  "pcr_id": "pcr.other-transportable-goods-except-metal-products-machinery-and-equipment.rubber-and-plastics-products.compression-sintered-virgin-ptfe-flat-gaskets",
  "language": "en-US",
  "sync_with": "pcr.zh-CN.md",
  "status": "candidate",
  "content_maturity": "authored_methodology",
  "translation_status": "canonical"
}
---

# Cold-compressed and freely sintered virgin PTFE flat gasket manufacture

Global applicability for all following rule families: This attributional method manufactures one drawing-specific unfilled non-expanded virgin PTFE flat annular gasket at a declared CN site. Begin with the whole purchased conventional homopolymer granular moulding powder, verified for cold compression; receive/store/condition/screen, uniformly charge and cold-press a preform, demould, freely sinter in an electrically heated ventilated batch oven, cool under the actual controlled programme, directly dry-turn/bore/part and deburr the billet into solid one-piece gaskets, inspect/test and uniquely first release. Retain real failed batches, warm-up, idle, start/stop, extraction, cleanup, rework and utilities. Subsequent actual FG storage/packing/handling/dispatch is a separately reported original-cohort service account. [daikin-ptfe-moulding-2019; daikin-ptfe-m17-2016; teadit-ptfe-gaskets-2023; doing-ptfe-oven]

Exclude filled or chemically modified PTFE; expanded or structured PTFE; paste lubricant extrusion; ram or isostatic moulding; hot coining/water quench; purchased sheet/billet conversion; sheet skiving and sheet-cut gaskets; melt injection; elastomer or metal-composite seals; spring-energized seals; welded segments; resin synthesis; coatings/printing; medical implantation; oxygen-service cleaning; fuel-fired sintering; bought-finished-gasket repacking; installation/use/end of life. A real departure requires renewed applicability and complete atomic exchanges.

## 1. Scope and Applicability

This attributional method manufactures one drawing-specific unfilled non-expanded virgin PTFE flat annular gasket at a declared CN site. Begin with the whole purchased conventional homopolymer granular moulding powder, verified for cold compression; receive/store/condition/screen, uniformly charge and cold-press a preform, demould, freely sinter in an electrically heated ventilated batch oven, cool under the actual controlled programme, directly dry-turn/bore/part and deburr the billet into solid one-piece gaskets, inspect/test and uniquely first release. Retain real failed batches, warm-up, idle, start/stop, extraction, cleanup, rework and utilities. Subsequent actual FG storage/packing/handling/dispatch is a separately reported original-cohort service account. [daikin-ptfe-moulding-2019; daikin-ptfe-m17-2016; teadit-ptfe-gaskets-2023; doing-ptfe-oven]

Daikin establishes conventional granular powder and cold-press/free-bake processing; Teadit independently describes direct machining after cooling into sealing products; Doing establishes real electric-resistance batch-oven capability and also fuel-fired alternatives. This is transparent complementary technical synthesis, not one SKU/recipe/factory/current order. No brochure density, particle size, pressure, temperature, time, power, weight, yield, emission factor, creep result, torque, service life or certification is a default. Daikin NEW modified grades and the Teadit expanded/structured variants are countercontexts; Tables1/2/4/8, Figs3–8 and adjacent notes do not establish interchangeable materials or universal programmes. The supplier warning mentioning HCl is not proof that pure PTFE contains chlorine; retain actual precursor/speciation evidence. [daikin-ptfe-moulding-2019; daikin-ptfe-m17-2016; teadit-ptfe-gaskets-2023; doing-ptfe-oven]

Exclude filled or chemically modified PTFE; expanded or structured PTFE; paste lubricant extrusion; ram or isostatic moulding; hot coining/water quench; purchased sheet/billet conversion; sheet skiving and sheet-cut gaskets; melt injection; elastomer or metal-composite seals; spring-energized seals; welded segments; resin synthesis; coatings/printing; medical implantation; oxygen-service cleaning; fuel-fired sintering; bought-finished-gasket repacking; installation/use/end of life. A real departure requires renewed applicability and complete atomic exchanges.

## 2. Product Category Identity

| Field | Value |
| --- | --- |
| canonical_pcr_id | pcr.other-transportable-goods-except-metal-products-machinery-and-equipment.rubber-and-plastics-products.compression-sintered-virgin-ptfe-flat-gaskets |
| classification_refs | CPC3.0:36990; narrower proposed context only; accepted narrower association is governed by classifications/mappings/cpc-3.0-to-pcr.yaml and its decision record; scientific review remains pending |
| covered_products | One-piece unfilled non-expanded virgin-PTFE flat annular industrial gaskets within section1 |
| excluded_products | Exclude filled or chemically modified PTFE; expanded or structured PTFE; paste lubricant extrusion; ram or isostatic moulding; hot coining/water quench; purchased sheet/billet conversion; sheet skiving and sheet-cut gaskets; melt injection; elastomer or metal-composite seals; spring-energized seals; welded segments; resin synthesis; coatings/printing; medical implantation; oxygen-service cleaning; fuel-fired sintering; bought-finished-gasket repacking; installation/use/end of life. A real departure requires renewed applicability and complete atomic exchanges. |
| representative_product | One actual drawing-specific conventional solid PTFE ring; no fixed brand or dimensions |
| production_route | Whole granular powder → cold preform → electric free sintering → controlled cooling → direct dry machining → inspection/first release → separate actual services |
| market_state | Cooled dry-machined complete bare gasket at unique first release; actual moisture declared; all packaging excluded from net mass |

The original UN structure places36990 beside specific household, builders, lamp-part, headgear and insulating-fitting categories; the residual leaf is not a universal plastics method. The material library and frozen neighboring routes do not cover this solid PTFE cold-press/sinter/direct-machined industrial sealing endpoint. [un-cpc3-2025]

## 3. Reference Flow

| Field | Value |
| --- | --- |
| What | Supply a complete flat annular industrial sealing gasket for its declared joint |
| How much | 1 kg of new uniquely first-released bare gaskets |
| How well | Meet the declared drawing and application-specific dimensional/surface/material/sealing acceptance; mass does not establish equivalent sealing service |
| How long or cycle | Manufacturing declared unit at first release; actual design/service duty disclosed without invented lifetime |
| reference_flow_link | finished_gasket |

| Field | Value |
| --- | --- |
| Reference amount | 1 |
| Reference product flow | Sealing elements `a9943e4e-1a21-412c-859e-df09a2b5ee6f` |
| Reference flow property | Mass `93a60a56-a3c8-11da-a746-0800200b9a66` |
| Reference unit group | Units of mass `93a60a57-a4c8-11da-a746-0800200c9a66` |
| Reference unit | kg |
| Required qualifiers | Actual CN site and period; Drawing revision and ring dimensions; Conventional virgin homopolymer grade and supplier; Granular moulding-powder particle form and supplied composition; No filler or chemical modification or expansion; Powder handling temperature and contamination controls; Cold-press and free-sinter/cooling programme and load geometry; Electric resistance heat and actual ventilation/abatement; Direct dry machining and actual recovery/rejection state; Release specification and sealing test context including flange/media/service conditions; Bare net measured kg and actual moisture/conditioning state; Unique first-release cohort and disjoint WIP/FG/non-WIP vectors; Separate post-release service interval and physical movements; Native generic seal identity and rubber-classification caveat; Native CN user-side grid electricity below1kV when bound; Actual incoming and outgoing package composition and custody; Actual species and air compartment with uncertainty and missing coverage |

Declare every qualifier in the foreground package and preserve the entire finished_gasket card restriction; generic identity does not establish service equivalence, material/provider compatibility or an accepted mapping.

## 4. Measurement and Unit Rules

| rule_id | Applies to | Required property | Required unit | Rule |
| --- | --- | --- | --- | --- |
| reference_mass | reference product | Mass `93a60a56-a3c8-11da-a746-0800200b9a66` | kg | Use actual bare net mass at unique first release; measure moisture/conditioning and exclude all packages. Use cp_release and calc_q; no per-item mass or density guessed. |
| numerator_units | all inventory rows | row-specific | row-specific | Preserve raw units and rate/total flags. Apply calc_units and evidenced allocation before calc_normalize_once; exactly one A/Q normalization. |

## 5. System Boundary

### Boundary Abstraction

| Field | Value |
| --- | --- |
| declared_starting_condition | Whole purchased conventional unfilled virgin PTFE granular moulding powder at receipt; include actual inbound freight and upstream powder supply |
| starting_condition_role | foreground collection gate; upstream supply remains linked background |
| product_classification_scope | Narrow36990 industrial PTFE flat gasket subset; classification is not method approval |
| recursive_input_rule | Internal powder/preform/billet/rework transfers retain cohort history and cancel on consolidation; bought released gasket is not a new raw input route |
| upstream_dataset_requirement | Match delivered whole powder grade/form/route and every actual supply/service state; preserve transport and package inclusions without duplicate upstream purchases |
| disclosure | Declare complete failed/zero-output loads; WIP and non-WIP physical stock and every inherited exchange vector; distinct first-release and FG service gates; all real species/streams and gaps |

| rule_id | Applies to | Rule | source_ids |
| --- | --- | --- | --- |
| b_route | all manufacturing | Include raw-powder handling, actual cold pressing, all oven ramps/holds/cooling and ventilation, direct machining, cleanup, failed trials, rework, testing and first release. A purchased finished gasket is not a substitute for this route. Add each actual unlisted exchange with a specific identity; no residual other-material bucket or unsupported zero. | daikin-ptfe-moulding-2019; daikin-ptfe-m17-2016; teadit-ptfe-gaskets-2023; doing-ptfe-oven |
| b_q | manufacturing and FG | Q is the sum of net kg at each unique NEW first-quality-release event after machining/testing. Reinspection, dispatch, return or repeated repair-release creates no new Q. Closing FG already in Q is a custody stock, never a second manufacturing output. Keep actual packaging/storage/handling/dispatch and return-inspection services as incremental original-cohort accounts; merging cancels the internal release transfer and preserves the single production burden. | teadit-ptfe-gaskets-2023 |
| b_vectors | all cohort stocks | Keep disjoint opening/closing raw powder, green preform, sintered billet, machined WIP, FG and rework physical quantities with a historical vector for EACH exchange. Independently retain non-WIP press/lathe/oven equipment service, hydraulic/gear oil, coolant-water and refrigerant charges and vectors, including idle/maintenance. Allocate real utility consumption or a measured-consumption equivalent with inventory correction once; never subtract stock twice or erase inherited burden. Returned gaskets carry original production once; only actual additional repair materials/energy and old component wastes are new. A changed composition/geometry requires renewed applicability. | daikin-ptfe-moulding-2019; jrc-ilcd-2010 |
| b_packages | each package | For EACH incoming drum/liner and outgoing bag/carton/tape/pallet independently: opening empty + opening attached WIP/FG + opening reusable + purchases + external returns received = closing empty + closing attached WIP/FG + closing reusable + packages on gross physical shipments + external returns sent + waste. Stock categories are disjoint. Internal reuse cancels, is neither another purchase nor Q nor automatic coproduct. Preserve original burdens and real repair/replacement materials and wastes; supplier-included packaging is not purchased again. Separate gross physical movement from net financial shipments. | jrc-ilcd-2010 |
| b_physical | manufacturing/FG/consolidated gates | Reconcile complete physical mass and relevant C/F and actual other-element balances independently of measured molecular species. No single residual may determine two unknowns. Keep free water, actual reaction water, vapour and any structure/phase-bound water distinct; PTFE morphology/density change does not create water. Measure FG moisture separately. Native TFE CAS116-14-3 denotes monomer, never PTFE dust CAS9002-84-0. Actual external liquid heat-exchange return is a Product output with temperature/enthalpy and supplier water/energy agreement; actual oily condensate is separate waste. Do not invent steam/boilers or count a returned-water burden twice. | daikin-ptfe-moulding-2019; daikin-ptfe-m17-2016; teadit-ptfe-gaskets-2023 |

## 6. Process Inventory Structure

### Process Map

| process_id | process_name | inclusion | inclusion_condition | role | quantitative_reference |
| --- | --- | --- | --- | --- | --- |
| prepare | Receipt and powder preparation | required | actual operations within section1 including zero output | foreground | 1 kg reference flow |
| form | Cold preforming and electric free sintering/cooling | required | actual operations within section1 including zero output | foreground | 1 kg reference flow |
| machine | Direct dry machining and first release | required | actual operations within section1 including zero output | foreground | 1 kg reference flow |
| utilities | Actual utilities and equipment service | required | actual operations within section1 including zero output | foreground | 1 kg reference flow |
| service | Actual post-release FG services | conditional | actual original-cohort services only | foreground | 1 kg reference flow |

Internal powder/preform/billet and release-to-FG transfers are stage ledgers, not repeated external purchases. Each card describes one physical exchange; conditional means verify actual presence/absence, not assume zero. Add every actually present unlisted material/species with an atomic card and protocol, including real cleaning agents, filter housing, cooling treatment or repair components.

### Process: Receipt and powder preparation (`prepare`)

#### Inputs

##### Product flows

###### Whole virgin granular moulding powder (`powder`)

Whole purchased conventional unfilled virgin granular homopolymer moulding powder; CAS9002-84-0; native at-plant/virgin-polymer Product identity does not establish particle grade, provider or recipe. Verify the actual granular cold-compression form; dispersion, micropowder, paste fine powder, filled/modified/reprocessed grades are not substitutions. Buy the supplied preparation once; assay/residual water are subaccounts only. Preserve raw and green-WIP vectors.

- Selected flow: PTFE resin `f1adfc87-da88-4bcb-ace7-d6b809049f56`
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_material.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_material`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`

###### Fibreboard resin drum received (`drum_in`)

Actual complete incoming resin drum including its declared fixed closure; separately supplied closure requires a new card. Record actual purchased quantity and external returns received separately, supplier-included package without a second purchase. Reconcile b_packages with disjoint empty/attached-WIP/FG/reusable stocks, internal reuse cancelled and original exchange vectors carried once.

- Selected flow: Fibreboard resin drum
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_packaging.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_packaging`
- Sources: `daikin-ptfe-moulding-2019`; `jrc-ilcd-2010`

###### Polyethylene resin-drum liner received (`liner_in`)

Actual whole inner liner, separate from drum and resin; no resin sack assumed from another supplier. Record actual purchased quantity and external returns received separately, supplier-included package without a second purchase. Reconcile b_packages with disjoint empty/attached-WIP/FG/reusable stocks, internal reuse cancelled and original exchange vectors carried once.

- Selected flow: Polyethylene resin-drum liner
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_packaging.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_packaging`
- Sources: `daikin-ptfe-moulding-2019`; `jrc-ilcd-2010`

###### Actual inbound road freight (`freight`)

Conditional actual inbound road service with loaded route and whole shipment mass; keep supplier-delivered transport inclusions to avoid duplicate purchase. Other actual transport modes require their own specific rows and state; do not invent vehicle or empty-return factor.

- Selected flow: Road freight transport
- Flow property / unit: Transport service / tkm
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_freight.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_freight`
- Sources: `daikin-ptfe-moulding-2019`

##### Waste flows

##### Elementary flows

#### Outputs

##### Product flows

###### Fibreboard resin drum outward custody (`drum_out`)

Actual complete incoming resin drum including its declared fixed closure; separately supplied closure requires a new card. Record packages on gross physical shipments and outward returns separately; this is custody movement, not coproduct production. Reconcile b_packages with disjoint empty/attached-WIP/FG/reusable stocks, internal reuse cancelled and original exchange vectors carried once.

- Selected flow: Fibreboard resin drum
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_packaging.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_packaging`
- Sources: `daikin-ptfe-moulding-2019`; `jrc-ilcd-2010`

###### Polyethylene resin-drum liner outward custody (`liner_out`)

Actual whole inner liner, separate from drum and resin; no resin sack assumed from another supplier. Record packages on gross physical shipments and outward returns separately; this is custody movement, not coproduct production. Reconcile b_packages with disjoint empty/attached-WIP/FG/reusable stocks, internal reuse cancelled and original exchange vectors carried once.

- Selected flow: Polyethylene resin-drum liner
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_packaging.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_packaging`
- Sources: `daikin-ptfe-moulding-2019`; `jrc-ilcd-2010`

##### Waste flows

###### Captured unsintered powder (`powder_waste`)

Weigh separately by contamination and actual receiver. Clean retained internal powder remains a burden-carrying transfer, not another purchase or avoided-resin credit. Do not combine with sintered turning scrap.

- Selected flow: Captured unsintered virgin PTFE powder waste
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_waste.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_waste`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`

###### Fibreboard resin drum waste (`drum_waste`)

Actual complete incoming resin drum including its declared fixed closure; separately supplied closure requires a new card. Weigh actual package waste by receiver and contamination separately from product and other packages. Reconcile b_packages with disjoint empty/attached-WIP/FG/reusable stocks, internal reuse cancelled and original exchange vectors carried once.

- Selected flow: Waste Fibreboard resin drum
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_packaging.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_packaging`
- Sources: `daikin-ptfe-moulding-2019`; `jrc-ilcd-2010`

###### Polyethylene resin-drum liner waste (`liner_waste`)

Actual whole inner liner, separate from drum and resin; no resin sack assumed from another supplier. Weigh actual package waste by receiver and contamination separately from product and other packages. Reconcile b_packages with disjoint empty/attached-WIP/FG/reusable stocks, internal reuse cancelled and original exchange vectors carried once.

- Selected flow: Waste Polyethylene resin-drum liner
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_packaging.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_packaging`
- Sources: `daikin-ptfe-moulding-2019`; `jrc-ilcd-2010`

##### Elementary flows

### Process: Cold preforming and electric free sintering/cooling (`form`)

#### Inputs

##### Product flows

##### Waste flows

##### Elementary flows

###### Actual atmospheric oxygen uptake (`oxygen`)

Conditional independently evidenced oxygen uptake CAS7782-44-7 only if actual oxidative species chemistry consumes it. It is not purchased compressed air, not inferred by fitting two unknown emissions. Balance the actual selected physical gate, with pass-through air/water recorded separately where crossing the declared gate; no assumption that all PTFE loss oxidizes.


Native Elementary Resource from air / renewable element resources from air, CAS7782-44-7, reference Mass index0/factor1 and kg. Use only independently measured ordinary molecular-O2 uptake from ambient air at this declared gate, not an oxygen emission, a purchased gas supply or an assumed fraction of bulk air. Broad native liquid/ion/isotope/phase aliases do not change the actual gas; no fixed geography, grade, quantity or oxidation extent follows. Gross pass-through air and other phases remain separately observed and non-additive with net uptake; do not subtract atmospheric flow without a matched physical/species ledger.

- Selected flow: oxygen `e2fb04b0-6555-11dd-ad8b-0800200c9a66`
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_emission.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_emission`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`

#### Outputs

##### Product flows

##### Waste flows

##### Elementary flows

###### Actual hydrogen fluoride to air (`hf`)

Conditional on independent actual speciation and quantified release, including failed/overheated loads; not a default emitted amount. Native Elementary/Mass/kg; air-unspecified compartment; CAS7664-39-3. actual HF mass, not total fluoride expressed as F. Use another verified compartment if actually known; preserve uncertainty. Supplier fume warning proves neither this quantity nor simultaneous emission of every candidate.

- Selected flow: hydrogen fluoride `08a91e70-3ddc-11dd-9804-0050c2490048`
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_emission.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_emission`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`

###### Actual tetrafluoroethylene to air (`tfe`)

Conditional on independent actual speciation and quantified release, including failed/overheated loads; not a default emitted amount. Native Elementary/Mass/kg; air-unspecified compartment; CAS116-14-3. gaseous monomer only; misleading polymer synonyms do not permit dust. Use another verified compartment if actually known; preserve uncertainty. Supplier fume warning proves neither this quantity nor simultaneous emission of every candidate.

- Selected flow: tetrafluoroethylene `08a91e70-3ddc-11dd-a02a-0050c2490048`
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_emission.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_emission`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`

###### Actual carbon monoxide (fossil) to air (`co`)

Conditional on independent actual speciation and quantified release, including failed/overheated loads; not a default emitted amount. Native Elementary/Mass/kg; air-unspecified compartment; CAS630-08-0. actual fossil-carbon CO only. Use another verified compartment if actually known; preserve uncertainty. Supplier fume warning proves neither this quantity nor simultaneous emission of every candidate.

- Selected flow: carbon monoxide (fossil) `08a91e70-3ddc-11dd-924e-0050c2490048`
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_emission.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_emission`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`

###### Actual carbon dioxide (fossil) to air (`co2`)

Conditional on independent actual speciation and quantified release, including failed/overheated loads; not a default emitted amount. Native Elementary/Mass/kg; air-unspecified compartment; CAS124-38-9. actual fossil-carbon CO2 only, exclude grid upstream repetition. Use another verified compartment if actually known; preserve uncertainty. Supplier fume warning proves neither this quantity nor simultaneous emission of every candidate.

- Selected flow: carbon dioxide (fossil) `08a91e70-3ddc-11dd-923d-0050c2490048`
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_emission.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_emission`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`

###### Carbonyl fluoride to air (`cof2`)

Only actually identified COF2 CAS353-50-4; no UUID adopted. A carbonofluoridate ester is a different molecule. If actual downstream hydrolysis occurs, independently measure consumed water and actual HF/CO2 at their true exit, avoiding double count of precursor and products.

- Selected flow: Carbonyl fluoride to air
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_emission.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_emission`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`

###### Hydrogen chloride to air (`hcl`)

Conditional actual HCl CAS7647-01-0. The old general handbook warning is not evidence of chlorine in pure PTFE; verify real chlorine-bearing contamination/input and independent measured species or document actual absence without a fabricated factor. Native Elementary/Mass/kg, emissions to air unspecified, official baseName hydrogen chloride; broad acid/aqueous/isotope/cleaner synonyms do not authorize another chemical, phase or purchased preparation. Use another independently verified actual compartment when known; actual emitted HCl mass is not total chloride or a default coproduct. Identity establishes neither occurrence nor amount.

- Selected flow: hydrogen chloride `fe0acd60-3ddc-11dd-aab0-0050c2490048`
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_emission.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_emission`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`

### Process: Direct dry machining and first release (`machine`)

#### Inputs

##### Product flows

##### Waste flows

##### Elementary flows

#### Outputs

##### Product flows

###### First-released complete flat gasket (`finished_gasket`)

Exactly one drawing-specific one-piece conventional unfilled non-expanded virgin PTFE flat gasket, cooled and directly dry-machined to its declared flange application. Native Product/Mass/kg at plant CN, for installation during assembly; no CAS, grade, component mix or manufacturing route is prescribed by the native record. Its rubber36270 classification is a disclosed taxonomy inconsistency with the otherwise generic gasket/seal name and synonyms; it is not a rubber-material constraint or a36990 mapping. This qualified use does not authorize elastomer O-rings, mixed seals or installed equipment. Retain drawing, powder form, cooling/machining and sealing acceptance evidence. Packaging excluded; unique first release only.

- Selected flow: Sealing elements `a9943e4e-1a21-412c-859e-df09a2b5ee6f`
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: 1 kg
- Value mode: `fixed_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `method_formula`
- Collection protocol: `cp_release`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`; `teadit-ptfe-gaskets-2023`

##### Waste flows

###### Sintered machining turnings (`turnings`)

Weigh actual dry turnings by billet/cohort and destination. Sintered scrap is not virgin cold-moulding powder; do not presume remoulding, zero burden or automatic recycling credit.

- Selected flow: Sintered virgin PTFE turning waste
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_waste.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_waste`
- Sources: `daikin-ptfe-moulding-2019`; `teadit-ptfe-gaskets-2023`

###### Rejected sintered gasket (`reject`)

Record failed tests and unrecoverable articles separately from turnings. Retained eligible machining rework keeps all history and real additional load without a new Q.

- Selected flow: Rejected sintered virgin PTFE gasket waste
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_waste.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_waste`
- Sources: `daikin-ptfe-moulding-2019`; `teadit-ptfe-gaskets-2023`

##### Elementary flows

###### PTFE particulate to air (`dust`)

Measure airborne polymer particulate mass and size/compartment independently; CAS9002-84-0, not TFE monomer116-14-3. Captured powder/filter waste and uncaptured emissions have separate destinations; do not use total particulate as chemically pure PTFE without composition evidence.

- Selected flow: Virgin PTFE particulate to air
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_emission.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_emission`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`

### Process: Actual utilities and equipment service (`utilities`)

#### Inputs

##### Product flows

###### Alternating current (`electricity`)

Native Product energy represented by Net calorific value/MJ, CN user-side grid-average supply below1kV. Meter actual electric oven, press, machining, extraction, thermal conditioning, pumps/compressor and losses once; capacity/nameplate kW is not consumed energy. Do not use for other voltage/geography or a gas-fired oven.

- Selected flow: Alternating current `50657322-939c-4829-a87b-47c093bfa6a7`
- Flow property / unit: Net calorific value `93a60a56-a3c8-11da-a746-0800200c9a66` / MJ
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_energy.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_energy`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`; `doing-ptfe-oven`

###### Treated tap water (`water`)

Conditional actual delivered treated tap-water mass for indirect press/machinery/circuit make-up or actual cleaning. No direct billet quench in this free-bake route; record each supply/return, opening/closing loop stock and real losses. A CTUe reference property cannot bind this kg exchange.

- Selected flow: Treated tap water
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_water.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_water`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`; `doing-ptfe-oven`

###### Mineral hydraulic oil preparation (`hydraulic_oil`)

Conditional actual whole press hydraulic preparation, not base-oil plus additive repurchases. Independently retain equipment opening/closing charge physical mass and per-exchange inherited history, actual consumption/top-up, recovery/waste/leak and service period.

- Selected flow: Mineral hydraulic oil preparation
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_charge.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_charge`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`; `doing-ptfe-oven`

###### Mineral gear lubricating oil preparation (`gear_oil`)

Conditional actual whole lathe/drive lubricating formulation with distinct chemistry and charge ledger from hydraulic oil. Retain physical stock and inherited vectors through idle/startup/maintenance; actual leakage requires its own destination.

- Selected flow: Mineral gear lubricating oil preparation
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_charge.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_charge`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`; `doing-ptfe-oven`

###### Compressed air (`air`)

Conditional external delivered air only, measured at declared pressure/temperature/humidity and reference state. Internal compressed air cancels and retains compressor electricity, oil, condensate and leakage; never purchase both internal air and its included generation.

- Selected flow: Compressed air
- Flow property / unit: Volume / m3
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_air.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_air`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`; `doing-ptfe-oven`

###### 1,1,1,2-Tetrafluoroethane refrigerant (`r134a`)

Conditional only if actual closed chiller uses CAS811-97-2. Keep equipment opening/closing physical charge and historical exchange vectors independently from WIP/FG; charge, cylinder return, recovery, waste and air leak are separate. Other actual refrigerants require distinct cards; no charge assumed per batch.

- Selected flow: 1,1,1,2-Tetrafluoroethane refrigerant
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_charge.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_charge`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`; `doing-ptfe-oven`

###### Polyester dust-filter cartridge (`filter`)

Conditional actual cartridge of declared polyester media and housing composition; weigh whole bought cartridge once and retain its service-life stock/vector. Different housing/media need specific extra exchanges; captured dust is not another purchased cartridge.

- Selected flow: Polyester dust-filter cartridge
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_charge.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_charge`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`; `doing-ptfe-oven`

###### Hydraulic powder compression press acquired (`press_equipment`)

One specific complete durable machine acquired across the actual boundary. This Product card reports its independently recorded gross physical acquired item count; opening/closing retained units, Product returns/handovers and complete retirement are separate physical quantities. Its upstream per-exchange service-burden attribution is a linked ledger under cp_equipment, not a fractional replacement for this physical count. Retained equipment is not repurchased and its physical unit does not vanish when service is attributed. Actual repair new parts and removed old parts require their own atomic exchanges and vectors. No kg per machine, equal new/old mass, service life or full new machine per batch is assumed.

- Selected flow: Hydraulic powder compression press
- Flow property / unit: Number of items / item
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_equipment.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_equipment`
- Sources: `daikin-ptfe-moulding-2019`; `doing-ptfe-oven`; `jrc-ilcd-2010`

###### Electric resistance batch sintering oven acquired (`oven_equipment`)

One specific complete durable machine acquired across the actual boundary. This Product card reports its independently recorded gross physical acquired item count; opening/closing retained units, Product returns/handovers and complete retirement are separate physical quantities. Its upstream per-exchange service-burden attribution is a linked ledger under cp_equipment, not a fractional replacement for this physical count. Retained equipment is not repurchased and its physical unit does not vanish when service is attributed. Actual repair new parts and removed old parts require their own atomic exchanges and vectors. No kg per machine, equal new/old mass, service life or full new machine per batch is assumed.

- Selected flow: Electric resistance batch sintering oven
- Flow property / unit: Number of items / item
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_equipment.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_equipment`
- Sources: `daikin-ptfe-moulding-2019`; `doing-ptfe-oven`; `jrc-ilcd-2010`

###### CNC dry-machining lathe acquired (`lathe_equipment`)

One specific complete durable machine acquired across the actual boundary. This Product card reports its independently recorded gross physical acquired item count; opening/closing retained units, Product returns/handovers and complete retirement are separate physical quantities. Its upstream per-exchange service-burden attribution is a linked ledger under cp_equipment, not a fractional replacement for this physical count. Retained equipment is not repurchased and its physical unit does not vanish when service is attributed. Actual repair new parts and removed old parts require their own atomic exchanges and vectors. No kg per machine, equal new/old mass, service life or full new machine per batch is assumed.

- Selected flow: CNC dry-machining lathe
- Flow property / unit: Number of items / item
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_equipment.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_equipment`
- Sources: `daikin-ptfe-moulding-2019`; `doing-ptfe-oven`; `jrc-ilcd-2010`

##### Waste flows

##### Elementary flows

#### Outputs

##### Product flows

###### External liquid heat-exchange return (`water_return`)

Only actual external return of the supplied water at measured temperature/enthalpy, agreed supplier heat/water boundary and chemical state; not a waste by default and not invented steam condensate. Internal recirculation cancels.

- Selected flow: Liquid heat-exchange water return
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_water.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_water`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`; `doing-ptfe-oven`

###### Recovered refrigerant outward (`r134a_recovered`)

Conditional actual recovered CAS811-97-2 to a verified recipient and service state; distinguish recovery for reuse from disposal waste, cylinder tare and leakage; retain original charge history without automatic product credit.

- Selected flow: Recovered 1,1,1,2-tetrafluoroethane
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_charge.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_charge`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`; `doing-ptfe-oven`

##### Waste flows

###### Spent hydraulic oil (`oil_waste`)

Measure actual used whole hydraulic preparation by water/contamination state and receiver; do not merge with gear oil or infer lost mass as an emission.

- Selected flow: Spent mineral hydraulic oil
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_charge.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_charge`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`; `doing-ptfe-oven`

###### Spent gear oil (`gear_waste`)

Separate actual lubricant waste and its retained water/solids from hydraulic oil; reconcile with equipment charge vectors.

- Selected flow: Spent mineral gear lubricating oil
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_charge.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_charge`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`; `doing-ptfe-oven`

###### Cooling circuit bleed (`bleed`)

Actual water-based bleed with independent measured solute composition and destination; any treatment chemical added needs its own whole supply card. No COD-as-chemical mass.

- Selected flow: Cooling-loop bleed water
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_water.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_water`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`; `doing-ptfe-oven`

###### Air-compressor condensate (`condensate`)

Only actual oily condensate drained to a waste recipient, measured water/oil state; not returned Product water, not an assumed boiler condensate. If actual clean external product return occurs add that specific stream.

- Selected flow: Oil-contaminated compressed-air condensate
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_water.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_water`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`; `doing-ptfe-oven`

###### Spent dust-filter cartridge (`filter_waste`)

Weigh cartridge and retained dust subaccount separately to avoid double-counting captured PTFE. Identify housing/media and receiver; no automatic recycling credit.

- Selected flow: Spent polyester cartridge containing PTFE dust
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_waste.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_waste`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`; `doing-ptfe-oven`

###### Discarded refrigerant (`r134a_waste`)

Conditional actual CAS811-97-2 waste sent for treatment, separately from recovered reusable product and air emission.

- Selected flow: Discarded 1,1,1,2-tetrafluoroethane
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_charge.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_charge`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`; `doing-ptfe-oven`

###### Discarded Hydraulic powder compression press (`press_equipment_waste`)

Only actual complete retired machine handover; retain physical unit, composition, historical per-exchange vector and receiver. No automatic scrap credit. Disassembly into separately handled materials requires each real atomic output; this card cannot conceal that disassembly.

- Selected flow: Discarded Hydraulic powder compression press
- Flow property / unit: Number of items / item
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_equipment.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_equipment`
- Sources: `daikin-ptfe-moulding-2019`; `jrc-ilcd-2010`

###### Discarded Electric resistance batch sintering oven (`oven_equipment_waste`)

Only actual complete retired machine handover; retain physical unit, composition, historical per-exchange vector and receiver. No automatic scrap credit. Disassembly into separately handled materials requires each real atomic output; this card cannot conceal that disassembly.

- Selected flow: Discarded Electric resistance batch sintering oven
- Flow property / unit: Number of items / item
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_equipment.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_equipment`
- Sources: `daikin-ptfe-moulding-2019`; `jrc-ilcd-2010`

###### Discarded CNC dry-machining lathe (`lathe_equipment_waste`)

Only actual complete retired machine handover; retain physical unit, composition, historical per-exchange vector and receiver. No automatic scrap credit. Disassembly into separately handled materials requires each real atomic output; this card cannot conceal that disassembly.

- Selected flow: Discarded CNC dry-machining lathe
- Flow property / unit: Number of items / item
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_equipment.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_equipment`
- Sources: `daikin-ptfe-moulding-2019`; `jrc-ilcd-2010`

##### Elementary flows

###### Actual water vapour (`vapour`)

Native Elementary/Mass/kg, CAS7732-18-5, emission to air unspecified. Conditional actual evaporative loss; not liquid return, purchased steam, chemically bound water or invented sintering reaction water. Broad native water synonyms do not establish other phases/isotopes. Match an actually known compartment separately.

- Selected flow: water vapour `fe0acd60-3ddc-11dd-ac04-0050c2490048`
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_water.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_water`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`

###### Actual refrigerant leak (`r134a_leak`)

Conditional actual CAS811-97-2 loss to the verified air compartment, independently reconcile equipment charge and measured service recovery; missing kilograms are not automatically all atmospheric leak. No UUID adopted and no Chinese synonym represented as official baseName.

- Selected flow: 1,1,1,2-Tetrafluoroethane to air
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_charge.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_charge`
- Sources: `daikin-ptfe-moulding-2019`; `daikin-ptfe-m17-2016`

### Process: Actual post-release FG services (`service`)

#### Inputs

##### Product flows

###### Corrugated shipping carton received (`carton_in`)

Actual whole corrugated transport carton with verified composition/provider; no generic packaging UUID adopted. Record actual purchased quantity and external returns received separately, supplier-included package without a second purchase. Reconcile b_packages with disjoint empty/attached-WIP/FG/reusable stocks, internal reuse cancelled and original exchange vectors carried once.

- Selected flow: Corrugated shipping carton
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_packaging.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_packaging`
- Sources: `daikin-ptfe-moulding-2019`; `jrc-ilcd-2010`

###### LDPE protective bag received (`bag_in`)

Actual individual LDPE gasket bag with declared additive/composition limits; no bag assumed mandatory. Record actual purchased quantity and external returns received separately, supplier-included package without a second purchase. Reconcile b_packages with disjoint empty/attached-WIP/FG/reusable stocks, internal reuse cancelled and original exchange vectors carried once.

- Selected flow: LDPE protective bag
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_packaging.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_packaging`
- Sources: `daikin-ptfe-moulding-2019`; `jrc-ilcd-2010`

###### BOPP acrylic carton-sealing tape received (`tape_in`)

Actual supplied BOPP/acrylic tape as one whole purchased article; backing and adhesive only subaccounts. Record actual purchased quantity and external returns received separately, supplier-included package without a second purchase. Reconcile b_packages with disjoint empty/attached-WIP/FG/reusable stocks, internal reuse cancelled and original exchange vectors carried once.

- Selected flow: BOPP acrylic carton-sealing tape
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_packaging.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_packaging`
- Sources: `daikin-ptfe-moulding-2019`; `jrc-ilcd-2010`

###### Reusable wooden pallet received (`pallet_in`)

Actual identified wood pallet, retain ownership, repair components, reusable stocks and historical burden; no assumed service life. Record actual purchased quantity and external returns received separately, supplier-included package without a second purchase. Reconcile b_packages with disjoint empty/attached-WIP/FG/reusable stocks, internal reuse cancelled and original exchange vectors carried once.

- Selected flow: Reusable wooden pallet
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_packaging.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_packaging`
- Sources: `daikin-ptfe-moulding-2019`; `jrc-ilcd-2010`

###### Incremental FG service electricity (`service_electricity`)

Same native CN user-side grid-average below1kV Product/Net-calorific-value/MJ limits as utilities electricity. Meter only actual post-release handling, storage, packing and returned-gasket inspection; original production travels as historical vector, never charged again. Use the original cohort release Q and disclose service interval completeness.

- Selected flow: Alternating current `50657322-939c-4829-a87b-47c093bfa6a7`
- Flow property / unit: Net calorific value `93a60a56-a3c8-11da-a746-0800200c9a66` / MJ
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_service.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_service`
- Sources: `teadit-ptfe-gaskets-2023`; `jrc-ilcd-2010`

##### Waste flows

##### Elementary flows

#### Outputs

##### Product flows

###### Corrugated shipping carton outward custody (`carton_out`)

Actual whole corrugated transport carton with verified composition/provider; no generic packaging UUID adopted. Record packages on gross physical shipments and outward returns separately; this is custody movement, not coproduct production. Reconcile b_packages with disjoint empty/attached-WIP/FG/reusable stocks, internal reuse cancelled and original exchange vectors carried once.

- Selected flow: Corrugated shipping carton
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_packaging.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_packaging`
- Sources: `daikin-ptfe-moulding-2019`; `jrc-ilcd-2010`

###### LDPE protective bag outward custody (`bag_out`)

Actual individual LDPE gasket bag with declared additive/composition limits; no bag assumed mandatory. Record packages on gross physical shipments and outward returns separately; this is custody movement, not coproduct production. Reconcile b_packages with disjoint empty/attached-WIP/FG/reusable stocks, internal reuse cancelled and original exchange vectors carried once.

- Selected flow: LDPE protective bag
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_packaging.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_packaging`
- Sources: `daikin-ptfe-moulding-2019`; `jrc-ilcd-2010`

###### BOPP acrylic carton-sealing tape outward custody (`tape_out`)

Actual supplied BOPP/acrylic tape as one whole purchased article; backing and adhesive only subaccounts. Record packages on gross physical shipments and outward returns separately; this is custody movement, not coproduct production. Reconcile b_packages with disjoint empty/attached-WIP/FG/reusable stocks, internal reuse cancelled and original exchange vectors carried once.

- Selected flow: BOPP acrylic carton-sealing tape
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_packaging.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_packaging`
- Sources: `daikin-ptfe-moulding-2019`; `jrc-ilcd-2010`

###### Reusable wooden pallet outward custody (`pallet_out`)

Actual identified wood pallet, retain ownership, repair components, reusable stocks and historical burden; no assumed service life. Record packages on gross physical shipments and outward returns separately; this is custody movement, not coproduct production. Reconcile b_packages with disjoint empty/attached-WIP/FG/reusable stocks, internal reuse cancelled and original exchange vectors carried once.

- Selected flow: Reusable wooden pallet
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_packaging.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_packaging`
- Sources: `daikin-ptfe-moulding-2019`; `jrc-ilcd-2010`

##### Waste flows

###### Corrugated shipping carton waste (`carton_waste`)

Actual whole corrugated transport carton with verified composition/provider; no generic packaging UUID adopted. Weigh actual package waste by receiver and contamination separately from product and other packages. Reconcile b_packages with disjoint empty/attached-WIP/FG/reusable stocks, internal reuse cancelled and original exchange vectors carried once.

- Selected flow: Waste Corrugated shipping carton
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_packaging.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_packaging`
- Sources: `daikin-ptfe-moulding-2019`; `jrc-ilcd-2010`

###### LDPE protective bag waste (`bag_waste`)

Actual individual LDPE gasket bag with declared additive/composition limits; no bag assumed mandatory. Weigh actual package waste by receiver and contamination separately from product and other packages. Reconcile b_packages with disjoint empty/attached-WIP/FG/reusable stocks, internal reuse cancelled and original exchange vectors carried once.

- Selected flow: Waste LDPE protective bag
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_packaging.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_packaging`
- Sources: `daikin-ptfe-moulding-2019`; `jrc-ilcd-2010`

###### BOPP acrylic carton-sealing tape waste (`tape_waste`)

Actual supplied BOPP/acrylic tape as one whole purchased article; backing and adhesive only subaccounts. Weigh actual package waste by receiver and contamination separately from product and other packages. Reconcile b_packages with disjoint empty/attached-WIP/FG/reusable stocks, internal reuse cancelled and original exchange vectors carried once.

- Selected flow: Waste BOPP acrylic carton-sealing tape
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_packaging.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_packaging`
- Sources: `daikin-ptfe-moulding-2019`; `jrc-ilcd-2010`

###### Reusable wooden pallet waste (`pallet_waste`)

Actual identified wood pallet, retain ownership, repair components, reusable stocks and historical burden; no assumed service life. Weigh actual package waste by receiver and contamination separately from product and other packages. Reconcile b_packages with disjoint empty/attached-WIP/FG/reusable stocks, internal reuse cancelled and original exchange vectors carried once.

- Selected flow: Waste Reusable wooden pallet
- Flow property / unit: Mass / kg
- Amount rule: Read the single stored normalization result in section8 for this exchange and cohort; collect undivided raw records using cp_packaging.
- Value mode: `calculated_value`
- Specificity: `site_specific`
- Normalization basis: per 1 kg reference flow
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_packaging`
- Sources: `daikin-ptfe-moulding-2019`; `jrc-ilcd-2010`

##### Elementary flows

## 7. Allocation and Co-product Handling

| rule_id | Applies to | Rule | source_ids |
| --- | --- | --- | --- |
| a_scope | all allocation rules | The following hierarchy is conditional on an actual allocation-required attributional situation. Manufacturing-source capability is not LCA allocation evidence. | jrc-ilcd-2010 |
| a_subdivide | allocation-required attributional cases | First independently assign dedicated lots/materials/meters and real or virtual subdivision. Do not turn a mixed oven into one uniform mass factor: identify each batch function, actual load geometry and time-temperature heat demand, standby/extraction and other causal demands. Keep service burden attached to its actual released cohort. | jrc-ilcd-2010 |
| a_physical | remaining shared exchanges | For each still-shared exchange establish a determining physical causal relationship to each co-function and quantify its actual extent; evidence it separately for electric heat, machine drive, extraction, water and other streams. Mere mass correlation, nominal power, production value or arbitrary physical/economic choice is insufficient. | jrc-ilcd-2010 |
| a_residual | only genuinely residual allocation | Only genuinely unallocated remainder after subdivision and exchange-specific determining physical causality uses co-function market value at the common process gate in its actual condition and the same representative period. Record quantities/prices/quality/state, gate consistency, uncertainty and sensitivity; not retail finished-gasket prices versus wet-scrap prices at another gate. No fixed fraction or automatic recycling/substitution credit. Waste treatment service and an accepted coproduct require explicit separate status and burdens. | jrc-ilcd-2010 |
| asset_manufacture_conservation | existing capital/reusable manufacture attribution | Within the applicable allocation decision context, original manufacture burden attributed across uses of actual capital equipment or reusable articles already included in foreground production, packaging or observed services uses one persistent same-asset ledger across all crops, products, cohorts, manufacturing/postrelease services, owners and observation periods. D is its supported whole installed service: all realized historical service plus supported remaining service in the same units as actual beneficiary use u; D must be finite and positive. Period capacity, remaining-only capacity, the physical asset/article mass alone, or current-period product Q alone is not D; supported whole-service throughput in mass units may be used when it demonstrates the causal service and matches u. This does not amortize the manufactured reference product over downstream life or change its declared reference gate/Q. The fractions u/D and all previously assigned manufacture shares together must never exceed 1. Changes of window, custody, provider or repair never restart the original manufacture balance. Replacements have distinct identities and only their real new manufacture vectors; actual repair and treatment increments remain separately accounted. Revised capacity evidence requires transparent reconciliation of prior shares and sensitivity, not a fresh ledger. Keep full physical mass and stock movements independent of burden shares. Unknown D, prior shares or beneficiary coverage requires review and no final manufacture-attributed amount; no assumed lifetime, utilization, zero or arbitrary division is permitted. For each existing collection protocol that attributes manufacture of included production, packaging or observed-service assets across uses in this route (excluding amortization of the manufactured reference product itself), additionally retain a durable asset identity, its measured full physical mass and acquisition/installation/retirement stock history, original manufacture burden vector, all historical and current beneficiaries, matched-unit service readings, the evidenced whole installed-service denominator D, supported remaining-service basis and uncertainty, prior assigned shares and remaining original manufacture balance. Carry the ledger across reporting windows and custody/provider changes. Collect actual repair, replacement, recovery and treatment separately; these records do not normalize physical movements or create an additional asset purchase. These are added fields and conservation obligations for the existing applicable protocols, not a new assumed capital inventory. |  |

## 8. Foreground Data Collection, Calculation, and Quality Rules

Protocols collect undivided raw records. aggregation_rule states only the final target basis; it performs no division. Cards and aggregation read the same stored calc_normalize_once result. No source supplies actual site quantities.

### Data Collection Protocols

For each existing collection protocol that attributes manufacture of included production, packaging or observed-service assets across uses in this route (excluding amortization of the manufactured reference product itself), additionally retain a durable asset identity, its measured full physical mass and acquisition/installation/retirement stock history, original manufacture burden vector, all historical and current beneficiaries, matched-unit service readings, the evidenced whole installed-service denominator D, supported remaining-service basis and uncertainty, prior assigned shares and remaining original manufacture balance. Carry the ledger across reporting windows and custody/provider changes. Collect actual repair, replacement, recovery and treatment separately; these records do not normalize physical movements or create an additional asset purchase. These are added fields and conservation obligations for the existing applicable protocols, not a new assumed capital inventory.

| protocol_id | process_id | flow_role | record_type | raw_fields | collection_method | unit | frequency | temporal_coverage | site_scope | aggregation_rule | quality_evidence |
| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |
| cp_material | prepare | whole powder | foreground_record | supplier; grade; whole supplied form; CAS; original quantity/unit; particle form; moisture; invoices; opening/closing raw and each WIP stage; inherited exchange vectors | Weigh/tare whole supplied powder and actual stocks; verify conventional granular homopolymer and contamination. Store raw values without division; retain supplier-included constituents as subaccounts. | kg | each lot and stock cut-off | complete declared cohort/period with relevant opening history | actual site; each lot/equipment/circuit/receiver | per 1 kg reference flow | original calibrated records; independent identity/state and vector reconciliation |
| cp_release | machine | unique first release | foreground_record | cohort; drawing; lot; serial release event; bare net kg; tare; count; moisture; conditioning; acceptance specification and actual tests; original Q | Use calibrated weighing of bare accepted gaskets or count-verified homogeneous lots, excluding packaging. Sum unique NEW first-release net kg as Q. Keep reinspection/return separate. Count-to-kg uses measured configuration-specific net mass, never density or a guessed item weight. | kg | each acceptance and cohort close | complete declared cohort/period with relevant opening history | actual site; each lot/equipment/circuit/receiver | per 1 kg reference flow | original calibrated records; independent identity/state and vector reconciliation |
| cp_energy | utilities | actual manufacturing electric load | foreground_record | meter; raw start/end kWh; actual power/time only if rate; batch geometry; programme; ramps/holds/cooling; idle/startstop/failed/cleanup; causal allocation; utility inclusions | Meter differences without division; integrate actual power rates once with matching time units. Independent process meters/engineering establish allocation, not nameplate times nominal throughput. Convert kWh to MJ once at numerator stage. | kWh | continuous and every complete run | complete declared cohort/period with relevant opening history | actual site; each lot/equipment/circuit/receiver | per 1 kg reference flow | original calibrated records; independent identity/state and vector reconciliation |
| cp_water | utilities | each physical water circuit | foreground_record | supply; return; bleed; condensate; vapour; free/reaction/phase water; raw volumes; total/rate flag; independent density at state; temperature/enthalpy; solutes; FG moisture; opening/closing loop stock/vector; supplier agreement | Independently meter/weigh actual streams and stock. Convert integrated volume using this material density at its actual state; integrate only true rates. Record measured species and water independently; preserve external return as Product where applicable. | kg | each circuit interval and stock cut-off | complete declared cohort/period with relevant opening history | actual site; each lot/equipment/circuit/receiver | per 1 kg reference flow | original calibrated records; independent identity/state and vector reconciliation |
| cp_charge | utilities | oil/refrigerant/filter equipment service | foreground_record | equipment/charge; whole preparation; original raw quantity/unit; opening/closing charge mass and per-exchange vector; top-up; consumption; recovery; external return; waste; leak; filter media/housing/retained dust; service duration | Weigh actual service movements and charges and independently verify receiver/chemistry. Keep actual gross acquired mass, actual outward recovery/unused transfers, spent waste and independently measured leaks distinct from the service-burden vector. Retain disjoint non-WIP physical stocks and every inherited exchange vector. Use independently measured consumption or a proved equivalent stock/vector correction once, not both. An unused outward transfer carries only its evidenced remaining vector; spent oil/filter, leakage or treatment-bound discharge does not automatically cancel the upstream burden already consumed in service. Do not subtract every physical outward quantity as unused return or reduce a real acquisition/waste/leak card by allocation. Retain original stock lineage, actual composition/assay, service attribution and additional handling/treatment burdens separately; no missing mass is automatically an air emission. | kg | each service event and cut-off | complete declared cohort/period with relevant opening history | actual site; each lot/equipment/circuit/receiver | per 1 kg reference flow | original calibrated records; independent identity/state and vector reconciliation |
| cp_air | utilities | external compressed air | foreground_record | actual supplier; original total/rate volume; pressure; temperature; humidity; reference conditions; energy inclusion; leaks | Preserve metered reference-state volume and source-specific state correction. Do not multiply integrated volume by duration; internal generation cancels with real own utilities retained. | m3 | each actual interval | complete declared cohort/period with relevant opening history | actual site; each lot/equipment/circuit/receiver | per 1 kg reference flow | original calibrated records; independent identity/state and vector reconciliation |
| cp_waste | machine | each specific waste | foreground_record | stream; preform/sintered state; source lot; raw wet/dry mass; moisture; contamination; handler; actual recovery/disposal; retained polymer and inherited vectors | Weigh each actual physical waste stream and split captured powder, sintered turnings, failed articles and composite filter waste; reconcile independently with raw/WIP and physical mass. Internal reuse is a transfer retaining energy/losses. | kg | each transfer and closing stock | complete declared cohort/period with relevant opening history | actual site; each lot/equipment/circuit/receiver | per 1 kg reference flow | original calibrated records; independent identity/state and vector reconciliation |
| cp_emission | form | actual individually identified species | foreground_record | species; CAS; molecular identity; source event; air compartment; stack/fugitive; original concentration and gas total/rate volume; pressure/temperature/humidity; time only for rate; capture; measured water and C/F balance | Use independent analytical identity and calibrated species-specific mass; integrated gas volume times compatible concentration once, time only if a true rate. Keep precursor and downstream hydrolysis species at their true gates, not duplicated. Total fluoride/VOC/COD cannot stand for a particular molecule. Missing coverage remains unknown. | kg | representative full runs including failures | complete declared cohort/period with relevant opening history | actual site; each lot/equipment/circuit/receiver | per 1 kg reference flow | original calibrated records; independent identity/state and vector reconciliation |
| cp_packaging | service | each named package and destination | foreground_record | article; composition; provider; original count and measured kg; purchases; included supply; external returns received; gross shipment outward; external return sent; waste; disjoint opening/closing empty/attached-WIP/FG/reusable stocks and every historical vector; repair old/new masses | Weigh/tare actual single articles or homogeneous lots and reconcile b_packages separately for each material. Keep original burden once and physical gross directions; internal reuse is not another purchase. A real repair component and its old waste require separate rows and historical vectors. | kg | every purchase/movement/repair and stock cut-off | complete declared cohort/period with relevant opening history | actual site; each lot/equipment/circuit/receiver | per 1 kg reference flow | original calibrated records; independent identity/state and vector reconciliation |
| cp_service | service | original-cohort incremental services | foreground_record | original cohort Q; service interval; undivided meter data; opening/closing FG kg/moisture and production/service vectors; gross dispatch; original delivery reversal; returns; inspection/repair; real new/old component mass and vectors; service-WIP/non-WIP | Retain raw physical custody and actual incremental load. Original burden follows the original gasket once; reinspection/repair is not new production. Keep original-delivery reversals and actual replacement/new-component-old-waste vectors; materially changed product requires applicability review. Disclose incomplete services. | kWh | every movement/service interval | complete declared cohort/period with relevant opening history | actual site; each lot/equipment/circuit/receiver | per 1 kg reference flow | original calibrated records; independent identity/state and vector reconciliation |
| cp_freight | prepare | actual inbound road service | foreground_record | origin; destination; actual load mass tonnes; actual loaded distance km; mode; route; vehicle; empty leg; provider inclusions | Collect whole shipment transport service using actual t times actual km once before allocation; preserve original records and any supplier inclusion. Other actual modes require atomic rows. | tkm | each shipment | complete declared cohort/period with relevant opening history | actual site; each lot/equipment/circuit/receiver | per 1 kg reference flow | original calibrated records; independent identity/state and vector reconciliation |
| cp_equipment | utilities | each durable press/oven/lathe | foreground_record | machine identity; composition; disjoint opening/closing in-service physical units N0/N1; actual gross acquisitions N_in; external returned acquisitions; actual outward Product handovers N_out; complete retirements N_retired; actual repair additions/removed parts; original and remaining upstream per-exchange vectors; separately evidenced service-demand vector allocated to each first-release cohort or later service interval; capital boundary | Keep raw physical counts and service-burden vectors as distinct linked ledgers. For the same complete-machine identity close N0 + actual gross acquisitions + actual external returns received = N1 + actual Product handovers outward + actual complete retirements, with other actual directions separately named and internal movements cancelled. Do not reduce a retained physical machine because some upstream burden was assigned to service, and do not reduce a genuine acquisition count by a service fraction. Under the disclosed capital boundary, attribute actual service per exchange using evidenced demand and original/remaining stock history once, separately from acquisitions and actual repair parts/removed parts. Link each service allocation to either manufacturing first release or a later original-cohort interval; never repurchase old assets or re-charge already assigned history. Item(s) and item are the same count unit with factor1; no guessed kg/machine, lifetime, equal repair mass or default depreciation. | item | each event and reporting cut-off | complete declared cohort/period with relevant opening history | actual site; each lot/equipment/circuit/receiver | per 1 kg reference flow | original calibrated records; independent identity/state and vector reconciliation |

### Calculation Rules

| rule_id | Applies to | Formula or rule | Inputs | Output | source_ids |
| --- | --- | --- | --- | --- | --- |
| calc_q | finished_gasket | Q = sum of unique NEW first-quality-release bare net kg from cp_release; exclude repeat inspection, return and dispatch; include measured actual retained moisture consistently. Closing FG is already part of Q. | cp_release; cohort_id | Q | teadit-ptfe-gaskets-2023 |
| calc_normalize_once | all inventory rows | For Q > 0, z_i_c = A_i_c / Q once. Before this sole division convert original numerator units/states and integrate only true rates, then apply evidenced assignment/allocation. Manufacturing burden vectors retain attributable current loads plus opening minus closing disjoint unreleased raw/WIP and eligible non-WIP historical vectors, corrected once. Never subtract closing FG production vectors: every newly first-released gasket is already in Q even if still stored; prior released opening FG is not new current production. Service burden vectors retain only original-cohort incremental service and eligible service-stock vectors, keeping assigned production history fixed. Physical acquisition, external return, gross shipment, emission and waste cards use actual direction quantities in their own mass, volume or item unit as A_i_c, independent of consumed-service burden allocation. In particular complete-machine inputs are actual gross acquisitions and retirement outputs actual handovers, not service-equivalent fractional machine purchases; retained old equipment can have zero acquisition and a positive independently attributed service vector. A newly acquired whole machine remains its actual acquired count even when only part of its upstream vector serves this cohort. Do not add gross acquisition-provider burdens and the same stock-attributed service vector twice; retain linked physical and burden views. Use independently measured consumption OR a proved equivalent lineage-specific stock/vector correction once, without subtracting all spent/leaked/wasted outward mass as unused transfer. Q for service is the original release cohort kg, never net dispatch or repair release. Cards and aggregation only read this same z_i_c, without another division. At Q=0 retain real loads, stocks and vectors and issue no unit result. | A_i_c; Q; cohort_id; service_interval | z_i_c | daikin-ptfe-moulding-2019; teadit-ptfe-gaskets-2023; jrc-ilcd-2010 |
| calc_units | all inventory rows | Original numerator conversions: g to kg uses0.001; t to kg uses1000; kWh to MJ uses3.6 from the verified native energy unit group. Use measured material-specific density at the independently documented state only for a real volume-to-mass conversion. Count-to-mass uses measured net lot mass/count of the same configuration. Integrated liquid/gas volume is not multiplied by time; true rates are integrated once. | raw_quantity; raw_unit; measured_state; measurement_record | converted_raw_quantity | daikin-ptfe-moulding-2019 |
| calc_physical | all physical gates | For each disjoint physical gate independently reconcile opening + actual external inputs = closing + actual external outputs + actual measured transformations; cancel internal transfers. Keep separate measured component/element balances and species-based reaction/water checks, including actual air/oxygen/water if a reaction consumes them. No residual-fitting two unknowns or equating polymer dust with monomer; add actual unlisted atomic exchanges before closure. | physical_stocks; measured_inputs; measured_outputs; independent_species; moisture | gate_balance | daikin-ptfe-moulding-2019; daikin-ptfe-m17-2016; teadit-ptfe-gaskets-2023 |
| calc_packages | all package rows | Apply b_packages to each single package identity with actual physical directions and disjoint stocks. Carry original vector once, record real new repair parts/old-part wastes, cancel internal reuse and never count packages in net gasket Q. | cp_packaging; package_id; opening_stock; closing_stock; physical_movements | package_balance | jrc-ilcd-2010 |
| asset_manufacture_share | existing capital/reusable manufacture attribution | For each included original asset manufacture vector B, f_current = u_current / D only after the persistent ledger verifies the supported whole installed-service denominator, all beneficiaries and prior assigned shares. Attribute f_current * B once to the actual beneficiary before the existing single reference normalization. Check prior_shares + all current/new beneficiary shares <= 1; carry the remaining original balance. Capacity revisions reconcile the historical ledger. Full physical asset/packaging mass and actual gross stocks/returns never receive f_current. Unknown D or history leaves the final attributed result unavailable, without suppressing actual repair/replacement/service burdens. | asset_id; original_B; u_current; D; historical_beneficiaries; prior_shares; capacity_evidence | conserved attributed manufacture vector |  |

### Data Quality Requirements

| requirement_id | Applies to | Requirement | Evidence |
| --- | --- | --- | --- |
| dq_identity | all bound and unbound rows | Verify all native names/synonyms/comments, CAS, form, route, geography, compartment, type, every property and exact referenced unit chain. Generic identity proves neither actual supplier compatibility nor quantitative data. Track unresolved auxiliary UUIDs without replacing an atomic exchange or automatic draft. | complete direct identity and supplier/measurement evidence |
| dq_programme | powder through release | Use actual grade/shape-dependent programmes and release testing; source example matrices, density, shrinkage and creep plots are not factory measurements or service certification. | actual programme/lot traces; calibration; drawing and independent specification |
| dq_complete | all ledgers | Retain zero-output, failed, idle, cleanup and rework; all WIP/FG and non-WIP physical/vector histories, raw numerator provenance, ordinary unresolved supplies and missing service/emission coverage. Unknown is not zero or pass. | raw meter and stock records; species evidence; uncertainty and coverage register |

## 9. Validation Rules

| rule_id | Applies to | Rule | source_ids |
| --- | --- | --- | --- |
| v_basis | reference and all rows | Exactly one finished_gasket Product output links the1kg reference. EN/ZH qualifiers, Q gate, rows, unit basis and one normalization agree. Collection stores undivided raw data; aggregation is the target label, not another operation. Q0 yields no unit result. | teadit-ptfe-gaskets-2023 |
| v_material | powder/forming/machining | Reject applying this method to a conflicting powder form, modified/filler/expanded polymer, altered hot-coining/isostatic/ram/skiving route or purchased finished article. Verify actual first release and scope; raw-to-product route must remain complete. | daikin-ptfe-moulding-2019; daikin-ptfe-m17-2016; teadit-ptfe-gaskets-2023 |
| v_native | native UUID bindings | Apply each entire card restriction. The seal generic name cannot infer rubber material from its classification or establish a36990 mapping. TFE monomer CAS116-14-3 cannot represent PTFE9002-84-0 dust; air-unspecified bindings are replaced by verified actual compartments when known. CN below1kV grid user-side supply only. Unresolved actual flow/provider/unit compatibility remains explicit. | daikin-ptfe-moulding-2019; daikin-ptfe-m17-2016; teadit-ptfe-gaskets-2023; doing-ptfe-oven |
| v_balance | manufacturing/FG/non-WIP/packages | Independently verify physical mass/element closure and actual species/reaction-water evidence. Reconcile every package direction/stock and non-WIP charge vector, inherited production/service separation, opening/closing WIP/FG moisture and actual repair new/old components. No duplicated closing-FG output, internal purchase, automatic coproduct or residual-fitted emission. | daikin-ptfe-moulding-2019; daikin-ptfe-m17-2016; jrc-ilcd-2010 |
| v_allocation | shared burden | Document the actual attributional allocation need, dedicated/virtual subdivision, exchange-specific determining causality and only genuinely residual common-gate same-state contemporaneous market values; no fixed physical/economic split or automatic credit. Missing scientific evidence or unsupported relationships remain pending review. | jrc-ilcd-2010 |
| validate_asset_manufacture_conservation | existing capital/reusable manufacture attribution | For every included capital/reusable manufacture attribution verify same-asset continuity, whole installed service in matched units, all historical/current beneficiaries, prior assigned manufacture shares and cumulative share <= 1. Reject a reset by period, cohort, provider, owner or repair. Check distinct real replacement and incremental repair/treatment vectors separately and preserve gross physical mass. A missing denominator, unexplained previous allocation or incomplete beneficiary ledger requires explicit review and an unavailable final attributed amount; structural inspection cannot claim empirical completeness. |  |

## 10. Published Dataset Profile

| Field | Value |
| --- | --- |
| dataset_role | secondary_dataset; background_dataset |
| downstream_use | Declared-unit upstream input to an actually compatible gasket/joint assessment |
| allowed_use | Configuration-compatible attributional manufacturing inventory with disclosed service interval |
| excluded_use | Universal plastic36990 coverage; sealing-service equivalence; oxygen/medical certification; automated mapping or methodology approval |
| required_metadata | All required qualifiers; actual geography/time, material/supplier and full route; single Q; distinct service coverage; source lineage |
| required_quality_disclosure | Uncertainty; actual sampling; failed/zero batches; WIP/FG/non-WIP vectors; native classification caveat; unresolved UUID/provider/compartment and service gaps |
| update_trigger | Material form/grade or route/application change; drawing/specification change; utilities, species or allocation evidence change |

## 11. Data Sources

| Source id | Type | Reference | Used for |
| --- | --- | --- | --- |
| daikin-ptfe-moulding-2019 | handbook | Daikin, POLYFLON PTFE Molding Powder, 10/19 EGE-11b DCEPN; https://www.daikinchem.de/wp-content/uploads/2024/08/Product-Brochure-POLYFLON-PTFE-M.pdf | Conventional powder/compression/free-bake/cooling context pp2–13; adjacent modified grades/other routes pp13–25; application/caution pp26–28. Example figures/programmes are not defaults; warning HCl is not proof of chlorine in pure PTFE. |
| daikin-ptfe-m17-2016 | handbook | Daikin, PTFE M-17 TDS-PTFE-M-007 REV0 2/9/16; https://www.daikinchemicals.com/library/pb_common/pdf/tds_us/Fluoropolymers/PTFE-M/TDS_PTFE_M_007Rev.0_M_17_.pdf | Whole virgin granular fine-cut compression-powder supply, agglomeration/handling and thermal fume context; typical properties not a specification or adopted numbers. |
| teadit-ptfe-gaskets-2023 | literature | Florian Werner, TEADIT, Extreme Differences in PTFE Flat Gaskets, Valve World Americas August2023 pp10–11; https://teadit.com/wp-content/uploads/2023/08/VWAM_August2023_Pgs-10-11_Special-Topic_Florian-Werner_HR.pdf | Compression/sinter/cool/direct-machining sealing endpoint; structured/expanded counterroutes; specific PQR/torque tests not transferred to actual products. |
| doing-ptfe-oven | handbook | Changzhou Doing Machine, PTFE Sintering Oven, retained publisher snapshot2026-10-20; https://www.doing-machine.com/ptfe-sintering-oven | Electric resistance batch-oven/air circulation/exhaust capability and fuel alternatives; nominal model powers are not consumption; machinery plywood packing is not gasket packaging. |
| jrc-ilcd-2010 | official_guidance | European Commission JRC, ILCD Handbook General guide for LCA Detailed guidance, first edition March2010, §§7.9.2–7.9.3 especially printed257–258; https://eplca.jrc.ec.europa.eu/uploads/ILCD-Handbook-General-guide-for-LCA-DETAILED-GUIDANCE-12March2010-ISBN-fin-v1.0-EN.pdf | Allocation-required attributional hierarchy, virtual subdivision and exchange-specific determining physical causality; genuinely residual actual-condition common-gate market value; not an industrial powder recipe. |
| un-cpc3-2025 | official_guidance | UNSD CPC Ver.3.0 Structure30Jun2025, retained original CPC_Ver_3.0_Structure_30Jun2025.csv; https://unstats.un.org/unsd/classifications/Econ/Download/In%20Text/CPC_Ver_3.0_Structure_30Jun2025.csv | Original36990 and surrounding363/364/369/371 classification labels only; no manufacturing rule or accepted mapping. |