as applicable.

  • Selected flow: Site-specific electricity and utility services; UUID unresolved until site supply is declared
  • Flow property / unit: Energy / kWh or MJ; utility-native quantities retained
  • Amount rule: Metered equipment consumption or documented causal allocation
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg conforming mounted crystal output
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_energy_utility_records
  • Sources: semi-s23-1021; epson-crystal-device-process
Waste flows

No routine waste input is prescribed.

Elementary flows

No elementary input is prescribed beyond resources represented by selected upstream product flows.

Outputs

Product flows
Mounted piezo-electric crystal before final release (mounted_piezoelectric_output)

Record conforming units with material, cut, package or mount, nominal frequency or other controlled characteristic, item count and net mass.

  • Selected flow: Product-specific mounted piezo-electric crystal; UUID unresolved until the concrete product is declared
  • Flow property / unit: Mass / kg and item count
  • Amount rule: Measured conforming output mass and item count
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: process output before final release
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_yield_mass_and_disposition
  • Sources: iec-60122-1-2017
Waste flows
Crystal losses, rejects and spent materials (piezoelectric_waste)

Record cutting and polishing loss, off-spec resonators, electrode or package scrap, spent slurry, cleaning wastes and treatment destinations separately.

  • Selected flow: Waste-specific flow; UUID unresolved until composition and treatment are declared
  • Flow property / unit: Mass / kg and item count where applicable
  • Amount rule: Lot disposition, mass balance and waste-manifest records
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg conforming mounted crystal output
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_waste_and_wastewater_records
  • Sources: epson-crystal-device-process
Elementary flows
Direct crystal-process releases (piezoelectric_direct_releases)

Record substance-specific releases from etching, cleaning, electrode formation, joining and sealing when they cross the environmental boundary.

  • Selected flow: Substance-specific elementary flow; UUID unresolved until substance identity is declared
  • Flow property / unit: Mass / kg
  • Amount rule: Monitoring or foreground material balance after controls
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg conforming mounted crystal output
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_direct_emission_records
  • Sources: us-epa-electronics-effluent-guidelines

Process: Final test, binning and product release (final_test_binning_release)

Inputs

Product flows
Product awaiting final release (pre_release_product_input)

Record the applicable fabricated, assembled or mounted product input with its route and state unchanged.

  • Selected flow: Qualified pre-release product state; UUID resolved for the concrete dataset when available
  • Flow property / unit: Mass / kg and item count
  • Amount rule: Measured mass and item count entering final test
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg released reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_yield_mass_and_disposition
  • Sources: iec-60747-1-2010; iec-60122-1-2017; iec-62941-2019
Test electricity and consumables (final_test_inputs)

Record test-system electricity, thermal conditioning, burn-in where applied, carriers consumed, and other non-reusable consumables.

  • Selected flow: Site-specific energy and material flows; UUID unresolved until the test route is declared
  • Flow property / unit: Energy / kWh or MJ and material mass / kg
  • Amount rule: Metered test-cell consumption and consumed-material records allocated by tested item-hours or another causal driver
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per 1 kg released reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_test_and_grade_records
  • Sources: iec-60747-1-2010; iec-60122-1-2017; iec-62941-2019
Waste flows

No routine waste input is prescribed.

Elementary flows

No elementary input is prescribed beyond resources represented by selected upstream product flows.

Outputs

Product flows
Released reference product (reference_product_output)

The output is exactly the qualified Tiangong reference flow with the dataset-specific family, route, state, construction, grade, count or area, site and period qualifiers.

  • Selected flow: Diodes, transistors and similar semi-conductor devices, photosensitive semi-conductor devices, light emitting diodes, mounted piezo-electric crystals 2db29aee-6424-47c2-9951-6d33d99c611d
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: exactly 1 kg net conforming released product after normalization
  • Value mode: Fixed value (fixed_value)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: 1 kg reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Identity reference (identity_reference)
  • Sources:
Waste flows
Final-test rejects and downgraded product (final_test_rejects)

Record rejected, downgraded, reworked and scrapped items separately. A downgraded product is a co-product only when it is sold for a documented function and leaves as a distinct product flow.

  • Selected flow: Disposition-specific waste or product flow; UUID unresolved until disposition is declared
  • Flow property / unit: Mass / kg and item count
  • Amount rule: Test-bin and disposition records reconciled to pre-release input and released output
  • Value mode: Calculated value (calculated_value)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg released reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_test_and_grade_records
  • Sources: iec-60747-1-2010; iec-60122-1-2017; iec-62941-2019
Elementary flows

No generic elementary output is prescribed. Record direct test or burn-in releases if they occur.

7. Allocation and Co-product Handling

rule_idApplies toRulesource_ids
allocation_avoidMulti-product facilities and shared linesPrefer process subdivision, direct metering and product-route records so allocation is avoided wherever practicable.iso-14044-2006; semi-s23-1021
allocation_causal_driverShared tools, cleanrooms and utilitiesAllocate unavoidable shared consumption using a documented causal driver such as recipe tool-time, wafer or substrate area by process step, chamber cycles, processed item-hours, metered load, exhaust demand or cooling load. Production mass or revenue may not be used without demonstrating why it reflects the physical relationship.iso-14044-2006; semi-s23-1021; us-epa-subpart-i
allocation_yield_and_reworkRejects, rework and downgraded binsAssign burdens of ordinary yield loss and rework to conforming output. Treat a downgraded bin as a co-product only when it has a documented market function and separate flow; disclose the chosen physical or economic allocation and test it in sensitivity analysis.iso-14044-2006
allocation_recyclingRecovered materials and returned carriersReport material recovery, recycled content and any substitution credit separately. Apply one disclosed recycling allocation convention consistently and prevent double counting between the supplying and receiving systems.iso-14044-2006; iec-63366-2025

8. Foreground Data Collection, Calculation, and Quality Rules

No category-wide numerical default is authorized. The device families, material systems, wafer sizes, package states, yields and production technologies are too heterogeneous for a single credible range. All important amounts therefore require foreground records or a reviewed family- and route-specific external dataset; any future reasoned_estimate is temporary, replaceable and usable only as a QA screen.

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_product_identity_and_massfinal_test_binning_releaseReference product identity and massProduct master, lot release and scale recordfamily; material_system; delivery_state; construction; grade; lot_id; item_count; net_mass; area; site; datesControlled master-data export joined to calibrated scale and release recordskg; item; m2 as applicableEach released lotRepresentative reporting period or complete campaignEvery included release siteSum net conforming mass by qualified product, then preserve family and route sharesCalibration record; product specification; test release; traceable lot reconciliation
cp_material_and_bom_recordswafer_or_device_fabrication; device_or_module_assembly; piezoelectric_crystal_manufacture_and_mountingMaterial inputsBOM, purchase, warehouse issue and return recordsmaterial_id; composition; supplier; upstream_state; quantity; unit; lot; issue; return; inventory_change; recycled_contentReconcile product-specific BOM to receipts, issues, returns and inventory changekg; item; m2Each lot with monthly reconciliationSame period as outputEvery included process and outsourced supplier stageMaterial used equals opening inventory plus receipts minus closing inventory and documented returnsApproved BOM revision; supplier certificate; inventory reconciliation
cp_process_material_and_gas_recordswafer_or_device_fabricationProcess chemicals and gasesBulk-tank, cylinder, point-of-use and recipe recordssubstance; purity; mass_or_volume; conditions; tool; recipe; lot; return; residual; abatement_linkReconcile purchases and inventory change to point-of-use or recipe consumptionkg; m3 with temperature and pressureContinuous or each container and recipeSame period as outputEach fab and process typeSubstance-specific use allocated by direct measure or documented recipe driverMeter calibration; container balance; recipe audit; uncertainty statement
cp_energy_utility_recordsAll applicable process idsElectricity, water and utilitiesMeter, equipment-state and facility utility logmeter_id; utility; quantity; unit; timestamp; tool_state; process; allocation_driver; calibrationPrefer submetering; otherwise allocate monitored facility totals using causal engineering driverskWh; MJ; m3; kg; utility-native unitContinuous or batch-resolvedSame period as output, including idle and maintenanceEach included site and shared utility systemSum measured use and allocate only the documented shared portion to conforming outputMeter calibration; coverage report; reconciliation to facility bill; allocation sensitivity
cp_yield_mass_and_dispositionAll applicable process idsProduct yield, rework and wasteManufacturing execution, test-bin, scale and waste recordsinput_lot; output_lot; input_mass; output_mass; item_count; area; pass; rework; downgrade; scrap; destinationReconcile lot genealogy and all dispositionskg; item; m2Each lotSame period as outputEach included processPreserve stage yield and assign normal loss to conforming output; do not hide rework loopsClosed lot balance; disposition approval; scale calibration
cp_direct_emission_recordsAll applicable process idsDirect air and water releasesStack test, continuous monitoring, gas-use, abatement and permit recordssubstance; input_use; by_product; utilization; abatement_efficiency; downtime; measured_release; method; uncertaintyUse direct monitoring where available or a documented applicable regulatory method based on collected activity datakg per substanceContinuous, test campaign or regulatory reporting intervalSame period as outputEach emitting fab, stack and treatment systemSum substance-specific controlled releases and normalize to conforming outputMethod report; calibration; abatement uptime; permit or regulatory reconciliation
cp_waste_and_wastewater_recordsAll applicable process idsWaste and wastewaterFlowmeter, sample, waste manifest and treatment logstream; volume; pollutant_concentration; waste_mass; composition; hazard_class; treatment; destination; recoveryMeasure separate streams and reconcile transferred residues and dischargem3; kgContinuous, batch or shipmentSame period as outputEach included site and treatment routeSum by composition and destination before normalizationLaboratory QA; manifest; flowmeter calibration; treatment acceptance record
cp_test_and_grade_recordsfinal_test_binning_releaseFunctional test, binning and releaseTest-system and quality recordsdevice_id_or_lot; test_method; grade; performance_value; unit; pass; fail; downgrade; test_time; burn_in; energyExport traceable results from controlled test systems and join to product dispositionNative performance unit; item; kg; kWhEach tested lot or itemSame period as outputEvery included release siteAggregate only within identical family, state, construction and grade; retain distributions when materialTest calibration; applicable product standard; release authorization; exception log

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
calc_mass_normalizationEvery inventory amountnormalized amount = period amount divided by period net conforming reference-product mass in kgPeriod amount; net conforming mass from cp_product_identity_and_massAmount per 1 kg reference productiso-14044-2006
calc_count_area_conversionCount- or area-based recordsUse matching lot mass divided by count or processed area; keep the original count or area and prohibit cross-family conversion factorsLot mass; item count; processed area; route and stateProduct-specific count-to-mass or area-to-mass factorus-epa-subpart-i; us-doe-led-lca-2012; jrc-pv-footprint-2025
calc_stage_yieldEach manufacturing stagestage yield = conforming output quantity divided by total input quantity on a consistent mass, item or area basis; separately report rework and downgradeInput, conforming output, rework, downgrade and scrap recordsStage yield and reconciled dispositionjrc-pv-footprint-2025; iec-62941-2019
calc_shared_utilityShared energy and utilitiesallocated amount = measured shared amount multiplied by the documented causal-driver share; report unallocated and excluded portionsMetered total; driver values; meter coverageAllocated utility amount and allocation sensitivitysemi-s23-1021; us-epa-subpart-i
calc_direct_emissionsProcess gases and controlled releasesApply direct measurement or the selected applicable method to collected gas use, utilization, by-product formation, abatement efficiency and downtime; never equate purchased gas with emitted gas without justificationGas and monitoring records from cp_direct_emission_recordsSubstance-specific direct emissionus-epa-subpart-i
calc_mass_reconciliationEach process and reporting periodinput mass plus opening inventory = product mass plus waste mass plus measured releases plus closing inventory, with non-mass service flows excluded and the residual reportedMaterial, product, waste, release and inventory recordsMass-balance residual and explained exceptionsiso-14044-2006

Data Quality Requirements

requirement_idApplies toRequirementEvidence
dq_identityReference productAll required qualifiers match the product master, test grade and delivery state; a generic flow name alone is insufficientProduct specification, master-data snapshot and release record
dq_family_routeProcess coverageEvidence demonstrates that included and outsourced stages match the declared family, material system, technology, wafer or crystal state, package or mount, and reporting periodRoute map, supplier declarations, process recipes and lot genealogy
dq_temporalForeground activity dataUse a representative reporting period that captures normal production, idle, maintenance, abatement downtime, rework and yield variation; justify and flag pilot or short-campaign dataProduction calendar, meter coverage and exception log
dq_completenessInventoryNo hazardous, fluorinated-gas, water, waste, high-mass, high-energy or yield-significant flow is excluded by a mass cut-off alone; disclose all cut-offs and missing substancesCompleteness checklist, material balance and regulatory records
dq_source_matchUpstream datasetsTechnology, geography, time, material purity and delivery state of upstream datasets are stated and mismatches are assessedDataset metadata and representativeness assessment
dq_allocationShared systems and co-productsAllocation driver, measurement coverage, excluded load and sensitivity are reproducible from retained recordsMeter map, engineering model, driver data and sensitivity result
dq_uncertaintyCalculated and modelled valuesReport measurement uncertainty, estimation method and unresolved data gaps; provisional estimates may not be presented as observed valuesCalibration certificates, method report and uncertainty register

9. Validation Rules

rule_idApplies toRulesource_ids
validate_reference_identityReference flowThe product UUID, Mass UUID, Units of mass UUID and kg unit exactly match section 3.
validate_required_qualifiersDataset identityFail when device family, material system, delivery state, construction, grade, route, site, period, mass and applicable count or area qualifiers are missing.iec-60747-1-2010; iec-60122-1-2017; iec-62941-2019
validate_no_single_family_proxyRepresentativeness claimFail any claim to represent all of CPC 47150 when evidence covers only one diode, transistor, PV, LED, photosensitive or piezo-electric family. A mixed dataset must disclose production-weighted family and route shares and retain disaggregated inventory.iec-63366-2025; us-doe-led-lca-2012; jrc-pv-footprint-2025
validate_route_and_stateProcess mapIncluded stages, purchased intermediates and upstream datasets must reconcile with the declared incoming state and marketed delivery state; no wafer, die, package, module or mount stage may be double counted or silently omitted.us-epa-semiconductor-neshap; us-doe-led-lca-2012; epson-crystal-device-process
validate_process_coverageManufacturing boundaryAt least one family-specific production route plus final_test_binning_release is present; each conditional stage is explicitly included, outsourced with an upstream dataset, or not applicable with reason.iec-63366-2025
validate_yield_and_mass_balanceEach processInput, output, rework, downgrade, scrap, waste, release and inventory-change records reconcile; unexplained residuals and inconsistent mass, count or area yield bases are findings.iso-14044-2006; iec-62941-2019
validate_energy_utility_allocationShared energy and utilitiesMeter coverage and causal allocation drivers are disclosed and reproduce the normalized amount; revenue-only or unsubstantiated mass allocation is a finding.semi-s23-1021; us-epa-subpart-i
validate_direct_emissionsFabs and emitting assembly stagesWhen fluorinated gases, N2O, solvents, acid gases or other controlled substances are used, substance-specific emissions, abatement method and downtime are present or the check is explicitly inconclusive.us-epa-subpart-i; us-epa-semiconductor-neshap
validate_wastewater_and_wasteWet and material-removal processesWastewater and waste are distinguished by stream, composition and treatment destination; absence of evidence for an applicable stream is a finding.us-epa-electronics-effluent-guidelines
validate_foreground_evidenceImportant amountsImportant amounts are foreground records or calculations from collection. A reasoned estimate, if introduced, is labelled temporary and replaceable and is not used as a conformance limit or whole-family default.iso-14044-2006; iec-63366-2025
validate_recursive_inputsSame-category intermediatesPurchased in-scope wafers, dies, cells or devices have qualified upstream datasets and are not assigned zero burden or expanded recursively.iec-63366-2025

10. Published Dataset Profile

FieldValue
dataset_roleForeground manufacturing data package for one qualified CPC 47150 device family, route and delivery state
downstream_usesecondary_dataset; background_dataset after methodology review and publication
allowed_useProduct- and route-specific supply-chain modelling when reference-flow qualifiers, included stages, upstream datasets and data quality match the study
excluded_useUnqualified whole-leaf average; substitution among PV, LED, power-electronic, photosensitive, discrete-semiconductor and piezo-electric families; functional comparison using kg alone; use-phase performance claim; proxy for integrated circuits, luminaires or complete equipment
required_metadataAll reference-flow qualifiers; site and period; technology and route; wafer, die, cell, package, module or mount state; BOM revision; yield basis; count and area conversions; included and outsourced stages; upstream dataset references; allocation and recycling methods; abatement and treatment coverage
required_quality_disclosureForeground measurement coverage; calibration; temporal, geographical and technological representativeness; meter and mass-balance reconciliation; family and route shares for mixes; cut-offs; uncertainty; reasoned estimates; missing UUIDs or substances; data gaps
update_triggerChange in device family, material system, wafer or substrate size, active structure, package or module construction, major process route, site electricity, yield, abatement, allocation driver, product grade, or reporting period that materially affects the inventory

11. Data Sources

Source idTypeReferenceUsed for
un-cpc-47150official_guidanceUnited Nations Statistics Division, CPC classification detail for code 47150, https://unstats.un.org/unsd/classifications/Econ/Structure/Detail/EN/1073/47150 (accessed 2026-08-09)Classification scope identity
iso-14044-2006standardISO 14044:2006, Environmental management — Life cycle assessment — Requirements and guidelines, https://www.iso.org/standard/38498.html (confirmed current in 2022; accessed 2026-08-09)LCI, allocation, consistency, completeness and interpretation rules
iec-63366-2025standardIEC 63366:2025, Product category rules for life cycle assessment of electrical and electronic products and systems, https://webstore.iec.ch/en/publication/67691 (accessed 2026-08-09)Horizontal EEPS PCR and need for product-specific complementary specifications
iec-60747-1-2010standardIEC 60747-1:2006+A1:2010, Semiconductor devices — Part 1: General, https://webstore.iec.ch/en/publication/3244 (accessed 2026-08-09)Discrete semiconductor identity, ratings, characteristics, measurement and release evidence
iec-60122-1-2017standardIEC 60122-1:2002+A1:2017, Quartz crystal units of assessed quality — Part 1: Generic specification, https://webstore.iec.ch/en/publication/62199 (accessed 2026-08-09)Mounted quartz crystal identity, qualification and test evidence
iec-62941-2019standardIEC 62941:2019, Terrestrial photovoltaic modules — Quality system for PV module manufacturing, https://webstore.iec.ch/en/publication/61932 (accessed 2026-08-09)PV construction, material and process control, test and manufacturing consistency
us-epa-semiconductor-neshapofficial_guidanceU.S. EPA, Semiconductor Manufacturing National Emission Standards for Hazardous Air Pollutants, https://www.epa.gov/stationary-sources-air-pollution/semiconductor-manufacturing-national-emission-standards-hazardous (accessed 2026-08-09)Semiconductor boundary from crystal growth through wafer fabrication, test and assembly; relevant direct releases
us-epa-subpart-iofficial_guidanceU.S. EPA, Subpart I Information Sheet — Electronics Manufacturing, https://www.epa.gov/ghgreporting/subpart-i-information-sheet (accessed 2026-08-09)Fluorinated GHG, N2O, HTF, abatement, wafer diameter, substrate area and fab-level monitoring rules
us-epa-electronics-effluent-guidelinesofficial_guidanceU.S. EPA, Electrical and Electronic Components Effluent Guidelines Documents, https://www.epa.gov/eg/electrical-and-electronic-components-effluent-guidelines-documents (accessed 2026-08-09)Wastewater stream, pollutant and treatment records
semi-s23-1021standardSEMI S23-1021, Guide for Energy, Utilities, and Materials Use Efficiency of Semiconductor Manufacturing Equipment; official revision notice, https://www.semi.org/en/standards-watch-2021Dec/revisions-to-semi-s23-published (accessed 2026-08-09)Tool and facility energy, cooling-water, utility and material measurement and allocation drivers
us-doe-led-lca-2012official_guidanceU.S. Department of Energy, Life-Cycle Assessment of Energy and Environmental Impacts of LED Lighting Products, Part 2: LED Manufacturing and Performance, https://www.energy.gov/documents/2012ledlca-pt2pdf-0 (2012; accessed 2026-08-09)LED substrate, epitaxy, die fabrication, packaging, test and binning decomposition; heterogeneity and data-gap treatment
jrc-pv-footprint-2025official_guidanceEuropean Commission Joint Research Centre, Harmonised rules for the calculation of the carbon footprint of photovoltaic modules in the context of the EU Ecodesign Directive, JRC141275, DOI 10.2760/4062978, https://publications.jrc.ec.europa.eu/repository/handle/JRC141275 (2025; accessed 2026-08-09)PV technology and delivery-state separation, company-specific BOM, energy, yield and data-quality requirements
epson-crystal-device-processextension_guidanceSeiko Epson Corporation, Crystal devices: roles, manufacturing process and applications, https://www.epsondevice.com/crystal/ja/techinfo/column/general/crystal-device.html (accessed 2026-08-09)Synthetic quartz and crystal-device manufacturing-route decomposition

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 5
Rule IDApplies toRuleSource IDs
boundary_family_routeAll datasetsBuild the boundary for the declared device family and delivery state. Do not substitute the process map of another family or claim whole-category representativeness from one route.iec-63366-2025, us-doe-led-lca-2012, jrc-pv-footprint-2025, iec-60122-1-2017
boundary_semiconductor_fabricationSemiconductor, photosensitive, photovoltaic and LED routesInclude foreground-controlled active-structure formation and applicable wafer preparation, deposition or epitaxy, doping, masking, etching, cleaning, metallization, passivation and inspection. If these occur upstream, link qualified upstream datasets.us-epa-semiconductor-neshap, us-epa-subpart-i, us-doe-led-lca-2012
boundary_back_endSeparated, packaged, mounted or module productsInclude applicable dicing or separation, die attach, interconnection, electrode formation, encapsulation, optics, framing or module assembly, sealing, marking, test, binning and yield losses up to release.us-epa-semiconductor-neshap, us-doe-led-lca-2012, jrc-pv-footprint-2025, epson-crystal-device-process
boundary_emissions_and_treatmentAll included manufacturing stagesInclude process-gas and solvent releases, fluorinated GHG and N2O emissions where used, abatement operation and downtime, wastewater, hazardous and non-hazardous waste, recycling preparation and off-site treatment flows without netting them against inputs.us-epa-subpart-i, us-epa-electronics-effluent-guidelines
boundary_capital_and_downstreamDataset boundaryExclude manufacturing equipment, buildings, transport after the declared gate, use and end of life unless the study goal explicitly extends the system; disclose any included capital or downstream stages separately.iso-14044-2006, iec-63366-2025
Allocation rules · 4
Rule IDApplies toRuleSource IDs
allocation_avoidMulti-product facilities and shared linesPrefer process subdivision, direct metering and product-route records so allocation is avoided wherever practicable.iso-14044-2006, semi-s23-1021
allocation_causal_driverShared tools, cleanrooms and utilitiesAllocate unavoidable shared consumption using a documented causal driver such as recipe tool-time, wafer or substrate area by process step, chamber cycles, processed item-hours, metered load, exhaust demand or cooling load. Production mass or revenue may not be used without demonstrating why it reflects the physical relationship.iso-14044-2006, semi-s23-1021, us-epa-subpart-i
allocation_yield_and_reworkRejects, rework and downgraded binsAssign burdens of ordinary yield loss and rework to conforming output. Treat a downgraded bin as a co-product only when it has a documented market function and separate flow; disclose the chosen physical or economic allocation and test it in sensitivity analysis.iso-14044-2006
allocation_recyclingRecovered materials and returned carriersReport material recovery, recycled content and any substitution credit separately. Apply one disclosed recycling allocation convention consistently and prevent double counting between the supplying and receiving systems.iso-14044-2006, iec-63366-2025
Validation rules · 11
Rule IDApplies toRuleSource IDs
validate_reference_identityReference flowThe product UUID, Mass UUID, Units of mass UUID and kg unit exactly match section 3.
validate_required_qualifiersDataset identityFail when device family, material system, delivery state, construction, grade, route, site, period, mass and applicable count or area qualifiers are missing.iec-60747-1-2010, iec-60122-1-2017, iec-62941-2019
validate_no_single_family_proxyRepresentativeness claimFail any claim to represent all of CPC 47150 when evidence covers only one diode, transistor, PV, LED, photosensitive or piezo-electric family. A mixed dataset must disclose production-weighted family and route shares and retain disaggregated inventory.iec-63366-2025, us-doe-led-lca-2012, jrc-pv-footprint-2025
validate_route_and_stateProcess mapIncluded stages, purchased intermediates and upstream datasets must reconcile with the declared incoming state and marketed delivery state; no wafer, die, package, module or mount stage may be double counted or silently omitted.us-epa-semiconductor-neshap, us-doe-led-lca-2012, epson-crystal-device-process
validate_process_coverageManufacturing boundaryAt least one family-specific production route plus final_test_binning_release is present; each conditional stage is explicitly included, outsourced with an upstream dataset, or not applicable with reason.iec-63366-2025
validate_yield_and_mass_balanceEach processInput, output, rework, downgrade, scrap, waste, release and inventory-change records reconcile; unexplained residuals and inconsistent mass, count or area yield bases are findings.iso-14044-2006, iec-62941-2019
validate_energy_utility_allocationShared energy and utilitiesMeter coverage and causal allocation drivers are disclosed and reproduce the normalized amount; revenue-only or unsubstantiated mass allocation is a finding.semi-s23-1021, us-epa-subpart-i
validate_direct_emissionsFabs and emitting assembly stagesWhen fluorinated gases, N2O, solvents, acid gases or other controlled substances are used, substance-specific emissions, abatement method and downtime are present or the check is explicitly inconclusive.us-epa-subpart-i, us-epa-semiconductor-neshap
validate_wastewater_and_wasteWet and material-removal processesWastewater and waste are distinguished by stream, composition and treatment destination; absence of evidence for an applicable stream is a finding.us-epa-electronics-effluent-guidelines
validate_foreground_evidenceImportant amountsImportant amounts are foreground records or calculations from collection. A reasoned estimate, if introduced, is labelled temporary and replaceable and is not used as a conformance limit or whole-family default.iso-14044-2006, iec-63366-2025
validate_recursive_inputsSame-category intermediatesPurchased in-scope wafers, dies, cells or devices have qualified upstream datasets and are not assigned zero burden or expanded recursively.iec-63366-2025
Processes and inputs/outputs · 4
Process IDProcess nameInput flowsOutput flows
wafer_or_device_fabricationActive-structure, wafer, die or cell fabrication44
device_or_module_assemblySeparation, package, LED array or PV assembly33
piezoelectric_crystal_manufacture_and_mountingPiezo-electric crystal preparation and mounting33
final_test_binning_releaseFinal test, binning and product release22

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page

1. Scope and Applicability2. Product Category Identity3. Reference Flow4. Measurement and Unit Rules5. System BoundaryBoundary Abstraction6. Process Inventory StructureProcess MapProcess: Active-structure, wafer, die or cell fabrication (wafer_or_device_fabrication)InputsProduct flowsSemiconductor substrate, device wafer or purchased precursor (fabrication_substrate_input)Process chemicals and gases (fabrication_chemicals_and_gases)Electricity and manufacturing utilities (fabrication_energy_and_utilities)Ultrapure and process water (fabrication_water_input)Waste flowsElementary flowsOutputsProduct flowsFabricated device wafer, die or photovoltaic cell (fabricated_device_output)Waste flowsFabrication scrap and spent process materials (fabrication_solid_and_liquid_waste)Fabrication wastewater (fabrication_wastewater)Elementary flowsDirect process air emissions (fabrication_direct_air_emissions)Process: Separation, package, LED array or PV assembly (device_or_module_assembly)InputsProduct flowsDevice wafer, die, cell or same-category component (assembly_device_input)Package, mount, optical and module materials (assembly_material_inputs)Assembly electricity and utilities (assembly_energy_and_utilities)Waste flowsElementary flowsOutputsProduct flowsAssembled device, LED array or PV assembly (assembled_device_output)Waste flowsAssembly rejects and material losses (assembly_rejects_and_scrap)Elementary flowsDirect assembly releases (assembly_direct_releases)Process: Piezo-electric crystal preparation and mounting (piezoelectric_crystal_manufacture_and_mounting)InputsProduct flowsPiezo-electric crystal or prepared resonator input (piezoelectric_crystal_input)Electrode, package and mounting materials (piezoelectric_mount_materials)Crystal preparation and mounting energy (piezoelectric_energy_and_utilities)Waste flowsElementary flowsOutputsProduct flowsMounted piezo-electric crystal before final release (mounted_piezoelectric_output)Waste flowsCrystal losses, rejects and spent materials (piezoelectric_waste)Elementary flowsDirect crystal-process releases (piezoelectric_direct_releases)Process: Final test, binning and product release (final_test_binning_release)InputsProduct flowsProduct awaiting final release (pre_release_product_input)Test electricity and consumables (final_test_inputs)Waste flowsElementary flowsOutputsProduct flowsReleased reference product (reference_product_output)Waste flowsFinal-test rejects and downgraded product (final_test_rejects)Elementary flows7. Allocation and Co-product Handling8. Foreground Data Collection, Calculation, and Quality RulesData Collection ProtocolsCalculation RulesData Quality Requirements9. Validation Rules10. Published Dataset Profile11. Data Sources