TianGong PCR

Daily radio channel programme line-up

Lifecycle status
Candidate
Content maturity
Authored methodology
Current version
0.1.0Last updated
Readiness
Review required

Methodology and translation states come from the source record; publishing this website does not change their review status.

Content languages

zh-CN · Aligned
Status, classification and source details

Readiness

  • Warnings methodology_not_reviewed Authored methodology is candidate guidance and still requires methodology review.

Classification mapping

CPC 3.0:84621 · exact

Source

1. Scope and Applicability

Applies to a station's complete daily assembly of programmes, live broadcasts and continuity content handed to another distributor. Covers recorded, live and mixed line-ups; one short episode cannot substitute for the daily assembly. Official classification distinguishes this object from original broadcast assets and broadcasting services (unsd-cpc3-2025, p.444). Delivery comprises actual audio or mutually accepted programme references and live handoff interfaces, schedule and technical metadata; abstract scheduling consultancy alone is outside scope.

Count one complete daily delivery, not mass, revenue, licence price or audience. Stratify language, advertising variants, genres, airtime, repeat-content share and handoff specification; technical differences do not automatically establish environmental superiority.

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.business-and-production-services.telecommunications-broadcasting-and-information-supply-services.daily-radio-channel-programme-lineup
classification_refsCPC 3.0 84621 — Radio channel programmes
covered_productsComplete recorded, live and mixed station daily radio line-ups for distribution by others
excluded_productsIndividual broadcast original masters; sound-recording originals; listener audio downloads or streaming; transmission and subscriber distribution services; equipment manufacture; scheduling consultancy
representative_productAccepted daily radio channel programme line-up
production_routeProgramme receipt and checking → scheduling and continuity → conditional live contribution → delivery checking and handoff
market_stateComplete accepted daily line-up identified by station, date, version and recipient

3. Reference Flow

FieldValue
WhatProvide another distributor with the assembled programming of one complete station broadcast day
How much1 complete daily line-up containing all scheduled programming
How wellOrder, timing, available asset references, live interfaces, audio and metadata meet the recipient’s recorded acceptance specification
How long or cycleOne station broadcast day with declared timestamps and time zone; record actual airtime without assuming 24 hours; disclose repeats and retention separately
reference_flow_linkreference_product_daily_lineup
FieldValue
Reference amount1
Reference product flowAccepted daily radio channel programme line-up
Reference flow propertyNumber of items 01846770-4cfe-4a25-8ad9-919d8d378345
Reference unit groupUnits of items 5beb6eed-33a9-47b8-9ede-1dfe8f679159
Reference unititem
Required qualifiersstation and editorial service; date, time zone, timestamps and actual airtime; language; line-up version and asset list; recorded/live share; advertising variant; format, sample rate, channels and loudness policy; rights and reuse scope; handoff point and recipient acceptance; production/distribution separation; geography and voltage; retention and shared allocation; equipment and original-asset boundary

item denotes the same single-count unit as public Item(s). Only a complete accepted daily line-up is one item; retransmitting the same version does not add another line-up. Required qualifiers belong in the data package; rights define permissible delivery and are not physical quality or mass.

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
reference_countreference productNumber of items 01846770-4cfe-4a25-8ad9-919d8d378345itemUse cp_delivery to collect identity and timing of one complete accepted daily line-up; every inventory row is per declared reference flow. Actual duration qualifies delivery and is not converted to mass.
electricity_unitingest_electricity, schedule_electricity, live_electricity, handoff_electricityNet calorific value 93a60a56-a3c8-11da-a746-0800200c9a66MJPreserve the public primary property and energy unit group 93a60a57-a3c8-11da-a746-0800200c9a66; multiply measured meter kWh by 3.6 to obtain MJ. GB, CPU-hours and audio seconds are not energy.
service_countsource_programme_master, hosted_playout_day, contribution_link_dayNumber of items 01846770-4cfe-4a25-8ad9-919d8d378345itemSeparately define one approved audio programme master, one specified daily hosted playout package and one daily contribution-link delivery package. Verify against contracts and activity records; price and data traffic alone cannot establish the amount.

5. System Boundary

Boundary Abstraction

FieldValue
declared_starting_conditionIdentified programme masters with usage rights or actual live contributions available at the compiler’s receiving interface
starting_condition_roleForeground production input; new original creation is a separate upstream module even when supplied internally
product_classification_scopeComplete daily radio channel programme assemblies for distribution by others
recursive_input_ruleFor re-editing an existing line-up, count its actual input and incremental assembly once without recursively rebuilding the original day
upstream_dataset_requirementRepresentative datasets for source content, purchased electricity, outsourced hosting and contribution links; declare whether equipment and facility manufacture is included
disclosureForeground receipt/checking through complete daily handoff; missing upstream and capital equipment prevents a complete cradle-to-gate claim; disclose measured energy, source-asset boundaries, allocation, storage, unmeasured activities and exclusions
rule_idapplies_torulesource_ids
sb_deliverydaily assemblyInclude receipt, asset checking, scheduling, continuity, required storage, actual live mixing, acceptance and handoff to the distributor, including failed handoff retries and actual rework energy.unsd-cpc3-2025; ebu-radio-workflow-2023
sb_separate_distributiondownstreamModel FM/DAB transmission, listener-network distribution, playback and terminal manufacture beyond the handoff separately; split combined operations using recorded interfaces.unsd-cpc3-2025; ebu-radio-workflow-2023
sb_actual_resourcesfacilities and supporting activitiesInclude measured or explainably attributable workstation, server, playout, storage and cooling electricity and production-support lighting. Equipment/facility manufacture, commuting and long-term archives are excluded by default and disclosed. Actual attributable on-site combustion, refrigerant leakage, consumables or equipment replacement require separately collected atomic extensions; no emissions are presumed without evidence.ebu-radio-workflow-2023

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
programme_ingestProgramme receipt and checkingrequiredAll deliveries; file/live receipt follows actual routeforeground production1 item complete daily line-up
lineup_assemblyDaily scheduling and continuityrequiredAll approved programmes and continuityforeground production1 item complete daily line-up
live_contributionLive contribution production and mixingconditionalOnly actual foreground live operationforeground production1 item complete daily line-up
delivery_handoffAcceptance, storage and handoffrequiredComplete daily assembly handed to othersforeground production1 item complete daily line-up

Process: Programme receipt and checking (programme_ingest)

Inputs

Product flows
Approved audio programme master (source_programme_master)

Include when recorded content is used; record each concrete master and version separately, not rights fees as production burden. Internally produced live content is not also a purchased master.

  • Selected flow: Approved audio programme master
  • Flow property / unit: Number of items / item
  • Amount rule: Attributed shares of actual programme masters; per declared reference flow
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per declared reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_assets
  • Sources: ebu-radio-workflow-2023; unsd-cpc3-2025
Alternating current (ingest_electricity)

Record measured electricity for this operation and attributable support equipment under cp_energy. This UUID applies only to CN grid-average consumption mix delivered to the user at <1 kV; other geography or voltage requires separately verified matching identity.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Measured attributable operation kWh converted to MJ under electricity_unit; per declared reference flow
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per declared reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_energy
  • Sources: ebu-radio-workflow-2023; unsd-cpc3-2025

Process: Daily scheduling and continuity (lineup_assembly)

Inputs

Product flows
Alternating current (schedule_electricity)

Record measured electricity for this operation and attributable support equipment under cp_energy. This UUID applies only to CN grid-average consumption mix delivered to the user at <1 kV; other geography or voltage requires separately verified matching identity.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Measured attributable operation kWh converted to MJ under electricity_unit; per declared reference flow
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per declared reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_energy
  • Sources: ebu-radio-workflow-2023; unsd-cpc3-2025

Process: Live contribution production and mixing (live_contribution)

Inputs

Product flows
Alternating current (live_electricity)

Record measured electricity for this operation and attributable support equipment under cp_energy. This UUID applies only to CN grid-average consumption mix delivered to the user at <1 kV; other geography or voltage requires separately verified matching identity.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Measured attributable operation kWh converted to MJ under electricity_unit; per declared reference flow
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per declared reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_energy
  • Sources: ebu-radio-workflow-2023; unsd-cpc3-2025

This operation handles actual live continuity and mixing. Complex field recording, reporting, travel or event production belongs in a separate original-contribution module with linked inventory; live content is not presumed to consist entirely of workstation audio.

Process: Acceptance, storage and handoff (delivery_handoff)

Inputs

Product flows
Alternating current (handoff_electricity)

Record measured electricity for this operation and attributable support equipment under cp_energy. This UUID applies only to CN grid-average consumption mix delivered to the user at <1 kV; other geography or voltage requires separately verified matching identity.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value / MJ
  • Amount rule: Measured attributable operation kWh converted to MJ under electricity_unit; per declared reference flow
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per declared reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_energy
  • Sources: ebu-radio-workflow-2023; unsd-cpc3-2025
Daily hosted playout delivery package (hosted_playout_day)

Include one specified service only for outsourced storage and playout; the contract identifies audio version, duration, redundancy and system boundary. Do not add local electricity, cooling or hardware burdens already included by the supplier; internal operation does not use this row.

  • Selected flow: Daily hosted playout delivery package
  • Flow property / unit: Number of items / item
  • Amount rule: Record attributed count of actually delivered contractual packages; per declared reference flow
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per declared reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_services
  • Sources: ebu-radio-workflow-2023; unsd-cpc3-2025

Include only an actual outsourced contribution link carrying line-up or live signal to the distributor interface; this is one specified link service excluding the audience network. Supplier primary activity evidence is required; transmitted GB is not directly converted to kWh.

  • Selected flow: Daily contribution-link handoff package
  • Flow property / unit: Number of items / item
  • Amount rule: Record attributed count of actually delivered contractual link packages; per declared reference flow
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per declared reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_services
  • Sources: ebu-radio-workflow-2023; unsd-cpc3-2025

Outputs

Product flows
Accepted daily radio channel programme line-up (reference_product_daily_lineup)

Unique output of the complete accepted daily line-up. Retain the schedule, asset references, live interfaces and acceptance record; delivery retries do not add output.

  • Selected flow: Accepted daily radio channel programme line-up
  • Flow property / unit: Number of items / item
  • Amount rule: 1 item
  • Value mode: Fixed value (fixed_value)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per declared reference flow
  • Basis kind: Reference flow (reference_flow)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_delivery
  • Sources: ebu-radio-workflow-2023; unsd-cpc3-2025

No direct elementary emission or physical waste is presumed in this inventory: deleting an audio file is not a material waste flow, and power-station emissions belong upstream of purchased electricity. Actual on-site combustion, refrigerant losses or discarded consumables must be separately added and verified under sb_actual_resources when constructing a concrete data package; a manufacturing emission inventory is not imposed without evidence.

7. Allocation and Co-product Handling

rule_idapplies_torulesource_ids
alloc_meteringshared equipmentPrefer separate meters and tasks; attribute shared-meter energy using measured task power and run time, not sale price or audience. cp_energy records active, idle, retained storage, cooling and other users; allocation must reconcile the measured total. Allocate idle energy using recorded reserved-use time and report sensitivity.
alloc_original_reusesource_programme_masterKeep original-creation inventory separately. cp_assets defines the evidenced, non-overlapping reuse set and daily attribution weights summing to one; equivalent complete uses may share equally across evidenced uses without assumed count or lifetime. Excerpt attribution requires evidence connecting duration to creation effort; unproven attribution remains review. Rights transactions do not eliminate content burdens, nor justify adding full creation cost on every play.
alloc_variantsline-up variants and retriesSeparate incremental tasks for language, advertising and regional variants with independently delivered outputs. Allocate shared assembly by documented actual task relationships; master, schedule and acceptance receipt are not three co-products. Attribute failed retries to the delivered line-up.

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_deliverydelivery_handoffreference productacceptance recordstation; schedule version; date; time zone; start/end; actual airtime; asset completeness; recipient; acceptanceReconcile each daily schedule with asset list, checksums and handoff logs; count only complete accepted versionsitemeach complete handoffcomplete assembly and handoff periodcompiler and handoff interfaceper declared reference flowrecipient acceptance and completeness records
cp_energyprogramme_ingest; lineup_assembly; live_contribution; delivery_handoffelectricitymeter and job recordmeter start/end kWh; equipment; task; active/idle time; geography; voltage; cooling; retention; shared weightsUse verified meters and measured equipment power with task logs; remove overlaps and include rework and attributable supporting energykWheach operation or time intervalassembly preparation, handoff and required retention perioddeclared sites and internally operated equipmentper declared reference flowcalibration, complete meter balance and shared-task ledger
cp_assetsprogramme_ingestsource programmeasset and upstream inventory recordeach master ID/version; original-creation inventory; reuse set; daily attribution share; duration; rightsReconcile actual programme asset list with separate original inventory; retain evidence for complete and excerpt useitemeach master and line-upcreation and reuse period relevant to the line-upactual source creator and compilerper declared reference floworiginal inventory and non-duplicate attribution audit
cp_servicesdelivery_handoffexternal servicecontract delivery and supplier primary dataspecific package ID; service type; schedule; duration; capacity; traffic; supplier energy; hardware boundary; shared attribution; receiptSeparately verify actual hosting and link packages against receipts and supplier inventories; traffic checks capacity without default energy conversionitemeach contractual packagecomplete contracted service perioddeclared actual suppliersper declared reference flowservice boundary, supplier primary records and non-duplicate electricity ledger

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
energy_conversioningest_electricity, schedule_electricity, live_electricity, handoff_electricityPer declared reference flow, multiply measured attributable kWh by 3.6 to obtain MJ; four operation amounts must not overlap and their sum reconciles attributable meter totals.cp_energyMJ per declared reference flow
asset_attributionsource_programme_masterPer declared reference flow, record each concrete master’s evidenced attribution share and link its separate creation inventory; weights over the complete reuse set must sum to one, retaining excerpt-relationship evidence.cp_assetsmaster shares per declared reference flow
service_attributionhosted_playout_day, contribution_link_dayPer declared reference flow, use actual package counts and evidenced shared fractions; link matching supplier inventories without a default GB-to-energy factor.cp_servicescontract package shares per declared reference flow

Data Quality Requirements

requirement_idApplies toRequirementEvidence
dq_identityreference_product_daily_lineupComplete identifiable daily delivery with actual duration, recorded/live mix, version and reuse rights; an episode cannot stand for the day.cp_delivery; unsd-cpc3-2025
dq_technicalaudio and handoffRecord recipient acceptance of format, integrity and loudness policy. Verify declared EBU strategy against its declared edition only when adopted, not as a universal mandate.cp_delivery; ebu-radio-workflow-2023
dq_representativeall inventory rowsOne day represents that case; a channel-representative value requires declared-period coverage of weekdays, weekends, repeats and live differences with daily distributions. No default energy is supplied.cp_delivery; cp_energy
dq_missingall inventory rowsMissing meters, absent supplier inventories, unproven reuse shares and unresolved identities remain explicit gaps, not zero.cp_assets; cp_services; cp_energy

9. Validation Rules

rule_idapplies_torulesource_ids
vr_referencereference productConfirm one complete daily output, count unit, actual times, acceptance and every qualifier; other delivery objects are inapplicable.unsd-cpc3-2025
vr_energyelectricity rowsCheck meter totals and attribution, 3.6 conversion, voltage and geography; do not recount electricity already included in supplier services.
vr_originalssource assets and servicesCheck original inventories and reuse weights, interface boundaries, actual contract-package units and primary activity records; counting cannot replace supplier physical inventory. Unproven shares require review.
vr_completenesswhole datasetCheck every required and actual conditional activity. Expose gaps and default exclusions; absent upstream or equipment manufacture prevents a complete lifecycle claim. Add elementary flows only for evidenced direct occurrences with verified identity and compartment, not inferred site emissions from grid generation.ebu-radio-workflow-2023

10. Published Dataset Profile

FieldValue
dataset_roleforeground production dataset for a complete daily channel line-up
downstream_usesecondary_dataset; background_dataset
allowed_usechannel-delivery modelling with matching boundary and technical configuration; linking to separate distribution/playback modules
excluded_useproxy for one original work, download, listener-hour, transmission coverage, software or hardware manufacture; complete lifecycle claims without linked evidence
required_metadataall reference qualifiers, process coverage, geography, voltage, measured supply, source and service datasets, reuse sets, attribution methods, conditional activities and handoff acceptance
required_quality_disclosuremeter uncertainty, sampling representativeness, missing supplier evidence, unresolved identities, equipment boundary, original-reuse and idle-allocation sensitivity
update_triggerchanges in schedule/version, recorded/live mix, supplier, system/electricity conditions, retention, original reuse set or handoff specification

11. Data Sources

Source idTypeReferenceUsed for
unsd-cpc3-2025official_guidanceUnited Nations Statistics Division, CPC Version 3.0 Explanatory Notes, 30 June 2025, PDF/printed p.444. https://unstats.un.org/unsd/classifications/Econ/Download/In%20Text/CPC_Ver_3.0_Exp_Notes_30Jun2025.pdfDaily assembly versus original-asset and broadcast-service boundaries; no measurement coefficients
ebu-radio-workflow-2023official_guidanceEuropean Broadcasting Union, Tech 3401, November 2023, §2 Figure 4 p.7; §§3–4 pp.8–10. https://tech.ebu.ch/docs/tech/tech3401.pdfProduction/distribution interfaces and loudness metadata; not energy or universal audio-threshold evidence

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 3
Rule IDApplies toRuleSource IDs
sb_deliverydaily assemblyInclude receipt, asset checking, scheduling, continuity, required storage, actual live mixing, acceptance and handoff to the distributor, including failed handoff retries and actual rework energy.unsd-cpc3-2025, ebu-radio-workflow-2023
sb_separate_distributiondownstreamModel FM/DAB transmission, listener-network distribution, playback and terminal manufacture beyond the handoff separately; split combined operations using recorded interfaces.unsd-cpc3-2025, ebu-radio-workflow-2023
sb_actual_resourcesfacilities and supporting activitiesInclude measured or explainably attributable workstation, server, playout, storage and cooling electricity and production-support lighting. Equipment/facility manufacture, commuting and long-term archives are excluded by default and disclosed. Actual attributable on-site combustion, refrigerant leakage, consumables or equipment replacement require separately collected atomic extensions; no emissions are presumed without evidence.ebu-radio-workflow-2023
Allocation rules · 3
Rule IDApplies toRuleSource IDs
alloc_meteringshared equipmentPrefer separate meters and tasks; attribute shared-meter energy using measured task power and run time, not sale price or audience. cp_energy records active, idle, retained storage, cooling and other users; allocation must reconcile the measured total. Allocate idle energy using recorded reserved-use time and report sensitivity.
alloc_original_reusesource_programme_masterKeep original-creation inventory separately. cp_assets defines the evidenced, non-overlapping reuse set and daily attribution weights summing to one; equivalent complete uses may share equally across evidenced uses without assumed count or lifetime. Excerpt attribution requires evidence connecting duration to creation effort; unproven attribution remains review. Rights transactions do not eliminate content burdens, nor justify adding full creation cost on every play.
alloc_variantsline-up variants and retriesSeparate incremental tasks for language, advertising and regional variants with independently delivered outputs. Allocate shared assembly by documented actual task relationships; master, schedule and acceptance receipt are not three co-products. Attribute failed retries to the delivered line-up.
Validation rules · 4
Rule IDApplies toRuleSource IDs
vr_referencereference productConfirm one complete daily output, count unit, actual times, acceptance and every qualifier; other delivery objects are inapplicable.unsd-cpc3-2025
vr_energyelectricity rowsCheck meter totals and attribution, 3.6 conversion, voltage and geography; do not recount electricity already included in supplier services.
vr_originalssource assets and servicesCheck original inventories and reuse weights, interface boundaries, actual contract-package units and primary activity records; counting cannot replace supplier physical inventory. Unproven shares require review.
vr_completenesswhole datasetCheck every required and actual conditional activity. Expose gaps and default exclusions; absent upstream or equipment manufacture prevents a complete lifecycle claim. Add elementary flows only for evidenced direct occurrences with verified identity and compartment, not inferred site emissions from grid generation.ebu-radio-workflow-2023
Processes and inputs/outputs · 4
Process IDProcess nameInput flowsOutput flows
programme_ingestProgramme receipt and checking20
lineup_assemblyDaily scheduling and continuity10
live_contributionLive contribution production and mixing10
delivery_handoffAcceptance, storage and handoff31

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page