pcr_id: pcr.metal-products-machinery-and-equipment.special-purpose-machinery.industrial-knitting-machinery
language: en-US
status: candidate
sync_with: pcr.zh-CN.md
---

# Industrial single-jersey circular knitting machinery manufacture

## 1. Scope and Applicability

This PCR covers manufacture of complete large-diameter single-jersey circular weft-knitting machines with declared diameter, gauge, needle/sinker mechanism, yarn feeding, drive, take-down and controls. Distinguish conventional and relative/spring-sinker layouts and actual delivered accessories. Include the complete configured machine at acceptance, with installed knitting tools, guard/frame, drive/control, feed/take-down modules and declared delivered creel. Exclude warp knitting, flat knitting, double-jersey/dial machines, seamless individual-item/hosiery machines, stitch-bonding, gimp/lace/embroidery/braid/net/tufting machines, looms and separately sold parts. CPC 44613 is broader than this boundary. Textile manufacturing in the customer mill, routine yarn consumption, fabric yield, mill utilities, maintenance/replacement needles and end-of-life are outside this manufacturing inventory. Actual factory knitting trials, test yarn, trial fabric handling and attributable utilities/lubricant/waste belong to manufacture. No textile production service or operating lifetime is included.

## 2. Product Category Identity

| Field | Value |
| --- | --- |
| canonical_pcr_id | pcr.metal-products-machinery-and-equipment.special-purpose-machinery.industrial-knitting-machinery |
| classification_refs | CPC 3.0 44613; narrower category context, not an accepted mapping |
| covered_products | Complete configured large-diameter single-jersey circular weft-knitting machines |
| excluded_products | Warp/flat/double-jersey/hosiery knitting; looms; other CPC44613 mechanisms and spare parts |
| representative_product | One complete accepted clean unloaded configured knitting machine |
| production_route | Receive steel stock or finished modules; actual frame fabrication and conditional finishing; cylinder/needle/sinker/cam and feeder/drive/control/take-down assembly; factory trial and acceptance |
| market_state | New accepted complete machine at factory gate, without yarn cones or trial fabric; packaging separately inventoried |

## 3. Reference Flow

| Field | Value |
| --- | --- |
| What | Provide the declared single-jersey circular weft-knitting machine |
| How much | 1 kg of the same complete accepted configured machine using measured net mass M |
| How well | Meet actual drawings and configuration-specific factory acceptance criteria. Record needle/sinker alignment, cam timing, feeder tension, drive/interlocks, lubrication, take-down and actual trial-loop/defect inspection with the declared test yarn, duration and calibrated instruments. Brochure speed, fabric production rate, efficiency, energy/CO2 savings and life claims do not prescribe generic factory quantities or acceptance limits. |
| How long or cycle | One manufacturing delivery; no assumed knitting service life or fabric-production cycle |
| reference_flow_link | finished_machine |

| Field | Value |
| --- | --- |
| Reference amount | 1 |
| Reference product flow | Knitting machines, stitch-bonding machines, machines for making gimped yarn, tulle, lace, embroidery, trimmings, braid or net and machines for tufting `533238d4-94ee-4db4-8e64-cfe66821248f` |
| Reference flow property | Mass `93a60a56-a3c8-11da-a746-0800200b9a66` |
| Reference unit group | Units of mass `93a60a57-a4c8-11da-a746-0800200c9a66` |
| Reference unit | kg |
| Required qualifiers | model/serial or batch; diameter/gauge; needle tracks and sinker layout; installed needle/sinker counts and grade/state; cylinder/cam/feeder/drive/take-down/control; delivered creel/guard/accessory and electronics inclusion; clean unloaded state without yarn/fabric; retained lubricant; measured M; factory/site and period; input gates; test yarn, trial duration and inspection; actual covered stages |

Weigh the same complete accepted delivery configuration on calibrated scales. Packing/shipping gross weight, nominal catalogue weight or a machine loaded with yarn/cloth does not replace M. Needle and sinker counts identify configuration; actual installed batch mass contributes to M without an assumed unit-piece weight. Kilogram normalization does not establish equivalent fabric-making performance across gauges, layouts or products.

## 4. Measurement and Unit Rules

| rule_id | Applies to | Required property | Required unit | Rule |
| --- | --- | --- | --- | --- |
| `reference_mass` | reference product | Mass `93a60a56-a3c8-11da-a746-0800200b9a66` | kg | M = accepted net mass of one complete machine of the same configuration in kg; collect using cp_mass. |
| `energy_units` | electricity rows | Net calorific value `93a60a56-a3c8-11da-a746-0800200c9a66` | MJ | Preserve the meter unit; convert kWh to MJ using exactly 1 kWh = 3.6 MJ. Do not interpret the electricity property name as a combustion inventory. |
| `volume_units` | groundwater rows | Volume `93a60a56-a3c8-22da-a746-0800200c9a66` | m3 | Retain measured volume and its conditions; do not invent gas density, water density or calorific value to switch to mass or energy. |

## 5. System Boundary

### Boundary Abstraction

| Field | Value |
| --- | --- |
| declared_starting_condition | Materials and configured components received at declared supplier gates, with no implicit upstream steelmaking or component fabrication in foreground |
| starting_condition_role | Manufacturing input boundary for an accepted complete machine |
| product_classification_scope | Large-diameter single-jersey circular weft-knitting machines within CPC 44613 context |
| recursive_input_rule | A purchased complete machine used as an input is a separately declared upstream product. Do not recursively regenerate this category; distinguish new production from refurbishment. |
| upstream_dataset_requirement | Link input-specific upstream datasets matching material, finished-component gate, geography, voltage and treatment state. Missing links remain disclosed coverage gaps. |
| disclosure | Report foreground factory stages, outsourced operations, component content, incoming transport coverage, protective packaging gate, capital-equipment policy and every exclusion; no complete cradle-to-gate claim without verified upstream and logistics closure. |

| rule_id | applies_to | rule | source_ids |
| --- | --- | --- | --- |
| `manufacturing_gate` | foreground | Include every actual operation and attributable rework from declared received inputs through factory acceptance; distinguish purchased parts from site fabrication to prevent duplication. Use documented route records. |  |
| `conditional_finish` | finishing | Activate only documented finishing operations and chemical recipes. Manufacturer examples establish possible routes, not universal requirements or recipes. |  |
| `exclude_mill_production` | textile_use | Exclude customer-mill production, routine yarn/fabric output, mill utilities and maintenance/disposal. Include actual factory trials and their material/energy/waste; no textile production service is included. |  |

## 6. Process Inventory Structure

### Process Map

| process_id | process_name | inclusion | inclusion_condition | role | quantitative_reference |
| --- | --- | --- | --- | --- | --- |
| `forming` | Stock cutting, forming and machining | conditional | Only when the site fabricates these parts; otherwise record purchased finished parts separately | foreground manufacturing | per 1 kg reference flow; collected per one accepted finished machine |
| `joining` | Structural welding and dressing | conditional | Only when the site joins structural parts by welding | foreground manufacturing | per 1 kg reference flow; collected per one accepted finished machine |
| `wet_surface` | Aqueous cleaning and preparation | conditional | Only when aqueous cleaning or conversion treatment is actually performed; activate individual rows from the documented recipe | foreground manufacturing | per 1 kg reference flow; collected per one accepted finished machine |
| `powder_finish` | Powder application and curing | conditional | Only when actual finishing uses powder; electrical curing rows only for actual electrically cured powder | foreground manufacturing | per 1 kg reference flow; collected per one accepted finished machine |
| `assembly` | Configured machinery assembly | required | Every accepted complete machine; activate component rows only when actually installed | foreground manufacturing | per 1 kg reference flow; collected per one accepted finished machine |
| `acceptance` | Factory acceptance and net-mass determination | required | Every accepted complete machine | foreground manufacturing | per 1 kg reference flow; collected per one accepted finished machine |
| `packaging` | Shipment protection at factory gate | conditional | Only when shipment protection is inside the declared delivery gate; disclose its exclusion otherwise | foreground manufacturing | per 1 kg reference flow; collected per one accepted finished machine |

Process records are separate contributors to one final accepted output, not seven separately traded reference products. Retain traceable internal-part transfer and bill-of-material records; internal transfers cancel within this foreground and do not receive duplicated upstream burdens. The cards below are explicit route-conditioned exchanges. Add each actual additional part, chemical, fuel, packaging piece, wastewater stream or measured elementary substance as its own identified row; absence of a card is not a cut-off permission. For outsourced finishing, replace site chemistry and energy with the exact purchased service or finished-part record and disclose its coverage.

### Process: Stock cutting, forming and machining (`forming`)

#### Inputs

##### Product flows

###### Hot-rolled non-alloy steel sheet (`steel_sheet`)

Include only sheet stock actually issued for the machine base or guard frame. Record grade, width, thickness and incoming surface treatment; weigh issued stock less unopened returns. The confirmed stock identity remains unresolved; do not substitute contradictory alloy/non-alloy records.

- Selected flow: Hot-rolled non-alloy steel sheet
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_forming.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_forming`

###### Alternating current (`forming_electricity`)

Meter cutting, drilling, bending and machining performed on site, including attributable extraction equipment. This UUID applies only to grid-average user-side 1–35 kV supply at the purchased gate; internal low-voltage use is not another purchased input. Other supply conditions require another verified identity.

- Selected flow: Alternating current `3d76981f-964a-4865-b588-0e067a2a1163`
- Flow property / unit: Net calorific value `93a60a56-a3c8-11da-a746-0800200c9a66` / MJ
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_forming.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_forming`

#### Outputs

##### Waste flows

###### Post-industrial steel scrap (`steel_offcut`)

Weigh segregated steel offcuts leaving the factory untreated. Record alloy fractions and destination; internal reuse is not an exported waste and oily swarf needs its own row.

- Selected flow: Post-industrial steel scrap `c143745d-be4f-4d8f-b403-2dcbfe685349`
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_forming.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_forming`

### Process: Structural welding and dressing (`joining`)

#### Inputs

##### Product flows

###### Flux Cored Wire (`flux_wire`)

Only for documented all-position single-pass self-shielded flux-cored carbon-steel welding consistent with this identity. Weigh consumed wire by spool issue and return; other welding consumables are separately identified, not substituted into this row.

- Selected flow: Flux Cored Wire `1b74a576-06e0-4764-97ce-11a73f8a4752`
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_joining.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_joining`

###### Copper-coated solid carbon-steel welding wire (`solid_wire`)

Only for the documented solid-wire route. Record wire designation and consumed mass; do not apply the flux-cored wire UUID.

- Selected flow: Copper-coated solid carbon-steel welding wire
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_joining.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_joining`

###### Argon gas for welding (`argon`)

Only when pure argon is actually supplied and consumed; cylinder net mass records establish quantity. An argon/carbon-dioxide blend is a different formulated gas and must be a separate row with its composition.

- Selected flow: Argon gas for welding
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_joining.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_joining`

###### Alternating current (`joining_electricity`)

Meter welding, weld dressing and extraction equipment; apply the same purchased supply condition as forming_electricity. Do not count the common factory meter twice.

- Selected flow: Alternating current `3d76981f-964a-4865-b588-0e067a2a1163`
- Flow property / unit: Net calorific value `93a60a56-a3c8-11da-a746-0800200c9a66` / MJ
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_joining.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_joining`

### Process: Aqueous cleaning and preparation (`wet_surface`)

#### Inputs

##### Product flows

###### Sodium hydroxide cleaning reagent, supplied concentration declared (`caustic`)

Only if the actual cleaning recipe uses sodium hydroxide. Collect supplied solution mass and concentration without treating it as pure substance mass; 95–98% grade identity is not applied to unknown-concentration baths. Each additional cleaning chemical needs its own atomic row.

- Selected flow: Sodium hydroxide cleaning reagent, supplied concentration declared
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_wet_surface.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_wet_surface`

###### Process Water (`supplied_water`)

Purchased process water for washing and rinsing only; weigh or obtain supplier water mass records. Record treatment state and supplier gate; never identify this technosphere input as a water resource or count the supplier extraction again.

- Selected flow: Process Water `94a04f7e-2d5c-41f0-b182-d54a3b373a02`
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_wet_surface.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_wet_surface`

###### Alternating current (`wet_electricity`)

Meter bath circulation, rinsing and water treatment within the declared boundary, under the purchased supply condition already stated.

- Selected flow: Alternating current `3d76981f-964a-4865-b588-0e067a2a1163`
- Flow property / unit: Net calorific value `93a60a56-a3c8-11da-a746-0800200c9a66` / MJ
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_wet_surface.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_wet_surface`

##### Elementary flows

###### ground water (`well_water`)

Only for groundwater abstracted directly by this foreground site for its baths and rinses. Meter gross abstraction in m3 and identify country and well; Resources / Resources from water / Renewable material resources from water. No scarcity class is asserted. Do not also record the same water as purchased process water.

- Selected flow: ground water `4f462198-40cd-4184-8733-86648a20dc3f`
- Flow property / unit: Volume `93a60a56-a3c8-22da-a746-0800200c9a66` / m3
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_wet_surface.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_wet_surface`

#### Outputs

##### Waste flows

###### Spent aqueous alkaline cleaning solution (`alkaline_effluent`)

Only when this single liquid waste stream leaves the boundary. Measure solution mass, pH and constituents and identify receiving treatment; it is a waste transfer, not an elementary water emission.

- Selected flow: Spent aqueous alkaline cleaning solution
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_wet_surface.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_wet_surface`

### Process: Powder application and curing (`powder_finish`)

#### Inputs

##### Product flows

###### Powder Coating (`powder`)

For the actual dry powder formulation only. Reconcile fresh powder and external returns with recovered powder circulation; do not count internal recirculation as another purchased input. Record binder and colour, without assuming polyester.

- Selected flow: Powder Coating `6e3010f9-fbd3-48f6-95fc-c1b38d2800d2`
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_powder_finish.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_powder_finish`

###### Alternating current (`powder_electricity`)

Meter powder application, compressed-air generation attributable to this operation and electrically heated curing when present, with the stated purchased supply condition.

- Selected flow: Alternating current `3d76981f-964a-4865-b588-0e067a2a1163`
- Flow property / unit: Net calorific value `93a60a56-a3c8-11da-a746-0800200c9a66` / MJ
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_powder_finish.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_powder_finish`

#### Outputs

##### Waste flows

###### Powder coating waste (`powder_residue`)

This identity applies only to dry overspray at a Chinese plant; other geography needs a separately verified identity. Weigh only collected dry overspray exported as waste; reclaimed powder reused internally is excluded. Keep solid powder separate from wastewater or liquid primer sludge.

- Selected flow: Powder coating waste `9aa53a82-5462-400e-9096-efab7718201f`
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_powder_finish.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_powder_finish`

### Process: Configured machinery assembly (`assembly`)

#### Inputs

##### Product flows

###### Steel radial ball bearing (`ball_bearing`)

Record only this specific installed bearing type and mass; do not use a wind-turbine pitch bearing or a bearing cage identity.

- Selected flow: Steel radial ball bearing
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_assembly.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_assembly`

###### Carbon-steel bolt (`fastener`)

Record grade, coating and mass of installed bolts; nuts and washers are separately recorded if present and must not be merged into this bolt row.

- Selected flow: Carbon-steel bolt
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_assembly.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_assembly`

###### Alternating current (`assembly_electricity`)

Meter assembly tools, lifts and attributable local utilities, with the stated purchased supply condition. Include rework attributable to accepted machines.

- Selected flow: Alternating current `3d76981f-964a-4865-b588-0e067a2a1163`
- Flow property / unit: Net calorific value `93a60a56-a3c8-11da-a746-0800200c9a66` / MJ
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_assembly.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_assembly`

###### Finished steel knitting needle cylinder (`needle_cylinder`)

One machined steel needle cylinder with declared diameter, gauge, needle-channel geometry, steel grade and delivered surface/treatment. Include only actual installed steel-cylinder route; cast iron or another material needs its own row. Raw stock is not counted again for a purchased cylinder.

- Selected flow: Finished steel knitting needle cylinder
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_assembly.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_assembly`

###### Finished steel circular-knitting latch needle (`latch_needle`)

One specified finished industrial latch needle with actual gauge, steel grade, finish and mass; collect installed counts and batch mass. Hand-knitting tools, sewing needles and compound needles do not establish this identity.

- Selected flow: Finished steel circular-knitting latch needle
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_assembly.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_assembly`

###### Finished steel circular-knitting sinker (`sinker`)

Identify actual sinker geometry, spring inclusion, grade, coating and delivered local-hardening state. Supplier OL marking supports identifying a locally hardened variant, not a requirement for every sinker. Record count and mass without inferring steel composition.

- Selected flow: Finished steel circular-knitting sinker
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_assembly.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_assembly`
- Sources: `groz-system-parts-2019`

###### Finished steel needle-control cam block (`needle_cam`)

Only a separately supplied actual needle-control cam block, with track, grade and delivered treatment declared. No universal sinker cam box is prescribed: the cited Relanit layout expressly omits one. Do not double count cams included in purchased knitting-head modules.

- Selected flow: Finished steel needle-control cam block
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_assembly.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_assembly`
- Sources: `mayer-relanit-631`

###### Complete positive yarn-feed unit (`positive_feeder`)

One actual delivered feed unit with included wheels, sensors and drive declared. Record installed count and measured unit mass; a complete feeder cannot also receive its included motor/belt inputs.

- Selected flow: Complete positive yarn-feed unit
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_assembly.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_assembly`

###### Finished steel yarn-creel frame (`yarn_creel`)

Only if this physically defined frame belongs to the delivery gate and M. Record dimensions, steel grade, holders/guide inclusion and mass. Customer creels or separately traded accessories outside delivery are excluded. Site fabrication replaces this purchased row with actual stock and operations.

- Selected flow: Finished steel yarn-creel frame
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_assembly.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_assembly`

###### Complete mechanical fabric take-down unit (`fabric_takedown`)

One configured delivered take-down assembly with rollers, gear and motor inclusion specified; record mass and configuration. Separate winding equipment outside the machine gate is not included. Avoid duplicating installed constituent drives.

- Selected flow: Complete mechanical fabric take-down unit
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_assembly.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_assembly`

###### Complete three-phase induction drive motor (`drive_motor`)

Only actual nameplate-confirmed three-phase induction drive motors not contained in other complete modules. Record rating, included enclosure and delivered mass; special-purpose conveyor, wind-turbine or printer motor contexts are not assumed applicable. Different actual motor technology requires a separate row.

- Selected flow: Complete three-phase induction drive motor
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_assembly.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_assembly`

###### Complete motor frequency converter (`inverter`)

One delivered configured converter with actual power rating, board/heatsink/enclosure inclusion and mass. Do not count electronics already in a complete control panel again; operating conversion losses belong to use, except actual factory testing.

- Selected flow: Complete motor frequency converter
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_assembly.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_assembly`

###### Complete circular-knitting electronic control panel (`controller`)

One finished configured machine control panel with included display, boards, sensors and wiring declared. Record measured mass and BOM boundary; embedded electronics are not raw semiconductor exchanges or assumed generic PLCs.

- Selected flow: Complete circular-knitting electronic control panel
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_assembly.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_assembly`
- Sources: `mayer-relanit-631`

###### Finished textile-reinforced rubber drive belt (`drive_belt`)

Only actual supplied belt with confirmed rubber formulation, textile reinforcement, profile and length. Record net mass; metal-chain or polyurethane belts need separate physical/composition-specific rows. Do not duplicate belt included in a complete feeder.

- Selected flow: Finished textile-reinforced rubber drive belt
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_assembly.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_assembly`

###### Finished mineral knitting-needle lubricating oil (`needle_oil`)

Only actual supplier-graded mineral needle/sinker lubricant with declared additives and origin. Weigh fresh issue less unused returns, including attributable test consumption and retained delivery oil; exclude bought modules already filled. Base oil, hydraulic oil and biobased formulations are not substitutes.

- Selected flow: Finished mineral knitting-needle lubricating oil
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_assembly.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_assembly`

### Process: Factory acceptance and net-mass determination (`acceptance`)

#### Inputs

##### Product flows

###### Alternating current (`test_electricity`)

Meter factory knitting trials, alignment, drive/interlocks, tension and take-down checks, with configuration-specific trial yarn, speed, duration and rework. Mill production is excluded. Actual trial energy includes drive and attributable local auxiliaries; no catalogue operational rate becomes a factory amount.

- Selected flow: Alternating current `3d76981f-964a-4865-b588-0e067a2a1163`
- Flow property / unit: Net calorific value `93a60a56-a3c8-11da-a746-0800200c9a66` / MJ
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_acceptance.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_acceptance`

###### Virgin non-textured PET filament test yarn (`test_yarn`)

Only actual factory trials using verified 100% PET fibre non-textured filament yarn; record linear density and supplier finish composition. Weigh net yarn issue minus unused returned yarn, subtracting cone and packaging tare; separately record cloth retained/sold/discarded. Cotton, elastane, textured or blended yarn trials require separate rows, not this identity.

- Selected flow: Virgin non-textured PET filament test yarn
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_acceptance.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_acceptance`

#### Outputs

##### Product flows

###### Knitting machines, stitch-bonding machines, machines for making gimped yarn, tulle, lace, embroidery, trimmings, braid or net and machines for tufting (`finished_machine`)

One kilogram normalizes the same accepted complete configured single-jersey machine. Include actual base/guards, cylinder, needles/sinkers/cams, feeders, drive/control, take-down and declared delivered creel/accessories and retained lubricant. Exclude test yarn/fabric, loose spares, handling fixtures and transport packaging. Declare purchased-module constituents to prevent double counting.

- Selected flow: Knitting machines, stitch-bonding machines, machines for making gimped yarn, tulle, lace, embroidery, trimmings, braid or net and machines for tufting `533238d4-94ee-4db4-8e64-cfe66821248f`
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: 1 kg
- Value mode: `fixed_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_mass`

##### Waste flows

###### Waste PET knitted factory-test fabric (`test_cloth`)

Only segregated discarded PET test fabric transferred as waste, with actual oil/finish/moisture contamination characterized. Weigh waste and document destination; retained or saleable trial fabric is not this waste row and needs its own output and allocation decision. Mixed-fibre wastes remain separate.

- Selected flow: Waste PET knitted factory-test fabric
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_acceptance.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_acceptance`

###### Waste mineral needle lubricating oil (`test_oil_waste`)

Only segregated spent mineral needle lubricant leaving actual factory tests; weigh and characterize water/solid content and destination. Reused/retained oil is not exported waste, and oily textile wipes require their own row.

- Selected flow: Waste mineral needle lubricating oil
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_acceptance.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_acceptance`

### Process: Shipment protection at factory gate (`packaging`)

#### Inputs

##### Product flows

###### Polyethylene film (`pack_film`)

Only when polyethylene film actually accompanies shipment. Weigh film applied and waste separately; it contributes to inventory but not accepted net machine mass.

- Selected flow: Polyethylene film `e64eb06c-6dc9-45f1-b003-3dc6c44b27e2`
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_packaging.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_packaging`

###### Corrugated paperboard protective pad (`pack_board`)

Only where used; record grade, recycled content and mass. A specified fibre-mixture box is not assumed to represent this unspecified protective pad.

- Selected flow: Corrugated paperboard protective pad
- Flow property / unit: Mass `93a60a56-a3c8-11da-a746-0800200b9a66` / kg
- Amount rule: Apply normalize_mass to q_item; reference_mass; cp_packaging.
- Value mode: `calculated_value`
- Specificity: `product_specific`
- Normalization basis: per 1 kg reference flow; collected per one accepted finished machine
- Basis kind: `reference_flow`
- Evidence kind: `calculated_from_collection`
- Collection protocol: `cp_packaging`

## 7. Allocation and Co-product Handling

| rule_id | applies_to | rule | source_ids |
| --- | --- | --- | --- |
| `direct_attribution` | shared_operations | Use job tickets and submetering before allocation. Where a common meter remains, require a measured causal driver such as machine-hours for the identified operation, with all participating jobs and idle load disclosed; divide the attributable quantity by accepted units of the same configuration before mass normalization. | `ghg-product-allocation-2011` |
| `coproduct_decision` | saleable_outputs | Do not assume scrap is a co-product. Disclose destination and legal/product status. If multiple saleable co-products actually occur, seek subdivision; justify a physical relation or, when unavailable, documented economic/other allocation with sensitivity. No universal mass share or avoided-steel credit is prescribed. | `ghg-product-allocation-2011` |
| `rework_scrap` | manufacturing_losses | Retain rework and rejected-unit burdens attributable to the accepted reporting batch. Record recovered internal material once and exported wastes separately. Disclose upstream recycled-content method and any downstream treatment separately to prevent double credits. |  |

## 8. Foreground Data Collection, Calculation, and Quality Rules

### Data Collection Protocols

| protocol_id | process_id | flow_role | record_type | raw_fields | collection_method | unit | frequency | temporal_coverage | site_scope | aggregation_rule | quality_evidence |
| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |
| `cp_mass` | `acceptance` | accepted net mass | weighing | model; configuration; serial number; accepted net mass M | Weigh the accepted complete machine on a calibrated scale, excluding transport packaging; reconcile the same configuration and acceptance record. | kg | each acceptance | complete reporting batch | same model and configuration | accepted net mass per machine | calibration, weighing and signed acceptance records |
| `cp_forming` | `forming` | Stock cutting, forming and machining | meter_and_issue_records | job and configuration; accepted unit count; each row-specific issued/returned amount and original unit; constituent/grade; meter readings; allocation driver; waste destination; route conditions | For each atomic row, use calibrated meters, weighed issue/returns, supplier receipts and disposal tickets. Preserve property: kg for mass, MJ from electricity meters, m3 for directly abstracted groundwater. Purchased-water mass is not converted to volume without measured density and conditions. Reconcile stage utility totals with the factory bill, and component/retained-fluid inclusion with the net-mass record. | row-specific kg, MJ, m3 | each job and meter interval | complete same-configuration batch in reporting period; disclose seasonality and mixed lines | declared factory, outsourced and purchased gates | attributable row amount / accepted machines of the same configuration | calibration, supplier composition, job, allocation and disposal evidence |
| `cp_joining` | `joining` | Structural welding and dressing | meter_and_issue_records | job and configuration; accepted unit count; each row-specific issued/returned amount and original unit; constituent/grade; meter readings; allocation driver; waste destination; route conditions | For each atomic row, use calibrated meters, weighed issue/returns, supplier receipts and disposal tickets. Preserve property: kg for mass, MJ from electricity meters, m3 for directly abstracted groundwater. Purchased-water mass is not converted to volume without measured density and conditions. Reconcile stage utility totals with the factory bill, and component/retained-fluid inclusion with the net-mass record. | row-specific kg, MJ, m3 | each job and meter interval | complete same-configuration batch in reporting period; disclose seasonality and mixed lines | declared factory, outsourced and purchased gates | attributable row amount / accepted machines of the same configuration | calibration, supplier composition, job, allocation and disposal evidence |
| `cp_wet_surface` | `wet_surface` | Aqueous cleaning and preparation | meter_and_issue_records | job and configuration; accepted unit count; each row-specific issued/returned amount and original unit; constituent/grade; meter readings; allocation driver; waste destination; route conditions | For each atomic row, use calibrated meters, weighed issue/returns, supplier receipts and disposal tickets. Preserve property: kg for mass, MJ from electricity meters, m3 for directly abstracted groundwater. Purchased-water mass is not converted to volume without measured density and conditions. Reconcile stage utility totals with the factory bill, and component/retained-fluid inclusion with the net-mass record. | row-specific kg, MJ, m3 | each job and meter interval | complete same-configuration batch in reporting period; disclose seasonality and mixed lines | declared factory, outsourced and purchased gates | attributable row amount / accepted machines of the same configuration | calibration, supplier composition, job, allocation and disposal evidence |
| `cp_powder_finish` | `powder_finish` | Powder application and curing | meter_and_issue_records | job and configuration; accepted unit count; each row-specific issued/returned amount and original unit; constituent/grade; meter readings; allocation driver; waste destination; route conditions | For each atomic row, use calibrated meters, weighed issue/returns, supplier receipts and disposal tickets. Preserve property: kg for mass, MJ from electricity meters, m3 for directly abstracted groundwater. Purchased-water mass is not converted to volume without measured density and conditions. Reconcile stage utility totals with the factory bill, and component/retained-fluid inclusion with the net-mass record. | row-specific kg, MJ, m3 | each job and meter interval | complete same-configuration batch in reporting period; disclose seasonality and mixed lines | declared factory, outsourced and purchased gates | attributable row amount / accepted machines of the same configuration | calibration, supplier composition, job, allocation and disposal evidence |
| `cp_assembly` | `assembly` | Configured machinery assembly | meter_and_issue_records | job and configuration; accepted unit count; each row-specific issued/returned amount and original unit; constituent/grade; meter readings; allocation driver; waste destination; route conditions | For each atomic row, use calibrated meters, weighed issue/returns, supplier receipts and disposal tickets. Preserve property: kg for mass, MJ from electricity meters, m3 for directly abstracted groundwater. Purchased-water mass is not converted to volume without measured density and conditions. Reconcile stage utility totals with the factory bill, and component/retained-fluid inclusion with the net-mass record. | row-specific kg, MJ, m3 | each job and meter interval | complete same-configuration batch in reporting period; disclose seasonality and mixed lines | declared factory, outsourced and purchased gates | attributable row amount / accepted machines of the same configuration | calibration, supplier composition, job, allocation and disposal evidence |
| `cp_acceptance` | `acceptance` | Factory acceptance and net-mass determination | meter_and_issue_records | job and configuration; accepted unit count; each row-specific issued/returned amount and original unit; constituent/grade; meter readings; allocation driver; waste destination; route conditions; trial yarn composition/finish, linear density and mass; trial speed, duration and stitch settings; needle/sinker count/layout; defect inspection; metered auxiliary energy; lubricant issue/returns/retention; trial-fabric fate | For each atomic row, use calibrated meters, weighed issue/returns, supplier receipts and disposal tickets. Preserve property: kg for mass, MJ from electricity meters, m3 for directly abstracted groundwater. Purchased-water mass is not converted to volume without measured density and conditions. Reconcile stage utility totals with the factory bill, and component/retained-fluid inclusion with the net-mass record. Weigh test-yarn issue less unused returns and each separately segregated discarded trial product. Keep actual acceptance criteria and results; no brochure yield or defect limit is assumed. | row-specific kg, MJ, m3 | each job and meter interval | complete same-configuration batch in reporting period; disclose seasonality and mixed lines | declared factory, outsourced and purchased gates | attributable row amount / accepted machines of the same configuration | calibration, supplier composition, job, allocation and disposal evidence |
| `cp_packaging` | `packaging` | Shipment protection at factory gate | meter_and_issue_records | job and configuration; accepted unit count; each row-specific issued/returned amount and original unit; constituent/grade; meter readings; allocation driver; waste destination; route conditions | For each atomic row, use calibrated meters, weighed issue/returns, supplier receipts and disposal tickets. Preserve property: kg for mass, MJ from electricity meters, m3 for directly abstracted groundwater. Purchased-water mass is not converted to volume without measured density and conditions. Reconcile stage utility totals with the factory bill, and component/retained-fluid inclusion with the net-mass record. | row-specific kg, MJ, m3 | each job and meter interval | complete same-configuration batch in reporting period; disclose seasonality and mixed lines | declared factory, outsourced and purchased gates | attributable row amount / accepted machines of the same configuration | calibration, supplier composition, job, allocation and disposal evidence |

### Calculation Rules

| rule_id | Applies to | Formula or rule | Inputs | Output | source_ids |
| --- | --- | --- | --- | --- | --- |
| `normalize_mass` | all inventory rows | q_ref = q_item / M; q_item = exchange amount per one accepted finished machine; q_ref = exchange amount per 1 kg reference flow. | q_item; M; cp_mass | q_ref |  |

The finished_machine output is fixed at 1 kg and is not divided again. Apply the conversion to each other applicable row using the same configuration and batch; quantity numerator units remain unchanged. Mixed configurations must be separated, not averaged by count with a catalogue mass.

### Data Quality Requirements

| requirement_id | Applies to | Requirement | Evidence |
| --- | --- | --- | --- |
| `configuration_trace` | all rows | Trace every input to installed BOM, route and accepted unit; supplier finished parts do not also receive raw-stock burdens. Disclose remaining components as missing coverage until separate atomic records are added. | drawings, BOM, supplier receipts |
| `basis_quality` | cp_mass | M must be positive measured net mass, with the same delivered configuration, fluid state and acceptance gate as all collected exchanges. | calibration and weighing records |
| `coverage_quality` | all processes | Document full batch temporal coverage, meter overlap, rejects, rework, stock changes, outsourced stages and unmeasured emissions. A missing record is unknown, not zero or not_applicable. | ledger, coverage matrix and measurement uncertainty |
| `chemistry_quality` | wet_surface; powder_finish | Verify recipe, concentration and SDS for each supplied formulated chemical; characterize each outgoing waste stream and identify treatment separately from environmental emissions. | recipe, SDS, analyses and transfer tickets |

## 9. Validation Rules

| rule_id | applies_to | rule | source_ids |
| --- | --- | --- | --- |
| `validate_reference` | reference | Reject missing qualifiers, test-yarn-loaded or shipping-gross mass substitution, non-positive M or mismatch between configuration, cp_mass and finished_machine. Require 1 kg output and explicit normalize_mass on every non-reference applicable row. |  |
| `validate_atomic` | inventory | Require one physical exchange per row, verified public identity when supplied, correct property/unit, localized display and medium. Unresolved UUIDs do not authorize proxy substitution or mixed rows. |  |
| `validate_balance` | coverage | Reconcile installed mass, stock, waste, retained fluids and purchased parts using the actual BOM; independently reconcile installed needle/sinker counts and their measured batch mass. Reconcile utilities by stage; internal transfers cancel. Explain differences against recorded measurement uncertainty, without a fabricated numerical tolerance. |  |
| `validate_completeness` | dataset | Check every conditional stage against route evidence. Require missing chemicals, parts, test media and actual emissions to be split and collected before claiming a complete inventory; prohibit cradle-to-gate or service comparisons while upstream or functional coverage is incomplete. |  |
| `validate_allocation` | shared_operations | Require complete driver records and justification for allocation and scrap treatment; document sensitivity where another defensible allocation may change results. | `ghg-product-allocation-2011` |

## 10. Published Dataset Profile

| Field | Value |
| --- | --- |
| dataset_role | Manufacturing foreground process for a configured accepted machine |
| downstream_use | secondary_dataset; background_dataset |
| allowed_use | Input to a declared machinery supply model with identical configuration and disclosed upstream coverage |
| excluded_use | Textile production service, mill operation, or life-cycle comparisons across gauges, sinker layouts and fabric products without separate functional modelling |
| required_metadata | Model, configuration, empty state, M, retained fluids, manufacturer/site, reporting period, process route, voltage/geography, supplier gates, transport/packaging scope and allocation |
| required_quality_disclosure | Measured versus estimated quantities; unresolved identities; unmeasured emissions and components; upstream linkage completeness; uncertainty, data age and configuration limitations |
| update_trigger | Changed needle/sinker layout, diameter/gauge, BOM, coating/lubricant chemistry, test-yarn composition, supplied component, energy mix, acceptance specification or mass protocol |

## 11. Data Sources

| Source id | Type | Reference | Used for |
| --- | --- | --- | --- |
| `mayer-relanit-631` | handbook | Mayer & Cie., Relanit 3.2 HS II, 631/09-24, retained brochure PDF p.1 Application; PDF p.2 features, technical/production table and accessory footnote. https://www.mayercie.com/wp-content/uploads/2024/09/Relanit_3_2_HS_II-631.pdf | Model-specific single-jersey, control and spring-sinker/no-sinker-cam-box architecture; accessory disclaimer. Catalogue fabric yield, efficiency, energy/CO2 and life claims do not establish factory quantities or universal limits. |
| `groz-system-parts-2019` | handbook | Groz-Beckert, System parts for circular knitting machines, Knitting EN 04.2019, PDF p.1 technical features and OL locally hardened sinkers; PDF p.2 system-part examples. https://www.groz-beckert.com/mm/media/en/web/pdf/System_parts_for_circular_knitting_machines.pdf | Historical component identification and local-hardening designation only; no universal steel grade, hardness, process requirement or lifetime. Commercially linked supplier/model evidence is not independent quantitative validation. |
| `ghg-product-allocation-2011` | official_guidance | WRI/WBCSD, Product Life Cycle Accounting and Reporting Standard (2011), chapter9, printed p.63 / PDF p.65, tables9.1–9.2. https://ghgprotocol.org/sites/default/files/standards/Product-Life-Cycle-Accounting-Reporting-Standard_041613.pdf | Historical allocation hierarchy; actual physical-driver evidence needed, no present comprehensive standard-conformance assertion. |