TianGong PCR产品类别规则

Other units of automatic data processing machines

Other units of automatic data processing machines: This PCR applies to separately presented automatic data processing units within the reviewed semantic boundary of CPC…

Lifecycle status
Candidate
Content maturity
Authored methodology
Current version
No published version
Readiness
Review required
Last updated

Methodology and translation states come from the source record; publishing this website does not change their review status.

Content languages

zh-CN · Aligned
Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:45289 · exact

Source

1. Scope and Applicability

This PCR applies to separately presented automatic data processing units within the reviewed semantic boundary of CPC 3.0 subclass 45289: arithmetic units; accelerators other than graphics accelerators; print processors; control and adaptor units; disk-to-tape or tape-to-disk converters; machines that decode data and present the result in clear form; machines that introduce fixed programs into integrated circuits; and machines that transcribe data onto media in coded form.

Every foreground data package shall select one equipment family from that list and describe the unit's data-processing function. A product that cannot be assigned unambiguously to one listed family, or that combines functions whose principal identity may fall in another subclass, requires manual_review before this PCR is used.

The default dataset boundary is production of a finished unit at the manufacturing gate. It covers attributable parts and subassemblies, PCBA and final assembly, configuration and functional testing, warehousing, and packaging. It does not by default include outbound delivery, use-stage electricity or data-centre overhead, maintenance, or end-of-life; any extension shall be separately modelled and disclosed.

Servers and other complete automatic data processing machines; systems presented as complete systems; fixed or removable storage units; input or output peripherals; video, graphics, sound, or network expansion cards; integrated circuits; general network communications equipment; and generic parts or accessories that do not themselves perform the listed data-processing functions are excluded.

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.metal-products-machinery-and-equipment.office-accounting-and-computing-machinery.other-units-of-automatic-data-processing-machines
classification_refsCPC 3.0: 45289, Other units of automatic data processing machines
covered_productsSeparately presented arithmetic units; non-graphics accelerators; print processors; control and adaptor units; disk-to-tape or tape-to-disk converters; clear-form data decoders; fixed-program introducing machines; coded-media transcribing machines
excluded_productsServers and other complete computers; ADP systems; fixed or removable storage units; input or output peripherals; graphics, video, sound, or network cards; integrated circuits; network communications equipment; passive parts and accessories
representative_productOne declared CPC 45289 equipment-family unit with a complete configuration record, normalized by finished net mass
production_routeSupplier parts and subassemblies; kitting; PCBA or module integration; final assembly; firmware or fixed-program loading where applicable; functional and power testing; warehousing; packaging at plant
market_stateFinished, tested unit at manufacturing gate; packaging is inventoried separately and the delivered or unpackaged state is declared

3. Reference Flow

FieldValue
WhatProduction of a separately presented CPC 45289 automatic data processing unit that performs the declared equipment-family function
How much1 kg finished net product at the manufacturing gate
How wellConforming to the declared function, native capacity metric, tested configuration, interfaces, power profile, thermal design, and acceptance criteria
How long or cycleOne manufacturing lot normalized to 1 kg accepted product; if a use-stage extension is modelled, operating lifetime and mode-time profile are declared separately
reference_flow_linkAll production inputs, wastes, and releases are normalized to accepted net product mass; item counts are converted using measured net mass per accepted unit
FieldValue
Reference amount1 kg
Reference product flowOther units of automatic data processing machines b3854d4e-54f5-4fad-9457-2f899c4a1653
Reference flow propertyMass 93a60a56-a3c8-11da-a746-0800200b9a66
Reference unit groupUnits of mass 93a60a57-a4c8-11da-a746-0800200c9a66
Reference unitkg
Required qualifiersequipment family; primary data-processing function; native functional or capacity rating and test method; rated / active / idle / sleep / off power states where supported; chassis or enclosure form and rack or board form factor; PCB and subassembly configuration; integrated storage type and capacity if incidental; interface types and counts; integrated cooling type and coolant charge if any; power-supply configuration; firmware or fixed-program state; net unit mass; packaging inclusion; delivery boundary; manufacturing geography; reporting period; lot and yield basis

When constructing a foreground data package, the items listed in Required qualifiers must be declared in dataset metadata, process notes, reference flow comment, product description, or an equivalent data package field. Missing required qualifiers make the reference flow definition incomplete for that data package.

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
reference_massreference productMass 93a60a56-a3c8-11da-a746-0800200b9a66kgMeasure accepted net product mass without transport packaging. If a packaged reference state is required, report product and packaging masses separately and keep the reference amount tied to net product mass.
count_to_massitem-count production recordsMass 93a60a56-a3c8-11da-a746-0800200b9a66kgConvert accepted and rejected item counts with measured configuration-specific mass per item from the same reporting period; do not use nominal catalogue mass when measured lot mass is available.
functional_capacityproduct identity and test resultsFamily-specific native capacitydeclared native unitState the equipment-family function and its native rating or throughput test. Do not aggregate different equipment families by an invented common capacity factor; route a non-equivalent or ambiguous unit to manual_review.
power_and_energyproduction tests and any use-stage extensionEnergy and powerkWh and WRecord measured power by supported operating state, workload or capacity setting, test method, and duration. Calculate energy from state-specific power and time; do not fold data-centre cooling, UPS, or other site overhead into device electricity without a separately declared allocation.
bom_mass_balanceparts, subassemblies, finished product, rejects, and scrapMass 93a60a56-a3c8-11da-a746-0800200b9a66kgReconcile incoming attributable component mass with accepted product, packaging handled separately, rejects, recoverable scrap, and other wastes over the same lot and reporting period.
delivery_serviceconditional outbound deliveryTransport service and masstonne-km and kgRecord mode, origin, destination, distance, load factor, and shipped mass separately. Delivery is outside the default factory-gate reference flow and shall not be hidden in product mass or manufacturing energy.

5. System Boundary

Boundary Abstraction

FieldValue
declared_starting_conditionPurchased parts, PCBAs, modules, enclosure and mechanical parts, cables and connectors, power and integrated cooling parts, incidental storage where applicable, auxiliary materials, and packaging arrive at the manufacturing or integration site with supplier dataset identities declared.
starting_condition_roleUpstream dataset boundary for supplier-produced parts and subassemblies; foreground collection begins with receipt, kitting, in-house assembly, test, warehousing, and packaging activities.
product_classification_scopeOnly separately presented units within the reviewed CPC 45289 equipment families; the equipment family and principal function are mandatory identity fields.
recursive_input_ruleA purchased item already meeting the same CPC 45289 product identity is recorded as an upstream product input with its supplier dataset and configuration; its production is not recreated inside the receiving foreground process.
upstream_dataset_requirementUse technology-, geography-, and time-representative datasets for PCBAs, integrated circuits and other electronic parts, enclosure and mechanical parts, interfaces and cabling, power components, integrated cooling components and coolant, incidental storage, auxiliary materials, packaging, electricity, and waste treatment.
disclosureDeclare equipment family; function and capacity; configuration; BOM coverage; integrated storage and interfaces; cooling and power architecture; firmware state; factory-gate or delivered state; packaging; geography; time period; yields; allocation; exclusions; and any use, maintenance, delivery, or end-of-life extension.
rule_idApplies toRulesource_ids
boundary_identityproduct identityInclude only units whose principal identity matches one CPC 45289 equipment family. Route multifunction or unclear products to manual_review before modelling.unstats-cpc-3-0-45289
boundary_productiondefault foreground systemInclude attributable parts and subassemblies, PCBA or module assembly where performed, final assembly, functional and power testing, warehousing, and packaging through the manufacturing gate.etsi-es-203-199-v1-3-1
boundary_partsproduct compositionIdentify applicable electronic, mechanical, cooling, cable, power, storage, interface, and packaging parts from a configuration-specific BOM; disclose excluded part categories and the reason for exclusion.etsi-es-203-199-v1-3-1
boundary_coolingcooling and power supportInclude cooling hardware and coolant physically shipped with the unit in the BOM. Allocate manufacturing-facility cooling and power-support burdens to production; exclude data-centre or customer-site cooling, UPS, and building overhead from the factory-gate product unless a separately declared downstream extension is modelled.etsi-es-203-199-v1-3-1
boundary_deliverypackaging and distributionInventory packaging at the plant. Outbound delivery begins after the factory gate and is excluded by default; when included, model it as a conditional route-specific process and preserve the factory-gate result.etsi-es-203-199-v1-3-1
boundary_exclusionsoverlap controlExclude complete computers and servers, complete systems, storage units, input or output peripherals, expansion cards, integrated circuits, network communications equipment, and passive parts or accessories covered by other product identities.unstats-cpc-3-0-45289
boundary_use_and_end_of_lifedownstream extensionsDo not include use electricity, maintenance replacement, reuse, recycling, or disposal in the default production dataset. If a lifecycle model adds them, disclose operating lifetime, state-time profile, electricity geography, maintenance, and end-of-life scenario separately.etsi-es-203-199-v1-3-1

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
parts_supply_and_kittingParts, subassemblies, and kittingrequiredAll foreground packagesSupplier dataset interface and receipt-to-line preparationkg kitted parts per kg accepted net product
assembly_and_integrationPCBA, module, and final assemblyrequiredAll foreground packages; purchased completed modules remain upstream product inputsForeground production and configuration integrationkg assembled unit per kg accepted net product
functional_testFunctional, capacity, thermal, and power testingrequiredAll foreground packagesAcceptance testing and reject accountingkg accepted tested unit per kg test input
packaging_and_factory_gateWarehousing, packaging, and factory-gate releaserequiredAll foreground packagesReference-product completion1 kg finished net product at factory gate
outbound_deliveryOutbound delivery extensionconditionalInclude only when the declared dataset boundary extends beyond the manufacturing gateRoute-specific delivery extensiontonne-km and kg delivered product

Process: Parts, subassemblies, and kitting (parts_supply_and_kitting)

Inputs

Product flows
Electronic parts, PCBAs, and processing modules (electronic_parts_and_pcbas)

Record all purchased electronic parts and assemblies attributable to the selected configuration, including processor or accelerator modules, printed boards, populated PCBAs, memory and control electronics. Integrated circuits are inputs, not the CPC 45289 reference product.

  • Selected flow: Supplier-specific electronic parts and PCBA product flows
  • Flow property / unit: Mass / kg; board area or die area may be retained as allocation evidence
  • Amount rule: BOM and goods-receipt mass attributable to accepted production, including yield-adjusted upstream quantities when known
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg accepted net product at factory gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_bom_mass_and_kitting
  • Sources: etsi-es-203-199-v1-3-1
Chassis, enclosure, and mechanical hardware (chassis_and_mechanics)

Record the enclosure, rack or board carrier, brackets, fasteners, shields, heat spreaders, and other mechanical items shipped as part of the unit.

  • Selected flow: Supplier-specific mechanical part product flows
  • Flow property / unit: Mass / kg
  • Amount rule: Configuration-specific BOM mass and receipt records
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg accepted net product at factory gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_bom_mass_and_kitting
  • Sources: etsi-es-203-199-v1-3-1
Interfaces, connectors, and cabling (interfaces_connectors_cabling)

Record installed physical interfaces, connectors, transceivers that are integral to the unit, internal cables, and external cables included in the sales package. Stand-alone network communications equipment is excluded.

  • Selected flow: Supplier-specific connector, cable, and integral interface product flows
  • Flow property / unit: Mass / kg
  • Amount rule: BOM mass by interface type and included cable set
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg accepted net product at factory gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_bom_mass_and_kitting
  • Sources: etsi-es-203-199-v1-3-1
Power and integrated cooling parts (power_and_integrated_cooling_parts)

Record power-supply modules, voltage conversion, fans, heat sinks, cold plates, pumps, sealed cooling loops, and coolant physically shipped with the unit. Facility and data-centre support systems are not product parts.

  • Selected flow: Supplier-specific power and integrated cooling product flows
  • Flow property / unit: Mass / kg; coolant by mass or volume with density conversion retained
  • Amount rule: BOM mass and fill records for the shipped configuration
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg accepted net product at factory gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_bom_mass_and_kitting
  • Sources: etsi-es-203-199-v1-3-1
Incidental integrated storage (incidental_integrated_storage)

Record storage only when it is physically integrated and subordinate to the declared CPC 45289 function. A separately presented storage unit or a product whose principal function is storage is outside this PCR.

  • Selected flow: Supplier-specific integrated storage component flow
  • Flow property / unit: Mass / kg and declared capacity in the native storage unit
  • Amount rule: BOM mass and configuration record for subordinate integrated storage
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg accepted net product at factory gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_bom_mass_and_kitting
  • Sources: unstats-cpc-3-0-45289
Waste flows
Elementary flows

Outputs

Product flows
Kitted parts and subassemblies (kitted_parts_and_subassemblies)

Record the complete configuration-specific kit transferred to assembly, including traceability to the selected equipment family and BOM revision.

  • Selected flow: Kitted parts and subassemblies for the declared unit
  • Flow property / unit: Mass / kg
  • Amount rule: Sum of accepted issued component masses less documented receipt or kitting losses
  • Value mode: Calculated value (calculated_value)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per kg kitted output transferred to assembly
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_bom_mass_and_kitting
  • Sources: etsi-es-203-199-v1-3-1
Waste flows
Incoming and kitting waste (incoming_and_kitting_waste)

Record damaged parts, protective films, reels, trays, incoming packaging, and other waste generated before assembly by material and treatment route.

  • Selected flow: Site-specific waste flows by material and treatment route
  • Flow property / unit: Mass / kg
  • Amount rule: Weighed or reconciled waste from the same parts and kitting reporting period
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg accepted net product at factory gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_bom_mass_and_kitting
  • Sources: etsi-es-203-199-v1-3-1
Elementary flows

Process: PCBA, module, and final assembly (assembly_and_integration)

Inputs

Product flows
Kitted parts transferred to assembly (assembly_kitted_input)

Record the mass and configuration of the kit consumed by in-house PCBA, module, and final assembly.

  • Selected flow: Kitted parts and subassemblies for the declared unit
  • Flow property / unit: Mass / kg
  • Amount rule: Line issue and return records reconciled to assembly output and scrap
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per kg assembled unit output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_assembly_energy_and_yield
  • Sources: etsi-es-203-199-v1-3-1
Assembly electricity and facility support (assembly_electricity)

Record metered assembly-line electricity plus an explicitly allocated share of attributable facility power and cooling. Keep the metered load and allocation calculation separable.

  • Selected flow: Electricity supply matching the manufacturing geography and reporting period
  • Flow property / unit: Energy / kWh
  • Amount rule: Metered line electricity plus documented physical allocation of shared facility electricity and cooling
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per kg assembled unit output
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_assembly_energy_and_yield
  • Sources: etsi-es-203-199-v1-3-1
Assembly auxiliaries and coolant charge (assembly_auxiliaries_and_coolant)

Record solder, adhesives, cleaning agents, thermal-interface materials, lubricants, and coolant charged into a shipped integrated cooling system when applicable.

  • Selected flow: Site- and material-specific auxiliary product flows
  • Flow property / unit: Mass / kg or volume with documented density conversion
  • Amount rule: Purchase issue, dosing, or fill records less documented returns
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per kg assembled unit output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_assembly_energy_and_yield
  • Sources: etsi-es-203-199-v1-3-1
Waste flows
Elementary flows

Outputs

Product flows
Assembled and configured unit (assembled_configured_unit)

Record the assembled unit transferred to functional testing with equipment family, configuration, interface, power, cooling, storage, and firmware identifiers preserved.

  • Selected flow: Assembled CPC 45289 unit pending acceptance test
  • Flow property / unit: Mass / kg
  • Amount rule: Measured transfer mass of assembled units
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per kg assembled unit output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_assembly_energy_and_yield
  • Sources: unstats-cpc-3-0-45289
Waste flows
Assembly scrap and residues (assembly_scrap_and_residues)

Record rejected components, board and metal scrap, spent auxiliaries, waste coolant, and other assembly residues by material and treatment route.

  • Selected flow: Site-specific waste flows by material and treatment route
  • Flow property / unit: Mass / kg
  • Amount rule: Weighed waste and material-balance reconciliation for the assembly reporting period
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per kg assembled unit output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_assembly_energy_and_yield
  • Sources: etsi-es-203-199-v1-3-1
Elementary flows

Process: Functional, capacity, thermal, and power testing (functional_test)

Inputs

Product flows
Assembled units entering test (assembled_units_for_test)

Record the configuration and mass of units entering the acceptance-test sequence.

  • Selected flow: Assembled CPC 45289 unit pending acceptance test
  • Flow property / unit: Mass / kg
  • Amount rule: Test-entry count multiplied by measured configuration-specific mass
  • Value mode: Calculated value (calculated_value)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per kg accepted tested unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_test_configuration_power
  • Sources: unstats-cpc-3-0-45289
Test electricity (test_electricity)

Record electricity used by the unit under test and attributable test equipment. Preserve measured power states, workload or capacity settings, duration, and the allocation of shared test benches.

  • Selected flow: Electricity supply matching the test-site geography and reporting period
  • Flow property / unit: Energy / kWh
  • Amount rule: Sum of measured state-specific power multiplied by test duration plus documented physical allocation of shared bench electricity
  • Value mode: Calculated value (calculated_value)
  • Specificity: Technology-specific (technology_specific)
  • Normalization basis: per kg accepted tested unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_test_configuration_power
  • Sources: etsi-es-203-199-v1-3-1
Waste flows
Elementary flows

Outputs

Product flows
Accepted tested unit (accepted_tested_unit)

Record units that pass the declared function, capacity, interface, thermal, power, and firmware acceptance criteria.

  • Selected flow: Accepted CPC 45289 unit before packaging
  • Flow property / unit: Mass / kg
  • Amount rule: Accepted count multiplied by measured configuration-specific net mass
  • Value mode: Calculated value (calculated_value)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per kg accepted tested unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_test_configuration_power
  • Sources: unstats-cpc-3-0-45289
Waste flows
Test rejects and failed parts (test_rejects_and_failed_parts)

Record failed units and parts sent to rework, recovery, or waste treatment without counting reworked units as new product output.

  • Selected flow: Site-specific reject, rework, and waste flows
  • Flow property / unit: Mass / kg
  • Amount rule: Failed count and measured mass by disposition, net of successfully reworked units returned to the same lot
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per kg accepted tested unit
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_test_configuration_power
  • Sources: etsi-es-203-199-v1-3-1
Elementary flows

Process: Warehousing, packaging, and factory-gate release (packaging_and_factory_gate)

Inputs

Product flows
Accepted units entering packaging (accepted_units_for_packaging)

Record accepted units transferred from testing without changing their product identity or net mass basis.

  • Selected flow: Accepted CPC 45289 unit before packaging
  • Flow property / unit: Mass / kg
  • Amount rule: Transfer mass reconciled to factory-gate released product
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg factory-gate reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_packaging_and_warehouse
  • Sources: unstats-cpc-3-0-45289
Packaging materials (packaging_materials)

Record primary, secondary, and tertiary packaging attributable to released products by material. Packaging is not part of the net reference mass.

  • Selected flow: Packaging material product flows by material and recycled-content specification
  • Flow property / unit: Mass / kg
  • Amount rule: Issued packaging less returned or unused material, reconciled to packed released units
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg factory-gate reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_packaging_and_warehouse
  • Sources: etsi-es-203-199-v1-3-1
Warehousing and packaging electricity (packaging_warehouse_electricity)

Record metered or physically allocated electricity for product warehousing, packing, and factory-gate release.

  • Selected flow: Electricity supply matching the manufacturing geography and reporting period
  • Flow property / unit: Energy / kWh
  • Amount rule: Metered electricity or documented physical allocation to released product mass
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg factory-gate reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_packaging_and_warehouse
  • Sources: etsi-es-203-199-v1-3-1
Waste flows
Elementary flows

Outputs

Product flows
Factory-gate reference product (factory_gate_reference_product)

Record accepted finished net product at the manufacturing gate with packaging mass reported separately.

  • Selected flow: Other units of automatic data processing machines b3854d4e-54f5-4fad-9457-2f899c4a1653
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: fixed reference output of 1 kg accepted net product
  • Value mode: Fixed value (fixed_value)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: 1 kg accepted net product at factory gate
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Identity reference (identity_reference)
  • Collection protocol:
  • Sources:
Waste flows
Packaging and warehousing waste (packaging_and_warehouse_waste)

Record damaged packaging, labels, pallets, protective materials, and other warehouse or packing waste by treatment route.

  • Selected flow: Site-specific waste flows by material and treatment route
  • Flow property / unit: Mass / kg
  • Amount rule: Weighed waste reconciled with packaging issue and return records
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg factory-gate reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_packaging_and_warehouse
  • Sources: etsi-es-203-199-v1-3-1
Elementary flows

Process: Outbound delivery extension (outbound_delivery)

Inputs

Product flows
Factory-gate product entering delivery (factory_gate_product_for_delivery)

Record the factory-gate product and packaging mass entering the declared delivery route while preserving the factory-gate result.

  • Selected flow: Other units of automatic data processing machines b3854d4e-54f5-4fad-9457-2f899c4a1653
  • Flow property / unit: Mass / kg
  • Amount rule: shipped net product mass and packaging mass from dispatch records
  • Value mode: Foreground record (foreground_record)
  • Specificity: Route-specific (route_specific)
  • Normalization basis: per declared delivery consignment
  • Basis kind: Transport service (transport_service)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_delivery_route
  • Sources: etsi-es-203-199-v1-3-1
Outbound transport service (outbound_transport_service)

Record each transport leg using actual mode, distance, shipped mass, utilization, and any temperature-control or special-handling requirement.

  • Selected flow: Route- and mode-specific freight transport service
  • Flow property / unit: Transport service / tonne-km
  • Amount rule: shipped mass in tonnes multiplied by leg distance in kilometres, adjusted only by the selected transport dataset convention
  • Value mode: Calculated value (calculated_value)
  • Specificity: Route-specific (route_specific)
  • Normalization basis: per declared delivery consignment
  • Basis kind: Transport service (transport_service)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_delivery_route
  • Sources: etsi-es-203-199-v1-3-1
Waste flows
Elementary flows

Outputs

Product flows
Delivered product (delivered_product)

Record delivered product as an explicit downstream extension; do not replace or obscure the factory-gate reference output.

  • Selected flow: Delivered CPC 45289 unit with route declaration
  • Flow property / unit: Mass / kg
  • Amount rule: delivered net product mass confirmed by dispatch and receipt records
  • Value mode: Foreground record (foreground_record)
  • Specificity: Route-specific (route_specific)
  • Normalization basis: per declared delivery consignment
  • Basis kind: Transport service (transport_service)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_delivery_route
  • Sources: etsi-es-203-199-v1-3-1
Waste flows
Elementary flows

7. Allocation and Co-product Handling

rule_idApplies toRulesource_ids
allocation_avoidshared production and test processesAvoid allocation by subdividing lines, meters, test benches, and records by configuration or production lot whenever feasible.etsi-es-203-199-v1-3-1
allocation_physicalshared facility electricity, cooling, warehousing, and assembly supportWhen subdivision is not feasible, use a causal physical driver. Prefer board area for PCB processes, good die area for integrated-circuit processes, machine time or metered energy for assembly and test, and mass for other components and warehousing.etsi-es-203-199-v1-3-1
allocation_economic_fallbackshared processes without a defensible physical relationshipUse economic allocation only when a physical relation is insufficient; disclose prices, period, currency, co-products, and a sensitivity check.etsi-es-203-199-v1-3-1
allocation_reworkrejects and reworkReturn successfully reworked units to the originating lot without a second product credit. Assign measured rework inputs and unrecovered reject treatment to the lot that generated them.etsi-es-203-199-v1-3-1
allocation_recyclingproduction scrap and recoverable materialsRecord scrap mass and treatment output explicitly. Do not apply an avoided-burden or recycling credit inside the foreground inventory unless the downstream study declares and consistently applies a recycling method.etsi-es-203-199-v1-3-1

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_bom_mass_and_kittingparts_supply_and_kittingproduct BOM, receipts, issued kits, and incoming wasteBOM export; goods receipt; scale record; material dispositionequipment family; product and BOM revision; supplier part id; part category; quantity; measured unit mass; board area; die area where available; storage capacity; interface count; cooling and power configuration; waste mass and routeExport controlled BOM, reconcile receipts and line issues, and weigh representative parts and wastes with calibrated scaleskg; item; m2 board; mm2 die; native capacity uniteach BOM revision and production lotsame reporting period as assembly outputall sites and suppliers contributing to the declared configurationSum attributable input and waste by configuration, convert counts with measured unit mass, and normalize to accepted net product massapproved BOM; receiving records; calibration certificate; supplier dataset reference; reconciliation report
cp_assembly_energy_and_yieldassembly_and_integrationassembly inputs, electricity, auxiliaries, output, and scrapline meter; production execution record; issue and return log; waste ticketline; configuration; start and end meter; output count and mass; machine time; facility cooling and power allocation driver; auxiliary and coolant issue; scrap and routeRead dedicated meters where available and document physical allocation of shared facility loads; reconcile material issue, output, returns, and scrapkWh; kg; item; machine-hourper lot with monthly meter reconciliationrepresentative contiguous production period, normally at least one montheach assembly site in scopeAllocate shared loads with the declared physical driver and normalize net inputs to kg assembled outputmeter calibration; production log; allocation workbook; mass-balance closure; waste receipt
cp_test_configuration_powerfunctional_testfunction, capacity, thermal, power, acceptance, and reject recordstest-system export; power analyser; thermal log; rework and disposition logequipment family; configuration; firmware; native capacity and test method; interface state; cooling state; power mode; workload; W; duration; ambient condition; pass or fail; reject mass and dispositionRun the declared acceptance sequence with calibrated instruments and retain mode-time and workload settingsW; kWh; native capacity unit; degree C; kg; itemeach tested lot and configurationsame period as reported tested outputeach test site and bench type in scopeSum state-specific energy, allocate shared bench energy by measured test time, and normalize to accepted tested masstest procedure; calibration records; raw result files; pass-fail log; rework closure
cp_packaging_and_warehousepackaging_and_factory_gateaccepted product, packaging, warehouse energy, and packing wastedispatch release; packaging issue; scale record; warehouse meter; waste ticketnet product mass; accepted count; packaging material and mass; pallet reuse; meter or allocation driver; released quantity; packing waste and routeReconcile accepted product to dispatch release, weigh packaging by material, and meter or physically allocate warehouse and packing energykg; item; kWhper lot with monthly reconciliationsame reporting period as factory-gate releaseall packing and warehouse sites in scopeNormalize packaging, energy, and waste to 1 kg released net product while retaining packaging separatelydispatch record; packaging specification; scale and meter calibration; waste receipt
cp_delivery_routeoutbound_deliveryconditional outbound deliverybill of lading; carrier record; dispatch and receipt confirmationorigin; destination; mode; leg distance; net and gross shipped mass; utilization; special handling; delivered mass; loss or damageCapture actual route legs and carrier data; use modelled routes only when flagged as a scenariokg; tonne-km; kmeach shipment or representative route classdeclared delivery periodall routes included in the extensionCalculate tonne-km per leg, sum route results, and keep delivery separate from factory-gate productionbill of lading; carrier invoice; route evidence; receipt confirmation

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
calc_count_to_massitem-based production and reject recordsmass = item count multiplied by measured configuration-specific mass per item from the same perioditem count; measured unit masskg by flow and configuration
calc_bom_mass_balanceparts, product, and waste reconciliationincoming attributable mass = accepted net product mass + returned material + recoverable scrap + other waste + measured inventory change; investigate and disclose residual imbalanceBOM and issue mass; product mass; returns; scrap; waste; inventory changemass-balance statement and residual
calc_process_energyassembly, testing, warehousing, and packagingnormalized energy = measured dedicated energy plus physically allocated shared energy divided by accepted process output massstart and end meters; shared-load total; allocation driver; accepted output masskWh per kg process outputetsi-es-203-199-v1-3-1
calc_power_profiledevice power qualifier and optional use-stage extensionuse energy = sum of state-specific power multiplied by time in that state; retain workload, capacity, cooling, and interface settingsW by state; hours by state; workload and configurationkWh for the declared profileetsi-es-203-199-v1-3-1
calc_deliveryconditional outbound deliverytransport service = sum over route legs of shipped tonnes multiplied by leg kilometresshipped mass; distance; mode; route legtonne-km by mode and routeetsi-es-203-199-v1-3-1

Data Quality Requirements

requirement_idApplies toRequirementEvidence
dq_identityproduct identityEvidence shall demonstrate one CPC 45289 equipment family and principal function; an ambiguous or multifunction product requires manual_review.product specification; functional block diagram; classification review against unstats-cpc-3-0-45289
dq_configurationfunction and comparabilityPreserve native capacity, test method, firmware, interfaces, PCB and subassembly configuration, incidental storage, power supply, and integrated cooling for each reported configuration.controlled configuration and test records
dq_bomproduct compositionCover all applicable electronic, mechanical, cable, power, cooling, storage, interface, auxiliary, and packaging categories, and explain any excluded category.controlled BOM; supplier datasets; mass-balance reconciliation; etsi-es-203-199-v1-3-1
dq_energyproduction and power profileUse calibrated measurements where feasible; disclose meter coverage, shared-load allocation, operating state, workload, test duration, and electricity geography.meter and analyser calibration; raw logs; allocation workbook; etsi-es-203-199-v1-3-1
dq_temporal_geographicall foreground and upstream dataState the reporting period, manufacturing sites, supplier geography, electricity geography, and technological representativeness; explain substitutions.site and supplier records; dataset metadata
dq_yield_and_wasteall production processesReconcile accepted output, rejects, rework, scrap, and waste treatment to the same lot and period without double counting reworked product.production logs; rework closure; waste receipts; mass balance
dq_boundarypackaging, delivery, cooling, use, and end-of-lifeDisclose whether each boundary element is included and keep any downstream extension separable from the factory-gate result.boundary statement; process map; route or scenario records

9. Validation Rules

rule_idApplies toRulesource_ids
validate_identityclassification and product nameThe product shall match one listed CPC 45289 equipment family and shall not be represented only by the residual title "other unit".unstats-cpc-3-0-45289
validate_reference_flowquantitative referenceThe reference output shall use product flow b3854d4e-54f5-4fad-9457-2f899c4a1653, Mass 93a60a56-a3c8-11da-a746-0800200b9a66, Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66, and kg, normalized to accepted net product mass.
validate_required_qualifiersdataset metadataEquipment family, function, native capacity and test, power states, chassis or board form, PCB and subassembly configuration, incidental storage, interfaces, integrated cooling, power supply, firmware state, net mass, packaging, delivery boundary, geography, period, lot, yield, and allocation shall be present or explicitly not applicable.etsi-es-203-199-v1-3-1
validate_no_overlapcategory exclusionReject server or complete-computer datasets, complete systems, separate storage units, input or output peripherals, graphics, video, sound, or network cards, integrated circuits, network communications equipment, and passive parts or accessories.unstats-cpc-3-0-45289
validate_bom_and_mass_balanceinventory completenessThe BOM categories and process mass balance shall reconcile accepted net product, packaging, returns, rejects, scrap, wastes, and inventory change; exclusions and residual imbalance shall be disclosed.etsi-es-203-199-v1-3-1
validate_power_and_coolingenergy and thermal boundaryPower shall be tied to operating state, workload or capacity, duration, and instrument method. Integrated cooling shipped with the unit shall be in the BOM; manufacturing-facility and downstream data-centre cooling shall remain separately identified.etsi-es-203-199-v1-3-1
validate_delivery_boundaryfactory-gate and delivered resultsPackaging shall be separate from net reference mass, and outbound delivery shall be absent from the default result or reported as a separable route-specific extension.etsi-es-203-199-v1-3-1
validate_allocationshared processesThe dataset shall state each shared process, allocation hierarchy, physical driver, and fallback sensitivity; unexplained economic or generic mass allocation fails validation.etsi-es-203-199-v1-3-1
validate_manual_reviewbroad-leaf ambiguityIf the equipment family, principal function, or boundary against excluded server, complete-machine, storage, peripheral, expansion-card, integrated-circuit, communications, or passive-part identities cannot be resolved, validation is inconclusive and the record shall be routed to manual_review.unstats-cpc-3-0-45289

10. Published Dataset Profile

FieldValue
dataset_roleForeground production dataset for one declared CPC 45289 equipment family and configuration at the manufacturing gate
downstream_useSecondary dataset and background dataset for product, process, and lifecyclemodel construction when identity, configuration, capacity, and boundary are compatible
allowed_useConfiguration-specific product footprinting; supply-chain modelling; data-centre or computing-system component inventories; scenario analysis with separately modelled delivery, use, maintenance, and end-of-life extensions
excluded_useDirect comparison across unlike equipment families or capacities; representation of servers, complete computers or systems, storage units, peripherals, expansion cards, integrated circuits, communications equipment, or passive parts; use-stage or delivered claims from a factory-gate-only dataset
required_metadataEquipment family; principal function; native capacity and test method; power modes; operating profile if used; chassis or board form; PCB and subassembly configuration; incidental storage; interfaces; integrated cooling and coolant; power supply; firmware state; net mass; packaging; delivery boundary; manufacturing and electricity geography; reporting period; lot; yield; allocation; BOM coverage; exclusions; data sources
required_quality_disclosureForeground versus upstream data shares; supplier dataset coverage; measurement and calibration coverage; BOM and mass-balance residual; shared-load allocation; temporal, geographic, and technological representativeness; missing part categories; rework and waste closure; downstream scenario assumptions
update_triggerChange of equipment family, principal function, native capacity test, major PCB or semiconductor generation, chassis or interface architecture, integrated storage, cooling or power design, firmware that changes function or power, manufacturing site or electricity supply, supplier route, packaging, delivery boundary, allocation method, or source evidence

11. Data Sources

Source idTypeReferenceUsed for
unstats-cpc-3-0-45289Official guidance (official_guidance)United Nations Statistics Division, Central Product Classification Version 3.0, Explanatory Notes, subclass 45289, updated 30 June 2025, https://unstats.un.org/unsd/classifications/Econ/Download/In%20Text/CPC_Ver_3.0_Exp_Notes_30Jun2025.pdf, retrieved 2026-08-09Semantic equipment-family boundary; included and excluded products; classification ambiguity checks
etsi-es-203-199-v1-3-1Standard (standard)ETSI ES 203 199 V1.3.1, Environmental Engineering: Methodology for environmental Life Cycle Assessment of Information and Communication Technology goods, networks and services, February 2015, https://www.etsi.org/deliver/etsi_es/203100_203199/203199/01.03.01_60/es_203199v010301p.pdf, retrieved 2026-08-09Functional-unit qualifiers; product composition and BOM coverage; assembly, warehousing, and packaging boundary; power modes; cooling and support goods; data collection; allocation; reporting and quality rules

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 7
Rule IDApplies toRuleSource IDs
boundary_identityproduct identityInclude only units whose principal identity matches one CPC 45289 equipment family. Route multifunction or unclear products to manual_review before modelling.unstats-cpc-3-0-45289
boundary_productiondefault foreground systemInclude attributable parts and subassemblies, PCBA or module assembly where performed, final assembly, functional and power testing, warehousing, and packaging through the manufacturing gate.etsi-es-203-199-v1-3-1
boundary_partsproduct compositionIdentify applicable electronic, mechanical, cooling, cable, power, storage, interface, and packaging parts from a configuration-specific BOM; disclose excluded part categories and the reason for exclusion.etsi-es-203-199-v1-3-1
boundary_coolingcooling and power supportInclude cooling hardware and coolant physically shipped with the unit in the BOM. Allocate manufacturing-facility cooling and power-support burdens to production; exclude data-centre or customer-site cooling, UPS, and building overhead from the factory-gate product unless a separately declared downstream extension is modelled.etsi-es-203-199-v1-3-1
boundary_deliverypackaging and distributionInventory packaging at the plant. Outbound delivery begins after the factory gate and is excluded by default; when included, model it as a conditional route-specific process and preserve the factory-gate result.etsi-es-203-199-v1-3-1
boundary_exclusionsoverlap controlExclude complete computers and servers, complete systems, storage units, input or output peripherals, expansion cards, integrated circuits, network communications equipment, and passive parts or accessories covered by other product identities.unstats-cpc-3-0-45289
boundary_use_and_end_of_lifedownstream extensionsDo not include use electricity, maintenance replacement, reuse, recycling, or disposal in the default production dataset. If a lifecycle model adds them, disclose operating lifetime, state-time profile, electricity geography, maintenance, and end-of-life scenario separately.etsi-es-203-199-v1-3-1
Allocation rules · 5
Rule IDApplies toRuleSource IDs
allocation_avoidshared production and test processesAvoid allocation by subdividing lines, meters, test benches, and records by configuration or production lot whenever feasible.etsi-es-203-199-v1-3-1
allocation_physicalshared facility electricity, cooling, warehousing, and assembly supportWhen subdivision is not feasible, use a causal physical driver. Prefer board area for PCB processes, good die area for integrated-circuit processes, machine time or metered energy for assembly and test, and mass for other components and warehousing.etsi-es-203-199-v1-3-1
allocation_economic_fallbackshared processes without a defensible physical relationshipUse economic allocation only when a physical relation is insufficient; disclose prices, period, currency, co-products, and a sensitivity check.etsi-es-203-199-v1-3-1
allocation_reworkrejects and reworkReturn successfully reworked units to the originating lot without a second product credit. Assign measured rework inputs and unrecovered reject treatment to the lot that generated them.etsi-es-203-199-v1-3-1
allocation_recyclingproduction scrap and recoverable materialsRecord scrap mass and treatment output explicitly. Do not apply an avoided-burden or recycling credit inside the foreground inventory unless the downstream study declares and consistently applies a recycling method.etsi-es-203-199-v1-3-1
Validation rules · 9
Rule IDApplies toRuleSource IDs
validate_identityclassification and product nameThe product shall match one listed CPC 45289 equipment family and shall not be represented only by the residual title \"other unit\".unstats-cpc-3-0-45289
validate_reference_flowquantitative referenceThe reference output shall use product flow b3854d4e-54f5-4fad-9457-2f899c4a1653, Mass 93a60a56-a3c8-11da-a746-0800200b9a66, Units of mass 93a60a57-a4c8-11da-a746-0800200c9a66, and kg, normalized to accepted net product mass.
validate_required_qualifiersdataset metadataEquipment family, function, native capacity and test, power states, chassis or board form, PCB and subassembly configuration, incidental storage, interfaces, integrated cooling, power supply, firmware state, net mass, packaging, delivery boundary, geography, period, lot, yield, and allocation shall be present or explicitly not applicable.etsi-es-203-199-v1-3-1
validate_no_overlapcategory exclusionReject server or complete-computer datasets, complete systems, separate storage units, input or output peripherals, graphics, video, sound, or network cards, integrated circuits, network communications equipment, and passive parts or accessories.unstats-cpc-3-0-45289
validate_bom_and_mass_balanceinventory completenessThe BOM categories and process mass balance shall reconcile accepted net product, packaging, returns, rejects, scrap, wastes, and inventory change; exclusions and residual imbalance shall be disclosed.etsi-es-203-199-v1-3-1
validate_power_and_coolingenergy and thermal boundaryPower shall be tied to operating state, workload or capacity, duration, and instrument method. Integrated cooling shipped with the unit shall be in the BOM; manufacturing-facility and downstream data-centre cooling shall remain separately identified.etsi-es-203-199-v1-3-1
validate_delivery_boundaryfactory-gate and delivered resultsPackaging shall be separate from net reference mass, and outbound delivery shall be absent from the default result or reported as a separable route-specific extension.etsi-es-203-199-v1-3-1
validate_allocationshared processesThe dataset shall state each shared process, allocation hierarchy, physical driver, and fallback sensitivity; unexplained economic or generic mass allocation fails validation.etsi-es-203-199-v1-3-1
validate_manual_reviewbroad-leaf ambiguityIf the equipment family, principal function, or boundary against excluded server, complete-machine, storage, peripheral, expansion-card, integrated-circuit, communications, or passive-part identities cannot be resolved, validation is inconclusive and the record shall be routed to manual_review.unstats-cpc-3-0-45289
Processes and inputs/outputs · 5
Process IDProcess nameInput flowsOutput flows
parts_supply_and_kittingParts, subassemblies, and kitting52
assembly_and_integrationPCBA, module, and final assembly32
functional_testFunctional, capacity, thermal, and power testing22
packaging_and_factory_gateWarehousing, packaging, and factory-gate release32
outbound_deliveryOutbound delivery extension21

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page

1. Scope and Applicability2. Product Category Identity3. Reference Flow4. Measurement and Unit Rules5. System BoundaryBoundary Abstraction6. Process Inventory StructureProcess MapProcess: Parts, subassemblies, and kitting (parts_supply_and_kitting)InputsProduct flowsElectronic parts, PCBAs, and processing modules (electronic_parts_and_pcbas)Chassis, enclosure, and mechanical hardware (chassis_and_mechanics)Interfaces, connectors, and cabling (interfaces_connectors_cabling)Power and integrated cooling parts (power_and_integrated_cooling_parts)Incidental integrated storage (incidental_integrated_storage)Waste flowsElementary flowsOutputsProduct flowsKitted parts and subassemblies (kitted_parts_and_subassemblies)Waste flowsIncoming and kitting waste (incoming_and_kitting_waste)Elementary flowsProcess: PCBA, module, and final assembly (assembly_and_integration)InputsProduct flowsKitted parts transferred to assembly (assembly_kitted_input)Assembly electricity and facility support (assembly_electricity)Assembly auxiliaries and coolant charge (assembly_auxiliaries_and_coolant)Waste flowsElementary flowsOutputsProduct flowsAssembled and configured unit (assembled_configured_unit)Waste flowsAssembly scrap and residues (assembly_scrap_and_residues)Elementary flowsProcess: Functional, capacity, thermal, and power testing (functional_test)InputsProduct flowsAssembled units entering test (assembled_units_for_test)Test electricity (test_electricity)Waste flowsElementary flowsOutputsProduct flowsAccepted tested unit (accepted_tested_unit)Waste flowsTest rejects and failed parts (test_rejects_and_failed_parts)Elementary flowsProcess: Warehousing, packaging, and factory-gate release (packaging_and_factory_gate)InputsProduct flowsAccepted units entering packaging (accepted_units_for_packaging)Packaging materials (packaging_materials)Warehousing and packaging electricity (packaging_warehouse_electricity)Waste flowsElementary flowsOutputsProduct flowsFactory-gate reference product (factory_gate_reference_product)Waste flowsPackaging and warehousing waste (packaging_and_warehouse_waste)Elementary flowsProcess: Outbound delivery extension (outbound_delivery)InputsProduct flowsFactory-gate product entering delivery (factory_gate_product_for_delivery)Outbound transport service (outbound_transport_service)Waste flowsElementary flowsOutputsProduct flowsDelivered product (delivered_product)Waste flowsElementary flows7. Allocation and Co-product Handling8. Foreground Data Collection, Calculation, and Quality RulesData Collection ProtocolsCalculation RulesData Quality Requirements9. Validation Rules10. Published Dataset Profile11. Data Sources