1. Scope and Applicability

This PCR covers own-account original industrial product, aesthetic and graphic design concepts, produced as identifiable intellectual-property assets for intended sale or licensing (un-cpc3-design-originals). Cover their actual creation cycle, including unsuccessful iterations, physical mockups when used, and the versioned original package. The asset is the design concept; paper, files and prototypes are its carriers or development aids. No file format, registration, revenue or license count proves originality or environmental equivalence.

Exclude commissioned design services as the final product, scientific research originals, mineral exploration results, executable software originals, standalone data, brands/franchises, literary/artistic originals, digital copies/downloads and broadcast programmes. Graphic design intended as a reusable design concept differs from a standalone artistic work. Embedded source files and data integral to the design are part of the package; separate software/data products require their own boundary. Mixed scientific R&D and design projects require a deliverable ledger separating knowledge creation from design-concept development; do not duplicate their shared work.

2. Product Category Identity

FieldValue
canonical_pcr_idpcr.business-and-production-services.design-assets.own-account-design-original
classification_refsCPC 3.0 83920
covered_productsOwn-account original industrial, aesthetic and graphic design concept assets
excluded_productsCommissioned services; research, exploration, software, data, artistic, brand, download and broadcast products
representative_productOwn-account design original package
production_routeActual brief → concepts and iterations → applicable mockups/proofs → verification → versioned original completion; route and resources specified
market_stateComplete original asset ready for intended sale/licensing; rights and reuse restrictions actually documented

3. Reference Flow

FieldValue
WhatCreate one identified reusable original design concept asset
How muchOne complete declared original package of one version
How wellDeclare design objective, product/application, technical/aesthetic/graphic specification, content inventory, originality basis, verification results, unresolved limitations and rights; no safety or legal approval inferred
How long or cycleOne actual creation cycle through recorded completion and initial handoff cutoff; no assumed useful life or license duration
reference_flow_linkreference_product_original
FieldValue
Reference amount1
Reference product flowOwn-account design original package
Reference flow propertyNumber of items 01846770-4cfe-4a25-8ad9-919d8d378345
Reference unit groupUnits of items 5beb6eed-33a9-47b8-9ede-1dfe8f679159
Reference unititem
Required qualifiersoriginal/project ID; version and package contents; own-account status; design/application type and objective; intended sale/licensing; actual production route; completeness and verification; quality limitations; rights/reuse restrictions; creation dates and cutoff; geography/voltage; shared resource and inherited-original allocation; upstream completeness

Required qualifiers must accompany the dataset. One package count is a production reference, not a claim that unrelated designs have equivalent utility. Downloads, licenses, file count, bytes, users and prices are not conversions to this reference.

4. Measurement and Unit Rules

rule_idApplies toRequired propertyRequired unitRule
reference_countreference productNumber of items 01846770-4cfe-4a25-8ad9-919d8d378345itemitem is the factor-1 display alias of public Item(s); cp_original records one complete version. No physical mass is imputed to the design.
energy_unitelectricity rowsNet calorific value 93a60a56-a3c8-11da-a746-0800200c9a66MJcp_energy collects measured kWh; 1 kWh = 3.6 MJ preserves the identical supply interface. Traffic volume or reservation time alone is not measured electricity.
same_referenceall inventory rowsOriginal package countitemInventory amounts and collection aggregates are per declared reference flow. Retain each exchange numerator in its stated unit; do not convert the original into kg or the network into kWh.

Mass 93a60a56-a3c8-11da-a746-0800200b9a66 references kg unit group 93a60a57-a4c8-11da-a746-0800200c9a66; Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 references MJ unit group 93a60a57-a3c8-11da-a746-0800200c9a66.

5. System Boundary

Boundary Abstraction

FieldValue
declared_starting_conditionActual own-account design project inception; identify existing designs, tools, research and facilities
starting_condition_roleForeground creation with explicit linked upstream supplies
product_classification_scopeCPC 3.0 83920
recursive_input_ruleRecord reused original once with its upstream burden and beneficiary ledger; expanded in-house creation replaces the corresponding purchased exchange
upstream_dataset_requirementActual supplied material state, equipment configuration, region/year, provider scope and waste treatment; unknown layers remain disclosed
disclosureActual design route, rejected iterations, make/buy split, stocks, cutoff, resource ownership and missing inventories; foreground-only is not complete cradle-to-gate
rule_idApplies toRulesource_ids
creationall processesInclude attributable brief formation, concept development, physical/digital iteration, verification, documentation, version archiving and initial handoff through the defined cutoff. The Double Diamond informs decomposition; it is not a compulsory fixed sequence or energy recipe.un-cpc3-design-originals; design-council-double-diamond
actual_routesdevelopment and verificationBuild a route-to-exchange register from actual project records. The PLA and UV proof rows are conditional examples, not the category boundary. Machining, other polymers, drawing media, travel, heating/cooling, water and cleaning must be expanded as individual exchanges when present. Salaries and sale rights are not physical exchanges.design-council-double-diamond
later_useasset and copiesSeparate later manufacturing of designed goods, replication/download, operational use, long-term hosting, network delivery and license administration. Declare initial archive/transfer scope; retain creation burden once in the original ledger, never its entire inventory for every copy.un-cpc3-design-originals
providersowned and external resourcesOwned utilities and hardware are collected separately. A complete purchased rendering, storage or validation service substitutes for its embedded utility/device rows; record actual scoped delivery and provider inventory. Missing provider layers block completeness.gsf-sci-1-1-0
elementarydirect releasesNo direct elementary release is assumed for electronic concept creation. Screen actual printing, mockup, solvent, refrigerant and fuel operations; add each evidenced substance with origin, environmental compartment and state. Utility and hardware upstream emissions stay in upstream datasets. Technical water and waste are not elementary-resource flows.design-council-double-diamond

6. Process Inventory Structure

Process Map

process_idprocess_nameinclusioninclusion_conditionrolequantitative_reference
briefBrief and design objectiverequiredAll originalsforeground creationper declared reference flow
developmentConcept development and iterationrequiredAll originals; physical/digital route declaredforeground creationper declared reference flow
mockupPhysical mockup fabricationconditionalPhysical mockups actually madeforeground creationper declared reference flow
proofUV printed proof creationconditionalIn-house UV printed proofs actually madeforeground creationper declared reference flow
verificationDesign verificationrequiredAll originals; actual internal/external checks declaredforeground creationper declared reference flow
masteringOriginal completion and initial handoffrequiredAll originalsforeground creationper declared reference flow
supportShared design infrastructureconditionalShared equipment/facilities usedforeground creationper declared reference flow

Process: Brief and design objective (brief)

Inputs

Product flows
Alternating current (brief_electricity)

Only for measured CN grid-average user supply below 1 kV supporting project definition; other geography/voltage requires its own verified row.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ
  • Amount rule: Measured attributable electricity using cp_energy.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per declared reference flow
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_energy
  • Sources: gsf-sci-1-1-0
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Elementary flows

Process: Concept development and iteration (development)

Inputs

Product flows
Alternating current (development_electricity)

CN below 1 kV only; actual sketching, CAD, graphic editing, rendering and iterative development, including rejected alternatives.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ
  • Amount rule: Measured attributable electricity using cp_energy.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per declared reference flow
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_energy
  • Sources: gsf-sci-1-1-0
paper, woodfree, uncoated (sketch_paper)

Conditional on actual uncoated woodfree paper used for sketches or paper converting mockups; coated paper and printed proof services need separate identities.

  • Selected flow: paper, woodfree, uncoated 58075527-56bb-4c6a-a78a-7d1a3f1db2da
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Measured paper consumption using cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per declared reference flow
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: design-council-double-diamond
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Discarded uncoated woodfree sketch paper (sketch_paper_waste)

Conditional on discarded sketch sheets crossing to a documented receiver; disclose coatings, contamination, moisture and treatment.

  • Selected flow: Discarded uncoated woodfree sketch paper
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Weighed outgoing paper using cp_material; no assumed recycling credit.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per declared reference flow
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: design-council-double-diamond
Elementary flows

Process: Physical mockup fabrication (mockup)

Inputs

Product flows
Polylactic acid printing filament (pla_filament)

Conditional on actual PLA filament mockup printing. Record polymer origin, grade, pigment/additives, diameter and supplier conversion inventory; bulk PLA resin is not filament.

  • Selected flow: Polylactic acid printing filament
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Measured filament consumption using cp_material, including supports and failed prints.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per declared reference flow
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: design-council-double-diamond
Alternating current (mockup_electricity)

Only actual CN below 1 kV mockup production supply; metering includes machine startup and idle attributable to this job.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ
  • Amount rule: Measured attributable electricity using cp_energy.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per declared reference flow
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_energy
  • Sources: gsf-sci-1-1-0
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Discarded polylactic acid mockup and printing supports (pla_scrap)

One PLA waste stream only when discarded. Declare additives, receiver and treatment; retained mockups are project stocks, separately reconciled.

  • Selected flow: Discarded polylactic acid mockup and printing supports
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Weighed outgoing PLA waste using cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per declared reference flow
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: design-council-double-diamond
Elementary flows

Process: UV printed proof creation (proof)

Inputs

Product flows
Ink (uv_ink)

Only actual UV-curing ink for in-house proof creation; specify formulation, color, curing route and safety data. Do not use this identity for ordinary inkjet ink. Add measured curing utilities and supported releases separately.

  • Selected flow: Ink 7627af63-d2c2-4245-906f-023847c7739f
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Measured consumed UV ink using cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per declared reference flow
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: design-council-double-diamond
Alternating current (proof_electricity)

Only actual CN grid-average user supply below 1 kV for proof printing and UV curing; no presumed energy factor.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ
  • Amount rule: Measured attributable electricity using cp_energy.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per declared reference flow
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_energy
  • Sources: gsf-sci-1-1-0
paper, woodfree, uncoated (proof_paper)

Conditional on this exact substrate used in UV printed proofs; verify supplier coating and curing compatibility; do not substitute this paper for other media.

  • Selected flow: paper, woodfree, uncoated 58075527-56bb-4c6a-a78a-7d1a3f1db2da
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Measured paper consumption using cp_material.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per declared reference flow
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: design-council-double-diamond
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Discarded UV-ink printed woodfree paper proof (proof_waste)

Conditional on actual discard; document cured ink composition, moisture, contamination, receiver and waste classification. Retained proofs are reconciled as stock.

  • Selected flow: Discarded UV-ink printed woodfree paper proof
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Weighed outgoing proof using cp_material; no automatic recycling credit.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per declared reference flow
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_material
  • Sources: design-council-double-diamond
Elementary flows

Process: Design verification (verification)

Record actual checks and acceptance against the declared design objective; internal verification electricity is included in the development meter ledger and tagged to this process without duplication. External dimensional inspection is one conditional purchased input.

Inputs

Product flows
Dimensional inspection report for design mockup (dimensional_report)

Conditional on purchased dimensional verification; one scoped report with object, tolerances, method and acceptance. Other outsourced work needs separate atomic deliverables.

  • Selected flow: Dimensional inspection report for design mockup
  • Flow property / unit: Number of items 01846770-4cfe-4a25-8ad9-919d8d378345 / item
  • Amount rule: Actual attributable accepted report count using cp_service.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per declared reference flow
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_service
  • Sources: design-council-double-diamond
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Elementary flows

Process: Original completion and initial handoff (mastering)

Inputs

Product flows
Alternating current (mastering_electricity)

Only CN below 1 kV electricity for actual finalization, integrity checks, version archive and initial handoff through declared completion cutoff.

  • Selected flow: Alternating current 50657322-939c-4829-a87b-47c093bfa6a7
  • Flow property / unit: Net calorific value 93a60a56-a3c8-11da-a746-0800200c9a66 / MJ
  • Amount rule: Measured attributable electricity using cp_energy.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per declared reference flow
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_energy
  • Sources: gsf-sci-1-1-0
Waste flows
Elementary flows

Outputs

Product flows
Own-account design original package (reference_product_original)

A complete original concept asset, not each document, licensing transaction, printed copy or download.

  • Selected flow: Own-account design original package
  • Flow property / unit: Number of items 01846770-4cfe-4a25-8ad9-919d8d378345 / item
  • Amount rule: 1 item
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per declared reference flow
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_original
  • Sources: un-cpc3-design-originals
Waste flows
Elementary flows

Process: Shared design infrastructure (support)

Inputs

Product flows
Assembled ADP system unit (design_computer)

Conditional on actual configured unpackaged system units used for this project. Preserve Mass: weigh the identified unit; attribute its embodied inventory by observed reservation and evidenced device life. Displays and peripherals are separate; a matching hardware inventory is required.

  • Selected flow: Assembled ADP system unit 65153264-5c6b-406f-b113-7d5ad591591b
  • Flow property / unit: Mass 93a60a56-a3c8-11da-a746-0800200b9a66 / kg
  • Amount rule: Attributable measured hardware mass using cp_device; record allocation evidence and no assumed lifetime.
  • Value mode: Foreground record (foreground_record)
  • Specificity: Site-specific (site_specific)
  • Normalization basis: per declared reference flow
  • Basis kind: Process output (process_output)
  • Evidence kind: Collected record (collected_record)
  • Collection protocol: cp_device
  • Sources: gsf-sci-1-1-0
Waste flows
Elementary flows

Outputs

Product flows
Waste flows
Elementary flows

7. Allocation and Co-product Handling

rule_idApplies toRulesource_ids
allocation_projectiterations and multiple originalsAssign directly traceable tasks and supplies to their original first. Retain rejected alternatives supporting the completed design. Split independently delivered originals by measured causal work/resource records; reconcile shares to the whole pool. Count division is allowed only for demonstrated equivalent beneficiaries, not assumed equal designs or sale prices. An abandoned project without an output must be separately disclosed rather than silently removed.un-cpc3-design-originals; design-council-double-diamond
allocation_sharedelectricity and infrastructureMeter each job where possible. For shared supplies use a documented reservation/operation/idle ledger and measured load attribution; reconcile to facility meters. Do not turn CPU hours, stored GB or transferred GB into electricity without a measured device/provider relationship. Device inventory shares require observed reserved time/resources and evidenced device service life, with sensitivity and residual disclosure.gsf-sci-1-1-0
allocation_inheritedreused design and researchIdentify prior originals and purchased evidence; keep a source-to-beneficiary burden ledger. Separate additional version work from inherited work. A copy is not another original and no unsubstantiated lifetime copy count is a denominator. Retained prototype stock, sold physical prototypes and waste transfers require separate quantities and downstream boundaries; no automatic avoided-product credit.un-cpc3-design-originals

8. Foreground Data Collection, Calculation, and Quality Rules

Data Collection Protocols

protocol_idprocess_idflow_rolerecord_typeraw_fieldscollection_methodunitfrequencytemporal_coveragesite_scopeaggregation_rulequality_evidence
cp_originalmasteringreference outputacceptance_recordoriginal ID; project; version; content list; acceptance; rights; dates; own-account statusInspect versioned master, design brief, verification results and signed completeness record; count the complete package once.itemAt completion and each new versionFull actual creation cycleAll project sites and providersper declared reference flowContent integrity; acceptance and rights evidence
cp_energybrief; development; mockup; proof; masteringelectricitymeter_recordmeter ID; kWh; timestamps; site; voltage; stage/job; idle; share; uncertaintyRead calibrated plug/submeters and facility bills; reconcile job records and shared attributable load, including actual supporting cooling and transfer through cutoff. Separate provider-owned power.kWhEach job and metering intervalComplete creation cycleActual owned supply interfacesper declared reference flowCalibration; meter reconciliation; allocation ledger
cp_materialdevelopment; mockup; proofmaterial and separate waste rowsweighing_recordrow; batch; grade; composition; mass; opening/closing stock; receipts; waste destinationWeigh each material and separate waste stream on calibrated scales; reconcile consumption and stock with sketches, proofs, retained models, failed trials and receiver tickets.kgEach batch and waste dispatchFull creation including failuresDeclared actual routeper declared reference flowScale calibration; supplier grade; stock balance; receiver evidence
cp_serviceverificationpurchased dimensional reportdelivery_recordreport ID; mockup; method; tolerance; test date; acceptance; provider inventory; included resourcesInspect accepted dimensional report and provider inventory; allocate its actual scoped work to the declared original and exclude already included utilities.itemEach deliveryActual verification periodDeclared provider and objectper declared reference flowAcceptance; object identity; provider completeness
cp_devicesupportconfigured system unitasset_recordasset/configuration ID; measured net mass; reserved time; capacity share; device life evidence; upstream scopeWeigh the configured unpackaged unit or obtain traceable measured mass for that configuration; reconcile device reservation and service-life records with project logs and upstream hardware inventory.kgEach asset and project intervalActual project and equipment service periodsUsed configured equipment onlyper declared reference flowMass traceability; reservation records; life sensitivity; separate peripherals

Calculation Rules

rule_idApplies toFormula or ruleInputsOutputsource_ids
calculate_energyall electricity rowsMultiply attributable measured kWh by 3.6 to obtain MJ at the identical interface and original basis.cp_energy; kWhMJgsf-sci-1-1-0
calculate_original_inventoryall inventory rowsSum the nonduplicated exchange amounts already attributed to the one declared original. Retain original numerator units; the accepted reference output is exactly 1 item. Establish shared-resource shares before aggregation and reconcile all stage pools.cp_original; stage records; attribution ledgerper declared reference flowun-cpc3-design-originals; design-council-double-diamond; gsf-sci-1-1-0

Data Quality Requirements

requirement_idApplies toRequirementEvidence
quality_originalreference outputBind the actual design objective, original/version, completeness, validation limitations and reuse rights. Related designs are not comparable solely by item count.cp_original; un-cpc3-design-originals
quality_routeall processesMap every actual route to atomic supplies, stocks, waste and supported direct releases; distinguish absent, measured zero and unknown. Do not omit physical design work merely because the final asset is digital.cp_material; project route register; design-council-double-diamond
quality_timeproject resourcesUse complete actual dates, failed iterations and site/provider changes. Quantify missing periods and representativeness; no default energy, yield, recipe or life.cp_energy; cp_original
quality_identityupstream and selected flowsMatch state, substance, composition, supply route, geography, reference property and unit group; record uncertainty, device allocation sensitivity and unresolved identities.cp_device; supplier evidence; public identities

9. Validation Rules

rule_idApplies toRulesource_ids
validate_originalreference_product_originalVerify own-account design-concept asset, one complete version and all qualifiers; reject commissioned service, research result, software product or each license/copy counted as the original.un-cpc3-design-originals
validate_unitsall inventory rowsRequire linked protocols, identical per declared reference flow basis in both languages and traceable numerator units. Never infer design mass or traffic-to-energy conversion.gsf-sci-1-1-0
validate_completenessactual design routesIncomplete route registers, unknown provider layers, unresolved physical supplies or unsupported direct releases block dataset completeness. A conditionally absent row needs occurrence evidence; mandatory internal design verification cannot be replaced by omitting the optional purchased report.design-council-double-diamond
validate_attributionshared and inherited resourcesReconcile project stage pools, supplier/owned interfaces, asset allocation and beneficiary ledgers. Reject duplicated original burden, device inventory or electricity and unproven price allocation.un-cpc3-design-originals; gsf-sci-1-1-0
validate_identityselected flowsRecheck actual public identity, reference property and unit group; for elementary exchanges match origin and environmental subcompartment. Blank identities remain explicit candidate gaps and prevent a complete usable dataset claim until resolved.un-cpc3-design-originals

10. Published Dataset Profile

FieldValue
dataset_roleforeground_dataset
downstream_usesecondary_dataset; background_dataset
allowed_useDeclared original creation inventory with transparent upstream links and reuse ledger; comparison only for equivalent objectives, specification, rights and boundaries
excluded_useStandalone downloads, software operation, broadcast, research or service inventories; complete cradle-to-gate without all upstream layers; legal, safety or environmental superiority approval
required_metadataOriginal/project ID; version; design type and objective; own-account scope; actual route; rights; acceptance; geography; dates; units; allocation; cutoff; upstream identities
required_quality_disclosureUnknown suppliers/identities; missing periods; omitted routes; instrument uncertainty; shared allocation and inherited burden sensitivity; representativeness limits
update_triggerNew original version or changed route, specification, provider, device allocation, supply region or boundary; preserve prior version ledger

11. Data Sources

Source idTypeReferenceUsed for
un-cpc3-design-originalsofficial_guidanceUNSD, CPC Version 3.0, 83920 Design originals — https://unstats.un.org/unsd/classifications/Econ/Structure/Detail/EN/2100/83920Explanatory note: own-account industrial/aesthetic/graphic concept assets intended for sale/licensing; classification only, no inventory values
design-council-double-diamondofficial_guidanceDesign Council, The Double Diamond — https://www.designcouncil.org.uk/our-resources/the-double-diamond/Discover/define/develop/deliver and iterative testing, page headings and process graphic; process framing only, no compulsory factory route, recipe or factor
gsf-sci-1-1-0standardGreen Software Foundation, Software Carbon Intensity Specification 1.1.0 — https://sci.greensoftware.foundation/Energy, Embodied emissions and Software boundary sections inform computing interfaces and measured allocation; software-carbon scope only, not a complete multi-impact design PCR or default factor

Raw downloads

These files are byte-identical to the canonical files for this revision in the repository.

Structured rule index

This index comes from verified structured.yaml and retains the canonical English rule text.

System boundary rules · 5
Rule IDApplies toRuleSource IDs
creationall processesInclude attributable brief formation, concept development, physical/digital iteration, verification, documentation, version archiving and initial handoff through the defined cutoff. The Double Diamond informs decomposition; it is not a compulsory fixed sequence or energy recipe.un-cpc3-design-originals, design-council-double-diamond
actual_routesdevelopment and verificationBuild a route-to-exchange register from actual project records. The PLA and UV proof rows are conditional examples, not the category boundary. Machining, other polymers, drawing media, travel, heating/cooling, water and cleaning must be expanded as individual exchanges when present. Salaries and sale rights are not physical exchanges.design-council-double-diamond
later_useasset and copiesSeparate later manufacturing of designed goods, replication/download, operational use, long-term hosting, network delivery and license administration. Declare initial archive/transfer scope; retain creation burden once in the original ledger, never its entire inventory for every copy.un-cpc3-design-originals
providersowned and external resourcesOwned utilities and hardware are collected separately. A complete purchased rendering, storage or validation service substitutes for its embedded utility/device rows; record actual scoped delivery and provider inventory. Missing provider layers block completeness.gsf-sci-1-1-0
elementarydirect releasesNo direct elementary release is assumed for electronic concept creation. Screen actual printing, mockup, solvent, refrigerant and fuel operations; add each evidenced substance with origin, environmental compartment and state. Utility and hardware upstream emissions stay in upstream datasets. Technical water and waste are not elementary-resource flows.design-council-double-diamond
Allocation rules · 3
Rule IDApplies toRuleSource IDs
allocation_projectiterations and multiple originalsAssign directly traceable tasks and supplies to their original first. Retain rejected alternatives supporting the completed design. Split independently delivered originals by measured causal work/resource records; reconcile shares to the whole pool. Count division is allowed only for demonstrated equivalent beneficiaries, not assumed equal designs or sale prices. An abandoned project without an output must be separately disclosed rather than silently removed.un-cpc3-design-originals, design-council-double-diamond
allocation_sharedelectricity and infrastructureMeter each job where possible. For shared supplies use a documented reservation/operation/idle ledger and measured load attribution; reconcile to facility meters. Do not turn CPU hours, stored GB or transferred GB into electricity without a measured device/provider relationship. Device inventory shares require observed reserved time/resources and evidenced device service life, with sensitivity and residual disclosure.gsf-sci-1-1-0
allocation_inheritedreused design and researchIdentify prior originals and purchased evidence; keep a source-to-beneficiary burden ledger. Separate additional version work from inherited work. A copy is not another original and no unsubstantiated lifetime copy count is a denominator. Retained prototype stock, sold physical prototypes and waste transfers require separate quantities and downstream boundaries; no automatic avoided-product credit.un-cpc3-design-originals
Validation rules · 5
Rule IDApplies toRuleSource IDs
validate_originalreference_product_originalVerify own-account design-concept asset, one complete version and all qualifiers; reject commissioned service, research result, software product or each license/copy counted as the original.un-cpc3-design-originals
validate_unitsall inventory rowsRequire linked protocols, identical per declared reference flow basis in both languages and traceable numerator units. Never infer design mass or traffic-to-energy conversion.gsf-sci-1-1-0
validate_completenessactual design routesIncomplete route registers, unknown provider layers, unresolved physical supplies or unsupported direct releases block dataset completeness. A conditionally absent row needs occurrence evidence; mandatory internal design verification cannot be replaced by omitting the optional purchased report.design-council-double-diamond
validate_attributionshared and inherited resourcesReconcile project stage pools, supplier/owned interfaces, asset allocation and beneficiary ledgers. Reject duplicated original burden, device inventory or electricity and unproven price allocation.un-cpc3-design-originals, gsf-sci-1-1-0
validate_identityselected flowsRecheck actual public identity, reference property and unit group; for elementary exchanges match origin and environmental subcompartment. Blank identities remain explicit candidate gaps and prevent a complete usable dataset claim until resolved.un-cpc3-design-originals
Processes and inputs/outputs · 7
Process IDProcess nameInput flowsOutput flows
briefBrief and design objective10
developmentConcept development and iteration21
mockupPhysical mockup fabrication21
proofUV printed proof creation31
verificationDesign verification10
masteringOriginal completion and initial handoff11
supportShared design infrastructure10

Complete field inspector

Loads this record’s complete manifest and structured projection on demand; values are never truncated. Requires JavaScript.

On this page