TianGong PCR产品类别规则

Instruments and apparatus (except cathode-ray oscilloscopes and oscillographs) for measuring or checking voltage, current, resistance or power, without a recording device (except electricity production or supply meters)

Instruments and apparatus (except cathode-ray oscilloscopes and oscillographs) for measuring or checking voltage, current, resistance or power, without a recording……

Lifecycle status
Candidate
Content maturity
Authored methodology
Current version
No published version
Readiness
Review required
Last updated

Methodology and translation states come from the source record; publishing this website does not change their review status.

Content languages

zh-CN · Aligned
Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:48243 · exact

Source

1. Scope and Applicability

This PCR applies to the foreground manufacture of finished instruments and apparatus whose principal function is measuring or checking voltage, current, electrical resistance, or electrical power and that do not contain a recording device. Typical covered products include non-recording digital or analogue multimeters, voltmeters, ammeters, ohmmeters, and wattmeters when their declared product identity remains within this boundary.

The PCR excludes cathode-ray oscilloscopes and oscillographs; instruments whose defining function includes recording measured values; electricity production or supply meters; instruments for measuring or checking other electrical quantities not covered by the four named quantities; telecommunications test instruments classified outside this category; and accessories, replacement parts, calibration services, or software supplied independently of the finished instrument. A multifunction product is covered only when its declared principal product identity meets this scope and any recording function is absent.

The default foreground boundary begins with purchased materials, components, subassemblies, packaging, and energy received at the manufacturing site and ends with a conforming finished product at the factory gate. Upstream production of purchased inputs is represented by linked upstream datasets. Distribution, use, maintenance, and end-of-life are outside the default foreground package unless a study explicitly extends the boundary and reports those added stages separately.

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.metal-products-machinery-and-equipment.medical-appliances-precision-and-optical-instruments-watches-and-clocks.instruments-and-apparatus-except-cathode-ray-oscilloscopes-and-oscillographs-for-measur-2511b092
classification_refsCPC 3.0: 48243 (exact classification reference; the classification mapping remains governed outside this PCR)
covered_productsFinished non-recording instruments and apparatus for measuring or checking voltage, current, resistance, or power
excluded_productsCathode-ray oscilloscopes and oscillographs; recording instruments; electricity production or supply meters; other-electrical-quantity instruments; separately supplied parts, accessories, software, and services
representative_productA finished non-recording electrical measuring instrument, such as a handheld or bench multimeter, supplied at the factory gate
production_routePurchased electronic and mechanical inputs, optional in-house component manufacture, final electromechanical assembly, calibration and functional/safety/EMC verification as applicable, and packaging
market_stateFinished product, manufactured; production mix, at plant

3. Reference Flow

FieldValue
WhatProvide a finished instrument capable of the declared voltage, current, resistance, or power measurement/checking function without a recording device
How much1 kg of finished instrument at the factory gate
How wellMeets the declared measurement functions, ranges, accuracy specification, safety category, and applicable conformity requirements for the represented model or product family
How long or cycleOne production reporting period; service life is not represented by this cradle-to-gate reference flow and must be declared separately for use-stage comparisons
reference_flow_linkOne kilogram of the Tiangong reference product flow defined below
FieldValue
Reference amount1 kg
Reference product flowInstruments and apparatus (except cathode-ray oscilloscopes and oscillographs) for measuring or checking voltage, current, resistance or power, without a recording device (except electricity production or supply meters) 7ecc1c5a-4a45-4d93-8648-9a86405e3d20
Reference flow propertyMass 93a60a56-a3c8-11da-a746-0800200b9a66
Reference unit groupUnits of mass 93a60a57-a4c8-11da-a746-0800200c9a66
Reference unitkg
Required qualifiersinstrument type and model or product family; measured quantities; measurement ranges; accuracy specification or class; safety measurement category and rated voltage where applicable; analogue or digital indication; explicit absence of a recording device; power-supply and included-battery state; included leads, probes, accessories, manuals, and packaging; production route; manufacturing geography; reporting period

When constructing a foreground data package, every required qualifier must be declared in dataset metadata, process notes, the reference-flow comment, the product description, or an equivalent package field. Missing qualifiers make the category identity or reference flow incomplete.

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
reference_product_massReference product and all mass-normalized inventory resultsMass 93a60a56-a3c8-11da-a746-0800200b9a66kgNormalize the foreground package to exactly 1 kg of conforming finished reference product. Report whether included batteries, test leads, probes, manuals, accessories, and sales packaging are inside that mass.
count_to_mass_conversionSource records available only as instruments, assemblies, or packages by countMass 93a60a56-a3c8-11da-a746-0800200b9a66kgConvert counts to mass only with measured net or gross mass for the represented model and lot; retain the count, measured mass, sample size, and packaging convention.
energy_normalizationElectricity and other energy used by in-house manufacturing, assembly, calibration, testing, and packagingEnergykWh or MJPreserve the metered unit and conversion factor, separate energy carriers, and divide attributable energy by conforming finished-product mass from the same reporting period.
measurement_quality_identityProduct conformance recordsDeclared measurement result and uncertainty or toleranceDeclared engineering unitRetain the tested quantity, range, set point, observed result, tolerance or uncertainty, equipment identifier, calibration status, and pass/fail decision; do not convert a product performance result into an inventory mass or energy amount.

5. System Boundary

Boundary Abstraction

FieldValue
declared_starting_conditionPurchased materials, electronic and electromechanical components, housings, subassemblies, packaging, and energy received at the manufacturing site
starting_condition_roleForeground manufacturing gate; upstream burdens of purchased inputs are supplied by linked secondary or background datasets
product_classification_scopeFinished non-recording instruments for measuring or checking voltage, current, resistance, or power within the semantic product boundary represented by CPC 3.0 code 48243
recursive_input_ruleIf an input is itself a product in this same category, record it as a visible product input and link an upstream dataset; do not recursively reproduce its manufacture inside the receiving process
upstream_dataset_requirementEvery material, component, subassembly, packaging, energy, transport, and treatment input crossing the foreground boundary requires a named upstream dataset or a disclosed unresolved data gap
disclosureDeclare manufacturing sites and routes; included product contents and packaging; in-house versus purchased subassemblies; allocation and cut-off decisions; testing scope; data period; geography; and all excluded life-cycle stages
rule_idApplies toRulesource_ids
sb_foreground_manufacturingforeground_system_boundaryInclude all directly controlled and attributable in-house component manufacture, electromechanical assembly, firmware loading when part of manufacture, calibration, functional verification, applicable safety and EMC tests, quality control, rework, cleaning, and packaging through the finished-product factory gate.iec-63366-2025; eu-pef-2021-2279
sb_purchased_inputspurchased_input_boundaryRecord the full product-specific bill of materials and packaging, purchased subassemblies, energy, auxiliaries, intra-site handling, and waste/treatment outputs; connect each purchased input to an upstream dataset rather than omitting it from the foreground package.eu-pef-2021-2279
sb_compliance_evidenceproduct_conformance_boundaryInclude the activity data for tests actually performed for the represented product route and retain product safety, EMC, calibration, and restricted-substance documentation; a cited standard does not substitute for the product's test or supplier records.iec-61010-1-2010-amd1-2016; iec-61326-1-2020; iec-63000-2016-amd1-2022
sb_no_silent_cutoffforeground_cutoffDo not silently omit known production inputs, outputs, or process stages. Any exclusion must identify the omitted flow or stage, the reason and materiality basis, the governing study method, and the expected effect on completeness.iso-14044-2006; eu-pef-2021-2279
sb_extended_stagesdownstream_extensionKeep distribution, use, maintenance, and end-of-life outside the default foreground package; if added for a specific study, model and disclose them as an explicit boundary extension without changing the canonical cradle-to-gate reference-flow identity.iec-63366-2025; iso-14044-2006

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
inhouse_component_manufactureIn-house component and subassembly manufactureconditionalInclude when the reporting facility manufactures or materially transforms circuit assemblies, sensors, shunts, housings, terminals, wiring assemblies, or other product componentsForeground component manufacture1 kg of accepted in-house component or subassembly output
final_instrument_assemblyFinal instrument assembly and configurationrequiredAlways include for a manufactured finished instrumentForeground electromechanical assembly1 kg of assembled instrument before final calibration and release
calibration_test_packagingCalibration, verification, release, and packagingrequiredAlways include; record only the tests and packaging activities applicable to the represented routeForeground calibration, conformance verification, quality release, and packaging1 kg of conforming finished reference product

Process: In-house component and subassembly manufacture (inhouse_component_manufacture)

Inputs

Product flows
Raw materials, parts, and process materials for in-house manufacture (inhouse_material_inputs)

Record product-specific materials and parts entering each in-house component or subassembly operation from purchasing, stores, or another site.

  • Selected flow: Supplier-specific material, part, or process material; resolve each concrete flow during dataset construction
  • Flow property / unit: Mass / kg
  • Amount rule: Measured receipts and stock-adjusted consumption attributable to accepted component or subassembly output
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg of accepted in-house component or subassembly output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_inhouse_materials
  • Sources: eu-pef-2021-2279; iec-63000-2016-amd1-2022
Energy supplied to in-house manufacture (inhouse_energy)

Record electricity and other energy carriers consumed by the included in-house operations, separated by carrier and supply dataset.

  • Selected flow: Site- and carrier-specific energy supply; resolve during dataset construction
  • Flow property / unit: Energy / kWh or MJ
  • Amount rule: Submetered consumption, or documented allocation from a complete site meter when submetering is unavailable
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg of accepted in-house component or subassembly output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_inhouse_energy
  • Sources: eu-pef-2021-2279
Waste flows

No waste input is prescribed. Record a waste input only when an actual recovered or waste-derived material crosses into the process, with its treatment status and upstream burden convention disclosed.

Elementary flows

Record direct resource inputs only when they cross from the environment into the in-house process and are not already represented by a product-flow supply dataset.

Outputs

Product flows
Accepted in-house components and subassemblies (inhouse_component_output)

Record the accepted component or subassembly mass transferred to final instrument assembly.

  • Selected flow: Product-specific component or subassembly; resolve during dataset construction
  • Flow property / unit: Mass / kg
  • Amount rule: Measured accepted output mass
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg of accepted in-house component or subassembly output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_inhouse_outputs
  • Sources: eu-pef-2021-2279
Waste flows
In-house manufacturing scrap, rejects, and treatment residues (inhouse_waste_outputs)

Record each material-specific scrap, rejected component, wastewater, spent bath, and other waste output with destination and recovery or disposal route.

  • Selected flow: Material- and treatment-specific waste flow; resolve during dataset construction
  • Flow property / unit: Mass / kg
  • Amount rule: Measured waste shipment, treatment, or internal transfer mass by waste type
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg of accepted in-house component or subassembly output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_inhouse_outputs
  • Sources: eu-pef-2021-2279
Elementary flows
Direct emissions from in-house component manufacture (inhouse_direct_emissions)

Record measured or legally reported releases to air, water, or soil from included in-house operations without duplicating emissions already represented in upstream energy or material datasets.

  • Selected flow: Substance- and compartment-specific elementary flow; resolve during dataset construction
  • Flow property / unit: Mass / kg
  • Amount rule: Measured release or calculation from measured concentration and discharge volume using the declared monitoring method
  • Value mode: Calculated value (calculated_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg of accepted in-house component or subassembly output
  • Basis kind: Process output (process_output)
  • Evidence kind: Calculated from collection (calculated_from_collection)
  • Collection protocol: cp_inhouse_outputs
  • Sources: eu-pef-2021-2279

Process: Final instrument assembly and configuration (final_instrument_assembly)

Inputs

Product flows
Electronic, sensing, and electromechanical bill-of-material inputs (assembly_electronic_inputs)

Record populated or bare circuit assemblies, sensors, shunts, displays, switches, terminals, connectors, wiring, power modules, batteries when included, and other electronic or electromechanical items by supplier and part identity.

  • Selected flow: Supplier- and part-specific product flow; resolve during dataset construction
  • Flow property / unit: Mass / kg
  • Amount rule: Product-specific bill-of-material quantity reconciled to measured issue, return, and stock-change records
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg of assembled instrument output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_assembly_bom
  • Sources: eu-pef-2021-2279; iec-63000-2016-amd1-2022
Housings, mechanical parts, fasteners, and labels (assembly_mechanical_inputs)

Record housings, frames, shields, knobs, buttons, fasteners, labels, and other mechanical items by material and part identity.

  • Selected flow: Supplier- and part-specific product flow; resolve during dataset construction
  • Flow property / unit: Mass / kg
  • Amount rule: Product-specific bill-of-material quantity reconciled to measured issue, return, and stock-change records
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg of assembled instrument output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_assembly_bom
  • Sources: eu-pef-2021-2279; iec-63000-2016-amd1-2022
Assembly energy and directly consumed auxiliaries (assembly_energy_auxiliaries)

Record electricity, compressed air, solder or joining materials, adhesives, cleaning agents, lubricants, and other directly attributable assembly inputs separately.

  • Selected flow: Site- and material-specific product flow; resolve during dataset construction
  • Flow property / unit: Energy / kWh or MJ for energy; Mass / kg for materials
  • Amount rule: Metered energy and stock-adjusted auxiliary consumption attributable to the assembly process
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg of assembled instrument output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_assembly_energy_auxiliaries
  • Sources: eu-pef-2021-2279
Waste flows

No waste input is prescribed. Reused or recovered assembly inputs must remain visible product or waste-derived inputs according to their actual supply status.

Elementary flows

Record direct elementary inputs only when measured at the assembly process and not represented by a supplied product flow.

Outputs

Product flows
Assembled instrument awaiting calibration and release (assembled_instrument_output)

Record the measured mass transferred to final calibration, verification, and product release.

  • Selected flow: Product-specific uncalibrated assembled instrument; no category-generic UUID is prescribed
  • Flow property / unit: Mass / kg
  • Amount rule: Measured accepted transfer mass
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg of assembled instrument output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_assembly_outputs
  • Sources: eu-pef-2021-2279
Waste flows
Assembly scrap, rejects, and replaced parts (assembly_waste_outputs)

Record assembly scrap, rejected assemblies, removed parts, spent consumables, and their actual destinations without netting them against material inputs.

  • Selected flow: Material- and treatment-specific waste flow; resolve during dataset construction
  • Flow property / unit: Mass / kg
  • Amount rule: Measured waste, reject, and return mass by type and destination
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg of assembled instrument output
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_assembly_outputs
  • Sources: eu-pef-2021-2279
Elementary flows

Record direct releases from cleaning, joining, or other assembly activities only when they occur and are supported by site measurement or a documented calculation from collected records.

Process: Calibration, verification, release, and packaging (calibration_test_packaging)

Inputs

Product flows
Assembled instrument input (test_assembled_input)

Record the mass of assembled instruments entering calibration and verification, including returned rework loops without double counting repeated throughput as new product input.

  • Selected flow: Product-specific uncalibrated assembled instrument; no category-generic UUID is prescribed
  • Flow property / unit: Mass / kg
  • Amount rule: Measured unique input mass plus separately disclosed rework passes
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg of conforming finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_test_inputs
  • Sources: eu-pef-2021-2279
Test, calibration, and packaging energy and consumables (test_energy_consumables)

Record energy used by calibration and test equipment, conditioning, firmware programming, burn-in when performed, and packaging, together with directly consumed calibration and cleaning materials.

  • Selected flow: Site- and carrier-specific energy or material flow; resolve during dataset construction
  • Flow property / unit: Energy / kWh or MJ for energy; Mass / kg for materials
  • Amount rule: Metered consumption or documented allocation to tested and released product
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg of conforming finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_test_energy_consumables
  • Sources: eu-pef-2021-2279; iec-61010-1-2010-amd1-2016; iec-61326-1-2020
Sales packaging and included accessories (packaging_accessory_inputs)

Record primary and secondary sales packaging and all leads, probes, adapters, batteries, manuals, and accessories included with the declared reference product; clearly distinguish included product mass from packaging mass.

  • Selected flow: Material- and supplier-specific packaging or accessory flow; resolve during dataset construction
  • Flow property / unit: Mass / kg
  • Amount rule: Product-specific packaging and accessory bill of materials reconciled to issue and stock-change records
  • Value mode: Foreground record (foreground_record)
  • Specificity: Product-specific (product_specific)
  • Normalization basis: per 1 kg of conforming finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_test_inputs
  • Sources: eu-pef-2021-2279
Waste flows

No waste input is prescribed. Returned instruments entering remanufacture or refurbishment are outside this virgin-manufacture route unless a separately declared route is modelled.

Elementary flows

Record direct elementary inputs only when an actual calibration, conditioning, or test operation draws a resource directly from the environment.

Outputs

Product flows
Conforming finished non-recording electrical measuring instrument (reference_product_output)

Record the released finished-product mass using the exact Tiangong reference product flow and retain the model, function, accuracy, test, accessory, battery, and packaging qualifiers.

  • Selected flow: Instruments and apparatus (except cathode-ray oscilloscopes and oscillographs) for measuring or checking voltage, current, resistance or power, without a recording device (except electricity production or supply meters) 7ecc1c5a-4a45-4d93-8648-9a86405e3d20
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Exactly 1 kg of conforming released reference product after normalization
  • Value mode: Fixed value (fixed_value)
  • Specificity: Generic (generic)
  • Normalization basis: 1 kg reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Identity reference (identity_reference)
  • Sources:
Waste flows
Failed units, replaced parts, and test rejects (test_reject_outputs)

Record failed units and parts leaving the rework loop, including their measured mass, disposition, recovery, or treatment route.

  • Selected flow: Material- and treatment-specific waste flow; resolve during dataset construction
  • Flow property / unit: Mass / kg
  • Amount rule: Measured reject and replaced-part mass leaving the foreground system
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg of conforming finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_test_outputs
  • Sources: eu-pef-2021-2279
Packaging-process waste (packaging_waste_outputs)

Record offcuts, damaged packaging, liners, reels, and other packaging waste generated before the finished product leaves the factory gate.

  • Selected flow: Material- and treatment-specific packaging waste flow; resolve during dataset construction
  • Flow property / unit: Mass / kg
  • Amount rule: Measured packaging waste mass by material and destination
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per 1 kg of conforming finished reference product
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_test_outputs
  • Sources: eu-pef-2021-2279
Elementary flows

Record direct releases from testing, conditioning, cleaning, or packaging only when they occur and are supported by measurement or a documented calculation from collected records.

7. Allocation and Co-product Handling

rule_idApplies toRulesource_ids
alloc_avoidshared_manufacturing_processesAvoid allocation by separate metering, batch or line subdivision, or another defensible separation of processes and records directly attributable to the represented product.iso-14044-2006; eu-pef-2021-2279
alloc_physicalinseparable_shared_burdensWhen allocation cannot be avoided, use a documented causal physical relationship that reflects the driver of the shared input or output, such as machine time, test time, energy demand, or mass where mass is causally relevant.iso-14044-2006; eu-pef-2021-2279
alloc_other_relationshipno_defensible_physical_relationshipIf no relevant physical relationship can be demonstrated, use economic allocation or another justified relationship, disclose the data period and calculation, and report a sensitivity result for a materially different defensible method.iso-14044-2006; eu-pef-2021-2279
alloc_scrap_and_recyclingscrap_recycling_and_recoveryReport scrap and recovered material as visible output flows and state the upstream and end-of-life convention. Do not apply an avoided-burden credit inside this cradle-to-gate foreground package unless the declared governing methodology explicitly requires it.iec-63366-2025; iso-14044-2006

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_inhouse_materialsinhouse_component_manufactureraw materials, parts, and process materialspurchase, issue, return, stock, and composition recordspart_id; supplier; material; opening_stock; receipts; issues; returns; closing_stock; measured_mass; lot_idReconcile ERP or stores movements to production lots and verify mass by scales or supplier recordskgper lot with monthly reconciliationrepresentative continuous reporting period, normally at least 12 months, or justified shorter campaignevery included manufacturing site and in-house operationnet attributable consumption divided by accepted component output massBOM revision, supplier declaration, scale calibration, stock reconciliation, and restricted-substance documentation where applicable
cp_inhouse_energyinhouse_component_manufacturein-house manufacturing energymeter and production recordsmeter_id; carrier; opening_reading; closing_reading; submeter_scope; operating_time; allocation_driver; accepted_output_massRead dedicated submeters; if unavailable, reconcile complete site meters and apply the declared allocation rulekWh or MJmeter interval aggregated monthlysame period as production outputevery included site and energy carrierattributable consumption divided by accepted component output massmeter calibration or utility invoice, meter coverage map, and allocation evidence
cp_inhouse_outputsinhouse_component_manufactureaccepted output, wastes, and direct emissionsproduction, weighbridge, waste, discharge, and emissions recordsoutput_mass; reject_mass; waste_type; destination; recovery_status; concentration; discharge_volume; emission_periodMeasure accepted output and each waste; calculate direct emissions only from measured activity and concentration datakg; m3; measured concentration unitper lot or shipment; emissions at monitoring frequencysame period as production outputevery included in-house operationsum by flow and destination, then normalize to accepted output masscalibrated scales, waste manifests, laboratory reports, permits, and mass-balance reconciliation
cp_assembly_bomfinal_instrument_assemblyelectronic and mechanical BOM inputsproduct BOM and material issue recordsproduct_model; BOM_revision; part_id; supplier; quantity_per_unit; issued_quantity; returned_quantity; stock_change; unit_mass; included_battery_flagReconcile the product-specific BOM to actual issues, returns, substitutions, and stock changes; verify part masskg and item countper production lot with monthly reconciliationsame period as assembled outputevery final assembly sitenet attributable part mass divided by assembled output massapproved BOM, change notices, supplier declarations, measured part mass, and stock reconciliation
cp_assembly_energy_auxiliariesfinal_instrument_assemblyassembly energy and auxiliariesmeters, purchase, issue, and stock recordsmeter_id; carrier; reading; auxiliary_id; opening_stock; receipts; issues; closing_stock; allocation_driverSubmeter assembly energy and reconcile auxiliary consumption to production recordskWh or MJ; kgmeter interval and per lot, aggregated monthlysame period as assembled outputevery final assembly siteattributable energy or auxiliary quantity divided by assembled output massmeter evidence, invoices, calibrated scales, and allocation worksheet
cp_assembly_outputsfinal_instrument_assemblyassembled output, scrap, rejects, and reworkproduction and waste recordsassembled_output_mass; reject_mass; scrap_type; rework_entry; rework_exit; destinationMeasure unique accepted output and wastes; track rework loops without double counting outputkgper lotsame period as assembly inputsevery final assembly lineaccepted mass and waste mass by type normalized to accepted assembled outputcalibrated scales, lot genealogy, nonconformance records, and waste manifests
cp_test_inputscalibration_test_packagingassembled input, accessories, and packagingtest intake, packaging BOM, and issue recordsserial_or_lot; assembled_mass; rework_passes; accessory_id; packaging_material; quantity; unit_mass; included_in_reference_massLink unique instruments to test intake and reconcile included accessories and packaging to product-specific issue recordskg and item countper lot or serial batchsame period as released productevery calibration, test, and packaging siteunique input and included-material mass divided by conforming released product masstraceability record, packaging BOM, calibrated scale, and stock reconciliation
cp_test_energy_consumablescalibration_test_packagingcalibration, verification, and packaging energy and consumablesequipment meter, runtime, and consumable recordstest_station_id; test_type; meter_reading; runtime; conditioning_time; consumable_id; issued_quantity; allocation_driverUse dedicated test-station or area meters where available; otherwise use documented complete-meter allocationkWh or MJ; kgper test batch with monthly reconciliationsame period as released productevery included test and packaging operationattributable energy and consumables divided by conforming released product massmeter calibration, equipment log, utility invoice, and allocation worksheet
cp_final_output_qualitycalibration_test_packagingconforming finished product and conformance statusrelease, calibration, safety, EMC, and quality recordsmodel; serial_or_lot; measured_quantities; ranges; set_points; observed_results; accuracy_or_tolerance; uncertainty_if_reported; test_standard; equipment_id; equipment_calibration_status; pass_fail; released_massLink product release to the tests actually required and performed for the represented routekg and declared engineering unitseach serial unit or statistically justified lot, according to the applicable test plansame period as released productevery release site and represented product familysum conforming released mass; retain unaggregated conformance evidenceapproved test plan, calibrated equipment records, test results, nonconformance disposition, and release authorization
cp_test_outputscalibration_test_packagingtest rejects and packaging-process wastenonconformance and waste recordsreject_id; part_or_unit; measured_mass; cause; rework_status; final_disposition; waste_material; destinationTrack rejects through rework or final waste disposition and measure waste by materialkgper lot and waste shipmentsame period as released productevery test and packaging sitefinal waste leaving the rework loop divided by conforming released product massnonconformance report, calibrated scale, waste manifest, and rework genealogy

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
calc_reference_normalizationall foreground inventory rowsnormalized amount = attributable amount during the reporting period / conforming finished-product mass during the same period; convert the denominator to kg and scale to 1 kgattributable flow amount; conforming finished-product mass; unit conversion factoramount per 1 kg reference producteu-pef-2021-2279
calc_stock_adjusted_consumptionmaterials, components, packaging, and consumablesnet consumption = opening stock + receipts - closing stock - documented returns or transfers out; reconcile the result to lot issues and substitutionsopening stock; receipts; closing stock; returns; transfers; issue recordsstock-adjusted foreground consumptioneu-pef-2021-2279
calc_shared_meter_allocationenergy or auxiliaries without dedicated submeteringallocate the complete measured total using the first defensible allocation rule in Section 7 and document numerator, denominator, coverage, and reconciliation to the complete meter totaltotal meter consumption; selected physical or other allocation driver; represented outputattributable energy or auxiliary amountiso-14044-2006; eu-pef-2021-2279
calc_direct_emissionmeasured direct releasesreleased mass = measured concentration × measured discharge volume, with dimensional conversion and sampling-period coverage explicitly retainedconcentration; discharge volume; unit conversion; monitoring coveragesubstance mass releasedeu-pef-2021-2279
calc_reject_rateassembly and test rejectsreject rate = final reject mass leaving the rework loop / gross unique input mass; repeated rework passes do not increase gross unique inputfinal reject mass; gross unique input mass; rework genealogydisclosed reject fraction and waste mass per kg reference producteu-pef-2021-2279

Data Quality Requirements

requirement_idApplies toRequirementEvidence
dq_product_identityreference productDemonstrate that the represented models measure or check one or more of voltage, current, resistance, or power, lack a recording device, and are not electricity production or supply meters or excluded oscilloscopes/oscillographs.Product specification, approved BOM, user documentation, nameplate, and classification review against unsd-cpc-3-0
dq_temporal_consistencyall foreground recordsInputs, outputs, meters, stock movements, and released-product mass must cover the same representative period; justify campaigns shorter than 12 months and disclose seasonality or production-ramp effects.Dated production, stock, meter, and shipment records
dq_technological_geographical_representativenessprocesses and upstream datasetsMatch technology, component state, electricity supply, treatment route, geography, and production period to the represented route; disclose proxies and materially different sites or product families.Dataset metadata, supplier/site mapping, and representativeness assessment following eu-pef-2021-2279
dq_bom_and_mass_reconciliationproduct and packaging materialsReconcile the current product-specific BOM, substitutions, stock-adjusted consumption, accepted output, rejects, wastes, and included packaging/accessory convention; explain unreconciled mass.BOM revision, stock reconciliation, scale records, output records, and mass-balance worksheet
dq_measurement_traceabilityproduct calibration and conformance testsRetain test method, equipment identifier, calibration status, set points, results, tolerance or uncertainty, and pass/fail status for tests actually performed; identify applicable safety and EMC standards without claiming unperformed tests.Test plan and results, equipment calibration records, and applicable iec-61010-1-2010-amd1-2016 and iec-61326-1-2020 evidence
dq_substance_documentationmaterials and componentsRetain supplier and manufacturer documentation used to assess restricted substances and clearly distinguish declarations, analytical results, and unresolved evidence gaps.Supplier declarations and technical documentation structured according to iec-63000-2016-amd1-2022

9. Validation Rules

rule_idApplies toRulesource_ids
val_identity_scopereference_product_identityReject the package if the product includes a recording device, is an electricity production or supply meter, is a cathode-ray oscilloscope or oscillograph, or otherwise falls outside the declared product boundary.unsd-cpc-3-0
val_reference_flowreference_flow_consistencyRequire the exact reference product flow UUID, Mass flow-property UUID, Units of mass unit-group UUID, kg reference unit, exactly 1 kg normalized output, and all required qualifiers.
val_process_coverageforeground_process_completenessRequire final assembly and calibration/verification/release/packaging records, and require in-house component manufacture whenever the declared site performs it; every included process must have inputs, outputs, waste disposition, and a linked collection protocol.iec-63366-2025; eu-pef-2021-2279
val_bom_energy_wasteinventory_completenessRequire a product-specific BOM and packaging/accessory convention, energy and auxiliary records for each included process, final product output, rejects and wastes, and direct emissions when they occur; unresolved upstream datasets must be disclosed as data gaps.eu-pef-2021-2279
val_quality_releaseproduct_conformanceRequire release evidence for the declared measurement functions and applicable calibration, safety, and EMC test plan; standards cited in metadata do not count as evidence that a test was performed.iec-61010-1-2010-amd1-2016; iec-61326-1-2020
val_allocation_disclosureshared_burdensRequire every shared burden to identify the allocation decision, driver, numerator, denominator, data period, source records, reconciliation to the complete total, and justification for not applying an earlier hierarchy step.iso-14044-2006; eu-pef-2021-2279
val_no_unsupported_valuesquantitative_evidenceReject invented category-default quantities, undocumented proxy UUIDs, or values copied from a different product/process. Values must arise from the declared collection/calculation protocol or cited non-default evidence.iso-14044-2006; eu-pef-2021-2279

10. Published Dataset Profile

FieldValue
dataset_roleProduct-specific cradle-to-gate foreground manufacturing dataset normalized to 1 kg of conforming finished non-recording electrical measuring instrument
downstream_useSecondary dataset and background dataset for process or lifecyclemodel construction when product identity, route, geography, period, and included-product convention match
allowed_useModelling the manufacture of covered instruments; supplier or site comparisons with harmonized scope and qualifiers; incorporation into broader product systems with transparent upstream and downstream extensions
excluded_useA category-average claim without representative sampling; use-stage service comparison without declared lifetime and performance; modelling excluded recording instruments, supply meters, oscilloscopes, oscillographs, standalone parts, or services; regulatory conformity claims based solely on this LCA dataset
required_metadatacanonical PCR id; product model or family; measured quantities, ranges, and accuracy; recording-device absence; safety category and rated voltage where applicable; geography; technology and in-house/purchased route; reporting period; product, accessories, battery, manual, and packaging mass convention; upstream datasets; allocation and cut-off decisions; test-plan coverage
required_quality_disclosureForeground share and primary-data coverage; temporal, geographical, and technological representativeness; BOM and mass reconciliation; meter and allocation coverage; test and calibration evidence; proxy and upstream data gaps; reject/rework treatment; exclusions and uncertainty limitations
update_triggerProduct or BOM revision; added recording functionality; changed principal measured quantity or accuracy/safety category; changed site, technology, supply mix, packaging, included accessories or batteries; material supplier substitution; changed test plan or applicable standard; reporting data older than the declared validity period; material unresolved data gap closed

11. Data Sources

Source idTypeReferenceUsed for
unsd-cpc-3-0Dataset (dataset)United Nations Statistics Division, Central Product Classification Version 3.0, structure and explanatory-note resources, including subclass 48243, https://unstats.un.org/unsd/classifications/econ (retrieved 2026-08-09)Product-category inclusion and exclusion boundary
iec-63366-2025Standard (standard)IEC 63366:2025, Product category rules for life cycle assessment of electrical and electronic products and systems, https://webstore.iec.ch/en/publication/67691 (retrieved 2026-08-09)Electrical/electronic-product PCR framework, recorded complementary specifications, system-boundary and reporting context
iso-14044-2006Standard (standard)ISO 14044:2006 with Amendments 1:2017 and 2:2020, Environmental management — Life cycle assessment — Requirements and guidelines, https://www.iso.org/standard/38498.html (retrieved 2026-08-09)LCI completeness, allocation hierarchy, reporting, interpretation, and limitations
eu-pef-2021-2279Official guidance (official_guidance)European Commission Recommendation (EU) 2021/2279 and corrigendum, Product Environmental Footprint Method, http://data.europa.eu/eli/reco/2021/2279/oj (retrieved 2026-08-09)Functional-unit/reference-flow structure, company-specific BOM and manufacturing data, process inputs and outputs, data quality, allocation, calculation, and cut-off disclosure
iec-61010-1-2010-amd1-2016Standard (standard)IEC 61010-1:2010+AMD1:2016, Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 1: General requirements, https://webstore.iec.ch/en/publication/4279 (retrieved 2026-08-09)Applicability of safety requirements and product-specific safety-test evidence for electrical test and measurement equipment
iec-61326-1-2020Standard (standard)IEC 61326-1:2020, Electrical equipment for measurement, control and laboratory use — EMC requirements — Part 1: General requirements, https://webstore.iec.ch/en/publication/62793 (retrieved 2026-08-09)Applicability of emissions and immunity verification and retention of route-specific EMC test evidence
iec-63000-2016-amd1-2022Standard (standard)IEC 63000:2016+AMD1:2022, Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances, https://webstore.iec.ch/en/publication/25985 (retrieved 2026-08-09)Supplier and manufacturer restricted-substance technical-documentation evidence

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 5
Rule IDApplies toRuleSource IDs
sb_foreground_manufacturingforeground_system_boundaryInclude all directly controlled and attributable in-house component manufacture, electromechanical assembly, firmware loading when part of manufacture, calibration, functional verification, applicable safety and EMC tests, quality control, rework, cleaning, and packaging through the finished-product factory gate.iec-63366-2025, eu-pef-2021-2279
sb_purchased_inputspurchased_input_boundaryRecord the full product-specific bill of materials and packaging, purchased subassemblies, energy, auxiliaries, intra-site handling, and waste/treatment outputs; connect each purchased input to an upstream dataset rather than omitting it from the foreground package.eu-pef-2021-2279
sb_compliance_evidenceproduct_conformance_boundaryInclude the activity data for tests actually performed for the represented product route and retain product safety, EMC, calibration, and restricted-substance documentation; a cited standard does not substitute for the product's test or supplier records.iec-61010-1-2010-amd1-2016, iec-61326-1-2020, iec-63000-2016-amd1-2022
sb_no_silent_cutoffforeground_cutoffDo not silently omit known production inputs, outputs, or process stages. Any exclusion must identify the omitted flow or stage, the reason and materiality basis, the governing study method, and the expected effect on completeness.iso-14044-2006, eu-pef-2021-2279
sb_extended_stagesdownstream_extensionKeep distribution, use, maintenance, and end-of-life outside the default foreground package; if added for a specific study, model and disclose them as an explicit boundary extension without changing the canonical cradle-to-gate reference-flow identity.iec-63366-2025, iso-14044-2006
Allocation rules · 4
Rule IDApplies toRuleSource IDs
alloc_avoidshared_manufacturing_processesAvoid allocation by separate metering, batch or line subdivision, or another defensible separation of processes and records directly attributable to the represented product.iso-14044-2006, eu-pef-2021-2279
alloc_physicalinseparable_shared_burdensWhen allocation cannot be avoided, use a documented causal physical relationship that reflects the driver of the shared input or output, such as machine time, test time, energy demand, or mass where mass is causally relevant.iso-14044-2006, eu-pef-2021-2279
alloc_other_relationshipno_defensible_physical_relationshipIf no relevant physical relationship can be demonstrated, use economic allocation or another justified relationship, disclose the data period and calculation, and report a sensitivity result for a materially different defensible method.iso-14044-2006, eu-pef-2021-2279
alloc_scrap_and_recyclingscrap_recycling_and_recoveryReport scrap and recovered material as visible output flows and state the upstream and end-of-life convention. Do not apply an avoided-burden credit inside this cradle-to-gate foreground package unless the declared governing methodology explicitly requires it.iec-63366-2025, iso-14044-2006
Validation rules · 7
Rule IDApplies toRuleSource IDs
val_identity_scopereference_product_identityReject the package if the product includes a recording device, is an electricity production or supply meter, is a cathode-ray oscilloscope or oscillograph, or otherwise falls outside the declared product boundary.unsd-cpc-3-0
val_reference_flowreference_flow_consistencyRequire the exact reference product flow UUID, Mass flow-property UUID, Units of mass unit-group UUID, kg reference unit, exactly 1 kg normalized output, and all required qualifiers.
val_process_coverageforeground_process_completenessRequire final assembly and calibration/verification/release/packaging records, and require in-house component manufacture whenever the declared site performs it; every included process must have inputs, outputs, waste disposition, and a linked collection protocol.iec-63366-2025, eu-pef-2021-2279
val_bom_energy_wasteinventory_completenessRequire a product-specific BOM and packaging/accessory convention, energy and auxiliary records for each included process, final product output, rejects and wastes, and direct emissions when they occur; unresolved upstream datasets must be disclosed as data gaps.eu-pef-2021-2279
val_quality_releaseproduct_conformanceRequire release evidence for the declared measurement functions and applicable calibration, safety, and EMC test plan; standards cited in metadata do not count as evidence that a test was performed.iec-61010-1-2010-amd1-2016, iec-61326-1-2020
val_allocation_disclosureshared_burdensRequire every shared burden to identify the allocation decision, driver, numerator, denominator, data period, source records, reconciliation to the complete total, and justification for not applying an earlier hierarchy step.iso-14044-2006, eu-pef-2021-2279
val_no_unsupported_valuesquantitative_evidenceReject invented category-default quantities, undocumented proxy UUIDs, or values copied from a different product/process. Values must arise from the declared collection/calculation protocol or cited non-default evidence.iso-14044-2006, eu-pef-2021-2279
Processes and inputs/outputs · 3
Process IDProcess nameInput flowsOutput flows
inhouse_component_manufactureIn-house component and subassembly manufacture23
final_instrument_assemblyFinal instrument assembly and configuration32
calibration_test_packagingCalibration, verification, release, and packaging33

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page

1. Scope and Applicability2. Product Category Identity3. Reference Flow4. Measurement and Unit Rules5. System BoundaryBoundary Abstraction6. Process Inventory StructureProcess MapProcess: In-house component and subassembly manufacture (inhouse_component_manufacture)InputsProduct flowsRaw materials, parts, and process materials for in-house manufacture (inhouse_material_inputs)Energy supplied to in-house manufacture (inhouse_energy)Waste flowsElementary flowsOutputsProduct flowsAccepted in-house components and subassemblies (inhouse_component_output)Waste flowsIn-house manufacturing scrap, rejects, and treatment residues (inhouse_waste_outputs)Elementary flowsDirect emissions from in-house component manufacture (inhouse_direct_emissions)Process: Final instrument assembly and configuration (final_instrument_assembly)InputsProduct flowsElectronic, sensing, and electromechanical bill-of-material inputs (assembly_electronic_inputs)Housings, mechanical parts, fasteners, and labels (assembly_mechanical_inputs)Assembly energy and directly consumed auxiliaries (assembly_energy_auxiliaries)Waste flowsElementary flowsOutputsProduct flowsAssembled instrument awaiting calibration and release (assembled_instrument_output)Waste flowsAssembly scrap, rejects, and replaced parts (assembly_waste_outputs)Elementary flowsProcess: Calibration, verification, release, and packaging (calibration_test_packaging)InputsProduct flowsAssembled instrument input (test_assembled_input)Test, calibration, and packaging energy and consumables (test_energy_consumables)Sales packaging and included accessories (packaging_accessory_inputs)Waste flowsElementary flowsOutputsProduct flowsConforming finished non-recording electrical measuring instrument (reference_product_output)Waste flowsFailed units, replaced parts, and test rejects (test_reject_outputs)Packaging-process waste (packaging_waste_outputs)Elementary flows7. Allocation and Co-product Handling8. Foreground Data Collection, Calculation, and Quality RulesData Collection ProtocolsCalculation RulesData Quality Requirements9. Validation Rules10. Published Dataset Profile11. Data Sources